140 9XXX
140 9XXX
PolyScience
Constant
Temperature
Equipment
Circulators
Remarkably ResponsiveTM
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 2
PolyScience
The Benefits of
PolyScience Refrigerating/Heating
Circulating Baths
Heating
Precise Control Circulating Baths
Controllers to fit every need -
from precise programmable
models to simple analog Immersion Circulators
control for less demanding
applications.
PolyScience is a leading manufacturer Coolers
of Refrigerated Circulators, Heating
Circulators, Chillers, Heat Exchangers,
Water Baths, and custom temperature
control equipment for industrial and
laboratory use. We have been provid-
ing customers worldwide with preci- Easy
sion temperature control equipment Hook
since 1963 and serve a diverse range of Up
industries, including:
• Biotechnology
Easy Set-Up All reservoir models have 1/4 inch NPT internal-
• Chemical
Programmable and Advanced ly threaded inlet and outlet for easy attachment
• Industrial Laser Digital controllers feature to external equipment. Adapters for 3/16, 1/4,
• Medical multi-language help menus and 3/8 inch (.47, .63, and .95 cm) tubing are
• Pharmaceutical to simplify operation and supplied. 240V units also include 1/4 inch x
• Clinical set-up. M16 adapter.
2
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 3
PolyScience Circulators
Table of Contents
Heating Circulators
The 8000 Series, 6L ........................16
The 8100 Series, 13L ......................18
The 8200 Series, 28L ......................20
Model 8306, 28L.............................22
Model 210 Heating Recirculator......23
Exceptional Stability
Advanced refrigeration Immersion Circulators
systems and high wattage Models 7306 and 712 .....................25
heaters respond quickly to
temperature changes for Model 7312.....................................26
ultimate stability. Open Bath Tanks.............................27
Coolers
The KR and VLT Series ....................28
Accessories 30
3
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 4
PolyScience
PolyScience Controllers
Programmable Controller
• Time/Temperature Programming
and Data Logging
• Full Graphic Display with
Multi-Language Help Menus
• 200°C Temperature Control
• Optional Remote Probe Capability
• RS232 Interface Safety Set
Built-in
on the
• Continuously Variable Pump Speed front panel
timer
Control
• Compatible with National Instruments
LabView™, Microsoft® Excel,
and Palm OS®
• Easy-to-Use Select/Set Knob
• Readout in °C or °F
The Programmable Controller
PolyScience Controllers
Advanced Digital, Standard Digital, and Basic
PolyScience
Refrigerating/Heating Circulators
The 9100 Series
Cooling Heating
40˚C 100˚ C
9100 Series
9112, 9102
30˚C
90˚ C
240V Models Applications
80˚ C
20˚C 70˚ C
Calibration
60˚ C
10˚C
50˚ C
9106, 912 Chromatography
240V Models
0 ˚C
40˚ C
Columns
-10˚C 30˚ C 120V Densitometers
Models
20˚ C
-20˚C Distillation
10˚ C
Condensers
-30˚C 0˚ C
0 15 30 45 60 75 90 105 0 5 10 15 20 25 30 35 40
Electrophoresis
Time In Minutes
Apparatus
General Laboratory
Cooling
9100 Series Specifications Isoelectric Focusing
Reservoir Capacity 6 liters Fluids For Below Ambient Work
Polarimeters
+20°C 200 Watts ✔ Select one that satisfies operating conditions,
Cooling Capacity @ 0°C 140 Watts including safety, flash point, and freezing point. Refractometers
-10°C 100 Watts ✔ Pick the lowest possible viscosity.
Rotary Evaporators
Over-Temperature Cutoff Adjustable ✔ Avoid synthetic fluids that are hygroscopic to
Low-Liquid Cutoff Yes prevent ice from forming in the reservoir. Spectrophotometers
Working Access 5 1/4 x 5 1/4 x 5 1/2 in. ✔ Minimize use of mixtures that may change con- Viscometers
lxwxd 13.3 x 13.3 x 14 cm centration due to evaporation.
Supplied with reservoir cover,
Overall Dimensions 15 3/4 x 8 1/4 x 22 1/2 in. ✔ Some mixtures may change from non-flamma- bypass tube, and male inlet/
lxwxh 40 x 21 x 57.1 cm ble to flammable if a volatile component is outlet tubing adapters for 3/8,
1/4
randomly added to keep the freezing point 1/4, and 3/16 inch (.95, .63,
Pump Inlet and Outlet in. FPT Rear Discharge depressed. and .47 cm) tubing. Also
Note: For Cooling Capacity (Watts x 3.41) = BTU/hr. includes 6-ft. (1.83 meter)
standard grounded electrical
cord with U.S. (120V) or
Specifications Model 9112 Model 9102 Model 9106 Model 912 European (240V) plug. Other
country-specific plugs avail-
Temperature Range –20° to 200°C –20° to 200°C –20° to 150°C –20° to 100°C
able; consult PolyScience.
Temperature Stability ± 0.01°C ± 0.01°C ± 0.05°C ± 0.2°C Programmable Model
Controller / RS232 Programmable / Yes Advanced Digital / Yes Standard Digital/ No Basic / No Accessories:
-Remote Probe
Readout Graphic LCD Graphic LCD LED Thermometer (supplied)
(10, 25, or 50-ft.)
