0% found this document useful (0 votes)
186 views32 pages

140 9XXX

PolyScience is a manufacturer of temperature control equipment, including Refrigerated Circulators and Heating Circulators, serving various industries since 1963. Their products feature precise control, easy setup, and advanced refrigeration technology to ensure stability and efficiency. The document outlines different models and controllers available, emphasizing their applications in laboratory and industrial settings.

Uploaded by

Josefina Reyes
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
186 views32 pages

140 9XXX

PolyScience is a manufacturer of temperature control equipment, including Refrigerated Circulators and Heating Circulators, serving various industries since 1963. Their products feature precise control, easy setup, and advanced refrigeration technology to ensure stability and efficiency. The document outlines different models and controllers available, emphasizing their applications in laboratory and industrial settings.

Uploaded by

Josefina Reyes
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 32

21238_GRAP_Circulator_A3:CirculatorR1.

qxd 3/2/09 2:48 PM Page 33

PolyScience
Constant
Temperature
Equipment

Circulators
Remarkably ResponsiveTM
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 2

PolyScience

The Benefits of

PolyScience Refrigerating/Heating
Circulating Baths

Heating
Precise Control Circulating Baths
Controllers to fit every need -
from precise programmable
models to simple analog Immersion Circulators
control for less demanding
applications.
PolyScience is a leading manufacturer Coolers
of Refrigerated Circulators, Heating
Circulators, Chillers, Heat Exchangers,
Water Baths, and custom temperature
control equipment for industrial and
laboratory use. We have been provid-
ing customers worldwide with preci- Easy
sion temperature control equipment Hook
since 1963 and serve a diverse range of Up
industries, including:
• Biotechnology
Easy Set-Up All reservoir models have 1/4 inch NPT internal-
• Chemical
Programmable and Advanced ly threaded inlet and outlet for easy attachment
• Industrial Laser Digital controllers feature to external equipment. Adapters for 3/16, 1/4,
• Medical multi-language help menus and 3/8 inch (.47, .63, and .95 cm) tubing are
• Pharmaceutical to simplify operation and supplied. 240V units also include 1/4 inch x
• Clinical set-up. M16 adapter.

Beyond our comprehensive line of


standard temperature control products,
PolyScience also offers custom
designed heating and cooling equip- Cool Command
ment. If you have a special application
or specific product need, our experi- TM
Refrigeration Technology
enced design, engineering, and techni- •Rapid Cool Downs at Elevated Temperatures
cal staff will be happy to review your •Ultra-Precise Cooling Control
application and design a product that •Longer Compressor Life
meets your exact requirements.
Prevent Condensation Cool Command is an advanced refrigeration
A reservoir purge tube port technology that carefully monitors heat load to
allows the injection of inert deliver only the amount of refrigerant needed.
gas into the bath's reservoir As a result, it permits fast bath cooling even at
to prevent condensation high temperatures without excessive energy
build-up. consumption.
ISO 9001:2000 Certified

2
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 3

PolyScience Circulators

Table of Contents

Circulator Controller Choices...........4


Refrigerating/Heating Circulators
Selectable Flow Rates The 9100 Series, 6L ..........................6
Pressure and suction pumps
The 9000 Series, 6L ..........................8
on programmable and digital
models provide variable The 9500 Series, 13L ......................10
flow rates for both open and
The 9700 Series, 13L ......................12
closed applications.
The 9600 Series, 28L ......................14

Heating Circulators
The 8000 Series, 6L ........................16
The 8100 Series, 13L ......................18
The 8200 Series, 28L ......................20
Model 8306, 28L.............................22
Model 210 Heating Recirculator......23
Exceptional Stability
Advanced refrigeration Immersion Circulators
systems and high wattage Models 7306 and 712 .....................25
heaters respond quickly to
temperature changes for Model 7312.....................................26
ultimate stability. Open Bath Tanks.............................27

Coolers
The KR and VLT Series ....................28

Accessories 30

Lasting Durability www.polyscience.com


Stainless steel wetted parts Toll Free: 800-229-7569 USA and Canada
and reservoirs fight corrosion. Worldwide: 847-647-0611
Tough epoxy powder coated
Fax: 847-647-1155
exteriors clean easily.
e-mail: sales@polyscience.com

3
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 4

PolyScience

PolyScience Controllers
Programmable Controller

Full graphic One-touch


Programmable display Select/Set Knob
Controller

• Time/Temperature Programming
and Data Logging
• Full Graphic Display with
Multi-Language Help Menus
• 200°C Temperature Control
• Optional Remote Probe Capability
• RS232 Interface Safety Set
Built-in
on the
• Continuously Variable Pump Speed front panel
timer
Control
• Compatible with National Instruments
LabView™, Microsoft® Excel,
and Palm OS®
• Easy-to-Use Select/Set Knob
• Readout in °C or °F
The Programmable Controller

The PolyScience Programmable Controller offers the greatest number of features


Set preference plus the simplicity of a one-touch, multi-function, Select/Set knob.
parameters with
multi-language The multi-language LCD graphic readout simultaneously displays your set point and
help menus. actual fluid temperature. The built-in timer provides visual and audible indications
of timed events. The display also lets you know when it's time for calibration or
Time/temperature service to insure accuracy and eliminate downtime.
programming by PC Time/temperature programs can be set directly by the controller's Select/Set knob.
or by the controller's Ten programs can be stored in the controller's memory, each having up to 50 steps
Select/Set knob. that can be cycled up to 99 times.
An RS232 interface is standard. Data logging can be viewed from the graphic
Temperature trends
display or via your PC. Included software supports National Instruments
on the controller's
LabView™, Microsoft® Excel, and Palm® OS.
display with real-
time graphing. Remote probe capability is one of the strongest reasons for choosing the
Programmable Controller. The optional probe can take over temperature control
Select internal at the point of application, such as in a remote bath. Temperature shifts due to
probe or external heat loss along tubing lines are eliminated and accuracy is maintained.
probe to optimize Programmable units are accurate to ±0.25°C, and stable to ±0.01°C. The micro-
control. processor controller can be tuned to optimize PID performance for
various fluids and volumes. User-adjustable high and low temperature limits and
Set high and low alarms are stored in non-volatile memory. A redundant safety thermostat protects
limits with ease. over-temperature and low-liquid situations. On-demand automatic refrigeration
Audible alarm control is standard on all refrigerated programmable units.
capability.
The programmable unit can be used for open or closed loop applications with its
variable speed pressure/suction (duplex) pump.
4
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 5

PolyScience Controllers
Advanced Digital, Standard Digital, and Basic

Advanced Digital Controller


The PolyScience Advanced Digital Controller provides outstanding PolyScience
performance for demanding applications where programmability, Controllers
software bundle, or remote probe are not required.
Readout accuracy is ±0.25°C, stability is ±0.01°C, and temp-
erature control is up to 200°C. The LCD provides convenient
menu selection and displays set point and actual fluid temp-
ertures simultaneously.
• Full Graphic Display with
Multi-Language Help Menus The powerful microprocessor controller can be tuned to optimize
• 200°C Temperature Control PID performance for various fluids and volumes. In addition to
9106, 912
user-settable high and low safety limits, redundant 120V
over-temper-
Models
• RS232 Interface
ature and low-liquid level cutoffs are standard.
• Microprocessor Control
Equipped with a variable speed pressure/suction (duplex)
• Readout in °C and °F
pump, the Advanced Digital Controller may be used for either
open or closed loop applications.

Standard Digital Controller


1/4

Digital set and read to 0.1°C and microprocessor


1/2 control at a
price near analog technology distinguish 3/4 the PolyScience
Standard Digital Controller. Its stability 1/8
of ±0.05°C plus
temperature control up to 150°C are excellent1 for many applications.
/32
• Three User-defined Operation is simple: One Select/Set knob and three temperature
Temperature Preset Buttons preset buttons. The bright LED displays fluid temperature
• 150°C Temperature Control continuously, and with a quick touch of the Select/Set knob,
displays your set temperature. Choosing °C or °F temperature
• Easy-to-Read LED Display units, entering calibration values, and setting high limit temper-
• Accurate Microprocessor ature are quick and easy.
Control
All Standard Digital Controllers have a 2-speed pressure (sim-
• Excellent Performance -
plex) pump suitable for closed loop applications. Low pump
Moderate Price
speed is quiet and provides longer motor life, high speed is
preferable for more difficult pumping requirements.
A redundant safety backup for over-temperature and low-liquid
situations protects your work and equipment.

Basic Controller www.polyscience.com


The PolyScience Basic Controller is used on selected models.
Toll Free: 800-229-7569
It provides economical and accurate control with ±0.2°C stability USA and Canada
• Proportional Temperature and temperature control up to 100°C.
Worldwide: 847-647-0611
Control
Special controller design eliminates annoying radio frequency Fax: 847-647-1155
• 100°C Temperature Control electrical interference which can disrupt nearby lab equipment.
e-mail:
• Great for Routine Use
The 2-speed pressure (simplex) pump produces a flow of 9 or sales@polyscience.com
• Redundant Safety Backup 15 liters per minute on most models. Temperature readout is
®
• Most Economical Model via a supplied thermometer (non-mercury).
5
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 6

PolyScience

Refrigerating/Heating Circulators
The 9100 Series

Model 912 Model 9112 Model 9102 Model 9106


9100 Series
Features

• Most Popular Design


• Small Footprint -
Less Than 1 sq.ft.
• 6 Liter Reservoir
• Choice Of Four
Controllers
• Enhanced Cooling
Capacity
• Quiet Operation
• Easy-Access
Reuseable Filter

This series features a 6 liter


reservoir in a space-saving
vertical design. Only 8 1/4 in.
(21cm) wide, the small foot-
print conserves precious
bench space.
Programmable Model 9112. This top-of-the-line model features a wide temperature range
Size, performance, and a
and time/temperature programmability. Programs can be set directly from the front panel with
choice of four controllers
the aid of the Select/Set knob and multi-language display or from a PC using the RS232 inter-
combine to make this series
face. LabViewTM drivers and Excel® macros offer even greater programming and data logging
PolyScience's most popular
convenience. Remote probe capability plus variable speed pressure/ suction (duplex) pump
circulators.
further enhance the 9112’s capabilities.
Dependable, precise, and Advanced Digital Model 9102. The Advanced Digital Controller offers the same advanced per-
compact, all models feature formance as the Programmable model and is the ideal choice when remote probe,
redundant over-temperature time/temperature programming, or communication software are not required. The LCD display also
and low-liquid level protection. incorporates multi-language help menus that aid set-up and operation when using the Select/Set
knob. A built-in RS232 interface is standard. The variable speed pressure/suction pump can be used
The refrigeration system is
in both open and closed loop applications. Great performance for those on a budget.
designed to be used below
70°C. This allows rapid bath Standard Digital Model 9106. With the same cooling capacity as our more full featured mod-
cooling from 70°C or lower, els, this model combines high performance with economy. It is equipped with three user-defined
while maximizing temperature temperature preset buttons for rapid set point changes. The bright LED display provides read and
control and reducing energy set capability, and its ±0.05°C stability meets all but the most demanding requirements.
consumption above 70°C. Frequently used for cooling electrophoresis cells, viscometers, and general lab applications.
The hermetically-sealed com-
pressor is designed for years of Basic Model 912. Ideal for routine applications where extreme accuracy and stability are not
maintenance-free use. critical. An excellent, low-price alternative to tap water cooling for rotary evaporators and
condensers. Convenient set-point dial with supplied thermometer (alcohol) readout.

