0% found this document useful (0 votes)
56 views28 pages

Electirc Wire2

The document outlines various types of PVC insulated cables and wires, including specifications for their construction, usage, and technical data. It details the rated voltage, temperature limits, and resistance characteristics for different cable types, such as fixed laying cables and flexible wires. The document serves as a technical reference for Zhengzhou Zoom Link Cable Co., Ltd.'s product offerings in electrical wiring solutions.

Uploaded by

48711905
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views28 pages

Electirc Wire2

The document outlines various types of PVC insulated cables and wires, including specifications for their construction, usage, and technical data. It details the rated voltage, temperature limits, and resistance characteristics for different cable types, such as fixed laying cables and flexible wires. The document serves as a technical reference for Zhengzhou Zoom Link Cable Co., Ltd.'s product offerings in electrical wiring solutions.

Uploaded by

48711905
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 28

ZML Cable link you & me

2020 EDITION
Contents
1. IEC60227 GB5023.3 JB8734 PVC Insulated Fix Laying Cable Unsheathed Cable……...…1

2. IEC60227 GB5023 JB8734 PVC Insulated Flexible Wire…………………………………...4

3. TW(60℃ Wet or Dry,600V)…………………………………………………………...10

4. THW(75℃ Wet or Dry,600V)………………….……………………………………...11

5. THWN(75℃ Wet or Dry,600V)…………………………..…………………………...12

6. THHN(90℃,600V)……………………………………..............……………………...13

7. TSJ / TSJ-N………………………………………………………..................................…...14

8. PVC-insulated wire H05V-U/K………………………………………...…………………...17

9. PVC-insulated wire H07V-U/R/K…………………………………………...……………...18

10. PVC-insulated cord H03VV-F………………………………………………..…………...19

11. PVC-insulated cord H05VV-F………………………………………………..…………...20


12. Solar Cabled..................................................................................................................21
Electirc Wire
1. IEC60227 GB5023.3 JB8734 PVC Insulated Fix Laying Cable Unsheathed Cable
PVC insulated fix laying cable unsheathed cable which rated voltage is 450/750V
or less (IEC60227,GB5023.3,JB8734) or fix laying cable is used at driving, home
appliance, apparatus and instruments which rated AC voltage is under 450/750V.

Specification:
1. The rated voltage of the cable and wires should equal to or higher than the rated
voltage of the system when the cable and wires are used at AC system. If the cable
and wires are used at DC system, the rated voltage of system should lower than 1.5
time as high as rated voltage of cable and wires. The working voltage of the system
could be 1.1 times as high as the rated voltage of the cable.
2. The long term working temperature should lower than 70℃. The working
temperature of BV-90 should lower than 90℃. And the laying temperature should
higher than 0℃.
3. The curve diameter of the cable and wire should longer than 8 times of the
diameter of the outer diameter of cable and wires if their outer diameter is 25 mm or
above. If the diameter of cable and wires is above 25 mm, the curve diameter should
be at least 12 times of the outer diameter of the cable and wires.

The detail and technical data of the products:


Type Name
60227IEC01(BV)
Hard conductor single thread cable without jacket
ZR-60227IEC01(BV)

BLV Aluminum conductor PVC insulated cable

BVR
Copper conductor PVC insulated flexible cable
ZR-BVR
60227IEC05(BV) Indoor purpose single thread without sheath which
conductor temperature is about 70℃
ZR-60227IEC05(BV)
Indoor purpose single thread without sheath which
60227IEC07(BV-90)
conductor temperature is about 90℃

Zhengzhou Zoom Link Cable Co.,ltd. - 1 -


60227IEC01(BV) Hard conductor single thread cable without jacket
ZR-60227IEC01(BV) Bursting stopping type hard conductor single thread cable without jacket
BLV Aluminum conductor PVC insulated cable
Number of the Max The resistance of the The resistance Weight
Section Thickness
thread/single diameter conductor at 20℃ of the insulator (reference)
area of the of the
conductor
thread
insulator
of the Ω/km ≤ at 70℃ kg/km
diameter cable
mm² mm Cu Al MΩ.km ≥ Cu Al
mm mm
1.5 1/1.38 0.7 3.3 12.1 -- 0.011 19.2 --
1.5 7/0.52 0.7 3.5 12.1 -- 0.010 20.6 --
2.5 1/1.78 0.8 3.9 7.41 11.8 0.010 30.8 15.0
4 1/2.25 0.8 4.4 4.61 7.39 0.0085 45.5 21.0
6 1/2.67 0.8 4.9 3.08 4.91 0.0070 65.5 29.0
10 7/1.35 1.0 7.0 1.83 3.08 0.0065 110.0 52.0
16 7/1.70 1.0 8.0 1.15 1.91 0.0050 170.0 70.0
25 7/2.14 1.2 10.0 0.727 1.20 0.0050 270.0 110.0
35 7/2.52 1.2 11.5 0.524 0.868 0.0040 364.0 150.0
50 19/1.78 1.4 13.0 0.387 0.641 0.0045 500.0 200.0
70 19/2.14 1.4 15.0 0.268 0.443 0.0035 688.0 269.0
95 19/2.52 1.6 17.5 0.193 0.320 0.0035 953.0 360.0
120 37/2.03 1.6 19.0 0.153 0.253 0.0032 1168.0 449.0
150 37/2.52 1.8 21.0 0.124 0.206 0.0032 1466.0 551.0
185 37/2.52 2.0 32.5 0.099 0.164 0.0032 1808.0 668.0

