Installation B
Installation B
Table of Contents
Introduction 1
SICAM Installation Requirements 2
SICAM PAS/PQS
Installing SICAM PAS/PQS 3
V8.22 Uninstalling SICAM PAS/PQS 4
Licensing 5
Installation
OPC 6
System Time 7
Appendix A
Literature
Index
E50417-M8976-C432-C9
NOTE
i For your own safety, observe the warnings and safety instructions contained in this document, if available.
This manual describes how to install the SICAM PAS/PQS software system. It contains instructions for installing
the SICAM PAS/PQS base software system.
Other manuals may be required if you wish to install additional options.
Target Audience
This manual is intended for personnel who install the SICAM PAS/PQS base software system.
Scope
This manual is valid for SICAM PAS/PQS.
Standards
SICAM PAS/PQS has been developed in compliance with ISO 9001:2008 standard.
Additional Support
For questions about the system, contact your Siemens sales partner.
Training Courses
You can request the individual training course offer at our Training Center:
Siemens AG
Siemens Power Academy TD Phone: +49 911 9582 7100
Humboldtstraße 59 E-mail: poweracademy@siemens.com
90459 Nuremberg Internet: www.siemens.com/poweracademy
Germany
Notes on Safety
This document is not a complete index of all safety measures required for operation of the equipment (module
or device). However, it comprises important information that must be followed for personal safety, as well
as to avoid material damage. Information is highlighted and illustrated as follows according to the degree of
danger:
! DANGER
DANGER means that death or severe injury will result if the measures specified are not taken.
² Comply with all instructions, in order to avoid death or severe injuries.
! WARNING
WARNING means that death or severe injury may result if the measures specified are not taken.
² Comply with all instructions, in order to avoid death or severe injuries.
! CAUTION
CAUTION means that medium-severe or slight injuries can occur if the specified measures are not taken.
² Comply with all instructions, in order to avoid moderate or minor injuries.
NOTICE
NOTICE means that property damage can result if the measures specified are not taken.
² Comply with all instructions, in order to avoid property damage.
NOTE
i Important information about the product, product handling or a certain section of the documentation
which must be given attention.
Proper Use
The equipment (device, module) may be used only for such applications as set out in the catalogs and the
technical description, and only in combination with third-party equipment recommended and approved by
Siemens.
Problem-free and safe operation of the product depends on the following:
• Proper transport
• The equipment must be grounded at the grounding terminal before any connections are made.
• All circuit components connected to the power supply may be subject to dangerous voltage.
• Hazardous voltages may be present in equipment even after the supply voltage has been disconnected
(capacitors can still be charged).
• Operation of equipment with exposed current-transformer circuits is prohibited. Before disconnecting the
equipment, ensure that the current-transformer circuits are short-circuited.
• The limiting values stated in the document must not be exceeded. This must also be considered during
testing and commissioning.
OpenSSL
This product includes software developed by the OpenSSL Project for use in OpenSSL Toolkit (http://
www.openssl.org/).
This product includes software written by Tim Hudson (tjh@cryptsoft.com).
This product includes cryptographic software written by Eric Young (eay@cryptsoft.com).
Preface.......................................................................................................................................................... 3
1 Introduction..................................................................................................................................................8
1.1 System Types...................................................................................................................... 9
1.2 Installation Variants............................................................................................................ 9
2 Installation Requirements.......................................................................................................................... 11
2.1 Hardware Components..................................................................................................... 12
2.2 Operating System............................................................................................................. 12
2.3 Configuring the Windows Network Operation....................................................................14
2.4 Compatibility.................................................................................................................... 15
2.5 Further Requirements....................................................................................................... 16
5 Licensing.....................................................................................................................................................61
5.1 Introduction......................................................................................................................62
5.2 Using Online Software Delivery (OSD) to License a SICAM PAS/PQS System, V8.17
and Later.......................................................................................................................... 63
5.3 Connecting the DIP to the Full Server.................................................................................64
6 OPC............................................................................................................................................................. 65
6.1 Setting up the OPC Server................................................................................................. 66
6.1.1 Starting the DCOM Configuration.................................................................................66
7 System Time............................................................................................................................................... 85
7.1 Updating Time Zones........................................................................................................ 86
7.2 Synchronizing Time...........................................................................................................86
7.2.1 Network Time Protocol Daemon...................................................................................87
7.2.2 Time Synchronisation with Telecontrol Protocols..........................................................88
7.2.3 Configuration File for NTPD..........................................................................................90
7.2.4 Example – External Radio Clock as Timer...................................................................... 93
A Appendix.................................................................................................................................................... 98
A.1 Several SICAM PAS/PQS Versions on One Computer........................................................... 99
A.2 Virtualization Solutions................................................................................................... 100
A.3 Connecting a Substation via IEC 60870-5-101................................................................. 102
A.4 Connecting a SIMEAS R Device........................................................................................ 107
A.5 Modem (TAPI Interface).................................................................................................. 108
A.6 Modem via COM Port (Hayes Compatible)....................................................................... 120
A.7 Working with the Multilanguage Manager Tool............................................................... 125
A.8 Licensing - General Information.......................................................................................127
A.9 Feature Enabler...............................................................................................................128
A.10 Using a Dongle for Licensing........................................................................................... 130
A.11 Using a Soft License for Licensing.................................................................................... 130
A.12 Software Licensing - General Information........................................................................ 130
A.13 Licensing a System with Internet Access.......................................................................... 131
A.14 Licensing a System without Internet Access..................................................................... 134
A.15 Extending a System with Internet Access......................................................................... 139
A.16 Extending a System without Internet Access....................................................................140
A.17 Extending a Dongle via Internet...................................................................................... 142
A.18 Importing the License File............................................................................................... 143
A.19 Using a Dongle to License a SICAM PAS/PQS System, V8.01 and Earlier.............................144
A.20 Connecting the DIP to the Full Server...............................................................................147
Literature.................................................................................................................................................. 149
Index.........................................................................................................................................................151
All software components of SICAM PAS/PQS are stored on the SICAM PAS/PQS DVD or in the downloaded
zip-file. The dongle included in the scope of delivery and the function-specific license keys, a Soft License or
ALM-Licenses determine which features are enabled on the computer.
1.1 System Types 9
1.2 Installation Variants 9
• Stand-alone system
• Distributed system
For configuration examples, refer to /1/ SICAM PAS, Overview and /2/ SICAM PQS, Overview.
Stand-Alone System
SICAM PAS/PQS as a stand-alone system runs on one single computer, the Full Server. The SICAM PAS/PQS
Full Server holds the data distribution system of SICAM PAS/PQS, the relational database system and the user
interface. Protocol drivers and additional SICAM PAS/PQS components are located on this computer.
Distributed System
SICAM PAS/PQS as a distributed system runs on several computers. The following rules apply in this configu-
ration:
• One computer is the Full Server. The SICAM PAS/PQS data distribution system, the Relational Database
Management System (RDBMS) and the user interface are located on this computer. Protocol drivers and
certain other applications can also reside on this computer.
Every distributed SICAM PAS/PQS configuration must have exactly 1 Full Server.
• The other computers in this configuration are operated as DIPs (Device Interface Processors). These
computers host the protocol drivers and additional functions such as the fault location function, the
archive, and also the user interface.
Both types of SICAM PAS/PQS are installed using the same installation routine. The installation process for
these 2 types of SICAM PAS/PQS is almost identical. During the installation, you only need to specify whether
the computer is to be operated as a stand-alone system/Full Server or as a DIP. It is nevertheless essential to
understand which type of system you are installing.
The data exchange between the DIP and the Full Server must be ensured during operation.
• Demo version
• Licensed version
The installation DVD of SICAM PAS/PQS includes all files of the software components. During the installation
process, you must specify whether you want to install a licensed version or a demo version.
Demo Version
For the demo version, neither a dongle nor a Soft License nor ALM-Licenses are required.
In the demo version, SICAM PAS/PQS is installed as a stand-alone system, see 1.1 System Types.
In the demo version, SICAM PAS/PQS runs for 3 hours. After 3 hours, the demo version – runtime is stopped.
SICAM PAS/PQS UI – Configuration can be further used. After each restart of your computer, the runtime is
available for another 3 hours.
Be aware of the following additional restrictions:
• Projects created in the demo version cannot be used in the licensed version.
Licensed Version
The licensed version requires a dongle, Soft License, or an ALM License.
In the licensed version, SICAM PAS/PQS can be installed and operated both as a stand-alone system and as a
distributed system.
SICAM PAS/PQS is a 32-bit application with specific requirements with regard to the hardware components
and the operating system. Additionally, it must be ensured that the network has been properly installed.
2.1 Hardware Components 12
2.2 Operating System 12
2.3 Configuring the Windows Network Operation 14
2.4 Compatibility 15
2.5 Further Requirements 16
• Processor:
– Minimum: Intel Core 2 Duo 1.6 GHz
– Recommended: Quad Core CPU 3 GHz
• Graphics card:
– Minimum: 1024 x 768 pixel
– Recommended: 1920 x 1080 pixel
• DVD drive
• Keyboard
• Mouse
• Network interface
• USB port
NOTE
Optionally
• COM Expander
• ISDN FRITZ!Card
For existing projects which are migrated to the new SICAM PAS/PQS version, the following operating systems
can continue to be used:
NOTE
i .NET Framework V4.7.2 or later is required. For operating systems like Windows 10 (earlier than 1803),
Windows 2016 Server or earlier, install .NET Framework using the Windows update or the offline installer.
To download the offline installer, refer to https://dotnet.microsoft.com/download/dotnet-framework/thank-
you/net48-offline-installer.
NOTE
i If the Windows Server 2008 R2 Standard SP1 is installed on the Full Server for a distributed SICAM
PAS/PQS system (the Full Server and the DIP are different computers) or a redundant SICAM PAS/PQS
system, the following must be observed for the Full Server:
• The DNS Client, function search and resource publishing, SSDP search, and UPnP device host services
must have been enabled and started.
If these services are not started, the automatic network share cannot be permanently enabled.
• The ports of the programs that are used for the communication between Full Server and DIPs must
be opened in the firewall. This refers to the ports of the btiserver.exe, dbsrv17.exe, and DSIServer.exe
programs.
NOTE
i To install SICAM PAS/PQS on Windows 7/Windows Embedded 7 (SICAM Station Unit V2.40, 32-Bit),
you must download the KB2999226, KB3083324, KB4474419, and KB4499175 patches from https://
www.catalog.update.microsoft.com/Home.aspx and execute them.
Windows Update
Siemens recommends you update the patches using the Windows Update service before installing/updating
SICAM PAS/PQS. However, for an uninterrupted system operation, it is always recommended that you deacti-
vate the automatic update of the operating system.
The applications of SICAM PAS/PQS use various network services, such as TCP/IP, SNTP, DCOM, and ODBC.
