Inspection Report

The Used Drill Pipe Inspection Summary Report for Shree International indicates that all 72 lengths of drill pipe inspected are ready for immediate use, classified as Premium. No repairs or downgrades were necessary, and no lengths were found to be restricted or scrap. The inspection was conducted on November 1, 2024, at Kalamboli, with all findings documented and certified by the inspector.

Uploaded by

SAGAR KALE
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
77 views6 pages

Inspection Report

The Used Drill Pipe Inspection Summary Report for Shree International indicates that all 72 lengths of drill pipe inspected are ready for immediate use, classified as Premium. No repairs or downgrades were necessary, and no lengths were found to be restricted or scrap. The inspection was conducted on November 1, 2024, at Kalamboli, with all findings documented and certified by the inspector.

Uploaded by

SAGAR KALE
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

USED DRILL PIPE INSPECTION SUMMARY REPORT

CUSTOMER : SHREE INTERNATIONAL (HVC) REPORT NO : TS/HVC/5-DP/MUM/11-2024/001


RIG : N/A DATE: 01-11-2024
LOCATION : KALAMBOLI JOB NO. : TS/JN/11-2024/535
P.O NO. :

TYPE OF INSPECTION: VISUAL CONNECTION, DIMENSIONAL - 2 , VISUAL TUBE, ULTRA SONIC WALL THICKNESS MEASUREMENT,

MPI SLIP AREA AND UPSET ,OD GAUGING (EMI NOT DONE)

SPECIFICATION: DS 1 CAT 4

TOTAL LENGTHS OD GRADE WEIGHT WALL RANGE TOOL JOINT


72 5.00" S-135 19.5 0.362" II NC 50

SUMMARY OF RESULTS
CLASS QTY

PREMIUM 72 LENGHTS READY TO BE USED IMMEDIATELY

CROOKED SEAL RE-FACED

STRAIGHTENED PIN BOX


- - -

REPAIR - LENGTHS READY TO BE USED AFTER TOOL JOINT REPAIR/ STRAIGHTENING.

CONNECTION HARD BAND WITH CONN. STRAIGHTENING WITH CONN.


ONLY ONLY ID SCALE
PIN BOX PIN +BOX BOX PIN ONLY HBD PIN BOX PIN & BOX
STRAIGHTENING.

CLASS-II - LENGTHS RESTRICTED DRILLING SERVICES

BODY - REASON FOR DOWN GRADING TOOL JOINT OD WEAR T/J CONN. DAMAGE
SLIP WEAR CUTS/ CORR/ PIN PIN &
MASH OTHERS PIN BOX PIN BOX
AREA BODY GOUGES PITTING BOX BOX

CLASS-III LENGTHS RESTRICTED DRILLING SERVICES

BODY - REASON FOR DOWN GRADING TOOL JOINT OD WEAR T/J CONN. DAMAGE
SLIP WEAR CUTS/ CORR/ PIN PIN & OTHERS
MASH OTHERS PIN BOX PIN BOX
AREA BODY GOUGES PITTING BOX BOX

---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----

CLASS -IV LENGTHS SCRAP TOOL JOINT WEAR TOLERANCE

BODY WEAR ID/OD BODY MINIMUM REQUIREMENT


WASHOUT CRACK
(OD/W.T) PITTING MASH TOOL JOINT SHOULDER

---- ---- ---- ---- --- CLASS OD WIDTH

PREMIUM 6 5/16 29/64


CLASS-II 6 3/16 25/64
72 TOTAL LENGTHS INSPECTED

COMMENTS: TOTAL INSP. QTY : 72 NO'S READY TO USE QTY : 72


REPAIR/RE-CUT QTY : NIL CLASS 2 QTY : NIL

SURYA MANI
Customer Signature Inspector
Level II Cert No.:TS/1293/MTLYC-II
Level II Cert Validity.:14-03-2027
This field report is issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, repairer or operator of any warranty, express or implied and Tubestar's liability shall be limited to the acts and
omissions of its employees and subcontractors. Under no Circumstances shall Tubestar be liable for any injury or damage to any person or property occurring by any reason of negligent operation, misuse, of or any defect in material, machinery, equipment or other items other
than by defects in items actually inspected by Tubestar and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed byTubestar and which are covered by this report. this field report and the recommendation contained within it are
based upon the conditions and practices observed and information available to Tubestar personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings on the criteria shown in this report
are intended as guideline only. Tubestar does not accept responsibility for the control or correction of conditions

