EN ISO 13934-2
Date: 2014
Determination of maximum force using the grab method
Test Details
Report Number: SAMPLE-I Print Date: 4/30/2025
Specimens: 3 Jaw Pressure: 100
Required Directions: Both Load Cell: 5000 N
Test Time: 4:04 PM Load Cell SN: 1169572
Test Date: 4/30/2025 Version: 11.0.3.0
Jaw Scheme: T27 Firmware: v1.00p39
Jaw Separation: 100.00 mm Titan SN: 1710/05/22/1236
Force Control Gain: 25 Tested by: Administrator
Procedure Settings
Break Detection: 20 %
Pull To Load Cell Maximum
Speed: 50.00 mm/min
Warp Results
Specimen Maximum Force (N) Elongation at Max. Force Observations
(%)
1 589.79 36.71 -
2 592.84 36.50 -
3 603.64 36.17 -
Mean 595.42 36.46
Weft Results
Specimen Maximum Force (N) Elongation at Max. Force Observations
(%)
1 876.95 79.46 -
2 884.26 79.13 -
3 888.18 79.75 -
Mean 883.13 79.45
Page 1
Warp Graph
Weft Graph
Page 2