Unsupervised operation of SICAM PAS/PQS is restricted by Windows Update because of the following reasons:
• The function of the network services could possibly be restricted by the Windows security updates.
• Manual intervention into the computer configuration is required (for example, other settings of the
Windows firewall).
• The computer is connected with the Internet to perform the update, which involves a security risk.
NOTE
i If the SSR service does not start after any Windows security updates, reinstall SICAM PAS/PQS.
Standby Mode
To operate SICAM PAS/PQS, it must be ensured that the operating system does not switch to standby mode.
✧ Select Never for Standby in the Control panel, Energy options, Energy scheme tab.
Automatic Maintenance
Automatic maintenance is a scheduled task in Windows 8.1 and later versions which performs many pre-
defined tasks at specific time intervals. Automatic Maintenance stops all the running maintenance tasks and
resumes them when the system is in idle state.
To avoid slowness or non-responsiveness:
✧ Perform Automatic Maintenance regularly on a system.
You change the scheduled time of all the maintenance tasks via
Control Panels > All Control Panels Items > Action Center.
Siemens recommends you deactivate the setting Check for solutions to problem reports under Mainte-
nance to avoid sending the data to Microsoft and look for possible solution.
NOTE
i For protection against malware infections, Siemens recommends to enable the latest virus patterns of
Microsoft Security/Windows Defender.
If you use other antivirus software follow the instructions and recommendations of the manufacturer.
Siemens recommends to specify the following directories in the list of exceptions:
• Archive directory
• %PAS_APPDATA%
• %ProgramData%\Siemens\SettingsManager
• TCP/IP must be installed in any case, that is, even for a stand-alone system.
• Your computer must be assigned a valid TCP/IP name. Be aware that TCP/IP name conventions are
stricter than Windows conventions. The host name must neither start with a number nor include a blank
or special characters with the exception of _ and - . For example, My PC is a valid name under Windows.
Due to the blank included, it cannot be used with TCP/IP.
• Before you install SICAM PAS/PQS, TCP/IP must be configured. SICAM PAS/PQS cannot be installed prop-
erly without a configured TCP/IP. An Ethernet adapter is required for the configuration of TCP/IP.
• Power saving features: Many hardware components have power saving features installed, usually as
part of the BIOS on the computer. These features slow down or stop the system CPU during a period
of inactivity. Additionally, the screen display enters the save mode and the hard disk stops rotating. As
almost no industrial standards are available for these features, they may vary significantly depending on
the individual manufacturer and model. For this reason, if these features have been enabled, SIEMENS
cannot guarantee that the SICAM PAS/PQS software runs without any problems.
• If you operate SICAM PAS/PQS in a network with other computers, further configuration steps may
be required: In addition to IP addresses and network connections, a mechanism for the assignment of
computer names and IP addresses may be required in a TCP/IP network. The following 4 assignment
options are available:
– DNS <HELP=glossary.hlp TOPIC=gls_domain_namesystem>
– WINS <HELP=glossary.hlp TOPIC=gls_WINS>
– Broadcast name resolution
– HOSTS and LMHOSTS <HELP=glossary.hlp TOPIC=gls_lmhosts> files
In small networks in which IP addresses do not change, network connections can use a HOSTS or
LMHOSTS file for the assignment of computer names and IP addresses. For more detailed information,
refer to the corresponding Windows documentation.
• For a distributed SICAM PAS/PQS system, the Windows network interfacing must be configured on each
computer in the system.
• For a SICAM PAS/PQS computer, it is recommended to configure Windows on the computer in such a way
that the computer reboots automatically after a failure. Refer to your Windows/BIOS documentation for
instructions.
• The network share must be permanently enabled. It is not enabled by default in all operating systems,
for example, Windows Server 2008 R2.
2.4 Compatibility
SICAM Station Unit
The latest version of SICAM PAS/PQS can be used on the SICAM Station Unit V2.40.
NOTE
i From V8.22 onwards, WinPcap is replaced by Npcap. Npcap can be installed in the following ways:
• By selecting Install from the Windows Security dialog which pops-up during the installation of SICAM
PAS/PQS
– or
OSCOP P
If you uninstall OSCOP P from the computer where both SICAM PAS/PQS and OSCOP P are installed you must
reinstall SICAM PAS/PQS to ensure it functions properly.
SIGRA
After the installation of the latest version of SICAM PQS, if scheduled reports are configured and you repair
SIGRA on the same computer, the SICAM PAS/PQS latest version installation must also be repaired.
Discontinuation
The Windows XP and Windows 2003 Server operating systems, as well as the PROFIBUS FMS Master
application and the data transmission via an X.21 interface are no longer supported by SICAM PAS/PQS V8.06
and later.
If you want to continue to use these functionalities, use SICAM PAS/PQS V8.05 and note the corresponding
documentation.
• To install SICAM PAS/PQS and SICAM SCC on the same computer, at least V7.00 must be installed for both
of them.
• Install the TCP/IP network interfacing for Windows before installing SICAM PAS/PQS. For more detailed
information on the installation of the network interface for Windows, refer to the Windows documenta-
tion.
• To configure SICAM PAS/PQS for the data exchange with PROFIBUS DP devices, install the PROFIBUS
interface card (for example, CP5613/14) and the corresponding software components before installing
SICAM PAS/PQS.
• If SICAM PAS/PQS is already installed on your computer and you want to perform a reinstallation or an
upgrade, Siemens recommends you back up your database. During a reinstallation of SICAM PAS/PQS, the
system prompts you to specify whether the existing database is to be maintained or overwritten.
• A readme file
• SIMEAS R PAR
• The manuals
NOTE
i Read the installation instructions carefully. Before you install SICAM PAS/PQS, check whether all system
requirements are met, and in particular those for the installation and configuration of the TCP/IP network
interfacing. After the installation and configuration of the TCP/IP network interfacing, you must reboot your
computer.
NOTE
NOTE
i If DIGSI 5 is installed on your computer, you must uninstall it first before installing SICAM PAS/PQS. Perform
a new installation of DIGSI 5 after installing SICAM PAS/PQS.
NOTE
i If SICAM PAS Secure Communication Add-on is installed on your computer, you must uninstall it first
before installing SICAM PAS/PQS.
3.2 Installation
The sequence of installation of SICAM PAS/PQS includes the following steps:
• 3.2.2 Silent Installation that runs unattended with parameters defined in an XML file and is executed via
command prompt
NOTE
i The path of the Setup directory must not contain any special characters.
² Select the language to be used for the installation process and then click OK to confirm.
The product selection dialog opens.
NOTE
i If SICAM PAS V6.00 has already been installed on your computer, the system prompts you to uninstall
it. Create a backup copy of your SICAM PAS/PQS database. Uninstall SICAM PAS/PQS and restart the
installation.
When installing the latest version of SICAM PAS/PQS, SICAM PAS/PQS V7.00 and later is uninstalled
automatically.
NOTE
i All further installation steps are identical for SICAM PAS and SICAM PQS. In this chapter, the installation is
illustrated based on the example of SICAM PAS.
• Demo Project
Configuration database of a demo project
• Device Descriptions
Device templates
• Documentation
SICAM PAS/PQS manuals in PDF format
• UI – Operation Client
Access to SICAM PAS/PQS UI – Operation from a remote computer via browser
• Core components
System files of the SICAM PAS/PQS software
• Database
SQL Anywhere database system SQL scripts can be executed using Interactive SQL. You can customize
the destination path of the database.
• System Services
System files of the SICAM PAS/PQS software. You can customize the destination path of the system
services.
The components which are not displayed in gray (dimmed) can be deselected.
² Click Disk Usage in order to check whether sufficient free memory is available. If the memory capacity is
not sufficient, deselect components or install them on another drive.
² Click Browse in order to change the installation path for a component.
² Apply the default settings (recommended) or select the components to be installed.
² Click Next >.
Figure 3-5 Selecting the Product Mode (Licensed Version or Demo Version)
² Select Demo Mode if you have received SICAM PAS/PQS for demonstration purposes.
- or -
² Select Licensed Mode if you have purchased a full version of SICAM PAS/PQS.
If you select Licensed Mode, you can additionally specify whether you want to install a Full Server or a
DIP.
If you are using the demo version of SICAM PAS/PQS, the Full Server is installed.
² Select Full Server if your computer is a stand-alone computer or is used as a server in a distributed SICAM
PAS/PQS.
Every distributed SICAM PAS/PQS requires exactly one server.
- or -
² Select Device Interface Processor (DIP) if your computer is the DIP of a distributed SICAM PAS/PQS.
Every distributed SICAM PAS/PQS requires exactly one Full Server. The other computers in the system are
DIPs.
² Click Next >.
If you are using SICAM PAS/PQS for the first time, a configuration database does not exist and the
following dialog is not displayed.
If a database has already been installed under the specified path, the system prompts you whether the
existing database is to be retained or overwritten. If you have updated SICAM PAS/PQS and want to use
the existing database, the conversion is completed by executing the Feature Enabler.
It is possible that the database has been created using a SICAM PAS/PQS version that has previously been
uninstalled.
NOTE
i An existing SICAM PAS/PQS database of version V5.1x and later is converted to the latest version upon the
initial start-up of SICAM PAS/PQS Feature Enabler.
If you upgrade from an existing version of SICAM PAS/PQS to the latest version and select No, the database
to be opened is created with an older version of SICAM PAS/PQS. Under this condition, SICAM PAS/PQS UI –
Operation Client cannot be opened.
To open SICAM PAS/PQS UI – Operation Client:
• Click Yes.
The Report displays the progress and completion of the execution of the scripts. SICAM PAS/PQS UI –
Operation Client can now be opened successfully.
NOTE
i You can also use a different user instead of PASRuntimeUser, see 3.2.3 Using a Different User Account in
PAS Runtime.
Only the user that has been logged on to Windows during installation of SICAM PAS/PQS will automatically
be added to the SICAM PAS PQS Users group by the installer. Further Windows users that should be able
to work with SICAM PAS/PQS must be manually added to the SICAM PAS PQS Users group via Computer
Management > Local Users and Groups > Groups.
NOTE
i The password must be at least 8 characters long and must include 1 letter, 1 number and 1 special
character. Follow your corporate password policy if it mandates to contain more than 8 characters.
This password must be identical for all SICAM PAS/PQS installations that are part of the same SICAM
PAS/PQS project (for example, Full Server-DIP or redundancy relations).
The entered password will be set as the password for the already existing PASRuntimeUser user.
[sc_RBCA_FirstInstallation, 9, en_US]
When installing SICAM PAS/PQS for the first time, Windows user groups are added to provide a role-based
access control for the archive (RBAC) to perform various operations for the archive data.
If you select the RBAC check box, the RBAC gets activated and your user account is added to the SICAM PQ
Analyzer ADMIN user group with all rights.
