Canon Service Bulletin COPIER
Issued by Canon Europa N.V.
Model: Ref No.:
iR6800C iR6800C-010
iR6800CN
(F2-T01-0M3-10027-01)
Date:
30-07-04
Location:
Vertical Size Detection Kit Installation
Subject:
Remedy Against the Glare of Scanning Lamp
Background
Reports of users complaining about the glare of the scanning lamp have been filed, and a vertical size sensor kit (AB/
Inch) will be offered as a remedial kit.
Vertical Size Sensor Kit (AB) FM2-0646
Vertical Size Sensor Kit (Inch) FM2-0647
Overview
The use of a reflection type size sensor in both main and sub scanning directions will eliminate the need for the
machine to execute size detection using its CCD, thus permitting the detection of original size without having to turn
on the scanning lamp.
It is important that the user be fully informed of the following changes in regard to detection size. Moreover, the
installation of the vertical size sensor kit (Inch; FM2-0647) calls for upgrading the reader controller software to
version 9.02 (iR C6800 Series) or later.
AB-Configuration
Inch-Configuration
Size Detection by a B6、B5R、A5、A4R、 STMT-R、STMT、LTR-
CCD B5、B4、A4、A3 R、LEGAL、LTR、
11"×17”
(279mm×432mm)
Size Detection by a B5R、A4R、B5、B4、 LTR-R、LEGAL、LTR、
Reflection Type A4、A3 11"×17”
Sensor (279mm×432mm)
(1/10)
Downloaded from www.Manualslib.com manuals search engine
iRC6800-010
Note:
As opposed to the use of a CCD, the use of a reflection type sensor will not permit detection of the following: for
AB-configuration, absence of paper, B6, A5; for Inch-configuration, absence of paper, STMT, STMT-R.
Installation Procedure
When installing the Vertical Size Sensor Kit (Inch; FM2-0647), be sure to upgrade the reader controller software
to version 9.02 or later (iR C6800 Series).
1.Check the contents of the kit.
[1] [2]
[3] [4] [5]
F-1
[1] Vertical size sensor unit.......................1 pc.
[2] Horizontal size sensor..........................1 pc.
[3] Clamp ..........................................5 pc.
[4] Edge saddle.....................................1 pc.
[5] RS tightening screw (M4x8)..................... 1 pc.
(2/10)
Downloaded from www.Manualslib.com manuals search engine
iRC6800-010
2.Installation
2.1 Installing to the Host Machine
Be sure to go through the following in strict sequence before starting the work:
1. Turn off the control panel power switch [1].
2. Turn off the main power switch [2].
3. Disconnect the power cable [3] from the power outlet.
[2]
OFF
[1] OFF
ON/OFF
[3]
F-2
1) Remove the 2 screws, and detach the right glass retainer [2]; then, detach the copyboard glass [3].
[1]
[1]
[3]
[3]
[2]
[2]
F-3
(3/10)
Downloaded from www.Manualslib.com manuals search engine
iRC6800-010
2) Remove the 2 screws [1], and detach the reader unit right cover [2].
[2]
[1]
F-4
3) Remove the 9 screws [1], and detach the CCD unit cover [2].
[1]
F-5
[1]
[1]
[2]
F-6
(4/10)
Downloaded from www.Manualslib.com manuals search engine
iRC6800-010
4) Remove the 3 screws [1].
[1]
[1]
F-7
5) Lift the original size detection unit [1] slightly;then, disconnect the connector [2].
[1]
[2]
F-8
(5/10)
Downloaded from www.Manualslib.com manuals search engine
iRC6800-010
6) Mount the included horizontal size sensor [1] to the original size detection unit [2].
Note:
Pay attention to the location of mounting, as it differs between AB-configuration and Inch- configuration.
- AB-Configuration
[1]
[2]
F-9
- Inch-Configuration
[1]
[2]
F-10
(6/10)
Downloaded from www.Manualslib.com manuals search engine
iRC6800-010
7) Fit the harness [1] to the connector [2].
- AB-Configuration
[2]
[1]
F-11
- Inch-Configuration
[2]
[1]
F-12
8) Secure the original size detection unit [1] in place using 3 screw [2].
[1]
[1]
F-13
(7/10)
Downloaded from www.Manualslib.com manuals search engine
iRC6800-010
9) Secure the vertical size sensor unit [1] in place using a screw [2].
[2] [1]
F-14
10) Fit the included clamp [1] into the hole [2].
There are multiple holes. Be sure to use the correct hole. (Do not use the hole identified as [3].)
[3]
[1]
[2]
[1]
[2]
[3]
F-15
(8/10)
Downloaded from www.Manualslib.com manuals search engine
iRC6800-010
11) Fit the included edge saddle [1] as shown.
[1]
F-16
If an edge saddle already exists, skip this step.
12) Fix the harness [1] in place using 5 clamps [2] and the edge saddle [3].
[3]
[2]
[1]
F-17
(9/10)
Downloaded from www.Manualslib.com manuals search engine
iRC6800-010
13) Route the harness [1] through the original size detection unit [2]; then, connect it to the connector [3].
[1]
[2] [3]
F-18
14) Mount the CCD unit cover, copyboard glass, right glass retainer, and reader right coverby following the steps
used to detach them but in reverse.
15) Connect the power cable to the power outlet, and turn on the main power switch.
16) Set '1' to the following service mode item: COPIER>OPTION>BODY>SZDT-SW (Category2); then, turn off
and then on the main power.
17) Check to make sure that the size of originals is correctly identified without the scanning lamp going on.
(10/10)
Downloaded from www.Manualslib.com manuals search engine