BVR 450/750V Copper conductor PVC insulated flexible cable


ZR-BVR 450/750V Bursting stopping type copper conductor PVC insulated flexible
cable
Number of The
Max The
Section the Thickness resistance of
diameter resistance of Weight
area of the thread/single of the the
of the the insulator (reference)
conductor thread insulator conductor at
cable at 70℃ kg/km
mm² diameter mm 20℃
mm MΩ.km ≥
mm Ω/km ≤
2.5 19/0.41 0.8 4.2 7.41 0.011 33.0
4 19/0.52 0.8 4.8 4.61 0.009 48.0
6 19/0.64 0.8 5.6 3.08 0.0084 68.0
10 49/0.52 1.0 7.6 1.83 0.0072 115.0
16 49/0.64 1.0 8.8 1.15 0.0062 176.0
25 98/0.58 1.2 11.0 0.727 0.0058 272.0
35 133/0.58 1.2 12.5 0.524 0.0052 384.0
50 133/0.68 1.4 14.5 0.387 0.0051 510.0
70 189/0.68 1.4 16.5 0.268 0.0045 714.0
95 259/0.68 1.6 19.5 0.139 0.0035 965.0
120 259/0.76 1.6 22.0 0.153 0.0032 1210.0
150 259/0.85 1.8 25.0 0.124 0.0032 1510.0

-2- Zhengzhou Zoom Link Cable Co.,ltd.


60227IEC05 (BV) Indoor purpose single thread without sheath which conductor
temperature is about 70℃

ZR-60227IEC05 (BV) Bursting stopping type indoor purpose single thread without
sheath which conductor temperature is about 70℃

Number of The The


Section Max
the Thickness resistance resistance
area of diameter Weight
thread/single of the of the of the
the of the (reference)
thread insulator conductor insulator at
conductor cable kg/km
diameter mm at 20℃ 70℃
mm² mm
mm Ω/km ≤ MΩ.km≥

0.5 1/0.80 0.6 2.4 36.0 0.015 8.1

0.75 1/0.97 0.6 2.6 24.5 0.012 10.6

1 1/1.13 0.6 2.8 18.1 0.011 13.2

60227IEC07(BV-90)Indoor purpose single thread without sheath which conductor


temperature is about 90℃

The The
Number of
Section Max resistance resistanc
the Thicknes Weight
area of diamete of the e of the
thread/singl s of the (reference
the r of the conductor insulator
e thread insulator )
conducto cable at 20℃ at 90℃
diameter mm kg/km
r mm² mm Ω/km MΩ.km
mm
≤ ≥

0.5 1/0.80 0.7 2.4 36.0 0.015 8.1

0.75 1/0.97 0.7 2.6 24.5 0.013 10.6

1 1/1.13 0.7 2.8 18.1 0.012 14.0

1.5 1/1.38 0.7 3.3 12.1 0.011 19.0

2.5 1.1.78 0.8 3.9 7.41 0.009 30.5

Zhengzhou Zoom Link Cable Co.,ltd. - 3 -


2. IEC60227 GB5023 JB8734 PVC Insulated Flexible Wire

PVC insulated flexible cable which rated voltage is 450/750V or under.


(IEC60227,GB5023.3,GB5023.5,JB8734.3) PVC insulated flexible wire can be
used at home appliance, mini type driving tools, instruments and apparatus and
lighting.

Specification:
The long term working temperature of electric wire should be less than 70 degree.
And the long term working temperature of RV-90 electric wire should be less than 90
degree.
Type Name
Indoor purpose single thread flexible conductor cable
60227IEC06(RV)
without sheath which conductor temperature is 70 degree
60227IEC02(RV) Common purpose single thread flexible conductor cable
ZR-60227IEC02(RV) without sheath.
Connecting purpose Copper conductor PVC Insulated
RVS
twisting flexible wire
60227IEC53(RVV) Common PVC sheathed flexible wire
60227IEC52(RVV) Light PVC sheathed flexible wire
Indoor purpose single thread flexible conductor
60227IEC08(RV-90)
non-sheathed wire which temperature is 90 degree
Light PVC sheathed flexible wire which conductor
60227IEC56(RVV-90)
temperature is 90 degree
Common PVC sheathed flexible wire which conductor
60227IEC57(RVV-90)
temperature is 90 degree

60227IEC06 (RV) 300/500V Indoor purpose single thread flexible conductor cable
without sheath which conductor temperature is 70℃

Number of The
Section Max The
the Thickness resistance
area of diameter resistance of Weight
thread/single of the of the
the of the the insulator (reference)
thread insulator conductor
conductor cable at 70℃ kg/km
diameter mm at 20℃
mm² mm MΩ.km ≥
mm Ω/km ≤
0.5 16/0.20 0.6 2.6 39.0 0.013 8.5
0.75 24/0.20 0.6 2.8 26.0 0.011 13
1 32/0.20 0.6 3.0 19.5 0.010 16

- 4 - Zhengzhou Zoom Link Cable Co.,ltd.


60277IEC02(RV)450/750V Common purpose single thread flexible conductor cable
without sheath

ZR-60227 IEC02(RV)450/750V Bursting stopping type common purpose single


thread flexible conductor cable without sheath

Section Max The resistance


Number of the Thickness The resistance
area of diameter of the Weight
thread/single of the of the insulator
the of the conductor at (reference)
thread diameter insulator at 70℃
conductor cable 20℃ kg/km
mm mm MΩ.km ≥
mm² mm Ω/km ≤

1.5 30/0.25 0.7 3.5 13.3 0.00.01010 20.0

2.5 49/0.25 0.8 4.2 7.98 0.009 31.0

4 56/0.30 0.8 4.8 4.95 0.007 47.0

6 84/0.30 0.8 6.3 2.30 0.006 66.0

10 84/0.40 1.0 7.6 1.91 0.0056 119.0

16 126/0.40 1.0 8.8 1.21 0.0046 176

25 196/0.40 1.2 11.0 0.78 0.0044 280

35 270/0.40 1.2 12.5 0.554 0.0038 379

50 396/0.40 1.4 14.5 0.386 0.0037 510

70 360/0.50 1.4 17.0 0.272 0.0032 729

Zhengzhou Zoom Link Cable Co.,ltd. -5-


60227IEC53(RVV)300/500V Common PVC sheathed flexible wire

Average radius or The The


Number of Number of the
Thickness Thickness overall dimension resistance resistance
the thread thread/single
of the of the mm of the of the
×Section thread
insulator jacket conductor insulator at
area diameter
mm mm Minimum Maximum at 20℃ 70℃
mm2 mm
Ω/km ≤ MΩ.km≥
5.7 7.2
2×0.75 24/0.2 0.6 0.8 26.0 0.011
3.7×6.0 4.5×7.2

