Omega Catalogue
Omega Catalogue
GRID-TIE OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage                       120 VDC / 400 VDC   240 VDC / 450 VDC              360 VDC / 450 VDC             360 VDC / 450 VDC     60 VDC / 450 VDC
Start-up Voltage / Initial Feeding Voltage                     130VDC / 150 VDC   130VDC / 150 VDC                130VDC / 150 VDC             130VDC / 150 VDC      130VDC / 150 VDC
MPP Voltage Range                                             120 VDC ~ 380 VDC   90 VDC ~ 430 VDC               120 VDC ~ 430 VDC            120 VDC ~ 430 VDC      120 VDC ~ 430 VDC
Number of MPP Trackers / Maximum Input Current                     1 / 18 A            1 / 18 A                        1 / 18A                      1 / 18A                1 / 23A
GRID OUTPUT (AC)
Nominal Output Voltage                                                                                            220/230/240 VAC
Output Voltage Range                                                                                184 - 264.5 VAC or 195.5 - 253 VAC (Selectable)
Nominal Output Current                                                 6.5A             8.7A                             13A                             13A                21.7A
Power Factor                                                                                                            > 0.99
EFFICIENCY
                                                                                                                         95%
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage / Auto Restart Voltage                                                                     120 - 140 VAC / 180 VAC
Acceptable Input Voltage Range                                                                              90 - 280 VAC or 170 - 280 VAC
Frequency Range                                                                                              50 Hz/60 Hz (Auto sensing)
Maximum AC Input Current                                               30 A             30 A                             40 A                            40 A                40 A
PV INPUT (DC)
Maximum DC Voltage                                                 400 VDC            450 VDC                         450 VDC                      450 VDC                450 VDC
MPP Voltage Range                                             120 VDC ~ 380 VDC   90 VDC ~ 430 VDC               120 VDC ~ 430 VDC            120 VDC ~ 430 VDC      120 VDC ~ 430 VDC
Number of MPP Trackers / Maximum Input Current                      1 / 18 A           1 / 18 A                        1 / 18 A                     1 / 18 A               1 / 23A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage                                                                                             220/230/240 VAC
Output Waveform                                                                                                     Pure sine wave
                                                                       93%              93%                              93%                             93%                93%
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage                       120 VDC / 400 VDC   240 VDC / 450 VDC              360 VDC / 450 VDC            360 VDC / 450 VDC       360 VDC / 450 VDC
Start-up Voltage / Initial Feeding Voltage                     130VDC / 150 VDC   130VDC / 150 VDC                130VDC / 150 VDC             130VDC / 150 VDC       120VDC / 150 VDC
MPP Voltage Range                                             120 VDC ~ 380 VDC   90 VDC ~ 430 VDC               120 VDC ~ 430 VDC            120 VDC ~ 430 VDC      120 VDC ~ 430 VDC
Number of MPP Trackers / Maximum Input Current                     1 / 18 A            1 / 18 A                        1 / 18A                      1 / 18A                1 / 23A
GRID OUTPUT (AC)
Nominal Output Voltage                                                                                            220/230/240 VAC
Output Voltage Range                                                                                184 - 264.5 VAC or 195.5 - 253 VAC (Selectable)
Nominal Output Current                                                 6.5A             8.7A                             13A                             13A                21.7A
AC INPUT
AC Start-up Voltage / Auto Restart Voltage                                                                     120 - 140 VAC / 180 VAC
Acceptable Input Voltage Range                                                                              90 - 280 VAC or 170 - 280 VAC
Maximum AC Input Current                                               30 A             30 A                             40 A                            40 A               40 A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage                                                                                             220/230/240 VAC
                                                                       93%              93%                              93%                             93%                93%
BATTERY & CHARGER
Nominal DC Voltage                                                    48 VDC           48 VDC                          24 VDC                          48 VDC             48 VDC
Maximum Solar Charging Current                                          30A             60 A                            60 A                            60 A               100 A
Maximum AC Charging Current                                             40A             60 A                            60 A                            60 A               100 A
Maximum Charging Current                                                40A             60 A                            60 A                            60 A               100 A
GENERAL
PHYSICAL
Dimension, D x W x H (mm)                                       100 x 300 x 440    120 x 295 x 468                 120 x 295 x 468               120 x 295 x 468       120 x 295 x 468
Net Weight (kgs)                                                       8                  11                              11                            11                    12
