0% found this document useful (0 votes)
23 views52 pages

Manual

The VCL-TP Teleprotection Equipment User Manual outlines the product's warranty, limitations, and exclusive remedies, emphasizing the importance of proper maintenance and authorized personnel for repairs. It details the equipment's features, technical specifications, and user programmability, including various transmission options and safety warnings. The manual also includes information on installation, management, and monitoring, ensuring compliance with relevant standards and providing a comprehensive overview of the product's capabilities.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views52 pages

Manual

The VCL-TP Teleprotection Equipment User Manual outlines the product's warranty, limitations, and exclusive remedies, emphasizing the importance of proper maintenance and authorized personnel for repairs. It details the equipment's features, technical specifications, and user programmability, including various transmission options and safety warnings. The manual also includes information on installation, management, and monitoring, ensuring compliance with relevant standards and providing a comprehensive overview of the product's capabilities.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 52

VALIANT

COMMUNICATIONS

VCL-TP Teleprotection Equipment


E1 Plus E1 and E1 Plus C37.94

User Manual
Teleprotection Equipment Notice

Warranty

This Valiant product is warranted against defects in material and workmanship for a period of
one year from the date of shipment. During the warranty period, Valiant will, at its discretion,
either repair or replace products, which prove to be defective. For warranty service or repair,
this product must be returned to a service facility designated by Valiant. The buyer shall
prepay shipping charges to Valiant and the company shall pay shipping charges to return the
product to the buyer. However, the buyer shall pay all the shipping charges, duties and taxes
for products returned to Valiant from another country.

Limitation of Warranty

The foregoing warranty shall not apply to defects resulting from improper or inadequate
maintenance by the buyer. The buyer-supplied firmware or interfacing, unauthorized
modification or misuse, operation outside of the environmental specifications for the product
or improper site preparation or maintenance.

Exclusive Remedies

The remedies provided herein are the buyer's sole and exclusive remedies. Valiant shall not
be liable for any direct, indirect, special, incidental or consequential damages, whether based
on contract or any legal theory.

Notice

This manual contains information that is proprietary to Valiant Communications Limited. No


part of this publication may be reproduced in any form whatsoever without prior written
approval by Valiant Communications Limited.

Safety Warnings

!
The exclamation point within a triangle is intended to warn the operator or
service personnel of operation and maintenance factors relating to the product
and its operating environment, which could pose a safety hazard.

Always observe standard safety precautions during installation, operation and maintenance
of this product. Only qualified and authorized service personnel should carry out adjustment,
maintenance or repairs to this instrument. No adjustment, maintenance or repairs should be
performed by either the operator or the user.

UALITY ASSURANCE PROGRAM


Valiant’s products are designed and manufactured under a strict Quality Assurance
Program based on the ISO 9001:2015, ISO 10001: 2007, ISO 14001: 2015 and ISO
18001:2007 philosophy and principles. Valiant pays very special attention to its
vendor development program which ensures an “end-product” of the highest
quality at the most cost effective prices.

Valiant Communications 2
Teleprotection Equipment Index

Index

Particulars P. No.
Section 1: Product Description 6
Product Overview 7
Features and Benefits 8
Performance 8
Flexibility and User Programmability 8
Maintenance 9
Event and Alarm Logging 9
Management and Monitoring 9
Reliability 9
Error Detection and Coding 9
Time Clock 9
Application Diagram 10

Section 2: Technical Specification 11


2.048Mbps, G.703 E1 Interface 12
Optical Fiber Interface - Option 1 12
Optical Fiber Interface - Option 2 12
Optical Fiber Interface - Option 3 13
IRIG-B Time Synchronization Port 13
Command Voltage Options 13
Teleprotection Commands 13
Transmission Standards and Compliance 14
Teleprotection Standards and Compliance 14
Power Supply Options 14
Power Consumption 14
EMI, EMC, Surge Withstand and other Compliances 15
Environmental 15
Electromagnetic Standard Compliance 15
Compliance Regulatory 15
Dimensions 16

Section 3: Panel Description and Connection Details 17


Front View 18
Front View Details 18
Front Panel Details 20
Rear View Description 21
Rear Panel Description 23
OAM Port Connection 24
COM Port Connection 25
USB Port Connection 25
DC Input Connection 26
E1 Interface Connection 27

Valiant Communications 3
Teleprotection Equipment Index

Index

Particulars P. No.
Optical C37.94 Interface (SFP) Connection 28
IRIG-B Connection 28
Command Selection Settings 29

Section 4: HyperTerminal Settings 31


To use HyperTerminal for executing the CLI commands 32
HyperTerminal settings for COM Port (RS232) and USB Port 33
HyperTerminal settings for 10/100BaseT Management Port 39
Telnet without using HyperTerminal utility 45

Section 5: Flow Chart for Installation 46


Flow Chart for Installation 47

Section 6: Ordering Information 48


CORE UNIT without Network Interface and PSUs 49
Add IRIG-B Time Synchronization option 49
Add Network Interface 50
Specify Command Voltage 50
Add Power Supply Option 50
Select SFP Option 51
Add Trip Counter Display 51
Add VCL-TP external feed-through terminal block panel 52
Support 52

CAUTION
ELECTROSTATIC
SENSITIVE
DEVICES

DO NOT OPEN OR HANDLE


EXCEPT AT A
STATIC-FREE WORKSTATION

Valiant Communications 4
Teleprotection Equipment Index

n k .
bla
a l ly
t ion
te n
f t in
is le
ag e
i s p
T h

Valiant Communications 5
Teleprotection Equipment Section 1

SECTION: 1

Product Description

Valiant Communications 6
Teleprotection Equipment Product Overview

Product Overview

Teleprotection Equipment is an extremely reliable


and flexible product that is available with 1+1
Optical Link Redundancy (C37.94), 1+1 Power
Supply and 8/16, Digital Trip Counter Display Panel
with 8 user configurable External Relay Alarm
output options.

Teleprotection equipment may be used independently, in a standalone point-to-point application, or as


an integral extension of the VCL-MX Version 6, E1 Voice and Data Multiplexer solution to provide
Teleprotection over SDH or PDH data networks.

Teleprotection equipment is extremely reliable and flexible product that offers up to 8, two-way
independent command channels, operated selectively or simultaneously over a wide choice and a
variety of transmission interfaces.

The “Trip Counter Display” shows the total


number of “Trip Input / Trip Receive” and “Trip
Output / Trip Send” commands on each of the 8
Teleprotection channels, individually. A manual
display counter reset option is also provided which
may be enabled or disabled by the system
administrator.

Trip Counter Display and Alarm Extension Unit is designed as an optional extension of the
Teleprotection Equipment to provide 8 Channel, Digital Trip Counter Display along with 8 External
Relay Alarm outputs.

The Trip Counter Display and Alarm Extension Unit may be either powered from the Teleprotection
Equipment, or directly from a 48V DC, 110V DC, 220V DC or 250V DC power source. 1+1 Redundant
Power is also offered as an option.

Transmission interface options include:


! 8 Binary Commands over E1, 2.048Mbps link
! 8 Binary Commands over Redundant, 1+1 E1 (2.048Mbps) transmission links with path
protection / route protection and automatic failover
! 4+4 Binary Commands over dual E1 (2.048Mbps) transmission links in a point-to-
multipoint application
! 8 Binary Commands over IEEE C37.94 Optical link
! 8 Binary Commands over Redundant, 1+1 IEEE C37.94 Optical transmission links with
path protection / route protection and automatic failover
! 4+4 Binary Commands over dual IEEE C37.94 Optical transmission links in a point-to-
multipoint application
! 8 Binary Commands over E1 plus IEEE C37.94 Optical, 1+1 redundant transmission
links with path protection / route protection with automatic failover.

