SL NO.
DESCRIPTION UNIT QTY
1.0 AUTO SYNCHORINIZATION PANEL
Synchoronization Panel capable of sychronizing DX / VRF Indoor Units to Operate
based on the set number of hours, switch ON / OFF in the event of rise in
temperature, failure of equipment, schedule change-over. The panel shall be
installed in the existing BMS room.
The rate quoted shall included the cost of BMS connectivity with RS-485 port. Lots 3
2.0 DUCT MOUNTED RECTANGULAR IN LINE FAN UNIT:
All sheet metal Double Skin Rectangular In Line Centrifugal Fans fabricated out of
1 mm thick Galvanized Steel for use as Exhaust/Outside Air Unit. The unit shall be
complete with flanged connection on either side, fixing bracket, fan motor
assembly, power cabling with required plug of around 5 m length from the unit
to power socket provided by other agencies etc.. suitable for operation through
on 220 V, 1 Ph, 50 Hz AC supply. The unit shall be installed as shown in the
drawing.
The noise from Inline Fan shall not exceed 40 dbA
The external static pressure of the fan should not be less than 15 mm for fans up
to 750 lps & 20 mm for fans above 751 lps.
The cost of the Inline Fan should also include DOL Starter and 3-speed step
regulator.
The rate quoted shall include all required accessories to communicate to Building
Management System.
2.1 ILFU - I: 250 CFM Nos.
2.2 ILFU - I: 500 CFM Nos. 2
2.3 ILFU - II: 800 CFM Nos. 2
2.4 ILFU - IV: 1000 CFM Nos.
2.5 ILFU - IV: 1500 CFM Nos. 4
OUTSIDE Fan with pre filter
2.1 ILFU - I: 250 CFM ( with pre filter ) Nos.
2.2 ILFU - I: 500 CFM ( with pre filter ) Nos.
2.3 ILFU - II: 800 CFM ( with pre filter ) Nos.
2.3 ILFU - II: 1000 CFM ( with pre filter ) Nos.
2.4 ILFU - IV: 1500 CFM ( with pre filter ) Nos.
2.5 ILFU - IV: 2000 CFM ( with pre filter ) Nos. 4
Filter for the above fan Nos. 4
3.0 FIRE DAMPERS
3.1 90 minutes Fire damper with shaft extension to suit factory fitted actuator with
400 mm long GSS sleeve with 30 mm TDF flanges. The leakage class shall be
class-1 with 3V blade construction.
The pressure drop across the dampers shall not exceed 1.5 mm of wg at 1500
fpm for the cross section area of 1 sqm.
The rate quoted shall include duct smoke detector, master controller (one for
each AHU room) to control zonal fire dampers based on the inputs from fire Sqm 4
panel, BMS & sensor.
3.2 Spring loaded Actuator of required tarque assembled in factory with required
accessories to operate fire damper, step-down transformer, auxiliary switch,
controller, necessary wiring & mounting arrangement. The actuator shall be
Nos. 20
equipped for 230V AC operation. The actuator shall also operate based on the
input from BMS & pass on the status output to BMS and communicate to BMS
System with an RS 485 port.
4.0 FIRE DAMPER WITH FUSIBLE LINK
4.1 90 minutes, AMCA certified Fire damper with 400 mm long GSS sleeve with 30
mm deep TDF flanges. The leakage class shall be class-1 with 3V blade
construction.
The pressure drop across the dampers shall not exceed 1.5 mm of wg at 1500
Sqm 2
fpm for the cross section area of 1 sqm.
4.2 UL stamped Fusible link with linkage, spring and operating handle Nos. 4
5.0 CAV
Supply ,Installation,testing & commisoning of CAV with nessarry supporting
Sets 104
meaterilas
6.0 AIR TERMINALS
6.1 SUPPLY AIR DIFFUSERS
Powder coated, extruded aluminium, removable centre core type, supply air
diffusers of following neck sizes to be installed in gypsum or grid false ceiling. The
price shall include necessary factory fabricated GI plenum boxes with side entry
collars with required contour (groove) to hold the clamp & flexible duct.
The termination box to be internal lined by acoustic insulation
The noise from the diffuser should not be more than 32 dba.
The diffuser shall be supported at all four corners using chain links.
375 x 375 mm neck size, 595 x 595 mm outer size, Tegular type (up to 400 cfm)
a Nos. 78
and with builtin damper.
450 x 450 mm neck size, 595 x 595 mm outer size, Tegular type (up to 600 cfm)
b Nos.
and with builtin damper.
375 x 375 mm neck size, 595 x 595 mm outer size, Tegular type (up to 300 cfm)
c Nos.
plaque type
450 x 450 mm neck size, 595 x 595 mm outer size, Tegular type (up to 450 cfm)
d Nos.
plaque type
e 300 mm dia Round Diffuser (up to 300 cfm) with collar damper. Nos.
f 400 mm dia Round Diffuser (up to 450 cfm) with collar damper. Nos.
g 295 x 1195 mm outer size, Tegular type (up to 400 cfm) Nos.
h 295 x 595 mm outer size, Tegular type (up to 200 cfm) Nos.
