TOKY

The HP Series Timer Relay user manual provides detailed instructions on the device's features, operation sequences, and technical specifications. It includes information on setting timing values, output modes, and various menu functions, along with dimensions and ordering codes for different models. The relay supports a wide range of timing settings and has options for power supply and mounting configurations.

Uploaded by

Brian Zuluaga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
229 views1 page

TOKY

The HP Series Timer Relay user manual provides detailed instructions on the device's features, operation sequences, and technical specifications. It includes information on setting timing values, output modes, and various menu functions, along with dimensions and ordering codes for different models. The relay supports a wide range of timing settings and has options for power supply and mounting configurations.

Uploaded by

Brian Zuluaga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Setting Value Modify Menu N Mode

HP Series Timer Relay user Manual 4. Panel Instruction


:Timing Value Display Window Menu Sepuence Menu Function Setting Range Power
:Setting Value Display Window Pause
Under the condition of Timing status, press
Features: :Hour (H), Minute (M), Second (S) Indicate Light Timing Status
to enter into setting value modify menu. Reset
⊙ Dual line 4 digit LED display; :Relay Output Indicate Light Timing value and
⊙ High timing accuracy; Output
: Function, SET Key The parameter can be setting freely output will be keeped
⊙ Range of setting time and delay time :Relay Timing value setting menu
between 0.01S-9999H according to Setting Value T.off before input reset.
can be setted freely (11 kinds); :Increase Key When Timing value≥T.off
the differnet timing range that you
:Right Shift Key setting value, Relay ON. UP 0
⊙ Multi-mounting size can be choosed; choosed in function menu
Setting Value T.off
: Reset Key SET
DOWN 0

1. Model Illustration : Output delay setting menu, relay The parameter can be setting freely
5. Operation Sequence will reset after Relay OFF between 0.01S-9999H according to
the differnet timing range that you R Mode
time≥T.on setting value.
HP 4 R B 4 0 W Design Code Function Menu SET (N,F mode without this menu) choosed in function menu
Communication Function: 0: Without Communication Menu Sepuence Menu Function Setting Range Power
Display: 4: 4 Digit Display Under the condition of timing status, press SET more than 3S to enter into function menu, after Pause After timing value
Output Alarm: B: One Alarm Timing Status parameter modification, press SET for a long time to back to timing status. If there is
no any operation for more than 10S, the meter will return back to the timing status
6. Dimensions (mm) Reset
reached T.off setting
value, Relay ON,
Output Type: R: Relay Output S: SSR Output 按SET>3S automatically (the modification will not be saved)
Side Face Size Mounting Size Output display value will show
Power Supply: Blank: 220VAC F: 24VDC :Timing value range choose menu, Panel Size T.on timing, relay will
99.99S 999.9S 9999S 99M59S 99.99M
lower line LED display Max timing C G +0.5
-0 H Setting Value T.off reset and start the next
Dimension: 4:48H*48W 6:96H*48W 7:72H*72W (Unit:mm)
value, H,M,S indicate light seperately 9999H 999.9H 99.99H 99H59M 9999M 999.9M A D E Setting Value T.on
to show the relative units. 0
cycle T.off timing after
HP Series Timer Relay SET J +0.5 UP
:Delay time range choose menu,
-0
timing value reached
Setting Value T.off T.on setting value
lower line LED display Max delay K
2. Ordering Code 99.99S 999.9S 9999S 99M59S 99.99M B F
DOWN 0
time value, H,M,S indicate light
seperately to show the relative units. 9999H 999.9H 99.99H 99H59M 9999M 999.9M
Model Display Power Supply Dimension (mm) Alarm SET (F,N mode without this menu) C Mode
HP4-RB40W 4 AC 220V±10% 50Hz 48H*48W One
Add Timing Mode: Timing count value increase Model A B C D E F G H(Min) J K(Min)
HP6-RB40W 4 AC 220V±10% 50Hz 96H*48W One from 0 to setting value 4:(48*48) 48 48 97.5 6.5 91 45 45.5 25 45.5 25
:Timing mode choose menu Power
HP7-RB40W 4 AC 220V±10% 50Hz 72H*72W One Minus Timing Mode: Timing count value decrease 6:(96*48) 48 96 97.5 9 88.5 89.5 45 25 90 25
SET from setting value to 0 7:(72*72) 72 Pause After timing time
72 97.5 9 88.5 67 67.5 25 67.5 25
reached T.off setting
3. Technical Specification : Effective pulse width of Input signal
:1mS Reset time, Relay ON,
display value reset and
Power Supply AC220V±10% 50Hz
SET
choose menu. :20mS 7. Output Logic Table Output
start next cycle timing.
≤3VA
Setting Value T.off Relay will reset after
Power Consumption : N Mode : F Mode Setting Value T.on
F Mode 0 reached T.on setting
Mounting Mode Panel Mount : Output Mode choose menu UP
: C Mode : R Mode value.
0.01-99.99S、0.1-999.9S、1-9999S、1-99M59S、0.01-99.99M、0.1-999.9M、 Setting Value T.off
Timing Range SET 0
1-9999M、1-99H59M、0.01-99.99H、0.1-999.9H、1-9999H Power DOWN
: With start function, after power should press
or short connect PAUSE terminal, the meter Pause
Timing Accuracy ±0.1%±0.05sec : Start function
start to work.
Reset Mode Panel reset, External Connection reset, Auto Reset or Power OFF Reset can be choosed
: Without start function, the meter will work after
power on.
Reset 8. Connection Drawing
low level effective
SET
Output Timing Value continue to
Input Signal : Power Off Data save function
increase or decrease,
Terminal Capacity 3A/250VAC or 6A/30VDC : Power OFF data save choose menu Max Timing Value
output will be keeped
: Without Power Off Data save function
Pulse Interference (AC) ±1.8KV Setting Value T.off before input reset.
SET HP7
Dielectric AC 1500V 1min : Without Lock function UP 0 HP4
Insulation Impedance DC 500V ≥ 100MΩ : Lock Panel reset Setting Value T.off HP6
: Lock key menu
≤85% RH DOWN 0
Ambient Humidity : Lock setting value menu + function menu

Ambient Temperature 0~50℃ SET : Lock panel reset + setting value menu
+ function menu Note: If there is any change, please subject to the drawing on the meter!

Page 01 KKHPE02-A/0-20140313 Page 02 KKHPE02-A/0-20140313 Page 03 KKHPE02-A/0-20140313 Page 04 KKHPE02-A/0-20140313