If you do not select the RBAC check box, the user groups remain empty and any user has all the access rights
for the archive.
To change this setting, a user account or a domain user group can be manually added to the SICAM PQ
Analyzer ADMIN, SICAM PQ Analyzer ENGINEER, SICAM PQ Analyzer OPERATOR, or SICAM PQ Analyzer
VIEWER user group via Computer Management > Local Users and Groups > Groups.
For more information on RBAC, refer to /13/ SICAM PQ Analyzer.
² Click Next >.
² Click Install.
This starts the installation process. The following steps are executed:
• The installer copies the SQL Anywhere software to the hard disk and creates the database required for
the SICAM PAS/PQS software.
• The installer copies the SICAM PAS/PQS software to the hard disk.
• The installer creates the Windows Registry entries, which ensure that the SICAM PAS/PQS services (for
example, SSR, IPCDaemon, SARAMonitoring, DfAgent) starts up automatically. Additionally, the installer
customizes the system's PATH variable, creates Windows Services and program groups, inserts menu
items in the Start menu, and starts individual services.
The following dialog is displayed as soon as the installation has been completed:
² Click Finish.
After the installation, the system prompts you to restart the computer.
NOTE
i The dongle includes all the license keys ordered and enables the corresponding features. As an alternative
to a dongle you can license the system via Internet for a computer or a virtualization solution and enable it
via the Soft License, or by using the ALM license model.
In case of an upgrade or reinstallation of an existing system V8.01 or earlier (old dongle), the features must
be enabled in the Feature Enabler. For more information, see A.19 Using a Dongle to License a SICAM
PAS/PQS System, V8.01 and Earlier.
In case of an upgrade or reinstallation of an existing system V8.17 or later, ALM must be used for licensing.
For more information, see 5.2 Using Online Software Delivery (OSD) to License a SICAM PAS/PQS System,
V8.17 and Later.
Be aware of the following:
• For the operation of a Full Server, the Runtime - Small/Medium/Large function must have been
enabled.
• To configure a SICAM PAS/PQS system, the Configuration function must have been enabled.
NOTE
i During the installation of SICAM PAS/PQS, the %SR5_DATA% directory is created and enabled with full
permission for all users of the SICAM PAS PQS Users group.
The Archive Server monitoring service, Defragmentation Agent, PowerCC IPC Daemon, and SSR serv-
ices run with the PASRuntimeUser login.
SICAM PAS/PQS saves configuration data in the %SR5_DATA% directory. In order to retrieve current config-
uration data, the other SICAM PAS/PQS computers must be able to access this directory.
NOTE
i If the SSR service fails to start after restarting the computer, proceed as follows:
• Right-click the ASRBaseAddressEditor.exe application and select Run as administrator from the
context menu. You will find this application in the SICAM PAS installation folder for binary files
(%PAS_BIN%).
NOTE
i The following folders are provided security permission for the Users group with full permission:
• %commonappdata%Siemens\SettingsManager
• %commonappdata%Siemens\SICAM PQ Analyzer
After the installation on Windows 7, shortcuts for SICAM components are created in the All Programs list and
in the SICAM PAS/PQS directory.
[sc_Windows7, 4, en_US]
After the installation on Windows 8.1 or Windows Server 2012 R2, tiles/shortcuts for SICAM components are
created in the Apps window and in the SICAM PAS/PQS directory on the desktop.
[sc_Apps_Window, 2, en_US]
After the installation on Windows 10 or Windows Server 2016/2019, shortcuts for SICAM components are
created in the All Apps list in the SICAM PAS/PQS directory.
[sc_Windows10, 1, en_US]
After the installation on Windows 11, shortcuts for SICAM components are created in the All Apps list in the
SICAM PAS/PQS directory.
[sc_Windows11, 1, en_US]
After the installation on Windows Server 2022/21H, shortcuts for SICAM components are created in the All
Apps list in the SICAM PAS/PQS directory.
[sc_WindowsServer2022, 1, en_US]
NOTE
Running Setup.exe
² Open the Command Prompt with administrator rights.
NOTE
NOTE
i During the installation of SICAM PAS/PQS, if any of the installation prerequisites is not met, the installation
is aborted. Also, the prerequisite that was not met is displayed in the log file.
If you want to use a different account in PAS runtime instead of PASRuntimeUser, proceed as follows on all
SICAM PAS/PQS systems:
² Add a new account to the SICAM PAS PQS Users group.
² Log on to the account to access the following services:
To add local users and domain users to the SICAM PAS PQS Users group:
² Click Start, type Computer Management, and confirm by pressing <Enter>.
The Computer Management window opens.
² In the navigation tree, select Local Users and Groups > Groups.
[sc_Computer_Management, 2, en_US]
² Select SICAM PAS PQS Users and select Add to Group... from the context menu.
The SICAM PAS PQS Users Properties dialog opens.
[sc_User_Properties, 2, en_US]
² Click Add... .
² If you use a domain account, click Locations... in the Select Users, Computers, Service Accounts, or
Groups dialog.
[sc_Select_User_Comp_Serv_Acc_Grp, 2, en_US]
NOTE
i If you add a user to the SICAM PAS PQS Users group who is already logged on to the system, make sure
that the user logs off and logs on again to enable the changes made to user groups.
[sc_Services_Properties, 2, en_US]
[sc_SSR_Properties, 2, en_US]
If a user password is modified from the Computer Management, which is used to log on to SICAM PAS/ PQS
UI – Operation Client, the password must also be modified in the application pool of the Internet Information
Services (IIS).
To modify the password in the application pool:
² Click Start, type IIS, and confirm by pressing <Enter>.
[sc_IIS_Manager, 2, en_US]
² Right-click SiemensEnergy and select Advanced Settings... from the context menu.
The Advanced Settings dialog opens.
² Select Identity from the Process Model section and click ... .
The Application Pools Identity dialog opens.
² Select Custom account and click on Set... .
The Set Credentials dialog opens.
[sc_IIS_Maanger_Advanced_Settings, 2, en_US]
² Enter the User name and Password and click OK in all the open dialogs.
The User name and Password is set.
You can view the Product version, Installed hotfix version, and Copyright product information from the
About dialog in the Microsoft Edge web browser.
To do this, proceed as follows:
² Open SICAM PAS/PQS UI – Operation Client in Microsoft Edge and click the following symbol:
If you are unable to view the product information, change the Microsoft Edge settings as follows:
² In Microsoft Edge, click ... on the top-right corner and select Settings.
² Click View advanced settings.
² Disable the Block pop-ups option.
The Windows Firewall blocks attempts to access your system via TCP/IP or UDP/IP to protect your system
against unauthorized use. The Firewall settings must be customized to provide SICAM PAS/PQS components
access to the system while the Firewall is active.
Configure the Firewall after the installation of SICAM PAS/PQS.
NOTE
i If your computers are installed behind a corporate firewall, you are protected against access from outside
the company. In this case, you can deactivate the local Windows Firewall, and the Firewall configuration
described in the following is not required.
NOTE
i Some firewalls (for example, ZoneAlarm) prevent the establishment of connections from SICAM PAS/PQS
components to the database server. Hence, release the connection establishment for the following compo-
nents in the firewall:
• SICAM PAS/PQS
• SICAM SCC
The name of the computer on which you must configure the Firewall is indicated in the right-hand table
column. Furthermore, the reason for the configuration is indicated in this column.
Additional configuration steps are required for the following system configurations, see 3.3.3 Additional
Configurations for SICAM PAS/PQS Components:
SICAM PAS/PQS
NOTE
i If a predefined port on the SARA server (communication of SICAM PQ Analyzer/SICAM PQ Collector with the
archive) must not be opened due to internal IT security policies or is already occupied by another software,
for example, SIMATIC NET, change the port on all systems as follows:
In the SICAM PAS/PQS system:
SICAM SCC
[sc_Windows_Firewall, 3, en_US]
[sc_Allowed_Programs, 3, en_US]
[sc_Allowed_Programs_BTIServer, 3, en_US]
Opening a Port
To deactivate the blocking of a port:
² Select Advanced settings from the left section of the Windows Firewall window.
The Windows Firewall with Advanced Security window opens.
[sc_WindowsFirewall_Adv_Sec, 3, en_US]
² Select Inbound Rules from the left section and click New Rule... from the Actions section.
The New Inbound Rule Wizard dialog opens.
[sc_New_Inbound_Rule, 3, en_US]
² In the Rule Type step, select Port and click Next > .
² Configure the port as required.
² Click Finish.
The blocking of the port has been deactivated.
[sc_Inbound_rules_rule_type_custom, 2, en_US]
² In the Rule Type step, select Custom and click Next > .
² In the Program step, select All program and click Next > .
² In the Protocol and Ports step, specify the ports which you want to enable.
[sc_Inbound_rules_protocol_ports, 2, en_US]
[sc_Inbound_rule_scope, 2, en_US]
This chapter describes the additional configurations which are only required for certain system configurations.
² In the Rule Type step, select Custom and click Next >.
² In the Programs step, select All programs and select Next >.
² In the Protocol and Ports step, select ICMPv4 in the Protocol type field and click Customize... .
The Customize ICMP Settings dialog opens.
² Select Specific ICMP types and enable the options as shown in the below figure.
[sc_Customize_ICMP_Settings, 2, en_US]
NOTE
• Login to the redundant system before Update System with database copy is performed from the
main system
• If the system is in a workgroup, the service is not required, hence it will not start
Windows Services
The following services are provided by the operating system and used by SICAM PAS/PQS. Only services that
can be started/stopped are listed.
Display Name Required by Purpose
SNMP Services SICAM PQS For monitoring the archive, refer to /4/ SICAM PAS/
PQS, Configuration and Operation, chapter 5.
Workstation SICAM PAS/PQS Dependent Windows service for SSR
Network Store Interface Service SICAM PAS/PQS Dependent Windows service for SSR
IIS Admin Service SICAM PAS/PQS For SICAM PAS/PQS UI – Operation Client
4.1 Prerequisites 59
4.2 Uninstallation 59
4.1 Prerequisites
• Prior to uninstallation, create a backup copy of the SICAM PAS/PQS database.
• Always uninstall SICAM PAS/PQS using the Windows uninstallation routine and read the following instruc-
tions carefully. This prevents damage to the Windows Registry and unpredicatable problems in the
operating system.
4.2 Uninstallation
You can uninstall the SICAM PAS/PQS using either via the software management function of your operating
system or via silent uninstallation.
NOTE
i The following software components are not uninstalled during the uninstallation of SICAM PAS/PQS and
must be uninstalled separately:
• ALM
• WinPcap 4.1.3
NOTE
i If you want to install a previous version of SICAM PAS/PQS with a new password for the PASRuntimeUser
user, you must manually delete the PASRuntimeUser user and the SICAM PAS PQS Users user group
via Start > Control Panel > Administrative Tools > Computer Management > Local Users and Groups
before installation.