F OPN 001 TUB COMMON, Rev.05/10.10.2016


DRILL PIPE INSPECTION TALLY SHEET
CUSTOMER : SHREE INTERNATIONAL (HVC) LOCATION : KALAMBOLI RIG : NA REPORT NO : TS/HVC/5.00DP/MUM/11-2024/001
SHEET NO : 01 OF 05 DATE :01-11-2024
PIPE OD PIPE GRADE WEIGHT LBS/FT NOM. WALL THICKNESS THREAD CONNECTION RANGE
5" S-135 19.50 0.362 NC 50 II
CATEGORY
1 2 3 4 5 HDLS
SPECIFICATION : API RP 7G-2 DS1 STD. X NS - 2 CUST. / SPECIAL
All Dimensions Are In Inches
ID BOX TOOL JOINT PIN TOOL JOINT
ID EMI OD Coating LENGTH OD Remain Final Shoulder Counter Bore Tong Bevel BOX MPI/UT HB Pin PIN Bevel Tong Pin Neck Pin MPI/UT HB
No. Condition Condition MTR Gauge Wall Thick. Class OD Width Dia Depth Space Dia COND. COND. COND. OD ID Diameter Space Length COND. UPSET COND. YOM
SLB 0808 - OK 4 9.305 OK 0.376 P 6 17/32 19/32 5 5/16 21/32 10 6 1/16 OK OK F 6 9/16 3 1/4 6 1/16 7 7/8 3/8 OK OK NIL -
SLB 0833 - OK 4 9.305 OK 0.364 P 6 9/16 5/8 5 5/16 21/32 10 11/16 6 1/16 OK OK F 6 17/32 3 1/4 6 1/16 7 13/16 9/32 OK OK NIL -
SLB 0826 - OK 4 9.635 OK 0.367 P 6 9/16 5/8 5 5/16 21/32 7 5/16 6 1/16 OK OK OK 6 9/16 3 1/4 6 1/16 8 5/16 3/8 OK OK NIL -
SLB 0822 - OK 4 9.645 OK 0.377 P 6 9/16 5/8 5 5/16 21/32 7 3/8 6 1/16 OK OK OK 6 9/16 3 1/4 6 1/16 7 13/16 5/32 OK OK NIL -
SLB 0838 - OK 4 9.649 OK 0.368 P 6 9/16 5/8 5 5/16 21/32 7 3/8 6 1/16 OK OK OK 6 9/16 3 1/4 6 1/16 7 5/16 3/8 OK OK NIL -
SLB 0840 - OK 4 9.637 OK 0.370 P 6 9/16 5/8 5 5/16 21/32 10 13/16 6 1/16 OK OK F 6 9/16 3 1/4 6 1/16 7 11/16 3/8 OK OK NIL -
SLB 0819 - OK 4 9.665 OK 0.371 P 6 9/16 5/8 5 5/16 21/32 11 1/8 6 1/16 OK OK F 6 9/16 3 1/4 6 1/16 6 3/4 1/4 OK OK NIL -
SLB 1055 - OK 4 9.430 OK 0.357 P 6 9/16 5/8 5 5/16 21/32 10 1/2 6 1/16 OK OK F 6 19/32 3 1/4 6 1/16 8 3/8 OK OK NIL -
SLB 0810 - OK 4 9.317 OK 0.367 P 6 17/32 19/32 5 5/16 21/32 10 7/16 6 1/16 OK OK F 6 1/2 3 1/4 6 1/16 7 13/16 3/8 OK OK NIL -
SLB 0801 - OK 4 9.630 OK 0.377 P 6 1/2 19/32 5 5/16 21/32 11 3/32 6 1/16 OK OK F 6 1/2 3 1/4 6 1/16 7 13/16 5/32 OK OK NIL -
SLB 0194 - OK 4 9.635 OK 0.379 P 6 19/32 5/8 5 5/16 21/32 8 6 1/16 OK OK OK 6 9/16 3 1/4 6 1/16 8 1/4 3/8 OK OK NIL -
SLB 0823 - OK 4 9.615 OK 0.375 P 6 17/32 19/32 5 5/16 21/32 10 13/16 6 1/16 OK OK F 6 1/2 3 1/4 6 1/16 7 13/16 3/8 OK OK NIL -
SLB 0791 - OK 4 9.630 OK 0.355 P 6 17/32 19/32 5 5/16 21/32 7 3/8 6 1/16 OK OK OK 6 17/32 3 1/4 6 1/16 7 3/8 OK OK NIL -
SLB 0802 - OK 4 9.631 OK 0.369 P 6 17/32 19/32 5 5/16 21/32 11 1/16 6 1/16 OK OK F 6 17/32 3 1/4 6 1/16 8 1/16 5/16 OK OK NIL -
SLB 0830 - OK 4 9.315 OK 0.361 P 6 17/32 19/32 5 5/16 21/32 10 7/16 6 1/16 OK OK F 6 1/2 3 1/4 6 1/16 7 13/16 1/4 OK OK NIL -
Final Class : P - Premium Class #2 - Class 2 ID Coating Condition : 1 - 100% , 2 - 80% -99% , 3 - 65% - 79% & 4 - Below 65%
DS-Damaged Seal , DT-Damaged Thread , CT-Corroded Thread , WT-Worned Thread, CS-Corroded Seal , GT-Galled Thread , ST-Stretched Thread , EW-Eccentric Wear , WO-Washout , CR-Cracked , HBD-Hard Face Damage & F-H.B FLAT