Temperature Readout °C or °F °C or °F °C or °F N/A -Digital to Analog Adapter
Readout Accuracy ± 0.25°C ± 0.25°C ± 0.5°C N/A Accessories on pages 30
30 lpm max. (60 Hz) 30 lpm max. (60 Hz) and 31.
Pressure Flow Rate 2-speed, 9 or 15 lpm 2-speed, 9 or 15 lpm
22 lpm max. (50 HZ) 22 lpm max. (50 Hz) www.polyscience.com
22 lpm max. (60 Hz) 22 lpm max. (60 Hz)
Suction Flow Rate
15 lpm max. (50 Hz) 15 lpm max. (50 Hz)
N/A N/A Toll Free: 800-229-7569
USA and Canada
60Hz 1100 Watts 1100 Watts 1100 Watts 1100 Watts
Heater Worldwide: 847-647-0611
50Hz 2200 Watts 2200 Watts 1600 Watts 1600 Watts
Shipping Weight 69 lbs / 31.3 kg 69 lbs / 31.3 kg 66 lbs / 29.9 kg 65 lbs / 29.5 kg Fax: 847-647-1155
Cat. No. 120V, 60Hz, 12A 9112A11B 9102A11B 9106A11B 91A0A11B e-mail:
Cat. No. 240V, 50Hz, 9.9A 9112A12E 9102A12E 9106A12E 91A0A12E
sales@polyscience.com
®
Note: Performance specifications determined at ambient temperature of 20°C/68°F. For 50Hz units, derate cooling capacity by 17%.
7
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 8
PolyScience
Refrigerated/Heating Circulators
The 9000 Series
In applications where bench Advanced Digital Model 9002. Excellent temperature range and stability, combined
space is at a premium, 9000 with the easy-reading, full graphic display and multi-language help menus, make this
Series Circulators can be model suitable for many applications and budgets. The built-in RS232 port comes
placed on a shelf above the standard. The pump is a variable speed pressure/suction (duplex) type for open or
work area while still providing closed loop applications.
convenient eye-level access to Standard Digital Model 9006. Designed for routine use up to 150°C, this model
the controls. And their wide economically delivers the same cooling as our Programmable and Advanced Digital
footprint adds stability for cal- models. The convenient read-and-set LED display plus stability of ±0.05°C meets
ibration work or applications most requirements. Three user-defined temperature buttons offer quick set point
where cart-mounted use is changes for frequently used appications. The pump is 2-speed pressure (simplex) type
desirable. for closed loop applications.
Cooling Heating
20˚C 70˚ C
Calibration
60˚ C
10˚C
50˚ C 9006
Chromatography
0 ˚C
40˚ C
240V Models Columns
-10˚C
30˚ C Densitometers
20˚ C 120V
-20˚C Models Distillation
10˚ C
Condensers
-30˚C 0˚ C
0 15 30 45 60 75 90 105 0 5 10 15 20 25 30 35 40
Electrophoresis
Time In Minutes
Apparatus
General Laboratory
Cooling
9000 Series Specifications
Isoelectric Focusing
Reservoir Capacity 6 liters
Polarimeters
+20°C 200 Watts ✔ For optimum performance locate your
Cooling Capacity @ 0°C 140 Watts circulator on a level surface free from Refractometers
-10°C 100 Watts
drafts and direct sunlight. Rotary Evaporators
Over-Temperature Cutoff Adjustable
✔ Avoid locations where corrosive fumes,
Low-Liquid Cutoff Yes excessive moisture, or excessive dust are Spectrophotometers
present.
Working Access 5 1/4
x 5 1/4
x 5 1/2 in. Viscometers
lxwxd 13.3 x 13.3 x 14 cm ✔ Protect against voltage drops by using
properly grounded power outlets wired Supplied with reservoir cover,
Overall Dimensions 15 3/4 x 18 3/4 x 17 in. bypass tube, and male inlet/
lxwxh 40 x 47.6 x 43.2 cm with 14 gauge or larger diameter wire.
Locate the circulator close to the outlet tubing adapters for 3/8,
Pump Inlet and Outlet 1/4 in. FPT Rear Discharge power outlet. 1/4, and 3/16 inch (.95, .63,
and .47 cm) tubing. Also
Note: For Cooling Capacity (Watts x 3.41) = BTU/hr. includes 6-ft. (1.83 meter)
standard grounded electrical
cord with U.S. (120V) or
Specifications Model 9012 Model 9002 Model 9006 European (240V) plug. Other
Temperature Range -20° to 200°C -20° to 200°C -20° to 150°C country-specific plugs avail-
able; consult PolyScience.
Temperature Stability ±.01°C ±.01°C ±.05°C
Programmable Model
Controller / RS232 Programmable / Yes Advanced Digital / Yes Standard Digital / No Accessories:
Readout Graphic LCD Graphic LCD LED -Remote Probe
(10, 25, or 50-ft.)
Temperature Readout °C or °F °C or °F °C or °F
-Digital to Analog Adapter
Readout Accuracy ± 0.25°C ± 0.25°C ± 0.5°C
Accessories on pages 30
30 lpm max. (60 Hz) 30 lpm max. (60 Hz) and 31.
