0% found this document useful (0 votes)
473 views47 pages

Zinga Catalog 17th Edition

The Zinga Filtration Group's 17th Edition catalog highlights their extensive range of high-quality filtration systems and accessories for the mobile hydraulic market, emphasizing their leadership in oil cleanliness and performance. The catalog features various products, including spin-on filters, tank-top filters, and pressure filters, all designed to meet demanding corrosion resistance requirements. ZingaTect coating is presented as a key innovation for enhanced protection in harsh environments.

Uploaded by

carlos grajales
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
473 views47 pages

Zinga Catalog 17th Edition

The Zinga Filtration Group's 17th Edition catalog highlights their extensive range of high-quality filtration systems and accessories for the mobile hydraulic market, emphasizing their leadership in oil cleanliness and performance. The catalog features various products, including spin-on filters, tank-top filters, and pressure filters, all designed to meet demanding corrosion resistance requirements. ZingaTect coating is presented as a key innovation for enhanced protection in harsh environments.

Uploaded by

carlos grajales
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 47

Hydraulic Oil Filtration

17TH EDITION

A Safer, Healthier and More Productive World


Filtration Group Corporation

Zinga Filtration Group Catalog


17TH EDITION
As a part of Filtration Group, Zinga is a global leader in filtration for agriculture and construction
providing filtration and reservoir accessory product solutions for the mobile hydraulic market.
We lead the industry in developing extensive, award-winning product lines of filtration solutions
that improve oil cleanliness, maximize performance and meet warranty levels for reliability.

Phone 608.524.4200 Fax 608.524.4220


www.filtrationgroup.com

© 2017 All rights reserved.


FGZ-058022117-01
2
Corrosion Never Sleeps Zinga Filtration Group 17th Edition TABLE OF CONTENTS
CONTENTS SERIES DESCRIPTION PAGE

Zinga has been manufacturing high quality filtration SPIN-ONS


systems and accessories for more than 30 years.
ZingaTectTM coating is stronger than conventional Spin-On Heads — BF Ports: 3/8” NPTF; 9/16”-18 UN (SAE-6); Flows up to 7 GPM - 1
Single Elements 200 PSI Max; Spin-on Filters: BE (3.1” Dia. x 3/4”-16)
anodizing, providing the best corrosion protection Filter Elements BE & ZBE 10, 25 & 40 Micron (3.1” Dia. x 3/4”-16); Heads: BF Series 2
available. If your application requires the toughest Spin-On Heads — ZAF05, 07, Ports: 1/2” NPTF Thru 1 5/16”-12 UN (SAE-16); Flows up to 32 3-5
Single Elements 10 GPM - 250 PSI Max.; Spin-on Filters: AE (3.7” Dia. x 1”-12)
protection for the harshest environments, specify
Tank-Top
Filter Elements AE 3, 10 & 25 Micron (3.7” Dia. x 1”-12); Heads: 6
ZingaTect coating. Need more information? Contact us. ZAF Series
Filter Elements ZAE 3 & 10 Micron (3.8” Dia. x 1”-12); Heads: ZAF Series 7
Spin-On Heads — VAF & VE-10 Port: 1” NPTF; Flows Up To: 32 GPM — 250 PSI Max. 8
Single Elements
If you have corrosive salt applications requiring a proven coating for your Spin-On Heads — SF100, 120, Ports: 1” NPTF Thru 1 5/8”-12 UN (SAE-24); Flows up to 80 9 - 12
Filler/Breather Single Elements 122, 150 GPM - 200 PSI Max
exposed hydraulic filter, ZingaTect Coating is now a viable option.
Spin-On Heads — MF Modular Inline; Ports: 1 1/2” NPTF, 1 7/8”-12UN (SAE-24); 2” 13 - 14
Multiple Elements 4-Bolt Flange; Flows up to 120 GPM - 200 PSI Max; Spin-On
Filters: SE & LE (5.1” Dia. x 1 1/2”-16)
ZingaTectTM Coating Performance Benefits: Spin-On Heads — ZDF Modular Side-by-Side; Ports: 1 1/2” NPTF, 1 7/8”-12UN 15 - 16
Multiple Elements (SAE-24); 2” 4-Bolt Flange
• Improves product aesthetics
Spin-On Heads — DHF Ports: 3/4” NPTF Thru 1 5/16”-12UN (SAE-16); Flows up to 35 17 - 18
• Resists deterioration from acid and alkaline solutions Single Elements GPM - 500 PSI Max.; Spin-on Filters: ME (3.7” Dia. x 1 3/8”-12)
• Fights filiform corrosion Spin-On Heads — DF15 Over/Under; Ports: 1 1/2” NPTF, 1 7/8”-12UN (SAE-24); 2” 19
Multiple Elements 4-Bolt Flange; Flows up to 120 GPM - 200 PSI Max.; Spin-On
• Is RoHS, ELV, and WEEE compliant Filters: SE & LE (5.1” Dia. x 1 1/2”-16)

• Combines conventional anodizing with a proprietary sealing process Filter Elements SE & LE 3, 10 & 25 Micron (5.1” Dia. x 1 1/2”-16); Heads: SF, DF, MF, 20
Spin On MFT, & ZDF Series
to produce a finish coating that resists creep corrosion while exhibiting Filter Elements ZSE & ZLE 3 & 10 Micron (5.1” Dia. x 1 1/2”-16); Heads: SF, DF, MF, MFT, 21
& ZDF Series
superior adhesion qualities
Spin-On Heads — HF Ports: 3/4” NPTF Thru 1 5/16”-12UN (SAE-16); Flows up to 40 22
• Highly recommended when corrosion resistance conditions are demanding Single Elements GPM - 400 PSI Max.; Spin-on Filters: HE (3.7” Dia. x 1 1/2”-16)
Filter Elements HE 3 &10 Micron (3.7” Dia. x 1 1/2”-16); Heads: HF Series 23
Filter Elements ZME 5 & 16 Micron (3.7” Dia. x 1 3/8”-12); Heads: DHF Series 24
Property Aluminum Alloys

Appearance Gloss to semi-gloss


PRESSURE
Hardness (pencil) (ASTM B 3363) 3H-5H

Thickness (Eddie Current) 0.5 – 2.0 mils


Spin On Cartridge Filter C16 Cartridge Filter for Common Cavity C16-2; Flows up to 12 25
Salt Spray (with cross hatch) > 1000 hours GPM, 3,000 PSI
Manifold Cartridge Filters CF & CE Cartridge Element with By-pass Plug; Flows up to 30 GPM, 26
Acid Resistance (H2SO4 5% @ 68∞ F) > 300 hours 3,000 PSI
Alkaline Resistance (NaOH 5% @ 68∞ F) > 300 hours Zinga ProTect Shroud High-Pressure Filter CF90 Flows up to 12 GPM, 3,000 PSI; Ports: 1/2” NPTF & SAE-8 27
Harsh Environment Protection
Solvent Resistance ( MIBK) > 20 double rubs FG03Q combines filter gasket Pressure Filter Elements G Zinga Synthetic Z-Glass Media; Application: P3000 Series 28
Pressure Filters
with a protective shroud top.
QUV UVB Test (w/ no visible changes) 500 hours In-Line Pressure Filters HP3000 Flows up to 60 GPM, 3,000 PSI; Ports: 1” NPTF, 1 1/16”-12 29 - 30
UN (SAE - 12) & 1 5/16”-12 UN (SAE - 16)
Pressure Filter P3000 Flows up to 30 GPM, 3,000 PSI; Port: 1 1/16”-12 UN (SAE - 12) 31 - 32
Minimum orders apply for ZingaTectTM Coating.
Pressure Filter W1200 Flows up to 120 GPM, 1,200 PSI; Ports: 1 1/4” NPTF, 1 5/8”- 33 - 34
12 UN (SAE-20), 1 7/8”-12 UN (SAE-24)

Quality, high-performance cost-effective 608.524.4200


filtration systems since 1976 Zinga.com
Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
II III
TABLE OF CONTENTS Zinga Filtration Group 17th Edition Zinga Filtration Group 17th Edition TABLE OF CONTENTS
CONTENTS SERIES DESCRIPTION PAGE CONTENTS SERIES DESCRIPTION PAGE

TANK-TOP Breather FBR 1 1/2” & 3” Raised Aluminum Body, 10 Micron; Bayonet
Mount; Options: Relief Valve, Dipstick, Basket, Nylon Cap
62

Breather TB BE & AE Spin-On Series Steel Adapter Fittings; Convert Spin- 63


Tank-Top Filter SLF1 Flows up to 25 GPM, 100 PSI; Ports: 1/2” & 3/4” NPTF; SAE & BSP 35 On Element to Tank Breather; 3/4” to 1 1/4” NPT Male Mount

Filter Elements SLE1 & 36 Breather TBN310 3-Micron Spin-On Element; 3/4” NPT Plastic Male Mount 64
Cellulose and Z-Glass Media, Ports: 1/2” & 3/4” NPTF; SAE-8
ZSLE1 & SAE-12 (Integral); Interchange for Competitor 310 Products

Tank-Top Filter SLF2 37 Filter Gauges GV & CI Filter Condition Indicator - Color Vacuum Gauge; 2” Dia, 1/8 65
Flows up to 40 GPM, 100 PSI; Ports: 3/4” & 1” NPTF; SAE-12
& SAE-16 NPTF Male Mount; Suction Line Filters with 3 & 5 PSI By-pass

Filter Elements SLE2 & 38 Filter Gauges GVL & CIL Stainless Steel Glycerin-Filled Filter Gauges with 3 & 5 PSI 66
Cellulose & Z-Glass Media; 3, 10 & 25 Micron
ZSLE2 By-pass

Tank-Top Filters TR & TS Flows up to 96 GPM, 100 PSI; Ports: 1 1/4" & 1 1/2" NPTF, 1 39 - 40 Filter Gauges LG Pressure Gauges, Glycerin Filled; 2.5” Dia., 1/4” NPTF Male, 67
5/8" - 12 UN (SAE - 20), 1 7/8" - 12 UN (SAE - 24) & 1 1/4" BSP 4 Mount Options; Gauge Pressures up to 10,000 PSI

Tank-Top Filter SRF Flows up to 83 GPM, 100 PSI; Ports: 1 1/4" & 1 1/2" NPTF, 1 41 - 42 Sight-Level Guages SG Sight Level Gauge, UV Resistant Polymer; Options: Ther- 68
5/8" - 12 UN (SAE - 20), 1 7/8" - 12 UN (SAE - 24) & 1 1/4" BSP mometer, Aluminum & Plastic Guards; 3”, 5”, & 10” Lengths,
SAE & Metric Hardware
Tank-Top Filter RF & WF Flows up to 96 GPM, 100 PSI / 500 PSI; Ports: 1 1/4" & 1 43 - 44
1/2" NPTF, 1 5/8" - 12 UN (SAE - 20), 1 7/8" - 12 UN (SAE - Oil Eye OE-1 Oil Level Indicator; Steel Weld Collar; High-Temperature, 68
24) & 1 1/4" BSP UV-Resistant Polymer Window

Filter Elements SRE & ZSRE Cellulose, SS Mesh, Aqua-Zorb & Z-Glass; 3, 10, 25 & 141 Micron 45 Indicators DP03, 04, Filter Condition Indicator - Differential Pressure; Cartridge 69 - 70
05, 06 Style, Visual & Electrical; In-Line Filter Applications with ΔP
Filter Elements RE & ZRE Cellulose, SS Mesh, Aqua-Zorb & Z-Glass; 3, 10, 25 & 141 Micron 46 Ports in Filters
Tank-Top Filter WF2 Flows up to 300 GPM, 300 PSI; Ports: 2” NPTF, 2” to 3” 47 - 48 Adapter FT Male NPT to Hose Barb Adapters; Steel with Zinc Plate Finish 71
4-Bolt SAE Flange St&ard; 1/2” to 4” NPT
Filter Elements WE & ZWE Cellulose, SS Mesh, Aqua-Zorb & Z-Glass; 3, 10, 25 & 141 Micron 49 Clamp HC T-Bolt Type Hose Clamps; Self-Locking Nut; 1.19” to 4.81” 71
Clamping Ranges
Filters & Elements SRF, RF, Typical Installations 50
WF-2
VALVES
STRAINERS
Check Valves BRV Back Pressure Inducing Valve; 3, 5, 15, & 25 PSI Settings; 72
3/4”x 1 1/4” NPTF up to 2” x 3” NPTF Reducers
Tank Filter SS & MS Internal Bushing Mount; Ports: 3/8” to 6” NPTF 51
Check Valves LRV In-Line Check Valves; 2, 6, 20, 40, & 60 PSI Settings; 3/4” up 73
Tank Filter TF External Reducer Bushing Mount; Ports: 3/8” to 4” NPTF 52 to 3” NPTF & SAE-12 up to SAE-24
Tank Filter TFS External Steel Reducer Bushing Mount; Ports: 1/2” to 3” NPTF 53 Check Valves RV In-Tank Return Line Check Valves; 1/2 PSI Setting 74
Tank Strainer (O-Ring) TF & TFS External O-Ring Seal Mount; Ports: SAE-20 to SAE-32 54
Tank Filter (Male) TF External Nipple Mount; Ports: 2” to 2 1/2” NPTF 55
MISC.
Tank Filter BTF External Bushing Mount; Ports: 3/4” to 1 1/4” Hose 56

Reservoir Cover RCA Reservoir Covers with Integral FIller Breather, Tank-Top FIlter, 75
TANK DIFFUSERS & Drain Ports
Reservoir Cover RCB Reservoir Covers with Integral FIller Breather, Tank-Top FIlter, 76 - 77
& Drain Ports
Tank Diffusers TD-PMI Internal Bushing Mount; Ports: 3/8” to 6” NPTF 57
Tank Diffusers (O-Ring) TD-PME External Reducer Bushing Mount; Ports: SAE-20 & SAE-24 58
APPENDIX
ACCESSORIES
Particle Size & Measurement of Filter Efficiency 78
ISO Cleanliness Level Codes 79
Breather RB Aluminum Body, 10 Micron; 3/4” NPT Male Mount; Options: 59 Zinga Media Types 80
Relief Valve, Plastic Cap
Filter Application Guidelines 81
Breather WSFB Stamped Steel Construction, 10 Micron; Weather Resistant 60
Cap (Black), Dipstick, Basket; Bayonet Mount, Stamped Steel Guideline / Formulas / Conversions 82
Breather FB Aluminum Body, 10 Micron; Bayonet Mount w/ Integral Lock 61 Velocity Chart for Pipe-Tube-Hose 83
Tab; Options: Relief Valve, Dipstick, Basket, Nylon Cap

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
NOTES

SPIN-ONS 1

PRESSURE 25

TANK-TOP 35

STRAINERS 51

TANK DIFFUSERS 57

ACCESSORIES 59

VALVES 72

MISC. 75

APPENDIX 79
1 2

BF SERIES BE & ZBE SERIES


SPIN-ONS

SPIN-ONS
SPIN-ON FILTER HEADS SPIN-ON FILTER ELEMENTS
FOR USE WITH BF SERIES FILTER HEADS
Flows Up To: 7 GPM (Return) 2 GPM (Suction)
Port Sizes: 3/8” NPTF; 9/16”-18 UN (SAE-6)
Diameter: 3.1”
Pressure: 200 PSI Max. Operating
Mounting Thread: 3/4” - 16 UN
Temperature: Up to +250°F Operating
Overall Height: 3.4”
Applications: Petroleum-based fluids.
Operating Pressure: 200 PSI Max. Operating
Consult factory for synthetic fluids.
∆Pmax Cellulose 50 PSID without by-pass valve
Temperature: Up to +250°F Operating
Applications: Petroleum-based fluids.

MOUNTING HOLES
(2) 1/4"-20 X 3/8" DEEP OR
(2) M8 X 1.25 X 9.5MM DEEP
WITH BSP PORTS Part Particle Efficiency Can Color / Media Internal
Number Size (See Below) Imprint Type By-pass
1.5" BE100 10 Micron ß9µ(c) = 2 White / Red Cellulose None
BE1018 10 Micron ß9µ(c) = 2 White / Red Cellulose 18 PSID
INLET & OUTLET PORT SIZES: BE2525 25 Micron ß17µ(c) = 2 White / Black Cellulose 25 PSID
2 5 3/8” NPTF OR 9/16”-18 UN(SAE-6)
1.6" BE400 40 Micron ß22µ(c) = 2 White / Black Cellulose None

1/8" NPTF GAUGE PORTS (OPTIONAL)


INLET PRESSURE LOCATION:
2 (RETURN LINE)
OUTLET PRESSURE LOCATION: 5 (SUCTION LINE)
.56"

1.12"

BE ELEMENTS 3/4"-16 THREAD


4.5" Average Pressure Drop Through Clean Filter
ZBE ELEMENTS
Assembly With 150 SUS Oil At 105°F.
Application Data:
• Reference:
ßXµ(c) = 2 represents 50% efficiency at Particle Size (Nominal Rating)
ßXµ(c) = 75 represents 98.7% efficiency at Particle Size (Absolute Rating)
• Application: Petroleum-based fluids. Consult factory for synthetic fluids.
3.1" ALLOW .4" FOR
ELEMENT REMOVAL • Caution: Do not use BE Series filter elements on internal combustion engines.

BE & ZBE Element: See Page 2

Commonly Ordered Configurations


BF030
BF060

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
3 4

ZAF05 SERIES ZAF07 SERIES


SPIN-ONS

SPIN-ONS
SPIN-ON FILTER HEADS SPIN-ON FILTER HEADS
Flows Up To: 22 GPM (Return) 5 GPM (Suction)
Port Sizes: 1/2” NPTF; 3/4”-16 UN (SAE-8)
Pressure: 250 PSI Max. Flows Up To: 25 GPM (Return) 9 GPM (Suction)
Temperature: Up to +250°F Operating Port Sizes: 3/4” NPTF; 1 1/16”-12 UN (SAE-12)
Applications: Petroleum-based fluids. Pressure: 250 PSI Max. Operating
Consult factory for synthetic fluids. Temperature: Up to +250°F Operating
Applications: Petroleum-based fluids.
Consult factory for synthetic fluids.