See pages 4 and 5 for additional controller information.


6
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 7

Upright, Space-Saving Design


6 Liter

Cooling Heating

40˚C 100˚ C
9100 Series
9112, 9102
30˚C
90˚ C
240V Models Applications
80˚ C

20˚C 70˚ C
Calibration
60˚ C
10˚C
50˚ C
9106, 912 Chromatography
240V Models
0 ˚C
40˚ C
Columns
-10˚C 30˚ C 120V Densitometers
Models
20˚ C
-20˚C Distillation
10˚ C
Condensers
-30˚C 0˚ C
0 15 30 45 60 75 90 105 0 5 10 15 20 25 30 35 40
Electrophoresis
Time In Minutes
Apparatus
General Laboratory
Cooling
9100 Series Specifications Isoelectric Focusing
Reservoir Capacity 6 liters Fluids For Below Ambient Work
Polarimeters
+20°C 200 Watts ✔ Select one that satisfies operating conditions,
Cooling Capacity @ 0°C 140 Watts including safety, flash point, and freezing point. Refractometers
-10°C 100 Watts ✔ Pick the lowest possible viscosity.
Rotary Evaporators
Over-Temperature Cutoff Adjustable ✔ Avoid synthetic fluids that are hygroscopic to
Low-Liquid Cutoff Yes prevent ice from forming in the reservoir. Spectrophotometers
Working Access 5 1/4 x 5 1/4 x 5 1/2 in. ✔ Minimize use of mixtures that may change con- Viscometers
lxwxd 13.3 x 13.3 x 14 cm centration due to evaporation.
Supplied with reservoir cover,
Overall Dimensions 15 3/4 x 8 1/4 x 22 1/2 in. ✔ Some mixtures may change from non-flamma- bypass tube, and male inlet/
lxwxh 40 x 21 x 57.1 cm ble to flammable if a volatile component is outlet tubing adapters for 3/8,
1/4
randomly added to keep the freezing point 1/4, and 3/16 inch (.95, .63,
Pump Inlet and Outlet in. FPT Rear Discharge depressed. and .47 cm) tubing. Also
Note: For Cooling Capacity (Watts x 3.41) = BTU/hr. includes 6-ft. (1.83 meter)
standard grounded electrical
cord with U.S. (120V) or
Specifications Model 9112 Model 9102 Model 9106 Model 912 European (240V) plug. Other
country-specific plugs avail-
Temperature Range –20° to 200°C –20° to 200°C –20° to 150°C –20° to 100°C
able; consult PolyScience.
Temperature Stability ± 0.01°C ± 0.01°C ± 0.05°C ± 0.2°C Programmable Model
Controller / RS232 Programmable / Yes Advanced Digital / Yes Standard Digital/ No Basic / No Accessories:
-Remote Probe
Readout Graphic LCD Graphic LCD LED Thermometer (supplied)
(10, 25, or 50-ft.)
Temperature Readout °C or °F °C or °F °C or °F N/A -Digital to Analog Adapter
Readout Accuracy ± 0.25°C ± 0.25°C ± 0.5°C N/A Accessories on pages 30
30 lpm max. (60 Hz) 30 lpm max. (60 Hz) and 31.
Pressure Flow Rate 2-speed, 9 or 15 lpm 2-speed, 9 or 15 lpm
22 lpm max. (50 HZ) 22 lpm max. (50 Hz) www.polyscience.com
22 lpm max. (60 Hz) 22 lpm max. (60 Hz)
Suction Flow Rate
15 lpm max. (50 Hz) 15 lpm max. (50 Hz)
N/A N/A Toll Free: 800-229-7569
USA and Canada
60Hz 1100 Watts 1100 Watts 1100 Watts 1100 Watts
Heater Worldwide: 847-647-0611
50Hz 2200 Watts 2200 Watts 1600 Watts 1600 Watts
Shipping Weight 69 lbs / 31.3 kg 69 lbs / 31.3 kg 66 lbs / 29.9 kg 65 lbs / 29.5 kg Fax: 847-647-1155
Cat. No. 120V, 60Hz, 12A 9112A11B 9102A11B 9106A11B 91A0A11B e-mail:
Cat. No. 240V, 50Hz, 9.9A 9112A12E 9102A12E 9106A12E 91A0A12E
sales@polyscience.com
®
Note: Performance specifications determined at ambient temperature of 20°C/68°F. For 50Hz units, derate cooling capacity by 17%.
7
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 8

PolyScience

Refrigerated/Heating Circulators
The 9000 Series

Model 9006 Model 9012 Model 9002


9000 Series
Features

• Low Profile Permits


Convenient Shelf or
Bench Top Placement
• Bath Top Work Space
• 6 Liter Reservoir
• Easy Access
Sample Immersion
• Ideal for Use On Mobile
Carts
• Easy-Access Reusable
Filter

PolyScience 9000 Series


Circulators combine excep-
tional performance with a low
profile design that permits
placement on shelves, bench
tops, even mobile carts with-
out sacrificing capabilities or
convenience. Each 9000
model features the same tem- Programmable Model 9012. This model features a -20°C to 200°C temperature range
perature range, cooling capac- and time/temperature programmability. The full graphic display with multi-language
ity, and pump as its 9100 help menus and Select/Set knob make operation and set-up quick and simple. Data
Series' counterpart while also logging via the RS232 interface and included software are also possible. LabViewTM
providing almost a full square drivers and Excel® macros provide even greater programming and data logging
foot of additional work space convenience. Remote probe capability and variable speed pressure/suction (duplex)
on its stainless steel top. pump are standard.

In applications where bench Advanced Digital Model 9002. Excellent temperature range and stability, combined
space is at a premium, 9000 with the easy-reading, full graphic display and multi-language help menus, make this
Series Circulators can be model suitable for many applications and budgets. The built-in RS232 port comes
placed on a shelf above the standard. The pump is a variable speed pressure/suction (duplex) type for open or
work area while still providing closed loop applications.
convenient eye-level access to Standard Digital Model 9006. Designed for routine use up to 150°C, this model
the controls. And their wide economically delivers the same cooling as our Programmable and Advanced Digital
footprint adds stability for cal- models. The convenient read-and-set LED display plus stability of ±0.05°C meets
ibration work or applications most requirements. Three user-defined temperature buttons offer quick set point
where cart-mounted use is changes for frequently used appications. The pump is 2-speed pressure (simplex) type
desirable. for closed loop applications.

See pages 4 and 5 for additional controller information.


8
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 9

Low Profile Design


6 Liter

Cooling Heating

40˚C 00˚ C 9000 Series


30˚C
90˚ C 9012, 9002
240V Models
Applications
80˚ C

20˚C 70˚ C
Calibration
60˚ C
10˚C
50˚ C 9006
Chromatography
0 ˚C
40˚ C
240V Models Columns
-10˚C
30˚ C Densitometers
20˚ C 120V
-20˚C Models Distillation
10˚ C
Condensers
-30˚C 0˚ C
0 15 30 45 60 75 90 105 0 5 10 15 20 25 30 35 40
Electrophoresis
Time In Minutes
Apparatus
General Laboratory
Cooling
9000 Series Specifications
Isoelectric Focusing
Reservoir Capacity 6 liters
Polarimeters
+20°C 200 Watts ✔ For optimum performance locate your
Cooling Capacity @ 0°C 140 Watts circulator on a level surface free from Refractometers
-10°C 100 Watts
drafts and direct sunlight. Rotary Evaporators
Over-Temperature Cutoff Adjustable
✔ Avoid locations where corrosive fumes,
Low-Liquid Cutoff Yes excessive moisture, or excessive dust are Spectrophotometers
present.
Working Access 5 1/4
x 5 1/4
x 5 1/2 in. Viscometers
lxwxd 13.3 x 13.3 x 14 cm ✔ Protect against voltage drops by using
properly grounded power outlets wired Supplied with reservoir cover,
Overall Dimensions 15 3/4 x 18 3/4 x 17 in. bypass tube, and male inlet/
lxwxh 40 x 47.6 x 43.2 cm with 14 gauge or larger diameter wire.
Locate the circulator close to the outlet tubing adapters for 3/8,
Pump Inlet and Outlet 1/4 in. FPT Rear Discharge power outlet. 1/4, and 3/16 inch (.95, .63,
and .47 cm) tubing. Also
Note: For Cooling Capacity (Watts x 3.41) = BTU/hr. includes 6-ft. (1.83 meter)
standard grounded electrical
cord with U.S. (120V) or
Specifications Model 9012 Model 9002 Model 9006 European (240V) plug. Other
Temperature Range -20° to 200°C -20° to 200°C -20° to 150°C country-specific plugs avail-
able; consult PolyScience.
Temperature Stability ±.01°C ±.01°C ±.05°C
Programmable Model
Controller / RS232 Programmable / Yes Advanced Digital / Yes Standard Digital / No Accessories:
Readout Graphic LCD Graphic LCD LED -Remote Probe
(10, 25, or 50-ft.)
Temperature Readout °C or °F °C or °F °C or °F
-Digital to Analog Adapter
Readout Accuracy ± 0.25°C ± 0.25°C ± 0.5°C
Accessories on pages 30
30 lpm max. (60 Hz) 30 lpm max. (60 Hz) and 31.
Pressure Flow Rate 2-speed, 9 or 15 lpm
22 lpm max. (50 Hz) 22 lpm max. (50 Hz)
22 lpm max. (60 Hz) 22 lpm max. (60 Hz)
www.polyscience.com
Suction Flow Rate N/A
15 lpm max. (50 Hz) 15 lpm max. (50 Hz) Toll Free: 800-229-7569
60Hz 1100 Watts 1100 Watts 1100 Watts USA and Canada
Heater
50Hz 2200 Watts 2200 Watts 1600 Watts
Worldwide: 847-647-0611
Shipping Weight 74 lbs / 34 kg 70 lbs / 32 kg 67 lbs / 30.4 kg
Fax: 847-647-1155
Cat. No. 120V, 60Hz, 12A 9012A11B 9002A11B 9006A11B
e-mail:
Cat. No. 240V, 50Hz, 9.9A 9012A12E 9002A12E 9006A12E
sales@polyscience.com
Note: Performance specifications determined at ambient temperature of 20°C/68°F. For 50Hz units, derate cooling capacity by 17%.
®
9
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 10