Pressure Flow Rate 2-speed, 9 or 15 lpm
22 lpm max. (50 Hz) 22 lpm max. (50 Hz)
22 lpm max. (60 Hz) 22 lpm max. (60 Hz)
www.polyscience.com
Suction Flow Rate N/A
15 lpm max. (50 Hz) 15 lpm max. (50 Hz) Toll Free: 800-229-7569
60Hz 1100 Watts 1100 Watts 1100 Watts USA and Canada
Heater
50Hz 2200 Watts 2200 Watts 1600 Watts
Worldwide: 847-647-0611
Shipping Weight 74 lbs / 34 kg 70 lbs / 32 kg 67 lbs / 30.4 kg
Fax: 847-647-1155
Cat. No. 120V, 60Hz, 12A 9012A11B 9002A11B 9006A11B
e-mail:
Cat. No. 240V, 50Hz, 9.9A 9012A12E 9002A12E 9006A12E
sales@polyscience.com
Note: Performance specifications determined at ambient temperature of 20°C/68°F. For 50Hz units, derate cooling capacity by 17%.
®
9
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 10
PolyScience
Refrigerating/Heating Circulators
The 9500 Series
amount of refrigerant needed. greater programming and data logging convenience. The full graphic LCD display and
As a result, it permits fast bath multi-language help menus simplify operation and set-up.
cooling even at high tempera-
tures without excessive energy Advanced Digital Model 9502. Excellent temperature range and stability combined with
consumption. an easy-reading graphic display make this model a fine choice for many applications. The
pump is a powerful variable speed pressure/suction (duplex) type for open or closed loop
To further add to their applica- applications. A built-in RS232 interface comes standard. The full graphic LCD display
tion versatility, Models 9512 and multi-language help menus simplify operation and set-up.
and 9502 feature a powerful
variable speed pressure/suction Standard Digital Model 9506. The same -30°C cooling capacity of our Programmable and
(duplex) pump, making them Advanced Digital models at a price comparable to units with analog controllers make the
ideal for use where continuous, Model 9506 a great value for applications where high heat removal at close to ambient
low-temperature operation is temperature is required. Microprocessor-based controller provides set-and-read functionality;
required or where the viscosity three user-defined temperature buttons make set point changes quick and easy. The 2-speed
of the liquid may affect pressure (simplex) pump is suitable for closed loop applications.
circulation uniformity.
See pages 4 and 5 for additional controller information.
10
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 11
Cooling Heating
100˚ C 9500 Series
40 C
˚ 9512, 9502
90˚ C
240V Models Applications
30 C
˚ 80˚ C
70˚ C
20 C
˚
60˚ C
Low Temperature
10 C 9506
˚ 50˚ C
Calibration
240V Models
0 C 40˚ C
˚ Cloud Point and Pour
30˚ C
-10 C
˚ Point Testing
20˚ C 120V
-20 C
˚ 10˚ C Models Cell Freezing
-30 C
0˚ C
0 10 20 30 40 50 60 70 80 Low Temperature
˚ 0 25 50 75 100 125 150 175
Time In Minutes Reactions
Distillation Condensers
9500 Series Specifications General Laboratory
Reservoir Capacity 13 liters Cooling
+20°C 660 Watts For Best Temperature Control Rotary Evaporators
0°C 480 Watts
Cooling Capacity @
-20°C 240 Watts ✔Use the largest diameter tubing possible Spectrophotometers
-30°C 100 Watts for maximum flow.
Viscosity Studies
Over-Temperature Cutoff Adjustable ✔Insulate the tubing between the circulator
Low-Liquid Cutoff Yes and the application.
✔Choose a fluid with lowest viscosity at the Supplied with reservoir cover,
Reservoir Drain Yes
bypass tube, and male inlet/
Working Access 6 x 11 x 5 1/2 in. selected operating temperature. outlet tubing adapters for 3/8,
lxwxd 14 x 28 x 15.2 cm ✔Select pump speed for optimum fluid mix- 1/4, and 3/16 inch (.95, .63,
ing. This helps assure good uniformity. and .47 cm) tubing. Also
Overall Dimensions 17 x 15 1/2 x 24 3/4 in.
includes 6-ft. (1.83 meter)
lxwxh 43 x 39.4 x 62.9 cm
✔Keep reservoir covered. standard grounded electrical
Pump Inlet and Outlet 1/4 in. FPT Rear Discharge cord with U.S. (120V) or
✔Consider the use of a remote probe. European (240V) plug. Other
Note: For Cooling Capacity (Watts x 3.41) = BTU/hr. country-specific plugs avail-
able; consult PolyScience.
Specifications Model 9512 Model 9502 Model 9506 Programmable Model
Temperature Range -30° to 200°C -30° to 200°C -30° to 150°C Accessories:
Temperature Stability ± 0.01°C ± 0.01°C ± 0.05°C
-Remote Probe
(10, 25, or 50-ft.)
Controller / RS232 Programmable / Yes Advanced Digital / Yes Standard Digital / No -Digital to Analog Adapter
Readout Graphic LCD Graphic LCD LED Accessories on pages 30
Temperature Readout °C or °F °C or °F °C or °F and 31.