6.2 RETURN AIR DIFFUSERS
Powder coated, extruded aluminium, removable centre core type, return air
diffusers of following neck sizes to be installed in gypsum or grid false ceiling.
The diffuser shall be supported at all four corners using chain links.
375 x 375 mm neck size, 595 x 595 mm outer size, Tegular type (up to 400 cfm)
a Nos. 96
450 x 450 mm neck size, 595 x 595 mm outer size, Tegular type (up to 600 cfm)
b Nos.
375 x 375 mm neck size, 595 x 595 mm outer size, Tegular type (up to 300 cfm)
c Nos.
plaque type
450 x 450 mm neck size, 595 x 595 mm outer size, Tegular type (up to 450 cfm)
d Nos.
plaque type
e 300 mm dia Round Diffuser (up to 300 cfm) Nos.
f 400 mm dia Round Diffuser (up to 450 cfm) Nos.
g 295 x 1195 mm outer size, Tegular type (up to 400 cfm) Nos.
h 295 x 595 mm outer size, Tegular type (up to 200 cfm) Nos.
7.0 GRILLES
7.1 CONTINUOUS GRILLES
Powder coated Extruded aluminium continuous grilles with 25 mm wide & 18
mm deep frame, 5 mm thick blades spaced at a distance of 12.5 mm, the blade
angle shall be as per detail engineering.
The rate quoted shall include the cost of supporting arrangement.
a 150 mm M 120
b 100 mm M
7.2 Return Air Grille
Return Air Grille without coller damper and plenum box to collect return air from
Sqm 2
the space
7.3 AIR TERMINATION BOX FOR CONTINUOUS GRILLE
Air temination box fabricated out of 0.63 mm thick galvanized sheet with comb
type collar damper to ensure zero leak at all four sides of box & grille
termination.
The Supply Air Termination Box shall be acoustically treated with 6 mm thick
class 'O' open cell nitrile rubber.
The noise from the grille should not be more than 32 dba.
The termination box shall be supported at all four corners using chain links. (the
Sqm. 4
area furnished is cross section area of grille)
7.4 CURVED GRILLES
Curved Grilles suitable for fixing in Sprial ducts, the grille surface radius shall be
as per duct radius.
The rate quoted shall includes the cost of splitters (guide veins), dampers etc.,
Sqm.
7.5 DISCRETE GRILLE
Powder coated Extruded aluminium Discrete grilles with 25 mm wide & 18 mm
deep frame on all four sides, 5 mm thick blades spaced at a distance of 12.5 mm,
the blade angle shall be as per detail engineering. The price shall include
necessary Shoe tapping, multiple guide vanes, collar damper with blade
adjustable from face of the grille.
The noise from the grille should not be more than 32 dba. Sqm. 2
8.0 JET DIFFUSER
Powder coated, extruded aluminium, Jet diffuser suitable for air flow rate max. of
600 CFM as mentioned in the drawing and the throw will be at around 8 m. The
diffuser shall be with extruded aluminium Volume Control Damper [Eye ball type]
300 mm dia neck size Nos. 10
9.0 EXTERNAL WALL LOUVERS
Extruded aluminium aerofoil blade rain protection louvers to be installed on
external wall opening as shown in the drawing on the roof for OA intake & Sqm. 2
exhaust.
10.0 INSULATION & ACOUSTICS
10.1 DUCT INSULATION
Thermal insulation for duct insulation using non-fibrous, CFC free, closed cell,
elostomeric nitrile rubber foamed insulation in pre-formed sheets with thermal
conductivity of not more than 0.035 W/(m.k) at 0°C. Class 1 fire rated, high
resistant to water absorption. The material used shall be in rolls. The insulation
sheet joints shall be sealed using self adhesive black tapes of 3 mm thick & 50
mm width.
The contractor should clean the surface of the duct before laying the Thermal
Insulation.
The adhesive & the black tape to be supplied by the insulation manufacturer
only.
The adhesive shall be with low VOC contents & Class 'O' fire rated.
The adhesive to be supplied by the acoustic manufacturer only.
The adhesive shall be with low VOC contents & Class 'O' fire rated.
a 25 mm thick insulation Sqm.
b 20 mm thick insulation Sqm. 400
c 10 / 12 mm thick insulation Lining Sqm. 430
d Mechanical protection by heavy duty and ultra tough multi-layered composite Sqm.
aluminium foil with puncture resistance of >400N as per ASTM D4833
e Glass cloth of approved color supplied by insullation manufacture Sqm.
10.2 ACOUSTIC LINING FOR DUCTS
Acoustic Lining for ducting using non-fibrous, CFC free, open cell, elostomeric
nitrile rubber foamed insulation in pre-formed sheets with Class 1 fire rated,
high resistant to water absorption. The material used shall be in rolls. The
acoustic lining shall be sticked to the inner surface ofthe duct and revetted at
regular interval of not more than 200 mm.