PolyScience

Refrigerating/Heating Circulators
The 9500 Series

Model 9502 Model 9512 Model 9506


9500 Series
Features

• -30°C Cooling Capability


• 13 Liter Reservoir
• Energy-Saving Cool
Command™ Refrigeration
System
• Large Reservoir,
Large Opening
• Easy-Access Reusable
Filter

PolyScience 9500 Series


Circulators offer exceptional
cooling capability over a
broad temperature range plus
a high-capacity, easy-to-
access 13 liter reservoir.
These versatile circulators also
feature our exclusive Cool
Command refrigeration system
and fuzzy logic energy man-
agement technique to deliver
up to 50% greater energy effi-
ciency than traditional sys- Programmable Model 9512. The Programmable Controller offers a wide temperature
tems. This advanced technolo- range, exceptional stability, and variable speed pressure/suction (duplex) pump along with
gy carefully monitors heat time/temperature programming and remote probe capability. RS232 interface and PC
load to deliver only the programming software are standard. LabView drivers and Excel® macros provide even
TM

amount of refrigerant needed. greater programming and data logging convenience. The full graphic LCD display and
As a result, it permits fast bath multi-language help menus simplify operation and set-up.
cooling even at high tempera-
tures without excessive energy Advanced Digital Model 9502. Excellent temperature range and stability combined with
consumption. an easy-reading graphic display make this model a fine choice for many applications. The
pump is a powerful variable speed pressure/suction (duplex) type for open or closed loop
To further add to their applica- applications. A built-in RS232 interface comes standard. The full graphic LCD display
tion versatility, Models 9512 and multi-language help menus simplify operation and set-up.
and 9502 feature a powerful
variable speed pressure/suction Standard Digital Model 9506. The same -30°C cooling capacity of our Programmable and
(duplex) pump, making them Advanced Digital models at a price comparable to units with analog controllers make the
ideal for use where continuous, Model 9506 a great value for applications where high heat removal at close to ambient
low-temperature operation is temperature is required. Microprocessor-based controller provides set-and-read functionality;
required or where the viscosity three user-defined temperature buttons make set point changes quick and easy. The 2-speed
of the liquid may affect pressure (simplex) pump is suitable for closed loop applications.
circulation uniformity.
See pages 4 and 5 for additional controller information.
10
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 11

Low Temperature Control


13 Liter

Cooling Heating
100˚ C 9500 Series
40 C
˚ 9512, 9502
90˚ C
240V Models Applications
30 C
˚ 80˚ C

70˚ C
20 C
˚
60˚ C
Low Temperature
10 C 9506
˚ 50˚ C
Calibration
240V Models
0 C 40˚ C
˚ Cloud Point and Pour
30˚ C
-10 C
˚ Point Testing
20˚ C 120V
-20 C
˚ 10˚ C Models Cell Freezing
-30 C
0˚ C
0 10 20 30 40 50 60 70 80 Low Temperature
˚ 0 25 50 75 100 125 150 175
Time In Minutes Reactions
Distillation Condensers
9500 Series Specifications General Laboratory
Reservoir Capacity 13 liters Cooling
+20°C 660 Watts For Best Temperature Control Rotary Evaporators
0°C 480 Watts
Cooling Capacity @
-20°C 240 Watts ✔Use the largest diameter tubing possible Spectrophotometers
-30°C 100 Watts for maximum flow.
Viscosity Studies
Over-Temperature Cutoff Adjustable ✔Insulate the tubing between the circulator
Low-Liquid Cutoff Yes and the application.
✔Choose a fluid with lowest viscosity at the Supplied with reservoir cover,
Reservoir Drain Yes
bypass tube, and male inlet/
Working Access 6 x 11 x 5 1/2 in. selected operating temperature. outlet tubing adapters for 3/8,
lxwxd 14 x 28 x 15.2 cm ✔Select pump speed for optimum fluid mix- 1/4, and 3/16 inch (.95, .63,
ing. This helps assure good uniformity. and .47 cm) tubing. Also
Overall Dimensions 17 x 15 1/2 x 24 3/4 in.
includes 6-ft. (1.83 meter)
lxwxh 43 x 39.4 x 62.9 cm
✔Keep reservoir covered. standard grounded electrical
Pump Inlet and Outlet 1/4 in. FPT Rear Discharge cord with U.S. (120V) or
✔Consider the use of a remote probe. European (240V) plug. Other
Note: For Cooling Capacity (Watts x 3.41) = BTU/hr. country-specific plugs avail-
able; consult PolyScience.
Specifications Model 9512 Model 9502 Model 9506 Programmable Model
Temperature Range -30° to 200°C -30° to 200°C -30° to 150°C Accessories:
Temperature Stability ± 0.01°C ± 0.01°C ± 0.05°C
-Remote Probe
(10, 25, or 50-ft.)
Controller / RS232 Programmable / Yes Advanced Digital / Yes Standard Digital / No -Digital to Analog Adapter
Readout Graphic LCD Graphic LCD LED Accessories on pages 30
Temperature Readout °C or °F °C or °F °C or °F and 31.
Readout Accuracy ± 0.25°C ± 0.25°C ± 0.5°C
30 lpm max. (60 Hz) 30 lpm max. (60 Hz) www.polyscience.com
Pressure Flow Rate 2-speed, 9 or 15 lpm
22 lpm max. (50 Hz) 22 lpm max. (50 Hz)
Toll Free: 800-229-7569
22 lpm max. (60 Hz) 22 lpm max. (60 Hz)
Suction Flow Rate
15 lpm max. (50 Hz) 15 lpm max. (50 Hz)
N/A USA and Canada
60Hz 1100 Watts 1100 Watts 1100 Watts Worldwide: 847-647-0611
Heater
50Hz 2200 Watts 2200 Watts 1600 Watts Fax: 847-647-1155
Shipping Weight 136 lbs / 61.7 kg 134 lbs / 60.8 kg 130 lbs / 59.0 kg
e-mail:
Cat. No. 120V, 60Hz, 13A 9512A11C 9502A11C 9506A11C sales@polyscience.com
Cat. No. 240V, 50Hz, 9.8A 9512A12E 9502A12E 9506A12E
®
Note: Performance specifications determined at ambient temperature of 20°C/68°F. For 50Hz units, derate cooling capacity by 17%.
11
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 12

PolyScience

Refrigerating/Heating Circulators
The 9700 Series

Model 9702 Model 9712 Model 9706


9700 Series
Features

• -40°C Cooling
Capability
• 13 Liter Reservoir
• Broad Operating
Temperature Range
• Ample Reservoir for
Sample Immersion
• Cool Command™
Refrigeration System
• Enlarged Access Opening
• Easy-Access Reuseable
Filter

Ultra-low cooling capability,


large 13 liter reservoir, and
integral over-temperature and
low-liquid level protection
combine to make PolyScience
9700 Series Circulators ideal
for a wide range of demanding
applications.
Programmable Model 9712. This model offers the widest temperature range along with
Models 9712 and 9702 offer a high stability and variable speed pressure/suction (duplex) pump. Additional features
-40° to 200°C temperature include time/temperature programming and remote probe capability. RS232 interface
range with ±0.01°C tempera- and software for PC programming are standard. LabView drivers and Excel® macros
TM

ture stability. The Model 9706 offer even greater programming and data logging convenience. The full graphic LCD
features a temperature range of display with multi-language help menus aid in operation and set-up.
-40° to 150°C with ±0.05°C
Advanced Digital Model 9702. Excellent temperature range and stability combined with
stability. All models feature our
easy-reading graphic display make this model a fine choice for many applications and
Cool Command refrigeration
budgets. A built-in RS232 interface comes standard. The pump is a powerful variable
system and fuzzy logic energy
speed pressure/suction (duplex) type for open or closed loop applications. The full graphic
management technique to
LCD display with multi-language help menus simplify operation and set-up.
deliver up to 50% greater energy
efficiency than traditional sys- Standard Digital Model 9706. A -40°C cooling capacity and +150°C upper temperature
tems. This advanced technolo- limit make this circulator an economical choice for applications where high heat removal
gy carefully monitors heat load at close to ambient temperatures is required. Microprocessor-based controller provides
to deliver only the amount of set-and-read functionality; three user-defined temperature buttons make set point
refrigerant needed. As a result, changes quick and simple. The 2-speed pressure (simplex) pump is suitable for closed
it permits fast bath cooling loop applications.
even at high temperatures
without excessive energy con-
sumption.
See pages 4 and 5 for additional controller information.
12
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 13