COMMENTS: ABOVE MENTIONED DRILL PIPE INSPECTED AND FOUND OK AT THTE TIME OF THE INSPECTION.
SURYA MANI
CUSTOMER SIGNATURE Inspector
ASNI Level II Cert No. : TS/1293/MTLYC-II
ASNI Level II Cert Validity :14-03-2027
This field report is issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, repairer or operator of any warranty, express or implied and Tubestar's liability shall be limited to the acts and omissions of its employees and subcontractors. Under no Circumstances shall Tubestar be liable for any injury or damage to any person or
property occurring by any reason of negligent operation, misuse, of or any defect in material, machinery, equipment or other items other than by defects in items actually inspected by Tubestar and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed byTubestar and which are covered by this report. this field report and the recommendation contained within it are
based upon the conditions and practices observed and information available to Tubestar personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings on the criteria shown in this report are intended as guideline only. Tubestar does not accept responsibility for the control or correction of conditions
F OPN 001 TUB DS1, Rev.05/09.10.2016
DRILL PIPE INSPECTION TALLY SHEET
CUSTOMER : SHREE INTERNATIONAL (HVC) LOCATION : KALAMBOLI RIG : NA REPORT NO : TS/HVC/5.00DP/MUM/11-2024/001
SHEET NO : 02 OF 05 DATE :01-11-2024
PIPE OD PIPE GRADE WEIGHT LBS/FT NOM. WALL THICKNESS THREAD CONNECTION RANGE
5" S-135 19.50 0.362 NC 50 II
CATEGORY
1 2 3 4 5 HDLS
SPECIFICATION : API RP 7G-2 DS1 STD. X NS - 2 CUST. / SPECIAL
All Dimensions Are In Inches
ID BOX TOOL JOINT PIN TOOL JOINT
ID EMI OD Coating LENGTH OD Remain Final Shoulder Counter Bore Tong Bevel BOX MPI/UT HB Pin PIN Bevel Tong Pin Neck Pin MPI/UT HB
No. Condition Condition MTR Gauge Wall Thick. Class OD Width Dia Depth Space Dia COND. COND. COND. OD ID Diameter Space Length COND. UPSET COND. YOM
SLB 1060 - OK 4 9.618 OK 0.360 P 6 17/32 19/32 5 5/16 21/32 10 7/8 6 1/16 OK OK F 6 15/32 3 1/4 6 1/16 7 3/4 5/32 OK OK NIL -
SLB 0789 - OK 4 9.635 OK 0.371 P 6 1/2 19/32 5 5/16 21/32 11 3/16 6 1/16 OK OK F 6 9/16 3 1/4 6 1/16 8 3/8 3/8 OK OK NIL -
SLB 0820 - OK 4 9.643 OK 0.374 P 6 9/16 5/8 5 5/16 21/32 11 1/16 6 1/16 OK OK OK 6 9/16 3 1/4 6 1/16 8 5/16 3/8 OK OK NIL -
SLB 1066 - OK 4 9.388 OK 0.368 P 6 9/16 5/8 5 5/16 21/32 6 5/8 6 1/16 OK OK OK 6 9/16 3 1/4 6 1/16 7 5/16 OK OK NIL -
SLB 1064 - OK 4 9.635 OK 0.371 P 6 19/32 5/8 5 5/16 21/32 7 7/8 6 1/16 OK OK OK 6 9/16 3 1/4 6 1/16 7 3/4 5/32 OK OK NIL -
SLB 1054 - OK 4 9.616 OK 0.354 P 6 17/32 19/32 5 5/16 21/32 10 3/8 6 1/16 OK OK F 6 9/16 3 1/4 6 1/16 7 1/16 3/16 OK OK NIL -
SLB 0839 - OK 4 9.394 OK 0.362 P 6 19/32 5/8 5 5/16 21/32 6 13/16 6 1/16 OK OK OK 6 9/16 3 1/4 6 1/16 7 13/16 3/16 OK OK NIL -
