INTEG SERVICES COMPANY LIMITED
Build 3, Room 3, Civil Housing (North), 8 mile, Mayangone Tsp:, Yangon, Myanmar
Tel : + 959 5015564 Email : aphyo.amc@gmail.com
Form work depend on many factors , at the same time you can say a large variety of choices the designer
have.
First of all weight of slab + construction Load 30 psf ( I usually apply )
Spacing of joist due to 12 mm or 16 mm or 20 mm thick Plywood
Arrangement of Tee and / or joist and girder ?
Storey height
For the the case , I am given Ground floor , 8” RC slab
And I decided joist and girder and Tee for RC beam.
Technology is advancing , and new materials .
For the case 12 mm thick Plywood is to be applied ( given )
2’ - 3’ span is okay .
I assume 12 ‘/ 5 = 2.4 ft span
Joist Size ?
For 2.4 ft 130x2.5 = 325 plf
Girder are to be spaced according to Joist size ,
Sat Hollow 3x1 ½” x1.6 mm are available .
Its parameters are
75x45 x1.6 x2.88 kg/m
A=3.672 cm 2
I= 28.4 cm 4
S =13.6 cm3
BM ( working ) = Sx140
= 13.6 x103 x 140
= 1.9 kN-m
BM = 4.743 kN/m xL2/8
1.9 = L2x 4.743 /8
INTEG SERVICES COMPANY LIMITED
Build 3, Room 3, Civil Housing (North), 8 mile, Mayangone Tsp:, Yangon, Myanmar
Tel : + 959 5015564 Email : aphyo.amc@gmail.com
L = 1.8 m
= 6 ft
For beam = 3 ft
For slab = Joist 2.4 ft c/c
Girder = 6ft c/c
Post under beam 3 ft ( 2.4 ft other )
Under slab 6 c/c