Extra Low Temperature Control


13 Liter

Cooling Heating

30˚ C 100˚ C 9700 Series


20˚ C 90˚ C 9712, 9702
240V Models
Applications
80˚ C
10˚ C
70˚ C
0˚ C
60˚ C Low Temperature
9706
-10˚ C 50˚ C
240V Models
Calibration
40˚ C
-20˚ C
Cloud Point and Pour
30˚ C
-30˚ C Point Testing
20˚ C 120V
-40˚ C
10˚ C
Models Cell Freezing
-50˚ C
0 20 40 60 80 100 120 140
0˚ C
0 10 20 30 40 50 60 70 80
Low Temperature
Time In Minutes Reactions
Distillation Condensers
General Laboratory
9700 Series Specifications
Cooling
Reservoir Capacity 13 liters
Fluids For Below Ambient Work Rotary Evaporators
+20°C 680 Watts
Cooling Capacity @ 0°C 450 Watts ✔Select one that satisfies operating conditions, Spectrophotometers
-30°C 160 Watts including safety, flash point and freezing point.
Viscosity Studies
Over-Temperature Cutoff Adjustable
✔Pick the lowest possible viscosity.
Low-Liquid Cutoff Yes Supplied with reservoir cover,
✔Avoid synthetic fluids that are hygroscopic to bypass tube, and male inlet/
Reservoir Drain Yes prevent ice from forming in the reservoir. outlet tubing adapters for 3/8,
Working Access 6 x 11 x 5 1/2 in. 1/4, and 3/16 inch (.95, .63,
✔Minimize use of mixtures that may change
lxwxd 14 x 28 x 15.2 cm and .47 cm) tubing. Also
concentration due to evaporation. includes 6-ft. (1.83 meter)
Overall Dimensions 17 x 15 1/2 x 24 3/4 in.
lxwxh 43 x 39.4 x 62.9 cm ✔Some mixtures may change from non-flamma- standard grounded electrical
ble to flammable if a volatile component is cord with U.S. (120V) or
Pump Inlet and Outlet 1/4 in. FPT Rear Discharge European (240V) plug. Other
randomly added to keep the freezing point country-specific plugs avail-
Note: For Cooling Capacity (Watts x 3.41) = BTU/hr. depressed. able; consult PolyScience.
Programmable Model
Specifications Model 9712 Model 9702 Model 9706
Accessories:
Temperature Range -40° to 200°C -40° to 200°C -40° to 150°C -Remote Probe
Temperature Stability ± 0.01°C ± 0.01°C ± 0.05°C (10, 25, or 50-ft.)
-Digital to Analog Adapter
Controller / RS232 Programmable / Yes Advanced Digital / Yes Standard Digital / No
Thermometry Calibration
Readout Graphic LCD Graphic LCD LED
Reservoir and other
Temperature Readout °C or °F °C or °F °C or °F Accessories on pages 30
Readout Accuracy ± 0.25°C ± 0.25°C ± 0.5°C and 31.
30 lpm max. (60 Hz) 30 lpm max. (60 Hz)
Pressure Flow Rate 2-speed, 9 or 15 lpm
22 lpm max. (50 Hz) 22 lpm max. (50 Hz) www.polyscience.com
22 lpm max. (60 Hz) 22 lpm max. (60 Hz) Toll Free: 800-229-7569
Suction Flow Rate N/A
15 lpm max. (50 Hz) 15 lpm max. (50 Hz) USA and Canada
60Hz 1100 Watts 1100 Watts 1100 Watts
Heater
50Hz 2200 Watts 2200 Watts 1600 Watts
Worldwide: 847-647-0611
Shipping Weight 140 lbs / 63.5 kg 138 lbs / 62.6 kg 138 lbs / 62.6 kg Fax: 847-647-1155
Cat. No. 120V, 60Hz, 14A 9712A11C 9702A11C 9706A11C e-mail:
Cat. No. 240V, 50Hz, 9.9A 9712A12E 9702A12E 9706A12E
sales@polyscience.com
®
Note: Performance specifications determined at ambient temperature of 20°C/68°F. For 50Hz units, derate cooling capacity by 17%.
13
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 14

PolyScience

Refrigerating/Heating Circulators
The 9600 Series

Model 9602 Model 9612 Model 9606


9600 Series
Features

• -25°C Cooling Capability


• 28 Liter Reservoir
Accommodates Large or
Multiple Samples
• Extra Large Reservoir
Opening
• Energy-Saving Cool
Command™
Refrigeration System
• Bath Top Work Space
• Easy-Access Resuable
Filter

The 9600 Series combines


-25°C cooling capacity with a
spacious 28 liter reservoir to
provide precise temperature
control for large or multiple
samples even under rapidly
changing heat loads. Plus they
feature large 101⁄4 by 101⁄4 in.
Programmable Model 9612. The most versatile model in the 9600 Series, the 9612
reservoir openings to make
provides precise temperature control from -25°C to +150°C and features time/temperature
immersion and retrieval of
programming, remote probe capability, and a variable speed pressure/suction (duplex)
samples quick and easy.
pump. An RS232 interface and PC programming software are standard while LabView TM

All 9600 Series models also drivers and Excel® macros provide even greater programming and data logging conven-
feature our Cool Command ience. A full graphic LCD display with multi-language help menus simplify operation and
refrigeration system and fuzzy set-up.
logic energy management tech-
Advanced Digital Model 9602. A fine choice for more modest applications and budgets,
nique to deliver up to 50%
the 9602 features -25°C to +150°C temperature control, a powerful variable speed pres-
greater energy efficiency than
sure/suction (duplex) pump for open or closed loop applications, and integral RS232
traditional systems. This
interface. A full graphic LCD display with multi-language help menus simplify operation
advanced technology carefully
and set-up.
monitors heat load to deliver
only the amount of refrigerant Standard Digital Model 9606. The most economical model in this series, the 9606 offers
needed. As a result, it permits the same temperature range and cooling capacity as our more full-featured models. A
fast bath cooling even at high microprocessor-based controller provides set-and-read functionality; three user-defined
temperatures without excessive temperature buttons make set point changes quick and simple. The 2-speed pressure
energy consumption. (simplex) pump is suitable for closed loop applications.

See pages 4 and 5 for additional controller information.


14
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 15

Large Access Reservoir


28 Liter

Cooling Heating

30˚ C 100˚ C 9600 Series


20˚ C 90˚ C 9612, 9602
240V Models
Applications
80˚ C
10˚ C
70˚ C
0˚ C
60˚ C
Temperature Calibration
-10˚ C 50˚ C 9606
40˚ C
240V Models Cloud Point and Pour
-20˚ C
Point Testing
30˚ C
-30˚ C
20˚ C Low Temperature
120V
-40˚ C 10˚ C Models Reactions
-50˚ C
0 20 40 60 80 100 120 140
0˚ C
0 25 50 75 100 125 150 175 200 Distillation Condensers
Time In Minutes
General Laboratory
Cooling
Rotary Evaporators
9600 Series Specifications
Spectrophotometers
Reservoir Capacity 28.4 liters
Selectable Pump Speed Advantages: Sample Tempering
+20°C 700 Watts
Cooling Capacity @ 0°C 510 Watts
Slow Speed ✔ Quieter Operation Viscosity Studies
-20°C 260 Watts
Over-Temperature Cutoff Adjustable
✔ Longer Motor Life
Low-Liquid Cutoff Yes ✔ Minimizes Bath Turbulence
Reservoir Drain Yes ✔ Reduce friction heating of bath Supplied with reservoir cover,
bypass tube, and male inlet/
Working Access 10 1/4 x 10 1/4 x 10 1/4 in. Faster Speed ✔ Responds Quickly to Changes outlet tubing adapters for 3/8,
lxwxd 26 x 26 x 26 cm 1/4, and 3/16 inch (.95, .63,
✔ Pumps to Multiple Systems and .47 cm) tubing. Also
Overall Dimensions 19 1/2 x 27 1/2 x 18 1/2 in.
lxwxh 49.5 x 70 x 47 cm ✔ Better Flow in Small Tubing includes 6-ft. (1.83 meter)
standard grounded electrical
Pump Inlet and Outlet 1/4 in. FPT Rear Discharge ✔ Better Uniformity with Viscous Fluids cord with U.S. (120V) or
Note: Cooling capacity, Watts x 3.41 = BTU’s/hr.
European (240V) plug. Other
country-specific plugs avail-
able; consult PolyScience.
Specifications Model 9612 Model 9602 Model 9606
Programmable Model
Temperature Range -25° to 150°C -25° to 150°C -25° to 150°C Accessories:
Temperature Stability ± 0.01°C ± 0.01°C ± 0.05°C -Remote Probe
(10, 25, or 50-ft.)
Controller / RS232 Programmable / Yes Advanced Digital / Yes Standard Digital / No
-Digital to Analog Adapter
Readout Graphic LCD Graphic LCD LED
Accessories on pages 30
Temperature Readout °C or °F °C or °F °C or °F and 31.
Readout Accuracy ± 0.25°C ± 0.25°C ± 0.5°C

Pressure Flow Rate


30 lpm max. (60 Hz) 30 lpm max. (60 Hz)
2-speed, 9 or 15 lpm
www.polyscience.com
22 lpm max. (50 Hz) 22 lpm max. (50 Hz)
Toll Free: 800-229-7569
22 lpm max. (60 Hz) 22 lpm max. (60 Hz)
Suction Flow Rate
15 lpm max. (50 Hz) 15 lpm max. (50 Hz)
N/A USA and Canada
60Hz 1100 Watts 1100 Watts 1100 Watts Worldwide: 847-647-0611
Heater
50Hz 2200 Watts 2200 Watts 1600 Watts
Fax: 847-647-1155
Shipping Weight 153 lbs / 69.4 kg 150 lbs / 68.0 kg 148 lbs / 67.1 kg
e-mail:
Cat. No. 120V, 60Hz, 13A 9612A11C 9602A11C 9606A11C sales@polyscience.com
Cat. No. 240V, 50Hz, 9.8A 9612A12E 9602A12E 9606A12E
®
Note: Performance specifications determined at ambient temperature of 20°C/68°F. For 50Hz units, derate cooling capacity by 17%.
15
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 16

PolyScience

Heating Circulators
The 8000 Series

Model 812 Model 8006 Model 8012 Model 8002


8000 Series
Features

• Above Ambient
Temperature Control
• 6 Liter
• Small Footprint,
Low Profile
• Choice of
Microprocessor or
Analog Controller

Compact and powerful,


PolyScience 8000 Series
Circulators are ideal for pre-
cise control of temperature
from 5°C above ambient to as
high as 200°C. Four different
controllers are available – from
a full-featured, fully program-
mable controller to a low-cost, Programmable Model 8012. The most versatile model in the 8000 Series, the 8012 provides
set-it-and-forget-it analog precise temperature control from 5°C above ambient to 200°C and features time/temperature
model. programming, remote probe capability, and a variable speed pressure/suction (duplex) pump.
An RS232 interface and PC programming software are standard while LabView drivers and
TM

For even greater operational Excel® macros provide even greater programming and data logging convenience. A full
flexibility, a variety of acces- graphic LCD display and multi-language help menus simplify operation and set-up.
sories and add-ons are also
available for 8000 Series Advanced Digital Model 8002. A fine choice for more modest applications and budgets, the
Circulators. Our tap water 8002 features the same temperature range and stability as the 8012 as well as a full graphic
cooling coil (Cat. No. 060300; LCD display with multi-language help menus. Other standard features include a powerful
page 30) allows operation at variable speed pressure/suction (duplex) pump for open or closed loop applications and integral
temperatures closer to ambient RS232 interface.
and provides more rapid cool- Standard Digital Model 8006. The most economical microprocessor-controlled model in
down from elevated tempera- this series, the 8006 has an upper temperature limit of 150°C and a bright set-and-read LED
tures. And for below ambient display. Three user-defined temperature buttons make set point changes quick and simple.
work, our KR60 Flow-Through The 2-speed pressure (simplex) pump is suitable for closed loop applications.
Cooler (page 28) can be
added to provide cooling Basic Model 812. The lowest priced Heating Circulator in the 8000 Series, the 812 is ideal
down to -25°C. for use in applications where set point changes are infrequent. Temperature is set via a rotary
dial and is read on a supplied alcohol thermometer. The 2-speed pressure (simplex) pump is
suitable for closed loop applications.

See pages 4 and 5 for additional controller information.