INTERACE
Parallel Function                                                      N/A           Yes, 9 units                    Yes, 9 units                     Yes, 9 units       Yes, 9 units
Communication Port                                                                                            USB or RS-232/Dry Contact
ENVIRONMENT
Humidity                                                                                                     0 ~ 90% RH (No condensing)
Operating Temperature                                                                                               -10°C to 50°C
Product specifications are subject to change without further notice
INF
On-grid Inverter with Energy Storage Selection
  GRID-TIE OPERATION
  PV INPUT (DC)
  Nominal DC Voltage / Maximum DC Voltage                             360 VDC / 500 VDC                                                  720 VDC / 900 VDC
  Start-up Voltage / Initial Feeding Voltage                          116 VDC / 150 VDC                           225 VDC / 250 VDC                            320 VDC / 350 VDC
  MPP Voltage Range                                                   250 VDC ~ 450 VDC                           250 VDC ~ 850 VDC                            400 VDC ~ 800 VDC
  Number of MPP Trackers / Maximum Input Current                          1 / 1 x 18A                                 2 / 2 x 10A                                  2 / 2 x 18.6A
  GRID OUTPUT (AC)
  Nominal Output Voltage                                                                    208/220/230/240 VAC                                            230 VAC (P-N) / 400 VAC (P-P)
  Output Voltage Range                                                                         184 - 265 VAC*                                                184 - 265 VAC* per phase
  Nominal Output Current                                                       13A                                         21A                                    14.5A per phase
  Power Factor                                                                                                            > 0.99
  EFFICIENCY
  Maximum Conversion Efficiency (DC/AC)                                                                                    96%
  European Efficiency@ Vnominal                                                                                            95%
  OFF-GRID OPERATION
  AC INPUT
                                                                                                                                                            120 - 140 VAC per phase /
  AC Start-up Voltage / Auto Restart Voltage                                               120 - 140 VAC / 180 VAC
                                                                                                                                                               180 VAC per phase
  Acceptable Input Voltage Range                                                                170 -280 VAC                                                 170 -280 VAC per phase
  Maximum AC Input Current                                                    30 A                                                               40 A
  PV INPUT (DC)
  Maximum DC Voltage                                                       500 VDC                                                           900 VDC
  MPP Voltage Range                                                   250 VDC ~ 850 VDC                           250 VDC ~ 850 VDC                            400 VDC ~ 800 VDC
  Number of MPP Trackers / Maximum Input Current                          1 / 1 x 18A                                 2 / 2 x 10A                                  2 / 2 x 18.6A
  BATTERY MODE OUTPUT (AC)
  Nominal Output Voltage                                                                   202/208/220/230/240 VAC                                        230 VAC (P-N) / 400 VAC (P-P)
  Output Waveform                                                                                                     Pure sine wave
  Efficiency (DC to AC)                                                                              93%                                                               91%
  HYBRID OPERATION
  PV INPUT (DC)
  Nominal DC Voltage / Maximum DC Voltage                             360 VDC / 500 VDC                                                  720 VDC / 900 VDC
  Start-up Voltage / Initial Feeding Voltage                          116 VDC / 150 VDC                            225 VDC / 250 VDC                           320 VDC / 350 VDC
  MPP Voltage Range                                                   250 VDC ~ 450 VDC                            250 VDC ~ 850 VDC                           400 VDC ~ 800 VDC
  Number of MPP Trackers / Maximum Input Current                          1 / 1 x 18A                                  2 / 2 x 10A                                 2 / 2 x 18.6A
  GENERAL
  PHYSICAL
  Dimension, D X W X H (mm)                                              107 x 438 x 480                             204.2 x 460 x 600                           167.2 x 500 x 622
  Net Weight (kgs)                                                             15.5                                         29                                           45
  INTERACE
  Communication Port                                                      RS-232/USB                                               RS-232/USB and CAN Interface
  Intelligent Slot                                                                                Optional SNMP, Modbus and AS-400 cards available
  ENVIRONMENT
  Humidity                                                                                                     0 ~ 90% RH (No condensing)
  Operating Temperature                                                     0 to 40°C                                                       -10 to 55°C
  Altitude                                                                                                             0 ~ 1000 m**
*These figures may vary depending on different AC voltage and country requirements.                                                                                         VDE-AR-N 4105
