Closet Connector Housings (CCH)

|
TRAINING
A LANscape ®
Solutions Product

Designed based on thousands of hours of voice of

|
SPLICE EQUIPMENT
customer feedback, Corning Cable Systems Closet
Connector Housings (CCHs) offer more than two
dozen innovative features that make installation and
troubleshooting of fiber optic connectivity faster, easier
and more cost-effective. From fiber and cable routing
and strain relief to port labeling and termination, these

|
TEST EQUIPMENT
housings reduce the risk of error that can disrupt
networks.

|
SPLICE CLOSURES
page 3 page 5

|
HARDWARE
|
CABLE ASSEMBLIES
|
CONNECTORS
|
CABLES
|
PRETERMINATED SYSTEMS

page 7 page 11

LANscape® Solutions | Photo MM003

SPECIFICATION SHEET LAN-1129-EN | PAGE 1


|
Closet Connector Housings (CCH) A LANscape ®
Solutions Product

features and benefits | Closet Connector Housings


Corning Cable Systems Closet Connector Housings
Interconnect and cross- Ideal for field
connect capability connectorization (CCHs) provide interconnect or cross-connect
capabilities between outside plant, riser or distribution
Removable, translucent Visibility and ease of cables and opto-electronics. Like all LANscape®
top covers (1U, 2U, 3U) access for installation, Solutions hardware, the housings accept CCH
and removable rear testing and trouble-
cover (4U) shooting connector panels. In addition, the housings accept
CCH cassettes and CCH modules.
Internal and external Flexibility for installation
strain-relief options and moves, adds and
changes (MACs)

Accepts panels, Variety of field


modules and cassettes termination options

Adaptable to use as a Splices are stored


modular splice housing and protected in
same footprint

Corning Cable Systems CCH Hardware Includes the CCH-01U with Translucent Top (Covers Partially
CCH-01U, CCH-02U, CCH-03U, CCH-04U | Photo LAN2511 Open) | Photo LAN2337

SPECIFICATION SHEET LAN-1129-EN | PAGE 2


Closet Connector Housings (CCH)

|
TRAINING
A LANscape ®
Solutions Product

The units are designed for rack mounting in 19-in

|
SPLICE EQUIPMENT
(48 cm) racks or optional 23-in (58 cm) equipment racks
(1.75-in EIA hole spacing). They are available in rack
space options of 1U (two panels, cassettes or modules),
2U (four panels, cassettes or modules), 3U (six panels,
cassettes or modules) and 4U (twelve panels, cassettes
or modules). The 1U, 2U and 3U options feature a

|
TEST EQUIPMENT
slide-out tray and see-through, removable top covers.
The CCH-04U features a clear door, removable front
and rear enclosures and a platinum-colored interior for
maximum visibility and access.

|
Documentation labels are provided and components

SPLICE CLOSURES
CCH-03U Installed with Splice Cassettes
can be added as needed to construct a fiber distribution | Photo LAN2519
frame for any application. All housings include a
removable tinted polycarbonate front door. All housings
have field-installable lock kits available for both front
and rear doors.

|
HARDWARE
Every CCH housing is shipped complete with strain-
relief brackets, routing clips and guides and mounting
brackets for proper installation.

|
CABLE ASSEMBLIES
CCH-04U Installed with CCH Connector Panels
(Sold Separately) | Photo LAN2616

|
CONNECTORS
specifications and ordering information |
Dimensions (H x W x D) Shipping Weight
cm (in) kg (lb) |
CABLES

CCH-01U 4.4 x 48 x 43 (1.75 x 19 x 17) 5.0 (11.0)


|

CCH-02U 8.9 x 48 x 43 (3.5 x 19 x 17) 6.5 (14.2)


PRETERMINATED SYSTEMS

CCH-03U 13.3 x 48 x 43 (5.25 x 19 x 17) 7.75 (17.0)

CCH-04U 17.8 x 48 x 43 (7 x 19 x 17) 8.0 (17.6)

SPECIFICATION SHEET LAN-1129-EN | PAGE 3


|
Closet Connector Housings (CCH) A LANscape ®
Solutions Product

specifications and ordering information | (continued)