SLB 0845 - OK 4 9.637 OK 0.368 P 6 15/32 17/32 5 5/16 21/32 11 1/16 6 1/16 OK OK F 6 17/32 3 1/4 6 1/16 7 13/16 5/32 OK OK NIL -
SLB 0807 - OK 4 9.608 OK 0.312 P 6 19/32 5/8 5 5/16 21/32 7 7/16 6 1/16 OK OK OK 6 9/16 3 1/4 6 1/16 7 7/8 5/16 OK OK NIL -
SLB 0817 - OK 4 9.483 OK 0.312 P 6 9/16 5/8 5 5/16 21/32 10 7/8 6 1/16 OK OK F 6 17/32 3 1/4 6 1/16 8 3/8 7/32 OK OK NIL -
SLB 1061 - OK 3 9.630 OK 0.356 P 6 9/16 5/8 5 5/16 21/32 7 3/8 6 1/16 OK OK OK 6 9/16 3 1/4 6 1/16 7 5/8 9/32 OK OK NIL -
SLB 0818 - OK 4 9.643 OK 0.386 P 6 91/6 5/8 5 5/16 21/32 10 15/16 6 1/16 OK OK F 6 17/32 3 1/4 6 1/16 7 13/16 5/16 OK OK NIL -
SLB 0792 - OK 4 9.626 OK 0.389 P 6 19/32 5/8 5 5/16 21/32 10 6 1/16 OK OK F 6 17/32 3 1/4 6 1/16 7 15/16 5/16 OK OK NIL -
SLB 0824 - OK 4 9.629 OK 0.378 P 6 17/32 19/32 5 5/16 21/32 11 6 1/16 OK OK F 6 17/32 3 1/4 6 1/16 7 3/4 1/4 OK OK NIL -
SLB 0831 - OK 4 9.631 OK 0.386 P 6 9/16 5/8 5 5/16 21/32 11 1/8 6 1/16 OK OK F 6 17/32 3 1/4 6 1/16 7 3/4 9/32 OK OK NIL -
Final Class : P - Premium Class #2 - Class 2 ID Coating Condition : 1 - 100% , 2 - 80% -99% , 3 - 65% - 79% & 4 - Below 65%
DS-Damaged Seal , DT-Damaged Thread , CT-Corroded Thread , WT-Worned Thread, CS-Corroded Seal , GT-Galled Thread , ST-Stretched Thread , EW-Eccentric Wear , WO-Washout , CR-Cracked , HBD-Hard Face Damage & F-H.B FLAT
COMMENTS: ABOVE MENTIONED DRILL PIPE INSPECTED AND FOUND OK AT THTE TIME OF THE INSPECTION.
SURYA MANI
CUSTOMER SIGNATURE Inspector
ASNI Level II Cert No. : TS/1293/MTLYC-II
ASNI Level II Cert Validity :14-03-2027
This field report is issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, repairer or operator of any warranty, express or implied and Tubestar's liability shall be limited to the acts and omissions of its employees and subcontractors. Under no Circumstances shall Tubestar be liable for any injury or damage to any person or
property occurring by any reason of negligent operation, misuse, of or any defect in material, machinery, equipment or other items other than by defects in items actually inspected by Tubestar and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed byTubestar and which are covered by this report. this field report and the recommendation contained within it are
based upon the conditions and practices observed and information available to Tubestar personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings on the criteria shown in this report are intended as guideline only. Tubestar does not accept responsibility for the control or correction of conditions
F OPN 001 TUB DS1, Rev.05/09.10.2016
DRILL PIPE INSPECTION TALLY SHEET
CUSTOMER : SHREE INTERNATIONAL (HVC) LOCATION : KALAMBOLI RIG : NA REPORT NO : TS/HVC/5.00DP/MUM/11-2024/001
SHEET NO : 03 OF 05 DATE :01-11-2024
PIPE OD PIPE GRADE WEIGHT LBS/FT NOM. WALL THICKNESS THREAD CONNECTION RANGE
5" S-135 19.50 0.362 NC 50 II
CATEGORY
1 2 3 4 5 HDLS
SPECIFICATION : API RP 7G-2 DS1 STD. X NS - 2 CUST. / SPECIAL
All Dimensions Are In Inches
