SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
& ANSI/NCSL Z540-1-1994
ROTRONIC INSTRUMENT CORPORATION
135 Engineers Road, Suite 150
Hauppauge, NY 11788
Mr. Jim Vetrano Phone: 631 427 3898
CALIBRATION
Valid To: December 31, 2023 Certificate Number: 5622.01
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following calibrations 1, 5:
I. Thermodynamics
Parameter/Equipment Range CMC2, 3, 4, 6 (±) Comments
Relative Humidity –
Measuring Equipment
Nominal 23 °C (0.1 to 0.8) % RH 0.21 % RH Fixed humidity tunnels, chilled
(10.2 to 11.8) % RH 0.32 % RH mirror, transfer hygrometers,
(34 to 36) % RH 0.44 % RH and thermistor probe with
(79 to 81) % RH 0.79 % RH digital thermometer
Selected Point Service (4.5 to 5.5) % RH 0.12 % RH HygroGen humidity generator,
(5.5 to 10.5) % RH 0.15 % RH chilled mirror, thermistor probe
(10.5 to 15.5) % RH 0.17 % RH with digital thermometer
(15.5 to 26) % RH 0.33 % RH
(26 to 36) % RH 0.39 % RH
(36 to 64) % RH 0.45 % RH
(64 to 66) % RH 0.50 % RH
(66 to 81) % RH 0.55 % RH
(81 to 89) % RH 0.58 % RH
(89 to 94) % RH 0.65 % RH
(94 to 96) % RH 0.74 % RH
(A2LA Cert. No. 5622.01) 11/11/2021 Page 1 of 2
Parameter/Equipment Range CMC2, 3, 4, 6 (±) Comments
Relative Humidity –
Measuring Equipment
(cont)
Water Activity Meters (0.045 to 0.055) aw 0.0012 aw Humidity generator, chilled
(0.055 to 0.105) aw 0.0015 aw mirror, thermistor probe with
(0.105 to 0.155) aw 0.0017 aw digital thermometer
(0.155 to 0.26) aw 0.0033 aw
(0.26 to 0.36) aw 0.0039 aw
(0.36 to 0.64) aw 0.0045 aw
(0.64 to 0.66) aw 0.0050 aw
(0.66 to 0.81) aw 0.0055 aw
(0.81 to 0.89) aw 0.0058 aw
(0.89 to 0.94) aw 0.0065 aw
(0.94 to 0.96) aw 0.0074 aw
Temperature – (9 to 21) °C 0.09 °C Thermistor probe with digital
Measuring Equipment (21 to 25) °C 0.07 °C thermometer
(25 to 46) °C 0.09 °C
___________________________
1
This laboratory offers commercial calibration service.
2
Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3
The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
4
Uncertainty components that can be reasonably attributed to the Unit Under Test have not been utilized in
the calculation of the CMC value for this measurement parameter.
5
This scope meets A2LA’s P112 Flexible Scope Policy.
6
The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
(A2LA Cert. No. 5622.01) 11/11/2021 Page 2 of 2
Accredited Laboratory
A2LA has accredited
ROTRONIC INSTRUMENT CORPORATION
Hauppauge, NY
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General
requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of ANSI/NCSL
Z540-1-1994 and R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).