                                                                                                                                                                            VDE 0126-1-1
** Power derating 1% every 100 m when altitude is over 1000m
Product specifications are subject to change without further notice                                                                                                AS4777, AS/NZS3100, NRS-097-2-1
                                                                                                                                                                   (only for InfiniSolar Plus 3KW)
INF-VII WP
Feed-in Grid inverter with Energy Storage at Good Price/Performance
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage / Auto Restart Voltage                                                           120 - 140 VAC / 180 VAC
Acceptable Input Voltage Range                                                                    90 - 280 VAC or 170 - 280 VAC
Frequency Range                                                                                    50 Hz/60 Hz (Auto sensing)
Maximum AC Input Current                                                    20 A                               30 A                                40 A
PV INPUT (DC)
Maximum DC Voltage                                                         400 VDC                          450 VDC                              500 VDC
MPP Voltage Range                                                     120 VDC ~ 400 VDC                120 VDC ~ 400 VDC                    120 VDC ~ 450 VDC
Number of MPP Trackers / Maximum Input Current                              1 / 10A                          1 / 18A                              1 / 27A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage                                                                                   220/230/240 VAC
Output Waveform                                                                                           Pure sine wave
                                                                            92%                                92%                                93%
HYBRID OPERATION
PV INPUT (DC)
Maximum DC Voltage                                                        400 VDC                            450 VDC                            500 VDC
Start-up Voltage / Initial Feeding Voltage                                                              120 VDC / 150 VDC
MPP Voltage Range                                                     120 VDC ~ 400 VDC                120 VDC ~ 400 VDC                    120 VDC ~ 450 VDC
Number of MPP Trackers / Maximum Input Current                              1 / 10A                           1 / 18A                             1 / 27A
GRID OUTPUT (AC)
Nominal Output Voltage                                                                                  220/230/240 VAC
Output Voltage Range                                                                      184 - 264.5 VAC or 195.5 - 253 VAC (Selectable)
Nominal Output Current                                                      8.7A                               13A                                21.7A
AC INPUT
AC Start-up Voltage / Auto Restart Voltage                                                           120 - 140 VAC / 180 VAC
Acceptable Input Voltage Range                                                                    90 - 280 VAC or 170 - 280 VAC
Maximum AC Input Current                                                    20 A                               30 A                               40 A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage                                                                                   220/230/240 VAC
                                                                            92%                                92%                                93%
BATTERY & CHARGER
Nominal DC Voltage                                                                                           48 VDC
Maximum Charging Current                                                    40 A                              60 A                                80 A
GENERAL
PHYSICAL
Dimension, D x W x H (mm)                                                                               200 x 350 x 592.7
Net Weight (kgs)                                                                                               20
INTERACE
Parallel Function                                                                                         Yes, 9 units
Communication Port                                                                             USB or RS-232 / Dry Contact/RS485
ENVIRONMENT
Humidity                                                                                           0 ~ 95% RH (No condensing)
Operating Temperature                                                                                     -25°C to 50°C
Product specifications are subject to change without further notice
INF-VII WP
Feed-in Grid inverter with Energy Storage at Good Price/Performance
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage / Auto Restart Voltage                                                           120 - 140 VAC / 180 VAC
Acceptable Input Voltage Range                                                                    90 - 280 VAC or 170 - 280 VAC
Frequency Range                                                                                    50 Hz/60 Hz (Auto sensing)
Maximum AC Input Current                                                    20 A                               30 A                                40 A
PV INPUT (DC)
Maximum DC Voltage                                                         400 VDC                          450 VDC                              500 VDC
MPP Voltage Range                                                     120 VDC ~ 400 VDC                120 VDC ~ 400 VDC                    120 VDC ~ 450 VDC
Number of MPP Trackers / Maximum Input Current                              1 / 10A                          1 / 18A                              1 / 27A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage                                                                                   220/230/240 VAC
