Iec Test Report

The CE test report for the refrigeration unit model PJL-100, supplied by Huayi Compressor (Jingzhou) Co., Ltd, confirms that the product passed all relevant safety standards as per IEC specifications. The tests were conducted on April 12, 2025, and included assessments for household and similar electrical appliances, specifically focusing on motor-compressors and commercial refrigerating appliances. The report indicates compliance with safety requirements, with no deviations or failures noted during the testing process.

Uploaded by

karim.m
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
429 views42 pages

Iec Test Report

The CE test report for the refrigeration unit model PJL-100, supplied by Huayi Compressor (Jingzhou) Co., Ltd, confirms that the product passed all relevant safety standards as per IEC specifications. The tests were conducted on April 12, 2025, and included assessments for household and similar electrical appliances, specifically focusing on motor-compressors and commercial refrigerating appliances. The report indicates compliance with safety requirements, with no deviations or failures noted during the testing process.

Uploaded by

karim.m
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 42

CE TEST REPORT FOR REFRIGERATION UNIT

Supplier: Huayi Compressor (Jingzhou) Co., Ltd

TEST DATE: April 12, 2025


Technical specification:
Test Report Number: HYTR20250412-01

Supplier: Huayi Compressor (Jingzhou) Co., Ltd

Tested Products: Refrigeraiton Unit for Beer Cooler

Model Number: PJL-100

Test Specification:
IEC60335-1: 2020: Household and similar electrical appliances - Safety - Part 1: General requirements
IEC 60335-2-34: 2021 Household and similar electrical appliances – Safety - Part 2-34: Particular
requirements for motor-compressor
IEC60335-2-89: 2021 Household and similar electrical appliances - Safety - Part 2-89: Particular
requirements for commercial refrigerating appliances with an incorporated or remote refrigerant unit or
compressor

Test Resulit: Pass

TEST REPORT
Test specification
Standard: IEC60335-1: 2020: Household and similar electrical appliances - Safety - Part 1: General
requirements
IEC 60335-2-34: 2021 Household and similar electrical appliances – Safety - Part 2-34: Particular
requirements for motor-compressor
IEC60335-2-89: 2021 Household and similar electrical appliances - Safety - Part 2-89: Particular
requirements for commercial refrigerating appliances with an incorporated or remote refrigerant unit or
compressor
Test procedure : CB Scheme
Procedure deviation : N.A.
Non-standard test method : N.A.
............................................................ :
Test Report Form No. : EN 60335_1/ EN 60335_2_34/ EN 60335_2_89
Master TRF : Dated April 2025

1 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Test item particulars : Refrigeration unit for beer cooler


Classification of installation and use :I
Supply Connection : Not intended for direct connection of the appliance
supply cord to the motor-compressor terminals
Application category : MBP
Cooling : Fan
Refrigerant identification : R290
Protection system (1), if present : Thermal motor protector
Protection system (2) : Self-resetting
Control system (starting control functions devices) : Relay
Control system (cooling capacity control functions) : No
Electronic circuit : No
Start capacitor : Yes
Run capacitor : No
Fixed speed : Yes
Variable speed : No

Possible test case verdicts


Test case does not apply to the test object : N/A
Test item does meet the requirement : P(Pass)
Test item does not meet the requirement : F(Fail)

Product Photo:

2 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

5 GENERAL CONDITIONS FOR THE TESTS P


P
Tests performed according to cl. 5, e.g. nature
of supply, sequence of testing, etc.
5.2 At least one additional sample is required for P
the test of clause 19, however further samples
may also be provided or are needed
5.7 Tests are carried out in an ambient N/A
temperature of 20℃±5℃
5.8.2 Motor-compressors with self-resetting motor- P
compressor protection systems and designed
for more than one rated voltage are subjected
to the tests of 19.101 & 19.103 at the highest
voltage
5.11 For motor-compressors which can be used in P
appliances where the supply cord is connected
directly to terminals on the motor-compressor
the test sample shall be provided with a supply
cord
Motor-compressors including those with crank-
5.101 case heaters are tested as motor-operated P
appliances.

6 CLASSIFICATION P
6.1 Protection against electric shock: Class I, II, P
Class I
III .........................................................:
6.2 Degree of protection against harmful ingress of IPX0 P
water (IP degree in accordance with IEC 529)
6.101 Motor-compressors are classifed as being P
With Annex AA
tested with Annex AA or without Annex AA
6.102 Motor compressors are classified as being: P
-intended for direct connection of the appliance
supply cord to the motor-compressor terminal
Not intended for direct
or
connection
-not intended for direct connection of the
appliance supply cord to the motor-compressor
terminals.

7 MARKING P
7.1 Rated voltage or voltage range (V) ................... : AC 220~240 P
Symbol of nature of supply ................................ : 1-phase P
Rated frequency or frequency range (Hz) ........ : 50Hz P
Rated power input (W) ...................................... : P

3 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Rated current (A) ............................................... : P


Manufacturer's name or responsible vendor's Huayi P
name .................................................................. :

Trademark or identification mark........................ : Huayi P

Model or type reference: ..................................... P

Symbol for class II ............................................. : N/A


IP number .......................................................... : N/A
7.2 Warning for stationary appliances for multiple N/A
supply
Warning placed in vicinity of terminal cover N/A

7.3 Range of rated values marked with the lower P


and upper limits separated by a hyphen

Different rated values marked with the values N/A


separated by an oblique stroke

7.4 Appliances adjustable for different rated P


voltages, the voltage setting is clearly
discernible

7.5 Appliances with more than one rated voltage or P


one or more rated voltage ranges, marked with
rated input or rated current for each rated
voltage or range, unless

the power input is related to the mean value of P


the rated voltage range

Relation between marking for upper and lower P


limits of rated power input or rated current and
voltage is clear

7.6 Correct symbols used P

7.77.7 Connection diagram fixed to appliances to be N/A


connected to more than two supply conductors
& appliances for multiple supply
7.8 Except for type Z attachment, terminals for connection to the supply mains indicated -----
as follows:

- marking of terminals exclusively for the neutral N/A


conductor (N)

- marking of protective earthing terminals Indicated by symbol 5019 of P


(symbol 5019 of IEC 60417) IEC 60417

4 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

7.9 Marking or placing of switches which may cause N/A


a hazard

7.10 Indications of switches on stationary appliances N/A


and controls on all appliances by use of figures,
letters or other visual means
7.11 Indication for direction of adjustment of controls N/A

7.12 Instructions for safe use provided P

7.13 Instructions and other texts in an official P


language
7.14 Marking clearly legible and durable P

7.15 Marking on a main part P

7.16 Marking of a possible replaceable thermal link or N/A


fuse link clearly visible with regard to replacing
the link

8 PROTECTION AGAINST ACCESS TO LIVE PARTS P

8.1 Adequate protection against accidental contact P


with live parts
8.1.2 Requirement applies for all positions, P
detachable parts removed
Use of test probe B of IEC 61032: no contact N/A
with live parts
Use of test probe 13 of IEC 61032 through N/A
openings in class 0 appliances and class II
appliances/constructions: no contact with live
parts
8.1.3 For appliances other than class II, use of test N/A
probe 41 of IEC 61032: no contact with live
parts of visible glowing heating elements

8.2 Class II appliances and constructions N/A


constructed so that there is adequate protection
against accidental contact with basic insulation
and metal parts separated from live parts by
basic insulation only

9 STARTING OF MOTOR-OPERATED APPLIANCE N/A


This clause of Part 1 is not applicable N/A

5 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

10 POWER INPUT AND CURRENT N/A


This clause of Part 1 is not applicable N/A

11 HEATING N/A

This clause of Part 1 is not applicable N/A

13 LEAKAGE CURRENT & ELECTRIC STRENGTH AT OPERATING TEMPERATURE P

13.1 Leakage current not too excessive and electric This clause of Part 1 is not N/A
strength adequate applicable
13.2 Leakage current measured by means of circuit This clause of Part 1 is not N/A
described in Annex G applicable
Leakage current measurements This clause of Part 1 is not N/A
applicable
13.3 Electric strength tests according to table 4 P

