PART 1 GENERAL
A. Section 02 20 00 - Assessment.
C. Section 32 90 00 - Planting.
E. Division 16 - Electrical, electrical service and connections for motor operators, controls, limit
switches, other powered devices and for system disconnect switches.
1.3 REFERENCES
32 31 00 -1
5. ASTM A500: Standard Specification for Cold formed welded and seamless carbon
steel structural tubing in round shapes.
6. ASTM A513: Standard Specification for Electric-Resistance-Welded Carbon and Alloy
Steel Mechanical Tubing.
7. ASTM A641: Standard Specification for Zinc-Coated (Galvanized) Carbon Steel Wire.
8. ASTM A653: Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or
Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.
9. ASTM A787: Standard Specification for Electric-Resistance-Welded Metallic-Coated
Carbon Steel Mechanical Tubing.
10. ASTM A1008: Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy
(HSLA) and HSLA with Improved Formability.
11. ASTM B6: Standard Specification for Zinc.
12. ASTM B117: Standard Test Method of Salt Spray (Fog) Testing.
13. ASTM B221: Standard Specification for Aluminum and Aluminum-alloy extruded bars,
rods, wire, shapes and tubes.
14. ASTM D2247: Standard Practice for Testing Water Resistance of Coatings in 100%
Relative Humidity.
15. ASTM D2794: Standard Test Method for Resistance of Organic Coatings to the
Effects of Rapid Deformation (Impact).
16. ASTM D3359: Standard Test Methods for Measuring Adhesion by Tape.
17. ASTM F626: Standard Specification for Fence Fittings.
18. ASTM F900: Standard Specification for industrial and commercial swing gates.
19. ASTM F934: Standard Specification for Standard Colors for Polymer-Coated Chain
Link Fence Materials.
20. ASTM F1043: Standard Specification for Strength and Protective Coatings on Steel
Industrial Chain Link Fence Framework
21. ASTM F1184: Standard Specification for industrial and commercial horizontal slide
gates.
22. ASTM F1234: Standard Specification for protection coatings on steel framework for
fences.
23. ASTM F2919: Standard Specification for Welded Wire Mesh Fence Fabric (Metallic-
Coated or Polymer Coated) with Variable Mesh Patterns or Meshes Greater than 6
square inch (3871 mm2) in Panels.
1.4 SUBMITTALS
C. Shop Drawings:
32 31 00 -2
1. Show locations of fence, each gate, posts, rails, and details of gate swing, or other
operation, hardware, and accessories.
2. Indicate materials, dimensions, sizes, weights, and finishes of components.
3. Include plans, elevations, sections, gate swing and other required installation and
operational clearances, and details of post anchorage, attachment and bracing.
4. Installation procedures and instructions describing details for a typical fence and
gates.
5. Gate Operator: Show locations and details for installing operator components,
switches, and controls. Indicate motor size, electrical characteristics, drive
arrangement, mounting, and grounding provisions.
6. Wiring Diagrams: Power and control wiring, communication features, and access
control features. Differentiate between factory-installed and field-installed wiring and
between components provided by fence manufacturer and those provided by
sections.
D. Verification Samples: For each finish product specified, two samples, minimum size 6 inches
(150 mm) square or long, representing actual color.
E. Qualification Data: For firms and persons specified in "Quality Assurance" article to
demonstrate their capabilities and experience. Include lists of completed projects with project
names and addresses, names and addresses of architects and owners, and other
information specified.
A. Installer Qualifications: Minimum 2 years experience installing fences and gates similar in
material, design, and extent to those indicated for this Project and whose work has resulted
in construction with a record of successful in-service performance.
B. Source Limitations for Fences and Gates: Obtain each component for fences and gates from
one source with resources to provide fences and gates of consistent quality in appearance
and physical properties.
1. Electrical Components, Devices, and Accessories: listed and labeled as defined in
NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction,
and marked for intended use.
2. Provide gate operators that comply with UL 325.
C. Electrical Components, Devices, and Accessories: listed and labeled as defined in NFPA 70,
Article 100, by a testing agency acceptable to authorities having jurisdiction, and marked for
intended use.
32 31 00 -3
1.6 DELIVERY, STORAGE, AND HANDLING
A. Deliver and store products in manufacturer's tagged and unopened packaging until ready for
installation.
A. Existing Utilities: Do not interrupt utilities serving facilities occupied by Owner or others
unless permitted under the following conditions:
1. Notify local utility marking services before beginning work.
2. Unless otherwise indicated in the general provisions of the contract, notify Architect no
less than two days in advance of proposed utility interruptions.
3. Do not proceed with utility interruptions without Architect's written permission.
B. Field Measurements: Verify layout information for fences and gates shown on drawings in
relation to property survey and existing structures. Verify dimensions by field measurements.
1.8 WARRANTY
A. Manufacturer's Warranty: Provide manufacturer's standard ten year limited warranty for
finish.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Height:
1. 4 feet (1245 mm).
2. 5 feet (1549 mm).
3. 6 feet (1778 mm).
4. 8 feet (2464 mm).
5. Multiple stacked panels as shown on the Drawings.
32 31 00 -4
position. The other end is cut flush.
4. Panels shall have the following number of folds at 92.75 inches (2356 mm) wide
based on the panel height:
a. 4 feet (1245 mm): 2 folds.
b. 5 feet (1549 mm): 2 folds.
c. 6 feet (1778 mm): 3 folds.
d. 8 feet (2464 mm): 4 folds.
5. Panel camber may not exceed 0.094 inch (2.5 mm).
C. Square Posts: Cold rolled 1008 grade steel to meet ASTM 500 and ASTM A787 and the
following maximum horizontal loads, length as required for installation type:
1. Installation: In ground, post length as required for local frost line requirements.
2. Installation: Surface mounted, flanged.
3. Post Size: 2 x 2 inch (50 x 50 mm):
a. 16 gauge (1.6 mm), 329 pound (149 kg) maximum horizontal load.
b. 11 gauge (3.0 mm), 578 pound (262 kg) maximum horizontal load.
4. Post Size: 3 x 3 inch (75 x 75 mm):
a. 11 gauge (3.0 mm), 1383 pound (627 kg) maximum horizontal load.
5. Post Size: 2 x 2 inch (50 x 50 mm):
a. 16 gauge (1.6 mm), 263 pound (119 kg) maximum horizontal load.
b. 11 gauge (3.0 mm), 463 pound (210 kg) maximum horizontal load.
6. Post Size: 3 x 3 inch (75 x 75 mm):
a. 11 gauge (3.0 mm), 1106 pound (501 kg) maximum horizontal load.
7. Post Size: 2 x 2 inch (50 x 50 mm):
a. 11 gauge (3.0 mm), 385 pound (175 kg) maximum horizontal load.
8. Post Size: 3 x 3 inch (75 x 75 mm):
a. 11 gauge (3.0 mm), 922 pound (418 kg) maximum horizontal load.
9. Post Size: 2 x 2 inch (50 x 50 mm):
a. 11 gauge (3.0 mm), 289 pound (131 kg) maximum horizontal load.
10. Post Size: 3 x 3 inch (75 x 75 mm):
a. 11 gauge (3.0 mm), 691 pound (313 kg) maximum horizontal load.