3 1/8” N.P.T.F. GAUGE PORTS (OPTIONAL)


INLET PRESSURE LOCATIONS:
1 2 3 (RETURN LINE)

OUTLET PRESSURE LOCATION:


OUTLET
INLET

FLOW
5 (SUCTION LINE)

5 INLET & OUTLET PORT SIZES:


1/2" NPTF or 3/4"-16 UN(SAE-8)
2
1
(2) 1/4”-20 x 3/8”
3.50” 1.50”
DP. MTG. HOLES
.96” .96”

.70”
1.12"
1.31”
HEX Cellulose Media Cellulose Media

.20”
1”-12 THD. 25 25

7.1”
20 20
ZAE-25

Pressure Drop (PSI)


ZAE-25
Pressure Drop (PSI)

AE ELEMENTS
10.0” ZAE ELEMENTS 15 ZAE-10
AE-L ELEMENTS 15 ZAE-10
AE Elements
ZAE-10L ZAE-10L
ZAE Elements 10
10

5
5
Z-Glass Media
Z-Glass Media 0
0 0 10 20 30 40
0 10 20 30 40 Flow Rate (GPM)
Flow Rate (GPM) AE-L Elements
Average Pressure Drop Through Clean Filter
ALLOW .63 INCH CLEARANCE Average Pressure Drop Through Clean Filter Assembly With 150 SUS Oil At 105° F.
3.7” DIA. FOR ELEMENT REMOVAL
(BOTH ELEMENT SIZES) Assembly With 150 SUS Oil At 105° F.

Commonly Ordered Configurations AE & ZAE Element Data: See Pages AE & ZAE Element Data: See Pages
ZAF05000 6&7 6&7
ZAF05300
Commonly Ordered Configurations
ZAF05500
ZAF07000
ZAF08000
ZAF072513
ZAF08300
ZAF11000
ZAF08500
ZAF112513

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
5 6

ZAF10 SERIES AE SERIES


SPIN-ONS

SPIN-ONS
SPIN-ON FILTER HEADS SPIN-ON FILTER ELEMENTS
FOR USE WITH ZAF SERIES FILTER HEADS
Flows Up To: 32 GPM (Return) 14 GPM (Suction) Diameter: 3.8”
Port Sizes: 1” NPTF; 1 5/16”-12 UN (SAE-16) Mounting Thread: 1” - 12 UN
Pressure: 250 PSI Max. Operating Operating Pressure: 250 PSI Max. Operating
Temperature: Up to +250°F Operating ∆Pmax: 50 PSID
Applications: Petroleum-based fluids. Temperature: Up to +250°F Operating
Consult factory for synthetic fluids. Applications: Petroleum-based fluids.

3 1/8” N.P.T.F. GAUGE PORTS (OPTIONAL)


INLET PRESSURE LOCATIONS:
1 2 3 (RETURN LINE)

OUTLET PRESSURE LOCATION:


Part Particle Nominal Absolute Can Color / Media Free Water Overall
OUTLET
INLET

FLOW
5 (SUCTION LINE)
Number Size Rating Rating Imprint Type Absorption Height
INLET & OUTLET PORT SIZES: AE03 3 Micron ß<4µ(c) = 2 ß7µ(c) = 75 White / Green Cellulose 5.8”
5 1” NPTF OR 1 5/16”-12 UN(SAE-16)
2 AE03AZL 3 Micron ß5µ(c) = 2 ß24µ(c) = 75 White / Orange Aqua-Zorb 7.2 oz 8.5”
1
(2) 1/4”-20 X .31”
Cellulose Media AE10 10 Micron ß11µ(c) = 2 ß25µ(c) = 75 White / Red Cellulose 5.8”
3.65” DP. MTG. HOLES 1.50”
.96” .96” AE10AZ 10 Micron ß8µ(c) = 2 ß30µ(c) = 75 White / Orange Aqua-Zorb 4.1 oz 5.8”
AE10L 10 Micron ß<4µ(c) = 2 ß19µ(c) = 75 White / Red Cellulose 8.5”
.91”
1.74”
1.83”
HEX. AE100 141 Micron - - White / Blue Stn. Steel Mesh 5.8”
.51” 25
AE25 25 Micron ß16µ(c) = 2 ß31µ(c) = 75 White / Black Cellulose 5.8”
20
ZAE-25
Pressure Drop (PSI)

1”-12 THD.
7.7” 15 ZAE-10

ZAE-10L
10
AE Elements 10.5”
ZAE Elements
5
Z-Glass Media
Application Data:
0
0 10 20 30 40 • Reference:
Flow Rate (GPM) ßXµ(c) = 2 represents 50% efficiency at Particle Size
AE-L Elements
ßXµ(c) = 75 represents 98.7% efficiency at Particle Size
Average Pressure Drop Through Clean Filter • Buna-N Gasket standard. Fluorocarbon Gasket optional, consult factory.
Assembly With 150 SUS Oil At 105° F. • Caution: Do not use AE Series filter elements on internal combustion
engines.
ALLOW .63 INCH CLEARANCE • Aqua-Zorb filter medias absorb and retain free water. Any absorbed
FOR ELEMENT REMOVAL
3.7” DIA.
water cannot be liberated from the Aqua-Zorb media. As the element
(BOTH ELEMENT SIZES)
AE & ZAE Element Data: See Pages
becomes saturated with water, the Aqua-Zorb media continues to swell,
6&7 and will ultimately curtail flow through the filter. Not for use with
Commonly Ordered Configurations water-glycols. Zinga ProTect Shroud
ZAF10000 Harsh Environment Protection
FG03Q combines filter gasket
ZAF102513 with a protective shroud top.
ZAF13000 (Please Order Separately)

ZAF132513

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
7 8

ZAE SERIES VAF SERIES


SPIN-ONS

SPIN-ONS
Z-GLASS MEDIA SPIN-ON FILTER HEADS
SPIN-ON FILTER ELEMENTS
FOR USE WITH ZAF SERIES FILTER HEADS VE-10 SERIES
SPIN-ON FILTER ELEMENTS
Diameter: 3.8” VAF Heads:
Mounting Thread: 1” - 12 UN Flows Up To: 32 GPM (Return) 14 GPM (Suction)
Pressure: 250 PSI Max. Operating Port Size: 1" NPTF
∆Pmax: 80 PSID Pressure: 250 PSI Max. Operating
Temperature: Up to +250°F Operating Temperature: Up to +250°F Operating
Applications: Petroleum-based fluids. Applications: Petroleum-based fluids.
Consult factory for synthetic fluids.

VE-10:
Part Particle Nominal Absolute Can Color / Overall Mounting Thread: 1 1/8” - 16
Number Size Rating Rating Imprint Height ∆Pmax: 50 PSID
ZAE03 3 Micron ß<4µ(c) = 2 ß5µ(c) = 75 ß6µ(c) = 200 White / Green 5.8” Efficiency: ß<4µ(c) = 2 / ß19µ(c) = 75
ZAE10 10 Micron ß<4µ(c) = 2 ß10µ(c) = 75 ß14µ(c) = 200 White / Red 5.8” Can Color / Imprint: White / Red
Seals: Buna-N Gasket Standard
ZAE10L 10 Micron ß6µ(c) = 2 ß11µ(c) = 75 ß15µ(c) = 200 White / Red 8.5” Caution: Do not use VE Elements on
internal combustion engines.

VE Elements

Application Data:
• Reference: Cellulose Media
ßXµ(c) = 2 represents 50% efficiency at Particle Size
ßXµ(c) = 75 represents 98.7% efficiency at Particle Size
ßXµ(c) = 200 represents 99.5% efficiency at Particle Size
• Z-Glass Media Average Pressure Drop Through Clean Filter Assembly
• Buna-N gasket standard. Fluorocarbon gasket optional, consult With 150 SUS Oil At 105° F.
factory.
• Caution: Do not use ZAE Series filter elements on internal
combustion engines.

Zinga ProTect Shroud


Harsh Environment Protection
FG03Q combines filter gasket
with a protective shroud top.
(Please Order Separately)

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
9 10

SF100 SERIES SF120 SERIES


SPIN-ONS

SPIN-ONS
SPIN-ON FILTER HEADS SPIN-ON FILTER HEADS

Flows Up To: 40 GPM (Return) 15 GPM (Suction) Flows


25 Up To: 70 GPM (Return) 25 GPM (Suction)
Port Sizes: 1” NPTF; 1 5/16”-12 UN (SAE-16) Port Sizes: 1 1/4” NPTF; 1 5/8”-12 UN (SAE-20)
Pressure: 200 PSI Max. Operating 20 Pressure: 200 PSI Max. Operating

Pressure Drop (PSI)


Temperature: Up to +250°F Operating Temperature: Up toLE-10AZ
+250°F Operating
Applications: Petroleum-based fluids. Applications: Petroleum-based fluids. LE-25
15
Consult factory for synthetic fluids. Consult
SE-10factory for synthetic
SE-25 fluids.
LE-03AZ LE-10
10
25 LE-03

25 LE-10AZ 25 SE-03 LE-100


5 Cellulose Media
20 Cellulose Media (2) M10 x 1.5 x 20 mm DP
SE-03
LE-10AZ with BSP Ports
SE-100

(PSI)(PSI)
20 20
SE-03 0

Pressure Drop (PSI)


15 LE-10AZ
0

DropDrop
LE-03AZ 10 20 30 40 50 60 70 80
SE-10 LE-10 LE-25
15 15 Flow Rate (GPM)
LE-03AZ SE-25

Pressure
10 SE-10 LE-10 SE-10
1 1/4” NPTF OR 1 5/8”-12 UN (SAE-20)
LE-03 LE-03AZ LE-10

Pressure
10 LE-25 10
5 LE-03 LE-03
LE-100 SE-100
LE-25
5 SE-25 SE-03 LE-100
SE-100 5
0 LE-100
0 10 20 SE-2530 40 50 SE-100
0
0 10 Flow20Rate (GPM)
30 40 50 0
0 10 20 30 40 50 60 70 80
Flow Rate (GPM) Flow Rate (GPM)
50 50

50 Z-Glass Media Z-Glass Media


40 40

Pressure Drop (PSI)


SE Elements
(PSI)(PSI)

40
ZSE Elements
30 30
DropDrop

ZLE-10
1 1/2"-16 THD. 30 ZSE-10 ZSE-10
20
Pressure

ZSE-10 20 ZLE-03
20
Pressure

ZLE-03 ZSE-03
10 50
LE Elements ZSE-03 ZLE-03 10
ZLE Elements ZLE-25
10 ZLE-25
ZSE-03 ZLE-10
0 40
40 ZLE-25 50 0

Pressure Drop (PSI)


0 10 20 ZLE-10 30
0 0 10 20 30 40 50 60 70 80
0 10 Flow
20 Rate (GPM)
30 40 50 Flow Rate (GPM)
30
ZLE-10
Average PressureFlow Rate
Drop (GPM) Clean Filter
Through Average Pressure Drop Through Clean Filter
ZSE-10
Assembly With 150 SUS Oil At 105° F. 20 Assembly With 150 SUS
ZLE-03
Oil At 105° F.
ZSE-03

Commonly Ordered Configurations SE, LE, ZSE, & ZLE Element Data: See Commonly Ordered Configurations SE, 10
LE, ZSE, & ZLE Element Data: See
ZLE-25
SF100000 Pages 20 & 21 SF120000 Pages 20 & 21
0
SF130000 SF160000 0 10 20 30 40 50 60 70 80
SF1002513 SF1202513 Flow Rate (GPM)

SF1302513 SF1602513

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
11 12

SF122 SERIES SF150 SERIES


SPIN-ONS

SPIN-ONS
SPIN-ON FILTER HEADS SPIN-ON FILTER HEADS
WITH ∆P INDICATOR OPTION
25 Flows
Up To: 70 GPM (Return) 25 GPM (Suction) Flows Up To: 80 GPM (Return) 32 GPM (Suction)
Port Sizes: 1 5/8”-12 UN (SAE-20) Port Sizes: 1 1/2” NPTF
Pressure: 200 PSI Max. Operating Pressure: 200 PSI Max. Operating
20
Temperature: UpLE-10AZ
to +200°F Temperature: Up to +200° F Operating

Pressure Drop (PSI)


Applications: Petroleum-based fluids.LE-25 Applications: Petroleum-based fluids.

15 Consult
SE-10
factory for synthetic fluids.
SE-25 Consult factory for synthetic fluids.
Features: Socket design in
LE-10some models
LE-03AZ
10 allows machining for custom stems
LE-03
25
3 DP INDICATOR 25 SE-03 LE-100
3
(2) 5/16"-18 UN THREAD 5 Cellulose Media Cellulose Media
MTG. HOLES X 9/16" DEEP
2 SE-100 20
6
INLET & OUTLET PORT SIZES: 20 LE-10AZ LE-25

Pressure Drop (PSI)


1 5/8”-12 UN(SAE-20) 0 LE-10AZ

Pressure Drop (PSI)


LE-03
0 10 20 30 40 50 60 70LE-25
80 LE-10 &
3.22" 15
SE-25
15 Flow Rate (GPM) LE-03AZ
5 SE-10 SE-25 SE-03
SE -10
4
LE-03AZ LE-10 10 SE-100
.74" 1 10
1/8" NPTF GAUGE PORT (OPTIONAL) LE-03
1 DP INDICATOR INLET PRESSURE LOCATIONS: 1 2 3 (RETURN LINE)
OUTLE T PRESSURE LOCATIONS: 4 5 6 (SUCTION LINE) SE-03 LE-100 5 LE-100
5.34" 5
3.00" 1.87"
.61"
SE-100
.96" 1.12" 0
1.71" 0
2.4" 0 20 40 60 80 100
0 10 20 30 40 50 60 70 80
Flow Rate (GPM)
Flow Rate (GPM)
50 25
9.3"
1 1/2"-16 THREAD
SE ELEMENTS
Z-Glass Media
ZSE-10
ZSE ELEMENTS 20
40
Pressure Drop (PSI)

13.3"
ZLE-25

Pressure Drop (PSI)


ZLE-03
1 1/2"-16 THD.
SE ELEMENTS
30 15
ZLE-10
ZSE ELEMENTS ZSE-03
ZSE-10
20 ZLE-03 10
LE ELEMENTS ZLE-10
ZLE ELEMENTS ZSE-03
50 5
10
ALLOW 1.5" CLEARANCE
FOR ELEMENT REMOVAL
5.1" DIA. ZLE-25 Z-Glass Media
40 0
Pressure Drop (PSI)

0
0 10 20 30 40 50 60 70 80 0 20 40 60 80 100 120
Flow Rate (GPM) Flow Rate (GPM)
30
ZLE-10
ZSE-10 Average Pressure Drop Through Clean Filter
SE, LE, ZSE, & ZLE Element Data: See Average Pressure Drop Through Clean Filter
20 Assembly With ZLE-03
150 SUS Oil At 105° F. Assembly With 150 SUS Oil At 105° F.
Pages 20 & 21 ZSE-03
10
ZLE-25
Commonly Ordered Configurations
0
Commonly Ordered Configurations SE, LE, ZSE, & ZLE Element Data: See
SF162XX* 0 10 20 30 40 50 60 70 80 Pages 20 & 21
SF150000
SF122XX* Flow Rate (GPM)
SF1502513

*Additional information required to place an order. Contact factory for assistance.

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
13 14
25

MF SERIES Average Pressure Drop Through Clean Filter Assembly


3-ELEMENT SPIN-ON
SPIN-ONS

SPIN-ONS
20
With 150 SUS
LE-03 Oil At 105° F.
& SE-10

MODULAR LINE TYPE FILTER HEAD ASSEMBLY

Pressure Drop (PSI)


25
15

SPIN-ON FILTER HEADS


LE-10AZ
Cellulose Media
20
10 SE-03 LE-03 & SE-10

WITH ∆P INDICATOR OPTION

Pressure Drop (PSI)


LE-03AZ
15
5
LE-10AZ
SE-100
Flows Up To: 120 GPM (Return) 50 GPM (Suction) SE-25
10 LE-10
Port Sizes: 1 1/2" NPTF w/ 2” 4-Bolt Flange 0
SE-03
120 150 180
1 7/8" - 12 UN (SAE - 24) 0
LE-03AZ
30 60 90
Flow Rate (GPM)
Pressure: 200 PSI Max. Operating 5
SE-100
Temperature: Up to +200° F Operating SE-25
LE-10
Applications: Petroleum-based fluids. 0
0 30 60 90 120 150 180
Features: Multiple modular heads bolted together.
Flow Rate (GPM)
Inlet flow is equally divided among all elements
25
(parallel flow) providing greater flow
Z-Glass Media
capacities and longer service life.
20

Pressure Drop (PSI)


25
15
4-ELEMENT SPIN-ON
20
10
ZSE-03 ZLE-03
ZSE-10
FILTER HEAD ASSEMBLY

Pressure Drop (PSI)


15
5
ZLE-25
ZSE-10
ZLE-10
10 ZSE-10
SEE DP SERIES FOR DETAILS 0 ZLE-03
ZSE-03
0 20 40 60 80 100 120
3.06" Flow Rate (GPM)
5
25
LE-03AZ ZLE-25

20
LE-03
NOTES:
0
ZSE-10 ZLE-10

SE-10
80 100 120
Pressure Drop (PSI)

0 20 40 60
15
SE-03 Flow data for a MF-Series 4-element
Flow Rate (GPM) filter head is
LE-10 identical to the 3-element filter above. MF-Series fil-
10 ter heads with 4 or more elements will not significant-
1 1/2"-16 THD.
LE-10AZ
LE-100
ly reduce pressure drop or allow greater flow through
SE Elements 5
ZSE Elements SE-100 the assembly. The MF Series will lengthen the time
LE-25
0
SE-25 periods between element servicing.
0 30 60 90 120 150 180
Flow Rate (GPM)
Multiple unit head assemblies may require additional
mounting support for your application.
LE Elements
ZLE Elements

SE, LE, ZSE, & ZLE Element Data: See Pages 20 & 21
25 25
LE-03AZ
LE-03
Z-Glass Media
20 20
SE-10
Pressure Drop (PSI)

SE-03
Pressure Drop (PSI)