No breakdown during the test P

14 TRANSIENT OVERVOLTAGES N/A

Appliances withstand the transient over- Comply with clause 29 N/A


voltages to which they may be subjected
Clearances having a value less than specified N/A
in table 16 subjected to an impulse voltage
test, the test voltage specified in table 6
No flashover during the test, unless of N/A
functional insulation
In case of flashover of functional insulation, N/A
the appliance complies with clause 19 with the
clearance short circuited

15 MOISTURE RESISTANCE N/A

15.1 Electrical components protected against ingress N/A


of water
Compliance checked as specified in 15.1.1, N/A
taking into account 15.1.2, followed by the
electric strength test of 16.3

No trace of water on insulation which can result N/A


in a reduction of clearances and creepage
distances below values specified in clause 29

6 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Appliances, other than IPX0, subjected to tests IPX0 N/A


as specified in IEC 60529

15.2 Spillage of liquid does not affect the electrical N/A


insulation

Overfilling test with additional amount of water, N/A


over a period of 1 min

The appliance withstands the electric strength N/A


test of 16.3
No trace of water on insulation that can result in N/A
a reduction of clearances and creepage
distances below values specified in clause 29
15.3 Humidity test P

Relative humidity of (93±2)%, 48h P

Withstand the test of clause 16 P

16 LEAKAGE CURRENT AND ELECTRIC STRENGTH P

16.1 No excessive leakage current and adequate Performed after tests of clause P
insulation and electric strength (tests 16.2 and 15 and sub-clause
16.3)
16.2 Leakage current measurements P

16.3 Electric strength tests according to table7 P

17 OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS N/A

The transformer is same as that used in the approved one. N/A

No excessive temperatures in transformer or N/A


associated circuits in event of short-circuits likely
to occur in normal use
Appliance supplied with 1.06 or 0.94 times rated N/A
voltage and the most unfavourable short-circuit or
overload likely to occur in normal use applied
Temperature rises of insulation of the conductors No safety extra low voltage N/A
of safety extra-low voltage circuits not exceeding circuit
the relevant value specified in table 3 by more
than 15 K
Temperature of the winding not exceeding the N/A
value specified in table 6

7 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

18 ENDURANCE N/A

This clause of Part 1 not applicable N/A

19 ABNORMAL OPERATION P

19.1 The risk of fire or mechanical damage under P


abnormal or careless operation obviated

Electronic circuits so designed and applied that a P


fault will not render the appliance unsafe
Motor-compressors are submitted to the tests of P
19.101,19.102,19.103 and additionally if so
required by the classification of 6.101 to the tests
specified in Annex AA
Motor-compressors incorporating electronic N/A
circuits are also subjected to the tests of 19.11
and 19.12
Tests of clauses 19.2 to 19.10 not applicable P

19.11 Electronic circuits, compliance checked by N/A


evaluation of the fault conditions specified in
19.11.2 for all circuits or parts of circuits, unless
they comply with the conditions specified in
19.11.1

19.11.1 Before applying the fault conditions a) to g) in 19.11.2, it is checked if circuits or parts N/A
of circuit meet both of the following conditions:
- the electronic circuit is a low-power circuit, that N/A
is, the maximum power at low-power points does
not exceed 15 W according to the tests specified
- the protection against electric shock, fire hazard, N/A
mechanical hazard or dangerous malfunction in
other parts of the appliance does not rely on the
correct functioning of the electronic circuit
19.11.2 Fault conditions applied one at a time, the appliance operated under conditions
specified in Cl. 11, but supplied at rated voltage, the duration of the tests as specified:
a) short-circuit of creepage distances and N/A
clearances between live parts of different
potential, if these distances are less than the
values specified in 29.1, unless the relevant part
is adequately encapsulated
b) open circuit at the terminals of any component N/A
c) short-circuit of capacitors, unless they comply N/A
with IEC 60384-14 or subclause 14.2 of
IEC 60065

8 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

d) short-circuit of any two terminals of an N/A


electronic component, other than integrated
circuits. This fault condition is not applied
between the circuits of an optocoupler
e) failure of triacs in the diode mode N/A
f) failure of an integrated circuit. In this case the N/A
possible hazardous situations of the appliance
are assessed to ensure that safety does not rely
on the correct functioning of such a component
During and after each test the following is checked: N/A
- the temperature rise of the windings do not N/A
exceed the values specified in table 6
- the appliance complies with the conditions N/A
specified in 19.13
- live parts not accessible to the test finger or test N/A
pin as specified in Cl. 8
- any current flowing through protective No protective impedance N/A
impedance not exceeding the limits specified in
8.14
If a conductor of a printed board becomes open circuited, the appliance is considered N/A
to have withstood the particular test, provided all three of the following conditions are
met:
- the material of the printed circuit board N/A
withstands the burning test of sub clause 20.1 of
IEC 60065
- any loosened conductor does not reduce the N/A
creepage distances or clearances between live
part and accessible metal parts
- the appliance withstands the tests of 19.11.2 N/A
with open circuited conductor bridged
19.12 If the safety of the appliance for any of the fault N/A
conditions specified in 19.11.2 depends on the
operation of a miniature fuse-link complying with
IEC 60127, the test is repeated, measuring the
current flowing through the fuse-link; measured
current (A); rated current of the fuse-link (A) ........ :
19.13 During the tests the appliance does not emit Not emitted. P
flames, molten metal, poisonous or ignitable gas
in hazardous amounts
Temperature rises not exceeding the values Well below the limits. P
shown in table 7
Enclosures not deformed to such an extent that No deformation. P
compliance with the standard is impaired
Appliance, withstands the electric strength test of 16.3, however, the test voltage
being:

9 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

- basic insulation: 1 000 V Between supply and protective P


earth.
- supplementary insulation: 1750 V N/A

- reinforced insulation: 3000 V N/A

19.101 Test locked-rotor the motor-compressor and P


motor-compressor protection system
19.102 Repeat test clause 19-101 with start and run P
capasitors
19.103 Test locked-rotor the three-phase motor- N/A
compressor and motor-compressor protection
system
19.104 During the tests the appliance, the motor- P
compressor protection system shall be able to
operate, Chamber temperature and levels
available shall not exceed 150◌ْc
19.105 Three-phase motor-compressors shall be N/A
adequately protected against primary single-
phase failure

20 STABILITY AND MECHANICAL HAZARDS P

20.1 Adequate stability N/A

20.2 Moving parts adequately arranged or enclosed as P


to provide protection against personal injury

Protective enclosures, guards and similar parts P


are non-detachable

Adequate mechanical strength and fixing of P


protective enclosures

Not possible to touch dangerous moving parts P


with test probe

21 MECHANICAL STRENGTH P

21.1 Appliance has adequate mechanical strength and P


is constructed as to withstand rough handling

Checked by applying blows to the appliance in P


accordance with test Ehb of IEC 60068-2-75,
spring hammer test, impact energy 0,5 J

10 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

If necessary, supplementary or reinforced P


insulation subjected to the electric strength test of
16.3
If necessary, repetition of groups of three blows N
on a new sample

21.2 Accessible parts of solid insulation having P


strength to prevent penetration by sharp
implements

The insulation is tested as specified, unless P


the thickness of supplementary insulation is at N/A
least 1 mm and reinforced insulation is at least 2
mm

22 CONSTRUCTION P

22.1 Appliance marked with the first numeral of the IP IPX0 (ordinary) N/A
system, relevant requirements of IEC 60529 are
fulfilled
22.2 Stationary appliance: means to provide all-pole disconnection from the supply N/A
provided, the following means being available:
- a supply cord fitted with a plug N/A
- a switch complying with 24.3 N/A
- a statement in the instruction sheet that a P
disconnection incorporated in the fixed wiring is
to be provided
- an appliance inlet N/A

22.3 Appliance provided with pins: no undue strain on No pins N/A


socket-outlets

22.4 Appliance for heating liquids and appliance N/A


causing undue vibration not provided with pins
for insertion into socket-outlets

22.5 No risk of electric shock when touching the pins This clause of Part 1 is not N/A
of the plug, the appliance being disconnected applicable
from the supply at the instant of voltage peak.