Valiant Communications 7
Teleprotection Equipment Features and Highlights

Features and Benefits

Compact, standard 19-Inch Rack-mountable, 2U high chassis


Unrivaled Speed, Security and Reliability
Distance teleprotection applications
User programmable for Direct Tripping, Permissive Tripping and Blocking Protection Schemes
Compliant with IEC 60834-1 and IEC 834-1 specifications and standards for reliability
Optical Interface fully compliant with IEEE C37.94 for error resistant transmission
Use in a Standalone, Point-To-Point application
Use as an integrated part of the VCL-MX Version 6 E1 Voice & Data Multiplexer solution over an
SDH or PDH data network.
Option of 1+1 Route / Path Protection for C37.94 Optical interface with less than 5ms link
recovery in a point-to-point protected link.
Bi-directional Transmission of 8 command Inputs and 8 command outputs
Automatic loop test facility
IRIG-B time synchronization option to synchronize time-stamps with GPS.
IEEE-1588v2 time synchronization option to synchronize time-stamps with PTP Grandmaster.
Available with Trip Digital Display Counters (8/16)
Full Duplex Operation
Available with 48V DC, 110V DC, 220V DC and 250V DC command and switching voltage
options
Option of 1+1, Redundant Power Supply
Available with 24V DC, 48V DC, 110V DC, 220V DC and 250V DC power supply options
IEEE C37.94 compliant Multi-Mode optical link interface option for short reach optical links
IEEE C37.94 compliant (modulation only) Single Mode optical link interface option for long reach
optical links (< 40 KM, < 80 KM, < 120 KM, < 150 KM)
2.048Mbps, G.703 interface option for transmission over 4-wire electrical links
Immunity to Voltage Dips, Short Power Supply Interruptions and Voltage Variations as per
IEC 61000-4-11 specifications.

Performance
Less than 2ms command transfer time
Less than 4ms relay operating time
Less than 5ms back-to-back operating time (including relay operating time) in IEEE C37.94
Optical mode
Less than 5ms back-to-back operating time (including relay operating time) over IP/MPLS
Interface
Less than 5ms back-to-back operating time (including relay operating time) in 2.048Mbps,
E1 interface mode

Flexibility and User Programmability

User programmable parameters for “Input” command sampling time and “Output” command holding
time:

User programmable command holding delay for error resistant command inputs
User programmable command sampling rate for error resistant command transmission

Valiant Communications 8
Teleprotection Equipment Management and Monitoring

Maintenance

Manual Loop Test: This feature initiates a “Manual Loop-Test” of the transmission link that
interconnects the “Local” Teleprotection Terminal and the “Remote” Teleprotection Terminal
Automatic Loop Test: The Automatic Link Test feature automatically initiates “Periodic Loop
Tests” at user programmed intervals of the transmission link that interconnects the “Local”
Teleprotection Terminal and the “Remote” Teleprotection Terminal.

Event and Alarm Logging

Time-Stamped Alarm Logging


Time-Stamped Event Logging
IRIG-B time synchronization option to synchronize time-stamps with GPS.
NTP time synchronization option to synchronize time-stamps with NTP Server.
IEEE-1588v2 time synchronization option to synchronize time-stamps with PTP
Grandmaster.

Management and Monitoring

RS232 serial, USB serial interfaces for local terminal access


10/100BaseT Ethernet Interface for remote access over an IP network
Encrypted Password Protection
Telnet – Remote access over IP links
SSH – Secured remote access using Secure Shell Protocol over IP links
Automatic Link Test feature link testing at user programmable periodical intervals
Visual I/O status LED Display.
Dry contact external alarm relay to connect an external alarm on an annunciator panel, which
can be wired up for either NO or NC condition.

Reliability

Advanced Communication Protocols to ensure reliable transmission of commands


Power Supply Immunity to withstand impulse surges and transients of upto 10,000 Volts
High Quality Relays withstands voltage 10 kV between coil and contacts (1.2 x 50 μs)
2.5kV RMS - Contact Input / Output Hi-port dielectric strength
Maximum Switching Voltage: 400V AC or 300V DC
Optoisolated Command Inputs
Optoisolated Relay Outputs
Relays – Mechanical: 10,000,000 operations min. (at 18,000 operations/hour).

Error Detection and Coding

Line Code Violation Detection


LOS Detection
Block Command Encoding as per C37.94.

Time Clock

Synchronization with an external IRIG-B Input from GPS.

Valiant Communications 9
Teleprotection Equipment Application Diagrams

Application Diagram
High Voltage Line

Trip Trip

IEC-61850 IEC-61850
Distance / Distance /
Differential Differential
Protection Protection
Relay Relay
<

<
Contact I/O 8 8 8 8 Contact I/O
IEEE C37.94 - 2 Optical Fiber
<

<
VCL-TP VCL-TP
< Less than 5 ms + Network Delay >
Teleprotection < < Teleprotection
1 KM to < 180 KMS

Figure #1 - Typical Point-To-Point Application

High Voltage Line


Substation A Substation B

Optical Fiber

E1 E1

VCL-TP E1 MUX / E1 MUX / VCL-TP


Teleprotection PDH / SDH PDH / SDH Teleprotection

IEC-61850 IEC-61850
Teleprotection System
Distance / <
< Distance /
Differential Line Protection System Differential
Protection Relay Protection Relay

Figure # 2 Typical Application over a IEEE C37.94 compliant optical link, as an integrated
part of the VCL-MX V6 E1 voice and data multiplexer solution over an SDH or PDH data network.

SDH or PDH
Network

E1 Interface E1 Interface

SDH / SDH /
PDH MUX PDH MUX

VCL-TP IEEE C37.94 - 2 Optical Fiber VCL-TP


Teleprotection Teleprotection
<
<

8 8 8 8
<

<

Contact I/O < < Less than 5 ms + Network Delay > Contact I/O
<

Figure # 3 - Typical Application over an IEEE C37.94 Optical Channel,


or E1 interface, or as an integrated part of the E1 PDH Voice & Data Multiplexer
solution over an SDH or PDH data network

Valiant Communications 10
Teleprotection Equipment Section 2

SECTION: 2

Technical Specifications

Valiant Communications 11
Teleprotection Equipment Technical Specifications

Technical Specifications:

2.048Mbps, G.703 E1 Interface

Number of Interfaces 1
Conformity (Electrical) G.703 (E1)
Frame Structure As per ITU (CCITT) G.704
PCM Sampling Rate 8000 Samples/sec
Bit Rate 2048 Kbps ± 50 ppm
Code HDB3
Nominal Impedance 75 Ohms unbalanced / 120 Ohms balanced
Peak Voltage of a mark for balanced 2.37 V ± 0.237 V (75 Ohms unbalanced)
75 / 120 Ohms interface 3.0 V ± 0.3 V (120 Ohms balanced)
Nominal Pulse Width 244 ns
Pulse Mask As per ITU (CCITT) Rec. G.703
Output Jitter < 0.05 UI (in the frequency range of 20Hz to 100
KHz)
Permissible Attenuation 6 dB at 1 MHz
Return Loss at:
51.2 KHz to 102.4 KHz > 12dB
102.4 KHz to 2048 KHz > 18dB
2048 KHz to 3072 KHz > 14dB
Jitter Tolerance As per ITU (CCITT) G.823
Loss and Recovery of Frame Alignment As per Clause 3 of ITU (CCITT) G.732
Connector Type RJ45 (F) - 120 Ohms
BNC(F) - 75 Ohms

