The document outlines the functionalities of the UV Basic software, which includes photometry, quantitative analysis, kinetics, wavelength scanning, and DNA/protein analysis. It details various features such as standard curve creation, time scanning options, spectral data display, peak valley search, and dark current detection. Additionally, it describes methods for standard curve fitting and the ability to zoom in/out on spectrum views.

Uploaded by

alan.jr2610
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views1 page

HH 3936

The document outlines the functionalities of the UV Basic software, which includes photometry, quantitative analysis, kinetics, wavelength scanning, and DNA/protein analysis. It details various features such as standard curve creation, time scanning options, spectral data display, peak valley search, and dark current detection. Additionally, it describes methods for standard curve fitting and the ability to zoom in/out on spectrum views.

Uploaded by

alan.jr2610
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Introduction Page 1 of 1

1. Introduction

UV Basic has the main function of Photometry, Quantitative analysis, Kinetics, Wavelength Scanning, Multi-wavelength analysis,
DNA/Protein analysis. Software attached several additional features, for example: spectrum computing(spectrum addition, spectrum
subtraction, spectrum multiplication and spectrum division). spectrum derivative and spectrum compare and so on.

1.1 Main function

Photometry
·Two Test Mode: Absorbancy Data(Abs)/Transition Data(%T) in the custom wavelenth.

Quantitative Analysis
·Create standard curve with calibration standard samples ,or with user setup coefficient method.
·Up to 20 standard samples to the standard calibration curve or directly enter the standard curve coefficient.
·3 methods to standard curve fitting: zero-crossing first-order linear fitting, First-order linear fitting, second-order linear fit).

Time Scan
·Custom scan time interval:0.5 seconds, 1.0 seconds, 2.0 seconds, 5.0 seconds, 10.0 seconds, 30.0 seconds, and 1 Minute.
·2 display mode: Absorbancy Data (Abs), Transition Data (%T).

1.2 Spectra treatment

Spectral data show


·Move the cursor to the spectrum position, the corresponding data will be displayed

Peak valley automatically search


·Automatically search the data peak and valley, and the data will be showed in the peak data list, the corresponding data remark
shown in the picture.

Zoom in/out spectrum view


·Change the X Position/Y Position scale data to zoom in or zoom out the spectrum view.

Dark Current Detect


·Retest the dark current data of instrument.