22.6 Electrical insulation not affected by condensing N/A


water or leaking liquid

22.7 Housings shall withstand the pressures expected P


in normal use.

22.8 Electrical connections not subject to pulling N/A


during cleaning of compartments to which
access can be gained without the aid of a tool,
and that are likely to be cleaned in normal use

11 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

22.9 Insulation, internal wiring, windings, P


commutators
and slip rings not exposed to oil, grease or
similar
substances
Adequate insulating properties of oil or grease to P
which insulation is exposed

22.10 Not possible to reset voltage-maintained non- P


selfresetting thermal cut-outs by the operation of
an automatic switching device incorporated
within the appliance
22.11 Reliable fixing of non-detachable parts that complied P
provide the necessary degree of protection
against electric shock, moisture or contact with
moving parts
22.12 Handles, knobs etc. fixed in a reliable manner No such hazard part N/A

22.13 Unlikely that handles, when gripped as in normal N/A


use, make the operators hand touch parts
having a temperature rise exceeding the value
specified for handles which are held for short
periods only
22.14 No ragged or sharp edges creating a hazard for This clause of Part 1 is not N/A
the user in normal use, or during user applicable
maintenance
No exposed pointed ends of self tapping screws N/A
etc., liable to be touched by the user in normal
use or during user maintenance
22.15 Storage hooks and the like for flexible cords N/A
smooth and well rounded

22.16 Automatic cord reels cause no undue abrasion N/A


or
damage to the sheath of the flexible cord, no
breakage of conductors strands, no undue wear
of contacts
22.17 Spacers not removable from the outside by hand No spacers N/A
or by means of a screwdriver or a spanner

22.18 Current-carrying parts and other metal parts P


resistant to corrosion under normal conditions of
use
22.19 Driving belts not used as electrical insulation No driving belts N/A

22.20 Direct contact between live parts and thermal N/A


insulation effectively prevented, unless material
used is non-corrosive, non-hygroscopic and
noncombustible
22.21 Wood, cotton, silk, ordinary paper and fibrous or P
hygroscopic material not used as insulation,
unless impregnated

12 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

22.22 Appliances not containing asbestos No asbestos P

22.23 Oils containing polychlorinated biphenyl (PCB) No PCB P


not used

22.24 Bare heating elements adequately supported N/A

22.25 Sagging heating conductors cannot come into N/A


contact with accessible metal parts

22.26 The insulation between parts operating at safety N/A


extra-low voltage and other live parts complies
with the requirements for double or reinforced
insulation
22.27 Parts connected by protective impedance N/A
separated by double or reinforced insulation

22.28 Metal parts of Class II appliances conductively N/A


connected to gas pipes or in contact with water:
separated from live parts by double or reinforced
insulation
22.29 Class II appliances permanently connected to N/A
fixed wiring so constructed that the required
degree of access to live parts is maintained after
installation
22.30 Parts serving as supplementary or reinforced N/A
insulation fixed so that they cannot be removed
without being seriously damaged,
22.31 Clearances and creepage distances over complied P
supplementary and reinforced insulation not
reduced below values specified in clause 29 as a
result of wear
22.32 Supplementary and reinforced insulation complied P
designed or protected against deposition of dirt
or dust
22.33 Conductive liquids that are or may become N/A
accessible in normal use are not in direct contact
with live parts
22.34 Shafts of operating knobs, handles, levers etc. No such shafts N/A
not live, unless the shaft is not accessible when
the part is removed
22.35 Handles, levers and knobs, held or actuated in N/A
normal use, not becoming live in the event of an
insulation fault
22.36 Handles continuously held in the hand in normal No handles N/A
use are so constructed that when gripped as in
normal use, the operators hand is not likely to
touch metal parts, unless they are separated
from live parts by double or reinforced insulation
22.37 Capacitors in Class II appliances not connected Class I appliance N/A
to accessible metal parts, unless complying with
22.42

13 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

22.38 Capacitors not connected between the contacts P


of a thermal cut-out

22.39 Lamp holders used only for the connection of No lamp holders N/A
lamps

22.40 Motor-operated appliances and combined N/A


appliances intended to be moved while in
operation, or having accessible moving parts,
fitted with a switch to control the motor. The
actuating member of the switch being easily
visible and accessible
22.41 No components, other than lamps, containing N/A
mercury

22.42 Protective impedance consisting of at least two N/A


separate components

22.43 Appliances adjustable for different voltages, P


accidental changing of the setting of the voltage
unlikely to occur
22.44 Appliances are not allowed to have an enclosure P
that is shaped and decorated so that the
appliance is likely to be treated as a toy by
children
22.45 When air is used as reinforced insulation, N/A
clearances not reduced below the values
specified in 29.1.4 due to deformation as a result
of an external force applied to the enclosure
22.46 Software used in protective electronic circuits is N/A
software class B or C

22.47 Appliances connected to the water mains N/A


withstand the water pressure expected in normal
use
22.48 Appliances connected to the water mains N/A
constructed to prevent backsiphonage of
nonpotable water
22.49 Appliances connected to the water mains N/A
constructed to prevent backsiphonage of
nonpotable water
22.50 Appliances connected to the water mains N/A
constructed to prevent backsiphonage of
nonpotable water
22.51 Appliances connected to the water mains N/A
constructed to prevent backsiphonage of
nonpotable water
22.52 Appliances connected to the water mains N/A
constructed to prevent backsiphonage of
nonpotable water

23 INTERNAL WIRING P

14 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

23.1 Wireways smooth and free from sharp edges P

Wires protected against contact with burrs, N/A


cooling fins etc.

Wire holes in metal well rounded or provided with P


bushings

Wiring effectively prevented from coming into P


contact with moving parts

23.2 Beads etc. on live wires cannot change their No beads N/A
position, and are not resting on sharp edges or
corners
23.3 Electrical connections and internal conductors No such maintenance part N/A
movable relatively to each other not exposed to
undue stress
23.4 Bare internal wiring sufficiently rigid and fixed No bare internal wiring N/A

23.5 The insulation of internal wiring withstanding the P


electrical stress likely to occur in normal use

No breakdown when a voltage of 2000 V is P


applied for 15 min between the conductor and
metal foil wrapped around the insulation
23.6 Sleeving used as supplementary insulation on No sleeving N/A
internal wiring retained in position by positive
means
23.7 The colour combination green/yellow used only P
for earthing conductors

23.8 Aluminum wires not used for internal wiring N/A

23.9 No lead-tin soldering of stranded conductors No lead-tin soldering used P


where they are subject to contact pressure,

23.10 The insulation and sheath of internal wiring, N/A


incorporated in external hoses for the connection
of an appliance to the water mains, at least
equivalent to that of light polyvinyl chloride
sheathed flexible cord

24 COMPONENTS P

24.1 Components comply with safety requirements in P


relevant IEC standards
Components not tested and found to comply with P
relevant IEC standard for the number of cycles
specified are tested in accordance with 24.1.1 to
24.1.9

15 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Components not tested and found to comply with P


relevant IEC standard, components not marked
or not used in accordance with its marking, tested
under the conditions occurring in the appliance
No devices causing the protective device in the P
fixed wiring to operate in the event of a fault in
the appliance
No thermal cut-outs that can be reset by N/A
soldering
24.2 No switches or automatic controls in flexible N/A
cords
24.3 Switches intended for all-pole disconnection of N/A
stationary appliances are directly connected to
the supply terminals and having a contact
separation in all poles, providing full
disconnection under overvoltage category III
conditions
24.4 Plugs and socket-outlets for extra-low voltage N/A
circuits and heating elements, not
interchangeable with plugs and socket-outlets
listed in IEC 60083 or IEC 60906-1 or with
connectors and appliance inlets complying with
the standard sheets of IEC 60320-1
24.5 Capacitors in auxiliary windings of motors marked N/A
with their rated voltage and capacitance and used
accordingly