15 15
LE-10
ZLE-03
ZSE-03
10
10
LE-100
LE-10AZ
ZSE-10
5
SE-100 5
LE-25 ZLE-25
0
SE-25 Cellulose Media
ZLE-10
0 30 60 90 120 150 180 0
Flow Rate (GPM) 0 20 40 60 80 100 120
Flow Rate (GPM)

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
15 16

ZDF SERIES Average Pressure Drop Through Clean Filter Assembly With 150 SUS Oil at 105° F. Temperature.
SPIN-ONS

SPIN-ONS
25 25

SIDE-BY-SIDE 20
Cellulose Media
LE-03AZ
LE-03
Z-Glass Media
SPIN-ON FILTER HEADS SE-10 20

Pressure Drop (PSI)


SE-03

Pressure Drop (PSI)


15
WITH ∆P INDICATOR OPTION LE-10
15

ZLE-03
10 ZSE-03
10
LE-100
LE-10AZ
Flows Up To: 120 GPM (Return) 50 GPM (Suction) 5 ZSE-10
SE-100
Port Sizes: 1 1/2" NPTF w/ 2" 4-Bolt Flange LE-25
5
ZLE-25
SE-25
1 7/8" - 12 UN (SAE - 24) 0 ZLE-10
120 150 180
Pressure: 200 PSI Max. Operating 0 30 60 90
Flow Rate (GPM)
0
0 20 40 60 80 100 120
Temperature: Up to +200° F Operating Flow Rate (GPM)
Applications: Petroleum-based fluids.
Consult factory for synthetic fluids.
ZDF, MF, & MFT parallel flow modular components can be combined into filter head assemblies such as
these. Other combinations are available to meet specific filter applications. For technical advice
contact your local distributor or the factory. NOTE: Some multiple-head units may require additional
mounting support.
25

20

Pressure Drop (PSI)


SEE DP SERIES FOR DETAILS 15

ZLE-03
ZSE-03
10

ZSE-10
5
ZLE-25
ZLE-10
0
0 20 40 60 80 100 120
Flow Rate (GPM)

SE, LE, ZSE, & ZLE Element Data: See Pages 20 & 21

1 1/2"-
16 THD.
SE Elements
ZSE Elements

LE Elements
ZLE Elements

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
SERIES ME-L DIFFERENTIAL
& 1.88"
Shown with Zinga DP06 Series DC
ZME-L PRESSURE Electrical Indicator
INDICATOR PORT
SERIES
17 4.00"
Shown with Zinga DP06 Series DC 18
ø 3.70" Electrical Indicator

ALLOW 1" 1.34"

DHF SERIES
FOR ELEMENT 2.47" 1.88" 1 3 / 8"-12 THD. TYP. ø253.70" 1.95" 12.5
6.0" TYP ME & ZME
SPIN-ONS

SPIN-ONS
REMOVAL SERIES
9.5" TYP ALLOW 1"
SPIN-ON FILTER HEADS FOR ELEMENT
REMOVAL
20 10 ZME-22

PRESSURE DROP (PSI)


Pressure Drop (PSI)
ZME-05L
WITH ∆P INDICATOR OPTION 15
ME-10
7.5
ME-L
1 3& / 8"-12 THD. TYP.
ZME-16

6.0" TYP ME & ZME ZME-L ME- 0 3 ZME-05 ZME-22 L

Flows Up To: 35 GPM SERIES SERIES 10 5


9.5" TYP Shown
ZME-16 L with Zinga DP06 Series DC
Port Sizes: 3/4” NPTF; 1” NPTF ME-10 L
Electrical Indicator
1 1/16”-12UN (SAE-12); 1 5/16”-12UN (SAE-16) 5
ME- 0 3 L
2.5
Pressure: 500 PSI Maximum Operating ø 3.70" Cellulose Media Z-Glass Media
ME-L &
1000 PSI Static Burst Top Right Indicator
ALLOW 1"
ZME-L Right Side 0
Left Side 0
Temperature: Up to +200°F FOR ELEMENT
SERIES 0 Shown
5 with Side
10 Indicator
15 Port 20 25 30 35 0 5 10 15 20 25 30 35
1.38" and DP06 Series Single Wire
FlowDCRate
Indicator
(GPM)
Filters: ME & ZME Series REMOVAL
3/8"-16 UNC-2B
FLOW RATEShown
(GPM) with Zinga DP06 Series DC
Electrical Indicator
Shown with Side Indicator Port
Average Pressure Drop Through Clean
and DP06 Series SingleFilter
Wire DCAssembly
Indicator
Assembly Fatigue Strength: 100,000 cycles @ 0-500 PSI
1.38" ø 3.70" With 150 SUS Oil At 105°F
300,000 cycles @ 0-400 PSI
1.27" ALLOWPSI
1"
1,000,000 cycles @ 0-350
FOR ELEMENT
REMOVAL DIFFERENTIAL
Applications: Petroleum-based fluids. PRESSURE
Consult factory for synthetic fluids. INDICATOR PORT
4.00"

Top Right Indicator Right Side 1.34" Left Side Shown with Zinga DP04 Series
2.47" 1.88"
Visual Indicator 1.95" Shown with Side Indicator Port
1.38" Shown with Zinga DP05 Series
and DP06 Series Single Wire DC Indicator
3/8"-16 UNC-2B Shown with Zinga DP04 Series Visual/Electrical Indicator
Visual Indicator
DHF Series Filter Head Shown Shown with Zinga DP05 Series
Without Indicator Visual/Electrical Indicator
1.38"
1.27" DHF Series Filter Head Shown
Without Indicator
1 3 / 8"-12 THD. TYP. Shown with Side Indicator Port
6.0" TYP ME & ZME and DP06 Series Single Wire DC Indicator
DIFFERENTIAL SERIES
PRESSURE 9.5" TYP
4.00" INDICATOR PORT

1.34" ME-L &


ZME-L Shown with Zinga DP04 Series
2.47" 1.88" 1.95" Visual Indicator
SERIES Shown with Zinga DP05 Series
Shown with Zinga DP06 Series DC
Visual/Electrical Indicator
Electrical Indicator
DHF Series Filter Head Shown
Without Indicator
ø 3.70"
ALLOW 1" Shown with Zinga DP04 Series
1 3 / 8"-12 THD. TYP. Visual Indicator ZME Element Data: See Page 24
6.0" TYP ME & ZME FOR ELEMENT Shown with Zinga DP05 Series
SERIES REMOVAL Visual/Electrical Indicator
9.5" TYP
DHF Series Filter Head Shown
Without Indicator

ME-L &
ZME-L
SERIES
Shown with Zinga DP06 Series DC
Electrical Indicator

ø 3.70"
ALLOW 1"
FOR ELEMENT Shown with Side Indicator Port
REMOVAL and DP06 Series Single Wire DC Indicator

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
19 20

DF15 SERIES SE & LE SERIES


SPIN-ONS

SPIN-ONS
OVER / UNDER SPIN-ON FILTER ELEMENTS
SPIN-ON FILTER HEADS FOR USE WITH SF, DF, MF, MFT & ZDF
WITH ∆P INDICATOR OPTION SERIES FILTER HEADS

Flows Up To: 120 GPM (Return) 50 GPM (Suction) Diameter: 5.1”


Port Sizes: 1 1/2" NPTF w/ 2” 4-Bolt Flange Mounting Thread: 1-1/2”-16 UN
Pressure: 200 PSI Max. Operating Pressure: 200 PSI Max. Operating
Gauge not included – must be ordered separately. Temperature: Up to +200°F Operating ∆Pmax: 50 PSID
Limited by Indicator Selection Temperature: Up to +250°F Operating
Applications: Petroleum-based fluids. Applications: Petroleum-based fluids.
Consult factory for synthetic fluids.

25
P INDICATOR OPTION
Part Particle Nominal Absolute Can Color / Media Free Water Overall
(SEE DP SERIES FOR DETAILS) Cellulose Media Number Size Rating Rating Imprint Type Absorption Height
3.25" 20
1 2 1/8" NPTF GAUGE PORTS STANDARD
LE-10AZ SE03 3 Micron ß<4µ(c) = 2 ß11µ(c) = 75 White / Green Cellulose 6.9”
INLET PRESSURE LOCATION: 1 LE-10
Pressure Drop (PSI)
LE-25
(RETURN LINE) SE10 10 Micron ß5µ(c) = 2 ß19µ(c) = 75 White / Red Cellulose 6.9”
15 SE-10
2 SE-25
2.68" OUTLET PRESSURE LOCATION:
LE-03AZ
SE100 141 Micron - - White / Blue Stn. Steel Mesh 6.9”
(SUCTION LINE)
LE-3
10 SE25 25 Micron ß19µ(c) = 2 ß36µ(c) = 75 White / Black Cellulose 6.9”
SE-3
2.90" LE03 3 Micron ß<4µ(c) = 2 ß11µ(c) = 75 White / Green Cellulose 10.9”
LE-100
5 SE-100 LE03AZ 3 Micron ß<4µ(c) = 2 ß11µ(c) = 75 White / Orange Aqua-Zorb 15 oz. 10.9”
5.3"
2.56" LE10 10 Micron ß5µ(c) = 2 ß19µ(c) = 75 White / Red Cellulose 10.9”
4.03"
6.5" 0
3.06" 0 40 80 120 160 LE100 141 Micron - - White / Blue Stn. Steel Mesh 10.9”
(2) 3/8"-16UNC-2B
x 9/16" DEEP Flow Rate (GPM)
MTG. HOLES
LE10AZ 10 Micron ß5µ(c) = 2 ß19µ(c) = 75 White / Orange Aqua-Zorb 15 oz. 10.9”
1.4" 25 LE25 25 Micron ß19µ(c) = 2 ß19µ(c) = 75 White / Black Cellulose 10.9”
1.69" 2.8"
Z-Glass Media
20
Pressure Drop (PSI)

ZLE-10
1 1/2"-16 THREAD Application Data:
15 ZSE-10
8.5" • Reference:
SE ELEMENTS
ZLE-03 ßXµ(c) = 2 represents 50% efficiency at Particle Size
ZSE ELEMENTS 12.5" 10 ßXµ(c) = 75 represents 98.7% efficiency at Particle Size
ZSE-03
ZLE-25 • Buna-N FG01 gasket standard. Fluorocarbon gasket FG01V optional, consult factory.
5 • Caution: Do not use SE/LE Series filter elements on internal combustion engines.
• Aqua-Zorb filter medias absorb and retain free water. Any absorbed water cannot be liberated from the
LE ELEMENTS
ZLE ELEMENTS
0 Aqua-Zorb media. As the element becomes saturated with water, the Aqua-Zorb media continues to
0 20 40 60 80 100 120 swell, and will ultimately curtail flow through the filter. Not for use with water-glycols.
Flow Rate (GPM)
ALLOW 1.5" CLEARANCE
5.1" FOR ELEMENT REMOVAL
Average Pressure Drop Through Clean Filter
Assembly With 150 SUS Oil At 105° F.

SE, LE, ZSE, & ZLE Element Data: See


Pages 20 & 21

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
21 22

ZSE & ZLE SERIES HF SERIES


SPIN-ONS

SPIN-ONS
Z-GLASS MEDIA SPIN-ON FILTER HEADS
SPIN-ON FILTER ELEMENTS WITH ∆P INDICATOR OPTION
FOR USE WITH SF, DF, MF, MFT & ZDF
SERIES FILTER HEADS

Diameter: 5.1” Flows Up To: 40 GPM (Return)


Mounting Thread: 1-1/2”-16 UN Port Sizes: 3/4" NPTF; 1” NPTF
Pressure: 200 PSI Max. Operating 3/4" BSP; 1" BSP
∆Pmax: 80 PSID 1 1/16"-12UN (SAE-12); 1 5/16"-12UN (SAE-16)
Temperature: Up to +250°F Operating Pressure: 400 PSI Max. Operating
Applications: Petroleum-based fluids. Temperature: Up to +200° F w/indicator
Application: Petroleum-based fluids only.
Consult factory for synthetic fluids.

Part Particle Nominal Absolute Can Color / Overall


25
Number Size Rating Rating Imprint Height
2.12”

OUTLET

INLET
ZSE03 3 Micron ß<4µ(c) = 2 ß<4µ(c) = 75 ß<7µ(c) = 1000 White / Green 6.9” FLOW
3.52”
1.23” DIA. 20 HE-03AZL
ZSE10 10 Micron ß<4c) = 2 ß8µ(c) = 75 ß12µ(c) = 1000 White / Red 6.9”

Pressure Drop (PSI)


ZLE03 3 Micron ß<4c) = 2 ß<4µ(c) = 75 ß<7µ(c) = 1000 White / Green 10.9”
15
ZLE10 10 Micron ß<4(c) = 2 ß8µ(c) = 75 ß12µ(c) = 1000 White / Red 10.9” 2.00”
OPTIONAL ∆P INDICATOR
(3) 5/16”-18 UNC-2B THD. D.C. OR VISUAL MODELS
HE-03
MTG. HOLES X .50”DP.
M10 X 1.5 X 14 mm WITH BSP PORTS
SEE DP SERIES FOR DETAILS 10 HE-10
4.14”

5
1.00”
HE-10L
1.94” Cellulose Media
0
0 10 20 30 40
Flow Rate (GPM)
Application Data: 7.90”
• Reference: 1 1/2”-16 THD.
HE Elements Average Pressure Drop Through Clean Filter
ßXµ(c) = 2 represents 50% efficiency at Particle Size 10.03” Assembly With 150 SUS Oil At 105° F.
ßXµ(c) = 75 represents 98.7% efficiency at Particle Size
ßXµ(c) = 1000 represents 99.5% efficiency at Particle Size
• Buna-N FG01 gasket standard. Fluorocarbon gasket FG01V optional, consult factory.
• C
 aution: Do not use ZSE/ZLE Series filter elements on internal combustion engines.
HE-L Elements

HE Element Data: See Page 23


ALLOW 1.5" FOR
3.67” DIA. ELEMENT REMOVAL

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
23 24

HE SERIES ZME SERIES


SPIN-ONS

SPIN-ONS
MEDIUM PRESSURE MEDIUM PRESSURE
SPIN-ON FILTER ELEMENTS SPIN-ON FILTER ELEMENTS
FOR USE WITH HF SERIES FILTER HEADS. FOR USE WITH DHF SERIES FILTER HEADS.

Diameter: 3.7” Diameter: 3.7”


Mounting Thread: 1-1/2” - 16 UN Mounting Thread: 1-3/8”-12 UN
Pressure: 400 PSI Max. Operating Pressure: 500 PSI Max. Operating
∆Pmax Cellulose: 50 PSID ∆Pmax Cellulose: 80 PSID
∆Pmax Z-Glass: 80 PSID ∆Pmax Z-Glass: 100 PSID
Temperature: Up to +250°F Operating Temperature: Up to +250°F Operating
Applications: Petroleum-based fluids. Applications: Petroleum-based fluids.

Part Particle Nominal Absolute Can Color / Media Free Water Overall Part Particle Nominal Absolute Can Color / Media Overall
Number Size Rating Rating Imprint Type* Absorption Height Number Size Rating Rating Imprint Type Height
HE03 3 Micron ß<4µ(c) = 2 ß7µ(c) = 75 White / Green Cellulose 5.9” ZME05 5 Micron ß<4µ(c) = 2 ß<4µ(c) = 75 ß5µ(c) = 200 White / Green Z-Glass 6.0”

HE03AZL 3 Micron ß5µ(c) = 2 ß24µ(c) = 75 White / Orange Aqua-Zorb 7.2 oz 8.0” ZME16 16 Micron ß<4µ(c) = 2 ß10µ(c) = 75 ß14µ(c) = 200 White / Red Z-Glass 6.0”

HE10 10 Micron ß11µ(c) = 2 ß25µ(c) = 75 White / Red Cellulose 5.9” ZME16L 16 Micron ß<4µ(c) = 2 ß10µ(c) = 75 ß14µ(c) = 200 White / Red Z-Glass 9.5”

HE10L 10 Micron ß<4µ(c) = 2 ß19µ(c) = 75 White / Red Cellulose 8.0”

*Glass media is available. Contact factory for quote.

Application Data: Application Data:


• Reference: • Reference:
ßXµ(c) = 2 represents 50% efficiency at Particle Size ßXµ(c) = 2 represents 50% efficiency at Particle Size
ßXµ(c) = 75 represents 98.7% efficiency at Particle Size ßXµ(c) = 75 represents 98.7% efficiency at Particle Size
• Buna-N gasket standard. Fluorocarbon gasket optional, consult factory. ßXµ(c) = 200 represents 99.5% efficiency at Particle Size
• Suitable for petroleum-based fluids. Consult factory for synthetic fluids. • Application: Petroleum-based fluids. Consult factory for synthetic fluids
• Caution: Do not use HE Series filter elements on internal combustion engines. • Caution: Do not use ZME Series filter elements on internal combustion engines.
• A qua-Zorb filter medias absorb and retain free water. Any absorbed water cannot be liberated from the
Aqua-Zorb media. As the element becomes saturated with water, the Aqua-Zorb media continues to swell,
and will ultimately curtail flow through the filter. Not for use with water-glycols.

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
25 26

C16 SERIES CF / CE SERIES


CARTRIDGE FILTER MANIFOLD CARTRIDGE FILTERS
Flows Up to: 12 GPM Operating Pressure: 6,000 PSI
Cavity: Common Cavity No. C16-2 Flows Up To: 30 GPM
Media: 10-Micron Stainless Steel Mesh
PRESSURE

PRESSURE
Pressure: 3,000 PSI Max.
Temperature: Up to +250°F Operating Applications: Petroleum-based fluids
Applications: Petroleum-based fluids

1.5" HEX

CE- 04-10

.50"

CE-04-75 & CE- 04-141

2.30"
50

40

Pressure Drop (PSI)


30

Flow 20
CE-12-10
Average Pressure Drop Through Clean Filter Assembly
1.12" DIA.
With 150 SUS At 105° F 10
CE-12-75 & CE-12-141
Sized to fit Common Cavity No. C16-2 0
0 5 10 15 20
Flow Rate (GPM)
50

40

Application Data:

Pressure Drop (PSI)


30
• Steel construction with stainless steel mesh media
CE-30-10
• C16-Series filters are designed to be used as final filters to protect control valves, not as system filters.
20

10

CE-30-75 & CE-30-141


0
0 10 20 30 40
Flow Rate (GPM)

Avg. pressure drop with 150 SUS oil at 105˚ F.