Output Waveform                                                                                           Pure sine wave
                                                                            92%                                92%                                93%
HYBRID OPERATION
PV INPUT (DC)
Maximum DC Voltage                                                        400 VDC                            450 VDC                            500 VDC
Start-up Voltage / Initial Feeding Voltage                                                              120 VDC / 150 VDC
MPP Voltage Range                                                     120 VDC ~ 400 VDC                120 VDC ~ 400 VDC                    120 VDC ~ 450 VDC
Number of MPP Trackers / Maximum Input Current                              1 / 10A                           1 / 18A                             1 / 27A
GRID OUTPUT (AC)
Nominal Output Voltage                                                                                  220/230/240 VAC
Output Voltage Range                                                                      184 - 264.5 VAC or 195.5 - 253 VAC (Selectable)
Nominal Output Current                                                      8.7A                               13A                                21.7A
AC INPUT
AC Start-up Voltage / Auto Restart Voltage                                                           120 - 140 VAC / 180 VAC
Acceptable Input Voltage Range                                                                    90 - 280 VAC or 170 - 280 VAC
Maximum AC Input Current                                                    20 A                               30 A                               40 A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage                                                                                   220/230/240 VAC
                                                                            92%                                92%                                93%
BATTERY & CHARGER
Nominal DC Voltage                                                                                           48 VDC
Maximum Charging Current                                                    40 A                              60 A                                80 A
GENERAL
PHYSICAL
Dimension, D x W x H (mm)                                                                               200 x 350 x 592.7
Net Weight (kgs)                                                                                               20
INTERACE
Parallel Function                                                                                         Yes, 9 units
Communication Port                                                                             USB or RS-232 / Dry Contact/RS485
ENVIRONMENT
Humidity                                                                                           0 ~ 95% RH (No condensing)
Operating Temperature                                                                                     -25°C to 50°C
Product specifications are subject to change without further notice
INF-VII
Feed-in Grid inverter with Energy Storage at Good Price/Performance
GRID-TIE OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage                       120 VDC / 400 VDC   240 VDC / 450 VDC              360 VDC / 450 VDC             360 VDC / 450 VDC     60 VDC / 450 VDC
Start-up Voltage / Initial Feeding Voltage                     130VDC / 150 VDC   130VDC / 150 VDC                130VDC / 150 VDC             130VDC / 150 VDC      130VDC / 150 VDC
MPP Voltage Range                                             120 VDC ~ 380 VDC   90 VDC ~ 430 VDC               120 VDC ~ 430 VDC            120 VDC ~ 430 VDC      120 VDC ~ 430 VDC
Number of MPP Trackers / Maximum Input Current                     1 / 18 A            1 / 18 A                        1 / 18A                      1 / 18A                1 / 23A
GRID OUTPUT (AC)
Nominal Output Voltage                                                                                            220/230/240 VAC
Output Voltage Range                                                                                184 - 264.5 VAC or 195.5 - 253 VAC (Selectable)
Nominal Output Current                                                 6.5A             8.7A                             13A                             13A                21.7A
Power Factor                                                                                                            > 0.99
EFFICIENCY
                                                                                                                         95%
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage / Auto Restart Voltage                                                                     120 - 140 VAC / 180 VAC
Acceptable Input Voltage Range                                                                              90 - 280 VAC or 170 - 280 VAC
Frequency Range                                                                                              50 Hz/60 Hz (Auto sensing)
Maximum AC Input Current                                               30 A             30 A                             40 A                            40 A                40 A
PV INPUT (DC)
Maximum DC Voltage                                                 400 VDC            450 VDC                         450 VDC                      450 VDC                450 VDC
MPP Voltage Range                                             120 VDC ~ 380 VDC   90 VDC ~ 430 VDC               120 VDC ~ 430 VDC            120 VDC ~ 430 VDC      120 VDC ~ 430 VDC
Number of MPP Trackers / Maximum Input Current                      1 / 18 A           1 / 18 A                        1 / 18 A                     1 / 18 A               1 / 23A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage                                                                                             220/230/240 VAC
Output Waveform                                                                                                     Pure sine wave