D. Post Brackets:
1. Universal Post Bracket Kit, Includes the following: 13 gauge (2.4mm) steel collar, nut,
washer and carriage bolt 1/4 x 1-1/4 inch (6.4 x 32 mm), all galvanized steel.
a. For 90 degrees turns, use the same bracket.
b. For 4 foot (1245 mm) high panels: Provide 4 brackets per panel.
c. For 5 foot (1549 mm) high panels: Provide 6 brackets per panel.
d. For 6 foot (1778 mm) high panels: Provide 6 brackets per panel.
e. For 8 foot (2464 mm) high panels: Provide 8 brackets per panel.
2. U-Shaped Bracket Kit, Includes the following: Stainless steel U rod 5/16 inch (8 mm)
diameter, rear flange in PVC 1-1/2" x 1-1/8 inches (37.8 x 28.4 mm), forehead support
in PVC 5/8" x 1-1/16 (15.2 x 27.5 mm) cosmetic plastic caps and nuts (M8).
a. For 4 foot (1245 mm) high panels: Provide 4 brackets per panel.
b. For 4 foot (1230 mm) high panels: Provide 6 brackets per panel.
c. For 5 foot (1549 mm) high panels: Provide 6 brackets per panel.
d. For 6 foot (1778 mm) high panels: Provide 6 brackets per panel.
e. For 8 foot (2464 mm) high panels: Provide 8 brackets per panel.
E. Special Panel Fittings (SPF): Hot dipped galvanized steel enable panels to be fastened to
any vertical or horizontal surface, such as steel or concrete beams or wood posts. Provide
the following model:
1. SPF-W Kit: For mounting on a vertical surface, consisting of an L-shaped slotted
plate, which accommodates a 1-3/4'' (45 mm) vertical adjustment and a retaining plate
that hold two vertical wires when bolted together.
2. SPF-C Kit: for horizontal surfaces, uses the same "L" shaped slotted plate and 2 wire
32 31 00 -5
retaining plates.
3. SPF-P Kit: connects two panels together.
F. Post Caps:
1. Aluminum alloy.
2. Galvanized steel.
G. Overhang Extension:
1. Same dimensions as the post, minimum 18 in. (460 mm) long, welded to the end
square posts to form a 45 degrees angle to receive a panel of 16 in. (420 mm).
2. Provide with two fastener kits.
H. Architectural mesh panels and posts shall be zinc-coated steel wire conforming to
specification ASTM A641 (1989) Class 1, and with 4 mils polyester powder coating as
specified below.
A. Height:
1. 4 feet (1230 mm).
2. 6 feet (1830 mm).
3. 8 feet (2430 mm).
4. Multiple stacked panels as shown on the Drawings.
C. Square Posts: Cold rolled 1008 grade steel to meet ASTM 500 and ASTM A787 and the
following maximum horizontal loads, length as required for installation type:
1. Installation: In ground, post length as required for local frost line requirements.
2. Installation: Surface mounted, flanged.
3. Post Size: 2 x 2 inch (50 x 50 mm):
a. 16 gauge (1.6 mm), 329 pound (149 kg) maximum horizontal load.
b. 11 gauge (3.0 mm), 578 pound (262 kg) maximum horizontal load.
4. Post Size: 3 x 3 inch (75 x 75 mm):
a. 11 gauge (3.0 mm), 1383 pound (627 kg) maximum horizontal load.
5. Post Size: 2 x 2 inch (50 x 50 mm):
a. 16 gauge (1.6 mm), 263 pound (119 kg) maximum horizontal load.
b. 11 gauge (3.0 mm), 463 pound (210 kg) maximum horizontal load.
6. Post Size: 3 x 3 inch (75 x 75 mm):
a. 11 gauge (3.0 mm), 1106 pound (501 kg) maximum horizontal load.
7. Post Size: 2 x 2 inch (50 x 50 mm):
a. 11 gauge (3.0 mm), 385 pound (175 kg) maximum horizontal load.
8. Post Size: 3 x 3 inch (75 x 75 mm):
a. 11 gauge (3.0 mm), 922 pound (418 kg) maximum horizontal load.
9. Post Size: 2 x 2 inch (50 x 50 mm):
32 31 00 -6
a. 11 gauge (3.0 mm), 289 pound (131 kg) maximum horizontal load.
10. Post Size: 3 x 3 inch (75 x 75 mm):
a. 11 gauge (3.0 mm), 691 pound (313 kg) maximum horizontal load.
D. Post Brackets:
1. Universal Post Bracket Kit, Includes the following: 13 gauge (2.4mm) steel collar, nut,
washer and carriage bolt 1/4 x 1-1/4 inch (6.4 x 32 mm), all galvanized steel.
a. For 90 degrees turns, use the same bracket.
b. For different angles, use universal angle brackets.
c. For 4 foot (1230 mm) high panels: Provide 4 brackets per panel.
d. For 5 foot (1449 mm) high panels: Provide 6 brackets per panel.
e. For 6 foot (1830 mm) high panels: Provide 6 brackets per panel.
f. For 8 foot (2430 mm) high panels: Provide 8 brackets per panel.
2. U-Shaped Bracket Kit, Includes the following: Stainless steel U rod 5/16 inch (8 mm)
diameter, rear flange in PVC 1-1/2" x 1-1/8 inches (37.8 x 28.4 mm), forehead support
in PVC 5/8" x 1-1/16 (15.2 x 27.5 mm) cosmetic plastic caps and nuts (M8).
a. For 4 foot (1230 mm) high panels: Provide 4 brackets per panel.
b. For 4 foot (1230 mm) high panels: Provide 6 brackets per panel.
c. For 5 foot (1449 mm) high panels: Provide 6 brackets per panel.
d. For 6 foot (1830 mm) high panels: Provide 6 brackets per panel.
e. For 8 foot (2430 mm) high panels: Provide 8 brackets per panel.
E. Special Panel Fittings (SPF): Hot dipped galvanized steel enable panels to be fastened to
any vertical or horizontal surface, such as steel or concrete beams or wood posts. Provide
the following model:
1. SPF-W Kit: For mounting on a vertical surface, consisting of an L-shaped slotted
plate, which accommodates a 1-3/4'' (45 mm) vertical adjustment and a retaining plate
that hold two vertical wires when bolted together.
2. SPF-C Kit: for horizontal surfaces, uses the same "L" shaped slotted plate and 2 wire
retaining plates.
3. SPF-P Kit: connects two panels together.
F. Post Caps:
1. Aluminum alloy.
2. Galvanized steel.
G. Overhang Extension:
1. Same dimensions as the post, minimum 18 in. (460 mm) long, welded to the end
square posts to form a 45 degrees angle to receive a panel of 16 in. (420 mm).
2. Provide with two fastener kits.
H. Elite mesh panels and posts shall be zinc-coated steel wire conforming to specification
ASTM A641 (1989) Class 1, and with 4 mils polyester powder coating as specified below.
A. Height:
1. 4 feet (1230 mm).
2. 6 feet (1830 mm).
3. 8 feet (2430 mm).
4. Multiple stacked panels as shown on the Drawings.
32 31 00 -7
2. The wires are welded by resistance weld at each crossing to form rectangles 1-15/16
x 7-7/8 inches (50 x 200mm).
3. The cold rolled wire shall have a tensile strength of at least 75,000 psi (515 Mpa) and
a 3150 lbs (1430 Kg) break strength for an individual wire.
4. One end of the vertical wires of the panel shall exceed 1 inch (25 mm) from the last or
first horizontal wire creating a spiked top or bottom depending on the position when
installed. The other end is cut flush.
C. Evolution steel mesh panels are welded at each intersection into a solid one-piece mesh
sheet. Mesh panels are hot dipped galvanized in conformity with ASTM A123/A123M
(GAW).