A B C D E F G H J
B/P Valve Element Flow Hex Hex Element Element SAE Cavity Max. Max. Port Max.
Assy Number Capacity Size Height Length Dia. Port Depth Min. Dia. Min.

CF04 CE0410 4 GPM 1.00” .41” 1.72” .74” -10 (7/8”-14) 1.12”
2.41” 2.66” .781”
1.87” .814”
1.49” 1.140”
CF12 CE1210 12 GPM 1.50” .50” 2.50” 1.00” -16 (1 5/16”-12) 3.34” .531”
2.53 1.187”
1.92” 1.750”
CF30 CE3010 30 GPM 2.13” .65” 4.00” 1.50” -24 (1 7/8”-12) 5.01”
3.81” .875” 1.803”
CF/CE Series filters are used as final filters to protect control valves, not as system filters.
Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
27 28

CF-90 SERIES G SERIES ELEMENTS


IN-LINE PALL 9020/9021 INTERCHANGE
HIGH-PRESSURE FILTER
Port Size: 1/2" NPTF Media: Zinga Synthetic Z-Glass Media
PRESSURE

PRESSURE
3/4" - 16 UN (SAE-8) Application: P3000 Series Pressure Filters
Pressure: 3,000 PSI Temperature: Nitrile Seals -45°F to +225°F
Flows Up To: 12 GPM Fluorocarbon Seals -20°F to +275°F
By-Pass Valve Setting: 50 PSI
Filtration: 10-Micron Stainless Steel
Wire Cloth Standard
150 PSID RATED ELEMENTS
(For Use in Filters with By-pass Valve Only)
ZINGA P/N BXμ(c) = 200 BXμ(c) = 1000 PALL P/N
G0403LN <4 Micron <4 Micron HC9024FDP4H
50 G0406LN 5 Micron 6 Micron HC9024FDN4H
G0410LN 8 Micron 10 Micron HC9024FDS4H
40 G0420LN 19 Micron 23 Micron HC9024FDT4H
G0803LN <4 Micron <4 Micron HC9024FDP8H

Pressure Drop (PSI)


30 G0806LN 5 Micron 6 Micron HC9024FDN8H
G0810LN 8 Micron 10 Micron HC9024FDS8H
20 G0820LN 19 Micron 23 Micron HC9024FDT4H
CE-12-10
Buna-N Seals Standard. Replace “N” in P/N with “V” for Fluorocarbon.
10
CE-12-75 & CE-12-141
3000 PSID RATED ELEMENTS
0 ZINGA P/N BXμ(c) = 200 BXμ(c) = 1000 PALL P/N
0 5 10 15 20
Flow Rate (GPM) G0403HN <4 Micron <4 Micron HC9021FUP4H
G0410HN 8 Micron 10 Micron HC9021FUS4H
Avg. pressure drop with 150 SUS oil at 105˚ F.
G0803HN <4 Micron <4 Micron HC9021FUP8H
G0810HN 8 Micron 10 Micron HC9021FUS8H
Buna-N Seals Standard. Replace “N” in P/N with “V” for Fluorocarbon.

Average Pressure Drop Through Clean Element


With 150 SUS Oil At 100˚ F (32 cSt at 40° C)
Note:
• CE-Series
 filter elements are compatible with petroleumbase fluids, water glycol, diesel fuel, & gaso-
line (except if containing alcohol). For fluids not listed, consult factory.
• Element access plug uses a Buna-N O-ring as standard (for use with petroleum-base fluids).
Fluorocarbon O-ring optional (for use with synthetic fluids).

G04 Series G08 Series

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
29 30

HP3000 SERIES Average pressure drop through clean filter with 150 SUS oil at 105˚ F.

IN-LINE PRESSURE FILTERS


50
WITH ∆P INDICATOR OPTION 45
ZHP2603

PRESSURE DIFFERENTIAL (PSID)


HP2603
40
Flows Up To: 60 GPM
PRESSURE

PRESSURE
35
Ports Sizes: 1” NPTF ZHP2610
30
1 1/16”-12 UN (SAE - 12) HPM2610
1 5/16”-12 UN (SAE - 16) 25 HP2610

Pressure: 3,000 PSI Max. Operating 20 HP2625


HP26141
Application: Inline Filtration, 15
90° Design Permits Element 10
Replacement without Breaking Line. 5
HP2675 HP2603
HP26560
2.88" HP26238
0
SPECIFICATIONS 0 5 10 15 20 25 30 35
FLOW RATE (GPM)
40 45 50 55 60

Code Removal Rating


Number
03Z (Z-Glass) B<4μ(c) = 200 B7μ(c) = 1000
10Z (Z-Glass) B10μ(c) = 200 B12μ(c) = 1000 3.0" DIA.
003 (Cellulose) B<4μ(c) = 2
ACCESSORIES:
3.56" 010 (Cellulose) B5μ(c) = 2 1.92"
025 (Cellulose) B19μ(c) = 2
2.00" INLET
REFERENCE
Bxµ(c) Rating of 1000 = 99.9% Efficiency 2.28"
Bxµ(c) Rating of 200 = 99.5% Efficiency
Bxµ(c) Rating of 2 = 50.0% Efficiency 3/8" HARDWARE
2.56" SUPPLIED
PRESSURE RATING 4.33"
Maximum Operating: 3,000 PSI (207 Bar)
Burst Pressure: 15,000 PSI (1034 Bar) .81"
Rated Fatigue Pressure:
OUTLET HP26 SERIES ELEMENT 0-3000-0 PSI for 1,000,000 Cycles
UB-300 U-BOLT CLAMP
(FOR USE WITH HP3000 SERIES FILTER)
TEMPERATURE RANGE
9.7" Operating: -40°F to +250°F
(-40°C to +120°C)

BY-PASS SETTING:
50 PSID

∆P INDICATOR OPTIONS
ELEMENT ACCESS CAP Visual, Single-Wire DC Electrical, or
BY-PASS VALVE ASSEMBLY Electrical/Visual w/ DIN Connector
(50 PSID SET POINT)
FLUID COMPATIBILITY
Elements: Suitable For Use with
Petroleum-Base Fluids. Consult
Factory For Use With Other Fluids.

MATERIALS
Housing: Ductile Iron
By-Pass: Steel
INDICATOR OPTIONS: Element Hardware: Plated Carbon
Steel Endcaps and Core.
DP04 SERIES VISUAL (SHOWN)
Epoxy Endcap Adhesive.
DP05 SERIES VIS/ELE W/DIN Filter Media: Z-Glass Fiber, Cellulose
DP06 SERIES DC SINGLE WIRE Stainless Steel Mesh
WEIGHT
4.2 lbs. (2.2 Kg)

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
31 32

P3000 SERIES P3000 PRESSURE DROP CURVES


PRESSURE FILTERS Fluid Viscosity 150 SUS at 105°F (33 CS at 41°C)

WITH ∆P INDICATOR OPTION


4” Length 8” Length
Flows Up To: 30 GPM (114 L/MIN)
PRESSURE

PRESSURE
50 50
Ports Size: 1 1/16”-12 UN (SAE - 12)
Pressure: 3,000 PSI (207 BAR) 45 45
G0403L
Application: Inline Filtration,
40 40
External Charge Pump Filtration, G0410H

Pressure Drop (PSID)


High-Shock Return Line Filtration 35 35

Pressure Drop (PSID)


G0403H
30 30
G0803L
25 25
G0810H
4.00 INDICATOR SPECIFICATIONS 20 20
5/16"-18UN x 5/8" POSITION #1 Code Removal Rating
Number G0803H
DEEP MTG. HOLES 15 15
03H (Z-Glass) ß<4μ(c) = 200 ß<4μ(c) = 1000
03L (Z-Glass) ß<4μ(c) = 200 ß<4μ(c) = 1000 10 G0420L 10 G0820L
1.75
06L (Z-Glass) ß5μ(c) = 200 ß6μ(c) = 1000 G0810L
G0410L
1.19 10L (Z-Glass) ß8μ(c) = 200 ß10μ(c) = 1000 5 5 G0806L
10H (Z-Glass) ß8μ(c) = 200 ß10μ(c) = 1000 G0406L
20L (Z-Glass) ß19μ(c) = 200 ß23μ(c) = 1000 0 0
INDICATOR 0 5 10 15 20 25 30 0 5 10 15 20 25 30
10C (cellulose) ß5μ(c) = 2
3.00 POSITION #2 Flow Rate (GPM) Flow Rate (GPM)
REFERENCE
ßXμ(c) Rating of 1000 = 99.9% Efficiency
ßXμ(c) Rating of 200 = 99.5% Efficiency
1.23 ßXμ(c) Rating of 2 = 50.0% Efficiency
3.28 PRESSURE RATING
Maximum Operating: 3,000 PSI (207 Bar)
Burst Pressure: 8,600 PSI (580 Bar)
Rated Fatigue Pressure:
0-3000-0 PSI for 1,000,000 Cycles

TEMPERATURE RANGE
Operating: -40°F to +250°F
(-40°C to +120°C)

P3000G04=6.5"
BY-PASS SETTING OPTION:
No By-Pass or 50 PSID
P3000G08=10.3" P3000G04=4.0"
P3000G08=7.8" ∆P INDICATOR OPTIONS
Visual, Single-Wire DC Electrical, or
Electrical/Visual w/ DIN Connector

FLUID COMPATIBILITY
Elements: Suitable For Use with
Petroleum-Base Fluids. Consult
Factory For Use With Other Fluids.

MATERIALS
Head: Die-Cast Aluminum
Bowl: Anodized Aluminum (6061-T6)
By-Pass: Nylon
Element Hardware: Plated Carbon
Steel Endcaps and Core. Epoxy
Endcap Adhesive.
O 2.64 Filter Media: Z-Glass Fiber Standard
Allow 1.5" Clearance
for Bowl Removal
WEIGHT
P3000G04: 4.2 lbs. (2.2 Kg)
P3000G08: 5.2 lbs. (2.8 Kg)

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
33 34

W1200 SERIES W1200 PRESSURE DROP CURVES


PRESSURE FILTERS Fluid Viscosity 150 SUS at 105°F (33 CS at 41°C)

WITH ∆P INDICATOR OPTION


4” Length 8” Length
Flows Up To: 120 GPM (454 L/MIN)
PRESSURE

PRESSURE
50 50
Port Sizes: 1 1/4” & 1 1/2” NPTF
1 5/8”-12UN (SAE-20) 45 45
1 7/8”-12UN (SAE-24) W0403L
40 40
Max. Operating Pressure: 1,200 PSI (83 BAR)
Application: Inline Filtration 35 35

Pressure Drop (PSID)

Pressure Drop (PSID)


W0403H W0410H W0803H
High-Shock Return Line Filtration
30 30
W0803L
25 25
W0406L
5.00"
SPECIFICATIONS 20 20
Code Removal Rating W0810H
4.37"
Number 15 15
W0420L W0806L W0810L
03H (Z-Glass) ß<4μ(c) = 200 ß<4μ(c) = 1000 10 10
03L (Z-Glass) ß<4μ(c) = 200 ß<4μ(c) = 1000 W0410L W0820L
06L (Z-Glass) ß5μ(c) = 200 ß6μ(c) = 1000 5 5
10L (Z-Glass) ß8μ(c) = 200 ß10μ(c) = 1000
4.70" 2.44" 10H (Z-Glass) ß8μ(c) = 200 ß10μ(c) = 1000 0 0
1.80" 20L (Z-Glass) ß19μ(c) = 200 ß23μ(c) = 1000 0 20 40 60 80 100 120 0 20 40 60 80 100 120
Flow Rate (GPM) Flow Rate (GPM)
MOUNTING HOLES REFERENCE
5/16" -18 UN x .53 DP ßXμ(c) Rating of 1000 = 99.9% Efficiency
DP INDICATOR PORT ßXμ(c) Rating of 200 = 99.5% Efficiency
.
PRESSURE RATING
Maximum Operating: 1,200 PSI (83 Bar)
1.50" Burst Pressure: 3,000 PSI (206 Bar)
1.00"
Rated Fatigue Pressure:
0-1000-0 PSI for 1,000,000 Cycles
2.60" TEMPERATURE RANGE
Operating: -40°F to +250°F
(-4°C to +120°C)

BY-PASS SETTING OPTION:


No By-Pass or 50 PSID
W1200W04 = 7.5" ∆P INDICATOR OPTIONS
W1200W08 = 11.1" Visual, Single-Wire DC Electrical, or
W1200W04 = 4.9" Electrical/Visual w/ DIN Connector
W1200W08 = 8.5"
FLUID COMPATIBILITY
Elements: Suitable For Use with
Petroleum-Base Fluids. Consult
Factory For Use With Other Fluids.
KNURLED GRIP
SURFACE MATERIALS
Head: Die-Cast Aluminum
Bowl: Anodized Die-Cast Aluminum
By-Pass: Nylon
Element Hardware: Plated Carbon
Steel Endcaps and Core. Epoxy
Endcap Adhesive.
ALLOW 1.5" CLEARANCE
Filter Media: Z-Glass Fiber Standard
FOR BOWL REMOVAL WEIGHT
W1200W04: 6.6 lbs. (3 Kg)
W1200W08: 8.8 lbs. (4 Kg)

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
35 36

SLF1 SERIES SLE1 & ZSLE1 SERIES


TANK-TOP FILTERS FILTER ELEMENTS
(WITH INTEGRAL TANK BREATHER) CELLULOSE AND SYNTHETIC

Flows Up To: 25 GPM (Return)


Port Sizes: 1/2" & 3/4" NPTF, SAE & BSP
Pressure: 100 PSI Max. Operating Pressure
300 PSI Burst
Temperature: -15 to +230°F Operating
Head: Die-Cast Aluminum Alloy
TANK-TOP

TANK-TOP
Bowl / Cover: Nylon
Breather: 10-Micron (Foam) Standard SLE1 & ZSLE1 FILTER ELEMENTS 1.8"
Applications: Petroleum-based fluids only
Code Media Type Nominal Rating Absolute Rating
Consult factory for synthetic fluids
SLE103 Cellulose ß<4µ(c) = 2 ß11µ(c) = 75
SLE110 Cellulose ß5µ(c) = 2 ß19µ(c) = 75
1.88" 2.77"
MAX. SLE125 Cellulose ß19µ(c) = 2 ß36µ(c) = 75
35° 1/8" NPT GAUGE PORT INSTALLATION LAYOUT
PLUGGED (STD.) ZSLE103 Z-Glass ß<4µ(c) = 2 ß<4µ(c) = 200
3.46" / 3.34"
ZSLE110 Z-Glass ß<4µ(c) = 2 ß10µ(c) = 200 7.9"
3/8" BOLT HOLES
(2 PLACES)
3.46" 3.34" 1.66"

1/8" NPT GAUGE PORT


.44" PLUGGED (STD.) 2.5" / 2.4" DIA.
35°

Average pressure drop through clean assembly with 150 SUS oil at 105° F
2.75"

OPTIONAL DIPSTICK
10 MICRON
BREATHER
2.79"
Cellulose Media Z-Glass Media
25 25
INLET PORT
3/4" & 1"
1.19" NPTF, SAE, OR BSP 20 20

Pressure Drop (PSI)


Pressure Drop (PSI)
SLE103 ZSLE103 ZSLE110
.06" BUNA-N SLE110
GASKET 15 15
FILTER ELEMENT
BYPASS
(25 PSID STD.) 10 10

8.8" DIPSTICK 5 5
7.23" DEPTH
SLE125
0 0
0 5 10 15 20 25 0 5 10 15 20 25
FILTER ELEMENT:
3, 10, & 25 MICRON Flow Rate (GPM) Flow Rate (GPM)
NOMINAL (CELLULOSE)
3 & 10 MICRON
ABSOLUTE (SYNTHETIC)
.90"
HOSE BEAD
OUTLET

1.03"

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
37 38

SLF2 SERIES SLE2 & ZSLE2 SERIES


TANK-TOP FILTERS FILTER ELEMENTS
(WITH INTEGRAL TANK BREATHER) CELLULOSE AND SYNTHETIC

Flows Up To: 40 GPM (Return)


Port Sizes: 3/4" & 1" NPTF, SAE & BSP
Pressure: 100 PSI Max. Operating Pressure
300 PSI Burst
Temperature: -15 to +230°F Operating
Head: Die-Cast Aluminum Alloy
TANK-TOP

TANK-TOP
Bowl / Cover: Nylon
Breather: 10-Micron (Foam) Standard SLE2 & ZSLE2 FILTER ELEMENTS 2.5"
Applications: Petroleum-based fluids only Code Media Type Nominal Rating Absolute Rating
Consult factory for synthetic fluids SLE203 Cellulose ß<4µ(c) = 2 ß11µ(c) = 75
SLE210 Cellulose ß5µ(c) = 2 ß19µ(c) = 75
2.76" 3.22"
MAX. SLE225 Cellulose ß19µ(c) = 2 ß36µ(c) = 75
35° 1/8" NPT GAUGE PORT ZSLE203 Z-Glass ß<4µ(c) = 2 ß<4µ(c) = 200
PLUGGED (STD.)
ZSLE210 Z-Glass ß<4µ(c) = 2 ß10µ(c) = 200 11.7"

4.53" 4.33" 1.66"

1/8" NPT GAUGE PORT


.44" PLUGGED (STD.)