Optical Fiber Interface - Option 1:

Optical Module Type Connector Fiber Distance Type IEEE 37.94


SFP LC Multimode < 500 m Laser Fully Compliant
850 nm < 2 KM
1310 nm

Optical Fiber Interface - Option 2:

Optical Module Type Connector Fiber Distance Type IEEE 37.94


1x9 ST Multimode < 2 KM LED Fully Compliant

Valiant Communications 12
Teleprotection Equipment Technical Specifications

Optical Fiber Interface - Option 3:

Optical Module Type Connector Fiber Distance Type IEEE 37.94


SFP LC Single-mode < 40 KM Laser Modulation Only
1310 nm < 80 KM
1550 nm < 120 KM
< 150 KM

IRIG-B Time Synchronization Port

Connector BNC
Impedance 50 Ohms

Command Voltage Options

48V DC 110V DC 220V DC 250V DC

Teleprotection Commands: Number of Commands

Number of Input Commands 8 Type - Binary


Number of Output Commands 8 Type - Potential Free

Current Consumption: <10mA input current

Command Operating Thresholds

Command Input (Sense) On Input (Sense) Off


48V DC 41-72V DC <25V DC
110V DC 90-140V DC <60V DC
220V DC 180-290V DC < 140V DC
250V DC 210-290V DC <140V DC

Valiant Communications 13
Teleprotection Equipment Technical Specifications

Output

Relay withstands 10 kV between coil and contacts @1.2 x 50 μs


2.5kV RMS - Contact Input / Output Hi-port dielectric strength
Maximum Switching Voltage: 400V AC or 300V DC
Optoisolated Relay Outputs
Relays - Mechanical: 10,000,000 operations min. (at 18,000 operations/hour).

Input / Output Command Combination Options

off When all 8 inputs are independent


and When two adjacent inputs are used logically, “and-ed”
or When two adjacent inputs are used logically, “or-ed”
log When two inputs are used in a combination
In-a In-b Out
0 1 0
1 0 1
1 1 Previous
0 0 Previous

Transmission Standards and Compliance

! Electrical: ITU-T, G.703 for 2.048Mbps interface


! Optical: IEEE 37.94 compliant Multi-Mode optical interface
! Optical: IEEE 37.94 compliant modulation 1310nm Single-Mode optical interface
! Laser: Class I (for Single-Mode Optical Interface) – Eye-safe as per EN 60825-1 specifications.

Teleprotection Standards and Compliance

! Compliant with IEC 60834-1 and IEC 834-1 specifications and standards.

Power Supply Options

24V DC.
48V DC.
110V DC / 125VDC
220V DC / 250V DC
Voltage Withstand: Meets and exceeds IEC 834-1 and IEC 255 requirements.

Power Consumption

< 15 Watts.

Valiant Communications 14
Teleprotection Equipment Technical Specifications

EMI, EMC, Surge Withstand and other Compliances

EN 50081-2 EN 50082-2 IEC 60068-2-29


IEC 61000-4-6 (Conducted Immunity). IEC 60068-2-6 IEC 60068-2-2
IEC 60068-2-78 IEC 60068-2-1 IEC 60068-2-14
CISPR 22 / EN55022 Class B (Conducted Emission and Radiated Emission)
IS 9000 (Part II Sec. 1-4, Part III Sec. 1-5, Part IV, Part 14 Sec. 1-3)
IEC 60870-2-1 IEC 61000-4-5 IEC 61000-4-12
IEC 61000-4-3 (Radiated Immunity) IEC 61000-4-8 IEC 61000-4-16
IEC 61000-4-2 IEC 61000-4-10 Telcordia GR-1089 Surge
IEC 61000-4-4 IEC 61000-4-11 and Power Contact

! ESD, Voltage and Surge Withstand: Meets and exceeds IEC 61000-4-2, IEC 61000-4-4,
IEC 61000-4-5, Level 4 specifications
! Immunity to Voltage Dips, Short Power Supply Interruptions and Voltage Variations meets and
exceeds IEC 61000-4-11, Level 1 specifications.

Environmental

0 0
Operating Temperature -20 C to +60 C
Maximum Operating Humidity 95% R.H., Non-Condensing
Maximum Operating Altitude Up to 3,000 meters above sea level
Operation Complies with ETS 300 019 Class 3.2
Storage Temperature -400C to +700C
Storage Complies with ETS 300 019 Class 1.2
Maximum Storage Humidity 98% R.H., Non-Condensing
Maximum Storage Altitude Up to 3,000 meters above sea level
Transportation Complies with ETS 300 019 Class 2.3

Electromagnetic Standards Compliance

! EN 50081-2
! EN 50082-2
! IEC 61000-6-2 (immunity)
! IEC 610000-6-4 (emission)

Compliance / Regulatory

! CE Compliant / CE Marked
! Complies to IEEE and IEC standards
! Complies with FCC Part 68 and EMC FCC Part 15 and CISPR 22 Class B
! Operation ETS 300 019 Class 3.2
! Storage ETS 300 019 Class 1.2
! Transportation ETS 300 019 Class 2.3

Valiant Communications 15
Teleprotection Equipment Technical Specifications

Dimensions - Teleprotection Unit

Rack mounting Standard 19-Inch. DIN Rack


Height 85.00 mm. Standard 2U high
Depth 300.00 mm.
Width 477.00 mm.
Weight 4.00 kg

Dimensions - Trip Counter Display

Rack mounting Standard 19-Inch. DIN Rack


Height 85.00 mm. Standard 2U high
Depth 240.00 mm.
Width 477.00 mm.
Weight 4.00 kg

Valiant Communications 16
Teleprotection Equipment Section 3

SECTION: 3

Panel Description and Connection Details

Valiant Communications 17
Teleprotection Equipment Connection Details

Front View

VCL-TP Teleprotection - E1 Plus C37.94

VCL-TP
INPUTS OUTPUTS

L1 L5 L1 L5

L2

L3
L6

L7
L2

L3
L6

L7
TELEPROTECTION - E1 Plus C37.94
L4 L8 L4 L8

LOOP LOOP
E1 OPT TEST TEST PSU 1 PSU 2 LOOP
SYNC SYNC PASS FAIL TEST USB COM

VALIANT
10/100BaseT
COMMUNICATIONS
MGMT

Front View Details - VCL-TP Teleprotection - E1 Plus C37.94

Input Output
LEDs LEDs

VCL-TP
INPUTS OUTPUTS

L1 L5 L1 L5

L2

L3
L6

L7
L2

L3
L6

L7
TELEPROTECTION - E1 Plus C37.94
L4 L8 L4 L8

LOOP LOOP
E1 OPT TEST TEST PSU 1 PSU 2 LOOP
SYNC SYNC PASS FAIL TEST USB COM

VALIANT
10/100BaseT
COMMUNICATIONS
MGMT

PSU 2
Loop Management COM
Test Port Port
Pass
PSU 1 USB
Port
OPT Loop Loop
Sync. Test Test
Fail
E1
Sync.