3×0.75 24/0.2 0.6 0.8 6.0 7.6 26.0 0.011

4×0.75 24/0.2 0.6 0.8 6.6 8.3 26.0 0.011

5×0.75 24/0.2 0.6 0.9 7.4 9.3 26.0 0.011

5.9 7.5
2×1 32/0.2 0.6 0.8 19.5 0.010
3.9×6.2 4.7×7.5

3×1 32/0.2 0.6 0.8 6.3 8.0 19.5 0.010

4×1 32/0.2 0.6 0.9 7.1 9.0 19.5 0.010

5×1 32/0.2 0.6 0.9 7.8 9.8 19.5 0.010

2×1.5 30/0.25 0.7 0.8 6.8 8.6 13.3 0.010

3×1.5 30/0.25 0.7 0.8 7.4 9.4 13.3 0.010

4×1.5 30/0.25 0.7 1.0 8.4 10.5 13.3 0.010

5×1.5 30/0.25 0.7 1.1 9.3 11.6 13.3 0.010

2×2.5 49/0.25 0.8 1.0 8.4 10.6 7.98 0.009

3×2.5 49/0.25 0.8 1.1 9.2 11.4 7.98 0.009

4×2.5 49/0.25 0.8 1.2 10.1 12.5 7.98 0.009

5×2.5 49/0.25 0.8 1.2 11.2 13.9 7.98 0.009

- 6 - Zhengzhou Zoom Link Cable Co.,ltd.


60227IEC52(RVV) 300/300V Light PVC sheathed flexible wire

The
Number of The
Number of Average radius or resistance
the Thickness Thickness resistance
the thread overall dimension of the
thread/single of the of the of the
×Section mm insulator
thread insulator jacket conductor
area at 70℃
diameter mm mm at 20℃
mm2 MΩ.km
mm Minimum Maximum Ω/km ≤

2×0.5 16/0.2 0.5 0.6 4.6 5.9


39.0 0.012
2×0.5 16/0.2 0.5 0.6 3.0×4.9 3.7×5.9

2×0.75 34/0.2 0.5 0.6 4.9 6.3


26.0 0.010
2×0.75 24/0.2 0.5 0.6 3.2×5.2 3.8×6.3

3×0.5 16/0.2 0.5 0.6 4.9 6.3 39.0 0.012

3×0.75 24/0.2 0.5 0.6 5.2 6.7 26.0 0.010

60227IEC08(RV-90) 300/500V Indoor purpose single thread flexible conductor


non-sheathed wire which temperature is 90℃

The resistance
Section Number of the Thickness The resistance
Max diameter of the
area of the thread/single of the of the insulator
of the cable conductor at
conductor thread diameter insulator at 90℃
mm 20℃
mm² mm mm MΩ.km ≥
Ω/km ≤

0.5 16/0.2 0.6 2.6 39.0 0.013

0.75 24/0.2 0.6 2.8 26.0 0.012

1.0 32/0.2 0.6 3.0 19.5 0.010

1.5 30/0.25 0.7 3.5 13.3 0.009

2.5 49/0.25 0.8 4.2 7.98 0.009

Zhengzhou Zoom Link Cable Co.,ltd. - 7 -


60227IEC56(RVV-90) 300/300V Light PVC sheathed flexible wire which conductor
temperature is 90 degree

The
Number of The
Number of Average radius or resistance
the Thickness Thickness resistance
the thread overall dimension of the
thread/single of the of the of the
×Section mm insulator
thread insulator jacket conductor
area at 90℃
diameter mm mm at 20℃
mm2 MΩ.km
mm Minimum Maximum Ω/km ≤

2×0.5 16/0.2 0.5 0.6 4.6 5.9


39.0 0.012
2×0.5 16/0.2 0.5 0.6 3.0×4.9 3.7×5.9

2×0.75 34/0.2 0.5 0.6 4.9 6.3


26.0 0.010
2×0.75 24/0.2 0.5 0.6 3.2×5.2 3.8×6.3

3×0.5 16/0.2 0.5 0.6 4.9 6.3 39.0 0.012

3×0.75 24/0.2 0.5 0.6 5.2 6.7 26.0 0.010

- 8 - Zhengzhou Zoom Link Cable Co.,ltd.


60227IEC57(RVV-90) 300/500V Common PVC sheathed flexible wire which
conductor temperature is 90 degree

Average radius or The The


Number of Number of the
Thickness Thickness overall dimension resistance resistance
the thread thread/single
of the of the mm of the of the
×Section thread
insulator jacket conductor insulator at
area diameter
mm mm Minimum Maximum at 20℃ 90℃
mm2 mm
Ω/km ≤ MΩ.km≥
5.7 7.2
2×0.75 24/0.2 0.6 0.8 26.0 0.011
3.7×6.0 4.5×7.2

3×0.75 24/0.2 0.6 0.8 6.0 7.6 26.0 0.011

4×0.75 24/0.2 0.6 0.8 6.6 8.3 26.0 0.011

5×0.75 24/0.2 0.6 0.9 7.4 9.3 26.0 0.011

5.9 7.5
2×1 32/0.2 0.6 0.8 19.5 0.010
3.9×6.2 4.7×7.5
3×1 32/0.2 0.6 0.8 6.3 8.0 19.5 0.010