The contractor should clean the surface of the duct before sticking the Acoustic
Lining.
The adhesive to be supplied by the acoustic manufacturer only.
The adhesive shall be with low VOC contents & Class 'O' fire rated.
a 10 mm thick Acoustic Lining Sqm. 120
11.0 DUCT MOUNTED RECTANGULAR IN LINE FAN UNIT:
All sheet metal Double Skin Rectangular In Line Centrifugal Fans fabricated out of
1 mm thick Galvanized Steel for use as Exhaust/Outside Air Unit. The unit shall be
complete with flanged connection on either side, fixing bracket, fan motor
assembly, power cabling with required plug of around 5 m length from the unit
to power socket provided by other agencies etc.. suitable for operation through
on 220 V, 1 Ph, 50 Hz AC supply. The unit shall be installed as shown in the
drawing.
The noise from Inline Fan shall not exceed 40 dbA
The external static pressure of the fan should not be less than 15 mm for fans up
to 750 lps & 20 mm for fans above 751 lps.
The cost of the Inline Fan should also include DOL Starter and 3-speed step
regulator.
The rate quoted shall include all required accessories to communicate to Building
Management System.
a ILFU - I: 250 CFM Nos. 2
b ILFU - II: 500 CFM Nos. 2
c ILFU - III: 1000 CFM Nos. 4
d ILFU - IV: 1500 CFM Nos. 2
12.0 DOMESTIC EXHAUST FAN
12.1 150 MM dia'100 cfm domestic exhaust fan with back draught shutter, low noise
wall mounted, easy maintenance suitable for Toilet Exhaust. The rate quoted
Nos. 4
shall also include cabling between the fan and power socket provided adjacent to
the fan by other agencies.
13.0 AIR TERMINALS
13.1 TOILET DISC VALVE
Powder coated, aluminium Exhaust Disc Valve with four piece construction,
rotatable plate to control the air volume, supporting arrangement etc. The price
shall include necessary factory fabricated GI plenum boxes with side entry collars
with required contour (groove) to hold the clamp & flexible duct.
The Disc Valve shall be supported at diaganally opposite two corners using chain
links.
a 150 mm dia, 75 cfm Nos. 116
14.0 ALUMINIUM VOLUME CONTROL DAMPERS
Low leakage Volume Control Dampers with 30 mm deep TDF flanges suitable for
connecting the ducts on both sides, complete with factory - made, aerofoil
design of aluminium interlocking blades, 1.8 mm thick frame, channels for duct
mounting, nylon bushes, vision indicator to indicate percentage of opening. The
VCD shall be suitable to operate through a actuator if required. Whereas, shall be
supplied with a operating knob with provision to lock at required position.
The Volume Control Damer shall be ACMA certified
The pressure drop across the dampers shall not exceed 1.5 mmwg at 1500 fpm
Sqm. 4
for the cross section area of 1 sqm.
TOTAL
Terms and Conditions :
GST @ 18% extra.
Freight Extra @ Actuals (ADP products from Bhiwandi till site).
Payment Terms : 100% Advance.
Delivery : 4-5 weeks.
Validity : 30 Days.
SUPPLY UNIT
MAKE MODEL AMOUNT
RATE
Aircon Control 13850 ₹ 41,550.00
Caryaire RIF-M-200S 12039 ₹ 24,078.00 Considered
acoustic
Caryaire RIF-M-315 14872 ₹ 29,744.00 Insulation
Caryaire CDIF-09-IS 22278 ₹ 89,112.00
Caryaire CDIF-10-IS 25186 ₹ 100,744.00
950 ₹ 3,800.00
Caryaire FSD-A 10874 ₹ 43,496.00
Belimo NF24A-S2 9919 ₹ 198,380.00
Caryaire FLD-S-A 10178 ₹ 20,356.00
Caryaire 494 ₹ 1,976.00
Caryaire AS-704-GNT 1933 ₹ 150,774.00
Caryaire AS-704-GNT 1396 ₹ 134,016.00
Considered
Caryaire GX135 470 ₹ 56,400.00 0.1mm sqmt.
Caryaire GX135 4703 ₹ 9,406.00
Caryaire ASJN804 3015 ₹ 30,150.00
Caryaire IL-337 5648 ₹ 11,296.00
Caryaire RIF-M-200 11209 ₹ 22,418.00
Caryaire RIF-M-200S 12039 ₹ 24,078.00
Caryaire RIF-M-315 14872 ₹ 59,488.00
Caryaire CDIF-09-IS 22278 ₹ 44,556.00
Caryaire CMF-150 3960 ₹ 15,840.00
Caryaire 540 ₹ 62,640.00
Caryaire AU-350 7388 ₹ 29,552.00
₹ 1,203,850.00