SPECIFICATION
1. ALL PLUMBING WORKS HEREIN SHALL CONFORM
FAU WITH THE LATEST NATIONAL PLUMBING CODE AS
LEGEND :
KS PER PD 1096
KS KITCHEN SINK
2. SEPTIC TANK WALLING ARE PROVIDED WITH HB HOSE BIB
10mmØ DEFORMED BARS SPACED AT 0.40m LAV LAVATORY
VERTICALLY AND 0.60m HORIZONTALY.
SH SHOWER
CO CLEAN OUT
SH 3. ALL PLUMBING FIXTURES & ACCESSORIES MUST
BEPHILIPPINE STANDARD & OF APPROVED TYPE. FD FLOOR DRAIN
TO SEWER
LINE FAU WC WATER CLOSET
WC FAU FAUCET
4. ALL INSTALLATION SHALL DONE UNDER THE
FD DIRECT SUPERVISION OF A REGISTERED COLD WATER LINE
MASTER PLUMBER. SANITARY PIPE LINES
CHECK VALVE
WATER METER
GATE VALVE
TO MAIN
WATER
SUPPLY LINE
SANITARY LAYOUT WATER DISTRIBUTION LAYOUT
SCALE 1:100 MTRS SCALE 1:100 MTRS
1 0.53 1 2.64
10mm Ø Deformed Bars
3 .51
Spaced @ 0.15m Both Ways.
1 0.53 3 .51
MH MH
PLAN
1 0.53 1 2.64
10mm Ø Deformed Bars 3 .51 3 .51
Spaced @ 0.40m O.C.
2 .12
2 .45
AIR SPACE
10mm Ø Deformed Bars
Every 2nd Layer
1 0.53 1 0.55
3-12mm Ø Deformed Bars
1 .08 2% SLOPE
ELEVATION
ISOMETRIC VIEW WATER LINE LAYOUT SEPTIC VAULT DETAIL
ISOMETRIC VIEW PLUMBING LAYOUT SCALE 1:100 MTRS
SCALE 1:100 MTRS SCALE 1:100 MTRS
SEAL CIVIL ENGINEER / MASTER PLUMBER: PROJECT TITTLE: APPROVED BY: SHEET CONTENTS: SHEET NO.
PRC NO:
PROPOSED RESIDENTIAL BUILDING AS INDICATED IN
PTR NO:
DATE: THE PLAN 5
TIN NO: LOCATION : OWNER