16
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 17

Compact and Powerful Control


6 Liter

Heating

100˚ C 8000 Series


8012, 8002
90˚ C
240V Models Applications
80˚ C

70˚ C High Temperature Precautions:


60˚ C Before starting your circulator, set both a Aging Studies
50˚ C
8006, 812 Safety Set point temperature as well as your
240V Models Calibration
40˚ C operating set point temperature.
30˚ C The Safety Set feature prevents your unit from Densitometers
120V excessive heat by switching off power to the
20˚ C
Models Extractor - Concentrators
10˚ C heater in case of low-liquid level or primary
0˚ C controller failure. This feature has a DNA Melting Curves
0 5 10 15 20 25 30 35 40
temperature range of 40°C to 210°C. Enzyme Assays
Time In Minutes

Kinetic Research
Polymer Studies
Petroleum Testing
8000 Series Specifications
Temperature Gradients
Reservoir Capacity 6 liters
High Temperature Precautions: Spectrophotometers
Over-Temperature Cutoff Adjustable
✔ Select a fluid with a flash point well
Low-Liquid Cutoff Yes above the operating temperature. Viscosity Studies
Working Access 5 1/4 x 5 1/4 x 5 1/2 in. Supplied with reservoir cover,
✔ Silicone oils are preferred over mineral
lxwxd 13.3 x 13.3 x 14 cm bypass tube, and male inlet/
oil which may smoke or burn.
Overall Dimensions 14 1/4 x 8 1/4 x 14 in. outlet tubing adapters for 3/8,
lxwxh 37.5 x 21 x 35.6 cm ✔ Place circulator in a fume hood if 1/4, and 3/16 inch (.95, .63,
noxious vapors may be present. and .47 cm) tubing. Also
Pump Inlet and Outlet 1/4 in. FPT Rear Discharge includes 6-ft. (1.83 meter)
✔ Use high temperature tubing and tub- standard grounded electrical
ing adapters. See page 30 for acces- cord with U.S. (120V) or
sories. European (240V) plug. Other
country-specific plugs avail-
Specifications Model 8012 Model 8002 Model 8006 Model 812 able; consult PolyScience.
Temperature Range Ambient +5° to 200°C Ambient +5° to 200°C Ambient +5° to 150°C Ambient +5° to 100°C Programmable Model
Accessories:
Temperature Stability ±0.01°C ±0.01°C ±0.05°C ±0.2°C
-Remote Probe
Controller / RS232 Programmable / Yes Advanced Digital / Yes Standard Digital / No Basic / No (10, 25, or 50-ft.)
Readout Graphic LCD Graphic LCD LED Thermometer (supplied) -Digital to Analog Adapter
Readout Accuracy ±0.25°C ±0.25°C ±0.5°C N/A Accessories on pages 30
and 31.
Temperature Readout °C or °F °C or °F °C or °F N/A
30 lpm max. (60 Hz) 30 lpm max. (60 Hz)
Pressure Flow Rate 2-speed, 9 or 15 lpm 2-speed, 9 or 15 lpm
22 lpm max. (50 Hz) 22 lpm max. (50 Hz)
22 lpm max. (60 Hz) 22 lpm max. (60 Hz) www.polyscience.com
Suction Flow Rate N/A N/A
15 lpm max. (50 Hz) 15 lpm max. (50 Hz) Toll Free: 800-229-7569
Heater
60Hz 1100 Watts 1100 Watts 1100 Watts 1100 Watts USA and Canada
50Hz 2200 Watts 2200 Watts 1600 Watts 1600 Watts
Worldwide: 847-647-0611
Shipping Weight 25 lbs / 11.3 kg 25 lbs / 11.3 kg 22 lbs / 9.8 kg 22 lbs / 9.8 kg
Cat. No. 120V,
Fax: 847-647-1155
8012A11B 8002A11B 8006A11B 80A0A11B
50/60Hz, 11A e-mail:
Cat. No. 240V, sales@polyscience.com
8012A12E 8002A12E 8006A12E 80A0A12E
50/60Hz, 9.8A
®
Note: Performance specifications determined at ambient temperature of 20°C/68°F.
17
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:47 PM Page 18

PolyScience

Heating Circulators
The 8100 Series

Model 8112 Model 8102 Model 8106


8100 Series
Features

• Above Ambient
Temperature Control
• 13 Liter Reservoir
• Large Reservoir Opening
• Small Footprint, Low
Profile
• Carrying Handles For
Easy Placement

These medium capacity 8100


Series Heating Circulators are
ideal for maintaining larger or
multiple samples at tempera-
tures from 5°C above ambient
to 150°C.
They feature powerful, high-
wattage heaters to provide
excellent temperature stability
and respond quickly to
changes in heat demand.
Programmable Model 8112. Our best 8100 Series Circulator, the 8112 provides
precise temperature control from 5°C above ambient to 150°C and features time/
temperature programming, remote probe capability, and a variable speed pressure/suction
(duplex) pump. An RS232 interface and PC programming software are standard while
LabViewTM drivers and Excel® macros provide even greater programming and data
logging convenience. A full graphic LCD display with multi-language help menus
simplify operation and set-up.
Advanced Digital Model 8102. A bit less full-featured than our Programmable model, the
8102 offers identical temperature performance at a more modest price. Standard features
include a full graphic LCD display with multi-language help menus, powerful variable
pressure/suction (duplex) pump for open or closed loop applications, and integral RS232
interface.
Standard Digital Model 8106. The most economical microprocessor-controlled model
in this series, the 8106 also provides ambient +5°C to 150°C temperature control. It
features a bright set-and-read LED display, three user-defined temperature set point but-
tons, and a 2-speed pressure (simplex) pump suitable for closed loop applications.

See pages 4 and 5 for additional controller information.


18
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 19

Compact and Powerful Control


13 Liter

Heating

100˚ C
8112, 8102
8100 Series
90˚ C 240V Models Applications
80˚ C

70˚ C

60˚ C
Aging Studies
50˚ C
8106
240V Models
Calibration
40˚ C

30˚ C Densitometers
20˚ C 120V If you operate above 90°C, be aware of Extractor - Concentrators
Models
10˚ C the following:
DNA Melting Curves
0˚ C
0 10 20 30 40 50 60 70 80 ✔ Heat loss from vapor may cause poor
Time In Minutes temperature stability. Enzyme Assays
✔ Use a cover and floating hollow balls Kinetic Research
to help prevent heat and vapor loss.
Polymer Studies
✔ Fluid lost from vapor will have to be
frequently replenished. Petroleum Testing
✔ If fluid other than water is used, a Temperature Gradients
8100 Series Specifications
fume hood may be required to prevent Spectrophotometers
Reservoir Capacity 13 liters
the buildup of vapors inside the room.
Over-Temperature Cutoff Adjustable Viscosity Studies
Low-Liquid Cutoff Yes
Working Access 51/4 x 81/2 x 73/4 in. Supplied with reservoir cover,
lxwxd 13.3 x 21.6 x 19.7 cm bypass tube, and male inlet/
Overall Dimensions 15 1/2 x 10 7/8 x 14 3/4 in.
outlet tubing adapters for 3/8,
lxwxh 39.4 x 27.6 x 37.5 cm
1/4, and 3/16 inch (.95, .63,
and .47 cm) tubing. Also
Pump Inlet and Outlet 1/4 in. FPT Rear Discharge includes 6-ft. (1.83 meter)
standard grounded electrical
cord with U.S. (120V) or
European (240V) plug. Other
country-specific plugs avail-
able; consult PolyScience.
Specifications Models 8112 Models 8102 Models 8106
Programmable Model
Temperature Range Ambient +5° to 150°C Ambient +5° to 150°C Ambient +5° to 150°C Accessories:
Temperature Stability ±0.01°C ±0.01°C ±0.05°C -Remote Probe
Controller / RS232 Programmable / Yes Advanced Digital / Yes Standard Digital / No
(10, 25, or 50-ft.)
-Digital to Analog Adapter
Readout Graphic LCD Graphic LCD LED
Accessories on pages 30
Readout Accuracy ±0.25°C ±0.25°C ±0.5°C and 31.
Temperature Readout °C or °F °C or °F °C or °F
30 lpm max. (60 Hz) 30 lpm max. (60 Hz)
Pressure Flow Rate
22 lpm max. (50 Hz) 22 lpm max. (50 Hz)
2-speed, 9 or 15 lpm www.polyscience.com
22 lpm max. (60 Hz) 22 lpm max. (60 Hz) Toll Free: 800-229-7569
Suction Flow Rate N/A
15 lpm max. (50 Hz) 15 lpm max. (50 Hz) USA and Canada
60Hz 1100 Watts 1100 Watts 1100 Watts Worldwide: 847-647-0611
Heater
50Hz 2200 Watts 2200 Watts 1600 Watts
Fax: 847-647-1155
Shipping Weight 40 lbs / 18 kg 32 lbs / 14.5 kg 28 lbs / 12.7 kg
Cat. No. 120V, 50/60Hz, 11A 8112A11B 8102A11B 8106A11B
e-mail:
sales@polyscience.com
Cat. No. 240V, 50/60Hz, 9.8A 8112A12E 8102A12E 8106A12E
®
Note:Performance specifications determined at ambient temperature of 20°C/68°F.
19
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 20

PolyScience

Heating Only Circulators


The 8200 Series

Model 8202 Model 8212 Model 8206


8200 Series
Features

• Above Ambient
Temperature Control
• 28 Liter Reservoir
• Large Reservoir Opening
• Compact Design
• Carrying Handles
For Easy Placement

PolyScience 8200 Series


Heating Circulators feature
spacious 28 liter reservoirs
and ambient +5°C to 150°C
temperature control to keep
large or multiple samples at a
constant, stable temperature.
Their powerful, high-wattage
heaters respond quickly to
changes in heat demand and
provide excellent temperature
stability. Programmable Model 8212. Ambient +5°C to 150°C temperature control, ±0.01°C
temperature stability, time/temperature programming, and remote probe capability make
For operational convenience,
this PolyScience's best large-capacity Heating Circulator. Other features include
all 8200 Series feature a large
variable speed pressure/suction (duplex) pump, RS232 interface and PC programming
121/8 x 103/8 in. reservoir open-
software, LabView drivers and Excel® macros, and full graphic LCD display with multi-
TM
ing for easy access and carrying
language help menus.
handles for added portability.
Advanced Digital Model 8202. The same broad temperature control range and excellent
temperature stability performance of our top of the line model at a more modest price.
Standard features include a full graphic LCD display with multi-language help menus,
powerful variable speed pressure/suction (duplex) pump for open or closed loop applications,
and integral RS232 interface.
Standard Digital Model 8206. Ideal for those on a tight budget, the 8206 is our most
economical large-capacity Heating Circulator. As with our other 8200 Series Circulators,
it provides ambient +5°C to 150°C temperature control. Standard features include a
bright set-and-read LED display, three user-defined temperature set point buttons, and a
2-speed pressure (simplex) pump suitable for closed loop applications.