Readout Accuracy ± 0.25°C ± 0.25°C ± 0.5°C
30 lpm max. (60 Hz) 30 lpm max. (60 Hz) www.polyscience.com
Pressure Flow Rate 2-speed, 9 or 15 lpm
22 lpm max. (50 Hz) 22 lpm max. (50 Hz)
Toll Free: 800-229-7569
22 lpm max. (60 Hz) 22 lpm max. (60 Hz)
Suction Flow Rate
15 lpm max. (50 Hz) 15 lpm max. (50 Hz)
N/A USA and Canada
60Hz 1100 Watts 1100 Watts 1100 Watts Worldwide: 847-647-0611
Heater
50Hz 2200 Watts 2200 Watts 1600 Watts Fax: 847-647-1155
Shipping Weight 136 lbs / 61.7 kg 134 lbs / 60.8 kg 130 lbs / 59.0 kg
e-mail:
Cat. No. 120V, 60Hz, 13A 9512A11C 9502A11C 9506A11C sales@polyscience.com
Cat. No. 240V, 50Hz, 9.8A 9512A12E 9502A12E 9506A12E
®
Note: Performance specifications determined at ambient temperature of 20°C/68°F. For 50Hz units, derate cooling capacity by 17%.
11
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 12
PolyScience
Refrigerating/Heating Circulators
The 9700 Series
• -40°C Cooling
Capability
• 13 Liter Reservoir
• Broad Operating
Temperature Range
• Ample Reservoir for
Sample Immersion
• Cool Command™
Refrigeration System
• Enlarged Access Opening
• Easy-Access Reuseable
Filter
ture stability. The Model 9706 offer even greater programming and data logging convenience. The full graphic LCD
features a temperature range of display with multi-language help menus aid in operation and set-up.
-40° to 150°C with ±0.05°C
Advanced Digital Model 9702. Excellent temperature range and stability combined with
stability. All models feature our
easy-reading graphic display make this model a fine choice for many applications and
Cool Command refrigeration
budgets. A built-in RS232 interface comes standard. The pump is a powerful variable
system and fuzzy logic energy
speed pressure/suction (duplex) type for open or closed loop applications. The full graphic
management technique to
LCD display with multi-language help menus simplify operation and set-up.
deliver up to 50% greater energy
efficiency than traditional sys- Standard Digital Model 9706. A -40°C cooling capacity and +150°C upper temperature
tems. This advanced technolo- limit make this circulator an economical choice for applications where high heat removal
gy carefully monitors heat load at close to ambient temperatures is required. Microprocessor-based controller provides
to deliver only the amount of set-and-read functionality; three user-defined temperature buttons make set point
refrigerant needed. As a result, changes quick and simple. The 2-speed pressure (simplex) pump is suitable for closed
it permits fast bath cooling loop applications.
even at high temperatures
without excessive energy con-
sumption.
See pages 4 and 5 for additional controller information.
12
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 13
Cooling Heating
PolyScience
Refrigerating/Heating Circulators
The 9600 Series
All 9600 Series models also drivers and Excel® macros provide even greater programming and data logging conven-
feature our Cool Command ience. A full graphic LCD display with multi-language help menus simplify operation and
refrigeration system and fuzzy set-up.
logic energy management tech-
Advanced Digital Model 9602. A fine choice for more modest applications and budgets,
nique to deliver up to 50%
the 9602 features -25°C to +150°C temperature control, a powerful variable speed pres-
greater energy efficiency than
sure/suction (duplex) pump for open or closed loop applications, and integral RS232
traditional systems. This
interface. A full graphic LCD display with multi-language help menus simplify operation
advanced technology carefully
and set-up.
monitors heat load to deliver
only the amount of refrigerant Standard Digital Model 9606. The most economical model in this series, the 9606 offers
needed. As a result, it permits the same temperature range and cooling capacity as our more full-featured models. A
fast bath cooling even at high microprocessor-based controller provides set-and-read functionality; three user-defined
temperatures without excessive temperature buttons make set point changes quick and simple. The 2-speed pressure
energy consumption. (simplex) pump is suitable for closed loop applications.
Cooling Heating
PolyScience
Heating Circulators
The 8000 Series
• Above Ambient
Temperature Control
• 6 Liter
• Small Footprint,
Low Profile
• Choice of
Microprocessor or
Analog Controller
For even greater operational Excel® macros provide even greater programming and data logging convenience. A full
flexibility, a variety of acces- graphic LCD display and multi-language help menus simplify operation and set-up.
sories and add-ons are also
available for 8000 Series Advanced Digital Model 8002. A fine choice for more modest applications and budgets, the
Circulators. Our tap water 8002 features the same temperature range and stability as the 8012 as well as a full graphic
cooling coil (Cat. No. 060300; LCD display with multi-language help menus. Other standard features include a powerful
page 30) allows operation at variable speed pressure/suction (duplex) pump for open or closed loop applications and integral
temperatures closer to ambient RS232 interface.
and provides more rapid cool- Standard Digital Model 8006. The most economical microprocessor-controlled model in
down from elevated tempera- this series, the 8006 has an upper temperature limit of 150°C and a bright set-and-read LED
tures. And for below ambient display. Three user-defined temperature buttons make set point changes quick and simple.
work, our KR60 Flow-Through The 2-speed pressure (simplex) pump is suitable for closed loop applications.