ID BOX TOOL JOINT PIN TOOL JOINT
ID EMI OD Coating LENGTH OD Remain Final Shoulder Counter Bore Tong Bevel BOX MPI/UT HB Pin PIN Bevel Tong Pin Neck Pin MPI/UT HB
No. Condition Condition MTR Gauge Wall Thick. Class OD Width Dia Depth Space Dia COND. COND. COND. OD ID Diameter Space Length COND. UPSET COND. YOM
SLB 0825 - OK 4 9.640 OK 0.369 P 6 9/16 5/8 5 5/16 21/32 10 11/16 6 1/16 OK OK F 6 9/16 3 1/4 6 1/16 7 3/4 5/32 OK OK NIL -
SLB 0835 - OK 4 9.598 OK 0.371 P 6 9/16 5/8 5 5/16 21/32 10 3/16 6 1/16 ok OK F 6 19/32 3 1/4 6 1/16 7 13/16 1/4 OK OK NIL -
SDI 152405 - OK 4 9.650 OK 0.346 P 6 17/32 19/32 5 5/16 21/32 9 15/16 6 1/16 OK OK F 6 19/32 3 1/4 6 1/16 7 11/16 5/32 OK OK NIL -
SLB 0795 - OK 4 9.660 OK 0.356 P 6 9/16 5/8 5 5/16 21/32 7 3/8 6 1/16 OK OK OK 6 9/16 3 1/4 6 1/16 7 11/16 5/16 OK OK NIL -
SLB 0832 - OK 4 9.645 OK 0.369 P 6 9/16 5/8 5 5/16 21/32 11 1/8 6 1/16 OK OK F 6 17/32 3 1/4 6 1/16 7 7/8 5/32 OK OK NIL -
SLB 1059 - OK 4 9.636 OK 0.364 P 6 17/32 9/16 5 5/16 21/32 7 5/16 6 1/16 OK OK OK 6 9/16 3 1/4 6 1/16 7 7/8 3/8 OK OK NIL -
SLB 1062 - OK 4 9.434 OK 0.355 P 6 9/16 5/8 5 5/16 21/32 11 1/16 6 1/16 OK OK F 6 17/32 3 1/4 6 1/16 7 15/16 5/16 OK OK NIL -
SLB 0799 - OK 4 9.609 OK 0.368 P 6 17/32 9/16 5 5/16 21/32 7 3/16 6 1/16 OK OK OK 6 9/16 3 1/4 6 1/16 7 9/16 5/32 OK OK NIL -
SLB 0806 - OK 4 9.613 OK 0.358 P 6 9/16 5/8 5 5/16 21/32 9 7/8 6 1/16 OK OK OK 6 17/32 3 1/4 6 1/16 8 3/16 3/16 OK OK NIL -
SLB 0813 - OK 4 9.308 OK 0.363 P 6 9/16 5/8 5 5/16 21/32 10 15/16 6 1/16 OK OK F 6 9/16 3 1/4 6 1/16 7 7/16 2/4 OK OK NIL -
SLB 0821 - OK 4 9.633 OK 0.378 P 6 9/16 5/8 5 5/16 21/32 10 5/8 6 1/16 OK OK F 6 9/16 3 1/4 6 1/16 8 3/8 3/16 OK OK NIL -
SLB 0788 - OK 4 9.659 OK 0.375 P 6 9/16 5/8 5 5/16 21/32 11 1/8 6 1/16 OK OK F 6 17/32 3 1/4 6 1/16 7 13/32 3/16 OK OK NIL -
SLB 0796 - OK 4 9.660 OK 0.370 P 6 9/16 5/8 5 5/16 21/32 7 5/16 6 1/16 OK OK OK 6 9/16 3 1/4 6 1/16 8 1/4 5/8 OK OK NIL -
SLB 1065 - OK 4 9.648 OK 0.365 P 6 17/32 9/16 5 5/16 21/32 10 7/16 6 1/16 OK OK F 6 17/32 3 1/4 6 1/16 7 13/16 3/16 OK OK NIL -
SLB 0836 - OK 4 9.616 OK 0.36 P 6 9/16 5/8 5 5/16 21/32 7 5/16 6 1/16 OK OK OK 6 4/7 3 1/4 6 1/16 7 7/8 01-Mar OK OK NIL -
Final Class : P - Premium Class #2 - Class 2 ID Coating Condition : 1 - 100% , 2 - 80% -99% , 3 - 65% - 79% & 4 - Below 65%
DS-Damaged Seal , DT-Damaged Thread , CT-Corroded Thread , WT-Worned Thread, CS-Corroded Seal , GT-Galled Thread , ST-Stretched Thread , EW-Eccentric Wear , WO-Washout , CR-Cracked , HBD-Hard Face Damage & F-H.B FLAT
COMMENTS: ABOVE MENTIONED DRILL PIPE INSPECTED AND FOUND OK AT THTE TIME OF THE INSPECTION.
SURYA MANI
CUSTOMER SIGNATURE Inspector
ASNI Level II Cert No. : TS/1293/MTLYC-II
ASNI Level II Cert Validity :14-03-2027
This field report is issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, repairer or operator of any warranty, express or implied and Tubestar's liability shall be limited to the acts and omissions of its employees and subcontractors. Under no Circumstances shall Tubestar be liable for any injury or damage to any person or
