309563 03
TR 635 top2
TR GB
TR 635 top2 6350100 0 6 12 18 24
TR 636 top2 6360100
Installation and MENU OK
operating instructions
Digital time switch
with weekly program
D GB F
I E NL
Connection of
different external
wires is permitted
TR 635 top2
Contents
Basic advice 3 Menu item OPTIONS
Screen and keys 4 PIN code setting 14
Operating instructions 4
Overview of menu selection 5 OBELISK top2 memory card 15
Connection/installation 6 Service address/Hotline 15
Initial start-up 8 Technical data 16
Reset 8
Menu item PROGRAM
Set switching time 9
Change/request switching time 11
Delete switching time 11
Pulse programming 12
Cycle programming 13
Menu item MANUAL
Manual and permanent switching 14
2
Basic safety instructions
GB
WARNING
Danger of death through electric shock or fire!
Installation should only be carried out by a qualified electrician!
• The device is intended for wall and front panel installation
• Corresponds to type 1 BSTU in accordance with IEC/EN 60730-2-7
• Power reserve (10 years) is reduced if memory card is inserted (in battery operation)
Designated use
• The time switch can be used for lighting, bell systems, ventilation etc.
• Only use in enclosed dry spaces
• Do not use on safety devices, e.g. escape route doors, fire safety equipment etc.
Disposal
Dispose of device separately in an environmentally sound manner
3
Screen display and keys Operating instructions
Programmed
1. Read text line
Date display Flashing text/symbol
switch times
C1 C2 C3 C4 represents query
Date display
Channel status
ON = On Days of the week from
ESC OK
OFF = Off 1 to 7
2. Make a decision
Display of active keys with
relevant function
bbbb
YES NO
Confirmation Alter/
MENU OK
change
– Activate screen – Store
– Open menu selection
Press OK Press
– Cancel menu – Confirm bbbb
– ESC selection
(leave menu) Selection options
are displayed
4
Overview of menu selection
GB
MENU
19 05 11 PROGRAM TIME/DATE MANUAL OPTIONS END
ON
9:40 46
NEW TIME PERMANENT OPERATING
ON HOURS
VIEW DATE PERMANENT LCD-ILLU-
OF MINATION
CHANGE SUMMER-- MANUAL ON LANGUAGE
WINTER
DELETE DAY OF THE TIMER PIN
WEEK
END DATE HOLIDAY FACTORY-
FORMAT SETTINGS
TIME RANDOM INFO
FORMAT
END END END
5
Connection
WARNING
Warning, danger of death through
electric shock!
Must be installed by qualified C1
electrician! 1 2 3 5 6
Disconnect power source. N
L
Cover or shield any adjacent live TR 635 top2 L
components.
Ensure device cannot be switched on!
Check power supply is disconnected.
Earth and bypass.
C1 C2
1 2 3 4 5 6 7 8
N
L
TR 636 top2 L
6
Installation
GB
Distributor installation (wall)
– for installation on DIN top
hat rails (in accordance with
EN 60715) with accessories
(9070071)
907 0 071
Front panel installation
– for installation in front frame
and transparent cover (in
accordance with DIN 43700)
7
Initial start-up DEUTSCH
RETAIN DELETE
PROGRAMS PROGRAMS
Set date, time and summer/ FORME
DATE
winter time rule
YEAR
MONTH
Press required key and display follows DAY
on screen (see figure). FORM TIME
ok
HOUR or
SU-WI GB/
IRL/P
19 05 11
ON
SU-WI FIN/ 9:40 46
RESET MINUTE
GR/TR
SU--WI SU-WI CDN
Press the 4 buttons simultaneously. EUROPE
SU-WI USA
You can choose between RETAIN SU-WI IRAN
PROGRAMS and DELETE PROGRAMS. SU-WI FREE
RULE
SO-WI FIX
DATE
NO SO-WI
8
PROGRAM
GB
Program switching time
Example: Switch on sports hall lighting from Mon–Fri, 7:30 to 12:00 hrs
Press MENU. PROGRAM is displayed.
Confirm by pressing OK. NEW is displayed.
Confirm by pressing OK. SWITCHING TIME is displayed.
Confirm by pressing OK. Select ON (for switch-on times).
Confirm by pressing OK. The display shows HOUR.
Use the + or – keys to enter hour, minute, (07:30) and confirm by pressing OK.
MONDAY is displayed.
Confirm by pressing OK. COPY is displayed.
Confirm by pressing OK. ADD TUESDAY is displayed.
Confirm by pressing OK and also confirm the days Wed, Thurs, Fri by pressing OK.
Continue with to SAVE is displayed. Confirm by pressing OK.
Repeat all steps for the switch-off time however instead of selecting ON with select OFF and
enter 12:00 for hour and minute.
9
MENU PROGRAM
NEW
SWITCH TIME PULSE CYCLE END
ON
HOUR
ON 7.30 MINUTE
MONDAY TUESDAY WEDNESDAY
COPY SAVE
ADD
TUESDAY
...
SAVE 84 memory locations are available.
10
Request/change/delete switching time
GB
Press MENU. PROGRAM is displayed. MENU
Confirm by pressing OK. NEW is PROGRAM
displayed.
NEW CHECK MODIFY DELETE
Use to select CHECK.