Cooler (page 28) can be
added to provide cooling Basic Model 812. The lowest priced Heating Circulator in the 8000 Series, the 812 is ideal
down to -25°C. for use in applications where set point changes are infrequent. Temperature is set via a rotary
dial and is read on a supplied alcohol thermometer. The 2-speed pressure (simplex) pump is
suitable for closed loop applications.
Heating
Kinetic Research
Polymer Studies
Petroleum Testing
8000 Series Specifications
Temperature Gradients
Reservoir Capacity 6 liters
High Temperature Precautions: Spectrophotometers
Over-Temperature Cutoff Adjustable
✔ Select a fluid with a flash point well
Low-Liquid Cutoff Yes above the operating temperature. Viscosity Studies
Working Access 5 1/4 x 5 1/4 x 5 1/2 in. Supplied with reservoir cover,
✔ Silicone oils are preferred over mineral
lxwxd 13.3 x 13.3 x 14 cm bypass tube, and male inlet/
oil which may smoke or burn.
Overall Dimensions 14 1/4 x 8 1/4 x 14 in. outlet tubing adapters for 3/8,
lxwxh 37.5 x 21 x 35.6 cm ✔ Place circulator in a fume hood if 1/4, and 3/16 inch (.95, .63,
noxious vapors may be present. and .47 cm) tubing. Also
Pump Inlet and Outlet 1/4 in. FPT Rear Discharge includes 6-ft. (1.83 meter)
✔ Use high temperature tubing and tub- standard grounded electrical
ing adapters. See page 30 for acces- cord with U.S. (120V) or
sories. European (240V) plug. Other
country-specific plugs avail-
Specifications Model 8012 Model 8002 Model 8006 Model 812 able; consult PolyScience.
Temperature Range Ambient +5° to 200°C Ambient +5° to 200°C Ambient +5° to 150°C Ambient +5° to 100°C Programmable Model
Accessories:
Temperature Stability ±0.01°C ±0.01°C ±0.05°C ±0.2°C
-Remote Probe
Controller / RS232 Programmable / Yes Advanced Digital / Yes Standard Digital / No Basic / No (10, 25, or 50-ft.)
Readout Graphic LCD Graphic LCD LED Thermometer (supplied) -Digital to Analog Adapter
Readout Accuracy ±0.25°C ±0.25°C ±0.5°C N/A Accessories on pages 30
and 31.
Temperature Readout °C or °F °C or °F °C or °F N/A
30 lpm max. (60 Hz) 30 lpm max. (60 Hz)
Pressure Flow Rate 2-speed, 9 or 15 lpm 2-speed, 9 or 15 lpm
22 lpm max. (50 Hz) 22 lpm max. (50 Hz)
22 lpm max. (60 Hz) 22 lpm max. (60 Hz) www.polyscience.com
Suction Flow Rate N/A N/A
15 lpm max. (50 Hz) 15 lpm max. (50 Hz) Toll Free: 800-229-7569
Heater
60Hz 1100 Watts 1100 Watts 1100 Watts 1100 Watts USA and Canada
50Hz 2200 Watts 2200 Watts 1600 Watts 1600 Watts
Worldwide: 847-647-0611
Shipping Weight 25 lbs / 11.3 kg 25 lbs / 11.3 kg 22 lbs / 9.8 kg 22 lbs / 9.8 kg
Cat. No. 120V,
Fax: 847-647-1155
8012A11B 8002A11B 8006A11B 80A0A11B
50/60Hz, 11A e-mail:
Cat. No. 240V, sales@polyscience.com
8012A12E 8002A12E 8006A12E 80A0A12E
50/60Hz, 9.8A
®
Note: Performance specifications determined at ambient temperature of 20°C/68°F.
17
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 18
PolyScience
Heating Circulators
The 8100 Series
• Above Ambient
Temperature Control
• 13 Liter Reservoir
• Large Reservoir Opening
• Small Footprint, Low
Profile
• Carrying Handles For
Easy Placement
Heating
100˚ C
8112, 8102
8100 Series
90˚ C 240V Models Applications
80˚ C
70˚ C
60˚ C
Aging Studies
50˚ C
8106
240V Models
Calibration
40˚ C
30˚ C Densitometers
20˚ C 120V If you operate above 90°C, be aware of Extractor - Concentrators
Models
10˚ C the following:
DNA Melting Curves
0˚ C
0 10 20 30 40 50 60 70 80 ✔ Heat loss from vapor may cause poor
Time In Minutes temperature stability. Enzyme Assays
✔ Use a cover and floating hollow balls Kinetic Research
to help prevent heat and vapor loss.
Polymer Studies
✔ Fluid lost from vapor will have to be
frequently replenished. Petroleum Testing
✔ If fluid other than water is used, a Temperature Gradients
8100 Series Specifications
fume hood may be required to prevent Spectrophotometers
Reservoir Capacity 13 liters
the buildup of vapors inside the room.