35°

Average pressure drop through clean assembly with 150 SUS oil at 105° F
3.95"

OPTIONAL DIPSTICK
10 MICRON
BREATHER
3.28"
Cellulose Media Z-Glass Media
25 25
INLET PORT
3/4" & 1"
1.24" NPTF, SAE, OR BSP 20 20

Pressure Drop (PSI)

Pressure Drop (PSI)


.06" BUNA-N ZSLE203
GASKET 15 15
FILTER ELEMENT ZSLE210
SLE210
BYPASS 10 10
(25 PSID STD.) SLE203
9.8" DIPSTICK 5 5
11.0" DEPTH
SLE225
0 0
0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40
FILTER ELEMENT:
3, 10, & 25 MICRON Flow Rate (GPM) Flow Rate (GPM)
NOMINAL (CELLULOSE)
3 & 10 MICRON
ABSOLUTE (SYNTHETIC)
.94"
HOSE BEAD
OUTLET

1.36"

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
39 40

TR & TS SERIES
Design Features:
• No parts to lose with unitized cover and by-pass valve assembly.
SUCTION / RETURN LINE



Radial seal grommets used in RE and SRE series filter elements.
Drop-in element bowl design for easier installation.
TANK-TOP FILTERS • Patented element bowl hold-down for suction applications.
• O-ring seal between filter housing and tank top.
• Filter housing mounting bolt pattern matches Zinga RF and SRF series
as well as Schroeder ST and RT series housings.
Flows Up To: TR 96 GPM (Return) 32 GPM (Suction) • TS series housings are fully compatible with Schroeder K series elements.
TS 71 GPM (Return) 24 GPM (Suction)
Port Sizes: 1 1/4" & 1 1/2" NPTF
1 5/8" - 12 UN (SAE - 20) Average pressure drop through clean filter with 150 SUS oil at 105˚ F.
1 7/8" - 12 UN (SAE - 24)
1 1/4" BSP
TANK-TOP

TANK-TOP
Pressure: 100 PSI Max. Operating 25
Temperature: Up to +250°F
Application: Suitable for petroleum-based fluid only.
Consult factory for synthetic fluids. 20 ZR E- 409-10

Pressure Drop (PSI)


R E- 409-10
PORT OPTIONS
• NO PORT STANDARD
15 ZR E- 409-03
(4) 5/16” ACCESS COVER
BOLTS SUPPLIED 6.0” • 1/8” N.P.T.F. GAUGE PORT
RIGHT SIDE
PORT OPTIONS IN LOCATION $2 R E- 409-03
• 1 1/4” N.P.T.F. OIL FILL
PORT WITH PLUG
10
• 1 5/8” - 12 S.A.E. O-RING
LEFT SIDE PORT OPTIONS OIL FILL PORT WITH PLUG
1 1/4” & 1 1/2” NPTF, 1 5/8” -
12 UN (SAE - 20), 1 7/8” - 12 6.74” 2
UN (SAE - 24) OR 1 1/4” BSP R E- 409-25
1/8" N.P.T.F.
GAUGE PORT
5
1 NOTE: LOCATION #1 IS
RESERVOIR TOP 3.63” STD. BOTH SIDES WILL
BE PORTED AND
PLUGGED.
1.63” 1 R E- 409-100
BUNA “N” SEALS SUPPLIED
STANDARD (FLUOROCARBON
0
OPTIONAL) 0 30 60 90 120
BY-PASS VALVE SETTINGS Flow Rate (GPM)
3 & 5 PSID (SUCTION)
15, 25, & 50 PSID (RETURN)

MOUNTING BOLTS,
4.61/4.94” DIA. HOLE IN TANK
9.65”
NUTS, & LOCK RE & SRE Element Data: See Pages 45 & 46
WASHERS NOT
SUPPLIED
“RE” & “SRE”
SERIES FILTER ELEMENTS
3, 10, 25 MICRON & 100 MESH
STANDARD (FLUOROCARBON OPTIONAL)
1.25”
• "RE" SERIES FILTER ELEMENTS
USED IN "TR" SERIES HOUSINGS
• "SRE" SERIES FILTER ELEMENTS 2.44” HEX
USED IN "TS" SERIES HOUSINGS 1 1/2” N.P.T.F.

(4) .42” DIA. MOUNTING


HOLES AT 90 DEG. 16 1/2°

45°
6.250 B.C.D.

Patent #5389246
90° TYP.

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
41 42

SRF SERIES Average Pressure Drop Through Clean Filter Assembly With 150 SUS Oil At 105˚ F

SUCTION / RETURN LINE 25 25

TANK-TOP FILTERS
ZSRE409-10

20 20
SRE-409-10
ZSRE-418-10

Pressure Drop (PSI)

Pressure Drop (PSI)


15 ZSR E- 409-03
15
Flows Up To: 83 GPM (Return) 28 GPM (Suction) SRE- 409-03
SRE-418-10

Port Sizes: 1 1/4" & 1 1/2" NPTF ZSRE-418-03


10
1 5/8" - 12 UN (SAE - 20) 10
SRE-418-03
1 7/8" - 12 UN (SAE - 24) SRE-409-10

5
1" & 1 1/4" BSP 5

Pressure: 100 PSI Max Operating SRE-409-100 SRE-418-100


SRE-418-25
Temperature: Up to 250°F Operating 0
0 30 60 90 120
0
TANK-TOP

TANK-TOP
0 30 60 90 120
Application: Petroleum-based fluids Flow Rate (GPM) Flow Rate (GPM)
Consult factory for synthetic fluids Single Length Element Double Length Element

BOTTOM PORT OPTIONS:


1/8" NPTF GAUGE PORT & PIPE PLUG 10
(STANDARD BOTH SIDES)
6.25" BCD (4)
1 1/2" NPT MALE PIPE
(4) 7/16" DIA. CLEARANCE HOLES (RF) 8
(4) 3/8" SELF LOCKING BOLTS STD. (WF)
ZSRE-409-03

Pressure Drop (PSI)


6
SRE-409-10

SRE-409-03
4
1 1 1/4" STANDARD
(6) 5/16" SELF LOCKING BOLS
(SUPPLIED STANDARD) 2
1 1/4" NPT COUPLING SRE-418-100
SRE-409-25
ZSRE-409-10
0
7.0" 0 30 60 90 120
OIL FILL PORT OPTION
Flow Rate (GPM)

Triple Length Element Application: Bottom Flow Filter


PORT OPTIONS: 1/2" STANDARD
1 1/4" & 1 1/2" NPTF
1 5/8" - 12 UN (SAE - 20)
1 7/8" - 12 UN (SAE - 24) 1 1/2" NPT PIPE
3.70" 1" & 1 1/4" BSP

RF = 1/8" BOLT DOWN FLANGE


Additional SRE Element Data: See Page 45
MOUNT SURFACE

1.62"
1/8" THICK BUNA-N GASKET
(STANDARD WITH SRF SERIES)
3" STANDARD
O
SINGLE ELEMENT = 8.5" BY-PASS VALVE: 45
3 & 5 PSID (SUCTION)
DOUBLE ELEMENT = 17.8"
15, 25, & 50 PSID (RETURN)
TRIPLE ELEMENT = 27.1" (RETURN TYPE VALVE SHOWN)
1 1/2" NPT PIPE
SRE OR ZSRE SERIES FILTER ELEMENTS WITH CHECK VALVE
3, 10, 25, & 141 (100 MESH) MICRON FILTRATION

5 3/8" DIA. MOUNTING


2 3/4" (APPX)
4.8" HOLE REQUIRED

Design Features:• Radial seal grommet used in SRE Series filter elements.
• Filter housing mounting bolt pattern matches Zinga RF, TR, and TS
series as well as Schroeder ST, RT, and LRT series housings.
• SRF series housings are fully compatible with Schroeder K series elements.

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
43 44

RF SERIES (100 PSI) Average Pressure Drop Through Clean Filter Assembly With 150 SUS Oil At 105˚ F

WF SERIES (500 PSI) 25

ZR E- 409-10
25

TANK-TOP FILTERS 20
R E- 409-10 20
ZR E- 418-10

Pressure Drop (PSI)

Pressure Drop (PSI)


15 ZR E- 409-03 15
R E - 418-10
R E- 409-03
Flows Up To: 96 GPM (Return) 32 GPM (Suction) ZRE - 418-03
Port Sizes: 1 1/4" & 1 1/2" NPTF 10 10
R E- 418-03
1 5/8" - 12 (SAE - 20) R E- 409-25

1 7/8" - 12 (SAE - 24) 5 5

1" & 1 1/4" BSP


R E- 409-100 R E- 418-100
Max. Operating Pressure: RF - 100 PSI, WF - 500 PSI 0 0
R E- 418-25
0 30 60 90 120
TANK-TOP

TANK-TOP
0 30 60 90 120
Temperature: Up to 250°F Operating Flow Rate (GPM) Flow Rate (GPM)
Application: Petroleum-based fluids only Single Length Element Double Length Element
Consult factory for synthetic fluids
10

8
BOTTOM PORT OPTIONS:
1/8" NPTF GAUGE PORT & PIPE PLUG ZR E- 409-03

Pressure Drop (PSI)


(STANDARD BOTH SIDES)
6.25" BCD (4) 6
1 1/2" NPT MALE PIPE
(4) 7/16" DIA. CLEARANCE HOLES (RF) R E- 409-10
(4) 3/8" SELF LOCKING BOLTS STD. (WF)
R E- 409-03
4

2
R E- 409-100

1 1 1/4" STANDARD ZR E- 409-10


R E- 409-25
(6) 5/16" SELF LOCKING BOLS 0
(SUPPLIED STANDARD) 0 30 60 90 120
1 1/4" NPT COUPLING Flow Rate (GPM)

Triple Length Element Application: Bottom Flow Filter


OIL FILL PORT OPTION 7.0"

PORT OPTIONS:
1 1/4" & 1 1/2" NPTF 1/2" STANDARD
1 5/8" - 12 (SAE - 20)
1 7/8" - 12 (SAE - 24)
RE Element Data: See Pages 46
RF = 3.70" 1" & 1 1/4" BSP 1 1/2" NPT PIPE
WF = 3.83"
RF = 1/8" BOLT DOWN FLANGE
MOUNT SURFACE WF= 3/8" WELD DOWN FLANGE

RF = 1.62"
WF= 1.75" 1/8" THICK BUNA-N GASKET
(STANDARD WITH RF SERIES)
3" STANDARD
O
SINGLE ELEMENT = 8.5" BY-PASS VALVE: 45
3 & 5 PSID (SUCTION)
DOUBLE ELEMENT = 17.8"
15, 25, & 50 PSID (RETURN)
TRIPLE ELEMENT = 27.1" (RETURN TYPE VALVE SHOWN)
1 1/2" NPT PIPE
RE OR ZRE SERIES FILTER ELEMENTS WITH CHECK VALVE
3, 10, 25, & 141 (100 MESH) MICRON FILTRATION

4.8" 5 3/8" DIA. MOUNTING 2 3/4" (APPX)

HOLE REQUIRED

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
45 46

SRE & ZSRE SERIES FILTER ELEMENTS RE & ZRE SERIES FILTER ELEMENTS
Use in SRF & TS Housings Or as Direct Interchange for Schroeder "K" Series Elements. Use in RF, WF & TR Housings
Part Nominal Absolute Media (A) (B) Flow Direction Part Nominal Absolute Media (A) (B) Flow Direction
Number Rating Rating Type ID Length Through Element Number Rating Rating Type ID Length Through Element
SRE40903 ß<4µ(c) = 2 ß11µ(c) = 75 Cellulose 1.61" 9.19" Bi-Directional RE40903 ß<4µ(c) = 2 ß11µ(c) = 75 Cellulose 1.96" 9.19" Bi-Directional
SRE40903AZ** ß<4µ(c) = 2 ß11µ(c) = 75 Aqua-Zorb 1.61" 9.19" Outside to Inside RE40903AZ** ß<4µ(c) = 2 ß11µ(c) = 75 Aqua-Zorb 1.96" 9.19" Outside to Inside
SRE40910 ß5µ(c) = 2 ß19µ(c) = 75 Cellulose 1.61" 9.19" Bi-Directional RE40910 ß5µ(c) = 2 ß19µ(c) = 75 Cellulose 1.96" 9.19" Bi-Directional
SRE40910AZ** ß5µ(c) = 2 ß19µ(c) = 75 Aqua-Zorb 1.61" 9.19" Outside to Inside RE40910AZ** ß5µ(c) = 2 ß19µ(c) = 75 Aqua-Zorb 1.96" 9.19" Outside to Inside
SRE40925 ß19µ(c) = 2 ß36µ(c) = 75 Cellulose 1.61" 9.19" Bi-Directional RE40925 ß19µ(c) = 2 ß36µ(c) = 75 Cellulose 1.96" 9.19" Bi-Directional
TANK-TOP

TANK-TOP
SRE41803 ß5µ(c) = 2 ß11µ(c) = 75 Cellulose 1.61" 18.19" Bi-Directional RE41803 ß5µ(c) = 2 ß11µ(c) = 75 Cellulose 1.96" 18.19" Bi-Directional
SRE41810 ß5µ(c) = 2 ß19µ(c) = 75 Cellulose 1.61" 18.19" Bi-Directional RE41810 ß5µ(c) = 2 ß19µ(c) = 75 Cellulose 1.96" 18.19" Bi-Directional
SRE41825 ß19µ(c) = 2 ß36µ(c) = 75 Cellulose 1.61" 18.19" Bi-Directional RE41825 ß19µ(c) = 2 ß36µ(c) = 75 Cellulose 1.96" 18.19" Bi-Directional
SRE409100* 141 Micron ------------- SS Mesh 1.61" 9.19" Outside to Inside RE409100* 141 Micron ------------- SS Mesh 1.96" 9.19" Outside to Inside
SRE409100R* 141 Micron ------------- SS Mesh 1.61" 9.19" Inside to Outside RE409100R* 141 Micron ------------- SS Mesh 1.96" 9.19" Inside to Outside
SRE409100M* 141 Micron ------------- SS Mesh 1.61" 9.19" Outside to Inside RE409100M* 141 Micron ------------- SS Mesh 1.96" 9.19" Outside to Inside
SRE409100MR* 141 Micron ------------- SS Mesh 1.61" 9.19" Inside to Outside RE409100MR* 141 Micron ------------- SS Mesh 1.96" 9.19" Inside to Outside

ZSRE40903 ß<4µ(c) = 2 ß7µ(c) = 1000 Z-Glass 1.61” 9.19” Outside to Inside ZRE40903 ß<4µ(c) = 2 ß7µ(c) = 1000 Z-Glass 1.96” 9.19” Outside to Inside
ZSRE40903R ß<4µ(c) = 2 ß7µ(c) = 1000 Z-Glass 1.61” 9.19” Inside to Outside ZRE40903R ß<4µ(c) = 2 ß7µ(c) = 1000 Z-Glass 1.96” 9.19” Inside to Outside
ZSRE40910 ß<4µ(c) = 2 ß12µ(c) = 1000 Z-Glass 1.61” 9.19” Outside to Inside ZRE40910 ß<4µ(c) = 2 ß12µ(c) = 1000 Z-Glass 1.96” 9.19” Outside to Inside
ZSRE40910R ß<4µ(c) = 2 ß12µ(c) = 1000 Z-Glass 1.61” 9.19” Inside to Outside ZRE40910R ß<4µ(c) = 2 ß12µ(c) = 1000 Z-Glass 1.96” 9.19” Inside to Outside
ZSRE41803 ß<4µ(c) = 2 ß7µ(c) = 1000 Z-Glass 1.61” 18.19” Outside to Inside ZRE41803 ß<4µ(c) = 2 ß7µ(c) = 1000 Z-Glass 1.96” 18.19” Outside to Inside
ZSRE41803R ß<4µ(c) = 2 ß7µ(c) = 1000 Z-Glass 1.61” 18.19” Inside to Outside ZRE41803R ß<4µ(c) = 2 ß7µ(c) = 1000 Z-Glass 1.96” 18.19” Inside to Outside
ZSRE41810 ß<4µ(c) = 2 ß12µ(c) = 1000 Z-Glass 1.61” 18.19” Outside to Inside ZRE41810 ß<4µ(c) = 2 ß12µ(c) = 1000 Z-Glass 1.96” 18.19” Outside to Inside
ZSRE41810R ß<4µ(c) = 2 ß12µ(c) = 1000 Z-Glass 1.61” 18.19” Inside to Outside ZRE41810R ß<4µ(c) = 2 ß12µ(c) = 1000 Z-Glass 1.96” 18.19” Inside to Outside

Note: Note:
* 1. 100 mesh stainless steel wire cloth standard for 141 micron elements. 30, 60, and 200 mesh optional. * 1. 100 mesh stainless steel wire cloth standard for 141 micron elements. 30, 60, and 200 mesh optional.
** 2. A
 qua-Zorb filter media retains up to 11 oz. of free water. Any absorbed water cannot be liberated from the ** 2. A
 qua-Zorb filter media retains up to 11 oz. of free water. Any absorbed water cannot be liberated from
media. As the element becomes saturated with water, the Aqua-Zorb media continues to swell, and will the media. As the element becomes saturated with water, the Aqua-Zorb media continues to swell, and
ultimately curtail flow through the filter. Not for use with water-glycols. will ultimately curtail flow through the filter. Not for use with water-glycols.
3. SRE and ZSRE are equipped with a Buna-N grommet (radial) seal as standard. (Fluorocarbon Available) 3. RE and ZRE are equipped with a Buna-N grommet (radial) seal as standard. (Fluorocarbon Available)
A Average Pressure Drop Through Clean Filter Assembly With 150 SUS Oil At 105˚ F

Magnetic 25 25

Elements ZR E- 409-10

20 20
R E- 409-10
Part Numbers ZR E- 418-10

Pressure Drop (PSI)


Pressure Drop (PSI)
RE/SRE-409-100M
B 15 ZR E- 409-03 15
RE/SRE-409-100MR R E - 418-10
R E- 409-03
(NOT FOR USE IN TR/TS) ZRE - 418-03
10 10
Three 4" dia. x 5/8" R E- 418-03
R E- 409-25
thick ceramic magnets
5 5

Four 100 mesh R E- 409-100 R E- 418-25


R E- 418-100
0 0
3.91 wire cloth sections 0 30 60 90 120 0 30 60 90 120
Flow Rate (GPM) Flow Rate (GPM)

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
47 48

WF-2 SERIES Optional Mounting Flanges

TANK-TOP FILTER 45
o
PORT CENTER LINE
OF TOP CASTING
Bolt Flange (Part Number WF-10):
• For bolt down installation to reservoir.
Flows Up To: 300 GPM (Return) 100 GPM (Suction) 8.38" BCD • Bolt flange supplied with 1/8" thick gasket.
Port Sizes: 2" NPTF
2" 4-Bolt Flange Weld Flange (Part Number WF-09):
2 1/2" 4-Bolt Flange • For weld in place installation on reservoir.
3" 4-Bolt Flange • Weld flange identical to bolt flange except without bolt
Pressure: 300 PSI Max. Operating Pressure clearance holes and gasket.
Temperature: Up to 250°F
Application: Petroleum-based fluids. (4) .56" DIA.
o
HOLES @ 90
TANK-TOP

TANK-TOP
7.03" ID
9.25" OD .19"

OPTIONAL OIL FILL PORT


1 1/4" N.P.T.F. PIPE PLUG
WITH CERAMIC MAGNET INSERT
(3/4" SQ. SOCKET DRIVE)

Note:
• 7.06" to 7.38" dia. hole in reservoir wall required for proper installation.
• Flanges can be welded to filter housings by factory as an extra cost option. Specify the desired height
required from port center line to mounting surface (reservoir wall), 2.5" minimum.