Silent Uninstallation
To uninstall the SICAM PAS/PQS via command prompt:
² Open the Command Prompt with administrator rights.
² Copy the Setup folder from the DVD to a preferred location onto your local computer.
² Execute the Setup.exe by using either of the following commands:
<Source>\Setup.exe /sx or <Source>\Setup.exe -sx
where: <Source> indicates the location at which the Setup folder is copied onto the local computer.
For example, E:\SICAM_PAS_PQS\Setup\Setup.exe /sx.
The system restarts automatically to complete the uninstallation.
If you want to avoid the restarting of the system, enter /noreboot as a command line argument. Restart
the system manually to complete the uninstallation.
NOTE
5.1 Introduction 62
5.2 Using Online Software Delivery (OSD) to License a SICAM PAS/PQS System, V8.17 and 63
Later
5.3 Connecting the DIP to the Full Server 64
5.1 Introduction
SICAM PAS/PQS is designed as an open and modular system whose components can be individually selected.
Using the Automation License Manager (ALM), you can enable all the functions (features), which you require
on your computer.
The different communication protocols, SICAM PAS/PQS UI – Configuration, and the Power Quality (PQ)
functions are referred to as functions (features).
If the license is missing during operation, the feature for which no license key has been found will be disabled
after 10 minutes.
If the system has been running for at least 21 days, it will run for another 14 days after the first license failure.
During this time, license errors are ignored (password mismatches are not ignored). You can configure that a
message will be transmitted to the control center in case of a license error. This ensures that you can obtain a
new set of unlimited licenses if the existing ones fail while the system is still running.
In addition, the ALM assists you in enabling functional upgrades.
NOTE
i For information regarding licensing with dongles and soft licenses, refer to chapters A.8 Licensing - General
Information and A.18 Importing the License File.
• The computer that is in use becomes defective and must be replaced by another computer (spare part)
that does not have unlimited licenses.
NOTE
i The Update system function must be carried out after installing licenses with unlimited validity.
• Click Certificate.
The certificate will be opened in your standard PDF viewer.
• Click Download.
Confirm the product disclaimer if prompted.
• Double-click SETUP.EXE.
The installation will be started.
Guided Installation
From now on, you are guided through the installation.
• Transfer the license by dragging and dropping the Transfer licenses button into the navigation bar of
the ALM.
The license key is now on your local drive.
NOTICE
The C:\AX NF ZZ7 folder contains hidden files. These files and the folder must neither be deleted, moved
nor copied. They contain data which are necessary for the licensing of your software. If you do not observe
these rules, the license may be irretrievably lost.
There is a risk of transferring a virus from the hard disk to a USB medium. You should therefore run a virus
check on your PG/PC each time you install/remove a license.
In order to exclude the risk of an irretrievable loss of your license, observe the following rules:
² If you use an optimization routine (for example, Scandisk/Defrag) that can move fix memory blocks,
only use this option once you have transferred the licenses from the hard disk to another partition/
drive/USB medium.
² When you install a license, a cluster which is marked as “defective” appears on the destination drive.
Do not attempt to restore the defective cluster.
² Do not forget to uninstall the licenses before formatting, compressing or restoring your hard-disk drive
or before installing a new operating system.
² If a back-up copy of your hard disk contains copies of licenses, these copies could possibly overwrite
and destroy the valid installed licenses when you restore your back-up data on the hard disk. In order
to prevent a valid license from being overwritten by a back-up copy, you are strongly recommended to
either remove all licenses before making a back-up copy or to exclude the C:\AX NF ZZ folder from the
back-up.
NOTE
i You can transport the licenses via a USB medium or a network. For more detailed information, refer to the
documentation of the Automation License Manager.
The OPC Server, OPC Client, and the OPC XML DA Server functions (features) must be configured in addition
to installation.
6.1 Setting up the OPC Server 66
6.2 Checking the Settings of the OPC Client 83
6.3 Setting up the OPC XML DA Server 84
NOTE
i The PASRuntimeUser is used as a default user account while configuring DCOM in the following steps.
NOTE
i In some cases you may have to reconfigure DCOM after a Windows update.
To configure DCOM:
² Click Start, type dcomcnfg and confirm by pressing <Enter>.
The Component Services window opens.
[sc_Component_Services, 2, en_US]
[sc_MyComputer_Properties, 2, en_US]
You must configure access, launch, and activation rights for DCOM, because the default settings would block
any communication within the network.
To do this, proceed as follows:
² Select the COM Security tab.
² Under Access Permissions, click Edit Limits....
[sc_Access_Perm_Edit_Limits, 1, en_US]
² For Everyone, select Allow for the Local Access and Remote Access check boxes.
² For the Distributed COM Users and the ANONYMOUS LOGON, select the same permissions.
² Click OK to confirm.
² Under Launch and Activation Permissions, click Edit Limits... .
The Launch and Activation Permission dialog opens.
[sc_Launch_and_Activation_Perm_Edit_Limits, 1, en_US]
² For Everyone, select Allow for the Local Launch, Remote Launch, Local Activation, and Remote
Activation check boxes.
² For the Distributed COM Users select the same permissions.
² Click OK to confirm.
To grant Access Permissions for a user, proceed with the following steps:
² Select the COM Security tab.
² In the Access Permissions field, click Edit Default... .
The Access Permission dialog opens.
[sc_Access_Perm_Edit_Default, 1, en_US]
Adding an User
² To add an user, for example, the PASRuntimeUser, click Add... .
The Select Users, Computers, or Groups dialog opens.
² Click Locations... .
The Locations dialog opens.
² Select the name of your computer and click OK.
The From this location text box is updated.
[sc_Select_Users_Comp_Serv_Acc_Grp, 2, en_US]
[sc_Select_Users_or_Groups, 2, en_US]
[sc_Select_Users_or_Groups_PasRuntimeUser_added, 1, en_US]
Granting Permissions
² In the Access Permission dialog, select the PASRuntimeUser from the Group or user names.
² Select Allow for the Local Access and the Remote Access check boxes.
[sc_Access_Perm_PASRuntimeUser, 1, en_US]
To grant Launch and Activation Permissions for a user, proceed with the following steps:
² Select the COM Security tab.
² In the Launch and Activation Permissions field, click Edit Default... .
The Launch and Activation Permission dialog opens.
[sc_Launch_and_Activation_Perm_Edit_Default, 1, en_US]
[sc_Launch_and_Activation_Perm_PASRuntimeUser, 1, en_US]
² To grant the launch and activation permissions for the PASRuntimeUser, click OK.
² From the My Computer Properties dialog, select the Default Properties tab.
[sc_MyComputer_Properties_OPC_Default_prop, 1, en_US]
[sc_Component_Services_OPCDA_Server, 2, en_US]
Figure 6-13 Selecting the Properties of the SIEMENS SICAM PAS OPC DA Server
[sc_OPC_DA_Properties_General, 2, en_US]
Figure 6-14 SIEMENS SICAM PAS OPC DA Server Properties Dialog – General Tab
[sc_OPC_DA_Properties_Security, 2, en_US]
[sc_OPC_DA_Launch_and_Activation_Perm_PASRuntime, 1, en_US]
² Click Add... to add the user (with access permission for the OPC Server/Client).
² Select Allow for the Local Launch, Remote Launch, Local Activation, and Remote Activation check
boxes.
² To grant launch and activation permissions for the PASRuntimeUser, click OK.
[sc_OPC_DA_Access_Perm_PASRuntime, 1, en_US]
² Click Add... to add the user (with access permission for the OPC Server/Client).
² Select Allow for the Local Access and Remote Access check boxes.
² To grant access permissions for the PASRuntimeUser, click OK.
[sc_OPC_DA_Change_Config_Perm, 1, en_US]
² Click Add... to add the user (with access permission for the OPC Server/Client).
² Select Allow for the Full Control, Read, and Special Permissions.
NOTE
Endpoints Tab
This tab includes a list of protocols and endpoints, which may be used by the OPC Client.
² No settings are required.
Identity Tab
² Select the Identity tab.
[sc_OPC_DA_Properties_Identity, 1, en_US]
² Select This User and enter the user name and password and confirm it.
² Click OK to close the dialog.
² Close the Component Services window.
NOTE
i The entered user must be added to the Distributed COM Users group.
Communication
The OPC XML DA Server and OPC XML DA Client communicate via TCP/IP.
[dw_Comm_OPCXMLDA_Server_Client, 1, en_US]
Figure 6-20 Communication between the OPC XML DA Server and the OPC XML DA Client via Ethernet
This open communication is suitable for the data exchange between the SICAM PAS/PQS and other systems
based on Microsoft Windows or also on other operating systems such as LINUX.
The OPC XML DA Server allows the exchange of structured information (station data) via the Internet using
XML (EXtensible Markup Language).
Via the OPC XML DA Server, the OPC XML DA Client can set protocol parameters and read or write all the
values, which have been mapped to OPC XML DA in SICAM PAS/PQS UI – Configuration.
The OPC XML DA Server can be accessed via http://<hostname/ipaddress>:8081/da from the OPC XML DA
Client.
The time zone information for SICAM PAS/PQS can be updated using a download from the IANA Time Zone
Database.
High-precision time synchronization is a prerequisite for the proper functioning of a SICAM PAS/PQS system. A
radio clock can be used as the timer. The time information from this clock is distributed throughout the entire
system. The distribution of time information is shown based on a sample configuration.
7.1 Updating Time Zones 86
7.2 Synchronizing Time 86
² Select the TimeZoneDataUpdater.cmd file and select Run as adminstrator from the context menu.
The command line tool opens.
² In the dialog that follows, navigate to the downloaded time zone data file and open it.
The time zone information is being updated.
² Click OK to exit the program.
After the update process is completed, the runtime system loads the time zone data within an hour. The
system does not need to be shut down or be restarted.
• an NTP clock (for example, SICLOCK, Hopf Time Server, and Meinberg Time Server), an external device
connected to the SICAM PAS/PQS computer via Ethernet
NOTE
i The Hopf FG6039GPS receiver has been discontinued. If you want to continue to use this PCI card for the
SICAM PAS/PQS computer, refer to the Installation manual of SICAM PAS/PQS V8.08.
The time synchronization of SICAM PAS/PQS is based on the NTP (Network Time Protocol) and the corre-
sponding NTPD (Network Time Protocol Daemon) software. Under a Windows operating system, the NTPD
service runs in the background. For the installation of SICAM PAS/PQS, it is referred to as the Network Time
Protocol Service. It is configured by means of the ntp.conf ASCII file. To edit this configuration file, Siemens
recommends a text editor with the YAML markup language support, for example, Notepad++. Using this
editor, comments and entries are displayed in different colors. The configuration file is located in the Windows
directory, subfolder \drivers\etc\, for example: C:\WINNT\system32\drivers\etc\.