Over-Temperature Cutoff Adjustable Viscosity Studies
Low-Liquid Cutoff Yes
Working Access 51/4 x 81/2 x 73/4 in. Supplied with reservoir cover,
lxwxd 13.3 x 21.6 x 19.7 cm bypass tube, and male inlet/
Overall Dimensions 15 1/2 x 10 7/8 x 14 3/4 in.
outlet tubing adapters for 3/8,
lxwxh 39.4 x 27.6 x 37.5 cm
1/4, and 3/16 inch (.95, .63,
and .47 cm) tubing. Also
Pump Inlet and Outlet 1/4 in. FPT Rear Discharge includes 6-ft. (1.83 meter)
standard grounded electrical
cord with U.S. (120V) or
European (240V) plug. Other
country-specific plugs avail-
able; consult PolyScience.
Specifications Models 8112 Models 8102 Models 8106
Programmable Model
Temperature Range Ambient +5° to 150°C Ambient +5° to 150°C Ambient +5° to 150°C Accessories:
Temperature Stability ±0.01°C ±0.01°C ±0.05°C -Remote Probe
Controller / RS232 Programmable / Yes Advanced Digital / Yes Standard Digital / No
(10, 25, or 50-ft.)
-Digital to Analog Adapter
Readout Graphic LCD Graphic LCD LED
Accessories on pages 30
Readout Accuracy ±0.25°C ±0.25°C ±0.5°C and 31.
Temperature Readout °C or °F °C or °F °C or °F
30 lpm max. (60 Hz) 30 lpm max. (60 Hz)
Pressure Flow Rate
22 lpm max. (50 Hz) 22 lpm max. (50 Hz)
2-speed, 9 or 15 lpm www.polyscience.com
22 lpm max. (60 Hz) 22 lpm max. (60 Hz) Toll Free: 800-229-7569
Suction Flow Rate N/A
15 lpm max. (50 Hz) 15 lpm max. (50 Hz) USA and Canada
60Hz 1100 Watts 1100 Watts 1100 Watts Worldwide: 847-647-0611
Heater
50Hz 2200 Watts 2200 Watts 1600 Watts
Fax: 847-647-1155
Shipping Weight 40 lbs / 18 kg 32 lbs / 14.5 kg 28 lbs / 12.7 kg
Cat. No. 120V, 50/60Hz, 11A 8112A11B 8102A11B 8106A11B
e-mail:
sales@polyscience.com
Cat. No. 240V, 50/60Hz, 9.8A 8112A12E 8102A12E 8106A12E
®
Note:Performance specifications determined at ambient temperature of 20°C/68°F.
19
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 20
PolyScience
• Above Ambient
Temperature Control
• 28 Liter Reservoir
• Large Reservoir Opening
• Compact Design
• Carrying Handles
For Easy Placement
100˚ C
Reservoir Capacity 28 liters 8200 Series
90˚ C
8212, 8202
240V Models
Over-Temperature Cutoff Adjustable Applications
80˚ C Low-Liquid Cutoff Yes
70˚ C Working Access 121/8 x 103/8 x 8 in. Calibration
60˚ C lxwxd 30.8 x 26.4 x 20.3 cm
50˚ C 8206 Overall Dimensions 22 3/4 x 13 3/16 x 14 3/4 in. Chromatography
40˚ C
240V Models lxwxh 55.8 x 33.5 x 37.5 cm Columns
Pump Inlet and Outlet 1/4 in. FPT Rear Discharge
30˚ C Densitometers
20˚ C
120V Distillation
10˚ C Models Condensers
0˚ C ®
0 25 50 75 100 125 150 175 200
Electrophoresis
Time In Minutes
Apparatus
Specifications Models 8212 Models 8202 Models 8206 General Laboratory
Temperature Range Ambient +5° to 150°C Ambient +5° to 150°C Ambient +5° to 150°C Isoelectric Focusing
Temperature Stability ±0.01°C ±0.01°C ±0.05°C
Polarimeters
Controller / RS232 Programmable / Yes Advanced Digital / Yes Standard Digital / No
Refractometers
Readout Graphic LCD Graphic LCD LED
Readout Accuracy ±0.25°C ±0.25°C ±0.5°C Rotary Evaporators
Temperature Readout °C or °F °C or °F °C or °F Spectrophotometers
30 lpm max. (60 Hz) 30 lpm max. (60 Hz) Viscometers
Pressure Flow Rate 2-speed, 9 or 15 lpm
22 lpm max. (50 Hz) 22 lpm max. (50 Hz)
22 lpm max. (60 Hz) 22 lpm max. (60 Hz)
Suction Flow Rate N/A
15 lpm max. (50 Hz) 15 lpm max. (50 Hz)
60Hz 1100 Watts 1100 Watts 1100 Watts
Heater
50Hz 2200 Watts 2200 Watts 1600 Watts
Shipping Weight 50 lbs / 23 kg 43 lbs / 19.5 kg 40 lbs / 18.1 kg
Cat. No. 120V, 50/60hz, 11A 8212A11B 8202A11B 8206A11B
Cat. No. 240V, 50/60Hz, 9.8A 8212A12E 8202A12E 8206A12E
Note: Performance specifications determined at ambient temperature of 20°C/68°F.
