0% found this document useful (0 votes)
66 views1 page

3bed 1

The document outlines architectural plans for a proposed main house, including details on precast concrete cappings on brick parapets and galvanized iron (g.i.) flashing. It includes various elevations, sections, and notes on construction materials and methods. The design emphasizes compliance with municipal regulations and specifies structural elements such as roof pitch, ceiling details, and drainage systems.

Uploaded by

muzuluser
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views1 page

3bed 1

The document outlines architectural plans for a proposed main house, including details on precast concrete cappings on brick parapets and galvanized iron (g.i.) flashing. It includes various elevations, sections, and notes on construction materials and methods. The design emphasizes compliance with municipal regulations and specifies structural elements such as roof pitch, ceiling details, and drainage systems.

Uploaded by

muzuluser
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

g.

i flashing
precasted concrete cappings on brick paraperts
precasted concrete cappings on brick paraperts
g.i flashing
g.i flashing
g.i flashing g.i flashing

STD# 397
40000

6000 20629 13376

NE11
NC11F NC1 NC1 NC2F NC2F
ND11F ND11F
110 dia 110 dia
NGL G marley G marley G
NGL NGL NGL
I.L 450 min ramp 1:12
100mm dia gew pipe laid @ 1:40 fall to septic tank

8480
SOUTH ELEVATION 1:100 WEST ELEVATION 1:100

precasted concrete cappings on brick paraperts g.i flashing

MAIN HOUSE
precasted concrete cappings on brick paraperts g.i flashing

25000

PROPOSED

STD# 395
g.i flashing

STD# 398
ROAD
g.i flashing

13520
800
g.i flashing

3000
NC2F NC4F
ND11F ND11F ND11F ND11F ND11F ND11F

NGL NGL NGL NGL


STD# 399
NORTH ELEVATION 1:100 EAST ELEVATION 1:100
SITE PLAN 1:200

precasted concrete cappings on brick paraperts


ROOF NOTES

-Interlocking conc tiles on 38x38sw batterns on


trusses by specialist at 1200 centres on
114x38sw wallplate firmly secured on brickwall.
N
-228x19 fascia board.
-Roof pitch 25°. GENERAL NOTES:
g.i flashing -g.i flashing to all wall-roof junctions
230 230 115 CEILING NOTES g.i flashing
-provide brick-force after every 3rd course below slab level DRAUGHTSMAN 012
2085 4670 3730 3645 5320 and after every 4 to 5 courses thereafter.
600 -12mm plaster board ceiling on38x38sw brandering
-20mm wood float finished sand cement wall plaster on
1255 5500 3500 3645 4860 at 300 centres on tie beam.
common brick walls.
600 -75x50sw coved cornice.
230 230 230 230 230 -3 coats of paint on plastered walls.
115 -trape door to measusre 750x750
-100mm dia pvc gutter on 75mm dia down pipe. CELL: 0772 557 188
- provide at least 2 air bricks above each opening.
ND11F ND11F ND11F wall plate wall plate
SEGMENTAL ARCH TO EGINEER`S DESIGN W - 75x75 gutter with a down pipe of 75x100.
230
230

230

r.c lintel r.c lintel r.c lintel


230

ab ab
460

ab ab
r.c lintel
ab ab
-provide concrete shoe (dripstone) underneath every down

PASSAGE
pipe.
1354
1124

2800
D22F NC1
-at least two air bricks above each opening.
V E R A N D A H
1819

2100
ND11F ND11F
Lounge 500 BEDROOM 2 LUE -all work on site to comply with the given plan and municipal
4m ALUMINIUM SLIDING DOOR

cill
230
230

ab ab ab ab
cill
ab

grano
regulations.
dpc
NGL NGL -any querries or adjustment on this plan refer back to the
230

c
3879

4799

DRAWING TITLE:
1750
ND11F

designer.
4969

i
900

Bedroom 2
SEGMENTAL ARCH TO EGINEER`S DESIGN

-all walls enclosing carpot to be built up to undersurface of


b

800
Bedroom 3 grano
Master Bedroom
6399

the roof.
230

3615

230
115

grano grano
grano

PROPOSED MAIN HSE TO BE


ab

c
700 700 500 500 700
1790

1750

i
115 1000
135

230
BUILT
460

b
ab

1433 600 556 556 600 -30mm grano sand cement screed on
ARCH OVER
-100mm concrete slab on
830

ON STAND NUMBER 398


230

230
230
230

FLD

-150mm well compacted hardcore


1600

ab
ARCH OVER

Dressing
11

P a s s a g e
c
dress table

1500
1200

1200

1200

ELMESWOOD
74
1000

SECTION W-W 1:100


i
area
1815
NC4F

grano
1433
13 319

ARCH OVER ARCH OVER


b
460

115
11

MARONDERA.
230

grano
230

230

32

linen linen
600

SEGMENTAL ARCH TO EGINEER`S DESIGN


13 5°
115
ab

115 115
ab

485
shower

Bath
ND11F

13
17
ARCH OVER


Dining
Pantry
3000

3000

1200

18

FLD
grano

1485 830 grano

Lue Study
3115
shower

2500

grano

Kitchen Ensuite
348
h/w/b

OWNER
5427
ab

3115

ceramic tiles ceramic tiles


ceramic tiles
tub 400x600 cast iron lead on
230

W/C
W/C
100mm reinforced concrete slab.
6460

Ms E MUGOCHA
earth filling
1:12 GARAGE RAMP GRADIENT

tub h/w/b
iron sheet supported on edge of trench
250
230
230
1 HR FIRE RATED DOOR

ab ab ab ab ab ab ab ab ab ab
inlet outlet
650
LAZYMAN DOOR

ab

NC1 NC1 NC2F ND11F NC2F


1712

rw
NC2F

2058

20mmwater proofed
3000

cement sand render (1:3).


1258

1175
2630
ab

tank to have a fall of 1:20

DATE
230
230

ab ab W
230

230
918

Single Garage
1148

NC11F
233
grano
1797
SECTION S-S 1:100 13-7-2013
230
230

rw
ab ab

NE11 115 230


3000 1700 2815 4860
230

230 230 230 230 115 230 230 Designed by:


1500

1200

115 115
6500 3500 1200 1000 1700 2600 2145
S
489
Z.ZENGENI
230

230 115 230 230


20629
230 230 3000 5000
2500

Drawn by:
Z.ZENGENI
SEPTIC TANK AND SOAKAWAY DETAIL
1:100 ROOF PLAN 1:200
FLOOR PLAN 1:100 FLOOR AREA =241,05m² scale:
As shown

GSPublisherVersion 0.20.100.100

You might also like