See pages 4 and 5 for additional controller information.


20
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 21

Compact and Powerful Control


28 Liter

Heating 8200 Series Specifications

100˚ C
Reservoir Capacity 28 liters 8200 Series
90˚ C
8212, 8202
240V Models
Over-Temperature Cutoff Adjustable Applications
80˚ C Low-Liquid Cutoff Yes
70˚ C Working Access 121/8 x 103/8 x 8 in. Calibration
60˚ C lxwxd 30.8 x 26.4 x 20.3 cm
50˚ C 8206 Overall Dimensions 22 3/4 x 13 3/16 x 14 3/4 in. Chromatography
40˚ C
240V Models lxwxh 55.8 x 33.5 x 37.5 cm Columns
Pump Inlet and Outlet 1/4 in. FPT Rear Discharge
30˚ C Densitometers
20˚ C
120V Distillation
10˚ C Models Condensers
0˚ C ®
0 25 50 75 100 125 150 175 200
Electrophoresis
Time In Minutes
Apparatus
Specifications Models 8212 Models 8202 Models 8206 General Laboratory
Temperature Range Ambient +5° to 150°C Ambient +5° to 150°C Ambient +5° to 150°C Isoelectric Focusing
Temperature Stability ±0.01°C ±0.01°C ±0.05°C
Polarimeters
Controller / RS232 Programmable / Yes Advanced Digital / Yes Standard Digital / No
Refractometers
Readout Graphic LCD Graphic LCD LED
Readout Accuracy ±0.25°C ±0.25°C ±0.5°C Rotary Evaporators
Temperature Readout °C or °F °C or °F °C or °F Spectrophotometers
30 lpm max. (60 Hz) 30 lpm max. (60 Hz) Viscometers
Pressure Flow Rate 2-speed, 9 or 15 lpm
22 lpm max. (50 Hz) 22 lpm max. (50 Hz)
22 lpm max. (60 Hz) 22 lpm max. (60 Hz)
Suction Flow Rate N/A
15 lpm max. (50 Hz) 15 lpm max. (50 Hz)
60Hz 1100 Watts 1100 Watts 1100 Watts
Heater
50Hz 2200 Watts 2200 Watts 1600 Watts
Shipping Weight 50 lbs / 23 kg 43 lbs / 19.5 kg 40 lbs / 18.1 kg
Cat. No. 120V, 50/60hz, 11A 8212A11B 8202A11B 8206A11B
Cat. No. 240V, 50/60Hz, 9.8A 8212A12E 8202A12E 8206A12E
Note: Performance specifications determined at ambient temperature of 20°C/68°F.

Supplied with reservoir cover, bypass tube, and male inlet/outlet tubing adapters for 3/8, 1/4, and 3/16 inch (.95,
.63, and .47 cm) tubing. Also includes 6-ft. (1.83 meter) standard grounded electrical cord with U.S. (120V) or
European (240V) plug. Other country-specific plugs available; consult PolyScience.

Programmable Model Accessories: www.polyscience.com


-Remote Probe (10, 25, or 50-ft.) Toll Free: 800-229-7569
-Digital to Analog Adapter USA and Canada
Accessories on pages 30 and 31. Worldwide: 847-647-0611
Fax: 847-647-1155
e-mail:
sales@polyscience.com

21
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 22

PolyScience

Circulating Water Bath


The Model 8306

Model 8306
Model 8306
Features

• Easy-to-Use
Microprocessor
Controller
• Three Preset
Temperatures Buttons
Permit Rapid
Temperature Set Point
Changes
• 28 Liters
• External Circulation
Capability
• Hinged, See-Through
Cover

The Model 8306 Circulating


Water Bath is an excellent
general purpose bath suitable
for a wide variety of laboratory
applications, including those
requiring external circulation.
It is supplied with a sample Model 8306. Designed specifically for coliform testing, the Model 8306
tray for the bath bottom. features the PolyScience Standard Digital Controller. It incorporates three preset
temperature buttons which can be used to rapidly change to common
coliform test temperatures, such as 44.5°C, 45.5°C, 41.5°C, and 35.0°C, or
other temperatures from ambient +5°C to 150°C.
Bath temperature is displayed on a bright LED readout. A quick press of a
knob displays set point and also selects temperature units (°C or °F).
Use distilled water for temperatures up to For operational convenience, the Model 8306 is equipped with a tilting,
90°C. Do not use deionized water. see-through polycarbonate cover which drains back into the bath when
For procedures at higher temperatures opened and an integral 2-speed (simplex) pump which can be used
(i.e., non-coliform testing), use the following to circulate the bath liquid to other instruments using a closed loop
guidelines when selecting a bath medium: configuration.
✔ Use only fluids that meet your safety,
All wetted components are corrosion-resistant 300 stainless steel. The outer
health, and equipment requirements.
case is protected with a durable, easy-to-clean epoxy powder coating.
✔ Use a fluid suitable for the temperature
range desired.
✔ Use a fluid compatible with 300 series
stainless steel.

See page 5 for additional information on the Standard Controller used on the Model 8306.
22
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 23

Ideal For Coliform Testing


28 Liter

Model 8306
The Model 8306
Applications
Model 8306

This circulating bath is specifically designed to be Reservoir Capacity 28 liters


used for the following Coliform tests: Temperature Range Ambient +5° to 150°C Standard Method
Temperature Stability ±0.05°C Coliform Testing
1. APHA, AWWA, WEF and EPA fecal coliform
Readout LED, °C or °F to 0.1°
determination at 44.5°C as specified in General
“Standard Methods for the Examination of Pump Flow Rate 2-speed, 9 or 15 lpm Bacteriological Testing
1/4 in. FPT Rear Discharge
Water and Wastewater” (19th Edition 1995). Pump Inlet and Outlet
Incubation
The membrane filter method or MPM method Heater
60Hz 1100 Watt
can be used. 50Hz 2200 Watt Routine
Over-Temperature Cutoff Adjustable Laboratory Use
2. AOAC determination of E. coli at 45.5°C. 9106, 912Yes
Low-Liquid Cutoff
120V Models
Sample Tempering
3. APHA, AWWA, WEF 7-Hour Fecal Coliform test Overall Dimensions 14 x 22 x 13 1/2 in.
at 41.5°C. lxwxh 35.6 X 55.9 x 34.3 cm
Working Access 10 1/4 x 11 3/4 x 8 in. Circulate to:
4. Defined Substrate Technology™ tests for E. coli lxwxd 27.3x 29.8 x 20.3 cm
- Refractometers
and total coliform at 35.0°C. Shipping Weight 43 lbs / 20 kg
- Spectrophotometers
Cat. No. 120V, 50/60Hz, 11A 8306A11B
Cat. No. 240V, 50/60Hz, 9.8A 8306A12E - Extractor
Concentrators
Note: Performance specifications determined at ambient tempera-
ture of 20°C/68°F.
®

Model 8306 supplied with


reservoir cover, bypass tube,
and male inlet/outlet tubing
Model 210, Heating Recirculator adapters for 3/8, 1/4, and
3/16 inch (.95, .63, and .47
The Model 210 recirculating heater connects to a tank or full cooling cm) tubing. Also includes 6-ft.
(1.83 meter) standard ground-
system to provide low-cost, accurate control within a frequently used ed electrical cord with U.S.
temperature range. (120V) or European (240V)
plug. Other country-specific
Ideal for routine applica- plugs available; consult
tions such as thawing plasma, PolyScience.
Model 210
tempering photographic Accessories on Pages 30
Temperature Range Ambient to 70ºC
solutions, or circulating to and 31.
Temperature Stability ±0.2ºC
an external device. The
• Low-Cost Pumping sealed reservoir allows use Reservoir Capacity 0.5 liter www.polyscience.com
and Heating with closed loop applica- Over-Temperature Adjustable
Toll Free: 800-229-7569
• Closed Loop tions. Low Liquid Cutoff Yes USA and Canada
Applications Fittings for 1/2 in. ID tubing
Overall Dimensions 8 x 9 1/2 x 8 in.
Worldwide: 847-647-0611
lxwxh 20 x 24 x 20 cm
• Make Your Own to allow for easy installa- Fax: 847-647-1155
Shipping Weight 12 lbs / 5 kg
System tion. Wetted parts are stain-
Cat. No. 120V, 60Hz, 7A 040300 e-mail:
less steel, PVC, brass, or sales@polyscience.com
nylon. Cat. No. 240V, 50Hz, 3.3A 040301

23
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 24

PolyScience

Immersion Circulators
The 7000 Series

7000 Series
Features
Model 712

• Standard Digital, Basic, or


Programmable Controller
• Up to 30 Liter/Minute
Pumping Pressure
• Control at Temperatures
Up to 200°C
• Integral Temperature and
Low-Liquid Level
Protection

The PolyScience family of The Model 7312 is shown Model 7306


in a PolyScience Acrylic
Immersion Circulators makes it tank. See pages 26 and
easy to create your own 27 for more information.
unique bath for above ambient
temperature control. Simply
combine one of our versatile
Basic, Standard Digital, or
Programmable Controllers
with any PolyScience open
bath or your own tank or
container.

Flexible Easy To Use Versatile


Need time/temperature
Rotating pump flow director Model 7306 offers three For additional temperature
programming, remote accepts 1/2 in. (13mm) ID user-defined preset buttons control flexibility, add an
probe, or data logging tubing for closed loop for frequently used tempera- optional cooling coil.
capability? applications. ture set points. See page 30.
See the PolyScience
Model 7312
Programmable Immersion
Circulator on page 26.

Adaptable Extra Protection Adjustable


Models 7306 and 712 clamp Optional protective shield The Model 7312 is built on
on to a tank's side or can be prevents sample contact an expandable bridge that
mounted on to a standard with heater element or can be suspended over a
lab stand. pump. See page 30. variety of reservoir tanks.