E. Special Panel Fittings (SPF): Hot dipped galvanized steel enable panels to be fastened to
any vertical or horizontal surface, such as steel or concrete beams or wood posts. Provide
the following model:
1. SPF-W Kit: For mounting on a vertical surface, consisting of an L-shaped slotted
plate, which accommodates a 1-3/4'' (45 mm) vertical adjustment and a retaining plate
that hold two vertical wires when bolted together.
2. SPF-C Kit: for horizontal surfaces, uses the same "L" shaped slotted plate and 2 wire
retaining plates.
3. SPF-P Kit: connects two panels together.
F. Chain Link Fence Fittings: to ASTM F 626. All ferrous metal fittings shall be galvanized.
G. Tie Wire or twist ties may be used or added if required. Minimum 9 gauge, 0.148 inch (3.76
mm) galvanized steel or aluminum for attachment of panels to posts.
H. Stretcher bands: fabric bands and brace bands shall be galvanized pressed steel.
32 31 00 -8
1. Aluminum alloy.
2. Galvanized steel.
A. Height:
1. 4 feet (1230 mm).
2. 6 feet (1830 mm).
3. 8 feet (2430 mm).
4. Multiple stacked panels as shown on the Drawings.
32 31 00 -9
of 0.225 inch (5.72 mm) placed between two horizontal wires of 0.303 inch (7.70 mm),
as per ASTM A185 and A853.
2. The wires are welded by resistance weld at each crossing to form rectangles 1-15/16
x 7-7/8 inches (50 x 200mm).
3. The cold rolled wire shall have a tensile strength of at least 75,000 psi (515 Mpa) and
a 3150 lbs (1430 Kg) break strength for the 0.225 inch (5.72 mm) wires and of 5600
lbs (2545 Kg) for the 0.303 inch (7.70 mm) wires.
4. One end of the vertical wires of the panel shall exceed 1 inch (25 mm) from the last or
first horizontal wire creating a spiked top or bottom depending on the position when
installed. The other end is cut flush.
5. Panel camber may not exceed 0.094inch (2.5 mm).
C. Square Posts: Cold rolled 1008 grade steel to meet ASTM 500 and ASTM A787 and the
following maximum horizontal loads, length as required for installation type:
1. Installation: In ground, post length as required for local frost line requirements.
2. Installation: Surface mounted, flanged.
3. Post Size: 2 x 2 inch (50 x 50 mm):
a. 16 gauge (1.6 mm), 329 pound (149 kg) maximum horizontal load.
b. 11 gauge (3.0 mm), 578 pound (262 kg) maximum horizontal load.
4. Post Size: 3 x 3 inch (75 x 75 mm):
a. 11 gauge (3.0 mm), 1383 pound (627 kg) maximum horizontal load.
5. Post Size: 2 x 2 inch (50 x 50 mm):
a. 16 gauge (1.6 mm), 263 pound (119 kg) maximum horizontal load.
b. 11 gauge (3.0 mm), 463 pound (210 kg) maximum horizontal load.
6. Post Size: 3 x 3 inch (75 x 75 mm):
a. 11 gauge (3.0 mm), 1106 pound (501 kg) maximum horizontal load.
7. Post Size: 2 x 2 inch (50 x 50 mm):
a. 11 gauge (3.0 mm), 385 pound (175 kg) maximum horizontal load.
8. Post Size: 3 x 3 inch (75 x 75 mm):
a. 11 gauge (3.0 mm), 922 pound (418 kg) maximum horizontal load.
9. Post Size: 2 x 2 inch (50 x 50 mm):
a. 11 gauge (3.0 mm), 289 pound (131 kg) maximum horizontal load.
10. Post Size: 3 x 3 inch (75 x 75 mm):
a. 11 gauge (3.0 mm), 691 pound (313 kg) maximum horizontal load.
D. Post Brackets:
1. Universal Post Bracket Kit, Includes the following: 13 gauge (2.4mm) steel collar, nut,
washer and carriage bolt 1/4 x 1-1/4 inch (6.4 x 32 mm), all galvanized steel.
a. For 90 degrees turns, use the same bracket.
b. For different angles, used universal angle brackets.
c. For 4 foot (1230 mm) high panels: Provide 4 brackets per panel.
d. For 5 foot (1449 mm) high panels: Provide 6 brackets per panel.
e. For 6 foot (1830 mm) high panels: Provide 6 brackets per panel.
f. For 8 foot (2430 mm) high panels: Provide 8 brackets per panel.
2. U-Shaped Bracket Kit, Includes the following: Stainless steel U rod 5/16 inch (8 mm)
diameter, rear flange in PVC 3-1/2' x 1-1/2' x 1-1/8 inches (88.7 x 37.8 x 28.4 mm),
forehead support in PVC 2-3/8' x 5/8' x 1-1/16 (60.4 x 15.2 x 27.5 mm) cosmetic
plastic caps and nuts (M8).
a. For 4 foot (1230 mm) high panels: Provide 4 brackets per panel.
b. For 4 foot (1230 mm) high panels: Provide 6 brackets per panel.
c. For 5 foot (1449 mm) high panels: Provide 6 brackets per panel.
d. For 6 foot (1830 mm) high panels: Provide 6 brackets per panel.
e. For 8 foot (2430 mm) high panels: Provide 8 brackets per panel.
E. Special Panel Fittings (SPF): Hot dipped galvanized steel enable panels to be fastened to
any vertical or horizontal surface, such as steel or concrete beams or wood posts. Provide
32 31 00 -10
the following model:
1. SPF-W Kit: For mounting on a vertical surface, consisting of an L-shaped slotted
plate, which accommodates a 1-3/4'' (45 mm) vertical adjustment and a retaining plate
that hold two vertical wires when bolted together.
2. SPF-C Kit: for horizontal surfaces, uses the same "L" shaped slotted plate and 2 wire
retaining plates.
3. SPF-P Kit: connects two panels together.
F. Post Caps:
1. Aluminum alloy.
2. Galvanized steel.
G. Overhang Extension:
1. Same dimensions as the post, minimum 18 in. (460 mm) long, welded to the end
square posts to form a 45 degrees angle to receive a panel of 16 in. (420 mm).
2. Provide with two fastener kits.
H. Secur mesh panels and posts shall be zinc-coated steel wire conforming to specification
ASTM A641 (1989) Class 1, and with 4 mils polyester powder coating as specified below.
A. Height:
1. 4 feet (1289 mm).
2. 6 feet (1889 mm).
D. Harmony mesh panels and posts shall be zinc-coated steel wire conforming to specification
ASTM A641 (1989) Class 1, and with 4 mils polyester powder coating as specified below.
32 31 00 -11
2.7 OMEGA II ECO FENCES
A. Height:
1. 4 feet (1245 mm).
2. 5 feet (1549 mm).
3. 6 feet (1778 mm).
4. 8 feet (2464 mm).
5. Multiple stacked panels.
C. Square Posts: Cold rolled 1008 grade steel to meet ASTM 500 and ASTM A787 and the
following maximum horizontal loads, length as required for installation type:
1. Installation: In ground, post length as required for local frost line requirements.
2. Installation: Surface mounted, flanged.
3. Post Size: 2 x 2 inch (50 x 50 mm):
a. 16 gauge (1.6 mm), 329 pound (149 kg) maximum horizontal load.
b. 11 gauge (3.0 mm), 578 pound (262 kg) maximum horizontal load.
4. Post Size: 3 x 3 inch (75 x 75 mm):
a. 11 gauge (3.0 mm), 1383 pound (627 kg) maximum horizontal load.