Supplied with reservoir cover, bypass tube, and male inlet/outlet tubing adapters for 3/8, 1/4, and 3/16 inch (.95,
.63, and .47 cm) tubing. Also includes 6-ft. (1.83 meter) standard grounded electrical cord with U.S. (120V) or
European (240V) plug. Other country-specific plugs available; consult PolyScience.
21
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 22
PolyScience
Model 8306
Model 8306
Features
• Easy-to-Use
Microprocessor
Controller
• Three Preset
Temperatures Buttons
Permit Rapid
Temperature Set Point
Changes
• 28 Liters
• External Circulation
Capability
• Hinged, See-Through
Cover
See page 5 for additional information on the Standard Controller used on the Model 8306.
22
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 23
Model 8306
The Model 8306
Applications
Model 8306
23
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 24
PolyScience
Immersion Circulators
The 7000 Series
7000 Series
Features
Model 712
24
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 25
Choice of Controller
Selectable Pump Speed
Bacteriological
Incubation
Calibration
Cell Culture
Enzyme Assays
Kinetic Research
Tempering Samples
Thawing Frozen
Specimens
Warming Culture
Media
* Temperature range and stability may vary depending on bath volume, surface area, insulation and
type of fluid.
See page 5 for additional controller information. Note: Performance specifications determined at ambient temperature of 20°C/68°F.
25
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 26
PolyScience
Programmable Controller
The 7000 Series
Model 7312
Model 7312 shown here in the 21 liter
Features acryllic tank. See page 27
for tank information.
• Time/Temperature
Programmability
• Variable Speed Pump
• Controllable Through
RS232 Interface
• RS232 Cable Supplied
• Remote Probe Capability
Supplied with male inlet/
outlet tubing adapters for 3/8,
1/4, and 3/16 inch (.95, .63, and
.47 cm) tubing. Also includes 6-ft.
(1.83 meter) standard grounded
electrical cord with U.S. (120V)
or European (240V) plug. Other
country-specific plugs available;
consult PolyScience.
Accessories on pages 30 and 31.
®
Open Baths
Acrylic Bath Stainless Steel Bath These open baths are recommended
for use with PolyScience Immersion
Circulators or where a container
with the corrosion resistance of
stainless steel or visibility of clear
acrylic or polycarbonate is needed.
Polycarbonate Bath
Acrylic Open Baths. Provide good visibility of immersed samples, never rust,
and cost less than stainless steel baths. The upper working limit of these acrylic
baths is 70°C. The bottoms are elevated 21/8 in. (5.4 cm) to allow placement
of low-profile magnetic stirrers or other devices beneath the bath.
Stainless Steel Baths. Seamless, insulated, and coated with a durable epoxy
powder finish. Carrying handles included. These baths can be used for fluid
temperatures up to 300°C.
Polycarbonate Bath. Provides a broad working temperature range (-40° to
+98°C). Stackable design fits standard racks and carts.
PolyScience
PolyScience Coolers
The KR and VLT Series
• Continuous Cooling
to Temperatures as Low
as -100˚C
• Choice of Fixed or
Adjustable Set Point
• Low-Cost Operation -
An Economical
Alternative to Dry Ice PolyScience VLT and KR Series Coolers can be used to achieve low-temperature capability with non-refrigerated
or Liquid Nitrogen circulators or boost the cooling capacity of refrigerated circulators.
• Designed For VLT Series Coolers are available with immersion probes only. They are capable of achieving cooling temperatures
Continuous Use as low as -100°C. VLT 100 models feature a digital temperature display and may be ordered with or without
temperature control; non-temperature controlled models operate at maximum cooling. The VLT 60 also operates
at maximum cooling (-60°C). It does not display temperature.
KR Series Coolers are available in both immersion probe and flow-through models. They are capable of achieving
cooling temperatures as low as -45°C. All KR models are designed to run at maximum cooling; temperature
control must be provided by an external circulator. The flow-through model must be used in-line with a circula-
tor pump. Because of its high cooling efficiency, an anti-freeze solution is required in the circulating system.
Immersion Probe style coolers (VLT Series, KR 50, and KR 80) are excellent for trapping and Dewar type
applications and can be used to reduce the expense of using dry ice or liquid nitrogen. PolyScience offers
several different styles of immersion probes; all have an insulated flexible hose that allows convenient
placement of the cooling probe.
28
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 29
0˚C
-70˚ C
10˚C
Cooling Exothermic
VLT 100 0˚C -10˚C Reactions
-80˚ C VLT60
-10˚C -20˚C
Freezing Point
KR50
-90˚ C
-20˚C -30˚C Determinations
KR80 KR60
-100˚ C -30˚C -40˚C
0 15 30 45 60 75 90 105
Impact Testing
0 5 10 15 20 25 30 35 40 0 10 20 30 40 50 60 70
Time In Minutes
Lyophilization
Note: Test data represents 3 liters of 50% water, 50% ethylene glycol mixture. Quick Cooling
Replace Dry ice
VLT Series Specifications VLT 100 VLT 100-NC VLT 60
Temperature Control Yes No No Solvent Traps
Temperature Range -40° to -85°C -40° to -100°C -20° to -60°C Vacuum Traps
Temperature Readout Digital Display None
150 watts @ -40°C
75 watts @ -20°C
Cooling Capacity 120 watts @ -60°C
0 watts @ -60°C
70 watts @ -80°C
Compressor Two; 1/2 HP each One; 1/4 HP VLT and KR Series Coolers
Overall Dimensions 21 x 15 x 20.125 in. 9 x 10 x 11 in. supplied with 6-ft. (1.83
(H x W x D) 53.3 x 38.1 x 51.1 cm 22.9 x 25.4 x 22.9 cm meter) standard grounded
Shipping Weight (Approximate) 162 lbs./ 73.5 kg 49 lbs./22 kg electrical cord with U.S.
