Product datasheet
Captair 1634 Smart
Ductless filtering chemical storage cabinets
Safer to operate
- Exclusive Erlab filtration technology
- Filtration performances tested in accordance with AFNOR NF X 15 211
- Secured storage
- Real time sensors to detect main filter saturation with solvents, acids or formaldehyde
- Erlab Safety Program: be guided for the right choice of your secured storage solutions
- Connected device allowing reception of safety notifications and use status
Simpler to use
Real time status communication by light and sound pulses:
- Door left open
- Main saturation
- Fan failure
Flexibility
- 2 possible configurations:
Double doors and shelves
Pull-out doors with storage trays
- Easy and fast relocation
Savings
- No ductwork cost
- Annual energy cost < 100
- Low replacement filter cost
Environment
- Pollutants filtered at source
Ask for the
highest level of
performances
Powerful light
guided
communication
Connect your equipment
and from the
remote access thanks to
our mobile solutions
Dowload our
eGuard application
Captair 1634 Smart
Ductless filtering chemical storage cabinets
Products handled / Applications
Version 1 – Double doors with shelves Liquid chemicals handlings Powders handlings
Liquid chemicals Liquid chemicals handlings in
and powders handlings clean room
1800mm1800mm 920mm920mm
670mm670mm Modular design of the
filtration column allows to Class I
Customized filtration column
adapt to every protection according
NA
1802mm 920mm to the
needs NF X 15-211
653mm
1800mm 1800mm 920mm 920mm
Class 2
670mm 670mm according
to the
min 2140 min
mm2140 mm NF X 15-211
max 2300mm
max 2300mm
min 2172 mm Available filters : Ventilation
max 2358mm
Carbon filtration for gases and vapours Particulate filtration for powders
Molecode
AS:For organic vapours HEPA H14:99.995 % efficiency filtration of particles over 0.1
Automatic alarm to
BE+:Polyvalent for acid + organic vapours µm in size
detect filter saturation
F:For formaldehyde vapours ULPA U17:99.999995 % efficiency filtration of particles over
min 2140 mm
min 2140 mm K:For ammonia vapours 0.1 µm in size
max 2300mmmax 2300mm
Filtration performances tested according to the AFNOR NF X 15-211:2009 standard : France
380mm
380mm Safety Standards
EN 1822 : 1998 (HEPA H14 & ULPA U17 Filters) - CE Marking
360mm
360mm
Air Flow 220 m3/h
Voltage/Frequency 80 - 220 V / 50-60 Hz
Power consumption/ 45 W / 0.45A
Max. amperage absorbed
380mm 380mm
1017mm
1017mm
Structure Corrosion resistant electro-galvanized steel coated with anti-acid polymer
1800mm1800mm
1800mm
670mm
670mm670mm
360mm 360mm Doors Clear, chemical resistant acrylic for easy viewing
1017mm
492mm Filtration Module Polypropylene
Storage capacity:
320 x 500mL bottles
Equipments
min
min2140 min
mm
2140 mm2140 mm 1017mm 1017mm Communication Audible and visible alarms by light pulses (LED) in case of:
max
max2300max
mm
2300 mm2300 mm
1800mm 1800mm interface -Door(s) left open -Ventilation problem -Filters saturation (Molecode)
670mm 670mm
Filtration technology 1 column that can be configured to handle liquids, powders, or both
Carbon filtration for
Following filtration column configuration (see above)
400mm
Shelf with integrated gases and vapours
400mm400mm
retention tray Particulate filtration for
Following filtration column configuration (see above)
min 2140 mm
min 2140 mm powders
max 2300 mm
max 2300 mm
App for remote control to monitor the hood, change the settings, and deliver safety alert immediately
eGuard
to your devices (mobile, tablet and PC)
380mm
Doors sensors Alarm if doors are left open
360mm
Chemical Listing List of approved chemicals
400mm 400mm
420mm
420mm420mm
Version 1 – Double doors with shelves
320mm
320mm320mm
Storage capacities up to 320 bottles (double doors )
Storage compartments 4
Delivered with 20 movable shelves with integrated retention tray
420mm
Absorbing mats 0
320mm
Lock Key lock
Options
Molecode Detection sensor for : Type S, for solvents / Type A, for acids / Type F, for formaldehydes
About Erlab
We provide safety, we protect your health
Erlab invented the ductless fume hood in 1968. With more than 50 years of experience in the of chemical and
protection of laboratory personnel; we know the formula for safety. With Erlab, you will never have to wonder or worry if our
products are safe. We build each one of the following 7 ingredients into our products, and without all of them, your health
and safety will be compromised.
1 Erlab R&D Laboratory
The engineers and chemists in our state-of-the-art R&D laboratory understand molecular We are committed to
designing products that are safe and of the highest quality, strive to improve our products, and continuously develop new
Captair Smart 483 V.05_02_2021 - Erlab France - Technical data are not contractual. Erlab reserves the right to modify the present document without prior notice.
products that provide greater protection in the laboratory.
2 Strict Safety Standards
We hold ourselves to the highest standard and adhere to the strict AFNOR NF X 15-211: 2009 safety standard
as endorsed by ANSI Z9.5-2012.
3 A Published Chemical Listing
It all begins here. Without this listing, we are not compliant with AFNOR NFX 15-211. Our in-house laboratory tests, as well
as independent testing, to verify the retention capacity of over 700 chemicals for our
4 Independent Testing
Erlab have been independently tested multiple times at various concentrations guaranteeing that our safety
solutions all adhere to the strict performance criteria of the AFNOR NF X 15-211:2009 standard assuring that the emission
concentration at the exhaust will always be lower than 1% of the TLV.
5 Application Questionnaire (Valiquest)
Our laboratory specialists will recommend the appropriate fume hood, type of and personalized advice.
6
A PhD chemist issues a of Validation with a list of the chemicals approved for use in the hood.
7 Our Safety Program
We back up our products 100%. This program includes your specialized chemical evaluation, validation of your hood
upon installation, and a safety specialist at your service to ensure that your hood is operating to its full potential.
France United States China Spain
+33 (0) 2 32 09 55 80 ventes@erlab.net +1 800-964-4434 captairsales@erlab.com +86 (0) 512 5781 4081 export.asia@erlab.com.cn +34 936 732 474 export.south@erlab.net
Germany United Kingdom Italy
0800 330 47 31 export.north@erlab.net +44 (0) 1722 341 940 export.north@erlab.net +39 (0) 2 89 00 771 export.south@erlab.net
www.erlab.com