5. Post Size: 2 x 2 inch (50 x 50 mm):
a. 16 gauge (1.6 mm), 263 pound (119 kg) maximum horizontal load.
b. 11 gauge (3.0 mm), 463 pound (210 kg) maximum horizontal load.
6. Post Size: 3 x 3 inch (75 x 75 mm):
a. 11 gauge (3.0 mm), 1106 pound (501 kg) maximum horizontal load.
7. Post Size: 2 x 2 inch (50 x 50 mm):
a. 11 gauge (3.0 mm), 385 pound (175 kg) maximum horizontal load.
8. Post Size: 3 x 3 inch (75 x 75 mm):
a. 11 gauge (3.0 mm), 922 pound (418 kg) maximum horizontal load.
9. Post Size: 2 x 2 inch (50 x 50 mm):
a. 11 gauge (3.0 mm), 289 pound (131 kg) maximum horizontal load.
10. Post Size: 3 x 3 inch (75 x 75 mm):
a. 11 gauge (3.0 mm), 691 pound (313 kg) maximum horizontal load.
D. Post Brackets:
1. ECO Post Bracket Kit, Includes the following: 14 gauge (2.6mm) steel collar and wire
retaining plate 1/4 x 1 inch (6.3 x 25 mm), nut, washer and carriage bolt 5/16 x 1-1/4
32 31 00 -12
inch (8.0 x 32 mm), all galvanized steel.
a. For 4 foot (1245 mm) high panels: Provide 2 brackets per post.
b. For 5 foot (1549 mm) high panels: Provide 3 brackets per post.
c. For 6 foot (1778 mm) high panels: Provide 3 brackets per post.
d. For 8 foot (2464 mm) high panels: Provide 4 brackets per post.
2. U-Shaped Bracket Kit, Includes the following: Stainless steel U rod 5/16 inch (8 mm)
diameter, rear flange in PVC 3-1/2' x 1-1/2' x 1-1/8 inches (88.7 x 37.8 x 28.4 mm),
forehead support in PVC 2-3/8' x 5/8' x 1-1/16 (60.4 x 15.2 x 27.5 mm) cosmetic
plastic caps and nuts (M8).
E. Special Panel Fittings (SPF): Hot dipped galvanized steel enable panels to be fastened to
any vertical or horizontal surface, such as steel or concrete beams or wood posts. Provide
the following model:
1. SPF-W Kit: For mounting on a vertical surface, consisting of an L-shaped slotted
plate, which accommodates a 1-3/4'' (45 mm) vertical adjustment and a retaining plate
that hold two vertical wires when bolted together.
2. SPF-C Kit: for horizontal surfaces, uses the same "L" shaped slotted plate and 2 wire
retaining plates.
3. SPF-P Kit: connects two panels together.
F. Post Caps:
1. Aluminum alloy.
2. Galvanized steel.
G. Overhang Extension:
1. Same dimensions as the post, minimum 18 in. (460 mm) long, welded to the end
square posts to form a 45 degrees angle to receive a panel of 16 in. (420 mm).
2. Provide with two fastener kits.
H. Eco mesh panels and posts shall be zinc-coated steel wire conforming to specification
ASTM A641 (1989) Class 1, and with 4 mils polyester powder coating as specified below.
A. Height:
1. 47.01 inches (1194 mm).
2. 78.19 inches (1986 mm).
3. 98.98 inches (2514 mm).
4. Multiple stacked panels.
C. Bar Spacing:
1. OMEGA 10: 5.197 inches (132 mm).
2. OMEGA 20: 2.60 inches (66 mm).
32 31 00 -13
8. Steel Bars Breaking Load: 2,166 lb (982.4 kg) per bar.
9. Frame: 2 heat-formed horizontal plates 1 inch (25 mm) wide and 0.16 inch (4.0 mm)
thick to AISI 1008 and ASTM A505.
10. Frame ends are folded at 90 degrees for securing to posts.
11. Folds are 2.56 inch (65 mm) longer than the vertical plates of the fence panel.
12. The difference between the panel width at the top and the width at the bottom shall be
less than 0.25 inch (6.4 mm).
13. Panel diagonals shall not present a difference of more than 0.25 inch per 59.05 inches
(6.4 mm per 1.5 m) panel length.
E. Square Posts: For installation in the ground or on base plates to meet the following
horizontal loading requirements. Secured to posts with 3/8 x 3-1/2 inch (9.5 x 89 mm)
galvanized carriage bolts and 3/8 inch (9.5 mm) galvanized nuts.
1. 2 x 2 inches (50 x 50 mm) 11 gauge (3.0mm) posts:
a. 50 inches (1290 mm) Posts: 502.8 pounds (2442 N).
b. 82 inches (2082 mm) Posts: 339.3 pounds (1513 N).
c. 102 inches (2610 mm) Posts: 270.7 pounds (1207 N).
2. 3 x 3 inches (75 x 75 mm) 11 gauge (3.0mm) posts:
a. 50 inches (1290 mm) Posts: 1309.7 pounds (5840 N).
b. 82 inches (2082 mm) Posts: 811.3 pounds (3618 N).
c. 102 inches (2610 mm) Posts: 647.2 pounds (2886 N).
F. Flat Posts: For installation in the ground or on base plates to meet the following horizontal
loading requirements. Secured to the posts at top of frame and bottom of frame using 3/8 x
1-1/2 inch (9.5 x 38 mm) galvanized carriage bolts and 3/8 inch (9.5 mm) galvanized nuts.
1. 2.36 x 1/4 inch (60 x 6.35 mm) Posts:
a. 50 inches (1274 mm): 241.5 pounds (1077 N).
b. 81 inches (2066 mm): 148.9 pounds (664 N).
c. 102 inches (2594 mm): 118.6 pounds (529 N).
2. 3.15 x 1/4 inch (80 x 6.35 mm) Posts:
a. 50 inches (1274 mm): 429.2 pounds (1077 N).
b. 81 inches (2066 mm): 264.6 pounds (1180 N).
c. 102 inches (2594 mm): 210.8 pounds (940 N).
A. Height:
1. 77.28 inches (1963 mm).
2. Multiple stacked panels.
32 31 00 -14
resistance-welded to louvers.
4. Rectangle Size: 5.20 inch by 1.80 inch (132 mm by 45.77 mm).
5. Cold Rolled Steel Bars: Tensile strength 75,000 psi (515 MPa) and breaking load
1499 lb (680.0 kg) per bar.
6. Panel longitudinal curvature shall not exceed 1/200 of the frame length.
7. Transverse curvature shall be less than or equal to 0.394 in. per 39.37 in. (10 mm per
1 m) of panel length.
8. The difference between the panel width at the top and the width at the bottom shall be
less than 0.25 in. (6.4 mm).
9. Panel diagonals shall not present a difference of more than 0.25 in. (6.4 mm) in
length. Difference between c/c distances of horizontal bars shall not be more than
0.25 in. per 59.05 in. (6.4 mm per 1.5 m) of panel length.
E. Square Posts: For installation in the ground or on base plates to meet the following
horizontal loading requirements. ). Fabricated of 16 gauge or 11 gauge pre-galvanized steel;
cold-formed AISI 1008 steel in compliance with ASTM A500 Grade C and ASTM A787.
1. 2 x 2 inches (50 x 50 mm) 11 gauge (3.0mm) posts:
a. Model 80 - 79.05 (2008 mm), 351.8 pounds (1569 N).
b. Model 100 - 79.53 (2020 mm), 349.8 pounds (1560 N).