Part Number Description

Closet Connector Housings

CCH-01U Closet Connector Housing; accepts up to 2 CCH panels, cassettes or modules;


comes with blank panels and hardware to strain-relieve cables internally or externally

CCH-02U Closet Connector Housing; accepts up to 4 CCH panels, cassettes or modules;


comes with blank panels and hardware to strain-relieve cables internally or externally

CCH-03U Closet Connector Housing; accepts up to 6 CCH panels, cassettes or modules;


comes with blank panels and hardware to strain-relieve cables internally or externally

CCH-04U Closet Connector Housing; accepts up to 12 CCH panels, cassettes or modules;


comes with blank panels and hardware to strain-relieve cables internally or externally

If you need the previous CCH housing (pre-January 2012), use the following part numbers (see LAN-1392-EN):

Part Number Description

Classic Closet Connector Housings


CLSSC-01U Classic Closet Connector Housing; accepts up to 2 CCH panels; comes with blank panels and
hardware to strain relieve 1 cable with the universal cable clamp (UCC) or up to (5) 0.4 in or
smaller cables with the UCC insert. Does not accept CCH cassettes.

CLSSC-02U Classic Closet Connector Housing; accepts up to 4 CCH panels; comes with blank panels and
hardware to strain relieve 1 cable with the universal cable clamp (UCC) or up to (5) 0.4 in or
smaller cables with the UCC insert. Does not accept CCH cassettes.

CLSSC-03U Classic Closet Connector Housing; accepts up to 6 CCH panels; comes with blank panels and
hardware to strain relieve 1 cable with the universal cable clamp (UCC) or up to (5) 0.4 in or
smaller cables with the UCC insert. Does not accept CCH cassettes.

CLSSC-04U Classic Closet Connector Housing; accepts up to 12 CCH panels; comes with blank panels
and hardware to strain relieve 1 cable with the universal cable clamp (UCC) or up to (5) 0.4 in
or smaller cables with the UCC insert. Does not accept CCH cassettes.

SPECIFICATION SHEET LAN-1129-EN | PAGE 4


Closet Connector Housings (CCH)

|
TRAINING
A LANscape ®
Solutions Product

CCH Cassettes

|
SPLICE EQUIPMENT
CCH Splice Cassettes enable fast field termination
and easy modular management of connectorization
within the housing.

The CCH Splice Cassette supports fusion splicing

|
of individual or ribbon fibers, with heat shrinks, pigtail

TEST EQUIPMENT
slack and cable slack managed within a single space-
saving footprint. This eliminates the need for individual
splice trays or separate splice housings, as well as
allowing splicing to be done away from the rack housing
in a suitable workspace as needed. The modular design

|
makes it easy to access the fiber in an individual cassette

SPLICE CLOSURES
without disturbing the other fibers in the housing.
A CCH panel with the desired adapter configuration can
be ordered separately and fits easily into the cassette. CCH Splice Cassette | Photo LAN2452

Each cassette is shipped with 1 rail for use with CCH-

|
HARDWARE
01U/2U/3U housings, and 2 rails used with CCH-04U
housings. Grommets and cable ties for additional strain
relief and protective tubing for incoming cable are also

|
included. Splice cassettes ship with 12 single-fiber

CABLE ASSEMBLIES
heat-shrink splice protectors.

CCH Slack Cassette


A CCH Slack Cassette option with no splice tray,
suitable for use with field-installable connectors, is also

|
available. The Slack Cassette is an economical way to

CONNECTORS
provide modularity, segregation and added protection
and security to your direct terminated fibers inside of
any of the 4 CCH housing options.
|
CABLES
Each cassette is shipped with 1 rail for use with CCH-
01U/2U/3U housings, and 2 rails used with CCH-04U CCH Slack Cassette | Photo LAN2984
housings. Grommets and cable ties for additional strain
|

relief and protective tubing for incoming cable are also


PRETERMINATED SYSTEMS

included.