Confirm by pressing OK. SWITCH TIME
Confirm SWITCH TIME by pressing OK. MONDAY
The first of the entered switching times is NEXT MODIFY DELETE
displayed.
TUESDAY MODIFY HOUR MONDAY
Confirm by pressing OK. NEXT is displayed.
DELETE
MODIFY BLOCK
...
Change or delete individual switching times MINUTE
DELETED
MODIFY
Press to select MODIFY (or DELETE). BLOCK
Confirm MODIFY HOUR by pressing OK.
...
Confirm by pressing OK. The first of the entered switching
times is displayed.
Use the+ or – keys to enter hour and minute and confirm
by pressing OK.
11
Pulse time programming
Example: Switch on pause signal on Monday 8:05 hrs for 5 sec
Press MENU. PROGRAM is displayed.
Confirm by pressing OK. NEW is displayed.
Confirm by pressing OK. SWITCH TIME is displayed.
Select PULSE by pressing u.
Confirm by pressing OK. ON is displayed.
Confirm by pressing OK. The display shows HOUR.
Use the + or – keys to enter hour, minute, second (8:05) and confirm by pressing OK.
PULSE LENGTH is displayed.
Use the + or – keys to enter the duration of the pulse in minutes and seconds (5 sec).
MONDAY is displayed.
Confirm by pressing OK. COPY is displayed.
Press to select SAVE.
Confirm by pressing OK.
12
Cycle time programming
GB
In addition to switch-on and switch-off times (switching time) and short time pulses (pulse) cycle
times (cycle) can also be programmed. The pulse length (+ pulse pause) is limited to 17 hrs,
59 min, 59 sec
• Cycle times refers to cyclically repetitive time functions such as fan controls, urinal rinses etc.
Example: Switch on water rinsing Monday from 8:00 to 20:30 hrs every 15 min for 20 sec
(8:0000–8:0020 On; 8:1500–8:1520 On; 8:3000–8:3020 On etc.)
Cycle programming
– Start cycle: Monday 8:00 hrs
– Pulse length: 20 sec
– Pause length: 14 min 40 sec
– Cycle end: Monday 20:30:00 hrs
Observe the number of maximum electrical switching cycles when using the ‚cycle‘ function.
13
Manual and permanent Enter PIN code
switching
The PIN code can be set using the OPTIONS
Manual and permanent switching can be set
menu item (see fig.). If you forget the PIN call
using the menu in MANUAL or (in the auto-
the Theben hotline.
matic screen) by key combination (see fig.).
ok
OPTIONS
OPERATING PIN LANGUAGE
HOUR
Activate manual switching WITH PIN NO PIN
Briefly press both keys simultaneously.
CURRENT PIN
Activate permanent switching
NEW PIN
Simultaneously press both keys for 2 seconds.
00 00
Cancelling manual/permanent switching
Press both keys simultaneously.
14
OBELISK top2 memory card Serviceadresse/Hotline
GB
Use memory card Service address
Theben AG
Insert memory card in the time switch. Hohenbergstr. 32
72401 Haigerloch
Read / read out saved switching times and
GERMANY
device settings in the time switch or start Telephone +49 (0) 74 74 6 92 0
Obelisk program. Fax +49 (0) 74 74/6 92-150
Remove memory card OBELISK top2 Hotline
Telephone +49 (0) 74 74 6 92 -369
(No. 9070404) after copying. Fax +49 (0) 74 74/6 92-207
Avoid mechanical stress or dirtying with other hotline@theben.de
Addresses, telephone numbers etc.
storage/transport methods. www.theben.de
15
Technical data
• Operating voltage: 230–240 V~, +10 %/-15 % • Fluorescent lamp load: uncorrected +
• Frequency: 50–60 Hz (VVG) series corrected 1000 VA
• Power consumption: 0,8 W (TR 635 top2), parallel correction 400 VA (42µF)
0,9 W (TR 636 top2) • Compact fluorescent lamps: 90 W
• Standby: 0,9 W (TR 635 top2), • LED lamps: <2 W output, max. connec-
1,1 W (TR 636 top2) tion total of 20 W,
• Switch output: switching of choice of >2 W < 8 W output, max.
external wires is permitted connection total of 50 W
• Contact: two way switch • Permissible ambient temperature: –30 °C ... +55 °C
• Gap: <3 mm (µ) • Protection class: II in accordance with
• Contact material: AgSnO2 EN 60730-1 subject to
• Max switching capacity: TR 635 top2: designated installation
16 A, 250 V~, cos ϕ = 1 • Protection rating: IP 20 in accordance with
10 A, 250 V~, cos ϕ = 0,6 EN 60529
TR 636 top2: • Time accuracy: ≤ ±0,5 s/day at +20 °C
6 A, 250 V~, cos ϕ = 1 • Power reserve: 10 years (lithium call) at +25 °C
6 A, 250 V~, cos ϕ = 0,6 • Pollution degree: 2
• Min. switching capacity: 10 mA/230 V AC • Rated impulse withstand voltage: 4 kV
100 mA/12 V AC/DC • TR 635 top2: max. switching cycles with
• Incandescent lamp load + Halogen lamp load: 16 A resistive load: 50,000
2300 W (TR 635 top2) • TR 636 top2: max. switching cycles with
1200 W (TR 636 top2) 6 A resistive load: 50,000
16