2. 3 x 3 inches (75 x 75 mm) 11 gauge (3.0mm) posts:
a. Model 80 - 79.05 (2008 mm), 841.4 pounds (3752 N).
b. Model 100 - 79.53 (2020 mm), 836.3 pounds (3729 N).
F. Flat Posts: For installation in the ground or on base plates to meet the following horizontal
loading requirements. Standard Flat Post thickness is 0.25 in. (6.35 mm). Hot-dip galvanized
in accordance with ASTM A123 G100.
1. 2.36 x 1/4 inch (60 x 6.35 mm) Posts:
a. Model 80 - 78.42 inch (1992 mm), 154.5 pounds (689 N).
b. Model 100 - 78.90 inch (2004 mm), 153.4 pounds (684 N).
2. 3.15 x 1/4 inch (80 x 6.35 mm) Posts:
a. Model 80 - 78.42 inch (1992 mm), 275.5 pounds (1224 N).
b. Model 100 - 78.90 inch (2004 mm), 272.9 pounds (1217 N).
G. Panels: Secured to the posts with vertical plates. Galvanized 3/8 inch diameter X 1-1/2 inch
(9.5 mm x 38 mm) carriage bolts and galvanized 3/8 inch diameter (9.5 mm) nuts are
required to secure panels to flat posts. For 2 inch square posts, install posts using
galvanized 3/8 inch diameter x 3-1/2 inch (9.5 mm x 89 mm) carriage bolts and galvanized
3/8 inch diameter (9.5 mm) nuts. Four attachment points are required.
H. Square Post Caps: Aluminum, 2 inch. x 2 inch (50 mm x 50 mm) or 3 inch x 3 inch (76 mm x
76 mm) depending on chosen post model. Galvanized steel, 4 inch x 4 inch (102 mm x 102
mm) or larger posts.
I. Extensions: If applicable, 45 degree extensions on 2 inch (50 mm) and on 3 inch (76 mm)
square posts, as well as on 2.36 in. x 1/4 inch (60 mm x 6.35 mm) and on 3.15 in. x 1/4 inch.
(80 mm x 6.35 mm) flat posts. The extension length shall be a minimum of 18 inches (460
mm) and shall be welded at the end of the square post at a 45 degree angle. A minimum
fence height of 6 feet (1829 mm) is required to be able to use these extensions.
J. Straight or V-shaped Caps: 14.5 inch (368 mm) long at a 45 degree angle, with provisions to
attach 3 rows of barbed wire at 4 inch (100 mm) intervals, shall be solidly secured to the
posts with self-tapping screws which can withstand a 250 lb (113 kg) load.
32 31 00 -15
2. Vertical Panels (HxW): 8 x 4 ft: 91-3/4 x 44 inches (2330 x 1118 mm).
3. Vertical Panels (HxW): ___ x ___inches (___ x ___ mm).
4. Horizontal panels (HxW): 4 x 6 ft: 43-3/4 x 68 inches (1111 x 1727 mm).
5. Horizontal panels (HxW): 4 x 8 ft: 43-3/4 x 92 inches (1111 x 2337 mm).
6. Horizontal Panels (HxW): ___ x ___inches (___ x ___ mm).
B. Perforated Panels: Aluminum Sheet: 5052-H32; 1/8 inch (3.2 mm) thick.
1. Folds: Typically made on all four sides of the panel, 2 inch (51 mm).
2. Buffer: 1 inch (25 mm) reserved on the circumference of the panel (after folds) before
the beginning of extruding the selected design.
3. Stack two vertical panels to double the fence height.
4. Panels are joined together with hexagonal screws and tamper-proof nuts.
5. Rectangular holes of 1/2 x 3/8 inch (13 x 9.5 mm) are made on panel folded sides to
attach itself to posts or other panels if needed,
C. Square Posts: Cold-formed AISI 1008 steel to meet ASTM A500 and ASTM A787 and the
following maximum horizontal loads, length as required for installation type:
1. Post Length: Minimum 36 inches (914 mm) more than the actual height of fence for in-
ground installation, depending on local land code requirements (frost line).
2. Installation Type: In-ground, post length as required for local frost line requirements.
3. Installation Type: Surface mounted, flanged.
4. Installation: ________.
5. Post Size: 2 x 2 inch (51 x 51 mm) x 11 ga (0.12 inch or 3.0 mm).
6. Post Size: 3 x 3 inch (76.2 x 76.2 mm) x 11 ga (0.12 inch or 3.0 mm).
D. Flat Posts: Cold-rolled per ASTM A500 and ASTM A787. Hot-dip galvanized per ASTM
A123 Grade 100.
1. Flat Post Width: 2-1/2 inch (64 mm) x 1/4 inch (6.4 mm) thick. Theses flat posts are
2. Post Length: Minimum 36 inches (914 mm) more than the actual height of fence for in-
ground installation, depending on local land code requirements (frost line).
3. Installation Type: In-ground, post length as required for local frost line requirements.
4. Installation Type: Surface mounted, flanged.
5. Installation: ________.
E. Post Brackets: Standard bolt system for installation on flat posts with panels in straight line.
1. Carriage Bolts and Tamper Proof Nuts: Stainless steel. 5/16 in (8 mm)
a. Vertical Panels: Bolts per Post: Three.
b. Horizontal Panels: Bolts per Post: Two.
c. Stacked Horizontal Panels: Bolts per Post: Two.2 bolts per post. Three
additional bolts per set of stacked panels.
F. Post Caps:
1. For posts 2 x 2 inch (51 x 51 mm), 3 x 3 inch (76 x 76 mm) and 4 x 4 inch (102 x 102
mm): Aluminum alloy.
2. For Larger Dimensions: Galvanized steel.
32 31 00 -16
H. Concrete: Comply with ACI 301 f.
1. Portland cement complying with ASTM C150 ________.
2. Aggregates: Complying with ASTM C33.
3. Potable Water for ready-mixed concrete complying with ASTM C94.
4. Measure, batch, and mix Project-site-mixed concrete according to ASTM C94.
5. NOTE TO SPECIFIER ** Select barbed wire finish and spacing. Delete if not required.
I. Barbed Wire: double strand steel wire, 12 ga (2.6 mm), twisted line with 4-point barbs.
1. Wire Finish: Zinc coated.
2. Wire Finish: Aluminum coated.
3. Barb Spacing: 3 inches (76 mm) conforming to ASTM A121.
4. Barb Spacing: 5 inches (127 mm) conforming to ASTM A121.
5. Supporting Arms: Pressed steel provisioned for attaching three rows of barbed wire.
Arms are fastened to the posts. Arm Loading: 250 lbs (113 kg) downward pull at
outermost end of arm without failure.
J. "V"Shaped barbed wire supporting arms: Pressed steel arms at both sides, provisioned for
six rows of barbed wire. Arms are fastened to the posts. Arm Loading: 250 lbs (113 kg)
downward pull at outermost end of arm without failure.
L. Overhang: 45 degree extension with same dimensions as the posts; 2 x 2 inches (51 x 51
mm) or 3 x 3 inch (76 x 76 mm) and a minimum length of 18 inches (457 mm).
1. Weld at end of square post by forming an angle of 45 degrees and provided with two
kits of fasteners to receive a panel of 16 inches (420 mm).
A. Configuration:
1. Single swing.
2. Double swing.
3. Swing as shown on the Drawings.
B. Gate Frames: Two horizontal ASTM F900 galvanized square steel tubes, 16 gauge, 1-1/2 x
1-1/2 inch (38 mm X 38 mm), and two vertical tubes 2 x 2 inch (50 x 50 mm) welded at
intersections to create a rigid frame.