SPECIFICATION SHEET LAN-1129-EN | PAGE 5


|
Closet Connector Housings (CCH) A LANscape ®
Solutions Product

specifications and ordering information |


Part Number Description

CCH-CS CCH Splicing Cassette; accepts 1 CCH Panel and up to 24 single-fiber or 6 ribbon heat-shrink
splice protectors; comes with 12 single-fiber heat-shrink splice protectors, grommets and cable
ties for strain relief, protective braided tubing, 1 rail for use with CCH-01U/2U/3U housings and
2 rails used with CCH-04U housings

CCH-CF CCH Slack Storage Cassette; accepts 1 CCH Panel and provides modular slack storage for
direct factory or field termination of incoming (e.g., distribution) cables; comes with grommets
and cable ties for strain-relief, protective braided tubing, 1 rail for use with CCH-01U/2U/3U
housings and 2 rails used with CCH-04U housings

Dimensions (H x W x D) Shipping Weight


cm (in) kg (lb)

CCH-CS 16.2 x 3.5 x 20 (6.4 x 1.4 x 7.9) 0.5 (1)

CCH-CF 16.2 x 3.5 x 20 (6.4 x 1.4 x 7.9) 0.5 (1)

SPECIFICATION SHEET LAN-1129-EN | PAGE 6


Closet Connector Housings (CCH)

|
TRAINING
A LANscape ®
Solutions Product

CCH Pigtailed Cassettes

|
SPLICE EQUIPMENT
CCH Pigtailed Splice Cassettes enable faster
field splicing and easy modular management of
connectorization within the housing.

The CCH Pigtailed Splice Cassettes are pre-loaded and

|
pre-routed for quick fusion splicing of either individual

TEST EQUIPMENT
or ribbon fiber pigtails, utilizing the same space-saving
platform as the standard CCH Splice Cassette.

The pre-routed Pigtailed Cassettes reduce field labor by


streamlining the features and components of the pigtail

|
cassette to allow for efficiencies in the field. They are

SPLICE CLOSURES
loaded with a pigtail assembly and a CCH Connector
Panel. The pigtails have 900 µm protection at the
connector panel for added durability, routed into the CCH Pigtailed Cassette | Photo LAN2741
splice tray layer, where it transitions to either 250 µm
fiber or bare ribbon (depending on the splicing method

|
HARDWARE
desired) for ease of splicing.

The Pigtailed Cassette allows the elimination of

|
individual splice trays or separate splice housings,

CABLE ASSEMBLIES
as well as allowing splicing to be done away from the
rack housing in a suitable workspace as needed. The
modular design makes it easy to access the fiber in an
individual cassette without disturbing the other fibers in
the housing.

|
CONNECTORS
Each cassette is shipped with the CCH Connector
Panel and choice of pigtails, 1 rail for use with CCH-
01U/2U/3U housings, and 2 rails used with CCH-04U
housings. Grommets and cable ties for additional strain
|
relief and protective tubing for incoming cable are also
CABLES

included. Splicing cassettes ship with the appropriate CCH Pigtailed Cassette | Photo LAN2593
number and type of fiber heat-shrink splice protectors.
|
PRETERMINATED SYSTEMS

SPECIFICATION SHEET LAN-1129-EN | PAGE 7


|
Closet Connector Housings (CCH) A LANscape ®
Solutions Product

specifications and ordering information |


Pigtailed Splice Cassettes (CCH-CS)
CCH Splice Cassette (CCH-CS) loaded with CCH panel and factory-terminated pigtails. Available with ribbon or
single-fiber splicing configurations. Includes appropriate number and type of heat shrinks and protective tubing
depending on fiber count and cable type. See matrix on the next page to build your part number.

Multimode

Loss 0.35 dB typical (all fibers) at 1300 nm, 0.5 dB max*

Single-Mode

Loss 0.15 dB typical (all fibers) at 1310 nm, 0.4 dB max*

The following 6 products are in the core CCH product set and are stocked at our distributors for
immediate availability.

