DR 3900

The DR 3900™ Spectrophotometer is designed for accurate water analysis across various applications, including beverages and wastewater. It features guided procedures, flexible connectivity, and advanced technologies like RFID for sample tracking and hands-free updates. The device supports over 220 preprogrammed methods and offers extensive testing capabilities, ensuring reliable results in a user-friendly format.

Uploaded by

hamid akhoondi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
472 views4 pages

DR 3900

The DR 3900™ Spectrophotometer is designed for accurate water analysis across various applications, including beverages and wastewater. It features guided procedures, flexible connectivity, and advanced technologies like RFID for sample tracking and hands-free updates. The device supports over 220 preprogrammed methods and offers extensive testing capabilities, ensuring reliable results in a user-friendly format.

Uploaded by

hamid akhoondi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

DR 3900™ Spectrophotometer Applications

• Beverage
• Drinking Water
• Wastewater
• Food QC Lab
• Power

Prevent measurement errors...simply.


The proven technology you have come to expect from Hach just got better. Built with the future of water analysis in mind,
the DR 3900 will give consistently accurate results in a simpler testing format.

Guided Procedure Flexible Connectivity


The DR 3900 guides you step-by-step through the testing Built with 1 ethernet and 3 USB ports, the DR 3900 easily
procedure like a GPS, so you can get the accurate results connects to your computer and is programmed to easily
you need every time. interface with Hach WIMS™ or any LIMS system.
Elimination of False Readings Sample Tracking*
Scratched, flawed, or dirty glassware becomes a non-issue Sample bottles with smart tags can easily be tracked with
when your machine takes 10 readings and eliminates outliers. the optional Hach RFID sample-ID system, eliminating sample
mix-ups and providing better sample traceability.
Hands Free Updates*
RFID technology automatically updates the program calibration
factors when you place a TNTplus box near the machine. *RFID technology currently available in US,
Canada, Austrailia, and New Zealand only.
2 DR 3900™ Spectrophotometer

Specifications*
Operating Mode Transmittance (%), Absorbance Data Storage 2000 measured values (Result,
and Concentration, Scanning Date, Time, Sample ID, User ID)
(wavelength, time)
Preprogrammed > 220
Light Source Gas-filled Tungsten (visible) Methods
Optical System Reference beam, spectral User Programs 100
Wavelength Range 320 to 1100 nm Sample Cell 13 mm round, 16 mm round,
Compatibility 1 cm & 5 cm rectangular, 1" round,
Wavelength Accuracy ± 1.5 nm
1" rectangular
(wavelength range 340 to 900 nm)
Dimensions 151 mm x 350 mm x 255 mm
Wavelength ± 0.1 nm
(H x W X D)
Reproducibility
5.94 in x 13.78 in x 10.04 in
Wavelength Resolution 1 nm
Weight 4200 g
Wavelength Automatic when using stored or
Calibration barcode programs 9.26 lb
Wavelength Selection Automatic, based on method Operating Conditions 10 to 40 °C
selection
Storage Temperature -30 to 60 °C
Spectral Bandwidth 5 nm
Instrument Enclosure IP30
Photometric ± 3.0 Abs Rating
Measuring Range (wavelength range 340 to 900 nm)
Power Supply Benchtop power supply,
Photometric Accuracy 5 mAbs at 0.0 to 0.5 Abs 110 - 240 V; 50/60 Hz
1 % at 0.50 to 2.0 Abs Interfaces USB type A (2), USB type B,
Ethernet, RFID module
Photometric Linearity < 0.5 % to 2 Abs
≤ 1 % at > 2 Abs
Warranty 1 year
with neutral glass at 546 nm *Subject to change without notice.

Stray Light < 0.1 % T at 340 nm with NaNO2


Display 7" TFT
WVGA (800 pix x 480 pix)

Principle of Operation
Hach’s TNTplus chemistries
and spectrophotometers
are made to work
seamlessly with each other.
• Many of the tests are
EPA compliant.
• Over 35 tests available
including these popular
EPA Approved
Parameters:
- Ammonia
- COD
- Chlorine
- Chromium
- Iron
- Nitrate
- Nitrite
- Nitrogen
- Phosphorus
- Sulfate

www.hach.com
DR 3900™ Spectrophotometer 3

Available Tests
The following table lists available tests and overall ranges for the Hach DR 3900 Benchtop Spectrophotometer. The ranges may
represent more than one available test for the instrument. Consult your Hach representative, Customer Service, the Hach Master
Catalog, or the Hach web site at www.hach.com for complete details of all available tests for this instrument.

