0% found this document useful (0 votes)
14 views4 pages

VLB - 014179 (Eng)

The document provides a data sheet for the 3RM1001-1AA04 motor starter, detailing its specifications including operating voltage, current ratings, and environmental conditions. It features electronic overload protection, is suitable for various installation altitudes, and has specific requirements for electrical connections. Additional resources for product information and support are also provided.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views4 pages

VLB - 014179 (Eng)

The document provides a data sheet for the 3RM1001-1AA04 motor starter, detailing its specifications including operating voltage, current ratings, and environmental conditions. It features electronic overload protection, is suitable for various installation altitudes, and has specific requirements for electrical connections. Additional resources for product information and support are also provided.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Product data sheet 3RM1001-1AA04

MOTOR STARTER 3RM1 SIRIUS DIRECT STARTER 500


V,
0,1-0,5 A,
24 V DC SCREW-TYPE CONNECTION SYSTEM

General technical data:


product designation Motor starter

Design of the product with electronic overload protection

Protection class IP IP20

Suitability for use / device connector 3ZY12 Yes

Installation altitude / at a height over sea level / maximum m 4,000

Ambient temperature

• during operating °C -25 … +60

• during transport °C -40 … +70

• during storage °C -40 … +70

Resistance against shock 6g / 11 ms

Resistance against vibration 1 ... 6 Hz, 15 mm; 20 m/s², 500 Hz

Impulse voltage resistance / rated value kV 6

Conductor-bound parasitic coupling conductor-conductor 1 kV


SURGE / according to IEC 61000-4-5

Conductor-bound parasitic coupling BURST / according to IEC 2 kV / 5 kHz


61000-4-4

Conducted interference as high-frequency radiation according 10 V


to IEC 61000-4-6

Electrostatic discharge / according to IEC 61000-4-2 4 kV contact discharge / 8 kV air discharge

3RM1001-1AA04 subject to modifications


Page 1/ 4 02/05/2013 © Copyright Siemens AG 2013
Field-bound HF-interference emission / according to CISPR11 Class B for the domestic, business and commercial
environments

Conductor-bound HF-interference emission / according to Class B for the domestic, business and commercial
CISPR11 environments

Insulation voltage / rated value V 600

Safety:
Safety device type / according to IEC 61508-2 Type B

Main circuit:
Operating voltage / rated value / maximum V 500

Operating frequency

•1 Hz 50

•2 Hz 60

Operating current / at 400 V / for AC / rated value A 0.5

Minimum load in % of l_M % 20

Active power loss / typical W 0.02

Adjustable response current

• of the current-dependent overload release A 0.1 … 0.5

Service power / for three-phase servomotors / at 400 V

• at 50 Hz kW 0 … 0.12

Control circuit:
Type of voltage / of the controlled supply voltage DC

Control supply voltage / 1

• for DC / rated value V 24

Operating range factor control supply voltage rated value

• for DC 0.8 … 1.25

Control current A 0.08

Input voltage / at the digital input / with signal <1>

• for DC V 19.2 … 30

Input current / at the digital input / for signal <1> / typical A 0.01

Installation/mounting/dimensions:
mounting position vertical, horizontal

Width mm 22.5

Height mm 100

Depth mm 141.6

Connections:
Design of the electrical connection

• for main current circuit screw-type terminals

3RM1001-1AA04 subject to modifications


Page 2/ 4 02/05/2013 © Copyright Siemens AG 2013
• for auxiliary and control current circuit screw-type terminals

Type of the connectable conductor cross-section

• for main contacts

• solid 1x (0.2 ... 4 mm²), 2x (0.2 ... 2.5 mm²)

• finely stranded

• with conductor end processing 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 2.5 mm²)

• for AWG conductors 1x (20 ... 12), 2x (20 ... 14)

Type of the connectable conductor cross-section

• for auxiliary contacts

• finely stranded

• with conductor end processing 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1 mm²)

• for AWG conductors 1x (20 ... 14), 2x (20 ... 16)

Certificates/approvals:
General Product Approval Declaration of Test Certificates
Conformity

Type Test
Certificates/Test
Report

Further information:
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/industrial-controls/catalogs

Industry Mall (Online ordering system)


http://www.siemens.com/industrial-controls/mall

Cax online generator


http://www.siemens.com/cax

Service&Support (Manuals, Certificates, Characteristics, FAQs,...)


http://support.automation.siemens.com/WW/view/en/3RM1001-1AA04/all

Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3RM1001-1AA04

3RM1001-1AA04 subject to modifications


Page 3/ 4 02/05/2013 © Copyright Siemens AG 2013
last change: Feb 4, 2013

3RM1001-1AA04 subject to modifications


Page 4/ 4 02/05/2013 © Copyright Siemens AG 2013