                                                                       93%              93%                              93%                             93%                93%
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage                       120 VDC / 400 VDC   240 VDC / 450 VDC              360 VDC / 450 VDC            360 VDC / 450 VDC       360 VDC / 450 VDC
Start-up Voltage / Initial Feeding Voltage                     130VDC / 150 VDC   130VDC / 150 VDC                130VDC / 150 VDC             130VDC / 150 VDC       120VDC / 150 VDC
MPP Voltage Range                                             120 VDC ~ 380 VDC   90 VDC ~ 430 VDC               120 VDC ~ 430 VDC            120 VDC ~ 430 VDC      120 VDC ~ 430 VDC
Number of MPP Trackers / Maximum Input Current                     1 / 18 A            1 / 18 A                        1 / 18A                      1 / 18A                1 / 23A
GRID OUTPUT (AC)
Nominal Output Voltage                                                                                            220/230/240 VAC
Output Voltage Range                                                                                184 - 264.5 VAC or 195.5 - 253 VAC (Selectable)
Nominal Output Current                                                 6.5A             8.7A                             13A                             13A                21.7A
AC INPUT
AC Start-up Voltage / Auto Restart Voltage                                                                     120 - 140 VAC / 180 VAC
Acceptable Input Voltage Range                                                                              90 - 280 VAC or 170 - 280 VAC
Maximum AC Input Current                                               30 A             30 A                             40 A                            40 A               40 A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage                                                                                             220/230/240 VAC
                                                                       93%              93%                              93%                             93%                93%
BATTERY & CHARGER
Nominal DC Voltage                                                    48 VDC           48 VDC                          24 VDC                          48 VDC             48 VDC
Maximum Solar Charging Current                                          30A             60 A                            60 A                            60 A               100 A
Maximum AC Charging Current                                             40A             60 A                            60 A                            60 A               100 A
Maximum Charging Current                                                40A             60 A                            60 A                            60 A               100 A
GENERAL
PHYSICAL
Dimension, D x W x H (mm)                                       100 x 300 x 440    120 x 295 x 468                 120 x 295 x 468               120 x 295 x 468       120 x 295 x 468
Net Weight (kgs)                                                       8                  11                              11                            11                    12
INTERACE
Parallel Function                                                      N/A           Yes, 9 units                    Yes, 9 units                     Yes, 9 units       Yes, 9 units
Communication Port                                                                                            USB or RS-232/Dry Contact
ENVIRONMENT
Humidity                                                                                                     0 ~ 90% RH (No condensing)
Operating Temperature                                                                                               -10°C to 50°C
Product specifications are subject to change without further notice
INF
On-grid Inverter with Energy Storage Selection
  GRID-TIE OPERATION
  PV INPUT (DC)
  Nominal DC Voltage / Maximum DC Voltage                             360 VDC / 500 VDC                                                  720 VDC / 900 VDC
  Start-up Voltage / Initial Feeding Voltage                          116 VDC / 150 VDC                           225 VDC / 250 VDC                            320 VDC / 350 VDC
  MPP Voltage Range                                                   250 VDC ~ 450 VDC                           250 VDC ~ 850 VDC                            400 VDC ~ 800 VDC
  Number of MPP Trackers / Maximum Input Current                          1 / 1 x 18A                                 2 / 2 x 10A                                  2 / 2 x 18.6A
  GRID OUTPUT (AC)
  Nominal Output Voltage                                                                    208/220/230/240 VAC                                            230 VAC (P-N) / 400 VAC (P-P)
  Output Voltage Range                                                                         184 - 265 VAC*                                                184 - 265 VAC* per phase
  Nominal Output Current                                                       13A                                         21A                                    14.5A per phase
  Power Factor                                                                                                            > 0.99
  EFFICIENCY
  Maximum Conversion Efficiency (DC/AC)                                                                                    96%
  European Efficiency@ Vnominal                                                                                            95%
  OFF-GRID OPERATION
  AC INPUT
                                                                                                                                                            120 - 140 VAC per phase /
  AC Start-up Voltage / Auto Restart Voltage                                               120 - 140 VAC / 180 VAC
                                                                                                                                                               180 VAC per phase