Standard Cooling Probe 3 in. Rigid Coil 1.5 in. Rigid Coil (120V) or European (240V)
plug. Other country-specific
Optional Cooling Probes Cold Finger None
Flexible
plugs available; consult
PolyScience. KR 60 Flow-
Electrical 120 V, 60 Hz, 11.5A 120 V, 60 Hz, 5A
240 V, 50 Hz, 7.5A 240 V, 50 Hz, 2.5A Through Coolers supplied
3 in. Rigid Coil - P85C6A101B 3 in. Rigid Coil - P10N6A101B with 3/8 inch male adapters
Cat. No. / Probe Style with 1/2 inch barbed hose
(120V) Cold Finger - P85C8A101B Cold Finger - P10N3A101B 1.5 in. Rigid Coil - 070960
Flexible - P85C4A101B Flexible - P10N4A101B connector.
Cat. No. / Probe Style 3 in. Rigid Coil - P85C6A102E 3 in. Rigid Coil - P10N6A102E Accessories on pages 30
(240V) Cold Finger -P85C8A102E Cold Finger - P10N3A102E 1.5 in. Rigid Coil - 070965
Flexible - P85C4A102E Flexible - P10N4A102E and 31.
PolyScience
Accessories
Insulation
8 mm tubing per yard (.9m) Cat. No. 060309
13 mm tubing per yard (.9m) Cat. No. 060311
30
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 31
Accessories
Accessories
Digital-to-Analog Adapter Glass Thermometer (non-mercury)
For circulators with Programmable or Advanced -20° to 150°C, 1°C Cat. No. 099590
Digital Controller when direct digital control is
not required. Connects to the RS232 port and pro- Concentrated Bath Cleaner
vides 10mv/degree analog signal for external
monitoring or control. A concentrated liquid for
cleaning and removing rust and
Cat. No. 062120
mineral deposits from stainless
steel and plastic baths. Use at
Lab Algicide elevated temperatures. Helps
General purpose lab algicide remove existing algae prior to
helps keep water baths clean, treatment with Lab Algicide. 1
odor free, and resistant to black oz. (29.6 ml) treats approxi-
algae. Stainless steel compati- mately 2 gallons (8 liters).
ble. Use 20 drops per gallon to
prevent algae growth. 8 oz. (236 8 oz. bottle Cat. No. 004-300050
ml) dispenser bottle treats 16 oz. bottle Cat. No. 004-300052
approximately 200 gallons (757
liters).
8 oz. bottle Cat. No. 004-300040
Bath Fluids
Low Temperature - Dynalene HC-50™ combines the low-temperature
performance of synthetic organic and silicone fluids while extending the
properties of familiar aqueous-based glycols. Excellent low-temperature per-
formance without toxicity or risk to the environment, equipment, or personnel.
High Temperature - Dow Corning® Silicone Heat Transfer Fluids provide
superior thermal stability over their temperature ranges. Check bath
system compatibility before using. Compatible with stainless steel; not com-
patible with Buna or natural rubber.
Temperature Freeze
Range Point Viscosity Quantity Cat. No.
Dynalene HC™ -53° to 60°C -56°C 3.6 cSt @ 0°C 1 gallon 060330
-63° to 140°F -68°F 15.1 cSt @ -40°C 3.79 liters
Dow Corning® 510 50° to 150°C -70°C 50 cSt @ 25°C 1 gallon 060326
www.polyscience.com
122° to 302°F -94°F 3.79 liters
Toll Free: 800-229-7569
Dow Corning® 550 100° to 200°C -50°C 125 cSt @ 25°C 1 gallon 060327
USA and Canada
212° to 392°F -58°F 3.79 liters
Worldwide: 847-647-0611
Dow Corning® 710 150° to 250°C -22°C 500 cSt @ 25°C 1 gallon 060328
302° to 482°F -7.6°F 3.79 liters Fax: 847-647-1155
Due to high viscosity, Silicone Fluids 510, 550, and 710 are not recommended for use below 90°C. e-mail:
Dow Corning fluids are produced by and registered TMs of Dow Corning Corporation. sales@polyscience.com
Dynalene HC is a registered TM of Advanced Fluid Technologies, Inc.
31
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 32
www.polyscience.com
PolyScience offers six models of PolyScience chillers have a new PolyScience offers the new
water baths with either digital Noise Reduction Technology DURACHILL™ line of Industrial
or analog control. Shaking that offers quiet but powerful Capacity Chillers. They provide
water bath systems are also cooling operation. Compact and high performance cooling even
available portable, they are ideal for a in high ambient conditions.
wide range of laboratory and
industrial cooling applications.