Valiant Communications 18
Teleprotection Equipment Connection Details

Front View

VCL-TP Teleprotection - E1 Plus E1

VCL-TP
INPUTS OUTPUTS

L1 L5 L1 L5

L2

L3
L6

L7
L2

L3
L6

L7
TELEPROTECTION - E1 Plus E1
L4 L8 L4 L8

LOOP LOOP
E1-A E1-B TEST TEST PSU 1 PSU 2 LOOP
SYNC SYNC PASS FAIL TEST USB COM

VALIANT
10/100BaseT
COMMUNICATIONS
MGMT

Front View Details - VCL-TP Teleprotection - E1 Plus E1

Input Output
LEDs LEDs

VCL-TP
INPUTS OUTPUTS

L1 L5 L1 L5

L2

L3
L6

L7
L2

L3
L6

L7 TELEPROTECTION - E1 Plus E1
L4 L8 L4 L8

LOOP LOOP
E1-A E1-B TEST TEST PSU 1 PSU 2 LOOP
SYNC SYNC PASS FAIL TEST USB COM

VALIANT
10/100BaseT
COMMUNICATIONS
MGMT

PSU 2
Loop Management COM
Test Port Port
Pass
PSU 1 USB
Port
E1-B Loop Loop
Sync. Test Test
Fail
E1-A
Sync.

Valiant Communications 19
Teleprotection Equipment Connection Details

Front Panel Details of Teleprotection

S. No. Front Description Remarks


Indication Reference
1 LOOP TEST LOOP TEST SWITCH On pressing Loop Test Switch, Loop Test Pass
LED should illuminate. When you release the
button, Loop Test Pass LED should extinguish
and the remainder will return to indicating the
current communication status.
2 INPUT 1 ~ 8 Orange LED INPUT COMMAND LEDS:
The corresponding LED will be “ON” when
defined voltage level present on corresponding
INPUT (SENSE) channel.
3 OUTPUT Orange LED OUTPUT SWITCHING LEDS:
1~8 The corresponding LED will be “ON” when
relay contact is activated on corresponding
output channel, i.e TRIP Command is present.
4 MGMT PORT RJ-45 Ethernet Port Ethernet Management Port.
5 COM PORT DB9 (RS232 Port) Serial RS232 Management Port
6 USB PORT USB PORT Serial USB Management Port
7 E1-A SYNC. Green LED E1 Port-A Link connected, LED will be “ON”
8 E1-B SYNC. Green LED E1 Port-B Link connected, LED will be “ON”
9 OPT SYNC. Green LED Optical Link connected, LED will be “ON”
10 Loop Test Green LED Loop Test Pass, Green LED will be “ON”
Pass
11 Loop Test Red LED E1 or Optical Link down / alarm present or Local
Fail / Remote IDS mis-match, Red LED will be “ON”
12 PSU 1 Green LED PSU Input-1 Connected, Green LED will be “ON”
13 PSU 2 Green LED PSU Input-2 Connected, Green LED will be “ON”