property occurring by any reason of negligent operation, misuse, of or any defect in material, machinery, equipment or other items other than by defects in items actually inspected by Tubestar and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed byTubestar and which are covered by this report. this field report and the recommendation contained within it are
based upon the conditions and practices observed and information available to Tubestar personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings on the criteria shown in this report are intended as guideline only. Tubestar does not accept responsibility for the control or correction of conditions
F OPN 001 TUB DS1, Rev.05/09.10.2016
DRILL PIPE INSPECTION TALLY SHEET
CUSTOMER : SHREE INTERNATIONAL (HVC) LOCATION : KALAMBOLI RIG : NA REPORT NO : TS/HVC/5.00DP/MUM/11-2024/001
SHEET NO : 04 OF 05 DATE :01-11-2024
PIPE OD PIPE GRADE WEIGHT LBS/FT NOM. WALL THICKNESS THREAD CONNECTION RANGE
5" S-135 19.50 0.362 NC 50 II
CATEGORY
1 2 3 4 5 HDLS
SPECIFICATION : API RP 7G-2 DS1 STD. X NS - 2 CUST. / SPECIAL
All Dimensions Are In Inches
ID BOX TOOL JOINT PIN TOOL JOINT
ID EMI OD Coating LENGTH OD Remain Final Shoulder Counter Bore Tong Bevel BOX MPI/UT HB Pin PIN Bevel Tong Pin Neck Pin MPI/UT HB
No. Condition Condition MTR Gauge Wall Thick. Class OD Width Dia Depth Space Dia COND. COND. COND. OD ID Diameter Space Length COND. UPSET COND. YOM
SLB 0793 - OK 4 9.630 OK 0.361 P 6 19/32 5/8 5 5/16 21/32 7 7/16 6 1/16 OK OK OK 6 9/16 3 1/4 6 1/16 8 3/8 9/32 OK OK NIL -
SLB 1057 - OK 3 9.610 OK 0.382 P 6 17/32 19/32 5 5/16 21/32 11 1/16 6 1/16 OK OK F 6 9/16 3 1/4 6 1/16 7 3/4 5/32 OK OK NIL -
SLB 0805 - OK 4 9.645 OK 0.390 P 6 17/32 19/32 5 5/16 21/32 11 6 1/16 OK OK F 6 9/16 3 1/4 6 1/16 7 11/16 3/16 OK OK NIL -
SLB 0846 - OK 4 9.425 OK 0.375 P 6 17/32 19/32 5 5/16 21/32 9 5/8 6 1/16 OK OK F 6 17/32 3 1/4 6 1/16 7 1/2 1/4 OK OK NIL -
SLB 1058 - OK 4 9.602 OK 0.386 P 6 17/32 19/32 5 5/16 21/32 11 1/16 6 1/16 OK OK F 6 17/32 3 1/4 6 1/16 7 3/4 3/16 OK OK NIL -
SLB 0815 - OK 4 9.615 OK 0.380 P 6 9/16 5/8 5 5/16 21/32 10 1/8 6 1/16 OK OK F 6 15/32 3 1/4 6 1/16 8 5/16 5/32 OK OK NIL -
SLB 0797 - OK 4 9.647 OK 0.386 P 6 17/32 19/32 5 5/16 21/32 11 1/16 6 1/16 OK OK F 6 9/16 3 1/4 6 1/16 8 1/8 3/16 OK OK NIL -
SLB 0816 - OK 4 9.320 OK 0.390 P 6 17/32 19/32 5 5/16 21/32 10 7/16 6 1/16 OK OK F 6 19/32 3 1/4 6 1/16 8 1/4 1/4 OK OK NIL -
SLB 0804 - OK 4 9.618 OK 0.389 P 6 17/32 19/32 5 5/16 21/32 7 3/8 6 1/16 OK OK OK 6 1/2 3 1/4 6 1/16 6 3/8 3/16 OK OK NIL -
SLB 0811 - OK 4 9.617 OK 0.381 P 6 17/32 19/32 5 5/16 21/32 10 5/8 6 1/16 OK OK F 6 17/32 3 1/4 6 1/16 7 3/4 3/16 OK OK NIL -
SLB 0798 - OK 4 9.683 OK 0.361 P 6 9/16 5/8 5 5/16 21/32 7 7/16 6 1/16 OK OK OK 6 9/16 3 1/4 6 1/16 7 1/4 5/32 OK OK NIL -