4×1 32/0.2 0.6 0.9 7.1 9.0 19.5 0.010

5×1 32/0.2 0.6 0.9 7.8 9.8 19.5 0.010

2×1.5 30/0.25 0.7 0.8 6.8 8.6 13.3 0.010

3×1.5 30/0.25 0.7 0.8 7.4 9.4 13.3 0.010

4×1.5 30/0.25 0.7 1.0 8.4 10.5 13.3 0.010

5×1.5 30/0.25 0.7 1.1 9.3 11.6 13.3 0.010

2×2.5 49/0.25 0.8 1.0 8.4 10.6 7.98 0.009

3×2.5 49/0.25 0.8 1.1 9.2 11.4 7.98 0.009

4×2.5 49/0.25 0.8 1.2 10.1 12.5 7.98 0.009

5×2.5 49/0.25 0.8 1.2 11.2 13.9 7.98 0.009

Zhengzhou Zoom Link Cable Co.,ltd. - 9 -


3. TW(60℃ Wet or Dry,600V)
 Standard: UL83

● Use
Building wire. 60℃ oil resistant.
Suitable for use in wet or dry locations.

● Construction
PVC insulated.

TW
Conductor Insulation
Part
Nominal Nominal Maximum Ref.W.
Size Construction Diameter
No. Type Thickness Diameter Diameter
(AWG) (No./mm) (mm) (kg/km)
(mm) (mm) (mm)
TW-14B 14 7/0.62 1.86 0.76 3.42 3.8 29.1
TW-12B 12 7/0.78 2.34 0.76 3.90 4.4 42.2
TW-10B 10 7/0.98 2.94 0.76 4.50 5.0 62.3
TW-8B 8 7/1.23 3.69 1.14 6.01 6.7 103.1
TW-6B 6 7/1.56 4.68 1.52 7.76 8.7 169.2
TW-4B 4 7/1.96 5.88 1.52 8.96 10.0 249.5
Stranded
TW-3B 3 7/2.20 6.60 1.52 9.68 10.8 306.2
conductor
TW-2B 2 7/2.47 7.41 1.52 10.49 11.7 376.4
TW-1B 1 19/1.68 8.40 2.03 12.50 14.0 487.8
TW-1/0B 1/0 19/1.89 9.45 2.03 13.55 15.1 600.7
TW-2/0B 2/0 19/2.12 10.60 2.03 14.70 16.4 739.2
TW-3/0B 3/0 19/2.38 11.90 2.03 16.00 17.8 912.4
TW-4/0B 4/0 19/2.67 13.35 2.03 17.45 19.4 1130.2
TW-14A 14 1/1.63 1.63 0.76 3.19 3.6 27.5
TW-12A Solid 12 1/2.05 2.05 0.76 3.61 4.0 39.9
TW-10A conductor 10 1/2.59 2.59 0.76 4.15 4.6 59.1
TW-8A 8 1/3.26 3.26 1.14 5.58 6.3 98.5

● 表面印字标记: ● Surface marking


TW XXAWG OIL RESISTANT Ⅰ 600V VW-1

- 10 - Zhengzhou Zoom Link Cable Co.,ltd.


4. THW(75℃ Wet or Dry,600V)

 Standard: UL83

● Use
Building wire. 75℃ oil resistant.
Suitable for use in wet or dry locations.

● Construction
PVC insulated.

THW
Conductor Insulation
Part Ref.W.
Nominal Nominal Maximum
Size Construction Diameter
No. Type Thickness Diameter Diameter (kg/km)
(AWG) (No./mm) (mm)
(mm) (mm) (mm)
THW-14B 14 7/0.62 1.86 0.76 3.42 3.8 29.1
THW-12B 12 7/0.78 2.34 0.76 3.90 4.4 42.2
THW-10B 10 7/0.98 2.94 0.76 4.50 5.0 62.3
THW-8B 8 7/1.23 3.69 1.14 6.01 6.7 103.1
THW-6B 6 7/1.56 4.68 1.52 7.76 8.7 169.2
Stranded
THW-4B 4 7/1.96 5.88 1.52 8.96 10.0 249.5
conductor
THW-3B 3 7/2.20 6.60 1.52 9.68 10.8 306.2

THW-2B 2 7/2.47 7.41 1.52 10.49 11.7 376.4

THW-1B 1 19/1.68 8.40 2.03 12.50 14.0 487.8
THW-1/0B 1/0 19/1.89 9.45 2.03 13.55 15.1 600.7
THW-2/0B 2/0 19/2.12 10.60 2.03 14.70 16.4 739.2
THW-3/0B 3/0 19/2.38 11.90 2.03 16.00 17.8 912.4
THW-4/0B 4/0 19/2.67 13.35 2.03 17.45 19.4 1130.2
THW-14A 14 1/1.63 1.63 0.76 3.19 3.6 27.5
THW-12A Solid 12 1/2.05 2.05 0.76 3.61 4.0 39.9
THW-10A conductor 10 1/2.59 2.59 0.76 4.15 4.6 59.1
THW-8A 8 1/3.26 3.26 1.14 5.58 6.3 98.5

● Surface marking
THW XXAWG OIL RESISTANT Ⅰ 600V

Zhengzhou Zoom Link Cable Co.,ltd. - 11 -


5. THWN(75℃ Wet or Dry,600V)

 Standard: UL83

● Use
Building wire. 75℃ oil resistant, gasoline resistant.
Suitable for use in wet or dry locations.

● Construction
PVC insulated.
Nylon sheathed.