Valiant Communications 20
Teleprotection Equipment Connection Details

Rear View - VCL-TP Teleprotection - E1 Plus C37.94

VCL-TP Teleprotection - E1 Plus C37.94 - 110V DC~250V DC

E1 OPT OPT LINK PWR


EXT. ALARM EXT. ALARM E1 LOOP SYNC DOWN
SYNC TEST

COUNTER
IRIG-B

COM1

COM2

COM3

COM4

COM5

COM6

COM7

COM8
NO1

NO2

NO3

NO4

NO5

NO6

NO7

NO8
– + – + B1 B2 B3 B4 B5 B6 B7 B8
COM

COM
NC

NC
NO

NO
110~250V DC 110~250V DC
INPUT 1 INPUT 2

COM1

NC1

NC5
COM2

COM3

COM7

COM8
COM6
COM5
NC2

COM4

NC6
NC3

NC7
NC4

NC8
A1 A2 A3 A4 A5 A6 A7 A8

OUTPUTS INPUTS

VCL-TP Teleprotection - E1 Plus C37.94 - 48V DC

E1 OPT OPT LINK PWR


EXT. ALARM EXT. ALARM E1 LOOP SYNC DOWN
SYNC TEST

COUNTER
IRIG-B
COM1

COM2

COM3

COM4

COM5

COM6

COM7

COM8
NO1

NO2

NO3

NO4

NO5

NO6

NO7

NO8
– + – + B1 B2 B3 B4 B5 B6 B7 B8
COM

COM
NC

NC
NO

NO

48V DC 48V DC
INPUT 1 INPUT 2
COM1

NC1

NC5
COM2

COM3

COM7

COM8
COM6
COM5
NC2

COM4

NC6
NC3

NC7
NC4

NC8

A1 A2 A3 A4 A5 A6 A7 A8

OUTPUTS INPUTS

VCL-TP Teleprotection - E1 Plus C37.94 - 48V DC and 110V DC~250V DC

E1 OPT OPT LINK PWR


EXT. ALARM EXT. ALARM E1 LOOP SYNC DOWN
SYNC TEST

COUNTER
IRIG-B
COM1

COM2

COM3

COM4

COM5

COM6

COM7

COM8
NO1

NO2

NO3

NO4

NO5

NO6

NO7

NO8

– + – + B1 B2 B3 B4 B5 B6 B7 B8
COM

COM
NC

NC
NO

NO

48V DC 110~250V DC
INPUT 1 INPUT 2
COM1

NC1

NC5
COM2

COM3

COM7

COM8
COM6
COM5
NC2

COM4

NC6
NC3

NC7
NC4

NC8

A1 A2 A3 A4 A5 A6 A7 A8

OUTPUTS INPUTS

Valiant Communications 21
Teleprotection Equipment Connection Details

Rear View - VCL-TP Teleprotection - E1 Plus E1

VCL-TP Teleprotection - E1 Plus E1 - 110V DC~250V DC

E1-A E1-B E1-A E1-B LOOP LINK IRIG-B


EXT. ALARM EXT. ALARM SYNC SYNC TEST DOWN PWR

COUNTER

COM1

COM2

COM3

COM4

COM5

COM6

COM7

COM8
NO1

NO2

NO3

NO4

NO5

NO6

NO7

NO8
– + – + B1 B2 B3 B4 B5 B6 B7 B8
COM

COM
NC

NC
NO

NO
110~250V DC 110~250V DC
INPUT 1 INPUT 2

COM1

NC1

NC5
COM2

COM3

COM7

COM8
COM6
COM5
NC2

COM4

NC6
NC3

NC7
NC4

NC8
A1 A2 A3 A4 A5 A6 A7 A8

OUTPUTS INPUTS

VCL-TP Teleprotection - E1 Plus E1 - 48V DC

E1-A E1-B E1-A E1-B LOOP LINK IRIG-B


EXT. ALARM EXT. ALARM SYNC SYNC TEST DOWN PWR

COUNTER
COM1

COM2

COM3

COM4

COM5

COM6

COM7

COM8
NO1

NO2

NO3

NO4

NO5

NO6

NO7

NO8
– + – + B1 B2 B3 B4 B5 B6 B7 B8
COM

COM
NC

NC
NO

NO

48V DC 48V DC
INPUT 1 INPUT 2
COM1

NC1

NC5
COM2

COM3

COM7

COM8
COM6
COM5
NC2

COM4

NC6
NC3

NC7
NC4

NC8

A1 A2 A3 A4 A5 A6 A7 A8

OUTPUTS INPUTS

VCL-TP Teleprotection - E1 Plus E1 - 48V DC and 110V DC~250V DC

E1-A E1-B E1-A E1-B LOOP LINK IRIG-B


EXT. ALARM EXT. ALARM SYNC SYNC TEST DOWN PWR

COUNTER
COM1

COM2

COM3

COM4

COM5

COM6

COM7

COM8
NO1

NO2

NO3

NO4

NO5

NO6

NO7

NO8

– + – + B1 B2 B3 B4 B5 B6 B7 B8
COM

COM
NC

NC
NO

NO

48V DC 110~250V DC
INPUT 1 INPUT 2
COM1

NC1

NC5
COM2

COM3

COM7

COM8
COM6
COM5
NC2

COM4

NC6
NC3

NC7
NC4

NC8

A1 A2 A3 A4 A5 A6 A7 A8

OUTPUTS INPUTS

Valiant Communications 22
Teleprotection Equipment Connection Details

Rear Panel Description

S. No. Front Description


1 INPUT 2 Pin Power Supply Input Connectors
2 COUNTER DB25 Display Port, to connect Counter Unit
3 EXT. ALARM 1. System Operational, E1& C37.94 Port Alarms
NO, COM, NC Present CLOSED state (COM & NO are closed).
2. System Operational, E1 & C37.94 Port is in Sync. & has no alarms
OPEN state (COM and NO are open).
4 EARTH Earth connection (this must be connected to safety ground at all times)
5 OUTPUT Output Connections (Trip Commands / Relay Contacts)
NO, COM, NC
6 INPUT Input Connections (Sense Voltage Command Inputs)
A(-), B(+)
7 OPT PORT IEEE C37.94 Compliant Optical Fiber port.
8 E1-A RJ45, balanced E1-A Port
9 E1-B RJ45, balanced E1-A Port
10 E1-A SYNC. Bi-color LED (Red / Green)
11 E1-B SYNC. Bi-color LED (Red / Green)
12 LOOP TEST Loop Test Pass / Fail Status - LED (Green)
13 LINK DOWN Both Links are down, Red LED will be “ON”
14 PWR Power Indication
15 IRIG-B IRIG-B Input Connector

Input Connections Output Connections


(Sense Voltage Command Inputs): (Trip Commands / Relay Contacts):
PIN# Input# PIN# Output#
A1(-) and B1(+) Input 1 COM1, NC1 / NO1 Output 1
A2(-) and B2(+) Input 2 COM2, NC2 / NO2 Output 2
A3(-) and B3(+) Input 3 COM3, NC3 / NO3 Output 3
A4(-) and B4(+) Input 4 COM4, NC4 / NO4 Output 4
A5(-) and B5(+) Input 5 COM5, NC5 / NO5 Output 5
A6(-) and B6(+) Input 6 COM6, NC6 / NO6 Output 6
A7(-) and B7(+) Input 7 COM7, NC7 / NO7 Output 7
A8(-) and B8(+) Input 8 COM8, NC8 / NO8 Output 8

Note:
NC = Normally Closed
NO = Normally Open
COM = Common

Valiant Communications 23
Teleprotection Equipment Connection Details

OAM Port Connection

VCL-TP
INPUTS OUTPUTS

L1 L5 L1 L5

L2

L3
L6

L7
L2

L3
L6

L7
TELEPROTECTION - E1 Plus C37.94
L4 L8 L4 L8

LOOP LOOP
E1 OPT TEST TEST PSU 1 PSU 2 LOOP
SYNC SYNC PASS FAIL TEST USB COM

VALIANT
10/100BaseT
COMMUNICATIONS
MGMT

OAM Connection
RJ-45
PC (Female)

RJ-45 (Male)

RJ-45 Pinout for OAM Interface 1 234 5 6 7 8

RJ-45 (Female) Pin # Signal in RJ-45 (Female)


1 Tx+ (Data Out)
2 Tx- (Data Out)
3 Rx+ (Data In)
4 NC
5 NC RJ-45 (Female)
6 Rx- (Data In)
7 NC
8 NC

Valiant Communications 24
Teleprotection Equipment Connection Details

COM Port Connection

VCL-TP
INPUTS OUTPUTS

L1 L5 L1 L5

L2

L3
L6

L7
L2

L3
L6

L7
TELEPROTECTION - E1 Plus C37.94
L4 L8 L4 L8

LOOP LOOP
E1 OPT TEST TEST PSU 1 PSU 2 LOOP
SYNC SYNC PASS FAIL TEST USB COM

VALIANT
10/100BaseT
COMMUNICATIONS
MGMT

DB9 (Female)
Connector
PC

DB9 (Male)
Connector
To Computer

DB-9 Pinout for COM Port 5 4 3 2 1


9 8 7 6
DB-9 (Female) Pin # Signal in DB-9 (Female)
2 Transmit (Data Out)
3 Receive (Data In)
5 Ground
DB-9 (Female)

USB Port Connection

VCL-TP
INPUTS OUTPUTS

L1 L5 L1 L5

L2

L3
L6

L7
L2

L3
L6

L7
TELEPROTECTION - E1 Plus C37.94
L4 L8 L4 L8

LOOP LOOP
E1 OPT TEST TEST PSU 1 PSU 2 LOOP
SYNC SYNC PASS FAIL TEST USB COM

VALIANT
10/100BaseT
COMMUNICATIONS
MGMT

USB (Female)
PC
Connector
USB
Port

USB (Male)
Connector

Valiant Communications 25
Teleprotection Equipment Connection Details

DC Input Connection

E1 OPT OPT LINK PWR


EXT. ALARM EXT. ALARM E1 LOOP SYNC DOWN
SYNC TEST

COUNTER
IRIG-B

COM1

COM2

COM3

COM4

COM5

COM6

COM7

COM8
NO1

NO2

NO3

NO4

NO5

NO6

NO7

NO8
– + – + B1 B2 B3 B4 B5 B6 B7 B8
COM

COM
NC

NC
NO

NO
110~250V DC 110~250V DC
INPUT 1 INPUT 2

COM1

NC1

NC5
COM2

COM3

COM7

COM8
COM6
COM5
NC2

COM4

NC6
NC3

NC7
NC4

NC8
A1 A2 A3 A4 A5 A6 A7 A8

OUTPUTS INPUTS

DC Power Input Connection

24/48/110/250V DC

External Alarm Connection

E1 OPT OPT LINK PWR


EXT. ALARM EXT. ALARM E1 LOOP SYNC DOWN
SYNC TEST

COUNTER
IRIG-B
COM1

COM2

COM3

COM4

COM5

COM6

COM7

COM8
NO1

NO2

NO3

NO4

NO5

NO6

NO7

NO8

– + – + B1 B2 B3 B4 B5 B6 B7 B8
COM

COM
NC

NC
NO

NO

110~250V DC 110~250V DC
INPUT 1 INPUT 2
COM1

NC1

NC5
COM2

COM3

COM7

COM8
COM6
COM5
NC2

COM4

NC6
NC3

NC7
NC4

NC8

A1 A2 A3 A4 A5 A6 A7 A8

OUTPUTS INPUTS

NC

COM
NO

Valiant Communications 26
Teleprotection Equipment Connection Details

E1 Interface Connection

E1 OPT OPT LINK PWR


EXT. ALARM EXT. ALARM E1 LOOP SYNC DOWN
SYNC TEST

COUNTER
IRIG-B

COM1

COM2

COM3

COM4

COM5

COM6

COM7

COM8
NO1

NO2

NO3

NO4

NO5

NO6

NO7

NO8
– + – + B1 B2 B3 B4 B5 B6 B7 B8
COM

COM
NC

NC
NO

NO
110~250V DC 110~250V DC
INPUT 1 INPUT 2

COM1

NC1

NC5
COM2

COM3

COM7

COM8
COM6
COM5
NC2

COM4

NC6
NC3

NC7
NC4

NC8
A1 A2 A3 A4 A5 A6 A7 A8

OUTPUTS INPUTS

E1 Connection
RJ-45 (Female)
E1 Cable

RJ-45 (Male)