24.6 Working voltage of motors connected to the N/A


supply mains and having basic insulation that is
inadequate for the rated voltage of the appliance,
not exceeding 42V.
24.7 Hose-sets for connection of appliances to the N/A
water mains, complying with IEC 61770 and
supplied with the appliance

25 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS P

25.1 Appliance not intended for permanent connection to fixed wiring, means for P
connection to the supply:
- supply cord fitted with a plug N/A
- an appliance inlet having at least the same N/A
degree of protection against moisture as required
for the appliance
- pins for insertion into socket-outlets N/A

- a set of terminals allowing the connection of a P


supply cord
25.2 Appliance not provided with more than one N/A
means of connection to the supply mains

16 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

25.3 Connection of supply conductors for appliance N/A


intended to be permanently connected to fixed
wiring possible after the appliance has been fixed
to its support
25.4 Cable and conduit entries, rated current of N/A
appliance not exceeding 16 A, dimensions
according to table 10

25.5 Method for assemble supply cord with the appliance: N/A

- type X attachment N/A

- type Y attachment N/A

- type Z attachment, if allowed in part 2 N/A

25.6 Plugs fitted with only one flexible cord N/A

25.7 Supply cord not lighter than specified supply cord N/A
in clause 25.7

25.8 Nominal cross-sectional area of supply cords N/A


according to table 11; rated current (A); cross-
sectional area (mm²)

25.9 Supply cord not in contact with sharp points or P


edges

25.10 Green/yellow core for earthing purposes in Class N/A


I appliance

25.11 Conductors of supply cords not consolidated by N/A


lead-tin soldering where they are subject to
contact pressure
25.12 Moulding the cord to part of the enclosure does N/A
not damage the insulation of the supply cord

25.13 Inlet opening so shaped as to prevent damage to N/A


the supply cord

25.14 Supply cords adequately protected against N/A


excessive flexing

25.15 Conductors of the supply cord relieved from P


strain, twisting and abrasion by use of cord
anchorage

The cord cannot be pushed into the appliance to P


such an extent that the cord or internal parts of
the appliance can be damaged

17 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

25.16 Cord anchorages for type X attachments constructed and located so that: P

replacement of the cord is easily possible P

25.17 Adequate cord anchorages for type Y and Z N/A


attachment

25.18 Cord anchorages only accessible with the aid of a P


tool,

25.19 Type X attachment, glands not used as cord N/A


anchorage in portable appliances

25.20 Conductors of the supply cord for type Y and Z N/A


attachment adequately additionally insulated

25.21 Space for supply cord for type X attachment or for P


connection of fixed wiring constructed to permit
checking of conductors with respect to correct
positioning and connection before fitting any
cover, no risk of damage to the conductors when
fitting the cover, no contact with accessible metal
parts if a conductor becomes loose, etc.

25.22 Appliance inlet: N/A


-live parts not accessible during insertion or
removal
-connector can be inserted without difficulty
25.23 Interconnection cords comply with the P
requirements for the supply cord, except as
specified

25.24 Interconnection cords not detachable without the N/A


aid of a tool if compliance with the standard is
impaired when they are disconnected

25.25 Dimensions of pins compatible with the N/A


dimensions of the relevant socket-outlet.
Dimensions of pins and engagement face in
accordance with the relevant plug in IEC 60083

26 TERMINALS FOR EXTERNAL CONDUCTORS P

26.1 Appliances provided with terminals or equally P


effective devices for connection of external
conductors

Terminals only accessible after removal of a P


nondetachable cover

18 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

26.2 Appliances with type X attachment and P


appliances for connection to fixed wiring provided
with terminals in which connections are made by
means of screws, nuts or similar devices, unless
the connections are soldered
Screws and nuts serve only to clamp supply P
conductors, except:

internal conductors, if so arranged that they are P


unlikely to be displaced when fitting the supply
conductors
If soldered connections used, the conductor so N/A
positioned or fixed that reliance is not placed on
soldering alone
Soldering alone used, barriers provided, N/A
clearances and creepage distances satisfactory if
the conductor becomes free at the soldered joint

26.3 Terminals for type X attachment and for P


connection to fixed wiring so constructed that the
conductor is clamped between metal surfaces
with sufficient contact pressure and without
damaging the conductor

Terminals for type X attachment and those for connection to fixed wiring so fixed that P
when tightening or loosening the clamping means:

- the terminal does not loosen P

- internal wiring is not subjected to stress P

- clearances and creepage distances are not P


reduced below the values in 29

26.4 Terminals for type X attachment, except those P


with a specially prepared cord, and those for
connection to fixed wiring, no special preparation
of conductors required, and so constructed or
placed that conductors prevented from slipping
out
26.5 Terminals for type X attachment so located or P
shielded that if a wire of a stranded conductor
escapes, no risk of accidental connection to other
parts that result in a hazard
Stranded conductor test, 8 mm insulation P
removed

19 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

No contact between live parts and accessible N/A


metal parts and, for class II constructions,
between live parts and metal parts separated
from accessible metal parts by supplementary
insulation only

26.6 Terminals for type X attachment and for P


connection to fixed wiring suitable for connection
of conductors with required cross-sectional area
according to table 13; rated current (A); nominal
cross-sectional area (mm²)
Terminals only suitable for a specially prepared P
cord

26.7 Terminals for type X attachment accessible after P


removal of a cover or part of the enclosure

26.8 Terminals for the connection to fixed wiring, P


including the earthing terminal, located close to
each other

26.9 Terminals of the pillar type constructed and P


located as specified

26.10 Terminals with screw clamping and screwless P


terminals not used for flat twin tinsel cords, unless
conductors ends fitted with a device suitable for
screw terminals

Pull test of 5 N to the connection P

26.11 For type Y and Z attachment: soldered, welded, N/A


crimped and similar connections may be used

27 PROVISION FOR EARTHING P

27.1 Accessible metal parts of Class 0I and I Connected to contact of the P


appliances, permanently and reliably connected appliance inlet
to an earthing terminal or contact of the appliance
inlet
Earthing terminals not connected to neutral P
terminal
Class 0, II and III appliance have no provision for N/A
earthing

Safety extra-low voltage circuits not earthed, N/A


unless protective extra-low voltage circuits

27.2 Clamping means adequately secured against P


accidental loosening

20 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Terminals used for the connection of external P


equipotential bonding conductors allow
connection of conductors of 2.5 to 6 mm², and
do not provide earthing continuity between P
different parts of the appliance
Conductors cannot be loosened without the aid of P
a tool

27.3 For detachable parts that are plugged into N/A


another part of the appliance, and having an
earth connection, the earth connection made
before and separated after current-carrying
connections when removing the part
For appliances with supply cord, current-carrying N/A
conductors become taut before earthing
conductor, if the cord slips out of the cord
anchorage
27.4 No risk of corrosion resulting from contact P
between metal of earthing terminal and other
metal
Adequate resistance to corrosion of coated or P
uncoated parts providing earthing continuity,
other than parts of a metal frame or enclosure

Parts of steel providing earthing continuity N/A


provided at the essential areas with an
electroplated coating, thickness at least 5 μm
Adequate protection against rusting of parts of P
coated or uncoated steel, only intended to
provide or transmit contact pressure

In case of aluminum alloys precautions taken to N/A


avoid risk of corrosion

27.5 Low resistance of connection between earthing P


terminal and earthed metal parts

This requirement does not apply to connections P


providing earthing continuity in the protective
extralow voltage circuit, provided that clearances
of basic insulation are based on the rated voltage
of the appliance

Resistance not exceeding 0,1 Ω at the specified 0.015 Ω P


low resistance test

27.6 The printed conductors of printed circuit boards N/A


not used to provide earthing continuity in hand
held appliances

They may be used in other appliances if: N/A

21 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

- at least two tracks are used with independent N/A


soldering points and the appliance complies with
requirements of 27.5 for each circuit