2” NPTF, 2” 4-BOLT FLANGE,


2 1/2” 4-BOLT FLANGE,
OR 3” 4-BOLT FLANGE

OPTIONAL BY-PASS
VALVE SETTINGS:
3 & 5 PSID (SUCTION)
15, 25, & 50 (RETURN)

2.5" MINIMUM

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
49 50

WE & ZWE SERIES FILTER ELEMENTS TYPICAL TANK-TOP FILTER INSTALLATIONS


For use in WF2 Housings
Part Nominal Absolute Media (A) Flow Direction SRF / RF / WF SERIES
Number Rating Rating Type Length Through Element NOTE: F
 or suction applications use “100R” elements
WE50903 ß<4µ(c) = 2 ß 11µ(c)
= 75 Cellulose 9.13" Bi-Directional (Except “Bottom Flow” Mount)
WE50910 ß5µ(c) = 2 ß 19µ(c)
= 75 Cellulose 9.13" Bi-Directional
*WE509100 141 Micron SS Mesh 9.13" Outside To Inside
*WE509100R 141 Micron SS Mesh 9.13" Inside To Outside
WE50925 ß19µ(c) = 2 ß 36µ(c)
= 75 Cellulose 9.13" Bi-Directional
WE51803 ß<4µ(c) = 2 ß 11µ(c)
= 75 Cellulose 18.13" Bi-Directional
**WE51803AZ ß<4µ(c) = 2 ß 11µ(c)
= 75 Aqua-Zorb 18.13" Bi-Directional
WE51810 ß5µ(c) = 2 ß = 75 Cellulose 18.13" Bi-Directional
TANK-TOP

TANK-TOP
19c)

**WE51810AZ ß5µ(c) = 2 ß 19c)


= 75 Aqua-Zorb 18.13" Bi-Directional
*WE518100 141 Micron SS Mesh 18.13" Outside To Inside
*WE518100R 141 Micron SS Mesh 18.13" Inside To Outside
WE51825 ß19µ(c) = 2 ß 36µ(c)
= 75 Cellulose 18.13" Bi-Directional
ZWE50903 ß<4µ(c) = 2 ß 7µ(c)
= 1000 Z-Glass 9.13" Outside To Inside
ZWE50903R ß<4µ(c) = 2 ß 7µ(c)
= 1000 Z-Glass 9.13" Inside To Outside
ZWE50910 ß<4µ(c) = 2 ß 12µ(c)
= 1000 Z-Glass 9.13" Outside To Inside
ZWE50910R ß<4µ(c) = 2 ß 12µ(c)
= 1000 Z-Glass 9.13" Inside To Outside
ZWE51803 ß<4µ(c) = 2 ß 7µ(c)
= 1000 Z-Glass 18.13" Outside To Inside
ZWE51803R ß<4µ(c) = 2 ß 7µ(c)
= 1000 Z-Glass 18.13" Inside To Outside
TANK FILTER FOR SUCTION LINE APPLICATION
ZWE51810 ß<4µ(c) = 2 ß 12µ(c)
= 1000 Z-Glass 18.13" Outside To Inside OR BOTTOM CONNECTION TO RV SERIES
PUMP INLET PORT: RETURN LINE CHECK VALVE
ZWE51810R ß<4µ(c) = 2 ß 12µ(c)
= 1000 Z-Glass 18.13" Inside To Outside TANK DIFFUSER FOR RETURN LINE APPLICATION
MALE PIPE OR
MALE HOSE BARB
Note:
* 1. 100 mesh stainless steel wire cloth standard for 141 micron elements. 30, 60, and 200 mesh optional.
** 2. A
 qua-Zorb filter media retains up to 11 oz. of free water. Any absorbed water cannot be liberated from the WF-2 SERIES
media. As the element becomes saturated with water, the Aqua-Zorb media continues to swell, and will
ultimately curtail flow throughout the filter. Not for use with water-glycols.

25 25 NOTE: F
 or suction applications
WE-518-03 WE-518-10
"B" LENGTH
use “100R” elements
20 "B" LENGTH 20
Pressure Drop (PSI)

ZWE-509-10
Pressure Drop (PSI)

ZWE-509-03 "A" LENGTH


15 "A" LENGTH
15

WE-509-03 WE-509-10
"A" LENGTH
3.4"
10 "A" LENGTH 10
ZWE-518-03
"B" LENGTH
5 5 WE-518-10
WE-518-03 "C" LENGTH &
"C" LENGTH ZWE-518-10
0 "B" LENGTH
0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Flow Rate (GPM) Flow Rate (GPM)

25 25

A
20 20
WE-518-100
Pressure Drop (PSI)

"B" LENGTH
Pressure Drop (PSI)

15 15

WE-509-100
10 10
"A" LENGTH
WE-509-25
"A" LENGTH WE-518-25
5 "B" LENGTH
5
WE-518-100
"C" LENGTH
0 0
0 50 100 150 200 250 300
Flow Rate (GPM)
0 50 100 150
Flow Rate (GPM)
200 250 300 5.18"
TANK FILTER FOR SUCTION LINE APPLICATION
Average pressure drop through clean assembly with 150 SUS oil at 105° F TANK DIFFUSER FOR RETURN LINE APPLICATION

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
51 52

SS & MS SERIES TF SERIES


INTERNALLY MOUNTED TANK FILTER
TANK FILTER EXTERNALLY MOUNTED
Port Sizes: 3/8" Through 6" NPTF Port Sizes: 3/8” Through 4” NPTF
Media: 100 Mesh Standard Media: 100 Mesh Standard
Optional By-pass: 3 PSI (6” Hg) or 5 PSI (10” Hg) Optional By-pass: 3 PSI (6” Hg) or 5 PSI (10” Hg)
Operating Temperature: Up to 250°F­ Operating Temperature: Up to 250°F
Other Options: Magnetic Options Available
STRAINERS

STRAINERS
A B C D F Rated Flow
A B C D Rated Flow E
Model Outlet Port Wrench Flat Overall Length OD @ 5 Ft/Sec Model Outlet Port Hex Size Male Thread Fitting Length Cover Dia. @ 5 Ft/Sec
TF0310X0* 3/8" NPTF 1.2" 1" NPTF 1.1" 2.6" 1.1" 3 GPM
MS030X0* 3/8" NPTF 1.2" 2.6" 1.1" 3 GPM
TF0510XX* 1/2" NPTF 1.2" 1" NPTF 1.1" 4.9" 1.1" 5 GPM
SS030X0* 3/8" NPTF 1.13" 2.2" 3.2" 3 GPM
TF0712XX* 3/4" NPTF 1.5" 1 1/4" NPTF 1.1" 6.9" 1.5" 8 GPM
MS050X0* 1/2" NPTF 1.2" 2.6" 1.1" 5 GPM TF1015XX* 1" NPTF 1.75" 1 1/2" NPTF 1.1" 6.9" 1.7" 14 GPM
SS050X0* 1/2" NPTF 1.13" 2.2" 3.2" 5 GPM TF1030XX* 1" NPTF 2.5" 3" NPTF 1.5" 4.7" 3.2" 14 GPM
MS070XX* 3/4" NPTF 1.5" 3.9" 1.5" 8 GPM TF1220XX* 1 1/4" NPTF 2.1" 2" NPTF 1.2" 9.1" 2.2" 23 GPM
SS070XX* 3/4" NPTF 1.75" 3.6" 3.2" 8 GPM TF1230XX* 1 1/4" NPTF 2.5" 3" NPTF 1.5" 6.7" 3.2" 23 GPM
MS100XX* 1" NPTF 1.75" 3.9" 1.7" 14 GPM TF1530XX* 1 1/2" NPTF 2.5" 3" NPTF 1.5" 8.7" 3.2" 32 GPM
SS100XX* 1" NPTF 1.75" 4.6" 3.2" 14 GPM TF1630XX* 1 5/8"-12 (SAE-20) 2.5" 3" NPTF 1.5" 8.7" 3.2" 14 GPM
SS120XX* 1 1/4" NPTF 2.25" 6.6" 3.2" 23 GPM TF1830XX* 1 7/8"-12 (SAE-24) 2.5" 3" NPTF 1.5" 8.7" 3.2" 21 GPM
SS150XX* 1 1/2" NPTF 2.25" 8.6" 3.2" 32 GPM TF2030XX* 2" NPTF 3.06" 3" NPTF 1.6" 8.8" 3.2" 53 GPM
SS154XX* 1 1/2" NPTF 2.25" 7.2" 4.2" 32 GPM TF2040XX* 2" NPTF 4.13" 4" NPTF 1.8" 7.7" 4.2" 53 GPM
SS200XX* 2" NPTF 3.0" 7.2" 4.2" 53 GPM TF2540XX* 2 1/2" NPTF 4.13" 4" NPTF 2.1" 9.7" 4.2" 75 GPM
SS250XX* 2 1/2" NPTF 3.5" 9.3" 4.2" 75 GPM TF3040XX* 3" NPTF 4.13" 4" NPTF 2.1" 12.7" 4.2" 116 GPM
SS300XX* 3" NPTF 4.0" 12.4" 4.2" 116 GPM TF4060XX* 4" NPT 5.8" 6" NPTF 2.3" 12.4" 6.0" 200 GPM
SS400XX* 4" NPT NA 20.1" 9.0" 200 GPM All strainers are rated at 5 ft/sec with a pressure drop of under 1” Hg (1/2 PSI) with 150 SUS oil.
SS600XX* 6" NPT NA 20.1" 9.0" 450 GPM
*Additional information required to place an order. Contact factory for assistance.
All strainers are rated at 5 ft/sec with a pressure drop of under 1” Hg (1/2 PSI) with 150 SUS oil.
*Additional information required to place an order. Contact factory for assistance.

REVERSE TAPER
All Zinga series tank filter end caps have
reverse taper wall construction. This feature
prevents bond failure by ensuring a positive
mechanical interlock with the epoxy adhesive.
Excellent for rough-terrain vehicle applications.

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
53 54

TFS SERIES TF & TFS SERIES


STEEL BUSHING TANK FILTER O-RING SEAL TANK STRAINER
EXTERNALLY MOUNTED & MOUNTING WELD COLLAR

Port Sizes: 1/2” Through 3” NPT Port Sizes: 1 5/8”-12 SAE to 2 1/2”-12 SAE
Media: 100 Mesh Standard Media: 100 Mesh Standard
Optional By-pass: 3 PSI (6” Hg) or 5 PSI (10” Hg) Optional By-pass: 3 PSI (6” Hg) or 5 PSI (10” Hg)
Operating Temperature: Up to 250°F­ Operating Temperature: Up to 250°F­

A
STRAINERS

STRAINERS
K H

D
C
E F
G
A B C D E Rated Flow
Model Outlet Port Hex Size Male Thread Overall Length Cover Dia. @ 5 Ft/Sec
Design provides leak-proof service by using a male straight-thread o-ring seal that mates
TFS0510XX* 1/2" NPT 1.38" 1" NPT 5.3" 1.1" 5 GPM
with a female straight-thread collar welded to the reservoir.
TFS0712XX* 3/4" NPT 1.80" 1 1/4" NPT 6.9" 1.5" 8 GPM
TFS1015XX* 1" NPT 2.23" 1 1/2" NPT 7.1" 1.7" 14 GPM
TFS1220XX* 1 1/4" NPT 2.58" 2" NPT 9.1" 2.2" 23 GPM
TFS1540XX* 1 1/2" NPT 2.70" 4" NPT 9.2" 4.2" 32 GPM T A C H Rated Flow
D E F G
TFS2030XX* 2" NPT 3.30" 3" NPT 9.4" 3.2" 53 GPM Model Thread Outlet Port Hex Dia. @ 5 Ft/Sec
TFS2540XX* 2 1/2" NPT 3.83" 4" NPT 9.1" 4.2" 75 GPM TFS1625XX* 2 1/2"-12 UN-2A 1 5/8"-12 (SAE-20) 2.75" .8" 1.3" 7.9" 9.2" 2.2" 14 GPM
TFS3040XX* 3" NPT 4.65" 4" NPT 9.4" 4.2" 116 GPM TF1634XX* 3 3/8"-12 UN-2A 1 5/8"-12 (SAE-20) 2.44" .9" 1.5" 5.2" 6.7" 3.2" 14 GPM
TF1834XX* 3 3/8"-12 UN-2A 1 7/8"-12 (SAE-24) 2.44" .9" 1.5" 7.2" 8.7" 3.2" 21 GPM
All strainers are rated at 5 ft/sec with a pressure drop of under 1” Hg (1/2 PSI) with 150 SUS oil.
TFS3234XX* 3 3/8"-12 UN-2A 2 1/2"-12(SAE-32) 3.5" .7" 1.2" 7.8" 9.1" 3.2" 39 GPM
*Additional information required to place an order. Contact factory for assistance.
All strainers are rated at 5 ft/sec with a pressure drop of under 1” Hg (1/2 PSI) with 150 SUS oil.
*Additional information required to place an order. Contact factory for assistance.

Notes: Weld Collars


1. Buna-N O-ring supplied as standard, fluo- T K
rocarbon available. Part Number Thread Dia.
2. TFS: Steel-reducer bushing. WC1225 2 1/2" - 12 UN-2B 3.9"
TF: Cast-aluminum reducer bushing. WC1634 3 3/8" - 12 UN-2B 5.0"
Please Order Separately

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
55 56

TF SERIES BTF SERIES


MALE NPTF HOSE BEAD TANK FILTER &
TANK FILTER MOUNTING WELD COLLAR
Port Sizes: 2” Through 2 1/2” NPTF Port Sizes: 3/4” Through 1 1/4” Hose
Media: 100 Mesh Standard External Thread: NPTF and Straight w/ O-ring Seal
Optional By-pass: 3 PSI (6” Hg) or 5 PSI (10” Hg) Media: 100 Mesh Standard
Operating Temperature: Up to 250°F Optional By-pass: 3 PSI (6” Hg) or 5 PSI (10” Hg)
OperatingTemperature: Up to 250°F

TF 2-1/2" HEX
100 MESH STAINLESS STEEL Hose Bead to Male Straight-Thread Fitting O-Ring and Mounting Weld Collar
WIRE CLOTH STANDARD
ALUMINUM BUSHING (30, 60, & 200 MESH OPTIONAL) 100 MESH STAINLESS
OPTIONAL BY-PASS VALVE HOSE BEAD CONNECTOR OPTIONAL BY-PASS VALVE
STEEL WIRE CLOTH
BUNA 'N' O-RING STANDARD STANDARD (30, 60, &
(FLUOROCARBON OPTIONAL) 200 MESH OPTIONAL)

2.1"
STRAINERS

STRAINERS
.5" .38" 1.25" A F

10.8"
TF-2020 Used As A Strainer In A 55 Gallon
Barrel With a 2” Ball Valve Directly Attached
13.7" C G E

Weld Collar
TFS STEEL BUSHING 100 MESH STAINLESS STEEL Part B
WIRE CLOTH STANDARD
(30, 60, & 200 MESH OPTIONAL)
A B C E F G Rated Flow Number Thread O.D.
OPTIONAL BY-PASS VALVE Model
Thread Hex Length Dia. Length 5 Ft/Sec WC0716 1 5/8"-12UN-2B 2.75"
BTF0716XX* .8" 1 5/8”-12UN-2A 1.88" 6.4" 1.5" 1.6" 5 GPM WC1018 1 7/8"-12UN-2B 3.06"
RESERVOIR
BTF1018XX* 1.0" 1 7/8”-12UN-2A 2.13" 6.4" 1.7" 1.7" 10 GPM WC1225 2 1/2"-12UN-2B 3.88"
2.1" BTF1225XX* 1.3" 2 1/2”-12UN-2A 2.75" 8.4" 2.7" 1.9" 16 GPM Ordered Separately From Filter

*Additional information required to place an order. Contact factory for assistance.


10.7"
Hose Bead-to-Pipe Thread Seal
14.2"
Suction Line Straining Application 100 MESH STAINLESS
STEEL WIRE CLOTH OPTIONAL BY-PASS VALVE
STANDARD (30, 60, &
200 MESH OPTIONAL)
HOSE BEAD CONNECTOR
D

Commonly Ordered Configuration


TFS2020XX* A F

All strainers rated at 5 ft/sec with a pressure drop of under 1” Hg (1/2 PSI) with 150 SUS oil.
*Additional information required to place an order. Contact factory for assistance. B
C G E

A B C D E F G Rated Flow
Model
Thread Hex Length Length Dia. Length 5 Ft/Sec
BTF0712XX* .8" 1 1/4" NPTF 1.75" 1.2" 7.0" 1.5" 1.2" 5 GPM
BTF1015XX* 1.0" 1 1/2" NPTF 2.00" 1.2" 7.0" 1.7" 1.2" 10 GPM
BTF1220XX* 1.3" 2" NPTF 2.50" 1.3" 9.1" 2.7" 1.3" 16 GPM

All strainers rated at 5 ft/sec with a pressure drop of under 1” Hg (1/2 PSI) with 150 SUS oil.
*Additional information required to place an order. Contact factory for assistance.