NOTE
i Windows 7 and higher does not allow to edit the ntp.conf file directly within the Windows directory.
If you use one of these operating systems, copy the ntp.conf file to another directory (outside of the
Windows directory), for example to the desktop. Edit the copied file there and save it to the Windows
directory afterwards, overwriting the existing file.
The NTPD is automatically installed together with SICAM PAS or SICAM SCC. It is activated upon a restart of
the computer.
In a SICAM PAS/PQS system, several NTPDs are simultaneously active (for example, on the external radio clock,
the SICAM PAS/PQS, and the SICAM SCC computer). An NTPD can be configured as a Server or as a Client.
Upon the request of a Client, the Server communicates its time information to the Client.
Based on NTP, a precision of approximately 0.1 ms can be achieved under a Windows operating system. In
order to achieve this high precision, the system's NTPDs must perform extensive calculations. This process
can take several hours after the system starts. If the current Time Master fails, the NTPDs use the time data
determined in order to keep an utmost level of time precision for as long as possible.
For more detailed information on NTP, refer to http://www.ntp.org.
For the configuration of the NTPD, knowledge about its main functions is required. Some NTPD functions and
terms are illustrated below.
• High means that the system time deviates from the 'real' clock time by less than 10 ms and that the
quality of the time sources is sufficient for this determination. A dispersion of less than 10 ms is sufficient
to meet the standard requirements in the field of power automation.
• Medium means that the system time deviates from the 'real' clock time by less than 2 s and that the
quality of the time sources is sufficient for this determination. This level of precision ensures that no
low-quality time stamps are produced if a switching second is inserted and the clock therefore shows a
temporary deviation of ~1 second.
• Low means that the available time information does not have the required precision and that the system
must therefore be considered as 'out of synchronization'.
• Unknown is assigned if the system detects that no NTP service runs at all or that the service was not able
to detect a time source.
For compatibility reasons, a SICAM PAS/PQS-internal time stamp includes the ClockSync and ClockValid status
bits. These bits are set depending on the quality of the time stamp:
• High
The ClockSync and ClockValid status bits are set.
• Medium
The ClockValid status bits are set.
• Low
No status bit is set.
• Unknown
No status bit is set.
• a telecontrol protocol as a backup (in case the primary (NTP) clock source fails)
a shared memory clock driver must be used with the (basic) mode 1.
NOTE
i When using telecontrol protocols for time synchronization, a system time accuracy below 10 ms is not
ensured.
The ntp.conf configuration file consists of 4 blocks for time synchronization via telecontrol protocols. Thereby
up to 4 telecontrol contol connections can be used for time synchronization. A typical block has the following
structure:
• The 3rd address section (28) defines the type of clock driver (28 = shared memory clock driver).
• The 4th address section (0) is used to distinguish between clocks of the same type.
The values 0, 1, 2, or 3 refer the maximal 4 control center connections configured in SICAM PAS UI –
Configuration for time synchronization via telecontrol protocol.
• The expected time synchronization interval with telecontrol protocol is between 4 seconds (minpoll 2 =
22) and 64 seconds (maxpoll 6 = 26).
• The stratum value 5 specifies the time synchronization via a telecontrol protocol.
Mode
For time synchronization via telecontrol protocols the mode values 1, 17, 33, or 49 (based on the basic
mode 1) can be used.
The mode parameter must be interpreted as a bit pattern (decimal value). The tables below illustrate the
significance of the bits, for example, if bit 0 and bit 5 are set, mode 33 results from the bit pattern.
Bit 7 6 5 4 3 2 1 0
Bit pattern 0 0 1 0 0 0 0 1
Value 32 1
If SICAM PAS is under normal conditions time synchronized with NTP clocks and time synchronization via tele-
control protocol will be used as backup (when NTP synchronization fails), mode 1 or mode 33 (recommended)
shall be used.
• Mode 1
without additional functional specifications
• Mode 33
Automatic time-out monitoring is included (bit 5)
If SICAM PAS will be time synchronized only via telecontrol protocol, mode 17 and mode 49 (recommended)
can be used. Both, mode 17 and mode 49, support “Setting the clock time", that is, the clock driver immedi-
ately sets the system clock to the received value if the difference to the system time is more than 10 s
respectively the value defined with fudge time2 (bit 4 = 1).
Mode 17 specifies that “Automatic time-out monitoring” is not used (bit 5 = 0).
Minpoll, Maxpoll
If Automatic time-out monitoring (bit 5 = 1) is activated, the NTPD tries to set a polling interval within the
limits selected via minpoll and maxpoll. If the telecontrol protocol did not provide any value within a defined
interval, the polling interval is increased by one step. If more than 2 values are transmitted within an interval,
the polling interval is reduced by one step.
If synchronization based on the telecontrol protocol fails, the polling interval increases until the maximum
interval value has been reached. The clock is marked as faulty and the polling interval is set to the minimum
value in order to detect a recovery of synchronization as quickly as possible.
The values for minpoll and maxpoll must be selected in such a way that they include the expected time
synchronization interval of the telecontrol protocol. Minpoll and maxpoll are exponents referred to the basis
of 2.
The following value range can be used: minpoll = 2 (22 = 4 s) to maxpoll = 10 (210 = 1024 s = 17 min)
If mode 1 or mode 17 is used, the values for the minpoll and maxpoll parameters must be selected very
carefully in order to match the synchronization frequency of the telecontrol center: the minpoll parameter
must be set in such a way that also 2minpoll is greater than the expected time synchronization interval via
telecontrol protocol.
Fudge
• Time1
As with most clock drivers, this value is used in order to compensate a systematic (constant) offset. For
example, the runtime of the telecontrol telegram between the control center and the substation can be
corrected. The value is defined as a floating point value indicated in seconds.
Example: An offset of 1 second results in time1 1.
• Time2
The difference value for clock time setting can be increased to a value greater than 10 s, see bit 4 in the
description of mode 33, Table 7-2. The value is defined as a floating point value indicated in seconds.
Example: The value can be set to 20 seconds with time2 20.
When installing SICAM PAS/PQS or SICAM SCC, an ntp.conf configuration file is copied into the %windir%
\system32\drivers\etc or ...\%windir%\SysWow64\drivers\etc directory. The %windir% directory name
depends on the operating system, for example, Windows or WINNT. This file is used to configure the NTPD.
The Time Servers are indicated in the configuration files of the Clients. However, the Clients are not indicated
in the configuration files of the Servers. A Time Client can therefore be conveniently added to a system. Only
the configuration file of the new Client needs to be edited.
The configuration file includes some comments on its contents. This paragraph provides information about
important entries.
For more detailed information, refer to the following web site: http://www.ntp.org.
#--------------------------------------------------------------------------
# -*- SECURITY RELATED SETTINGS -*-
#--------------------------------------------------------------------------
# DRDoS attack prevention (DRDoS -> distributed reflection denial of service)
# disable monitor
# ^^^^^^^^^^^^^ -- DO NOT CHANGE UNLESS YOU KNOW WHAT YOU'RE DOING!
# The 'mrulist' command can be used for a DRDoS attack unless a firewall can
# prevent access from outside the network. (But even then, an inside attacker
# could still use the response amplification to carry out an attack.) So the
# whole monitoring feature should be disabled by default, unless specific
# access rules and authentication are provided.
General Settings
#--------------------------------------------------------------------------
# general settings
#--------------------------------------------------------------------------
# -- panic threshold --
# if system clock is more than that distance from the best external source,
# stop the service because something is really weird. Setting this to zero
# (0.0) disables all sanity checks, which is quite useful if the BIOS clock
# of the system is unreliable or some(one/thing/entity) tends to shoot the
# clock miles off...
# -- stepout threshold --
# If a clock step is required to sync the system, this condistion must be
# stable for a given amount of time (default: 900 seconds, or 15 minutes).
# The default is too long for a SICAM PAS system, so we set it to 1.5 minutes.
# setting this to 0.0 will no longer suppress popcorn spikes and is not
# recommended; only do this if you do not mind occasional unnecessary steps
# of the system clock!)
tinker stepout 90.0
# -- driftfile storage --
# NTPD will store the clock drift here, so after restart the service will
# lock the FLL/PLL faster. On embedded systems, make sure that file is
# writeable and on a non-write-protected file system!
driftfile %windir%\ntp.drift
# -- logfile storage --
# make sure this is a writeable file on a non-write protected file system!
#logfile D:\tmp\ntpd.log
#--------------------------------------------------------------------------
# make sure we operate well enough with windows and a limited number
# of clock sources. Note this also defines the stratum used if no time source
# is available/eligible for synchronisation.
#--------------------------------------------------------------------------
tos orphan 10 # stratum 10 if no clock source available
tos mindist 0.020 # allow 20ms distance in sync group
• Tinker panic
If the clock concerned deviates by more than 7200 s from the best external clock, time information is not
sychronized. The NTPD stops automatically or does not start up.
The Services Manager indicates whether the NTPD has started or not. Press <F5> to update the Services
Manager. Set the local system time manually and start the NTPD.
Reference Clocks
#--------------------------------------------------------------------------
# Reference clocks
#--------------------------------------------------------------------------
# -- local system clock
# the local system clock is used as level 10 fallback if everything fails and
# the server must continue to operate because of (S)NTP clients like
# IEC61850 devices et al.
#
# NOW OBSOLETED BY 'tos orphan 10' -- do not use this clock unless you know
# 'what you're doing! Change the 'tos orphan' line for different stratum settings.
# obsolete# server 127.127.1.0
# obsolete# fudge 127.127.1.0 stratum 10 flag2 1
Using the lines under local system clock, you can define the local clock as the timer. Define a high value for
the stratum. The local time is used unless another, better time base is available.
#--------------------------------------------------------------------------
# shared memory clocks ('iburst' is not useful here)
#--------------------------------------------------------------------------
# minpoll 2 -> 4s / maxpoll 6 -> 64s, mode 33 -> adaptive polling
# Windows 7 recommendation: minpoll 4 maxpoll 4, but do this only
# if your CC can sync the substation every 10..15 seconds;
# set the min/maxpoll of a clock to match the control center sync frequency.
# channel 1
server 127.127.28.0 mode 33 minpoll 2 maxpoll 6
fudge 127.127.28.0 stratum 5 #
# channel 2
server 127.127.28.1 mode 33 minpoll 2 maxpoll 6
fudge 127.127.28.1 stratum 5
# channel 3
server 127.127.28.2 mode 33 minpoll 2 maxpoll 6
fudge 127.127.28.2 stratum 5
# channel 4
server 127.127.28.3 mode 33 minpoll 2 maxpoll 6
fudge 127.127.28.3 stratum 5
These lines are required in order to use shared memory clock drivers. They are used for time synchronization
through telecontrol protocols.