- the material of the printed circuit board complies N/A


with IEC 60249-2-4 or IEC 60249-2-5

28 SCREWS AND CONNECTIONS P

28.1 Fixings, electrical connections and connections P


providing earthing continuity withstand
mechanical stresses
Screws not of soft metal liable to creep, such as P
zinc or aluminum

Diameter of screws of insulating material min. 3 No such screws of insulating N/A


mm material

Screws of insulating material not used for any N/A


electrical connection or connections providing
earthing continuity

Screws used for electrical connections or N/A


connections providing earthing continuity screw
into metal
Screws not of insulating material if their P
replacement by a metal screw can impair
supplementary or reinforced insulation
Type X attachment, screws to be removed for N/A
replacement of supply cord or for user
maintenance, not of insulating material if their
replacement by a metal screw can impair basic
insulation

For screws and nuts; test as specified P

28.2 Electrical connections and connections providing P


earthing continuity constructed so that contact
pressure not transmitted through insulating
material liable to shrink or distort, unless
shrinkage or distortion compensated
This requirement does not apply to electrical N/A
connections in circuits carrying a current not
exceeding 0.5A
28.3 Space-threaded (sheet metal) screws only used P
for electrical connections if they clamp the parts
together

22 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Thread-cutting (self-tapping) screws only used for N/A


electrical connections if they generate a full form
standard machine screw thread

Such screws not used if they are likely to be N/A


operated by the user or installer unless the thread
is formed by a swaging action

Thread-cutting and space-threaded screws may N/A


be used in connections providing earthing
continuity, provided unnecessary to disturb the
connection and at least two screws are used for
each connection

28.4 Screws and nuts that make mechanical P


connection secured against loosening if they also
make electrical connections or connections
providing earthing continuity
Rivets for electrical connections or connections P
providing earthing continuity secured against
loosening if subjected to torsion

29 CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH P


INSULATION
Clearances, creepage distances and solid P
insulation withstand electrical stress
For coatings used on printed circuits boards to N/A
protect the microenvironment (Type A) or to
provide basic insulation (Type B), annex J applies
The microenvironment is pollution degree 1 under N/A
Type A coating
No creepage distance or clearance requirements N/A
under Type B coating
29.1 Clearances not less than the values specified in P
table 16, taking into account the rated impulse
voltage for the overvoltage categories of table 15,
unless

for basic insulation and functional insulation they N/A


comply with the implulse voltage test of clause 14

However, if the construction is affected by wear, P


distortion, movement of the parts or during
assembly, the clearances for rated impulse
voltages of 1500V and above are increased by
0,5 mm and the impulse voltage test is not
applicable

Compliance is checked by inspection and P


measurements as specified

23 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

29.1.1 Clearances of basic insulation withstand the P


overvoltages, taking into account the rated
impulse voltage

Clearance at the terminals of tubular sheathed No tubular sheathed heating N/A


heating elements may be reduced to 1mm if the elements
microenvironment is pollution degree 1
Lacquered conductors of windings considered to N/A
be bare conductors

29.1.2 Clearances of supplementary insulation not less N/A


than those specified for basic insulation in table
16
29.1.3 Clearances of reinforced insulation not less than P
those specified for basic insulation in table 16, but
using the next higher step for rated impulse
voltage
29.1.4 For functional insulation, the values of table 16 N/A
are applicable, unless
the appliance complies with clause 19 with the P
functional insulation short-circuited
Lacquered conductors of windings considered to N/A
be bare conductors
However, clearances at crossover points are not N/A
measured
Clearance between surfaces of PTC heating No PTC heating elements N/A
elements may be reduced to 1mm

29.1.5 Appliances having higher working voltage than N/A


rated voltage, the voltage used for determining
clearances from table 16 is the sum of the rated
impulse voltage and the difference between the
peak value of the working voltage and the peak
value of the rated voltage

If the secondary winding of a step-down N/A


transformer is earthed, or if there is an earthed
screen between the primary and secondary
windings, clearances of basic insulation on the
secondary side not less than those specified in
table 16, but using the next lower
step for rated impulse voltage

Circuits supplied with a voltage lower than rated P


voltage, clearances of functional insulation based
on the working voltage used as the rated voltage
in table 15
29.2 Creepage distances not less than those P
appropriate for the working voltage, taking into
account the material group and the pollution
degree

24 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Pollution degree 2 applies, unless P

precautions taken to protect the insulation; N/A


pollution degree 1
insulation subjected to conductive pollution; N/A
pollution degree 3
Compliance is checked by inspection and P
measurements as specified

29.2.1 Creepage distances of basic insulation not less P


than specified in table 17
For pollution degree 1, creepage distance not N/A
less than the minimum specified for the clearance
in table 16, if the clearance has been checked
according to the test of clause 14
29.2.2 Creepage distances of supplementary insulation No supplementary insulation N/A
at least as specified for basic insulation in table
17
29.2.3 Creepage distances of reinforced insulation at P
least double as specified for basic insulation in
table 17
29.2.4 Creepage distances of functional insulation not P
less than specified in table 18
Creepage distances may be reduced if the P
appliance complies with clause 19 with the
functional insulation short-circuited
29.3 Supplementary and reinforced insulation having P
adequate thickness, or a sufficient number of
layers, to withstand the electrical stresses
Compliance checked by: P

- measurement, in accordance with 29.3.1, or P


- an electric strength test in accordance with N/A
29.3.2, or
- an assessment of the thermal quality of the N/A
material combined with an electric strength test,
in accordance with 29.3.3
29.3.1 Supplementary insulation having a thickness of at N/A
least 1 mm
Reinforced insulation having a thickness of at N/A
least 2 mm

29.3.2 Each layer of material withstand the electric N/A


strength test of 16.3 for supplementary insulation
Supplementary insulation consisting of at least 2 N/A
layers
Reinforced insulation consisting of at least 3 N/A
layers

25 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

The insulation is subjected to the dry heat test Bb N/A


of IEC 60068-2-2, followed by
the electric strength test of 16.3 N/A
If the temperature rise during the tests of Clause N/A
19 does not exceed the value specified in Table
3, the test of IEC 60068-2-2 is not carried out

30 RESISTANCE TO HEAT, FIRE AND TRACKING P

30.1 External parts of non-metallic material, N/A

parts supporting live parts, and P


thermoplastic material providing supplementary N/A
or reinforced insulation,

sufficiently resistant to heat N/A

Ball-pressure test according to IEC 60695-10-2 P

External parts: at 40 °C plus the maximum N/A


temperature rise determined during the test of
clause 11, or at 75 °C, whichever is the higher;
temperature(C)

Parts supporting live parts: at 40°C plus the P


maximum temperature rise determined during the
test of clause 11, or at 125°C, whichever is the
higher; temperature (°C)
Parts of thermoplastic material providing N/A
supplementary or reinforced insulation, 25°C plus
the maximum temperature rise determined during
clause 19, if higher; temperature (°C)

30.2 Relevant parts of non-metallic material P


adequately resistant to ignition and spread of fire
30.2.1 Glow-wire test of IEC 60695-2-11 at 550 °C, P
unless
the material is classified at least HB40 according N/A
to IEC 60695-11-10

Parts for which the glow-wire test cannot be N/A


carried out meet the requirements in ISO9772 for
category HBF material

30.2.2 Appliances operated while attended, parts of insulating material supporting N/A
currentcarrying connections and parts within a distance of 3mm subjected to the
glow-wire test of IEC 60695-2-11 at a temperature of:

26 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

-750°C, for connections carrying a current N/A


exceeding 0,5A during normal operation

-650°C, for other connections N/A

Test not applicable to conditions as specified N/A

30.2.3 Appliances operated while unattended, tested as P


specified in 30.2.3.1 and 30.2.3.2
30.2.3.1 Parts of insulating material supporting P
connections carrying a current exceeding 0.2A
during normal operation, and

parts of insulating material within a distance of P


3mm,

having a glow-wire flammability index of at least P


850°C according to IEC 60695-2-12

30.2.3.2 Parts of insulating material supporting P


currentcarrying connections, and

parts of insulating material within a distance of P


3mm,

subjected to glow-wire test of IEC 60695-2-11 P

Test not carried out on material having a glow- P


wire ignition temperature according to IEC 60695-
2-13 as specified

Glow-wire test of IEC 60695-2-11, the temperature being: P

-750°C, for connections carrying a current P


exceeding 0,2A during normal operation

-650°C, for other connections P

Parts that during the test produce a flame P


persisting longer than 2 s, tested as specified

If a flame persists longer than 2 s during the test, P


parts above the connection, as specified,
subjected to the needle-flame test of annex E,
unless
the material is classified as V-0 or V-1 according N/A
to IEC 60695-11-10

30.2.4 Base material of printed circuit boards subjected N/A


to needle-flame test of annex E

27 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

31 RESISTANCE TO RUSTING P
This claus of Part 1 is not applicable for outdoor P
enclosure

32 RADIATION, TOXICITY AND SIMILAR HAZARDS --


Appliance does not emit harmful radiation Complied p

Appliance does not present a toxic or similar Complied p


hazard

Annex: AA
AA.1 RUNNING OVERLOAD TESTS FOR MOTOR-COMPRESSORS CLASSIFIED AS --
TESTED WITH ANNEX AA
Before testing in accordance with this annex is p
started it shall be verified that the motor-
compressor is in working order by applying the
test of 16.3 and then by operating it in a
substitute refrigeration circuit at rated voltage and
under the appropriate running overload
conditions specified in table AA.1 for a period of
not less than 2 h

Table AA.1 – Substitute refrigeration circuit conditions for operating under running overload conditions
Application Evaporation Condensation Motor-compressor Return gas
category temperature temperature Ambient temperature Temperature

Low back pressure -15 +65 +43 +43

Medium back 0 +65 +43 +25


pressure

High back pressure +15 +65 +43 +25

AA.2 The motor-compressor including its protection p


system and control system if any is connected to
the substitute refrigeration circuit of figure AA.1
and operated under the appropriate conditions
given in table AA.1

28 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

AA.3 Immediately after the tests of clause AA.2 the p


following tests are conducted to cause the motor-
compressor protection system to operate or to
reach steady conditions with the motor-
compressor in the stalled or running condition.

13.3 TABLE: electric strength measurements at operating temperature P


test voltage applied between: test voltage (V) breakdown
L/N – accessible metal part 1000 No
16.2 TABLE: leakage current measurements P
At 1.06 times rated voltage (V) ...............................: 254.4V —
leakage current I between: inner fan motor (Welling) I (mA) Limit I (mA)
Live part – accessible metal part 0.13 3.5

16.3 TABLE: electric strength measurements P

test voltage applied between: test voltage (V) breakdown

Live part – accessible metal part 1 250 NO

29.1 TABLE: Clearances P


Overvoltage category ..................... ............... ... : II -
Type of insulation:
Rated
impulse Basic Supplementary Reinforced Functional Verdict /
Min. cl (mm)
voltage (mm) (mm) (mm) (mm) Remark
(V):
330 0,5* - - - - N/A
500 0,5* - - - - N/A
800 0,5* - - - - N/A
1 500 0,5 */** - - - - N/A
2 500 1,5** >2,0 >3,5 - - P
4 000 3,0** - - - - N/A
6 000 5,5** - - - - N/A
8 000 8,0** - - - - N/A
10 000 11,0** - - - - N/A
Supplementary information:
*) The value is increased to 0,8mm for pollution degree 3
*) If the construction is affected by wear, distortion, movement of the parts or during assembly, the
value is increased by 0,5mm (A1:2004)

29.2 TABLE: Creepage distances, basic, supplementary and reinforced insulation P

29 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Creepage distance
Working voltage
(mm)
(V)
Pollution degree
Type of
1 2 3
insulation
Material group Material group
I II IIIa/IIIb I II IIIa/IIIb* B** S** R** Verdict
 50 0,2 0,6 0,9 1,2 1,5 1,7 1,9  - - N/A
 50 0,2 0,6 0,9 1,2 1,5 1,7 1,9 - - N/A
 50 0,4 1,2 1,8 2,4 3,0 3,4 3,8 - -  N/A
125 0,3 0,8 1,1 1,5 1,9 2,1 2,4  - - N/A
125 0,3 0,8 1,1 1,5 1,9 2,1 2,4 - - N/A
125 0,6 1,6 2,2 3,0 3,8 4,2 4,8 - -  N/A
250 0,6 1,3 1,8 2,5 3,2 3,6 4,0 >1,8  - - P
250 0,6 1,3 1,8 2,5 3,2 3,6 4,0 >3,6 - - P
250 1,2 2,6 3,6 5,0 6,4 7,2 8,0 - - N/A
400 1,0 2,0 2,8 4,0 5,0 5,6 6,3 >2.8 - - P
400 1,0 2,0 2,8 4,0 5,0 5,6 6,3 >4.0 - P
400 2,0 4,0 5,6 8,0 10,0 11,2 12,6 - - N/A
400 1,0 2,0 2,8 4,0 5,0 5,6 6,3 - - N/A
400 1,0 2,0 2,8 4,0 5,0 5,6 6,3 -  - N/A
400 2,0 4,0 5,6 8,0 10,0 11,2 12,6 - - N/A
500 1,3 2,5 3,6 5,0 6,3 7,1 8,0  - - N/A
500 1,3 2,5 3,6 5,0 6,3 7,1 8,0 -  - N/A
500 2,6 5,0 7,2 10,0 12,6 14,2 16,0 - - N/A
>630 and ≤800 1,8 3,2 4,5 6,3 8,0 9,0 10,0  - - N/A
>630 and ≤800 1,8 3,2 4,5 6,3 8,0 9,0 10,0 -  - N/A
>630 and ≤800 3,6 6,4 9,0 12,6 16,0 18,0 20,0 - - N/A
>800 and ≤1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5  - - N/A
>800 and ≤1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5 - - N/A
>800 and ≤1000 4,8 8,0 11,2 16,0 20,0 22,0 25,0 - - N/A
>1000 and≤1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0 - - N/A
>1000 and≤1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0 - - N/A
>1000 and≤1250 6,4 10,0 14,2 20,0 25,0 28,0 32,0 - - N/A
>1250 and≤1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0 - - N/A
>1250 and≤1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0 - - N/A
>1250 and≤1600 8,4 12,6 18,0 25,0 32,0 36,0 40,0 - - N/A
Supplementary information:
*) Material group IIIb is allowed if the working voltage does not exceed 50 V
**) B = Basic insulation, S = Supplementary insulation, R = Reinforced insulation

29.2 TABLE: Creepage distances, basic, supplementary and reinforced insulation P


Creepage distance
Working voltage (V) (mm)
Pollution degree
1 2 3

30 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Material group Material group Verdict /


I II IIIa/IIIb I II IIIa/IIIb* Remark
50 0,2 0,6 0,8 1,1 1,4 1,6 1,8 N/A
125 0,3 0,7 1,0 1,4 1,8 2,0 2,2 N/A
250 0,42 1,0 1,4 2,0 2,5 2,8 3,2 P
400 0,75 1,6 2,2 3,2 4,0 4,5 5,0 P
500 1,0 2,0 2,8 4,0 5,0 5,6 6,3 N/A
 >630 and ≤800 1,8 3,2 4,5 6,3 8,0 9,0 10,0 N/A
>800 and ≤1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5 N/A
>1000 and ≤1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0 N/A
>1250 and ≤1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0 N/A
>1600 and ≤2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0 N/A
>2000 and ≤2500 7,5 10,0 14,0 20,0 25,0 28,0 32,0 N/A
>2500 and ≤3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0 N/A
>3200 and ≤4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0 N/A
>4000 and ≤5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0 N/A
>5000 and ≤6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0 N/A
>6300 and ≤8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0 N/A
>8000 and ≤10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0 N/A
>10000 and ≤12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0 N/A
Supplementary information:
*) Material group IIIb is allowed if the working voltage does not exceed 50 V