RJ-45 Pinout for E1 Interface 1 234 5 6 7 8

RJ-45 (Female) Pin # Signal in RJ-45 (Female)


1 Rx Tip (Data In)
2 Rx Ring (Data In)
4 Tx Tip (Data Out)
5 Tx Ring (Data Out)
RJ-45 (Female)

Valiant Communications 27
Teleprotection Equipment Connection Details

Optical C37.94 Interface (SFP) Connection

E1 OPT OPT LINK PWR


EXT. ALARM EXT. ALARM E1 LOOP SYNC DOWN
SYNC TEST

COUNTER
IRIG-B

COM1

COM2

COM3

COM4

COM5

COM6

COM7

COM8
NO1

NO2

NO3

NO4

NO5

NO6

NO7

NO8
– + – + B1 B2 B3 B4 B5 B6 B7 B8
COM

COM
NC

NC
NO

NO
110~250V DC 110~250V DC
INPUT 1 INPUT 2

COM1

NC1

NC5
COM2

COM3

COM7

COM8
COM6
COM5
NC2

COM4

NC6
NC3

NC7
NC4
A1 A2 A3 A4 A5 A6 A7 A8

NC8
OUTPUTS INPUTS

Receive Optical Signal


through Optical Fiber Cable

Transmit Optical Signal


through Optical Fiber Cable

Safety Warnings !!!!


For testing : Always Install Optical Attenuators.
For distance of less than 10 Kms Optical Attenuators
must be installed on the Optical Links. Otherwise, the
optics will be Permanently Damaged.

IRIG-B Connection

E1 OPT OPT LINK PWR


EXT. ALARM EXT. ALARM E1 LOOP SYNC DOWN
SYNC TEST

COUNTER
IRIG-B
COM1

COM2

COM3

COM4

COM5

COM6

COM7

COM8
NO1

NO2

NO3

NO4

NO5

NO6

NO7

NO8

– + – + B1 B2 B3 B4 B5 B6 B7 B8
COM

COM
NC

NC
NO

NO

110~250V DC 110~250V DC
INPUT 1 INPUT 2
COM1

NC1

NC5
COM2

COM3

COM7

COM8
COM6
COM5
NC2

COM4

NC6
NC3

NC7
NC4

A1 A2 A3 A4 A5 A6 A7 A8
NC8

OUTPUTS INPUTS

BNC Connector
BNC Connector (Female)
(Male)

Valiant Communications 28
Teleprotection Equipment Connection Details

Commands Selection Settings

Open Top cover of VCL-TP Teleprotection Equipment and select the command option (48/110V DC)
as per below setting on main board.

Links
VOLTS
J1-J32
MOUNTED 48V
UNMOUNTED 110V

Links
VOLTS
J1-J32
MOUNTED 48V
UNMOUNTED 110V
J14 J13
J6

J16 J15
J27 J28 J10 J9
J5

J7
J8
J19

J2
J32 J31 J29 J30 J1
J20
J25
J26

J11 J12
J22
J23

J21
J17

J4 J3

J24
J18

Valiant Communications 29
Teleprotection Equipment Connection Details

Open Top cover of VCL-TP Teleprotection Equipment and select the command option (110/250V DC)
as per below setting on main board.

Links
VOLTS
J1-J32
MOUNTED 110V
UNMOUNTED 250V

Links
VOLTS
J1-J32
MOUNTED 110V
UNMOUNTED 250V
J14 J13
J6

J16 J15
J27 J28 J10 J9
J5

J7
J8
J19

J2
J32 J31 J29 J30 J1
J20
J25
J26

J11 J12
J22
J23

J21
J17

J4 J3

J24
J18

Valiant Communications 30
Teleprotection Equipment Section 4

SECTION: 4

HyperTerminal Settings

Valiant Communications 31
Teleprotection Equipment HyperTerminal Settings

To use HyperTerminal for executing the CLI commands through COM Port (RS232), USB Port
and 10/100BaseT Management Port (LAN Port)

To use HyperTerminal for executing the CLI commands through COM Port (RS232 Serial), USB Port
and through the 10/100BaseT Management Port (LAN Port)

Important Instructions:

! The user can choose to use the HyperTerminal utility to access the equipment either through the
local serial/DB9 COM Port and USB Port.

! Alternatively, the user may use the HyperTerminal utility access the equipment through the
10/100BaseT Ethernet Management Port to remotely access the equipment over a TCP/IP
network.

! The CLI Commands shall remain same for all three options.

! Windows-based GUI is yet another option, which the user may select to configure the equipment
either through the local serial (DB9 COM) port, USB Port or the remote (10/100BaseT ethernet)
port over a TCP/IP network.

Note: HyperTerminal and GUI may not be used simultaneously. If you are accessing the equipment
through the GUI, please exit the GUI before connecting to use the HyperTerminal utility to
access the equipment through the serial / DB9 COM Port, USB Port or the 10/100BaseT
Ethernet management port for executing the CLI commands.

Valiant Communications 32
Teleprotection Equipment HyperTerminal Settings

HyperTerminal settings for COM Port (RS232) and USB Port

Click the Start button from the Task Bar of your PC.

Go to Programs>Accessories>Communications>HyperTerminal

The following screen will appear:

Enter the name, select an icon and then click OK.

The following window will appear on your screen:

Valiant Communications 33
Teleprotection Equipment HyperTerminal Settings

Select the COM** option from the drop over menu, and click OK.

The following window will appear on your screen:

** COM1 / COM2 / COM3 depends upon your PC that is in use. To confirm the same, check it out in
the properties.

[Right click on My Computer (Desktop)>Properties>Hardware>Device Manager>Port -


Communication Port (COM1)].

Valiant Communications 34
Teleprotection Equipment HyperTerminal Settings

Change the Bits per second option to “115200” and flow control option to “None”.

The final settings should be as follows:

1 Bits per second 115200


2 Data bits 8
3 Parity None
4 Stop bits 1
5 Flow control None

115200

Click on Apply, and then on OK.

The following window will appear on your screen:

Welcome to System Manager

System Configuration:
PROCESSOR : ARM926ej-s @ 398 Mhz
RAM : 64 MBytes, DDR-1
FLASH : 512 MBytes, HYNIX SLC
Version : x.y

Login:

Valiant Communications 35
Teleprotection Equipment HyperTerminal Settings

Next, click on File in the main menu and then click on Properties.

The following window will appear on your screen:

Valiant Communications 36
Teleprotection Equipment HyperTerminal Settings

Next, click on Settings tab.

Change “Emulation” to “VT100”

Next, click on “ASCII Setup”

The following window will appear:

Note: If the option of “Echo typed characters locally” is checked, you will receive double
characters.

Next, click on OK.


Valiant Communications 37
Teleprotection Equipment HyperTerminal Settings

The following window will appear on your screen:

Welcome to System Manager

System Configuration:
PROCESSOR : ARM926ej-s @ 398 Mhz
RAM : 64 MBytes, DDR-1
FLASH : 512 MBytes, HYNIX SLC
Version : x.y

Login:

Type the below user name and password to enter system configuration mode as an Administrator.