• Mode
Through mode 33, see Table 7-2, you can define adaptive polling. During adaptive polling, the frequency
of the poll is automatically adjusted to the poll result. If the result rarely changes, polls are performed less
frequently.
• Minpoll, maxpoll
The minpoll and maxpoll parameters must be specified in such a way that the range matches the current
synchronization rate of the control center as precisely as possible.
Peers
#--------------------------------------------------------------------------
# peers: all time sync peers in a PAS installation
#--------------------------------------------------------------------------
# If the local system has reference clock access, mention all other systems
# (full servers and dips) in a PAS installation that can also access reference
# clocks. Peers will negotiate the leader of the pack...
# minpoll 2 -> 4s / maxpoll 6 -> 64s, iburst -> initial burst poll
# Windows 7 recommendation: minpoll 4 maxpoll 4
# peer xxx.xxx.xxx.xxx minpoll 2 maxpoll 6 iburst
If one Full Server and one or several DIPs are used, the synchronization sources can be distributed among the
computers used. To do this, activate the peer line.
In this case, the computers must determine among each other which clock time is most suitable. Since the
classical Server/Client relationship cannot be applied in this context, all the computers involved must be
configured as peers (that is, colleagues with the same priority). Data is exchanged on a bidirectional basis in
order to ensure that synchronization can be performed by both systems.
Servers
#--------------------------------------------------------------------------
# servers
#--------------------------------------------------------------------------
# If the local system has no reference clock access, mention all systems that
# have reference clock access here. If there is a network path to an external
# clock source (NTP server in the control center, for example) list them
# here, too. And furthermore mention all fallback servers that can be used!
# minpoll 2 -> 4s / maxpoll 6 -> 64s, iburst -> initial burst poll
# Windows 7 recommendation: minpoll 4 maxpoll 4
# server yyy.yyy.yyy.yyy minpoll 2 maxpoll 6 iburst
The following lines serve as examples for the definition of Time Servers. The information in these lines can
be used for demo purposes only. In a real environment, the user must enter the parameters for Real Time
Servers.
For system configurations with an IEC 61850 Ethernet bay bus, an external radio clock (for example,
SICLOCK, Meinberg, and Hopf) can be used as the Time Master on the Ethernet. If this clock fails or if the
quality of the time information is poor, another clock available in the system becomes the Time Master. In the
NTPD configuration files, you can define which clock is to become the new Time Master.
The NTPD is active on both SICAM PAS/PQS computers (Full Server and DIP) and on the SICAM SCC computer.
The NTPD of the radio clock is the Time Server; the NTPDs of the SICAM PAS/PQS computers are the Clients.
Additionally, time information can be transmitted from the telecontrol center.
[dw_Time_Synchronization_Ext_RadioClock, 2, en_US]
The bay devices on the IEC 61850 bus are Clients, which poll time information from the radio clock. Their
configuration is not described in the present document. For more detailed information on this topic, refer to
the documentation of the corresponding devices.
All other bay devices connected through IEC 60870-5-103 receive time information from the DIP.
Configuration Files
This paragraph provides a list of the ntp.conf configuration files for the SICAM PAS/PQS and the SICAM SCC
computer. The entries in the list have been customized for the example illustrated. Be aware that the real
system configuration (for example, IP addresses) of your own environment must be considered.
Changes to the predefined configuration files have been highlighted.
#--------------------------------------------------------------------------
# -*- SECURITY RELATED SETTINGS -*-
#--------------------------------------------------------------------------
# DRDoS attack prevention (DRDoS -> distributed reflection denial of service)
# disable monitor
# ^^^^^^^^^^^^^ -- DO NOT CHANGE UNLESS YOU KNOW WHAT YOU'RE DOING!
# The 'mrulist' command can be used for a DRDoS attack unless a firewall can
# prevent access from outside the network. (But even then, an inside attacker
# could still use the response amplification to carry out an attack.) So the
# whole monitoring feature should be disabled by default, unless specific
# access rules and authentication are provided.
#--------------------------------------------------------------------------
# general settings
#--------------------------------------------------------------------------
# -- panic threshold --
# if system clock is more than that distance from the best external source,
# stop the service because something is really weird.
tinker panic 7200.0
# -- driftfile storage --
# NTPD will store the clock drift here, so after restart the service will
# lock the FLL/PLL faster. On embedded systems, make sure that file is
# writeable and on a non-write-protected file system!
driftfile %windir%\ntp.drift
# -- logfile storage --
# make sure this is a writeable file on a non-write protected file system!
#logfile D:\tmp\ntpd.log
# -- Statistic file storage --
# make sure this is a directory on a non-write protected file system!
#statsdir D:\tmp\ntpstats\
#--------------------------------------------------------------------------
# reference clocks
#--------------------------------------------------------------------------
# -- local system clock
# the local system clock is used as level 10 fallback if everything fails and
# the server must continue to operate because of (S)NTP clients like
# IEC61850 devices et al.
server 127.127.1.0
fudge 127.127.1.0 stratum 10
#--------------------------------------------------------------------------
# shared memory clocks ('iburst' is not useful here)
#--------------------------------------------------------------------------
# minpoll 2 -> 4s / maxpoll 6 -> 64s, mode 33 -> adaptive polling
# channel 1
server 127.127.28.0 mode 33 minpoll 2 maxpoll 6
fudge 127.127.28.0 stratum 5
# channel 2
server 127.127.28.1 mode 33 minpoll 2 maxpoll 6
fudge 127.127.28.1 stratum 5
# channel 3 server 127.127.28.2 mode 33 minpoll 2 maxpoll 6
fudge 127.127.28.2 stratum 5
# channel 4
server 127.127.28.3 mode 33 minpoll 2 maxpoll 6
fudge 127.127.28.3 stratum 5
#--------------------------------------------------------------------------
# peers: all time sync peers in a PAS installation
#--------------------------------------------------------------------------
# If the local system has reference clock access, mention all other systems
# (full servers and dips) in a PAS installation that can also access reference
# clocks. Peers will negotiate the leader of the pack...
# minpoll 2 -> 4s / maxpoll 6 -> 64s, iburst -> initial burst poll
peer 192.168.1.6 minpoll 2 maxpoll 6 iburst
The SICAM PAS/PQS DIP must be entered as a peer for the radio clock. If this is not possible, the radio clock
must not be used as a peer, but as the Server.
#--------------------------------------------------------------------------
# servers
#--------------------------------------------------------------------------
# If the local system has no reference clock access, mention all systems that
# have reference clock access here. If there is a network path to an external
# clock source (NTP server in the control center, for example) list them
# here, too. And furthermore mention all fallback servers that can be used!
# minpoll 2 -> 4s / maxpoll 6 -> 64s, iburst -> initial burst poll
server 192.168.1.6 minpoll 2 maxpoll 6 iburst
Configuration file of the SICAM SCC computer and of the SICAM PAS/PQS Full Server
#--------------------------------------------------------------------------
# general settings
#--------------------------------------------------------------------------
# -- panic threshold --
# if system clock is more than that distance from the best external source,
# stop the service because something is really weird.
tinker panic 7200.0
# -- driftfile storage --
# NTPD will store the clock drift here, so after restart the service will
# lock the FLL/PLL faster. On embedded systems, make sure that file is
# writeable and on a non-write-protected file system! driftfile %windir%\ntp.drift
# -- logfile storage --
# make sure this is a writeable file on a non-write protected file system!
#logfile D:\tmp\ntpd.log
# -- Statistic file storage --
# make sure this is a directory on a non-write protected file system!
#statsdir D:\tmp\ntpstats\
#--------------------------------------------------------------------------
# reference clocks
#--------------------------------------------------------------------------
# -- local system clock
# the local system clock is used as level 10 fallback if everything fails and
# the server must continue to operate because of (S)NTP clients like
# IEC61850 devices et al.
server 127.127.1.0
fudge 127.127.1.0 stratum 10
#--------------------------------------------------------------------------
# shared memory clocks ('iburst' is not useful here)
#--------------------------------------------------------------------------
# minpoll 2 -> 4s / maxpoll 6 -> 64s, mode 33 -> adaptive polling
# channel 1
server 127.127.28.0 mode 33 minpoll 2 maxpoll 6
fudge 127.127.28.0 stratum 5
# channel 2
Using the VMware software, several different SICAM PAS/PQS versions can be operated in parallel on the same
computer.
A substation or a SIMEAS R device can be connected to SICAM PAS/PQS by means of a dial-up connection. The
SICAM PAS/PQS computer must be equipped with a modem in this case.
A.1 Several SICAM PAS/PQS Versions on One Computer 99
A.2 Virtualization Solutions 100
A.3 Connecting a Substation via IEC 60870-5-101 102
A.4 Connecting a SIMEAS R Device 107
A.5 Modem (TAPI Interface) 108
A.6 Modem via COM Port (Hayes Compatible) 120
A.7 Working with the Multilanguage Manager Tool 125
A.8 Licensing - General Information 127
A.9 Feature Enabler 128
A.10 Using a Dongle for Licensing 130
A.11 Using a Soft License for Licensing 130
A.12 Software Licensing - General Information 130
A.13 Licensing a System with Internet Access 131
A.14 Licensing a System without Internet Access 134
A.15 Extending a System with Internet Access 139
A.16 Extending a System without Internet Access 140
A.17 Extending a Dongle via Internet 142
A.18 Importing the License File 143
A.19 Using a Dongle to License a SICAM PAS/PQS System, V8.01 and Earlier 144
A.20 Connecting the DIP to the Full Server 147
NOTE
i The installation of two SICAM PAS/PQS versions may only be performed on a computer which is used
exclusively for the configuration of SICAM PAS/PQS systems.
VMware 5.x (or higher) enables you to operate several virtual computers ("virtual engines") on one single
computer. Each virtual computer behaves like an autonomous computer with an individual audio/video and
network interface card and an individual hard disk. You can switch between the virtual computers by clicking
the mouse button.
Set up a virtual computer in order to operate 2 SICAM PAS/PQS versions (for example, SICAM PAS V7.00 and
SICAM PAS/PQS V8.04) in parallel. On the real computer (with host operating system), install SICAM PAS/PQS
V8.04; on the virtual computer (with guest operating system), install SICAM PAS V7.00. Alternatively, you can
install both SICAM PAS/PQS versions on 2 virtual computers.
NOTE
i For the virtual computer, you may only use the operating systems which have been released for SICAM
PAS/PQS (see 2.2 Operating System).
Since the use of special PC communications cards (CP5613/14, USB) is not supported by VMware 5.x, only the
SICAM PAS/PQS UI – Configuration and Feature Enabler components can be executed. In order to ensure
that the SICAM PAS/PQS UI – Operation and Value Viewer components and the Runtime operate properly,
standard COM interfaces should be used.
