HF 115 F -S MINIATURE HIGH POWER RELAY
Features
File No.:E134517 ● Special contact struction
● Incandescent lamp load: 3000W 230VAC
● 5kV dielectric strength (between coil and contacts)
V
D E ● Creepage distance: 11mm
● Low height: 15.7 mm
File No.:116934
● Meeting reinforce insulation
● Product in accordance to IEC 60335-1 available
● Plastic sealed and flux proofed types available
File No.:CQC17002168381
CONTACT DATA COIL
Contact arrangement 1A Coil power Approx. 400mW
Contact resistance 1) 100m max.(at 1A 6VDC)
Contact material W+AgSnO2 COIL DATA at 23
Resistive:16A 250VAC Pick-up Drop-out
Nominal Max. Coil
Incandescent Lamp: 3000W 230VAC Voltage Voltage Voltage
Contact rating Voltage Resistance
Inrush current: 165A / 20ms VDC VDC
VDC 1) VDC 2)
max.1) min.
LED(Electronic ballast): 492A/1.5ms
5 3.50 0.5 7.5 62 x (1 10%)
Max. switching voltage 440VAC
Max. switching current 16A 6 4.20 0.6 9.0 90 x (1 10%)
Max. switching power 4000VA 9 6.30 0.9 13.5 202 x (1 10%)
Mechanical endurance 5 x 106OPS
4
1.2 x 10 OPS (3000W 230VAC, 12 8.40 1.2 18 360 x (1 10%)
Electrical endurance Incand escentlamp load, Room temp.,
1s on 11s off) 18 12.6 1.8 27 810 x (1 10%)
Notes:1) The data shown above are initial values.
24 16.8 2.4 36 1440 x (1 10%)
CHARACTERISTICS
3)
Insulation resistance 1000M (at 500VDC) 48 33.6 4.8 72 5760 x (1 15%)
3)
Dielectric Between coil & contacts 5000VAC 1min 60 42.0 6.0 90 7500 x (1 15%)
strength Between open contacts 1250VAC 1min 3)
110 77.0 11.0 165 25200 x (1 15%)
Surge voltage (between coil & contacts) 10kV (1.2 / 50µs) Notes:1) The data shown above are initial values.
2) Maximum voltage refers to the maximum voltage which relay
Operate time (at rated. volt.) 10ms max. coil could endure in a short period of time.
3) For products with rated voltage ≥ 48V, measures should be
Release time (at rated. volt.) 5ms max. taken to prevent coil overvoltage in order to protect coil in test
and application (eg. Connect diodes in parallel).
Temperature rise (at rated. volt.) 55K max.
Functional 98m/s2
Shock resistance * SAFETY APPROVAL RATINGS
Destructive 980m/s2
VDE 16A 250VAC at 85°C
Vibration resistance * 10Hz to 150Hz 10g
16A 250VAC at 85°C
Humidity 5% to 85% RH Incandescent lamp 3000W 230VAC
TV-8 120VAC
Ambient temperature -40 to 85 Incandescent lamp 1200W 120VAC at 50°C
UL/CUL Incandescent lamp 1200W 277VAC at 50°C
Termination PCB Standard ballast 2.2A 277VAC at 50°C
Unit weight Approx. 13.5g Electronic ballast 16A 277/120VAC 85°C
Electronic ballast 12A 277/120VAC 85°C
Plastic sealed, Electronic ballast 8A 277/347VAC 85°C
Construction Flux proofed Electronic ballast 15A 120VAC 85°C3)
Notes:1) This contact resistance value is tested under the norminal Electronic ballast 8A 277/347VAC 85°C3)
voltage. Notes: 1) All values unspecified are at room temperature.
2) * Index is not that of relay length direction. 2) Only typical loads are listed above. Other load specifications
3) The data shown above are initial values. can be available upon request.
4) UL insulation system: Class F, Class B. 3) Zero crossing control cooperative.
HONGFA RELAY
ISO9001, IATF16949 , ISO14001, ISO45001, IECQ QC 080000, ISO/IEC 27001 CERTIFIED 2023 Rev. 2.00
213
ORDERING INFORMATION
H F 11 5F -S / 12 -H S F (XXX)
Type
Coil voltage 5, 6, 9, 12, 18, 24, 48, 60, 110VDC
Contact arrangement H: 1 Form A
Construction1) 2) S: Plastic sealed Nil: Flux proofed
Insulation Standard F: Class F Nil: Class B
Special code3) XXX: Customer special requirement Nil: Standard
Notes: 1) We recommend flux proofed types for a clean environment (free from contaminations like H2S, SO2, NO2, dust, etc.).
We suggest to choose plastic sealed types and validate it in real application for an unclean environment (with contaminations like H2S,
SO2, NO2, dust, etc.).
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays
on PCB.
3) The customer special requirement express as special code after evaluating by Hongfa. e.g.(335) stands for product in accordance to
IEC 60335-1 (GWT).
4) Two packing methods available: plastic tray package, tube package,Standard tube packing length is 616mm. Any special requirement
needed, please contact us for more details.
5) For products that should meet the explosion-proof requirements of "IEC 60079 series",please note [Ex] after the specification while placing
orders.Not all products have explosion-proof certification,so please contact us if necessary, in order to select the suitable products.
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT Unit: mm
Outline Dimensions
12.7 0.3
2x□0.5
0.5x0.8(4处)
PCB Layout Wiring Diagram
(Bottom view) (Bottom view)
2.6 5.04
① ⑥ ⑤
② ③ ④
6x 1.3 20.16
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
3) The width of the gridding is 2.52mm.
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the
user’s responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
214
12.7 0.3