IEC 60335-2-34: 2021


Clause Requirement + Test Result - Remark Verdict
AA TABLE: running and overload tests P
Starting control device……………………………: QL2-6.5 B3 
Protection system (1), if present………………..: DRB33S61A2 
Protection system (2)……………………………..: -- 
Start capacitor……………………………………...: 65μF 
Run capacitor………………………………………: -- 
Cooling; (static); (fan-m3/h); (oil)………………..: Fan 
Resistance of the main winding R1 7.27 (Ω) under 24.9°C
Resistance of the secondary winding R2 --

AA.1 TABLE: running test P


Test number 1
1,06 rated voltage Application
category
VLBP LBP MB HBP VHBP
P

31 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Evaporation temperature (°C) -- -15 -- -- -


-
Condensation temperature (°C) -- 65 -- -- -
-
Return gas temperature (°C) -- 43 -- -- -
-
Room temperature (°C) 43 
Protection system operates (Yes/No) No 
Optional (F = fan / S = static) F 
Test number 2
0,94 rated voltage Application
category
VLBP LBP MB HBP VHBP
P
Evaporation temperature (°C) -- -15 -- -- -
-
Condensation temperature (°C) -- 65 -- -- -
-
Return gas temperature (°C) -- 43 -- -- -
-
Room temperature (°C) 43 
Protection system operates (Yes/No) No 
Optional (F = fan / S = static) F 
TABLE: running test --
Ambient, t1 (°C)……………………………………………………: -- 
Ambient, t2 (°C)……………………………………………………: -- 
Temperature rise of winding: R1 (Ω) R2 (Ω) T Max. T Insulation
(°C) (°C) class

Supplementary information:

AA.2 TABLE: overload test P


Test of 16.3 P 
Test under the conditions specified in Table AA.1 for a period of not less than 2 h
Rated voltage Application category
VLBP LBP MBP HBP VHBP
Evaporation temperature (°C) -- -15 -- -- --
Condensation temperature (°C) -- 65 -- -- --
Return gas temperature (°C) -- 43 -- -- --

32 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Maximum value of the current average over any 5 min 0,35 


period (A)
Room temperature (°C) 43 
Protection system operates (Yes/No) No 
Optional (F = fan / S = static) F 
TABLE: overload test N/A
Ambient, t1 (°C)……………………………………………………: 
Ambient, t2 (°C)…………………………………………………...: 
Temperature of winding: R1 (Ω) R2 (Ω) Δ T (K) T (°C) Max. T
(°C)

Supplementary information:

AA.3 TABLE: overload test P


Test under the conditions of maximum load given in Table AA.1 until steady conditions are reached
Test number 1
1,06 rated voltage Application category
VLBP LBP MBP HBP VHBP
Evaporation temperature (°C) -- -15 -- -- --
Condensation temperature (°C) -- 65 -- -- --
Return gas temperature (°C) -- 43 -- -- --
Room temperature (°C) 43 
Protection system operates (Yes/No) No 
Optional (F = fan / S = static) F 
Test number 2
0,85 rated voltage Application category
VLBP LBP MBP HBP VHBP
Evaporation temperature (°C) -- -15 -- -- --
Condensation temperature (°C) -- 65 -- -- --
Return gas temperature (°C) -- 43 -- -- --
Room temperature (°C) 43 
Protection system operates (Yes/No) No 
Optional (F = fan / S = static) F 
TABLE: overload test N/A
Ambient, t1 (°C)……………………………………………………: 

33 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Ambient, t2 (°C)…………………………………………………...: 
Temperature of winding: R1 (Ω) R2 (Ω) Δ T (K) T (°C) Max. T
(°C)

Part Measured (°C) Allowed (°C)


Motor-compressor control system (K)
Motor-compressor protection system (K)
Other parts:

Motor-compressor protection system operates (Yes/No) No


Housing temperature (°C) 64,7 ≤
150 °C
Further test until steady conditions are reached
Rated voltage Application category
VLBP LBP MBP HBP VHBP

Evaporation temperature (°C) -- -15 -- -- --


Condensation temperature -- 65 -- -- --
(°C)
Return gas temperature (°C) -- 43 -- -- --
Room temperature (°C) 43 
Protection system operates (Yes/No) Yes 
Optional (F = fan / S = static) F 
TABLE: overload test P
Ambient, t1 (°C)……………………………………………………: 22,0 
Ambient, t2 (°C)…………………………………………………...: 43 
Temperature of winding: R1 (Ω) R2 (Ω) ΔT T (°C) Max. T
(K) (°C)
Main winding 7.27 (under 10.3 76.7 119.7 150
24.9℃)
Secondary winding -- -- -- -- 150

Protective device operates (Yes/No) No 


Motor-compressor stalls and steady conditions are reached Yes 
In neither of these conditions shall the motor-compressor No 
winding temperature exceed 160 °C for motor-compressors
with synthetic insulation and 150 °C for motor-compressors
with cellulosic insulation

34 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Supplementary information:

IEC 60335-2-34: 2021


Requirement + Test Result - Remark Verdict
TABLE: running and overload tests P
Starting control device……………………………: QL2-6.5 B3 
Protection system (1), if present………………..: DRB33S61A2 
Protection system (2)……………………………..: -- 
Start capacitor……………………………………...: 65μF 
Run capacitor………………………………………: -- 
Cooling; (static); (fan-m3/h); (oil)………………..: F 
Resistance of the main winding R1 7.27 (Ω) under 24.9°C
Resistance of the secondary winding R2 --

AA.1 TABLE: running test P


Test number 1
1,06 rated voltage Application category
VLBP LBP MBP HBP VHBP
Evaporation temperature (°C) -- -- 0 -- --
Condensation temperature (°C) -- -- 65 -- --
Return gas temperature (°C) -- -- 25 -- --
Room temperature (°C) 43 
Protection system operates (Yes/No) No 
Optional (F = fan / S = static) F 
Test number 2
0,94 rated voltage Application category
VLBP LBP MBP HBP VHBP
Evaporation temperature (°C) -- -- 0 -- --
Condensation temperature (°C) -- -- 65 -- --
Return gas temperature (°C) -- -- 25 -- --
Room temperature (°C) 43 
Protection system operates (Yes/No) No 
Optional (F = fan / S = static) F 
TABLE: running test --

35 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Ambient, t1 43 --
(°C)……………………………………………………:
Ambient, t2 43 
(°C)…………………………………………………...:
Temperature rise of winding: R1 (Ω) R2 (Ω) T Max. T Insulation
(°C) (°C) class
- -- -- -- -- --
-
- -- -- -- -- --
-
Supplementary information:

AA.2 TABLE: overload test P


Test of 16.3 P 
Test under the conditions specified in Table AA.1 for a period of not less than 2 h
Rated voltage Application category
VLBP LBP MBP HBP VHBP
Evaporation temperature (°C) -- -- 0 -- --
Condensation temperature (°C) -- -- 65 -- --
Return gas temperature (°C) -- -- 25 -- --
Maximum value of the current average over any 5 min 2.38 
period (A)
Room temperature (°C) 43 
Protection system operates (Yes/No) No 
Optional (F = fan / S = static) F 
TABLE: overload test N/A
Ambient, t1 (°C)……………………………………………………: 
Ambient, t2 (°C)…………………………………………………...: 
Temperature of winding: R1 (Ω) R2 (Ω) Δ T (K) T (°C) Max. T
(°C)

Supplementary information:

AA.3 TABLE: overload test P


Test under the conditions of maximum load given in Table AA.1 until steady conditions are reached
Test number 1
1,06 rated voltage Application category
VLBP LBP MBP HBP VHBP
36 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Evaporation temperature (°C) -- -- 0 -- --