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
57 58

TD SERIES TD SERIES
TANK DIFFUSERS O-RING SEAL TANK DIFFUSER

Port Sizes: 3/8" Through 6" NPTF Port Sizes: SAE-20 & SAE-24
Operating Temperature: Up to 250°F­ Operating Temperature: Up to 250°F­

INTERNALLY MOUNTED
PMI Series

Model A B C D Rated Flow Ratio of Perf Mtl Open


Number Inlet Port Wrench Flat Outside Dia. Overall Length (At 15 Ft/Sec) Area vs. Pipe Int Area
TANK DIFFUSERS

TANK DIFFUSERS
TD100PMI 1" NPTF 1.75" 3.2" 3.6" 40 GPM 27 : 1
TD125PMI 1 1/4" NPTF 2.25" 3.2" 4.6" 70 GPM 22 : 1
TD150PMI 1 1/2" NPTF 2.25" 3.2" 5.6" 95 GPM 21 : 1
TD200PMI 2" NPTF 3.0" 4.2" 6.2" 157 GPM 17 : 1

A B C
EXTERNALLY MOUNTED Inlet Overall Rated Flow Open Area
Model Port Length Length @15 Ft/Sec Ratio
PME Series TD1634PME 1 5/8”-12UN (SAE-20 ) 3.2” 4.7” 43 GPM 27:1
TD1834PME 1 7/8”-12UN ( SAE-24 ) 4.2” 5.7” 64 GPM 24:1

Please Order Weld Collar Part Number WC-1634 Separately From Tank Diffuser

Model A B C D Rated Flow Ratio of Perf Mtl Open


Number Inlet Port Wrench Flat Male Thread Overall Length (At 15 Ft/Sec) Area vs. Pipe Int Area
TD0310PME
TD0510PME
3/8" NPTF
1/2" NPTF
1.2"
1.12"
1" NPTF
1" NPTF
3.0"
4.0"
9 GPM
9 GPM
25 : 1
25 : 1 WC-1634
TD0712PME
TD1015PME
3/4" NPTF
1" NPTF
1.5"
1.75"
1 1/4" NPTF
1 1/2" NPTF
3.9"
4.9"
25 GPM
40 GPM
18 : 1
19 : 1
MOUNTING WELD COLLAR
TD1030PME 1" NPTF 2.5" 3" NPTF 4.7" 40 GPM 31 : 1
TD1220PME 1 1/4" NPTF 2.1" 2" NPTF 5.1" 70 GPM 14 : 1
TD1230PME 1 1/4" NPTF 2.5" 3" NPTF 4.7" 70 GPM 18 : 1
TD1530PME 1 1/2" NPTF 2.5" 3" NPTF 5.7" 95 GPM 18 : 1
TD2040PME 2" NPTF 4.1" 4" NPT 6.8" 157 GPM 17 : 1
TD2540PME 2 1/2" NPTF 4.1" 4" NPT 10.8" 224 GPM 22 : 1
TD3040PME 3" NPTF 4.1" 4" NPT 10.8" 346 GPM 15 : 1
TD4060PME 4" NPTF 5.8" 6" NPT 17.5" 595 GPM 21 : 1

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
59 60

RB SERIES WSFB SERIES


RESERVOIR BREATHERS ECONOMICAL RESERVOIR
FILLER BREATHER

• 3/4” NPTF or 1-1/16” UN Thread Mount • Black Painted Weather-Resistant Cover


• Optional 3, 5, & 10 Pressure Relief Valve • 10-Micron Foam Filter Element
• Durable Weather-Resistant Nylon Plastic Cover • Basket-Length Dipstick
• Lock Tab

LOCK TAB
5/16" HOLE

10 MICRON
FOAM ELEMENT
OPTIONAL PRESSURE RELIEF VALVE
3, 5, & 10 P.S.I.PRESSURE RELIEF VALVE 1"
(2) RUBBERIZED CORK
SETTINGS AVAILABLE (ALL RELIEF VALVES GASKETS
HAVE 0.2 P.S.I. VACUUM 1 1/2"
RELIEF STD.)

WSFB10-6S = 8 1/16"
WSFB10-4S = 6 1/16" 30 MESH
3.27” DIA. EPOXY COATED
DIPSTICK CUT MESH BASKET
WSFB10-6S = 5 3/4" TO BASKET LENGTH
ACCESSORIES

ACCESSORIES
WSFB10-4S = 3 3/4"

1 15/16" Dia

o
2.75" 60 TYP
3/4" NPTF 2.88" BCD
OR 1 1/16" MOUNTING
UN (SAE-12)
FLANGE
(6) 10 X 32 X 1/2LG
SELF TAPPING SCREWS
PROVIDED FOR MOUNTING
3 5/16 " Dia

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
61 62

FB SERIES FBR SERIES


RESERVOIR RAISED
FILLER BREATHERS FILLER BREATHERS

• 10-Micron Foam Filter Element* • 1 1/2” and 3” Risers


• Cap-To-Base Chain Connection • 10-Micron Foam Filter Element
• Aluminum and Nylon Cover Options • Cap-To-Base Chain Connection
• Wire Mesh-Lined Basket Available • Aluminum and Nylon Cover Options
• 1” Steel Weldable Riser Available (PN: FB43) • Wire Mesh-Lined Basket Available

OPTIONAL PRESSURE RELIEF VALVE


3, 5, & 10 PSI SETTINGS AVAILABLE
3.27" DIA DIA.
0.2 PSI VACUUM RELIEF STANDARD

10 MICRON FOAM FILTER


ELEMENT STANDARD
(ALL RELIEF VALVES HAVE 0.2
P.S.I. VACUUM RELIEF STD.)

4.9"

3.06" 3.4"
SIX (6) #10-32 X 1/3" LG.
THREAD CUTTING
SCREWS STANDARD .06 " 1.56"

2.750" B.C.D.( x6) BUNA-N GASKET


2.875"
TO FIT BASKET MOUNTING DEPTH TO FIT BASKET
ACCESSORIES

ACCESSORIES
(13.7” STANDARD WHEN (12.6" FTBR15 W/O BASKET)
3.61” BASKET NOT ORDERED) 3.6"
5.61” 5.6" (11.1" FTBR30 W/O BASKET)
OPTIONAL PERFORATED METAL 8.6"
8.61”
11.61” BASKET 11.6"
(30, 60, 100, & 200 MESH
STAINLESS STEEL WIRE CLOTH
LINER AVAILABLE)
OPTIONAL DIPSTICK
2.1" DIA.

2.1 DIA FBR30 FBR15

Average Pressure Drop Through Assembly Without Relief Valve Average Pressure Drop Through Assembly Without Relief Valve

10 0.4 10 0.4

9 9

8 8
0.3 0.3
7 7
PRESSURE DROP

PRESSURE DROP
PRESSURE DROP

PRESSURE DROP
6 6
(IN H20)

(IN H20)
(PSI)

(PSI)
5 0.2 5 0.2

4 4

3 3
0.1 0.1
2 2

1 1

0 0 0 0
0 5 10 15 20 25 30 35 0 50 100 150 200 250 0 5 10 15 20 25 30 35 0 50 100 150 200 250
FLOW RATE OIL LEVEL CHANGE RATE FLOW RATE OIL LEVEL CHANGE RATE
(CFM) (GPM) (CFM) (GPM)

*Spin-on element filler breather available for areas where filtration down to 1 micron particle removal is required.

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
63 64

TB SERIES TBN310 SERIES


TANK BREATHERS SPIN-ON BREATHER
CONVERT SPIN-ON ELEMENTS
TO TANK BREATHERS
• 3/4” NPTF adapter
• Steel Spin-on Housing Design
• Air Flow Rates to 40 SCFM
10
AE03 • 2-Micron Particle Retention
9

PRESSURE DIFFERENTIAL (IN H20)


8
BE10
7
LE03
6 45
5
SE03 O 3.8"
40
4

3 35

PRESSURE DROP (IN H20)


2
30
1

0 25
0 10 20 30 40 50 60 70 80
FLOW (SCFM)
3.8" 20

5.1" 15
E
10
0.4
5
PRESSURE DIFFERENTIAL (PSI)

BE10
1 1/4" HEX 0
0.3
Spin-On 0 5 10 15 20 25 30 35 40
Filter Element 3/4" NPT
AE03 SE03
FLOW (SCFM)
D 0.2
LE03

1.8
TB Series
0.1
Tank Breather
ACCESSORIES

ACCESSORIES
Adapter 1.6
Coupling Mount 1.4
0.0
0 100 200 300 400 500 600

PRESSURE DROP (PSI)


FLOW (GPM) 1.2
Hydraulic Reservoir
1
Average Pressure Drop Through Assembly
0.8

0.6
Note: S
 pin-on filters with anti-drain back valves should not be
used for breather applications. Zinga standard spin-on 0.4
filters do NOT have anti-drain back valves.
0.2

0
A B C D E Air Filtration * Maximum 0 50 100 150 200 250 300
Adapter Mount Spin-On Adapter Spin-On Assy Element @ 99% Air Flow OIL LEVEL EXCHANGE RATE (GPM)
Number Thread Thread Length Series Height Diameter Efficiency scfm / gpm
TB050 1/2” NPT 3/4”-16 UNF 1.6” BE10 5.2” 3.1” 2 micron 8 / 60
TB075 3/4” NPT 1”-12 UNF 2.0” AE03 7.3” 3.7” 1 micron 14 / 104
Design Features:
AE10 7.3” 2 micron 13 / 97 • Integral 3/4” NPT Male Nylon Mounting Stem
AE10L 10.6” 2 micron 14 / 104 • Direct Interchange for Competitor 310 product.
* Based on maximum pressure drop of 5 Inches H2O (0.18 PSID) through clean filter element • 99% Removal Efficiency of Particles 2 Microns and Larger

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
65 66

GV & CI SERIES GVL & CIL SERIES


FILTER GAUGES STAINLESS STEEL
VACUUM & PRESSURE GLYCERIN-FILLED
FILTER GAUGES
• Black Steel Case • Stainless Steel Case
• Brass Stem • Brass Stem
• Acrylic Lens • Acrylic Lens
• Temperature: -40 to +200°F Operating Temperatures • Shock- and Vibration-Resistant
• Temperature: -40 to +200°F Operating Temperatures

VACUUM GAUGES (Suction Line Filter Installations) VACUUM GAUGES (Suction Line Filter Installations)

Part No. GV-05 Part No. GV-10 Part No. GV-05L Part No. GV-10L
For Use With 3 PSI For Use With 5 PSI For Use With 3 PSI For Use With 5 PSI
ACCESSORIES

ACCESSORIES
Filter By-Pass Valve Filter By-Pass Valve Filter By-Pass Valve Filter By-Pass Valve

PRESSURE GAUGES (Return Line Filter Installations) PRESSURE GAUGES (Return Line Filter Installations)

Part No. CI-12 Part No. CI-20 Part No. CI-40 Part No. CI-20L
For Use With 15 PSI For Use With 25 PSI For Use With 50 PSI For Use With 25 PSI
Filter By-Pass Valve Filter By-Pass Valve Filter By-Pass Valve Filter By-Pass Valve

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
67 68

LG SERIES SG SERIES
GAUGES RESERVOIR
GLYCERIN FILLED SIGHT LEVEL GAUGES

• Accuracy +/- 1.5% full scale • Temperature: 212° F Max.


• 2 1/2” dia. 304 stainless steel case • Optional Thermometer
• Glycerin filled • Optional Guards
• Dual Scale: PSI & Bar • UV-Resistant Housing
• Temperature: -40 to +200°F Operating Temperatures

For use with petroleum-base and water-base hydraulic fluids. Consult factory for other fluids.

Model Number A B C D E
2.50" 1.23" SG03XX0* 3.00” 4.22” 1.22” 0.81” 1.16”
.24" SG03XXG* 3.00” 4.75” 1.75” 0.93” 0.82”
SG05XX0* 5.00” 6.22” 1.22” 0.81” 1.16”
SG05XXG* 5.00” 6.75” 1.75” 0.93” 0.82”
SG05XXN* 5.00” 6.75” 1.75” 0.93” 0.82”
SG10XX0* 10.00” 11.22” 1.22” 0.81” 1.16”
SG10XXG* 10.00” 11.75” 1.75” 0.93” 0.82”
.51" *Additional information required to place an order. Contact factory for assistance.
2.10" 55" (SQ) No Guard With Guard

1/4" NPT

Bottom Connection
OE-1 SERIES
ACCESSORIES

ACCESSORIES
OIL-EYE

2.6"8 2.1"3
2.1"5 1.2"6

• Fluid Level Oil Eye and Steel Weld Port


2.4"4 • For Use with Petroleum-Base and Water-Base Hydraulic
Fluids
• Temperature: -65° to 150°F for Pressures up to 400 PSI
(Max Temperature 212°F for Non-Pressurized Applications
1/4" NPT • Sight Glass Designed for Use with SAE-8 Port Geometry
.26" .55" (SQ)

Center Back Connection

All gauges standard with 1/4" NPT connections. Other connections available by special order.

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
69 Low Pressure Visual Indicator 70
200 psi max Operating Pressure
Temperatures up to 150˚F
DIFFERENTIAL PRESSURE (∆P) INDICATORS Automatic Resetting
Factory Installed. Available as kit for field replacement. DIFFERENTIAL PRESSURE (∆P) INDICATORS
LowFor use with
Pressure DF, Indicator
Visual SF, MF, MFT, & ZDF Series Only
200 psi max Operating Pressure
DP03 Series Temperatures up to 150˚F DP06 Series
Automatic Resetting
Low-Pressure Visual Indicator Cartridge-Style Single Wire DC Indicator
.88
.88"
200Factory
PSI Installed. Available as kitPressure
max Operating for field replacement. 200mA @ 36VDC
For use with DF, SF,
Temperatures upMF,to MFT,
150˚F& ZDF Series Only Momentary - Normally Open Circuit
Automatic Resetting 3000 PSI max Operating Pressure (6000 PSI for 80 PSID units)
RED POP-UP
INDICATOR Factory Installed. Available as kit for field replacement. Temperatures up to 200˚F
For use with DF, SF, MF, MFT, & ZDF Series Only #8-32 THREADED .81 Automatic Resetting
.59" POST CONNECTOR Factory Installed. Available as kit for field replacement.
Ground Through Filter Head to Chassis. (In Oil)

.88
Cartridge Style Visual Indicator
3000 psi max Operating Pressure (6000 psi for 80 psid units)
RED POP-UP Temperatures up to 200˚F Chassis Ground
DP04 Series INDICATOR
Automatic Resetting
1.72 .88 1.062
Factory Installed. Available
Cartridge-Style as kit for field replacement.
Visual Indicator INDICATOR PORT DETAIL .816
.811
Cartridge
3000 PSI Stylemax
VisualOperating
Indicator Pressure (6000 PSI for 80 PSID units) .687
3000 psi max Operating
Temperatures Pressure
up to 200˚F(6000 psi for 80 psid units) .682
RED POP-UP .040
Temperatures
AutomaticupResetting
to 200˚F .507 .005
INDICATOR 15 .499
Automatic
FactoryResetting
Installed. Available as kit for field replacement. 45 .110
1.72
Factory Installed. Available as kit for field replacement. TAP 3/4"-16UNF-2B

.562

1.305
.47" MIN. FULL 1.298
INSTALLATION: THD DEPTH
PLACE SEAL IN
BOTTOM OF PORT LOW PRESSURE
ACCESSORIES

ACCESSORIES
BEFORE INSTALLING
CARTRIDGE.

.125/.047 DIA.
Cartridge-Style Visual/Electrical Indicator HIGH PRESSURE
NOTE: TOP PORTION OF INDICATOR
DP05 Series .88
DIN 43650 Type A Male Plug (11MM)
PORT PARALLEL TO SAE-8
1NO, 1NC, & Common SPDT Switch (3 pole and ground)
5A; 125/250 VAC, 24 VDC (Resistive)
1.50 3000 PSI max Operating Pressure (6000 PSI for 80 PSID units)
Temperatures up to 200˚F
.88
Automatic Resetting
1.80
Factory Installed. Available as kit for field replacement.
RED
POP-UP
INDICATOR
1.50

1.80 30 mm

RED NC
POP-UP NO
INDICATOR C

30 mm

NC
NO
C
Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
71 72

FT SERIES BRV SERIES


FILTER TANK BACK PRESSURE INDUCING
ADAPTERS CHECK VALVES

Part Number A B C D
Male Thread Hose ID Barb Length Overall Length
FT0505ZP 1/2" NPT 1/2" 1.35" 3.44"
FT0507ZP 1/2" NPT 3/4" 1.35" 2.94"
FT0707ZP 3/4" NPT 3/4" 1.35" 3.12"
FT0710ZP 3/4" NPT 1" 1.35" 2.94"
FT1007ZP 1” NPT 3/4” 1.35” 4.12”
FT1010ZP 1" NPT 1" 1.35" 3.38"
FT1012ZP 1" NPT 1-1/4" 1.65" 3.44"
FT1212ZP 1 1/4" NPT 1-1/4" 1.65" 3.88"
FT1215ZP 1 1/4" NPT 1-1/2" 1.65" 3.58"
FT1515ZP 1 1/2" NPT 1-1/2" 1.75" 3.88"
FT1520ZP 1 1/2" NPT 2" 2.20" 4.50"
FT2015ZP 2” NPT 1-1/2” 1.75” 5.42”
FT2020ZP 2" NPT 2" 2.20" 4.50"
FT2025ZP 2" NPT 2-1/2" 2.40" 5.00"
FT2525ZP 2 1/2" NPT 2-1/2" 2.40" 5.50"
FT2520ZP 2 1/2" NPT 2" 2.20" 6.13"
FT2530ZP 2 1/2" NPT 3" 3.00" 6.13" Part Number A B C D E F (max) G
FT3030ZP 3" NPT 3" 3.00" 6.00" ZP suffix on fitting indicates
FT3025ZP 3" NPT 2-1/2" 2.40" 7.13" Zinc plated finish as standard. BRV07122XX* 3/4" NPTF 1 1/4" NPTF 1.50" .32" 1.10" 2.90" .81"

FT4040ZP 4" NPT 4" 3.80" 7.25" Black pipe finish is available.
BRV10152XX* 1" NPTF 1 1/2" NPTF 1.75" .32" 1.10" 4.04" 1.25"

HC SERIES
ACCESSORIES

BRV12202XX* 1 1/4" NPTF 2" NPTF 2.09" .30" 1.22" 4.36" 1.75"

HOSE CLAMPS
BRV20302XX* 2” NPTF 3” NPTF 3.06” .63” 1.78” 6.35” 2.50”

*Additional information required to place an order. Contact factory for assistance.