User name “superuser” (case sensitive)


Password “superuser” (case sensitive)

Note: An administrator can change network address configurations (IP address, Subnet Mask and
Gateway) and as well as configuration of authentication and authorization through serial port
(DB-9 and USB) but administrator cannot access the system through Telnet or SSH.

Note: A normal system user's account allows a user to authenticate to system services and be
granted authorization to access them on serial port (DB-9 and USB) as well as on Telnet and
SSH; however, normal system user cannot have the access to the network address
configurations and configurations of authentication and authorization.

Prompt will be generated by the system. Now the user can access/configure the system with
the CLI commands using the HyperTerminal utility.

Note: Please save the settings before you exit the HyperTerminal window for your future use.

Valiant Communications 38
Teleprotection Equipment HyperTerminal Settings

HyperTerminal settings for 10/100BaseT Management Port

Click the Start button from the Task Bar of your PC.

Go to Programs>Accessories>Communications>HyperTerminal

The following screen will appear:

Enter the name, select an icon and then click OK.

The following window will appear on your screen:

Valiant Communications 39
Teleprotection Equipment HyperTerminal Settings

Select the TCP/IP (Winsock) option from the drop over menu and click OK.

The following window will appear on your screen:

Valiant Communications 40
Teleprotection Equipment HyperTerminal Settings

Enter the IPAddress of the system in the Host address field.

The default IP Address, which is already programmed at the factory / default in the memory of the
system, is 192.168.1.101. To change the IP Address, please refer to CLI commands (OAM Interface
Configuration Commands) of the user manual.

Enter the system IP address as shown in the below screen.

Click on OK.

The following window will appear on your screen:

Welcome to System Manager

System Configuration:
PROCESSOR : ARM926ej-s @ 398 Mhz
RAM : 64 MBytes, DDR-1
FLASH : 512 MBytes, HYNIX SLC
Version : x.y

Login:

Valiant Communications 41
Teleprotection Equipment HyperTerminal Settings

Next, click on File in the main menu and then click on Properties.

The following window will appear on your screen:

Valiant Communications 42
Teleprotection Equipment HyperTerminal Settings

Next, click on Settings tab.

Change “Emulation” to “VT100”

Next, click on “ASCII Setup”

The following window will appear:

Note: If the option of “Echo typed characters locally” is checked, you will receive double
characters.

Next, click on OK.


Valiant Communications 43
Teleprotection Equipment HyperTerminal Settings

The following window will appear on your screen:

Welcome to System Manager

System Configuration:
PROCESSOR : ARM926ej-s @ 398 Mhz
RAM : 64 MBytes, DDR-1
FLASH : 512 MBytes, HYNIX SLC
Version : x.y

Login:

Type the user name and password to enter system configuration mode.

User name “superuser” (case sensitive)


Password “superuser” (case sensitive)

Prompt will be generated by the system. Now the user can access/configure the system with the CLI
commands remotely, over the 10/100BaseT Ethernet Port, using the HyperTerminal utility.

Note: Please save the settings before you exit the HyperTerminal window for your future use.

Valiant Communications 44
Teleprotection Equipment Telnet through cmd

Telnet without using HyperTerminal utility

To Telnet the system, click on Start > Run next type telnet <system IP Address> (as shown in below
screen) and click on OK. The default IP Address, which is already programmed at the factory / default
in the memory of the system, is 192.168.1.101.

The following screen will appear:

Welcome to System Manager

System Configuration:
PROCESSOR : ARM926ej-s @ 398 Mhz
RAM : 64 MBytes, DDR-1
FLASH : 512 MBytes, HYNIX SLC
Version : x.y

Login:

Type the user name and password to enter system configuration mode.

User name “systemuser” (case sensitive)


Password “systemuser” (case sensitive)

Prompt will be generated by the system. Now the user can access/configure the system with the CLI
commands remotely, over the 10/100BaseT Ethernet Port, using Telnet utility.

Valiant Communications 45
Teleprotection Equipment Section 5

SECTION: 5

Flow Chart for Installation

Valiant Communications 46
Teleprotection Equipment

Flow Chart
VCL-TP Teleprotection Equipment
(E1 / Optical C37.94)
Power Cables,LMS Cable,USB
Cable,Ethernet Cable, 8 pin i/o
connector and mounting

Unpack the system and Hardware

check all
the accessories required Connects the Cables

Connect Local and Remote


terminals over E1 cross cable
Connect the cables
to the terminals
Connect the INPUT (Sense)and
OUTPUT (Trip) wires to the 8 pin
I/O connectors 8 pin I/O Connectors
provided with
the equipment
Connect the Power Cable to Connect the INPUT (Sense) and
OUTPUT (Trip) connectors to the
Power up the terminals terminals

All the input (Sense) and Output Connect the 5 PIN External Alarm
(Trip) LEDs shall go ON and then and Safety ground connector
OFF
Wait for the equipment to
complete the boot proess Connect either the RS232/USB
Cable or Ethernet cable to access
and manage the terminals

LAMP Test push switch is given


Please perform LAMP Test to in front panel of the equipment Connect the Power Cable to
check and make sure that the all power-up the terminals
Trip and Sense alarm LEDs
are working fine

E1/Optical alarm status


LED shall glow GREEN, if E1/
Optical signal is present

Please check and make sure that


the pin-outs of the E1 Please check the Sync
Alarm
cable are connect or optical cable E1/Optical alarms
is connected properly

No Alarm

Please access the local


equipment through RS232 COM
port/USB port/ Telnet or over
SSH

Baud rate: 115200


Data Bits: 8
Parity : None Default IP Address:192.168.1.101
USB
Manage and access Telnet
SSH
Stop bits: 1 RS232
Default Mask: 255.255.255
Flow Control: None

Baud rate: 115200


Data Bits: 8
Parity : None Default IP Address:192.168.1.101
Serial
Default Login details Telnet
SSH
Stop bits: 1 ACCESS
Default Mask: 255.255.255
Flow Control: None

Local Remote
System Manage and Configure System

Note 1: In a point-to-point application, where the two Telepotection Terminals


are directly connected to each other over the E1 / Optical, one unit (local /
Master unit) must be set to work in “internal” clock mode and the second unit
Configure the equipment as remote
Configure the equipment as local CLI: setdefremote (Remote / Slave unit) must be set to work in “looop-timed” clock mode.
CLI: setdeflocal

Note 2: In a network multiplexer application, where the two Teleprotection


Terminals are connected to each other through a network multiplexer in a
Configure the clock in default PDH / SDH network, one unit (local / Master unit) must be set to work in
Configure the clock in default CLI:setdefclock “internal” clock mode and the second unit (Remote / Slave unit)
CLI:setdefclock must be set to work in “looop-timed” clock mode.