THWN
Conductor Insulation Jacket
Max
Minimum Ref.W
Dia-
PartNo. Dia- Nominal Nominal Thickness Nominal 
Size Construction meter
Type Meter Thickness Diameter Atany Diameter (kg/km)
(AWG) (No./mm) (mm)
(mm) (mm) (mm) point (mm)
(mm)
THWN-14B 14 7/0.62 1.86 0.38 2.66 0.10 2.90 3.3 25.2
THWN-14B1 14 19/0.38 1.90 0.38 2.70 0.10 2.94 3.4 25.4
THWN-12B 12 7/0.78 2.34 0.38 3.14 0.10 3.38 3.8 38.2
THWN-12B1 12 19/0.47 2.35 0.38 3.15 0.10 3.39 3.8 38.6
THWN-10B 10 7/0.98 2.94 0.51 4.00 0.10 4.24 4.8 59.1
THWN-10B1 10 19/0.60 3.00 0.51 4.06 0.10 4.30 4.8 59.6
THWN-8B 8 7/1.23 3.69 0.76 5.25 0.13 5.55 6.2 97.1
THWN-8B1 8 19/0.75 3.75 0.76 5.31 0.13 5.61 6.3 96.7
THWN-6B 6 7/1.56 4.68 0.76 6.24 0.13 6.54 7.3 147.0
THWN-6B1 6 19/0.95 4.77 0.76 6.33 0.13 6.63 7.4 146.5
Stranded
THWN-4B 4 7/1.96 5.88 0.76 7.44 0.13 7.74 8.7 135.8
conductor
THWN-4B1 4 19/1.19 5.95 0.76 7.51 0.13 7.81 8.7 135.7
THWN-3B 3 7/2.20 6.60 1.02 8.68 0.15 9.02 10.0 292.2
THWN-3B1 3 19/1.33 6.65 1.02 8.73 0.15 9.07 10.0 291.6
THWN-2B 2 7/2.47 7.41 1.02 9.49 0.15 9.83 11.0 361.5
THWN-2B1 2 19/1.50 7.50 1.02 9.58 0.15 9.92 11.0 361.0
THWN-1B 1 19/1.68 8.40 1.02 10.48 0.18 10.88 12.1 457.8
THWN-1/0B 1/0 19/1.89 9.45 1.27 12.03 0.18 12.43 13.8 585.6
THWN-2/0B 2/0 19/2.12 10.60 1.27 13.18 0.18 13.58 15.1 724.7
THWN-3/0B 3/0 19/2.38 11.90 1.27 14.48 0.18 14.88 16.5 900.2
THWN-4/0B 4/0 19/2.67 13.35 1.27 15.93 0.18 16.33 18.1 1118.2
THWN-14A 14 1/1.63 1.63 0.38 2.43 0.10 2.67 3.1 22.6
THWN-12A Solid 12 1/2.05 2.05 0.38 2.85 0.10 3.09 3.5 36.1
THWN-10A conductor 10 1/2.59 2.59 0.51 3.65 0.10 3.89 4.4 57.4
THWN-8A 8 1/3.26 3.26 0.76 4.82 0.13 5.12 5.7 94.7

● Surface marking
THWN XXAWG GASOLINE AND OIL RESISTANT Ⅱ 600V

- 12 - Zhengzhou Zoom Link Cable Co.,ltd.


6. THHN(90℃,600V)

 Standard: UL83

● Use
Building wire. 90℃ oil resistant.
Suitable for use in dry locations.
● Construction
PVC insulated.
Nylon sheathed.
THHN
Conductor Insulation Jacket
Minimum Max
Ref.W
Size Dia- Nominal Nominal Thickness Nominal Dia-
PartNo. Construction meter

Type (AWG Meter Thickness Diameter Atany Diameter (kg/km)
(No./mm) (mm)
) (mm) (mm) (mm) point (mm)
(mm)
THHN-14B 14 7/0.62 1.86 0.38 2.66 0.10 2.90 3.3 25.2
THHN-14B1 14 19/0.38 1.90 0.38 2.70 0.10 2.94 3.4 25.4
THHN-12B 12 7/0.78 2.34 0.38 3.14 0.10 3.38 3.8 38.2
THHN-12B1 12 19/0.47 2.35 0.38 3.15 0.10 3.39 3.8 38.6
THHN-10B 10 7/0.98 2.94 0.51 4.00 0.10 4.24 4.8 59.1
THHN-10B1 10 19/0.60 3.00 0.51 4.06 0.10 4.30 4.8 59.6
THHN-8B 8 7/1.23 3.69 0.76 5.25 0.13 5.55 6.2 97.1
THHN-8B1 8 19/0.75 3.75 0.76 5.31 0.13 5.61 6.3 96.7
THHN-6B 6 7/1.56 4.68 0.76 6.24 0.13 6.54 7.3 147.0
THHN-6B1 6 19/0.95 4.77 0.76 6.33 0.13 6.63 7.4 146.5
Stranded
THHN-4B 4 7/1.96 5.88 0.76 7.44 0.13 7.74 8.7 135.8
conductor
THHN-4B1 4 19/1.19 5.95 0.76 7.51 0.13 7.81 8.7 135.7
THHN-3B 3 7/2.20 6.60 1.02 8.68 0.15 9.02 10.0 292.2
THHN-3B1 3 19/1.33 6.65 1.02 8.73 0.15 9.07 10.0 291.6
THHN-2B 2 7/2.47 7.41 1.02 9.49 0.15 9.83 11.0 361.5
THHN-2B1 2 19/1.50 7.50 1.02 9.58 0.15 9.92 11.0 361.0
THHN-1B 1 19/1.68 8.40 1.02 10.48 0.18 10.88 12.1 457.8
THHN-1/0B 1/0 19/1.89 9.45 1.27 12.03 0.18 12.43 13.8 585.6
THHN-2/0B 2/0 19/2.12 10.60 1.27 13.18 0.18 13.58 15.1 724.7
THHN-3/0B 3/0 19/2.38 11.90 1.27 14.48 0.18 14.88 16.5 900.2
THHN-4/0B 4/0 19/2.67 13.35 1.27 15.93 0.18 16.33 18.1 1118.2
THHN-14A 14 1/1.63 1.63 0.38 2.43 0.10 2.67 3.1 22.6
THHN-12A Solid 12 1/2.05 2.05 0.38 2.85 0.10 3.09 3.5 36.1
THHN-10A conductor 10 1/2.59 2.59 0.51 3.65 0.10 3.89 4.4 57.4
THHN-8A 8 1/3.26 3.26 0.76 4.82 0.13 5.12 5.7 94.7