Condensation temperature (°C) -- -- 65 -- --
Return gas temperature (°C) -- -- 25 -- --
Room temperature (°C) 43 
Protection system operates (Yes/No) No 
Optional (F = fan / S = static) F 
Test number 2
0,85 rated voltage Application category
VLBP LBP MBP HBP VHBP
Evaporation temperature (°C) -- -- 0 -- --
Condensation temperature (°C) -- -- 65 -- --
Return gas temperature (°C) -- -- 25 -- --
Room temperature (°C) 43 
Protection system operates (Yes/No) No 
Optional (F = fan / S = static) F 
TABLE: overload test N/A
Ambient, t1 (°C)……………………………………………………: 
Ambient, t2 (°C)…………………………………………………...: 
Temperature of winding: R1 (Ω) R2 (Ω) Δ T (K) T (°C) Max. T
(°C)

Part Measured (°C) Allowed (°C)


Motor-compressor control system (K)
Motor-compressor protection system (K)
Other parts:

Motor-compressor protection system operates (Yes/No) No


Housing temperature (°C) 72.5 ≤
150 °C
Further test until steady conditions are reached
Rated voltage Application category
VLBP LBP MBP HBP VHBP

Evaporation temperature -- -- 0 -- --
(°C)
Condensation -- -- 65 -- --
37 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

temperature (°C)
Return gas temperature -- -- 25 -- --
(°C)
Room temperature (°C) 43 
Protection system operates (Yes/No) Yes 
Optional (F = fan / S = static) F 
TABLE: overload test P
Ambient, t1 (°C)……………………………………………………: 24.9 
Ambient, t2 (°C)…………………………………………………...: 43 
Temperature of winding: R1 (Ω) R2 (Ω) Δ T (K) T (°C) Max. T
(°C)
Main winding 7.27 (under 9.72 66 109.1 150
24.9℃)
Secondary winding -- -- -- -- 150

Protective device operates (Yes/No) Yes 


Motor-compressor stalls and steady conditions are reached No 
In neither of these conditions shall the motor-compressor Yes 
winding temperature exceed 160 °C for motor-compressors
with synthetic insulation and 150 °C for motor-compressors
with cellulosic insulation
Supplementary information:

AA.1 TABLE: running test P


Test number 1
1,06 rated voltage Application category
VLBP LBP MBP HBP VHBP
Evaporation temperature (°C) -- -- -- 15 --
Condensation temperature (°C) -- -- -- 65 --
Return gas temperature (°C) -- -- -- 25 --
Room temperature (°C) 43 
Protection system operates (Yes/No) No 
Optional (F = fan / S = static) F 
Test number 2
0,94 rated voltage Application category
VLBP LBP MBP HBP VHBP
38 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Evaporation temperature (°C) -- -- -- 15 --


Condensation temperature (°C) -- -- -- 65 --
Return gas temperature (°C) -- -- -- 25 --
Room temperature (°C) 43 
Protection system operates (Yes/No) No 
Optional (F = fan / S = static) F 
TABLE: running test --
Ambient, t1 43 --
(°C)……………………………………………………:
Ambient, t2 43 
(°C)…………………………………………………...:
Temperature rise of winding: R1 (Ω) R2 (Ω) T Max. T Insulation class
(°C) (°C)
- -- -- -- -- --
-
- -- -- -- -- --
-
Supplementary information:

AA.2 TABLE: overload test P


Test of 16.3 P 
Test under the conditions specified in Table AA.1 for a period of not less than 2 h
Rated voltage Application category
VLBP LBP MBP HBP VHBP
Evaporation temperature (°C) -- -- -- 15 --
Condensation temperature (°C) -- -- -- 65 --
Return gas temperature (°C) -- -- -- 25 --
Maximum value of the current average over any 5 min 2.38 
period (A)
Room temperature (°C) 43 
Protection system operates (Yes/No) No 
Optional (F = fan / S = static) F 
TABLE: overload test N/A
Ambient, t1 (°C)……………………………………………………: 
Ambient, t2 (°C)…………………………………………………...: 
Temperature of winding: R1 (Ω) R2 (Ω) Δ T (K) T (°C) Max. T
(°C)

39 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Supplementary information:

AA.3 TABLE: overload test P


Test under the conditions of maximum load given in Table AA.1 until steady conditions are reached
Test number 1
1,06 rated voltage Application category
VLBP LBP MBP HBP VHBP
Evaporation temperature (°C) -- -- -- 15 --
Condensation temperature (°C) -- -- -- 65 --
Return gas temperature (°C) -- -- -- 25 --
Room temperature (°C) 43 
Protection system operates (Yes/No) No 
Optional (F = fan / S = static) F 
Test number 2
0,85 rated voltage Application category
VLBP LBP MBP HBP VHBP
Evaporation temperature (°C) -- -- -- 15 --
Condensation temperature (°C) -- -- -- 65 --
Return gas temperature (°C) -- -- -- 25 --
Room temperature (°C) 43 
Protection system operates (Yes/No) No 
Optional (F = fan / S = static) F 
TABLE: overload test N/A
Ambient, t1 (°C)……………………………………………………: 
Ambient, t2 (°C)…………………………………………………...: 
Temperature of winding: R1 (Ω) R2 (Ω) Δ T (K) T (°C) Max. T
(°C)

Part Measured (°C) Allowed (°C)


Motor-compressor control system (K)
Motor-compressor protection system (K)
Other parts:

Motor-compressor protection system operates (Yes/No) No

40 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Housing temperature (°C) 78.2 ≤


150 °C

Evaporation temperature -- -- -- 15 --
(°C)
Condensation -- -- -- 65 --
temperature (°C)
Return gas temperature -- -- -- 25 --
(°C)
Room temperature (°C) 43 
Protection system operates (Yes/No) Yes 
Optional (F = fan / S = static) F 
TABLE: overload test P
Ambient, t1 (°C)……………………………………………………: 24.9 
Ambient, t2 (°C)…………………………………………………...: 43 
Temperature of winding: R1 (Ω) R2 (Ω) Δ T (K) T (°C) Max. T
(°C)
Main winding 7.27 (under 9.63 63 106.0 150
24.9℃)
Secondary winding -- -- -- -- 150

Protective device operates (Yes/No) Yes 


Motor-compressor stalls and steady conditions are reached No 
In neither of these conditions shall the motor-compressor Yes 
winding temperature exceed 160 °C for motor-compressors
with synthetic insulation and 150 °C for motor-compressors
with cellulosic insulation
Supplementary information: NA

Photos of Main Parts for Reference:


SN PART NAME Model TDS PHOTOS

Rated working
Voltage: 220-
Refrigeration
1 PJL-100 240V~50Hz
Unit
Cooling
Capacity:1100W

41 / 42
CE TEST REPORT FOR REFRIGERATION UNIT
SUPPLIER: Huayi Compressor (Jingzhou) Co., Ltd
IEC 60 335-1: 2020/ IEC 60 335-2-34: 2021/ IEC 60 335-2-89: 2019
Safety of household and similar electrical appliances
Clause Requirement - Test Result - Remark Verdict

Rated working
Voltage: 220-
240V~50Hz
Cooling
Capacity:1100W
2 Compressor E80NL
COP:2.6
Motor
Start/Running
Mode:CSIR
Refrigerant:R290
Rated working
Voltage: 220-
240V~50Hz :
220-240V~50Hz
Running Mode:
3 Condenser Fan YZF20-40 S1
Power Input:40W
Rated Motor
Speed:1300r/min
Electric Isolation
Grade:E

Conclusion:
Place and date of inspection at Huayi Compressor (Jingzhou) Co., Ltd located in Hubei, China and the
sample test performed by manufacturer. Samples are tested in an accredited laboratory of the manufacturer
and concluded that the goods are in conformity with standard no. EN 60335-1, EN 60335-2-34,EN 60335-
2-89. Furthermore, we confirm that the test report is acceptable and the laboratories are qualified.

Quality manager: Xu Jinshi 2025.04.12

42 / 42