SEVERE SERVICE
"T" BOLT TYPE

VALVES
Hose Clamp Clamping Range Recommended Clamps
Part Number Min. Max Per Hose End
HC075 1.19" 1.37" One
HC100 1.38" 1.56" One
HC125 1.63" 1.88" One
HC138 1.81" 2.12" One
HC150 1.94" 2.19" One
HC187 2.19" 2.44" One
HC200 2.38" 2.69" One
HC238 2.81" 3.12" One
HC250 2.94" 3.25" Two
HC300 3.50" 3.81" Two
HC400 4.50" 4.81" Two

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
73 74

LRV SERIES RV SERIES


CHECK VALVES RETURN LINE TANK MOUNTED
CHECK VALVES
Heat Exchanger / Cross Port Relief Valves

Maximum Operating Pressure: 50 PSI


Standard Valve Setting: 1/2 PSI

100
LRV-07 and 10
90

80

70
Pressure Drop (PSI)

60
Part Numbers
50 LRV-07 and 10
500 PSI Max
40

30

20
Part Numbers Part Numbers
10 RV-07-1-01 & RV-10-1-01 RV-12-1-01 & RV-15-1-01

0
0 10 20 30 40 50
Flow (GPM)

Average Pressure Drop with 150 SUS Oil at 100˚ F.

80 FLOW
LRV-12 and 15 Part Numbers
LRV-12 and 15
70
500 PSI Max
VALVES

VALVES
60
Pressure Drop (PSI)

50

40 Part Number RV-30-1-01

6.31" 6.27" MAX. 7.00"


30 4.2" FLOW
A
Part Number
Inlet Port
20
5.55" RV07101 3/4" NPTF
RV10101 1" NPTF
10 A
A RV12101 1 1/4" NPTF
RV15101 1 1/2" NPTF
0 RV30101 3" NPTF
0 10 20 30 40 50 60 70
Part Number LRV-30
Flow (GPM) NOTE: Buna-N seals standard, Fluorocarbon seals optional
300 PSI Max

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
75 76

RCA SERIES RCB SERIES


RESERVOIR COVER RESERVOIR COVER

Integral Filler Breathers: Zinga SFB, FB or FTB Series Flows Up To: 96 GPM (Return) 32 GPM (Suction)
Suction/Return Port Coupling 3/8” to 1 1/4” NPTF Integral Filter Port Sizes: 7/8” - 14 UN (SAE-10) to
SAE-6 to SAE-20 1 7/8" - 12 UN (SAE - 24)
Buna - N Flat Gasket Integral Filler Breathers: Zinga SFB, FB or FTB Series
Temperature: Up to +250°F Suction/Return Port 3/8” to 1 1/4” NPTF
Application: Petroleum-based fluids only. Filter Operating Pressure: ­100 PSI Max.
Consult factory for synthetic fluid. Temperature: Up to +250°F
Application: Petroleum-based fluids only.
Consult factory for synthetic fluid.

Port Coupling Die-Cast Aluminum


(Suction / Return / Case Drain) Cover Construction

RCB-C Series Cover


Integral Spin-On Style Filler Breather
with Optional Pressure / Vacuum Relief Valve
(Order Spin-On Filter Seperately)
Buna-N Gasket

RCB-B Series Cover


Integral Filler Breather Top Port
with Optional Pressure / Vacuum Relief Valve R-Type Filter
RCA-A Series Cover RCA-B Series Cover RCA-C Series Cover
Steel Filler Breather Integral Filler Breather with Integral Spin-On Style Filler Breather with
(10 Micron Foam Element Std.)
(10 Micron Foam Element Std.) Optional Pressure / Vacuum Relief Valve Optional Pressure / Vacuum Relief Valve
(10 Micron Foam Element Std.) (Order Spin-On Filter Seperately)
RCB-A Series Cover Die Cast Aluminum
Steel Filler Breather Cover Construction
(10 Micron Foam Element Std.)
MAXIMUM TANK THRU HOLE Buna-N Gasket

8.46 "

SIZED FOR 3/8" BOLT HARDWARE

5.39" 4.33" Port Coupling 1/8" NPTF Gauge Port


.7 " (Suction / Return / Case Drain) (For use with Zinga Pressure/Vacuum
2.70 " Gauge or Switch)
6.5"
F-Type Filter

3.25" .55 "


MISC.

MISC.
Integral Tank Top
.5" Bottom Port
4.33 " Suction / Return Filter
(Add Drop Pipe w/ Zinga
8.66 " (Uses Zinga EE or RE Elements)
4.9" 3.1" Strainer or Diffuser)
9.21"
10.8"

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
77 78

MAXIMUM TANK THRU HOLE


12.25"
REFERENCE INFORMATION
3/8" BOLT HOLE CLEARANCE

10" 8.35" 7.63"


4"
6.55" Relative Size of Particles
5" 1.80"
Substance Size in microns (µ) Size in inches (in.)
1.68" Grain of Table Salt 100 0.00400
6.5" 5" 3.33" Human Hair 70 0.00270
15" 6.67" Lower Limit of Visibility 40 0.00158
10.00" White Blood Cells 25 0.00100
11.68" Talcum Powder 10 0.00040
Red Blood Cells 8 0.00030
Bacteria (avg.) 2 0.00008

SPIN-ON FILTER* 1 micron = 1 meters = 0.000004 inches


AE, AE-L, SE OR LE SERIES 1,000,000
FILTER ELEMENT

Measurement of Filter Efficiency


FILLER BREATHER BODY
WITH PRESSURE / VACUUM
VALVE ASSEMBLY ELEMENT HOUSING The measure of filter efficiency is determined by comparing the number of upstream particles (NU) of a deter-
(REMOVABLE FOR EASY mined size (x) vs. the downstream number (ND). This ratio is defined as the Beta Ratio (ßx).
ACCESS INTO RESERVOIR)

NU
ßx = where x = size of particles in microns (µ)
(FTB SHOWN) ND
OIL FILL PORT NU ND 1
Efficiencyx = 100 (1 - )
ßx

SUCTION
OR
RETURN
LINE

Example:
SUCTION STRAINER OR TANK DIFFUSER
ß Efficiency
37,500 Particles 10µ Upstream
(ORDER SEPARATELY) = 75.00 1.01 1.0 %
500 Particles 10µ Downstream 1.10 9.0 %
MISC.

* SPIN-ON FILTERS WITH ANTI-DRAIN BACK VALVES SHOULD NOT BE USED FOR BREATHER APPLICATIONS.
ZINGA STANDARD SPIN-ON FILTERS DO NOT HAVE ANTI-DRAIN BACK VALVES Beta Ratio: 1.50 33.3 %
2.00 50.0 %
ß10 = 75.00 Stated as “Beta 10 equal to 75” 10.00 90.0 %
75.00 95.5 %
Efficiency10 = 100 ( 1 - 1 ) = 98.7% 100.00 98.7 %

APPENDIX
75.00 200.00 99.5 %
1000.00 99.9 %

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
79 80

Typical ISO Cleanliness Level Range Numbers for System Components Zinga Filter Media Types

16 / 14 / 11 Servo Valves Z-Glass Media


Multi-Layered, non-woven glass media that provides the highest levels of depth filtra-
17 / 15 / 12 Proportional Control Valves tion efficiency and capacity. Higher capacity means longer service life. Coupled with a

Recommended Media
steel support mesh, Z-Glass can withstand higher differential pressures.
18 / 16 / 13 Vane & Piston Pumps/Motors
Directional & Pressure Control Valves

19 / 17 / 14 Gear Pumps/Motors

25µ Z-Glass

10µ Z-Glass

3µ Z-Glass
20 / 18 / 15 Flow Control Valves
Cylinders
New Unused Fluid Cellulose Media
Traditional paper based media that provides a nominal level of depth filtration and
capacity. Used with petroleum-based fluids only. Some grades of cellulose include a
18 / 16 / 13 ISO 4406 Code Range Numbers
layered glass fiber substrate to provide more efficiency.
Particles Larger than 14 micron (>14µc)
Particles Larger than 6 micron (>6µc)
Particles Larger than 4 micron (>4µc)

ISO 4406 RANGE NUMBERS


AquaZorb Media
Range Number Number of Particles Per ml
More Than Up to and including Water absorbing cellulose based media designed specifically to absorb and retain free
water from petroleum-based fluids. Commonly used in offline systems, AquaZorb will
24 80,000.00 160,000.00 operate until it is fully saturated and ultimately curtail flow through the media. A system
by-pass valve and service gauge is recommended when using AquaZorb.
23 40,000.00 80,000.00
22 20,000.00 40,000.00
21 10,000.00 20,000.00
20 5,000.00 10,000.00
19 2,500.00 5,000.00
18 1,300.00 2,500.00
Stainless Steel Mesh
17 640.00 1,300.00
Woven in a variety of precision patterns, stainless steel mesh provides a basic surface
16 320.00 640.00 type filtration with very low differential pressure. Applications include pump protection
15 160.00 320.00 and “last chance” valve protection. Stainless steel mesh can be serviced by ultrasonic
cleaning.
14 80.00 160.00
13 40.00 80.00
12 20.00 40.00
11 10.00 20.00 Mesh Degree of Filtration
10 5.00 10.00 30 560µ
60 280µ
9 2.50 5.00 100 141µ
8 1.30 2.50 200 75µ
APPENDIX

APPENDIX
7 0.64 1.30 200 x 1400 10µ
6 0.32 0.64

Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
81 82

Fluid Viscosity & Flow Capacity Guide Lines / Formulas / Conversions


In an effort to determine the flow capacity of filter it is important to consider the viscosity of the fluid being con-
ditioned. Pressure drop ( ∆P) produced by flow through a filter is directly proportional to the viscosity of the
fluid. At a set flow rate, a fluid with a lower viscosity will produce less pressure drop (and greater flow capacity)
than that of a fluid with higher viscosity.

Fluid Viscosity & Temperature


A fluid's viscosity is governed by its temperature. As a fluid's temperature increases, its viscosity decreases.
Fluid manufacturer’s viscosity charts should be used to determined the viscosity of the fluid at its normal oper-
ating temperature.

Estimating Pressure Drop (∆P)


All pressure drop data found in this catalog is based on 150 SUS oil. If the fluid to be filtered in your application
has a viscosity of 150 SUS and a specific gravity of 0.9 at the system’s normal operating temperature, the pres-
sure drop values can be taken directly off the graphs. For fluids that do not match, a quick estimate can be
determined by the following:

∆PEstimated = ∆PGraph x System Viscosity (SUS) x System Specific Gravity (SG)


150 .9

Diffusers & Suction Strainers


Using tank diffusers helps prevent air entrainment in hydraulic systems. With the proper placement of a baffle
between a diffuser and a suction strainer pump, cavitation can be curtailed. It is recommended to install
diffusers and strainers in the bottom 1/3 of the reservoir.
Filter Application Guidelines

Filter Type Max. ∆P at Normal Max. Line Velocity Filler Breathers


Operating Temperature (ft / sec ) Ingression of contaminants through the air can be reduced by using a breather with a filtration rating equal to or
better than the hydraulic system rating.
Suction Strainers 1” Hg (1/2 PSI) 5
Suction Line Filters ≤50% of max. allowed by 5 On systems with a fairly constant fluid level in the reservoir, a pressurized filler breather can increase the pump
pump manufacturer inlet pressure. Generally, the more pressure a pump has at its inlet, the quieter it will run.
Return Line Filters* ≤50% of filter by-pass valve 15
Pressure Filters ≤50% of filter by-pass valve 25 Useful Formulas & Conversions

* Return line filters should always include a by-pass valve. Flow intensification
should also be considered. .3208 x Flow Rate (GPM)
Pipe Velocity (fps) =
Internal Area (in2)

in3
RPM x Pump Displacement rev
Pump Outlet Flow (gpm) =
231

1 bar = 14.5 PSI 1 PSI = 2.04 in. Hg 1 ft H2O = .433 PSI

1 cm3 = 0.06102 in3 1 L = 61.0234 in3 1 gal (US) = 231 in3


APPENDIX

APPENDIX
Consult Manufacturer for Ordering Information Consult Manufacturer for Ordering Information

Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17 Phone 608.524.4200 Fax 608.524.4220 www.filtrationgroup.com E 17
APPENDIX
83

VELOCITY CHART FOR PIPE - TUBE - HOSE


STANDARD PIPE - SCHEDULE 40 EXTRA STRONG PIPE - XS - SCHEDULE 80

Pipe Int GPM GPM GPM GPM Int GPM GPM GPM GPM
OD ID ID
Size Area 5 Ft/Sec. 10 Ft/Sec.15 Ft/Sec.20 Ft/Sec. Area 5 Ft/Sec. 10 Ft/Sec.15 Ft/Sec.20 Ft/Sec.

Phone 608.524.4200
3/8" .675 .493 .191 3.0 6.0 9.0 12.0 .423 .141 2.2 4.4 6.6 8.8
1/2" .840 .622 .304 4.8 9.5 12.0 19.0 .546 .234 3.7 7.3 11.0 14.7
3/4" 1.050 .824 .533 8.4 16.7 25.1 33.4 .742 .433 6.8 13.6 20.3 27.1
1" 1.315 1.049 .864 13.5 27.0 40.6 54.1 .957 .719 11.3 22.5 33.8 45.0
1-1/4" 1.660 1.380 1.495 23.4 46.8 70.3 93.7 1.278 1.283 20.0 40.1 60.2 80.3

Fax 608.524.4220
1-1/2" 1.900 1.610 2.036 31.9 63.7 95.6 127.0 1.500 1.767 27.7 55.3 83.0 110.0
2" 2.375 2.067 3.356 52.5 105.0 157.0 210.0 1.939 2.953 46.2 92.5 139.0 185.0

Consult Manufacturer for Ordering Information


2-1/2" 2.875 2.469 4.788 75.0 150.0 225.0 300.0 2.323 4.238 66.4 133.0 199.0 265.0
3" 3.500 3.068 7.393 116.0 232.0 347.0 463.0 2.900 6.605 103.0 207.0 310.0 414.0
3-1/2" 4.000 3.548 9.886 155.0 310.0 465.0 619.0 3.364 8.888 139.0 278.0 418.0 557.0
4" 4.500 4.026 12.730 199.0 399.0 598.0 797.0 3.826 11.500 180.0 360.0 540.0 720.0

ASA TUBING SAE HOSE

www.filtrationgroup.com
Tube Wall Int GPM GPM GPM GPM GPM Hose Int GPM GPM GPM GPM
Size Thk. Area 5 Ft/Sec. 10 Ft/Sec.15 Ft/Sec.20 Ft/Sec.25 Ft/Sec. Size Area 5 Ft/Sec. 10 Ft/Sec.15 Ft/Sec.20 Ft/Sec.

E 17
3/8" .110 1.73 3.46 5.19 6.92
1/2" .083 .088 1.37 2.74 4.11 5.48 6.85 1/2" .196 3.08 6.15 9.23 12.30
5/8" .109 .133 2.08 4.16 6.24 8.32 10.40 5/8" .307 4.81 9.61 14.42 19.24
3/4" .442 6.90 13.80 20.70 27.60
3/4" .109 .222 3.48 6.96 10.44 13.92 17.40 7/8" .601 9.40 18.80 28.20 37.60
7/8" .095 .369 5.75 11.50 17.25 23.00 28.75 1" .785 12.30 24.60 36.90 49.20
1-1/4" 1.227 19.20 38.40 57.60 76.80
1" .109 .480 7.50 15.00 22.50 30.00 37.50
1-1/2" 1.767 27.70 55.40 83.10 110.80
1-1/8" .120 .615 9.60 19.20 28.80 38.40 48.00 2" 3.142 49.20 98.40 147.60 196.80
2-1/2" 4.909 77.00 154.00 231.00 308.00
1-1/4" .120 .801 12.55 25.10 37.66 50.20 62.75
3" 7.069 110.50 221.00 331.50 442.00
1-1/2" .120 1.247 19.55 39.10 58.65 78.20 97.75 3-1/2" 9.621 150.50 301.00 451.50 602.00
2" .250 1.767 27.70 55.40 83.10 110.80 138.50 4" 12.566 197.00 394.00 591.00 788.00
Options:
designers and users.

Features and Benefits:

• 1-micron air filter available


• Oil level indicating dipstick

Zinga.com
608.524.4200
PSI pressure all with .2 PSI vacuum
• Weld bases available in steel or aluminum
The RB2 Thread-Mount Nylon Filler Breather

30, 60, 100, or 200 stainless steel mesh liners


• Faster fill / refill rate for more efficient filtration

• Combined pressure / vacuum relief valve in 3, 5, or 10


• Steel baskets in 4”, 6”, 9”, or 12” nominal lengths with
• Engineered and tested for unparalleled splash resistance
weather durability for longer life in harsh and corrosive environments
For Performance You Can Count On

• Integrated splash-resistant design can be used with the pressure / vacuum option
The RB2 by Zinga Industries combines our time-tested breather design with an innovative

• Unique glass-filled nylon construction, provided in 1-1/4 and 2-1/2 thread sizes, means all-
economical reservoir mounting makes this splash-resistant design the right choice for reservoir
internal splash-resistant geometry. A variety of popular thread mounting options for simplified and
A Safer, Healthier and More Productive World
Filtration Group Corporation

As a part of Filtration Group, Zinga is a global leader in filtration for agriculture and construction
providing filtration and reservoir accessory product solutions for the mobile hydraulic market.
We lead the industry in developing extensive, award-winning product lines of filtration solutions
that improve oil cleanliness, maximize performance and meet warranty levels for reliability.

Phone 608.524.4200 Fax 608.524.4220


www.filtrationgroup.com

© 2017 All rights reserved.