● Surface marking
THHN XXAWG OIL RESISTANT Ⅱ 600V

Zhengzhou Zoom Link Cable Co.,ltd. - 13 -


7. TSJ / TSJ-N

600 V Flexible Thermoplastic Insulated Multiconductor. Each single conductor has a


Thermoplastic Insulation protected with a Nylon Sheath, then the whole
Multiconductor is protected by a Thermoplastic Jacket

PVC Insulation, Nylon cover

Flexible Copper Conductor Application


PVC Jacket This product has been designed to
1 operate at no more than 60ºC in dry or
wet conditions. Besides that, the Nylon
Detail Description sheath provides protection to chemical
agents and petroleum derivatives,
or Construction therefore this product might be used for
TSJ conductor is an insulated wiring solutions at either industrial or
multiconductor composed by commercial and residential applications.
bunch-stranded annealed copper Its black pigmentation on the external
flexible conductors, each single cord has jacket resist the ultraviolet sun light
a thermoplastic insulation of PVC exposure, thereby, these might be used
(Polyvinyl Chloride) and its protected by at outside or wet applications.
a Nylon sheath, in addition, the whole
multiconductor is protected by a Standards / Testing
thermoplastic insulation of PVC.
Designed to operate at not more than Specifications
600V, the TSJ is manufactured in • TSJ conductors have been designed
constructions duplex (two single according to ASTM B172, B174, UL-62
conductors), triplex (three single and UL-83 specifications and
conductors) and quadruplex (four single requirements of the latest version of the
conductors), also in sizes from 20 AWG National Electrical Code (NEC).
up to 6AWG. Product color identification
is the following: Marking
Duplex: black- white SANHE TSJ # X (GAUGE) AWG
Triplex: black-white-red (GAUGE) mm ² ) 600V WATER
Quadruplex: black-white-red-green RESISTANT.

- 14 - Zhengzhou Zoom Link Cable Co.,ltd.


Construction Cross External Approximate
Number of
Section Area Cover Thickness Total Diameter
Strands
AWG / MCM mm² in mm in mm

2x20 0.52 7 0.030 0.76 0.225 5.72

2x18 0.82 10 0.030 0.76 0.250 6.35

2x16 1.31 16 0.030 0.76 0.275 6.99

2x14 2.08 26 0.030 0.76 0.315 8.00

2x12 3.31 41 0.045 1.14 0.380 9.65

2x10 5.26 65 0.060 1.52 0.480 12.19

2x8 8.37 105 0.060 1.52 0.590 14.99

2x6 13.30 168 0.060 1.52 0.690 17.53

3x18 0.82 10 0.030 0.76 0.265 6.73

3x16 1.31 16 0.030 0.76 0.290 7.37

3x14 2.08 26 0.030 0.76 0.330 8.38

3x12 3.31 41 0.045 1.14 0.400 10.16

3x10 5.26 65 0.060 1.52 0.500 12.70

3x8 8.37 105 0.060 1.52 0.630 16.00

3x6 13.30 168 0.060 1.52 0.700 17.78

4x18 0.82 10 0.030 0.76 0.285 7.24

4x16 1.31 16 0.030 0.76 0.320 8.13

4x14 2.08 26 0.030 0.76 0.360 9.14

4x12 3.31 41 0.045 1.14 0.440 11.18

4x10 5.26 65 0.060 1.52 0.540 13.72

4x8 8.37 105 0.060 1.52 0.680 17.27

4x6 13.30 168 0.060 1.52 0.775 19.69

Zhengzhou Zoom Link Cable Co.,ltd. - 15 -


Max.D.C.
Aproximate Max. Current
Minimum Electrical Standard
Construction Total Capacity
Curvature Resistance Packaging
Weight at 30°C
at 30°C

AWG / MCM Kg / Km mm Ω / Km A B m

2x20 38 86 36.2 --- 7 C 100. WR 500. WR 1000

2x18 48 95 22.9 --- 10 C 100. WR 500. WR 1000

2x16 63 105 14.4 --- 13 C 100. WR 500. WR 1000

2x14 86 120 9.07 --- 18 C 100. WR 500. WR 1000

2x12 134 145 5.74 --- 25 C 100. WR 500. WR 1000

2x10 217 183 3.59 --- 30 C 100. WR 500. WR 1000

2x8 336 225 2.25 --- 40 C 100. WR 500. WR 1000

2x6 475 263 1.42 --- 55 C 100. WR 500. WR 1000

3x18 58 101 22.9 7 10 C 100. WR 500. WR 1000

3x16 78 110 14.4 10 13 C 100. WR 500. WR 1000

3x14 108 126 9.07 15 18 C 100. WR 500. WR 1000

3x12 168 152 5.74 20 25 C 100. WR 500. WR 1000

3x10 272 191 3.59 25 30 C 100. WR 500. WR 1000

3x8 424 240 2.25 35 40 C 100. WR 500. WR 1000

3x6 609 267 1.42 45 55 C 100. WR 500. WR 1000

4x18 70 109 22.9 7 --- C 100. WR 500. WR 1000

4x16 96 122 14.4 10 --- C 100. WR 500. WR 1000

4x14 134 137 9.07 15 --- C 100. WR 500. WR 1000

4x12 209 168 5.74 20 --- C 100. WR 500. WR 1000

4x10 337 206 3.59 25 --- C 100. WR 500. WR 1000

4x8 528 259 2.25 35 --- C 100. WR 500. WR 1000

4x6 765 295 1.42 45 --- C 100. WR 500. WR 1000

Packaging: WR-Wooden Reel, C-Coils

- 16 - Zhengzhou Zoom Link Cable Co.,ltd.