C. Gate Frames: Two horizontal ASTM F900 galvanized square steel tubes, 11 gauge, 1-1/2 x
1-1/2 inch (38 mm X 38 mm), two vertical tubes 2 x 2 inch (50 x 50 mm), and 1-1/2 x 1-1/2
inch (38 x 38 mm) supplementary vertical support, welded at intersections to create a rigid
frame.
D. Gate Posts: Cold rolled 1008 grade steel to meet ASTM 500 and ASTM A787, length as
required for installation type:
1. Installation: In ground, post length as required for local frost line requirements.
2. Installation: Surface mounted, flanged.
3. Post Size: 3 x 3 inch (75 x 75 mm).
4. Post Size: 4 x 4 inch (100 x 100 mm).
5. Post Size: 6 x 6 inch (150 x 150 mm).
6. Post Size: Custom engineering by the manufacturer.
E. Gate Hardware: Hinges, Latches, Drop Rods: Hot-dipped galvanized steel to ASTM F900,
sized to assure proper gate operation. Non-moving parts shall be powder-coated.
1. Hinge: Structurally designed by manufacturer to support gates without deformation
during opening and closing.
32 31 00 -17
2. Latch: Clamp-on, self-latching, gravity system.
3. Keyed Lock-Box: LOCINOX with single lever, one side of each gate as shown.
4. Keyed Lock-Box: LOCINOX with double levers, both sides of gates.
5. Additional Hardware for Double Gates:
a. Keeper: Mechanical device with gravity-lock system to fasten each gate leaf in
full open position.
b. Drop Bar: Secures one gate in closed position using stop pipe to engage the
center drop rod.
c. Self-Locking Device: Integral to latch, and with padlock eyes.
A. Construction: 6063-T6 aluminum to ASTM B221, weighing 0.94 lb/ft (1.39 kg/m), fabricated
in accordance with ASTM F1184, Class 2.
1. Members are welded together to form rigid one-piece frames with integral top track.
2. Provide 2 track and wheel assemblies for each gate leaf, comply with manufacturer
instructions for gates larger than 30 feet (9144 mm).
3. Vertical Uprights: 2 x 2 inch (50 x 50 mm) aluminum, welded to gate frames
approximately 8 foot (2440 mm) apart, dividing the frame into equal sections.
4. Gates over 27 feet (8230 mm): Shipped in 2 parts and field spliced with special
attachments provided by manufacturer.
C. Sliding Components:
1. Bracing: Diagonal adjustable length truss rods of 3/8 inch (9.5mm) galvanized steel, in
each panel of gate frames.
2. Top Track: Enclosed, combination one-piece track and rail of aluminum extrusion
weighing 3.72 lb/ft (5.54 kg/m), able to withstand reaction load of 2000 lb (907 kg).
Track does not receive polymer coating.
3. Truck Assembly: Swivel type, zinc die cast, with 4 sealed lubricant ball bearing rollers,
2 inches (50 mm) in diameter by 9/16 inch (14 mm) in width, and 2 side rolling wheels
to ensure truck alignment in track. Mounted on post brackets using 7/8 inch (22 mm)
diameter ball bolts with 1/2 inch (13 mm) shank. Design truck assembly to withstand
same reaction load as track assembly.
4. Gate Hangers, Latches, Brackets, Guide Assemblies, and Stops: Malleable iron or
steel, galvanized after fabrication. Provide positive latch for padlocking. Fittings do not
receive Polymer coating.
5. Bottom Guide Wheel Assemblies: Two 4 inch (100 mm) diameter rubber wheels,
straddling bottom horizontal gate rail, to allow adjustments to maintain gate frame
32 31 00 -18
plumb and in proper alignment. One assembly attached to each guide post. Bottom
guide wheel assemblies do not receive polymer coating.
D. Gate Posts: Square sections of 4 inch (100mm) hot-dipped galvanized steel to ASTM A500,
Grade B with a minimum yield strength of 40,000 psi (275 MPa), weighing 7.04 lb/ft (10.8
kg/m), and with minimum 1.8 oz/sq.ft. (549 g/m2) zinc coating to ASTM F1234. Length of
gate posts minimum 36 inches (914mm) more than the actual height of the fence for
installation in the ground to meet local frost line requirements.
1. Single Slide Gate: 1 latch post and 2 support posts.
2. Double Slide Gates: 1 latch post and 4 support posts for double slide gates.
B. Electrohydraulic Operation: Provide unit designed for mounting as shown on the drawings;
consisting of electric motor, pump, hydraulic actuator to suit gate type, valves.
1. Provide heater to maintain constant temperature, and cold-weather hydraulic fluid;
with hydraulic locking in both directions.
C. Electromechanical Operation: Provide unit designed for mounting as shown on the drawings;
consisting of electric motor and factory-prewired motor controls, starter, speed control
device, chain-drive assembly, brake, clutch or torque limiter, and as follows:
1. Enclosed worm gear reducer, roller chain drive.
2. Enclosed worm gear and chain and sprocket reducers, roller chain drive.
3. V-belt and worm gear reducers, roller chain drive.
4. V-belt and chain and sprocket reducers, roller chain drive.
5. Enclosed worm gear reducer, wheel and rail drive.
D. Operation Cycle Requirements: Design gate operator to operate for not less than the
following duty and cycles per hour. One cycle equals one gate opening plus one gate
closing.
1. Medium Duty: 10 cycles per hour.
2. Heavy Duty: 25 cycles per hour.
32 31 00 -19
3. Peak Duty: 20 cycles per hour at peak periods.
4. Custom: ___ cycles per hour.
5. Custom: ___ cycles per day.
G. Limit Switches: Adjustable switches, interlocked with motor controls and set to automatically
stop gate at fully retracted and fully extended positions.
H. Emergency Release Mechanism: Quick disconnect release of operator drive system of the
following type of mechanism, permitting manual operation if operator fails. Design system so
control circuit power is disconnected during manual operation.
1. Integral fail-safe release, allowing gate to be pushed open without mechanical
devices, keys, cranks, or special knowledge.
2. Mechanical device, key, or crank-activated release.
A. Electric controls separated from gate and motor and drive mechanism, with NEMA ICS 6,
32 31 00 -20
Type 1, NEMA ICS 6, Type 4, or other type of enclosure approved by the local jurisdiction,
for mounting as shown on the drawings, and with space for additional optional equipment.:
D. Card Readers: Functions only when authorized card is presented. Provide insertion-reader-
type, face-lighted unit fully visible at night and the following:
1. Magnetically coded, single-code system activated by coded card.
2. Magnetically coded, single-code system activated by coded card and permitting four
different access time periods.
3. Programmable, multiple-code capability permitting validating or voiding of individual
cards.
4. Programmable, multiple-code capability permitting validating or voiding of individual
cards and permitting four different access time periods.
5. Reader Type:
a. Touch plate.
b. Swipe.
c. Insertion.
d. Proximity.
6. Timed anti-passback.
7. Limited time usage.
8. Capable of monitoring and auditing gate activity.
E. Digital Keypad Entry Unit: Functions only when authorized code is entered.
1. Multiple-code capability of not less than 5 possible individual codes.
2. Multiple-code capability of not less than 100 possible individual codes.
3. Multiple-code capability of not less than 500 possible individual codes.
4. Multiple-code capability of not less than 2,500 possible individual codes.
5. Multiple-code capability of not less than 10,000 possible individual codes.
6. Multiple-code capability as indicated.
7. Programmable using 1 to 6 digits.
8. Programmable using 1 to 6 digits and permitting up to four different access time
periods.