24
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 25

Choice of Controller
Selectable Pump Speed

Model 7306 Model 712


7000 Series
Applications

Bacteriological
Incubation
Calibration
Cell Culture
Enzyme Assays
Kinetic Research
Tempering Samples
Thawing Frozen
Specimens
Warming Culture
Media

Models 7306 and 712


supplied with 6-ft. (1.83
meter) standard grounded
Standard Digital Model 7306. The PID micro- 7306 and 712 Model Specifications electrical cord with U.S.
processor controller provides precise temperature Pumping Flow 9 or 15 lpm
(120V) or European (240V)
control and greater temperature stability. The 2- plug. Other country-specific
Tank Occupancy, approx. 6 1/2 x 4 3/4 in. / 16.5 x 12.1 cm plugs available; consult
speed pressure (simplex) pump minimizes turbu- PolyScience.
3 in. to 7 in.
lence in small tanks and provide higher flow and Immersion, minimum to maximum
7.6 cm to 17.8 cm
greater uniformity in large tanks. An adjustable Accessories on pages 30
Overall Dimensions 12 1/4 x 4 5/8 x 5 3/4 in.
flow director accepts 1/2 in. (13mm) ID tubing for hxwxd 31.2 x 11.7 x 14.6 cm and 31.
external circulation. Heater 1100 Watts (60Hz), 1600 Watts (50Hz)
®
Basic Model 712. This low-cost circulator offers Over-Temperature Cutoff Adjustable
good temperature control for routine lab applica- Low-Liquid Cutoff Yes
tions. Proportional heater control combined with Shipping Weight 9 lbs / 4.1 kg
redundant safety backup makes this analog model
an excellent value. The 2-speed pressure (simplex)
Specifications 7306 712
pump minimizes turbulence in small tanks and
Temperature Range* Ambient +5ºC to 150°C Ambient +5ºC to 100°C
can provide higher flow and greater uniformity in
large tanks. Temperature readout is via the Temperature Stability* ±0.05°C ±0.2°C
supplied thermometer (non-mercury). Controller Standard Digital Basic
Readout LED Thermometer (supplied)
Temperature Readout °C or °F N/A
Cat. No. 120V, 50/60Hz, 11A 7306A11B 73A0A11B
Cat. No. 240V, 50/60Hz, 7.5A 7306A12E 73A0A12E

* Temperature range and stability may vary depending on bath volume, surface area, insulation and
type of fluid.
See page 5 for additional controller information. Note: Performance specifications determined at ambient temperature of 20°C/68°F.

25
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 26

PolyScience

Programmable Controller
The 7000 Series

Model 7312
Model 7312 shown here in the 21 liter
Features acryllic tank. See page 27
for tank information.

• Time/Temperature
Programmability
• Variable Speed Pump
• Controllable Through
RS232 Interface
• RS232 Cable Supplied
• Remote Probe Capability
Supplied with male inlet/
outlet tubing adapters for 3/8,
1/4, and 3/16 inch (.95, .63, and
.47 cm) tubing. Also includes 6-ft.
(1.83 meter) standard grounded
electrical cord with U.S. (120V)
or European (240V) plug. Other
country-specific plugs available;
consult PolyScience.
Accessories on pages 30 and 31.
®

Model 7312 Specifications Progammable Model 7312. The full-featured PolyScience


Programmable Controller, combined with circulator placement
Temperature Range* Ambient +5º to 200ºC
flexibility, makes this “design your own bath” circulator a great value.
Temperature Stability* ±0.01ºC
Microprocessor PID control assures high accuracy and stability.
Controller / RS232 Programmable / Yes
Readout Graphic LCD The Programmable Controller features a multi-language graphic
Temperature Readout ºC or ºF
display and time/temperature programming. Ten programs can be
stored in the controller's memory; each can have up to fifty steps and
Pressure Flow (max) 30 lpm (60Hz); 22 lpm (50Hz)
can be cycled up to 99 times. An RS232 interface and remote probe
Suction Flow (max) 22 lpm (60Hz); 15 lpm (50Hz)
capability are standard. The included software supports LabView™
Tank Occupancy, approx. 7 1/2 x 8 3/4 in. drivers and Excel® macros to offer even greater programming and data
2 1/2in. to 4 1/2 in. logging convenience
Immersion, minimum to maximum
7 cm to 11.4 cm
Overall Dimensions 11 1/4 x 15 x 9 1/2 in. For internal circulation or external open and closed loop applica-
dxwxh 28.6 x 38 x 24.2 cm tions, the 7312 has a strong pressure and suction (duplex) pump with
Heater 1100 Watts (60Hz), 2200 Watts (50Hz) variable speed adjustment. The optional remote probe gives more
Over-Temperature Cutoff Adjustable accurate temperature control in applications where external circula-
Low-Liquid Cutoff Yes tion is required.
Pump Inlet and Outlet 1/4 in. FPT Rear Discharge The expandable mounting bridge spans openings from 15 to 25 in.
Shipping Weight 24 lbs / 11 kg (38.1 to 63.5 cm) across to allow placement on almost any bath
Cat. No. 120V, 50/60Hz, 11A 7312A11B container. Choose from PolyScience’s selection of stainless steel or
Cat. No. 240V, 50/60Hz, 9.7A 7312A12E acrylic baths or use your own reservoir.

* Temperature range and stability vary depending on bath volume,


surface area, insulation, and type of fluid.
Note: Performance specifications determined at ambient
temperature of 20°C/68°F.
See page 4 for additional controller information.
26
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 27

Open Bath Tanks

Open Baths

Acrylic Bath Stainless Steel Bath These open baths are recommended
for use with PolyScience Immersion
Circulators or where a container
with the corrosion resistance of
stainless steel or visibility of clear
acrylic or polycarbonate is needed.

Polycarbonate Bath

Acrylic Open Baths. Provide good visibility of immersed samples, never rust,
and cost less than stainless steel baths. The upper working limit of these acrylic
baths is 70°C. The bottoms are elevated 21/8 in. (5.4 cm) to allow placement
of low-profile magnetic stirrers or other devices beneath the bath.
Stainless Steel Baths. Seamless, insulated, and coated with a durable epoxy
powder finish. Carrying handles included. These baths can be used for fluid
temperatures up to 300°C.
Polycarbonate Bath. Provides a broad working temperature range (-40° to
+98°C). Stackable design fits standard racks and carts.

Acrylic Baths Temperature Limit 70°


Capacity 8 liter 16 liter 21 liter
Working Access 18 x 5 x 7 1/2 in. 18 x 10 x 7 1/2 in. 18 x 13 1/8 x 7 1/2 in.
lxwxd 45.7 x 12.7 x 19 cm 45.7 x 25.4 x 19 cm 45.7 x 33.3 x 19 cm
Shipping Weight 7 lbs / 3 kg 9 lbs / 4 kg 11 lbs / 5 kg
Cat. No. 040700 040705 040710

Stainless Steel Baths Temperature Limit 300°


Capacity 13 liter 28 liter
Working Access 9x 11 3/4
x 7 3/4
in. 11 3/4 x 19 1/2 x 7 3/4 in. www.polyscience.com
lxwxd 22.9 x 29.8 x 19.7 cm 29.8 x 49.5 x 19.7 cm
Shipping Weight 15 lbs / 7 kg 25 lbs / 11 kg
Toll Free: 800-229-7569
USA and Canada
Cat. No. 040510 040520
Worldwide: 847-647-0611
Polycarbonate Bath Temperature Limit 98°C Fax: 847-647-1155
Capacity 18 liter e-mail:
Working Access 12 x 18 x 9 in. sales@polyscience.com
lxwxd 30.5 x 45.7 x 22.9 cm
®
Shipping Weight 2 lbs / 0.9 kg
Cat. No. 040904 27
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 28

PolyScience

PolyScience Coolers
The KR and VLT Series

VLT 60 and VLT 100 KR 50, KR 80 and KR 60


KR and VLT
Features

• Continuous Cooling
to Temperatures as Low
as -100˚C
• Choice of Fixed or
Adjustable Set Point
• Low-Cost Operation -
An Economical
Alternative to Dry Ice PolyScience VLT and KR Series Coolers can be used to achieve low-temperature capability with non-refrigerated
or Liquid Nitrogen circulators or boost the cooling capacity of refrigerated circulators.
• Designed For VLT Series Coolers are available with immersion probes only. They are capable of achieving cooling temperatures
Continuous Use as low as -100°C. VLT 100 models feature a digital temperature display and may be ordered with or without
temperature control; non-temperature controlled models operate at maximum cooling. The VLT 60 also operates
at maximum cooling (-60°C). It does not display temperature.
KR Series Coolers are available in both immersion probe and flow-through models. They are capable of achieving
cooling temperatures as low as -45°C. All KR models are designed to run at maximum cooling; temperature
control must be provided by an external circulator. The flow-through model must be used in-line with a circula-
tor pump. Because of its high cooling efficiency, an anti-freeze solution is required in the circulating system.
Immersion Probe style coolers (VLT Series, KR 50, and KR 80) are excellent for trapping and Dewar type
applications and can be used to reduce the expense of using dry ice or liquid nitrogen. PolyScience offers
several different styles of immersion probes; all have an insulated flexible hose that allows convenient
placement of the cooling probe.

Rigid Coil Flexible Cold Finger

Immersion Probe Dimensions


3 in. Rigid Coil Probe 1.5 in. 1.75 in.
Cold Finger Probe Flexible Probe
Insulated Flexible Hose (VLT 100 Series, Rigid Coil Probe Rigid Coil Probe
(VLT 100) (VLT 100-NC) (VLT 100 Series)
KR 80) (VLT 60) (KR 50)

VLT 100 — 2.83 in. (7.14 cm)


0.625 in.
Diameter x VLT 60 — 1.5 in. (3.81 cm) 3 in. (7.62 cm) 1.5 in. (3.81 cm) 1.75 in. (4.44 cm) 0.75 in. (1.91 cm)
(1.59 cm)
KR Series — 1.5 in. (3.81 cm)
15 in. (38.1 cm) 15 in (38.1 cm) 15 in. (38.1 cm)
VLT 100 — 6 ft. (1.83 m) exposed length; exposed length; exposed length; 8.0 in. 3.75 in. 15 in.
Length xx VLT 60 — 4 ft. (1.22 m) 8.75 in. (22.2 cm) 4.5 in. (11.4 cm) 7.5 in. (19.05 cm) (20.3 cm) (9.53 cm) (38.1 cm)
x KR Series — 4 ft. (1.22 m) coil length coil length coil length

28
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 29

Immersion Probe and


Flow-Through Styles

Immersion Probe Models Cooling Flow-Through Model Cooling

-40˚ C 40˚C 30˚C


KR and VLT
-50˚ C 30˚C 20˚C
Applications
20˚C 10˚C
-60˚ C

0˚C
-70˚ C
10˚C
Cooling Exothermic
VLT 100 0˚C -10˚C Reactions
-80˚ C VLT60
-10˚C -20˚C
Freezing Point
KR50
-90˚ C
-20˚C -30˚C Determinations
KR80 KR60
-100˚ C -30˚C -40˚C
0 15 30 45 60 75 90 105
Impact Testing
0 5 10 15 20 25 30 35 40 0 10 20 30 40 50 60 70

