The CellD 300 power system is a compact and efficient solution designed for telecom infrastructure, featuring high-efficiency rectifiers and easy installation. It supports various applications including wireless and fixed line services, with a range of technical specifications for different load capacities. Delta Energy Systems emphasizes quality and reliability, optimizing total cost of ownership for users.

Uploaded by

Yakoub Boumelit
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views2 pages

FS CellD 300 en

The CellD 300 power system is a compact and efficient solution designed for telecom infrastructure, featuring high-efficiency rectifiers and easy installation. It supports various applications including wireless and fixed line services, with a range of technical specifications for different load capacities. Delta Energy Systems emphasizes quality and reliability, optimizing total cost of ownership for users.

Uploaded by

Yakoub Boumelit
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

3791652900

CellD 300
Power system

Description
CellD systems are small, just like cells. They can be embedded in the telecom infrastructure and are often used in
OutD outdoor solutions. The products in this series are light and designed especially for installations with limited
space offering high density of the installed power.
The system includes high efficiency rectifiers, AC and DC connections, battery connection and either ORION or
PSC 3 controller. In addition to advanced supervision, short depth and easy installation are the success factors of the
system.
Delta is known for quality and product reliability – in this solution that has been combined to optimize the total cost
of ownership.

Main features
19in or 21in rack mounted system up to 250 A loads
Integrated distribution unit and rectifiers shelf with combinations from 4U to 7U
High efficiency rectifiers up to 96,2 %
All connections easily accessible from the top
All battery and load breakers accessible at the front
Sliding mechanism to support easy access to the output connections
Option for enhanced monitoring and controlling

Applications
Wireless applications, network base stations, LTE
Fixed line applications, broadband services
Transmission
3791652900

CellD 300
Power system

Technical specifications
1600B-48- 1600B-48- 2400B-48- 2900B-48- 2900B-48- 2900B-48- 2900B-48- 4000B-48-
6 9 5 3 5 6 6 5
DPR 1600B- DPR 1600B- DPR 2400B- DPR 2900B- DPR 2900B- DPR 2900B- DPR 2900B- DPR 4000B-
Rectifier module
48 (max. 6) 48 (max. 9) 48 (max. 5) 48 (max. 3) 48 (max. 6) 48 (max. 6) 48 (max. 6) 48 (max 5)
Efficiency 92 % 92 % 93.5 % 96.2 % 96.2 % 96.2 % 96.2 % 95 %
Install power (max.
9.6 kW 14.4 kW 12 kW 8.7 kW 14.5 kW 17.4 kW 17.4 kW 20 kW
config.)
Input current (3 phase) 19 ARMS 28,5 ARMS 30 ARMS 16 ARMS 32 ARMS 32 ARMS 32 ARMS 37 ARMS
Input protection
3 x 20 A 3 x 32 A 3 x 32 A 3 x 20 A 3 x 40 A 3 x 40 A 3 x 40 A 3 x 50 A
(recom.)
266 mm 311 mm 222 mm 177 mm 222 mm 266 mm 222 mm 266 mm
Height (overall)
(6U) (7U) (5U) (4U) (5U) (6U) (5U) (6U)
444 mm 444 mm 444 mm 495 mm 444 mm 444 mm 495 mm 444 mm
Width (body)
(19”) (19”) (19”) (21”) (19”) (19”) (21”) (19”)
Depth 315 mm 315 mm 410 mm 315 mm 315 mm 315 mm 315 mm 455 mm

AC input Control / Monitoring


AC configuration 1x 3PH,2x 3PH or configurable Controller ORION or PSC 3

Input voltage range 80 … 300 VRMS Local interface Display, menu structure, keypads, LEDs

Frequency range 45 - 66 Hz 6 alarm relays, modems,


Remote monitoring
WEB Interface, SNMP protocol
Mains connection Cable / Screw terminals
N loss, Internal OVP, Inbuilt fuses
Input protection Others
(L+N), High input voltage
Operating temperature -45 - +65 °C

DC output Humidity (relative) 95 % max, non cond.

Output voltage range 42-58 VDC; 53.5 VDC nom. Environment standard ETSI EN 300 019-1-3

Output current (max.) 250 A Safety standard IEC 60950


Load breakers (space 15-21 x 18 mm MCB (19IN), 21-24 x 13 EMC standard EN 300 386
depends on frame size, mm MCB (19IN), 18-24 x 18 mm MCB
Weight (depending on config.) 14 - 25 kg
battery fuses and breaker type) (21IN), 25 x 13 mm MCB (21IN)
2-6 x MCB (up to 125A), 2-3 x MCB
Battery breakers
(up to 200A), 2 x MCB (up to 300A) Ordering
LVD (battery) 250A (standard) System 3799294100
PLD (not critical loads) 150 A or 250 A (option) Rectifier DPR 1600B-48 TPS1010001B
Inbuilt fuses (both poles), High output Rectifier DPR 2400B-48
Output protection
voltage, Over-temperature protection Rectifier DPR 2900B-48 ESR-48/56B F-S
Rectifier DPR 4000B-48 TPS1010016C

Delta Energy Systems (Finland) Oy


Juvan teollisuuskatu 15, FIN-02921 Espoo
Phone: +358 9 849 660, Fax: +358 9 8496 6100