Elastomer Products
Stand Protectors
Weatherford stand protectors help prevent damage to the pins
                                                                            Advantages of Weatherford
of tubing and casing as these tubular goods are made up in
                                                                                Stand Protectors
stands of doubles and triples.
                                                                          — Prevention of damage to pins
The protectors provide a rugged solution to the weight imposed              of stored tubing and casing.
on the pins and exposure of the tubulars to external damage
and contamination. At the same time, Weatherford stand                    — Protection of stored tubular
                                                                            goods from exposure to
protectors offer flexibility and safety in handling and ease of
                                                                            external damage and
storage. The quick air release close to the rim on the side of the          contamination.
protectors, ensures a high degree of safety as stands are being
moved to the rig floor.                                                   — Enhanced safety of handling
                                                                            tubing and casing.
Based on Weatherford Klepo inflatable technology, the
                              ®
                                                                          — Minimal maintenance.
protectors require minimal maintenance and have a long life
expectancy. Spare valves and tools are included, free of charge,          — Long life expectancy.
with each shipment.
                                                                          — Ease of use.
As an additional service, Weatherford offers stainless steel
offshore containers, complete with certified lift eyes, for
convenient storage of protectors by size. The client and
Weatherford determine dimensions, based on the client's need.
                     Inside                                          Easy                                                   Liquid
                     view                                            deflation                                              tight
                                                                                                                            seal
                                                   Value-driven technology that’s Simply ProductiveSM
                                                                                 © 2005 Weatherford. All rights reserved.   Brochure 611.01
                                                                                                      Elastomer Products
Stand Protectors
Specifications                                                          Material Specification
Sizes
Stand protectors are commercially available in 3 1/2-                                                        Body            Buffer
                                                                                                                                                   Test
through 20-in. sizes. These sizes are suitable for many                                                      (red)           (black)
                                                                                          A
different pin profiles. Additional sizes are available on               Hardness, shore                        85               95            DIN 53505
request. In general, the 9 5/8-, 9 7/8-, 11 3/4-, 11 7/8-,              Tensil strength, N/mm2                 34              40.5           DIN 53504
13 3/8- and 13 5/8-in. sizes can use the same                           Abrasion resistance mm3                75               60            DIN 53516
protector for the various premium connection profiles.                  Compression set %                      3.2             2.3           ASTM D 395A
(One protector is needed for each size.) ABB/Vetco
                                                                        Testing
Gray threads will not fit in the standard stand
protectors.                                                             Weatherford tests materials and performance at
                                                                        parameters that more than twice exceed those
                                                                        expected in deepwater operations. Test reports on
Operation
                                                                        inflation duration, load tests, off-center load tests,
— Inflate with rig air (+/-125 PSI, or 8.5 bar). Do not                 and load tests under temperature are available on
  inflate protectors without tubulars inside. An air gun                request.
  attachment is included with the purchase of stand
  protectors.
— Deflate by hand, as shown in the photo.
— Clean protectors with steam or hot water. Spray
  WD-40®* or equivalent on the valve.
Temperature 149°F (65°C)                Loads up to 44,000 lb (20,000 kg)                 Off-center testing
For more information, prices and delivery, contact Weatherford.
                                                                            *WD-40 is a registered trademark of the WD-40 Company.
                              Elastomers – Main Office
                              Vlaardingen, The Netherlands
                              Phone: 31-10-445-1155
                                                                     Value-driven technology that’s Simply ProductiveSM
                              Fax:    31-10-434-9311
                              email: elastomers@eu.weatherford.com
                                                                               Weatherford products and services are subject to the Company’s standard terms
515 Post Oak Blvd.                                                             and conditions, available on request or at www.weatherford.com. For more
                                                                               information contact an authorized Weatherford representative. Unless noted
Suite 600                     Elastomers Service (US)                          otherwise, trademarks and service marks herein are the property of Weatherford.
Houston, Texas 77027          Houston, Texas, U.S.A.                           Specifications are subject to change without notice.
                              Phone: 713-693-4942
Tel: 713-693-4000             Fax:   713-693-4098
www.weatherford.com           email: elastomers@weatherford.com
                                                                                                        © 2005 Weatherford. All rights reserved.   Brochure 611.01