Time In Minutes
Lyophilization
Note: Test data represents 3 liters of 50% water, 50% ethylene glycol mixture. Quick Cooling
Replace Dry ice
VLT Series Specifications VLT 100 VLT 100-NC VLT 60
Temperature Control Yes No No Solvent Traps
Temperature Range -40° to -85°C -40° to -100°C -20° to -60°C Vacuum Traps
Temperature Readout Digital Display None
150 watts @ -40°C
75 watts @ -20°C
Cooling Capacity 120 watts @ -60°C
0 watts @ -60°C
70 watts @ -80°C
Compressor Two; 1/2 HP each One; 1/4 HP VLT and KR Series Coolers
Overall Dimensions 21 x 15 x 20.125 in. 9 x 10 x 11 in. supplied with 6-ft. (1.83
(H x W x D) 53.3 x 38.1 x 51.1 cm 22.9 x 25.4 x 22.9 cm meter) standard grounded
Shipping Weight (Approximate) 162 lbs./ 73.5 kg 49 lbs./22 kg electrical cord with U.S.
Standard Cooling Probe 3 in. Rigid Coil 1.5 in. Rigid Coil (120V) or European (240V)
plug. Other country-specific
Optional Cooling Probes Cold Finger None
Flexible
plugs available; consult
PolyScience. KR 60 Flow-
Electrical 120 V, 60 Hz, 11.5A 120 V, 60 Hz, 5A
240 V, 50 Hz, 7.5A 240 V, 50 Hz, 2.5A Through Coolers supplied
3 in. Rigid Coil - P85C6A101B 3 in. Rigid Coil - P10N6A101B with 3/8 inch male adapters
Cat. No. / Probe Style with 1/2 inch barbed hose
(120V) Cold Finger - P85C8A101B Cold Finger - P10N3A101B 1.5 in. Rigid Coil - 070960
Flexible - P85C4A101B Flexible - P10N4A101B connector.
Cat. No. / Probe Style 3 in. Rigid Coil - P85C6A102E 3 in. Rigid Coil - P10N6A102E Accessories on pages 30
(240V) Cold Finger -P85C8A102E Cold Finger - P10N3A102E 1.5 in. Rigid Coil - 070965
Flexible - P85C4A102E Flexible - P10N4A102E and 31.

KR Series Specifications KR 50 KR 80 KR60


Operating Temperature
-35° to +40°C -45° to +40°C -25° to +40°C
Range

Style Immersion Probe Flow Through


Temperature Control No - Fixed at -35°C No - Fixed at -45°C No - Fixed at -25°C
Temperature Readout None www.polyscience.com
975 watts @ 20°C 1050 watts @ 20°C 745 watts @ 20°C
Cooling Capacity 0Toll Free: 800-229-7569
140 watts @ -30°C 265 watts @ -30°C 260 watts @ -10°C
Probe Style 1.75 in. Rigid Coil 3 in. Rigid Coil NA USA and Canada
Inlet & Outlet Size NA NA 3/8 in. FPT Worldwide: 847-647-0611
Dimensions (H x W x D) 14 x 14 x 17 in. (35.6 x 35.6 x 43.2 cm) Fax: 847-647-1155
Shipping Weight 76 lbs./34 kg 78 lbs./35.4 kg 73 lbs./33.1 kg
e-mail:
Cat. No. 120 V, 60 Hz, 5A 070850 070880 070860 sales@polyscience.com
Cat. No. 240 V, 50 Hz, 2.5 A 070855 070885 070865
Note: Cooling capacity (Watts x 3.41) = BTU/hr. Performance specifications determined at ambient temperature of 20°C/68°F. For 50Hz units, derate
cooling capacity by 17%.
29
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 30

PolyScience

Accessories

Cooling Coils Thermometry Calibration Reservoir


For auxiliary cooling of circulators. 18-inch (45.7 cm) deep companion
The stainless steel coil, when reservoir converts Model 9712
connected to a water source, per- Refrigerating/Heating Circulator into
a Thermometry Calibration System.
mits more rapid cool down from
Use the 9712’s 13 liter reservoir to
high temperatures or better control calibrate up to 20 standard length
when operating close to ambient temperature measurement devices;
temperatures. Not recommended use the 4.75 liter companion reser-
for use in circulator baths where voir to calibrate up to 10 immersion
fluid temperature exceeds the boiling point of water. thermometers. Includes lids with
For Heating Circulators Cat. No. 060300 integral thermometer holders for
both reservoirs. Note: The addition of the calibration reser-
For Model 712 and 7306 Cat. No. 050300 voir may decrease the operating temperature range
achievable with the Model 9712 to approximately -35° to
150°C.
Protective Shield for Immersion Circulators
Cat. No. 040512
For Standard Digital and Basic
Immersion Circulators. Stainless Tubing and Tubing Accessories
steel grid prevents sample contact
High-Temperature Tubing
with heater element or pump.
Attaches and removes easily for 3 ft. (.93m) flexible Teflon® lined, stainless steel over-
cleaning. braid tubing with 1⁄4 in. (.63 cm) swivel fittings. Max.
Cat. No. 510-451 temperature 300°C. Cat. No. 060310

High-Temperature Viton Bypass Tubing


Remote Probe 6 inch (15.2 cm) length. Includes internal spring and gear-
For circulators with type hose clips. Max. temperature 200°C. Cat. No. 510-495
Programmable Controller.
Permits point of control to be Low-Temperature Insulated Tubing
switched from inside pro- Minimizes temperature loss from a circulator to external
grammable circulator bath to device. 6 ft. (1.9 m) of 1/2 in. (1.27 cm) ID Buna N tub-
a remote location, such as an ing with foam insulation. Cat. No. 060312
open tank. Compensates for
heat loss through tubing Tubing Clamp
between the circulator and 3 mm to 13 mm tubing Cat. No. 060304
the control point. Platinum RTD sensor with stainless
steel sheath 5/32 dia. x 6 in. long (.4 dia. x 15.2 cm). Brass Reducing Adapters
One inch (2.54 cm) rubber coupling connects sheath to 8 mm ID (Set of 2) Cat. No. 060305
flexible cable. Probe cable ends in DB9 female plug. 3 mm (Set of 2) Cat. No. 060306
10 ft. (3 m) Cat. No. 060101
25 ft. (7.6m) Cat. No. 060105 Buna N Tubing
50 ft. (15.25m) Cat. No. 060110 8 mm ID per yard (.9m) Cat No. 060307
Custom lengths available on special order. 13 mm ID per yard (.9m) Cat No. 060308

Insulation
8 mm tubing per yard (.9m) Cat. No. 060309
13 mm tubing per yard (.9m) Cat. No. 060311
30
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 31

Accessories

Accessories
Digital-to-Analog Adapter Glass Thermometer (non-mercury)
For circulators with Programmable or Advanced -20° to 150°C, 1°C Cat. No. 099590
Digital Controller when direct digital control is
not required. Connects to the RS232 port and pro- Concentrated Bath Cleaner
vides 10mv/degree analog signal for external
monitoring or control. A concentrated liquid for
cleaning and removing rust and
Cat. No. 062120
mineral deposits from stainless
steel and plastic baths. Use at
Lab Algicide elevated temperatures. Helps
General purpose lab algicide remove existing algae prior to
helps keep water baths clean, treatment with Lab Algicide. 1
odor free, and resistant to black oz. (29.6 ml) treats approxi-
algae. Stainless steel compati- mately 2 gallons (8 liters).
ble. Use 20 drops per gallon to
prevent algae growth. 8 oz. (236 8 oz. bottle Cat. No. 004-300050
ml) dispenser bottle treats 16 oz. bottle Cat. No. 004-300052
approximately 200 gallons (757
liters).
8 oz. bottle Cat. No. 004-300040

Bath Fluids
Low Temperature - Dynalene HC-50™ combines the low-temperature
performance of synthetic organic and silicone fluids while extending the
properties of familiar aqueous-based glycols. Excellent low-temperature per-
formance without toxicity or risk to the environment, equipment, or personnel.
High Temperature - Dow Corning® Silicone Heat Transfer Fluids provide
superior thermal stability over their temperature ranges. Check bath
system compatibility before using. Compatible with stainless steel; not com-
patible with Buna or natural rubber.
Temperature Freeze
Range Point Viscosity Quantity Cat. No.

Dynalene HC™ -53° to 60°C -56°C 3.6 cSt @ 0°C 1 gallon 060330
-63° to 140°F -68°F 15.1 cSt @ -40°C 3.79 liters

Dow Corning® 510 50° to 150°C -70°C 50 cSt @ 25°C 1 gallon 060326
www.polyscience.com
122° to 302°F -94°F 3.79 liters
Toll Free: 800-229-7569
Dow Corning® 550 100° to 200°C -50°C 125 cSt @ 25°C 1 gallon 060327
USA and Canada
212° to 392°F -58°F 3.79 liters
Worldwide: 847-647-0611
Dow Corning® 710 150° to 250°C -22°C 500 cSt @ 25°C 1 gallon 060328
302° to 482°F -7.6°F 3.79 liters Fax: 847-647-1155
Due to high viscosity, Silicone Fluids 510, 550, and 710 are not recommended for use below 90°C. e-mail:
Dow Corning fluids are produced by and registered TMs of Dow Corning Corporation. sales@polyscience.com
Dynalene HC is a registered TM of Advanced Fluid Technologies, Inc.

31
21238_GRAP_Circulator_A3:CirculatorR1.qxd 3/2/09 2:48 PM Page 32

www.polyscience.com

PolyScience Toll-Free 1-800-229-7569,


847-647-0611, Fax 847-647-1155
6600 West Touhy Avenue, Niles IL 60714 USA

PolyScience a leading manufacturer of:


• Refrigerated Circulators
• Heating Circulators
• Immersion Circulators
• Chillers
• Recirculating Coolers
• Water Baths
Along with custom-ordered temperature control equipment for
industrial and laboratory use.
We have been providing customers worldwide with precision
temperature control equipment since 1963 and serve a diverse
range of industries.
Beyond our comprehensive line of standard temperature control
products, PolyScience also offers custom designed heating and
cooling equipment. If you have a special application or specific
product need, our experienced design, engineering, and technical
staff will be happy to review your application and design a prod-
uct that meets your exact requirements.
PolyScience is an ISO 9001:2000 Certified Company

Ask for these PolyScience Product brochures

PolyScience offers six models of PolyScience chillers have a new PolyScience offers the new
water baths with either digital Noise Reduction Technology DURACHILL™ line of Industrial
or analog control. Shaking that offers quiet but powerful Capacity Chillers. They provide
water bath systems are also cooling operation. Compact and high performance cooling even
available portable, they are ideal for a in high ambient conditions.
wide range of laboratory and
industrial cooling applications.

PolyScience is a registered TM of Preston Industries, Inc.


Prices and specifications are subject to change without notification.
010142 2.5M Rev. 2/09

You might also like