Part Number Description Type

CCH-CS12-59-P00RE 12 F, SC, UPC, Duplex, Single-mode (OS2), Rack-Mountable


Single-fiber (250 µm) Hardware

CCH-CS12-6T-P00RE 12 F, ST® Compatible, UPC, Simplex, Single-mode (OS2), Rack-Mountable


Single-fiber (250 µm) Hardware

CCH-CS12-A9-P00RE 12 F, LC, UPC, Duplex, Single-mode (OS2), Rack-Mountable


Single-fiber (250 µm) Hardware

CCH-CS24-A9-P00RE 24 F, LC, UPC, Duplex, Single-mode (OS2), Rack-Mountable


Single-fiber (250 µm) Hardware

CCH-CS12-E4-P00TE 12 F, LC, PC, Duplex, 50 µm (OM3), Single-fiber (250 µm) Rack-Mountable


Hardware

CCH-CS24-E4-P00TE 24 F, LC, PC, Duplex, 50 µm (OM3), Single-fiber (250 µm) Rack-Mountable


Hardware

Dimensions (H x W x D) Shipping Weight


cm (in) kg (lb)

CCH-CS - - P00 16.2 x 3.5 x 20 (6.4 x 1.4 x 7.9) 0.75 (1.5)

SPECIFICATION SHEET LAN-1129-EN | PAGE 8


Closet Connector Housings (CCH)

|
TRAINING
A LANscape ®
Solutions Product

ordering information | (continued)

|
SPLICE EQUIPMENT
CCH Pigtailed Splice Cassettes

CCH - CS - - P00
|1 |2 |3 |4

|
TEST EQUIPMENT
|1 |3 Note:
1) Fiber count for desired
adapter is available in table
Select fiber count. Select fiber type. on following page.
06 = 6 fibers K = 625 µm multimode (OM1)
08 = 8 fibers B = 50 µm multimode (OM2)
12 = 12 fibers T = 50 µm multimode (OM3)

|
16 = 16 fibers Q = 50 µm multimode (OM4)

SPLICE CLOSURES
24 = 24 fibers R = Single-mode (OS2)
See Note 1

|2 |4
Select adapter code Select splicing type.
(see Adapter/Connector E = Single fiber splicing

|
J = Ribbon splicing (only

HARDWARE
Code Options table on for fiber counts of 12
following page). or 24)

|
CABLE ASSEMBLIES
Part Number Description

Part Number Examples


CCH-CS12-59-P00RE Closet Connector Housing Pigtail Cassette with 6 SC duplex single-mode adapters,

|
with 12 single-mode SC pigtails routed inside the cassette for single-fiber splicing

CONNECTORS
CCH-CS24-E4-P00TE Closet Connector Housing Pigtail Cassette with 12 LC duplex aqua OM3/4 adapters,
with 24 OM3 LC pigtails routed inside the cassette for single-fiber splicing

|
CABLES
|
PRETERMINATED SYSTEMS

SPECIFICATION SHEET LAN-1129-EN | PAGE 9


|
Closet Connector Housings (CCH) A LANscape ®
Solutions Product

adapter/connector code options |


Available Fiber/Panel Counts
Adapter Fiber/
Code Fiber Type Alignment Housing Adapter 6 8 12 16 24

LC Duplex
A8 62.5 µm multimode (OM1) Ceramic Composite 2 X X X X X
D3 50 µm multimode (OM2) Ceramic Composite 2 X X X X X
E4 50 µm multimode (OM3/4) Ceramic Composite 2 X X X X X
A9 Single-mode, UPC (OS2) Ceramic Composite 2 X X X X X
B3 Single-mode, APC (OS2) Ceramic Composite 2 X X X X X

SC Duplex
91 62.5 µm multimode (OM1) Metal Composite 2 X X X
G7 50 µm multimode (OM2) Ceramic Composite 2 X X X
E7 50 µm multimode (OM3/4) Ceramic Composite 2 X X X
59 Single-mode, UPC (OS2) Ceramic Composite 2 X X X
D9 Single-mode, APC (OS2) Ceramic Composite 2 X X X

SC
56 62.5 µm multimode (OM1) Metal Composite 1 X X X
G6 50 µm multimode (OM2) Ceramic Composite 1 X X X
E6 50 µm multimode (OM3/4) Ceramic Composite 1 X X X
3C Single-mode, UPC (OS2) Ceramic Composite 1 X X X
6C Single-mode, APC (OS2) Ceramic Composite 1 X X X

ST ® Compatible Connector
5T 62.5 µm multimode (OM1) Ceramic Metal 1 X X X
G5 50 µm multimode (OM2) Ceramic Metal 1 X X X
H3 50 µm multimode (OM3/4) Ceramic Metal 1 X X X
6T Single-mode, UPC (OS2) Ceramic Metal 1 X X X