Virtual Computer
VMware supports the following 3 different variants of virtual computers:
• VMware Workstation
• VMware Server
With the VMware Server, the virtual computer is accessed via the VMware Console.
• VMware Player
With the VMware Player, you can only run an existing virtual computer. However, you can neither create
a new virtual computer nor modify an existing one, because the VMware Player has not been designed
for these purposes.
In order to be able to execute the steps described below, the VMware Workstation must have been installed
according to the corresponding instructions. Additionally, an operating system released for SICAM PAS/PQS
(see 2.2 Operating System) is installed.
[sc_VMware_workstation_start, 1, en_US]
For more detailed information on the settings, refer to the VMware online help.
• Set the CD ROM to Auto detect in order to ensure that the virtual computer can use the DVD drive.
• Set the USB Controller to Present if you are using the USB dongle.
• Insert a parallel port if you are using a dongle for the parallel interface.
NOTE
i You can install both the Full Server and a DIP on a virtual computer.
NOTE
• In addition to the application software, the Virtual Delivery Agent (VDA) must be installed on every
virtual machine.
Licensing
Every guest system must be treated like a real installation and licensed accordingly.
A dongle (licenses) must be purchased for every virtual machine. The licenses must be specifically assigned to
an individual virtual machine. To achieve this, a USB hub must be used. The USB hub and the virtual machine
are connected via Ethernet LAN. In order to be able to assign a virtual machine a USB port, the USB hub
must first be configured via the web interface of the hub. Furthermore, the software providing access to the
corresponding USB ports (port groups) must be installed on every virtual machine which is to connect to the
USB hub. The USB devices plugged into the ports communicate with the corresponding virtual machine via
Ethernet LAN.
Please note that the dongles must be redundantly connected (via at least two USB hubs) in a redundant
configuration.
NOTE
i Prolonged network failures may cause the applications to stop working. To restart them, update the
system.
Restrictions
SICAM PAS/PQS does NOT support multi-user scenarios (i.e. the simultaneous use of the product) on a virtual
machine.
NOTE
i Especially when using virtual solutions in a redundant configuration, the fail-safe operation of core compo-
nents such as network cards or hard disks must be ensured so as not to impair the availability of the overall
system.
[dw_Config_IEC60870-5-101_Protocol, 2, en_US]
In such a configuration, the substation can be communicate with SICAM PAS/PQS through a serial connection
(COM port) using either a dedicated line or a dial-up connection (via modem).
If a modem connection is used, the modem must have already been installed on the SICAM PAS station
computer. Modems can be installed via the Windows Control Panel.
The following modems can be used:
• Analog modem
• GSM modem
NOTE
i Check that a modem driver for your operating system is available, before you buy a modem.
Installing a Modem
To install a modem for an IEC 60870-5-101 interface under Windows 10:
² Click Start, type Phone and Modem, and confirm by pressing <Enter>.
The Phone and Modem dialog opens.
² Select the Modems tab.
[sc_Add_Modem, 2, en_US]
² Click Add....
The Add Hardware Wizard dialog opens.
[sc_Install_Modem, 2, en_US]
² Activate Don't detect my modem; I will select it from a list and click Next >.
² In the next dialog, click Have Disk....
The Install From Disc dialog opens.
[sc_Install_From_Disk, 1, en_US]
NOTE
² In the Install from Disk dialog, confirm your selection with OK.
² Select your modem (ISDN or analog modem) from the Manufacturer and Models sections.
[sc_Select_Modem, 2, en_US]
NOTE
i Configure the modem connection of the substation/miniRTU in such a way that the INSYS modem uses the
same data protocol as the modem on the SICAM PAS computer.
In the example above, the data protocol is V.110. In this case, the configuration string e.g. of an ISDN
modem would be: ATE0&KS0=1&C1&D2V1X0B0N4&WZ (the most important value is B0, because it
defines the type of protocol).
The configuration string must be modified accordingly if an analog modem is used (refer to the operating
instructions of the analog modem).
The following applies for the selection of the protocol:
Connect 2 ISDN modems based on the X.75 protocol. In the configuration string of the INSYS ISDN TA
modem, the value B0 changes to B10.
Connect an ISDN modem to a GSM modem based on the V.110 protocol.
[sc_Modem_List, 2, en_US]
NOTE
i The AVM ISDN CAPI driver is only supported on the 32-bit edition of Windows 7.
The installation of the driver and of the virtual modem is described in detail in the card manufacturer’s
installation manual included in the scope of delivery of the ISDN card.
When installing the driver, you can select from numerous installable virtual modems.
For use under SICAM PAS/PQS, Siemens recommends you install modems working with the X.75 protocol,
such as:
NOTE
i If the ISDN card is also used by other programs, these programs must be disabled before SICAM PAS/PQS
communicates via this card. Otherwise, they might cause communication problems.
• LAN
Dial-up connection via modem
– Hayes Compatible, Baud rate up to 115 200 bit/s
– TAPI Interface, Baud rate up to 115 200 bit/s
The following modems can be used:
• Analog modem
• ISDN modem
• GSM modem
The ISDN/GSM modems must support the Hayes command set.
If you configure a modem (TAPI interface), Siemens recommends the use of an external analog INSYS Modem
56k 4.2 for both the SIMEAS R device and the SICAM PAS/PQS station computer.
[dw_Modem_Connection, 1, en_US]
Figure A-7 Dial-up Connection via Modems and the Public Telephone Network
In order to ensure reliable communication, the modems of the SIMEAS R device and the SICAM PAS/PQS
station computer must use the same INIT string and the same baud rate.
The steps to be carried out in order to set up a dial-up connection via modems are described depending on
the interface type:
• Installing the Modem on the SICAM PAS/PQS Station Computer, Page 108
[sc_Add_Modem, 2, en_US]
² Click Add....
The Add Hardware Wizard dialog opens.
² Activate Don't detect my modem; I will select it from a list and click Next >.
[sc_Install_Modem, 2, en_US]
[sc_Install_From_Disk, 1, en_US]
² In the Install from Disk dialog, confirm your selection with OK.
² Select INSYS_SimeasR from the Manufacturer´s section and INSYS Modem 56k from the Models
section.
[sc_Select_Modem_Model, 2, en_US]
[sc_Modem_List_New, 2, en_US]
[sc_Modem_Properties, 2, en_US]
² Select the INSYS Modem 56k modem and select Properties from the context menu.
The INSYS Modem 56k Properties dialog opens.
[sc_Modem_Properties_Advanced, 2, en_US]
[sc_Change_Modem_Preferences, 2, en_US]
[sc_Modem_Parameters, 2, en_US]
NOTE
i If the modem/ISDN card is also used by other programs, these programs must be disabled before SICAM
PAS/PQS communicates via this card. Otherwise, these programs might cause communication problems.
[sc_Insert_System_Resource_TAPI, 1, en_US]
Inserting an Interface
² Select the SIMEAS R Master application and from the context menu, insert an interface for the modem.
[sc_Interface_Parameters_Definition_TAPI, 2, en_US]
NOTE
i The definable Baud rate depends on the individual modem and the transmission line type.
[sc_Device_Parameters_Definition_TAPI, 1, en_US]
² Under Communication parameters, enter the Phone number under which the SIMEAS R device can be
contacted later.
[sc_PCMCIA_Interface_Definition, 1, en_US]
² Enter the Telephone number under which the SIMEAS R modem can be contacted.
This phone number is for information purposes only.
² Define the Baud rate 38400.
The baud rate must be identical with the baud rate of the modem of the SICAM PAS/PQS station
computer.
² Enter the INIT string AT&FQ0V1E0X0S0=1.
The individual elements of the INIT string have the following meaning:
AT: Attention - Start of each command sequence
&F: Loading the factory default settings - the following elements can overwrite the factory default
settings
Q0: Modem messages are reported
V1: Modem returns text messages in long form, such as "Connect" or "OK"
E0: Echo off – does not return received AT commands (no mirroring)
X0: Blind dialing – does not consider dial tone
S0=1: Use the first ring to start the establishing of the connection. The value must be greater than or
equal to 1, otherwise the SIMEAS R device does not establish a connection.
² Enter ^M as Commandsuffix.
^M stands for <CR>.
² Click OK to close the dialog.
² Load the set of parameters into the device via the Parameterset > Send to device... menu item.
² Close SIMEAS R PAR.
NOTE
i Connect the external modem to the SIMEAS R device at the place of destination and restart it. The modem
is initialized during the restart.
[sc_Insert_System_Resource, 2, en_US]
Inserting an Interface
² Select the SIMEAS R Master application and from the context menu, insert an interface for the modem.
[sc_Interface_Parameters_Definition, 2, en_US]
NOTE
i The definable Baud rate depends on the individual modem and the transmission line type.
[sc_Device_Parameters_Definition, 2, en_US]
² Under Communication parameters, enter the Phone number under which the SIMEAS R device can be
contacted later.
[sc_Data_Interface_Definition, 1, en_US]
² From the Serial communication type list box, select External modem.
² Enter the Telephone number under which the SIMEAS R modem can be contacted.
This phone number is for information purposes only.
² Define the Baud rate 38400.
The baud rate must be identical with the baud rate of the modem of the SICAM PAS/PQS station
computer.
² Enter the INIT string AT&FQ0V1E0X0S0=1 .
The individual elements of the INIT string have the following meaning:
AT: Attention - Start of each command sequence
&F: Loading the factory default settings - the following elements can overwrite the factory default
settings
Q0: Modem messages are reported
V1: Modem returns text messages in long form, such as "Connect" or "OK"
E0: Echo off – does not return received AT commands (no mirroring)
X0: Blind dialing – does not consider dial tone
S0=1: Use the first ring to start the establishing of the connection. The value must be greater than or
equal to 1, otherwise the SIMEAS R device does not establish a connection.
² Enter ^M as Commandsuffix.
^M stands for <CR>.
² Click OK to close the dialog.
² Load the set of parameters into the device via the Parameterset > Send to device... menu item.
² Close SIMEAS R PAR.
NOTE
i Connect the external modem to the SIMEAS R device at the place of destination and restart it. The modem
is initialized during the restart.
• Open the Multilanguage Manager tool, refer to Starting the Multilanguage Manager Tool, Page 126.
• Create a new language repository by using the existing reference language and make the necessary
changes in the target language.
• Copy the repository to all computers (Full Server, DIPs, redundant systems).
Installation
The Multilanguage Manager tool is installed along with the installation of SICAM PAS/PQS or SICAM PQ
Analyzer.
NOTE
i The Multilanguage Manager tool needs no licensed version of SICAM PAS/PQS. However, to create a project
for checking the translation, SICAM PAS/PQS must be installed as demo version or as licensed version.
Modified
Error
Translated
The repository is saved to a file with .LRP format. The default name for the repository is <product
name>_<product version>_<new language name>_<new language locale>.LRP.