  Acceptable Input Voltage Range                                                                170 -280 VAC                                                 170 -280 VAC per phase
  Maximum AC Input Current                                                    30 A                                                               40 A
  PV INPUT (DC)
  Maximum DC Voltage                                                       500 VDC                                                           900 VDC
  MPP Voltage Range                                                   250 VDC ~ 850 VDC                           250 VDC ~ 850 VDC                            400 VDC ~ 800 VDC
  Number of MPP Trackers / Maximum Input Current                          1 / 1 x 18A                                 2 / 2 x 10A                                  2 / 2 x 18.6A
  BATTERY MODE OUTPUT (AC)
  Nominal Output Voltage                                                                   202/208/220/230/240 VAC                                        230 VAC (P-N) / 400 VAC (P-P)
  Output Waveform                                                                                                     Pure sine wave
  Efficiency (DC to AC)                                                                              93%                                                               91%
  HYBRID OPERATION
  PV INPUT (DC)
  Nominal DC Voltage / Maximum DC Voltage                             360 VDC / 500 VDC                                                  720 VDC / 900 VDC
  Start-up Voltage / Initial Feeding Voltage                          116 VDC / 150 VDC                            225 VDC / 250 VDC                           320 VDC / 350 VDC
  MPP Voltage Range                                                   250 VDC ~ 450 VDC                            250 VDC ~ 850 VDC                           400 VDC ~ 800 VDC
  Number of MPP Trackers / Maximum Input Current                          1 / 1 x 18A                                  2 / 2 x 10A                                 2 / 2 x 18.6A
  GENERAL
  PHYSICAL
  Dimension, D X W X H (mm)                                              107 x 438 x 480                             204.2 x 460 x 600                           167.2 x 500 x 622
  Net Weight (kgs)                                                             15.5                                         29                                           45
  INTERACE
  Communication Port                                                      RS-232/USB                                               RS-232/USB and CAN Interface
  Intelligent Slot                                                                                Optional SNMP, Modbus and AS-400 cards available
  ENVIRONMENT
  Humidity                                                                                                     0 ~ 90% RH (No condensing)
  Operating Temperature                                                     0 to 40°C                                                       -10 to 55°C
  Altitude                                                                                                             0 ~ 1000 m**
*These figures may vary depending on different AC voltage and country requirements.                                                                                         VDE-AR-N 4105
                                                                                                                                                                            VDE 0126-1-1
** Power derating 1% every 100 m when altitude is over 1000m
Product specifications are subject to change without further notice                                                                                                AS4777, AS/NZS3100, NRS-097-2-1
                                                                                                                                                                   (only for InfiniSolar Plus 3KW)
                                                                                           KEY FEATURES
                                               DP VIII SERIES
                                                                                                                                              120-500V
                                                                                               WIFI       Lithium Battery       6KW MPPT    Wide PV Input
                                                                                                                                              No need
                                                                                               GPRS           PF=1.0            100A MPPT     battery
     World’s Tier 1 barand               World’s Tier 1 barand
                                                                               ANTI DUST
                                                                                  KIT      TECHNICAL DATA
DP VIII-3500W DP VIII-5500W
APP
DP VMIII-3500W DP VMIII-5500W
                                                                       12
                                                                      months warranty
C US
                       E-mail: www.omegapowerus.com
56
55
                                                Lahore
                                    13-A, Canal Park, Gulberg II, Lahore
          Sheikhpura                                                       Faisalabad
                                                                Rehman Center, Zia Town,Street# 2,
Barki Road, Near regal Cinema, Sheikhpura
                                                                     Kashmir Pull , Faisalabad
UAN: 0304-111016, Cell # 03362757577
                                                             UAN: 0304-111016, Cell # 03362757577
              Karachi                                                      Islamabad
1/F/6, Block 6, P.E.C.H.S , Shahrah-e-Faisal,                   House# 5, Main Ibn-e-Sina Road, G10/3,
                   Karchi                                                    Islamabad.
  UAN: 0304-111016, Cell # 03362757577                          UAN: 0304-111016, Cell # 03362757577