9. Face-lighted unit with metal-keyed keypad fully visible at night
10. Face-lighted unit with keyless-membrane keypad fully visible at night.
11. Timed anti-passback.
12. Limited time usage.
13. Capable of monitoring and auditing gate activity.
32 31 00 -21
5. Provide number of transmitters as recommended by the manufacturer for each
condition.
6. Provide programmable transmitter with multiple-code capability permitting validating
or voiding of not less than the following codes per channel:
a. 1000 codes per channel.
b. 10,000 codes per channel.
7. Button Transmitters:
a. Single-button-operated control station with open and close functions.
b. Three-button-operated control station with open, close, and stop positions.
c. Three-button-operated control station with open, close, and stop positions, and
with key switch to lock out open and close buttons. Minimum two-keys per
station.
d. Provide independent channels and settings to control various receiver and gate
combinations as indicated.
H. Vehicle Loop Detector System: Automatic closing timer with adjustable time delay before
closing, electronic loop detector with detection patterns adjustable sensitivity and frequency
settings, and panel indicator light designed to detect presence or transit of a vehicle over an
embedded loop of wire and to emit a signal activating the gate operator. Provide number of
loops consisting of multiple strands of wire, number of turns, loop size, and method of
placement at location shown on Drawings, as recommended in writing by detection system
manufacturer for function indicated. Provide with the following:
1. Timer cut-off switch.
2. Operation:
a. Designed to open and close gate.
b. Designed hold gate open until traffic clears.
c. Designed to reverse gate.
3. Loop:
a. Wire in size indicated for field assembly, and sealant.
b. Factory preformed in size indicated.
c. Installation Style:
d. Pave-over.
e. Saw-cut.
I. Vehicle Presence Detector: System with automatic closing timer and adjustable time delay
before closing and presence detector, adjustable detection pattern and sensitivity zones,
designed to detect the presence or transit of a vehicle in gate pathway by interrupting an
infrared beam in zone pattern to emit a signal activating the gate operator, and the following:
1. Timer cut-off switch.
2. Operation:
a. Designed to open and close gate.
b. Designed hold gate open until traffic clears.
c. Designed to reverse gate.
3. Detector Type:
a. Retroreflective
b. Emitter/receiver.
32 31 00 -22
J. Obstruction Detection Devices: Provide each motorized gate with automatic safety sensors
that cause operator to immediately function as follows:
1. Action: Reverse gate in both opening and closing cycles and hold until clear of
obstruction.
2. Action: Stop gate in opening cycle and reverse gate in closing cycle and hold until
clear of obstruction.
3. Internal Sensor: Built-in torque or current monitor senses gate is obstructed.
4. Sensor Edge: Contact-pressure-sensitive safety edge, profile, and sensitivity designed
for type of gate and component indicated, in locations as follows. Connected to control
circuit using the following:
a. Take-up cable reel.
b. Self-coiling cable.
c. Gate edge transmitter and operator receiver system.
d. Sensor edge location:
1) Along entire gate leaf leading edge.
2) Along entire gate leaf trailing edge.
3) Across entire gate leaf bottom edge.
4) Along entire length of gate posts.
5) Along entire length of gate guide posts.
6) Where indicated on Drawings.
5. Photoelectric/Infrared Sensor System: Designed to detect an obstruction in partition's
path by interruption of an infrared beam in the zone pattern without obstruction
contacting gate.
2.15 ACCESSORIES
A. Concrete Footing Mixture for In-Ground Installations: Unless otherwise specified in Division
03 Concrete, provide the following:
1. Normal-weight concrete with not less than 3000 psi (20.7- Mpa) compressive strength
(28 days);
2. 3 inch (75-mm) slump and containing coarse aggregate of minimum diameter of 0.2
inches (5 mm) to maximum of 3/4 inch (20 mm);
3. 5% to 7% air entrainment.
D. Barbed Wire:
1. Supporting Arms: Pressed steel arms attached to post support 3 rows of barbed wire.
Arms withstand 250 lb. (113 kg) downward pull at outermost end of arm without
failure.
2. Barbed Wire: Zinc or aluminum coated steel wire to ASTM A121, double strand, 12
gauge, twisted line wire with 4 point barbs, spaced approximately 3 inches (75 mm)
on center.
3. Barbed Wire: Zinc or aluminum coated steel wire to ASTM A121, double strand, 12
gauge, twisted line wire with 4 point barbs, spaced approximately 5 inches (125 mm)
on center.
32 31 00 -23
F. Audio Warning Module: ADA-compliant audible alarm sounding three to five seconds in
advance of gate operation and continuing until gate stops moving.
G. Visual Warning Module: ADA-compliant visible alarm sounding three to five seconds in
advance of gate operation and continuing until gate stops moving.
1. Alarm Light Type: Constant.
2. Alarm Light Type: Strobe.
H. Battery Backup System: Battery-powered drive and access control system, independent of
primary drive system, opening gate if power fails.
I. External electric-powered lock with delay timer allowing time for lock to release before gate
operates. Provide with:
1. Solenoid for swing gate.
2. Magnetic for swing gate.
3. Solenoid for slide gate.
4. Magnetic for slide gate.
N. Intercom system.
2.16 FINISHES
A. Zinc Coating:
1. Wire Mesh Coating: 0.5 oz./sq.ft. (150 g/m2) zinc in conformity with ASTM A 641
(1989) Class 1.
2. Fence Posts and Gate Frames Coating: Zinc coated (galvalume process) with a
minimum of 0.9 oz/sq.ft. (275 g/m2) as per ASTM A653 G90.
32 31 00 -24
6. Gloss Coating: Chocolate brown, RAL 8017.
7. Gloss Coating: Signal red, RAL 3001.
8. Textured Coating: Signal yellow, RAL 1003.
9. Textured Coating: Taupe brown.
10. Textured Coating: Sapphire blue, RAL 5003.
11. Metallic Coating: Silver.
12. Metallic Coating: Silver vein.
13. Metallic Coating: Copper vein.
14. Custom Coating: [_______] [Match RAL _____].
PART 3 EXECUTION
3.1 EXAMINATION
A. Examine areas and conditions, with Installer present, for compliance with requirements for
site clearing, earthwork, pavement work, and other conditions affecting performance.
1. Do not begin installation before final grading is completed, unless otherwise permitted
by Architect.
2. Provide a verified survey of property lines and legal boundaries.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 PREPARATION
A. Stake locations of fence lines, gates, and terminal posts. Do not exceed intervals of 500 feet
(152.5 m) or line of sight between stakes.
B. Terminal Posts Layout: Locate terminal end, corner, and gate posts at changes in horizontal
or vertical alignment of:
1. 15 degrees or more.
2. 30 degrees or more.
3. As indicated on Drawings.
4. __________________
32 31 00 -25
plus or minus 1-1/2 in. (38 mm).
3. ECO Architectural panel 95-9/16 inch (2427 mm) center to center with an adjustment
of plus or minus 1-1/2 in. (38 mm).
4. OMEGA 10-20 panels fence 81-3/4 inch (2076 mm) center to center with a adjustment
of plus or minus 5/16 in. (8 mm).
5. OMEGA 80-100 panels 68 inch (1726 mm) center to center with an adjustment of plus
or minus 5/16 in. (8 mm).
E. For Evolution panel installation; Space line posts equal distant 10 feet (3050 mm) maximum
center to center.