FC
11 Single-mode, UPC (OS2) Metal Metal 1 X X X
21 Single-mode, APC (OS2) Metal Metal 1 X X X

MT-RJ, pinned
97 62.5 µm multimode (OM1) N/A Composite 2 X X X X
G1 50 µm multimode (OM2) N/A Composite 2 X X X X
E1 50 µm multimode (OM3/4) N/A Composite 2 X X X X
98 Single-mode, UPC (OS2) N/A Composite 2 X X X X

Fiber Type Housing Color

62.5 µm multimode (OM1) Beige


50 µm multimode (OM2) Black
50 µm multimode (OM3/4) Aqua
Single-mode, UPC (OS2) Blue
Single-mode, APC Green

Note: For keyed LC ordering information, please refer to LAN-701-EN.

SPECIFICATION SHEET LAN-1129-EN | PAGE 10


Closet Connector Housings (CCH)

|
TRAINING
A LANscape ®
Solutions Product

ordering information | (continued)

|
SPLICE EQUIPMENT
Part Number Description

Accessories

Strain Relief

|
UCC-001 Universal Cable Clamp Kit for use with external strain-relief bracket

TEST EQUIPMENT
of CCH housings. Includes one UCC clamp and inserts for one
cable up to 1.125-in diameter or up to five 0.4-in or smaller cables.

CPP-SSR-KIT Central Member Strain-Relief Kit. Includes one clamp, washers


and screw to attach to CCH internal strain-relief bracket.

|
SPLICE CLOSURES
Mounting

CCH1-RECESS-KIT-5 Includes 5 pairs of brackets to recess mount 5 CCH-01U housings

CCH2-RECESS-KIT-5 Includes 5 pairs of brackets to recess mount 5 CCH-02U housings

|
HARDWARE
CCH3-RECESS-KIT-5 Includes 5 pairs of brackets to recess mount 5 CCH-03U housings

|
CCH4-RECESS-KIT-5 Includes 5 pairs of brackets to recess mount 5 CCH-04U housings

CABLE ASSEMBLIES
CCH4-3INCH-KIT-5 Includes 5 pairs of brackets to mount 5 CCH-04U housings with
3-in frontal projection (standard CCH-04U frontal projection is 5-in)

CDF-01U-23-BKT 23-in Mounting Brackets for the CCH-01U

|
CONNECTORS
CDF-02U-23-BKT 23-in Mounting Brackets for the CCH-02U

|
CABLES

CDF-03U-23-BKT 23-in Mounting Brackets for the CCH-03U


|
PRETERMINATED SYSTEMS

CDF-04U-23-BKT 23-in Mounting Brackets for the CCH-04U

SPECIFICATION SHEET LAN-1129-EN | PAGE 11


|
Closet Connector Housings (CCH) A LANscape ®
Solutions Product

ordering information | (continued)


Part Number Description

Mounting

CDF-01U-24-BKT 24-in Mounting Brackets for the CCH-01U

CDF-02U-24-BKT 24-in Mounting Brackets for the CCH-02U

CDF-03U-24-BKT 24-in Mounting Brackets for the CCH-03U

CDF-04U-24-BKT 24-in Mounting Brackets for the CCH-04U

Miscellaneous

FDC-CABLE-GRND Armored Cable Grounding Kit; contains armored grounding clip


and ground strap

CCHA-LOCK-KIT CCH Hardware Lock Kit, compatible with CCH-01U, CCH-02U,


CCH-03U, CCH-04U front and rear doors

CJP-01U Closet Jumper Management Panel; provides jumper management


in a 1.75-in rack space

CJP-02U Closet Jumper Management Panel; provides jumper management


in a 3.5-in rack space

CJP-03U Closet Jumper Management Panel; provides jumper management


in a 5.25-in rack space

SPECIFICATION SHEET LAN-1129-EN | PAGE 12


Closet Connector Housings (CCH)

|
TRAINING
A LANscape ®
Solutions Product

ordering information | (continued)

|
SPLICE EQUIPMENT
Part Number Description

Replacement Parts
Covers and Doors

|
CCH1-TOP-COVER-2 Top Covers (2) for CCH-01U, CCH-02U and CCH-03U, with 2

TEST EQUIPMENT
label cards

CCH1-DOOR-FRONT Front Door for CCH-01U, includes hinges and latches

CCH2-DOOR-FRONT Front Door for CCH-02U, includes hinges and latches

|
SPLICE CLOSURES
CCH3-DOOR-FRONT Front Door for CCH-03U, includes hinges and latches