Configure the local terminal clock


Configure the local terminal clock
as recovered / looptimed
as master
CLI:systemclock=looptimed
CLI:systemclock=internal

Measure delay between


terminals

Perform the delay test on local Perform the delay test on local
sytem CLI: manualtest sytem CLI: manualtest

Check the Test Result


CLI : show/test/results/
manual/1

Please check the E1/Optical


link and system configuration
Pass

Installation is successful

End

Valiant Communications 47
Teleprotection Equipment Section 6

SECTION: 6

Ordering Information

Valiant Communications 48
Teleprotection Equipment Ordering Information

Ordering Information

CORE UNIT without Network Interface and PSUs

Part Description
VCL-TP-1531 VCL-TeleProtection Terminal Equipment
19-Inch, 2U High Rack mountable
Supports :
- Upto 8, 2-way independent-simultaneous command channels
which may be configured to operate selectively or
simultaneously over Optical / PDH / SDH network(s)
- OAM [SNMP, Telnet (RJ45 Port) and
Serial Port (USB and DB-9 COM Port)]
- Graphical User Interface (GUI) and Network Management
Software (NMS), System Core Cables, Installation
Accessories, Documentation, System User Disk etc (Set)
[# Add IRIG-B / NTP / 1588 PTP Time synchronization (optional)]
[# Add Network Interface]
[# Add Power Supply]
[# Select / Specify Command Voltage]
[# Add Trip Counter Display (optional)]

# Add IRIG-B Time Synchronization option

Part Description
IRIG-B / NTP IRIG-B / NTP Time Synchronization Option
(50 Ohms BNC Input for IRIG-B and RJ45 for NTP)

Valiant Communications 49
Teleprotection Equipment Ordering Information

# Add Network Interface (Any One Option)

Part Description
2715-2730-2736 1+1 redundant, automatic protection E1 interface
- 2 x 2.048Mbps E1 (120 Ohms) digital data interface [RJ45 (F)]
2715-2730-2736-MP - 2 x 2.048Mbps E1 (120 Ohms) digital data interface [RJ45 (F)]
(Point-to-Multi-Point Interface)
2715-2730-2733 1+1 redundant, automatic protection E1 / C37.94 interface
- 1 x 2.048Mbps E1 (120 Ohms) digital data interface [RJ45 (F)]
- 1 x C37.94 protocol Optical Interface [without SFP]
2715-2730-2734 1+1 redundant, automatic protection E1 / C37.94 interface
- 1 x 2.048Mbps E1 (120 Ohms) digital data interface [RJ45 (F)]
- 1 x C37.94 protocol Optical 820nm, (MM, TX/RX, ST)
E1-120-75-CONV E1 120 Ohms (RJ45) to E1 75 Ohms (BNC) Converter

# Specify Command Voltage (Any One Option)

Part Description
CV024048 Command Voltages: 16-24V DC / 38-48V DC
CV048110 Command Voltages: 38-48V DC / 110V-125V DC
CV110220 Command Voltages: 110-125V DC / 220-250V DC

# Add Power Supply Option (Any One Option)

Part Description
AC220 1 x 110~240V AC Power Supply Input
AC220R 2 x 110~240V AC Power Supply Input [Redundant]
DC048 1 x 48V DC Power Supply Input
DC110 1 x 110V~125V DC Power Supply Input
DC220 1 x 110V~250V DC Power Supply Input
DC048R 2 x 48V DC Power Supply Input [Redundant]
DC110R 2 x 110V~125V DC Power Supply Input [Redundant]
DC220R 2 x 110V~250V DC Power Supply Input [Redundant]

Valiant Communications 50
Teleprotection Equipment Ordering Information

# Select SFP Option (1 SFP per UNIT):

Part Description
VCL-EMOD SFP Transceiver, Duplex LC, 14dB, 820nm,
0469-TP 1 Mile / 2Km, MM (Multi-Mode)
VCL-EMOD SFP Transceiver, Duplex LC, 13dB, 1310nm,
0193-TP 9 Miles / 15Km, SM (Single-Mode)
VCL-EMOD SFP Transceiver, Duplex LC, 29dB, 1310nm,
0194-TP 25 Miles / 40Km, SM (Single-Mode)
VCL-EMOD SFP Transceiver, Duplex LC, 37dB, 1550nm,
0217-TP 49 Miles / 80Km, SM (Single-Mode)
VCL-EMOD SFP Transceiver, Duplex LC, 37 dB, 1550nm,
0402-TP 99 Miles / 160Km, SM (Single-Mode)
VCL-EMOD SFP Transceiver, Duplex LC, 46dB, 1550nm,
0171-TP 111 Miles / 180Km, SM (Single-Mode)
VCL-EMOD SFP Transceiver, Duplex LC, 47dB, 1550nm,
0244 -TP 124 Miles / 200Km, SM (Single-Mode)
VCL-EMOD SFP Transceiver, Duplex LC, CWDM, 46dB,
0364-TP 1550nm, 161 Miles / 260Km, SM (Single-Mode)
VCL-EMOD SFP Transceiver, Duplex LC, CWDM, 50dB,
0490-TP 1550nm, 167 Miles / 270Km, SM (Single-Mode)

# Add Trip Counter Display (External Trip Counter Display) – optional, if required

Part Description
VCL-DISP-1599- Trip Counter Display with
1597-08-DC048 – 16 x Trip (8 Input and 8 Output) Counter Display
– 8 x User Assignable External Relay Alarm outputs
19-Inch, 2U High Rack mountable
– 1 x (-) 48V DC Power Supply Input
VCL-DISP-1599- Trip Counter Display with
1597-08-DC048R – 16 x Trip (8 Input and 8 Output) Counter Display
– 8 x User Assignable External Relay Alarm outputs
19-Inch, 2U High Rack mountable
– 2 x (-) 48V DC Power Supply Input

Optional - Trip Counter Display Panel and Alarm Extension Unit:


! The Trip Counter Display Panel and Alarm Extension Unit can be installed in conjunction with the
Teleprotection unit to display the count of the “Trip Input Sense” and “Trip Output Initiate” events
and to obtain and extend additional alarm outputs to the Sub-Station “Alarm Annunciator” panel.
! 16, (8 Inputs and 8 Outputs) Trip Counter Display Panel to display the count of the “Trip Input
Sense” and “Trip Output Initiate” events
! Additionally provides 8 user configurable external dry contact alarm outputs to extend up to 8,
separate user assignable alarms
! Each alarm output can be individually assigned to any type of event, including failure of
Transmission Link, PSU Failure Alarm, Trip Input Sense / Trip Output Initiate Commands.

Note :
The Trip Counter Display and Alarm Extension Unit may, or may not be ordered with the
Teleprotection Equipment, depending upon the user requirements.

Valiant Communications 51
Teleprotection Equipment Ordering Information

# Add VCL-TP external feed-through terminal block panel - optional, if required

Part Description
VCL-HTER VCL-TP external feed-through Knife disconnect
1030-60IO Terminal Block (TB) 60-I/O
(2 x input and 2 x output)
19" 2U High Rack Mount Version
VCL-HRNS 1294-08-01.00M 8-Point, Feed-through Cable
(8PINF/RA/Screw Flange to open, 1 meter)
[4 cables required to order]
VCL-HRNS 1294-04-01.00M 4-Point, Feed-through Cable
(8PINF/RA/Screw Flange to open, 1 meter)
[2 cables required to order]
VCL-HRNS 1294-03-01.00M 3-Point, Feed-through Cable
(5PINF/RA to open, 1 meter)[2 cable required to order]

Technical specifications are subject to changes without notice.


All brand names and trademarks are the property of their respective owners.
Revision 03 – January 12, 2022

U.K. U.S.A. INDIA

Valiant Communications (UK) Ltd Valcomm Technologies Inc. Valiant Communications Limited
Central House Rear Office, 4000 Ponce de Leon Blvd., 71/1, Shivaji Marg,
124 High Street, Hampton Hill, Suite 470,Coral Gables, New Delhi - 110015,
Middlesex TW12 1NS, United Kingdom FL 33146, U.S.A. India

Valiant Communications 52

You might also like