F. For Evolution panel installation; Space line posts equal distance 8 feet (2430 mm) maximum
center to center.
G. Sloped Fences:
1. Step fence sections in accordance with the manufacturer's instructions.
2. Unless otherwise shown on the drawings, align a new post at each step for a clean
line.
3. Slide universal brackets on posts to desired height, always installing flush with
horizontal wire (no gap).
4. For steep slopes, provide longer posts and panels cut in half or panels in special
shapes to keep gaps under panels to a minimum.
A. Drill or hand-excavate holes for posts to spacing indicated, in firm, undisturbed or compacted
soil.
B. Dig holes with a diameter 4 times the diameter of the post and 6 inches (150 mm) deeper
than the bottom of the post.
1. Minimum 8 inch (200 mm) in diameter and 42 inch (1070 mm) in depth.
C. Concrete forms are not necessary or recommended. Crown concrete at top to shed water.
D. Measure, batch, and mix project-site-mixed concrete according to ASTM C 94. Pour
concrete and let cure in accordance with ACI 301 and Division 03 Section "Cast-in-Place
Concrete".
E. Exposed Concrete Footings: Extend concrete 2 inches (50 mm) above grade, or as indicated
on Drawings, smooth, and shape to shed water.
F. Concealed Concrete Footings: Stop footings 2 inches (50 mm) below grade or as indicated
on Drawings to allow covering with surface material.
G. Post Setting: Set posts in concrete footing. Protect portion of posts above ground from
concrete splatter. Place concrete around posts and consolidation. Using mechanical devices
to set posts is not permitted. Verify that posts are set plumb, aligned, and at correct height
and spacing, and hold in position during placement and finishing operations until concrete is
sufficiently cured.
H. Posts Set into Concrete in Sleeves: Use steel pipe sleeves preset and anchored into
concrete for installing posts. After posts have been inserted into sleeves, fill annular space
between post and sleeve with non-shrink, non-metallic grout, or anchoring cement, mixed
and placed to comply with anchoring material manufacturer's written instructions, and
finished sloped to drain water away from post.
I. Posts Set into Concrete in Voids: Form or core drill holes not less than 5 inches (125 mm)
deep and 3/4 inch (20 mm) larger than outside diameter of post. Clean holes of loose
32 31 00 -26
material, insert posts, and fill granular space between post and concrete with non-shrink,
non-metallic grout or anchoring cement, mixed and placed to comply with anchoring material
manufacturer's written instructions, and finished sloped to drain water away from post.
A. Flange Post Installation: Bolt mounting plates attached to each post to slab or structure as
indicated, using expansion bolts in accordance with the manufacturer's instructions.
A. Once the post installation is complete, install the mesh sections with the Universal Bracket
kits, flush with horizontal wire of the panel (no gap).
B. Attach the panels to the posts with eye-U-bracket and tie wire or twist tie. Where two panels
meet and no post is set, join them with end-to-end connectors used for panel to panel
linkage. Do not exceed manufacturers recommended spacing. Attach panel to corner posts
with bands spaced maximum of 24 inches (2610 mm) on center.
C. Panel Installation: Installed a minimum of 1-1/4 inch (30 mm) and maximum of 2 inches (50
mm) above the ground surface.
1. Install vertical wire extensions pointing up for security.
2. Install vertical wire extensions pointing down for safety.
D. Upon cutting or trimming, a post or a wire mesh section, apply a zinc rich primer to the
exposed ends and finish with matching touch-up paint supplied by the manufacturer.
E. Barbed wire: Uniformly space parallel rows of barbed wire on security side of fence. Pull wire
taut and attach to each extension arm. The extension armed is fastened to the post.
A. General: Install gate operators according to manufacturer's written instructions, aligned and
true to fence line and grade.
B. Excavation for Supports: Hand-excavate holes for bases, in firm, undisturbed or compacted
soil to dimensions and depths and at locations as required by gate operator component
manufacturer's written instructions and as indicated on Drawings.
C. Concrete Bases: Cast-in-place or precast concrete, made of not less than 3000 psi (20.7-
Mpa) compressive strength (28 days), depth not less than 12 inches (300 mm) below frost
line or detail on Drawings, dimensioned and reinforced according to gate operator
component manufacturer's written instructions and as indicated on Drawings.
32 31 00 -27
depths at least 6 inches (150 mm) deeper than frost level.
3. Set post bottom 36 inches (914 mm) below surface when in firm, undisturbed soil.
4. Excavate and set posts deeper where required for adequate support in soft and loose
soils, and for posts with heavy lateral loads.
5. Place concrete around posts in a continuous pour, tamp for consolidation.
6. Trowel finish around gate posts and slope to direct water away.
7. Check each post for vertical and top alignment, and maintain in position during
placement and finishing operations.
C. Install gates perfectly horizontal and levelled (at junction), plumb, and secure for full opening
without interference.
D. Attach hardware with nuts inside the property making the assembly tamper-proof to prevent
unauthorized removal. Install ground-set items in concrete for anchorage.
E. Adjust hardware for smooth operation and lubricate where necessary to operate smoothly,
easily, and quietly, free from binding, warp, excessive deflection, distortion, nonalignment,
misplacement, disruption, or malfunction, throughout entire operational range. Confirm that
latches and locks engage accurately and securely without forcing or binding.
C. Fences within 100 feet (30 m) of Buildings, Structures, Walkways, and Roadways: Ground at
maximum intervals of 750 feet (225 m).
D. Gates and Other Fence Openings: Ground fence on each side of opening.
1. Bond metal gates to gate posts.
2. Bond across openings, with and without gates, except openings indicated as
intentional fence discontinuities.
3. Use No. 2 AWG wire and bury it at least 18 inches (460 mm) below finished grade.
E. Conductors: Bare, solid wire for No. 6 AWG and smaller; stranded wire for No. 4 AWG and
larger.
I. 3 Bonding Jumpers: Braided copper tape, 1 inch (25 mm) wide, woven of No. 30 AWG bare
copper wire, terminated with copper ferrules.
L. Ground Rods: Copper-clad steel, sized 5/8 x 96 inches (16 by 2400 mm).
N. Fences Enclosing Electrical Power Distribution Equipment: Ground as required by IEEE C2,
32 31 00 -28
unless otherwise indicated.
O. Grounding Method: At each grounding location, drive a ground rod vertically until the top is 6
in. (150 mm) below finished grade. Connect rod to fence with No. 6 AWG conductor.
Connect conductor to each fence component at the grounding location.
P. Bonding Method for Gates: Connect bonding jumper between gate post and gate frame.
F. Report: Prepare test reports, certified by testing agency, of ground resistance at each test
location. Include observations of weather and other phenomena that may affect test results.
A. Gate: Adjust gate to operate smoothly, easily, and quietly, free from binding, warp, excessive
deflection, distortion, nonalignment, misplacement, disruption, or malfunction, throughout
entire operational range. Confirm that latches and locks engage accurately and securely
without forcing or binding.
B. Automatic Gate Operator: Energize circuits to electrical equipment and devices. Adjust
operators, controls, safety devices, alarms, and limit switches.
1. Electrohydraulic Operator: Purge operating system, adjust pressure and fluid levels,
32 31 00 -29
and check for leaks.
2. Operational Test: After electrical circuitry has been energized, start units to confirm
proper motor rotation and unit operation. Perform tests to confirm that operation
meets desired function. Remove damaged and malfunctioning units, replace with new
units, and retest.
3.13 PROTECTION
END OF SECTION