SLB 0805 - OK 4 9.614 OK 0.385 P 6 19/32 5/8 5 5/16 21/32 6 15/16 6 1/16 OK OK OK 6 17/32 3 1/4 6 1/16 7 3/8 3/16 OK OK NIL -
SLB 0829 - OK 4 9.661 OK 0.382 P 6 19/32 5/8 5 5/16 21/32 11 1/16 6 1/16 OK OK F 6 9/16 3 1/4 6 1/16 7 5/8 5/32 OK OK NIL -
SLB 0790 - OK 4 9.637 OK 0.384 P 6 19/32 5/8 5 5/16 21/32 7 7/8 6 1/16 OK OK OK 6 9/16 3 1/4 6 1/16 6 1/16 3/16 OK OK NIL -
SLB 9834 - OK 4 9.63 OK 0.389 P 6 9/16 5/8 5 5/16 21/32 11 1/16 6 1/16 OK OK F 6 9/16 3 1/4 6 1/16 7 13/16 1/4 OK OK NIL -
Final Class : P - Premium Class #2 - Class 2 ID Coating Condition : 1 - 100% , 2 - 80% -99% , 3 - 65% - 79% & 4 - Below 65%
DS-Damaged Seal , DT-Damaged Thread , CT-Corroded Thread , WT-Worned Thread, CS-Corroded Seal , GT-Galled Thread , ST-Stretched Thread , EW-Eccentric Wear , WO-Washout , CR-Cracked , HBD-Hard Face Damage & F-H.B FLAT
COMMENTS: ABOVE MENTIONED DRILL PIPE INSPECTED AND FOUND OK AT THTE TIME OF THE INSPECTION.
SURYA MANI
CUSTOMER SIGNATURE Inspector
ASNI Level II Cert No. : TS/1293/MTLYC-II
ASNI Level II Cert Validity :14-03-2027
This field report is issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, repairer or operator of any warranty, express or implied and Tubestar's liability shall be limited to the acts and omissions of its employees and subcontractors. Under no Circumstances shall Tubestar be liable for any injury or damage to any person or
property occurring by any reason of negligent operation, misuse, of or any defect in material, machinery, equipment or other items other than by defects in items actually inspected by Tubestar and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed byTubestar and which are covered by this report. this field report and the recommendation contained within it are
based upon the conditions and practices observed and information available to Tubestar personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings on the criteria shown in this report are intended as guideline only. Tubestar does not accept responsibility for the control or correction of conditions
F OPN 001 TUB DS1, Rev.05/09.10.2016
DRILL PIPE INSPECTION TALLY SHEET
CUSTOMER : SHREE INTERNATIONAL (HVC) LOCATION : KALAMBOLI RIG : NA REPORT NO : TS/HVC/5.00DP/MUM/11-2024/001
SHEET NO : 05 OF 05 DATE :01-11-2024
PIPE OD PIPE GRADE WEIGHT LBS/FT NOM. WALL THICKNESS THREAD CONNECTION RANGE
5" S-135 19.50 0.362 NC 50 II
CATEGORY
1 2 3 4 5 HDLS
SPECIFICATION : API RP 7G-2 DS1 STD. X NS - 2 CUST. / SPECIAL
All Dimensions Are In Inches
ID BOX TOOL JOINT PIN TOOL JOINT
ID EMI OD Coating LENGTH OD Remain Final Shoulder Counter Bore Tong Bevel BOX MPI/UT HB Pin PIN Bevel Tong Pin Neck Pin MPI/UT HB
No. Condition Condition MTR Gauge Wall Thick. Class OD Width Dia Depth Space Dia COND. COND. COND. OD ID Diameter Space Length COND. UPSET COND. YOM
HVC14 - OK 2 9.527 OK 0.375 P 6 1/2 5/8 5 5/16 21/32 12 6 1/16 OK OK F 6 3/8 3 7/32 6 1/16 9 1/16 15/32 OK OK NA -