8. PVC-insulated wire H05V-U/K
Nominal Voltage: 300/500 V
Conductor: bare copper, solid (V-U) or
fine stranded (V-K)
Insulation: PVC
Test voltage: 2000 V
Flame retardance: IEC 332-1
max. operating temperature: 70 °C
min. operating temperature: -40 °C
Application: For internal wiring of switching boxes and other electrical
appliances, for installation in closed conduits and tubes. Not for direct
installation under plaster.

Dl Rl De Wi Ri Rbv Rbf DA G Cu Ik Ibl FZ


max. max. max. nom. min. min. min. min. max. nom. nom. nom. max.
[mm] [Ω/km [mm] [mm] [MΩ.km] [mm] [mm] [mm] [mm] [kg/km] [kg/km] [kA] [A] [N]
V-U

1 x 0.5 0.9 36.0 - 0.60 0.015 9 3 1.9 2.3 9.0 4.8 0.057 6 25

1 x 0.75 1.0 24.5 - 0.60 0.012 10 3 2.0 2.2 10.0 7.2 0.086 15 38

1 x 1.0 1.2 18.1 - 0.60 0.011 11 3 2.2 2.8 14.0 9.6 0.115 19 50

V-K

1 x 0.5 1.1 39.0 0.21 0.60 0.013 9 3 2.1 2.5 10.0 4.8 0.057 6 25

1 x 0.75 1.3 26.0 0.21 0.60 0.011 11 3 2.2 2.7 12.0 7.2 0.086 15 11

1 x 1.0 1.5 19.5 0.21 0.60 0.010 12 3 2.4 2.8 14.0 9.6 0.115 19 15

Dl - diameter of the conductor


Rl - conductor resistance at 20 °C
De - diameter of a single wire within a stranded conductor
Wi - thickness of insulation
Ri - insulation resistance at 70 °C
Rb - bending radius (Rbv - fixed application,
Rbf - during installation,
Rbb - flexible application)
DA - outer diameter of the cable
G - specific weight
Cu - specific contents of Cu
Ik - rated short circuit current (1 s)
Ibl - rated current (in air)
Fz - max. permitted pulling force

Zhengzhou Zoom Link Cable Co.,ltd. - 17 -


9. PVC-insulated wire H07V-U/R/K
Nominal Voltage: 450/750 V
Conductor: bare copper, solid (V-U); stranded (V-R),
fine stranded (V-K)
Insulation: PVC
Test voltage: 2500 V
Flame retardance: IEC 332-1
max. operating temperature: 70 °C
min. operating temperature: -40 °C
Application: For wiring inside of switching boxes and other electrical appliances, for
installation in closed conduits and tubes. Not for direct installation under plaster.
Types/dimensions
Dl Rl De Wi R i Rbv Rbf DA G Cu Ik Ibl
max. max. max. nom. min. min. min. min. max. nom. nom. nom.
[mm] [Ω/km [mm] [mm] [MΩ.km] [mm] [mm] [mm] [mm] [kg/km] [kg/km] [kA] [A]
V-U
1x 1.5 1.50 12.10 - 0.7 0.011 13 3 2.6 3.3 20 14.4 0.172 24
1x 2.5 1.90 7.41 - 0.8 0.010 16 4 3.2 3.9 31 24.0 0.287 32
1x 4 2.40 4.61 - 0.8 0.0085 18 4 3.6 4.4 46 38.0 0.460 42
1x 6 2.90 3.08 - 0.8 0.0070 20 5 4.1 4.9 65 58.0 0.690 54
1x 10 3.70 1.83 - 1.0 0.0070 26 6 5.3 6.4 110 96.0 1.15 73
V-R
1x 16 5.3 1.150 1.70 1.0 0.0050 32 8 6.6 8.0 175 154.0 1.84 98
1x 25 6.6 0.727 2.13 1.2 0.0050 39 10 8.3 9.8 275 240.0 2.88 129
1x 35 7.9 0.524 2.52 1.2 0.0040 44 22 9.3 11.0 370 336.0 4.02 158
1x 50 9.1 0.387 1.83 1.4 0.0045 52 26 10.9 13.0 500 480.0 5.75 198
1x 70 11.0 0.268 2.17 1.4 0.0035 60 30 12.5 15.0 710 672.0 8.05 245
1x 95 12.9 0.193 2.52 1.6 0.0035 68 34 14.6 17.0 970 912.0 10.9 292
1x 120 14.5 0.153 2.03 1.6 0.0032 76 38 16.1 19.0 1200 1152.0 13.8 344
1x 150 16.2 0.124 2.27 1.8 0.0032 84 42 17.9 21.0 1470 1440.0 17.3 391
V-K
1x 1.5 1.8 13.3 0.26 0.7 0.010 14 4 2.8 3.4 20 14.4 0.172 24
1x 2.5 2.6 7.98 0.26 0.8 0.009 17 4 3.4 4.1 32 24.0 0.287 32
1x 4 3.2 4.95 0.31 0.8 0.007 19 5 3.9 4.8 46 38.0 0.460 42
1x 6 3.9 3.30 0.31 0.8 0.006 25 6 4.4 5.3 65 58.0 0.690 54
1x 10 5.1 1.91 0.41 1.0 0.0056 30 8 5.7 6.8 115 96.0 1.15 73
1x 16 6.3 1.21 0.41 1.0 0.0046 35 9 6.7 8.1 170 154.0 1.84 98
1x 25 7.8 0.780 0.41 1.2 0.0044 44 22 8.3 11.0 260 240.0 2.88 129
1x 35 9.2 0.554 0.41 1.2 0.0038 50 25 9.7 11.7 360 336.0 4.02 158
1x 50 11.0 0.386 0.41 1.4 0.0037 58 29 11.5 13.9 515 480.0 5.75 198
1x 70 13.1 0.272 0.51 1.4 0.0032 68 34 13.2 16.0 710 672.0 8.05 245
1x 95 15.0 0.206 0.51 1.6 0.0032 76 38 15.1 18.2 940 912.0 10.9 292
1x 120 17.0 0.161 0.51 1.6 0.0029 84 42 16.7 20.2 1180 1152.0 13.8 344
1x 150 19.0 0.129 0.51 1.8 0.0029 94 47 18.6 22.5 1600 1440.0 17.3 391
1x 185 2.0 0.0029 103 51 20.6 24.9 2100 1776.0
1x 240 2.2 0.0028 117 59 23.5 28.4 3015 2304.0