The default storage location is %publicdocuments%Siemens\LanguageRepositories.
NOTE
i You can open the existing repository for an upgrade when the reference language is available in the
installed directory and the operating system supports the locale of the repository.
The upgrade repository operation is product specific. For example, you can upgrade the repository created
from an earlier version of SICAM PAS only if the latest version of SICAM PAS is installed on the system. To
upgrade an earlier translated version to the current version, open the repository for an upgrade and save it
with the default name or with the new name.
NOTE
i Before you deploy the language repository, close all the SICAM system components on the target system.
For deploying the language files to the installed product, you must run the tool as an administrator.
Ensure that the deployed language is same in Full Server, DIPs, and the redundant system.
• Soft License
Dongle
For the basic system (licensed version) you require a dongle which enables optional features via license keys.
These license keys only apply to a single dongle. If you purchase several SICAM PAS/PQS you receive a separate
kit including one dongle for each computer together with the corresponding license keys.
Before SICAM PAS/PQS software components start up they verify that the license key you entered matches the
information in the dongle. During operation the system checks at regular intervals whether the dongle is still
present.
If the dongle is missing or removed during operation, the feature for which no license key has been found will
be disabled after approximately 5 minutes.
If the system has been running for at least 21 days it will run for another 14 days after the first dongle failure.
During this time, dongle errors are ignored (password mismatches are not ignored). You can configure that a
message will be transmitted to the control center in case of a dongle error. This ensures that you can order a
new dongle if the existing one fails while the system is still running.
Soft License
A computer or a virtualization solution is defined by a license status and the desired features are enabled and
licensed for the system in combination with a product key.
The Soft License only applies to 1 system.
• Enabling the system with all features when using a Soft License
[sc_Feature_Enabler_soft_license, 2, en_US]
NOTE
i When ordering additional features, you must specify the Key ID.
NOTE
i For a distributed SICAM PAS/PQS system you must connect the DIP to the Full Server before enabling
features on a DIP, see A.20 Connecting the DIP to the Full Server.
NOTE
i If you use the OPC Client feature you must define further settings after the installation of your features.
For more detailed information see 6.2 Checking the Settings of the OPC Client and 6.3 Setting up the OPC
XML DA Server.
NOTE
i Since version V8.07, the Runtime – Large feature is limited to the use of 180 devices. The Runtime –
Extra Large feature is required for a system configured for more than 180 devices. When performing an
upgrade, the new Runtime – Extra Large feature is enabled instead of the Runtime – Large license.
NOTE
i With each extension of the license the counting index at the end of the file name is incremented by 1.
The license files must be imported without any gap in ascending order.
² Enable additional features in the Feature Enabler, see A.18 Importing the License File.
The dongle is extended by the imported features.
NOTICE
Changing the computer configuration during the licensing process of the soft-license
The soft license becomes invalid.
² Once the licensing process has been started, do not perform any changes to the SICAM PAS/PQS
computer which is to be licensed. This means, for example, that you must neither change any
hardware, nor install any software, nor store/restore a backup file, before the license file has been
imported via the Feature Enabler.
The system is enabled via the SICAM PAS/PQS Soft License Manager when entering the product key.
If the system is not connected to the Internet, it is defined by a license status file (C2V file). The features are
enabled on a computer connected to the Internet.
The license file (V2C file) generated when enabling the features is imported in the SICAM PAS/PQS Feature
Enabler. The system features are now enabled.
NOTE
i Contact Customer Support Center in case the installed soft license needs to be transferred to another
system.
NOTE
i The license status file includes the fully qualified domain name (FQDN) of the specific computer for which
you activate your system. Once the product key has been activated and the hostname or the domain name
is changed afterwards, the soft license becomes invalid.
Opening the SICAM PAS/PQS Soft License Manager on a Computer with the System Installed
Start the SICAM PAS/PQS – Soft License Manager tool from the Windows Start menu:
² Select Start and scroll through the app list.
² Select SICAM PAS/PQS > Tools.
The Tools folder opens.
² Double-click Soft License Manager.
The SICAM PAS/PQS – Soft License Manager tool opens.
Opening the SICAM PAS/PQS Soft License Manager on a Computer without the System Installed
The Soft License Manager with the online help is located in the root directory of the SICAM PAS/PQS DVD in
the SoftLicenseMgr directory.
² Copy the SoftLicenseMgr directory on the computer without a SICAM PAS/PQS installation.
² Open the SoftLicenseMgr directory and double-click the SoftLicenseMgr.exe file.
The Soft License Manager opens and the online help is available.
[sc_SLM_PAS_installed, 1, --_--]
[sc_confirm_activation, 1, en_US]
² Check the name of the computer for which you want to activate the product key.
The activation can neither be undone nor transferred.
The Save the activation file dialog opens after the activation.
[sc_save_V2C_online, 3, en_US]
[sc_system_activated_online, 3, --_--]
• Creating a license status file for the system to be licensed (destination system)
• Activating the product key for the destination system on a computer with Internet access
• Enabling the features on the destination system using the Feature Enabler
[sc_create_C2V, 2, --_--]
[sc_save_C2V, 2, en_US]
NOTE
i The C2V license status file is required in order to extend the Soft License on the computer with Internet
access.
[sc_SLM_PAS_not_installed, 1, --_--]
NOTE
i If SICAM PAS/PQS is installed on the computer on which you perform the activation, activate the Activate
SICAM PAS/PQS for a different machine checkbox.
² Click ... to go to the C2V license status file on the destination system.
[sc_select_C2V, 2, en_US]
The Activate button is enabled once the product key has been entered completely and the C2V license status
file has been selected.
² Click Activate.
The Save the activation file dialog opens after the activation.
[sc_save_V2C_offline, 2, en_US]
[sc_system_activated_offline, 2, --_--]
NOTE
i The V2C license file is required on the target computer in order to enable the features in the Feature
Enabler.
• Creating a license status file for the system to be extended (destination system)
• Updating the Soft License for the destination system on a computer with Internet access
• Enabling the features on the destination system using the Feature Enabler
[sc_Update_save_C2V, 1, en_US]
NOTE
i The C2V license status file is required in order to extend the Soft License on the computer with Internet
access.
NOTE
i If SICAM PAS/PQS is installed on the computer on which you perform the activation, activate the Activate
SICAM PAS/PQS for a different machine checkbox.
² Click ... to go to the C2V license status file of the destination system.
[sc_Update_select_C2V.tif, 1, en_US]
² Click Open.
The Key ID of your system is displayed.
[sc_Update_C2V_selected_KEY_ID_displayed, 1, --_--]
Figure A-37 Updating, License Status File Selected and Key ID Displayed
² Click Update.
Once the Soft License has been updated, the Save the activation file dialog opens.
² Save the V2C license file with a unique name.
A message informs you that the Soft License has been successfully updated.
NOTE
i The V2C license file is required on the target computer in order to enable the features in the Feature
Enabler.
² Plug the dongle into the computer on which SICAM PAS/PQS is installed.
² Open the Soft License Manager.
[sc_FeatureEnabler_Installed_Licenses, 2, en_US]
² Click Import... .
² Navigate to the directory in which the V2C license file is stored.
² Select the V2C license file.
[sc_Select_License_File, 1, en_US]
NOTE
i Since version V8.07, the Runtime – Large feature is limited to the use of 180 devices. The Runtime –
Extra Large feature must be used for a system configured for more than 180 devices.
To run a large system, enable the Runtime – Extra Large feature by entering the Runtime – Large license
key from the license card or from the exported license key file.
[sc_FeatureEnabler_Select_Features, 2, en_US]
² Under License key enter the license key which you have received for the selected feature. Next, click
Install.
² Repeat these two steps for all the features which you want to enable.
² As soon as you have enabled all desired features click Exit to exit the Feature Enabler.
[sc_Export_License_Key, 2, en_US]
² Click Save.
The export of the license keys is logged in the Export license keys dialog.
² Click OK to confirm the export.
² Exit the Feature Enabler.
All license keys are stored in the license key file in the specified directory and can be imported for the same
dongle.
NOTE
i The license key for an unlimited number of devices (Runtime – Extra Large) cannot be imported and must
be entered separately.
[sc_SICAMPAS_Server_Connection, 2, en_US]
² Enter the Computer name and the IP address of the computer on which the Full Server to be connected
to the DIP is running.
² Click OK.
The Feature Enabler opens and displays the features enabled on the DIP.
[sc_FeatureEnabler, 2, en_US]
² If you want to connect the DIP to another Full Server, click Database... .
NOTE
i Be aware of the following in order to ensure that all the SICAM PAS/PQS computers within a system can
access the current configuration data:
• The user who performs the system update must have a user account on each SICAM PAS/PQS
computer.
• This user must have read and write rights for the C:\Siemens\SySrv\Data directory.
/20/ SICAM P850/P855 7KG85xx V2.60, Power Monitoring Device and Power Quality Recorder, Device Manual
E50417-C1076-C482-A8
/21/ SICAM Q100 7KG95xx V2.10, Power Monitoring Device and Class A Power Quality Recorder, Device Manual
E50417-H1076-C522-A7
/22/ SICAM Q200 7KG97 V2.40, Multifunctional Recorder, Device Manual
E50417-H1040-C606-A7
/23/ SIPROTEC 5 7KE85 V7.80 and later, Fault Recorder, Manual
C53000-G5040-C018-6
/24/ SICAM GridPass V1.30, Manual
E50417-H8940-C598-A5
/25/ SIMATIC HMI WinCC V7.5, WinCC Information System, System Manual
Printout of the online help, 09/2018, A5E46376856-AA
/26/ SICAM Q80 Power Quality Recorder, System Manual
E50417-H1076-C420-A2
C N
Communication Network Operation 14
with OPC XML DA 84 Network Time Protocol Daemon 87
Configuration file NTP clock 86
ntp.conf 90 ntp.conf 90
NTPD 87
D
O
Demo version 9
Device Interface Processor (DIP) 9 Offset 87
Discontinuation 16 OPC Client
Dispersion 87 SSR 66, 83
Distributed system 9 OPC XML DA Client 84
OPC XML DA Server 84
Options
Enabling 128
F OSCOP P 16
H
Hardware components 12 R
Remote terminal interface
Time synchronization 86
I
Installation
Language selection 19 S
Product selection 19
Sequence of installation 18 Shared-Memory Clock Driver 88
Installation Variants 9 SICAM PAS CC / SICAM SCC 15
Installing a Modem 102 SICAM PAS/PQS
Options 128
several versions on one PC 99
uninstalling 59
L SICAM PAS/PQS Full Server 9
Specifying 64, 147
Licensed version 10 SICAM PQ Analyzer 15
SICAM PQS NeQual Converter 16
T
Time synchronization
Quality 87
U
Uninstallation
SICAM PAS/PQS software 59
Using an ISDN card 106
V
Virtual computer 99