HVC02 - OK 4 9.582 OK 0.355 P 6 5/16 15/32 5 5/16 21/32 9 6 1/16 OK OK F 6 5/16 2 13/16 6 1/16 6 3/16 13/32 OK OK NA -
HVC03 - OK 4 9.476 OK 0.353 P 6 5/16 7/16 5 5/16 21/32 10 7/16 6 1/16 OK OK F 6 5/16 2 3/4 6 1/16 7 1/4 1/2 OK OK NA -
HVC04 - OK 4 9.699 OK 0.355 P 6 5/16 1/2 5 5/16 21/32 12 1/2 6 1/16 OK OK F 6 5/16 2 3/4 6 1/16 9 3/8 15/32 OK OK NA -
HVC05 - OK 4 9.474 OK 0.384 P 6 5/8 5/8 5 5/16 21/32 7 11/16 6 1/16 OK OK OK 6 9/16 3 3/32 6 1/16 8 9/16 9/32 OK OK NA -
HVC06 - OK 3 9.575 OK 0.360 P 6 1/2 5/8 5 5/16 21/32 12 1/4 6 1/16 OK OK F 6 17/32 3 5/32 6 1/16 8 1/2 9/32 OK OK NA -
AS41215 - OK 3 9.621 OK 0.363 P 6 9/16 5/8 5 5/16 21/32 12 6 1/16 OK OK F 6 17/32 3 3/16 6 1/16 8 15/16 15/32 OK OK NA -
HVC08 - OK 4 9.585 OK 0.362 P 6 1/2 11/16 5 5/16 21/32 12 6 1/16 OK OK F 6 17/32 3 1/4 6 1/16 8 5/8 9/32 OK OK NA -
HVC09 - OK 3 9.600 OK 0.375 P 6 5/8 5/8 5 5/16 21/32 11 7/8 6 1/16 OK OK F 6 19/32 3 3/16 6 1/16 8 7/8 15/32 OK OK NA -
HVC10 - OK 4 9.658 OK 0.363 P 6 9/16 5/8 5 5/16 21/32 13 1/2 6 1/16 OK OK F 6 15/32 3 5/16 6 1/16 10 5/8 9/32 OK OK NA -
HVC11 - OK 2 9.565 OK 0.386 P 6 5/8 11/16 5 5/16 21/32 8 1/4 6 1/16 OK OK OK 6 19/32 3 3/16 6 1/16 8 15/16 15/32 OK OK NA -
HVC12 - OK 3 9.587 OK 0.362 P 6 5/8 5/8 5 5/16 21/32 11 5/16 6 1/16 OK OK F 6 1/2 3 1/4 6 1/16 8 1/2 9/32 OK OK NA -
Final Class : P - Premium Class #2 - Class 2 ID Coating Condition : 1 - 100% , 2 - 80% -99% , 3 - 65% - 79% & 4 - Below 65%
DS-Damaged Seal , DT-Damaged Thread , CT-Corroded Thread , WT-Worned Thread, CS-Corroded Seal , GT-Galled Thread , ST-Stretched Thread , EW-Eccentric Wear , WO-Washout , CR-Cracked , HBD-Hard Face Damage & F-H.B FLAT
COMMENTS: ABOVE MENTIONED DRILL PIPE INSPECTED AND FOUND OK AT THTE TIME OF THE INSPECTION.
SURYA MANI
CUSTOMER SIGNATURE Inspector
ASNI Level II Cert No. : TS/1293/MTLYC-II
ASNI Level II Cert Validity :14-03-2027
This field report is issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, repairer or operator of any warranty, express or implied and Tubestar's liability shall be limited to the acts and omissions of its employees and subcontractors. Under no Circumstances shall Tubestar be liable for any injury or damage to any person or
property occurring by any reason of negligent operation, misuse, of or any defect in material, machinery, equipment or other items other than by defects in items actually inspected by Tubestar and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed byTubestar and which are covered by this report. this field report and the recommendation contained within it are
based upon the conditions and practices observed and information available to Tubestar personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings on the criteria shown in this report are intended as guideline only. Tubestar does not accept responsibility for the control or correction of conditions
F OPN 001 TUB DS1, Rev.05/09.10.2016