TNTplus TNTplus
Parameter Range Test Parameter Range Test
Alachlor 0.1 to 0.5 ppb, threshold Lead 3 µg/L to 2.0 mg/L •
Alkalinity, Total 25 to 400 mg/L • Manganese 0.006 to 20.0 mg/L
Aluminum 0.002 to 0.800 mg/L • Mercury 0.1 to 2.5 µg/L
Ammonia, Nitrogen 0.015 to 50.0 mg/L • Methylethylketoxime (MEKO) 15 to 1000 µg/L
Arsenic 0.020 to 0.200 mg/L Molybdenum, Molybdate 0.02 to 40.0 mg/L
Atrazine 0.5 to 3.0 ppb, threshold Nickel 0.006 to 6.0 mg/L •
Barium 2 to 100 mg/L Nitrate, Nitrogen 0.01 to 35 mg/L •
Benzotriazole 0.2 to 16.0 mg/L Nitrite, Nitrogen 0.002 to 250 mg/L •
Boron 0.2 to 14.0 mg/L Nitrogen, Simplified Total Kjeldahl 0 to 16 mg/L •
Bromine 0.05 to 4.50 mg/L Nitrogen, Total 0.5 to 150 mg/L •
Cadmium 1.3 µg/L to 0.30 mg/L • Nitrogen, Total Inorganic 0.2 to 25.0 mg/L
Carbohydrazide 5 to 600 µg/L Nitrogen, Total Kjeldahl 1 to 150 mg/L
Chloramine, Mono 0.04 to 10.0 mg/L Ozone 0.01 to 1.50 mg/L
Chloride 0.1 to 25.0 mg/L PCB (Polychlorinated Biphenyls) 1 to 50 ppm, threshold
Chlorine Dioxide 0.01 to 1000 mg/L Phenols 0.002 to 0.200 mg/L
Chlorine, Free 0.02 to 10.0 mg/L • Phosphonates 0.02 to 125.0 mg/L
Chlorine, Total 2 µg/L to 10.0 mg/L • Phosphorus, Acid Hydrolyzable 0.06 to 100.0 mg/L
Chromium, Hexavalent 0.010 to 1.00 mg/L • Phosphorus, Reactive (Orthophosphate) 19 µg/L to 100.0 mg/L •
Chromium, Total 0.01 to 0.70 mg/L • Phosphorus, Total 0.06 to 100.0 mg/L •
Cobalt 0.01 to 2.00 mg/L Potassium 0.1 to 7.0 mg/L
Color 3 to 500 units Quaternary Ammonium Compounds 0.2 to 5.0 mg/L
COD (Chemical Oxygen Demand) 0.7 to 15,000 mg/L • Selenium 0.01 to 1.00 mg/L
Copper 1 µg/L to 8.0 mg/L • Silica 3 µg/L to 100 mg/L
Cyanide 0.002 to 0.240 mg/L Silver 0.005 to 0.700 mg/L
Cyanuric Acd 5 to 50 mg/L Sulfate 2 to 900 mg/L •
DEHA (Diethylhydroxylamine) 3 to 450 µg/L Sulfide 5 to 800 µg/L
Dissolved Oxygen 6 µg/L to 40 mg/L Surfactants, Anionic 0.002 to 0.275 mg/L
Erythorbic Acid (Isoascorbic acid) 13 to 1500 µg/L Suspended Solids 5 to 750 mg/L
Fluoride 0.02 to 2.00 mg/L Tannin and Lignin 0.1 to 9.0 mg/L
Formaldehyde 2 to 500 µg/L TOC (Total Organic Carbon) 0.3 to 700 mg/L
Hardness, Total 4 µg/L to 4.00 mg/L Tolyltriazole 1.0 to 20.0 mg/L
(Calcium and Magnesium as CaCO3) Toxicity 0 to 100% Inhibition
Hydrazine 4 to 600 µg/L TTHM (Trihalomethanes, Total) 10 to 600 µg/L
Hydroquinone 9 to 1000 µg/L TPH (Total Petroleum Hydrocarbons) 2 to 200 ppm, threshold
Iodine 0.07 to 7.00 mg/L Volatile Acids 27 to 2800 mg/L •
Iron, Ferrous 0.02 to 3.00 mg/L Zinc 0.01 to 3.00 mg/L
Iron, Total 0.009 to 6.0 mg/L •

www.hach.com
4 DR 3900™ Spectrophotometer

Ordering Information
DR 3900 Benchtop Spectrophotometer; includes adapter "A" for 1" round +
AccuVac/1 cm rectangular cuvettes, manual, CD with manual and procedure manual
in .pdf format. Power Supply. RFID version available in US, Canada, Australia and
New Zealand.
LPV440.99.00012 DR 3900 Spectrophotometer with RFID Technology, 110 - 240V

LPV440.99.00002 DR 3900 Spectrophotometer without RFID Technology,


110 - 240V
Accessories

LZV537 Test Filter Set

LZV873 Ethernet Cable

LZV566 USB Barcode Scanner

LZV582 USB Keyboard

2960100 Citizen PD-24 USB Printer Package

Service Options

Comprehensive warranty upgrade includes: All parts, labor, and shipping costs from
the factory for depot repairs. One calibration per year on-site, factory recommended
maintenance (including required parts), unlimited technical support calls. Also includes
a loaner* while waiting for your factory repair. Please see service terms and conditions
for additional details.
*Based on availability

WRTUPGDR3900 DR 3900 WarrantyPlus Instrument Protection and Service

HACH COMPANY World Headquarters: Loveland, Colorado USA


United States: 800-227-4224 tel 970-669-2932 fax orders@hach.com
Outside United States: 970-669-3050 tel 970-461-3939 fax int@hach.com
www.hach.com

LIT2667 Rev 1
E113 Printed in U.S.A.
©Hach Company, 2011. All rights reserved.
In the interest of improving and updating its equipment, Hach Company reserves the right to alter specifications to equipment at any time.