PRODUCT DATA

3 03 35 00 Concrete
Finishing
LUMIPLATE™
Ferrosilicon nonoxidizing metallic-aggregate
dry-shake surface hardener

Description Features Benefits


Lumiplate™ is a ferrosilicon • Nondusting Improves the wear of concrete surfaces
nonoxidizing metallic-aggregate • Nonoxidizing Will not rust or corrode floors even in constantly wet
surface hardener. It is ideal for conditions
industrial floors requiring added
• Ready to use No jobsite measuring or mixing required
abrasion and impact resistance where
moisture or humidity may be a factor. • Abrasion resistance 3 – 4 times greater than Handles heavy and frequent traffic
Lumiplate™ is also available in a light- mineral-aggregate hardeners and toppings
reflective formula. • Impact resistance is twice that of plain concrete Ideal for loading and shipping environments
• Application rates from 1.5 to 2.5 lbs/ft 2
Adaptable to varying jobsite conditions and
Yield (7.3 to 12.2 kg/m2) performance requirements
Approximately 1.5 – 2.5 lb/ft2 • Smooth or slip-resistant finishes Suitable for a variety of flooring needs
(7.3 – 12.2 kg/m2). Do not apply more • Greater surface density than concrete Decreases penetration by oils and chemicals; makes
than 1 lb/ft2 in a single pass. Consult maintenance easier and less expensive
your BASF representative for specific • Light reflective Conserves energy; increases the light-reflectivity
recommendations. of floors
Packaging • Specially sized and graded ferrosilicon Provides consistent finishing characteristics and
55 lb (25 kg) multi-wall bags metallic aggregate uniformity from lot to lot
No further measuring or mixing of the
ingredients is required at the jobsite.
Where to Use How to Apply
Color
APPLICATION Application
Slate, light reflective, and natural
• When metallic-aggregate surface hardeners must Contact your local representative for a pre-job
Shelf Life withstand wet conditions conference to review the concrete mix design and
18 months when properly stored • For commercial and industrial floors subject to additives and carefully plan each step of the
Storage deicing salts installation.
Store in unopened packaging in a • Where light-reflective flooring is desired Refer to the Masterplate® 200 product data sheet for
clean, dry environment protected from details on the application of Lumiplate™ surface
• Floors subject to heavy or frequent traffic
sunlight at 50 to 90° F (10 to 32° C). hardener.
• Salt-storage facilities
• Multi-purpose sporting facilities
• Recreational facilities
LOCATION
• Indoor applications
• Over freshly placed concrete

Protection and Repair


MBT PROTECTION & REPAIR PRODUCT DATA
LUMIPLATE™

Curing Health and Safety Waste Disposal Method


1. After final troweling and when the surface can no LUMIPLATE ™
This product contains materials listed by the State of
longer be marred, apply an approved BASF DANGER - CORROSIVE California as known to cause cancer, birth defects or
membrane-forming curing compound in accordance other reproductive harm.
with directions. For VOC-compliance consult your Lumiplate™ contains magnesium fluorosilicate,
sulfuric acid. Proposition 65
local BASF representative for recommendations
Risks This product contains materials listed by the state of
for other curing methods.
California as known to cause cancer, birth defects, or
2. Light-reflective floors require extra care during Contact with skin or eyes may cause burns. reproductive harm.
construction. Protect the newly constructed floor Ingestion may cause irritation and burns of mouth,
throat and stomach. Inhalation of vapors may cause VOC Content
from staining and damage until the structure goes
into service. irritation and intoxication with headaches, dizziness 0 g/L or 0 lbs/gal less water and exempt solvents.
and nausea. INTENTIONAL MISUSE BY
DELIBERATELY INHALING THE CONTENTS MAY BE
For Best Performance For medical emergencies only,
HARMFUL OR FATAL.
call ChemTrec (1-800-424-9300).
• Do not use on floors exposed to acids, their salts, Precautions
or similar materials that seriously and rapidly
attack Portland cement. DO NOT get in eyes, on skin or clothing. Wash
thoroughly after handling. Keep container closed. DO
• Do not apply over concrete containing more than NOT take internally. Use only with adequate
3% air content when tested by ASTM C 173, ventilation. DO NOT breathe vapors. Use impervious
ASTM C 231, or ASTM C 138 procedures. gloves, eye protection and if the TLV is exceeded or
• Never burnish-trowel a light-reflective surface used in a poorly ventilated area, use NIOSH/MSHA
hardener. approved respiratory protection in accordance with
• Use cleaning agents with a high alkaline content applicable Federal, state and local regulations.
for continuous maintenance programs. First Aid
• Do not place dry shake on slab without a roof In case of eye contact, flush thoroughly with water
cover. for at least 15 minutes. In case of skin contact,
• Many factors can affect the final shade and wash affected areas with soap and water. If irritation
appearance of a concrete floor. BASF cannot be persists, SEEK MEDICAL ATTENTION. Remove and
held responsible for poor workmanship, wash contaminated clothing. If inhalation causes
inadequate protection, or other matters beyond physical discomfort, remove to fresh air. If
our control. discomfort persists or any breathing difficulty occurs
or if swallowed, SEEK IMMEDIATE MEDICAL
• Make certain the most current versions of
ATTENTION.
product data sheet and MSDS are being used;
call Customer Service (1-800-433-9517) to
verify the most current version.
• Proper application is the responsibility of
the user. Field visits by BASF personnel
are for the purpose of making technical
recommendations only and not for supervising
or providing quality control on the jobsite.

BASF Construction Chemicals, LLC – LIMITED WARRANTY NOTICE Every reasonable effort is made to apply BASF exacting standards both in the manufacture of our products and in the information which we issue concerning these products and their use. We
warrant our products to be of good quality and will replace or, at our election, refund the purchase price of any products proved defective. Satisfactory results depend not only upon quality products, but also upon many factors
Building Systems beyond our control. Therefore, except for such replacement or refund, BASF MAKES NO WARRANTY OR GUARANTEE, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR
MERCHANTABILITY, RESPECTING ITS PRODUCTS, and BASF shall have no other liability with respect thereto. Any claim regarding product defect must be received in writing within one (1) year from the date of shipment. No claim
will be considered without such written notice or after the specified time interval. User shall determine the suitability of the products for the intended use and assume all risks and liability in connection therewith. Any
889 Valley Park Drive authorized change in the printed recommendations concerning the use of our products must bear the signature of the BASF Technical Manager.
Shakopee, MN, 55379 This information and all further technical advice are based on BASF’s present knowledge and experience. However, BASF assumes no liability for providing such information and advice including the extent to which such information and
advice may relate to existing third party intellectual property rights, especially patent rights. In particular, BASF disclaims all CONDITIONS AND WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES
OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY. BASF SHALL NOT BE RESPONSIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. BASF reserves
www.BuildingSystems.BASF.com the right to make any changes according to technological progress or further developments. It is the customer’s responsibility and obligation to carefully inspect and test any incoming goods. Performance of the product(s) described herein
should be verified by testing and carried out only by qualified experts. It is the sole responsibility of the customer to carry out and arrange for any such testing. Reference to trade names used by other companies is neither a recommendation,
Customer Service 800-433-9517 nor an endorsement of any product and does not imply that similar products could not be used.
Form No. 1019524 7/07 © 2007 BASF
Technical Service 800-243-6739 For professional use only. Not for sale to or use by the general public. Printed on recycled paper including 10% post-consumer fiber. Printed in U.S.A.