- 18 - Zhengzhou Zoom Link Cable Co.,ltd.


10. PVC-insulated cord H03VV-F
Nominal voltage: 300/300 V
Conductor: Cu, bare, fine stranded class 5
Insulation: PVC
Sheath: PVC
Colors: black, white
Test voltage: 2000 V, 15 min.
max. operating temperature: 70 °C
min. operating temperature: -40 °C
max. installation temperature: 70 °C
min. installation temperature: 5 °C
Application: For connection of light household appliances (desktop lamps,
kitchen appliances, vacuum cleaner, office appliances, radios etc.) with low
mechanical stress in households, kitchens or offices. Not for connection of
cooking or heating devices or electrical tools and not for use outside of closed
places.
Types/dimensions:
Dl De Wi Ri DA G Cu Rl
max. max. nom. min. min. max. nom. max. nom.
[mm] [mm] [mm] [MΩ.km] [mm] [mm] [kg/km] [Ω/km [kA]
2x0.75 1.3 0.21 0.6 0.010 5.2 6.4 46 14.4 26.0
3G0.75 1.3 0.21 0.6 0.010 5.4 6.8 55 21.6 26.0
4G0.75 1.3 0.21 0.6 0.010 6.0 7.4 69 29.0 26.0

Zhengzhou Zoom Link Cable Co.,ltd. - 19 -


11. PVC-insulated cord H05VV-F
Nominal voltage: 300/500 V
Conductor: Cu, bare, fine stranded class 5
Insulation: PVC
Sheath: PVC
Colors: black, white
Test voltage: 2000 V, 15 min.
max. operating temperature: 70 °C
min. operating temperature: -40 °C
max. installation temperature: 70 °C
min. installation temperature: 5 °C
Application: For flexible connection of electrical appliances with medium
mechanical stress in households, kitchens, offices, also for household
appliances in wet rooms, if permitted by standards for appliances. Not for use
outside closed rooms.
Types/dimensions:
Dl De Wi Ri Rbv Rbb DA G Cu Rl Ik Ibl
max. max. nom. min. min. min. min. max. nom. max. nom. nom.
[mm] [mm] [mm] [MΩ.km] [mm] [mm] [mm] [mm] [kg/km [kg/km] [Ω/km [kA] [A]

2 X 0.75 1.3 0.21 0.6 0.011 16.8 33.6 5.7 7.2 52 14.4 31.1 0.082 6

2X1 1.5 0.21 0.6 0.010 19.2 38.4 6.4 8.0 65 19.0 23.3 0.109 10

2 X 1.5 1.8 0.26 0.6 0.010 22.2 44.4 7.4 9.0 90 29.0 15.9 0.163 16

2 X 2.5 2.6 0.26 0.8 0.009 26.7 53.4 8.9 11.0 115 48.0 9.5 0.272 25

3 G 0.75 1.3 0.21 0.6 0.011 19.2 38.4 6.4 8.0 70 21.6 31.1 0.082 6

3G1 1.8 0.26 0.6 0.010 20.4 40.8 6.8 8.4 80 29.0 23.3 0.109 10

3 G 1.5 1.8 0.26 0.6 0.010 24.0 48.0 8.0 9.8 115 48.0 15.9 0.163 16

3 G 2.5 2.6 0.26 0.8 0.009 28.8 57.6 9.6 12.0 175 72.0 9.5 0.272 25

4 G 0.75 1.3 0.21 0.6 0.011 19.8 39.6 6.6 8.3 75 29.0 31.1 0.082 6

4G1 1.5 0.26 0.6 0.010 21.3 42.6 7.1 9.0 92 38.0 23.3 0.109 10

4 G 1.5 1.8 0.26 0.6 0.010 27.0 54.0 9.0 11.0 145 58.0 15.9 0.163 16

4 G 2.5 2.6 0.26 0.8 0.009 31.5 63.0 10.5 13.0 210 96.0 9.5 0.272 25

5 G 0.75 1.3 0.21 0.6 0.011 22.2 44.4 7.4 9.3 96 36.0 31.1 0.082 6

5G1 1.5 0.26 0.6 0.010 23.4 46.8 7.8 9.8 113 48.0 23.3 0.109 10

5 G 1.5 1.8 0.26 0.6 0.010 30.0 60.0 10.0 12.0 175 72.0 15.9 0.163 16

5 G 2.5 2.6 0.26 0.8 0.009 34.5 69.0 11.5 14.0 260 120.0 9.5 0.272 25

- 20 - Zhengzhou Zoom Link Cable Co.,ltd.


Zhengzhou Zoom Link Cable Co.,ltd. - 21-
- 22 - Zhengzhou Zoom Link Cable Co.,ltd.
Zhengzhou Zoom Link Cable Co.,ltd. - 23 -
- 24 - Zhengzhou Zoom Link Cable Co.,ltd.

You might also like