CCH4-DOOR-FRONT Front Door for CCH-04U, includes hinges and latches

|
HARDWARE
CCH1-DOOR-REAR Rear Door for CCH-01U, includes hinges and latches

|
CCH2-DOOR-REAR Rear Door for CCH-02U, includes hinges and latches

CABLE ASSEMBLIES
CCH3-DOOR-REAR Rear Door for CCH-03U, includes hinges and latches

CCH4-DOOR-REAR Rear Door for CCH-04U, includes hinges and latches

|
CONNECTORS
Labeling

CCH1-LABEL-CARD-20 Plastic Label Holder Cards for CCH-01U, CCH-02U, CCH-03U;


20 per pack
|
CABLES

CCH4-LABEL-CARD-20 Plastic Label Holder Cards for CCH-04U; 20 per pack


|

CCHA-LABEL-PNL-50 Additional Adhesive Labels for the CCH; contains 50 labels


PRETERMINATED SYSTEMS

SPECIFICATION SHEET LAN-1129-EN | PAGE 13


|
Closet Connector Housings (CCH) A LANscape ®
Solutions Product

ordering information | (continued)


Part Number Description

Strain Relief

CCH1-STRN-INT Internal Strain-relief Bracket for the CCH-01U, CCH-02U,


CCH-03U

CCH1-STRN-EXT External Strain-relief Bracket for the CCH-01U, CCH-02U,


CCH-03U

CCH4-STRN-INT Internal Strain-relief Bracket for the CCH-04U

CCH4-STRN-EXT External Strain-relief Bracket for the CCH-04U

CCHA-CLIP-BTF-2 Transitional Strain-relief Clip for CCH-01U, CCH-02U, CCH-03U,


CCH-04U; 2 per pack

Fiber and Cable Management

CCH1-CASS-RAIL 1 Stacker Rail for CCH-01U, CCH-02U, CCH-03U; for use with
CCH cassettes

CCH4-CASS-RAIL-24 Small Rails for CCH-04U; for use with CCH cassettes; 24 per pack

CCHA-CLIP-SLCK-8 Segregated Fiber Routing Clips for CCH-01U, CCH-02U,


CCH-03U, CCH-04U; 8 per pack

CCH1-GUIDE-JMPR-3 Front Jumper Routing Guide for the CCH-01U, CCH-02U,


CCH-03U; 3 per pack

CCH4-CLIP-JMPR-8 Front Jumper Routing Guide for the CCH-04U; 8 per pack

CCHA-CLIP-PNL-24 Panel Clips for the CCH-01U, CCH-02U, CCH-03U, CCH-04U;


24 per pack

SPECIFICATION SHEET LAN-1129-EN | PAGE 14


notes |

SPECIFICATION SHEET LAN-1129-EN | PAGE 15


Closet Connector Housings (CCH)
A LANscape ®
Solutions Product

| PRETERMINATED SYSTEMS | CABLES | CONNECTORS | CABLE ASSEMBLIES | HARDWARE | SPLICE CLOSURES | TEST EQUIPMENT | SPLICE EQUIPMENT | TRAINING |
Closet Connector Housings (CCH) A LANscape ®
Solutions Product

notes |

Corning Cable Systems LLC • PO Box 489 • Hickory, NC 28603-0489 USA


800-743-2675 • FAX: 828-325-5060 • International: +1-828-901-5000 • www.corning.com/cablesystems
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems products without prior notification. LANscape
is a registered trademark of Corning Cable Systems Brands, Inc. ST is a registered trademark of Lucent Technologies. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2012 Corning Cable Systems. All rights reserved. Published in the USA. LAN-1129-EN / October 2012

SPECIFICATION SHEET LAN-1129-EN | PAGE 16

You might also like