0% found this document useful (0 votes)
37 views2 pages

LP12-5 4

The LP12-5.4 is a 12V lead-acid battery with a nominal capacity of 5.4AH, designed for various applications including UPS and emergency power supply. It features dimensions of 90mm x 70mm x 101mm and operates effectively within a temperature range of -15°C to 40°C. The battery is made of ABS material, weighs approximately 1.65 kg, and requires recycling due to its lead content.

Uploaded by

Hernan Castillo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views2 pages

LP12-5 4

The LP12-5.4 is a 12V lead-acid battery with a nominal capacity of 5.4AH, designed for various applications including UPS and emergency power supply. It features dimensions of 90mm x 70mm x 101mm and operates effectively within a temperature range of -15°C to 40°C. The battery is made of ABS material, weighs approximately 1.65 kg, and requires recycling due to its lead content.

Uploaded by

Hernan Castillo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

LP SERIES-General Purpose

LP12-5.4 (12V5.4AH)
Specification
Nominal Voltage 12V
Nominal Capacity(20HR) 5.4AH
Length 90 1mm (3.54 inches)
Width 70 1mm (2.76 inches) Mainten LP12-5
Dimensions ance-fr
CO NS
ee Seale .4(12V5
d Lead-ac
.4AH)
Container Height 101 2mm (3.98 inches) Sta nd by
TA NT

us e:
VO LTAG
E CH AR
13 .5- 13
id Batte
ry
GE
Cy cle .8
us e: V
14 .4- 15
Total Height (with Terminal) 107 2mm (4.21 inches) War nin
Ini tia l cu
Ris k of g:
fire
rre nt: .0
L es s t ha
n
V
1.6 2 A
hea t abo , exp losi
ve the on, or
50C
O bur
, or inci ns. Do not

Approx 1.65 kg (3.64lbs)


ner ate dis ass

Approx Weight MH 268


. emb le,

66

Terminal T1
LEOCH
BAT
MADE TERY CO.,LTD
IN CHINA . Pb.
Non -spi llab
BAT TERY
MUS T BE le
REC YCL
ED
Pb
Container Material ABS
5.40 AH/0.27A (20hr ,1.80V/cell,250C/770F)
5.02 AH/0.502A (10hr,1.80V/cell,250C/770F) Applications
Rated Capacity 4.54 AH/0.907A (5hr,1.75V/cell,250C/770F)
3.96 AH/1.32A (3hr,1.75V/cell,250C/770F) All purpose
3.28 AH/3.28A (1hr,1.60V/cell,250C/770F) Uninterruptable Power Supply (UPS)
Max. Discharge Current 81A (5s) Electric Power System (EPS)
Internal Resistance Approx 30mÙ Emergency backup power supply
0
Discharge : -15 50 C (5 122 F) 0
Emergency light
Operating Temp.Range Charge : 0 400C (32 1040F) Railway signal
Storage : -15 400C (5 1040F)
Aircraft signal
Nominal Operating Temp. Range 25 30C (77 50F ) Alarm and security system
Initial Charging Current less than 1.62A.Voltage Electronic apparatus and equipment
Cycle Use
14.4V~15.0V at 250 C(770 F)Temp. Coefficient -30mV/0C
Communication power supply
No limit on Initial Charging Current Voltage DC power supply
Standby Use
13.5V~13.8V at 250 C(770 F)Temp. Coefficient -20mV/0C Auto control system
40o C (104o F) 103%
Capacity affected by
25o C ( 77o F) 100%
Temperature VdS
0o C ( 32o F) 86%
Allsai LP series batteries may be stored for up to 6 months
Self Discharge at 25 C(70 70F) and then a freshening charge is t est ed

required. For higher temperatures the time interval will be 9 Germany

shorter.

0
Constant Current Discharge (Amperes) at 25 C (77 0F )
F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h
1.85V/cell 10.4 7.23 5.96 5.17 4.15 3.19 2.61 1.59 1.21 0.998 0.847 0.734 0.583 0.485 0.267
1.80V/cell 12.7 8.62 6.91 5.85 4.59 3.48 2.81 1.69 1.28 1.05 0.883 0.766 0.605 0.502 0.270
1.75V/cell 15.1 9.75 7.62 6.37 4.90 3.69 2.95 1.77 1.32 1.08 0.907 0.785 0.621 0.512 0.273
1.70V/cell 17.1 10.8 8.25 6.84 5.15 3.84 3.08 1.84 1.36 1.11 0.930 0.804 0.630 0.521 0.278
1.65V/cell 18.9 11.6 8.73 7.18 5.37 3.99 3.21 1.89 1.40 1.13 0.950 0.819 0.641 0.528 0.281
1.60V/cell 19.8 12.1 9.09 7.40 5.52 4.08 3.28 1.95 1.43 1.16 0.970 0.835 0.654 0.537 0.283

0
Constant Power Discharge (Watts/cell) at 25 C (77 0F )
F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h
1.85V/cell 19.6 13.8 11.5 10.0 8.09 6.25 5.14 3.15 2.41 1.99 1.69 1.47 1.17 0.978 0.540
1.80V/cell 23.8 16.3 13.2 11.2 8.89 6.77 5.50 3.33 2.52 2.08 1.76 1.53 1.21 1.01 0.543
1.75V/cell 27.8 18.2 14.4 12.1 9.43 7.16 5.76 3.46 2.59 2.13 1.79 1.55 1.23 1.02 0.544
1.70V/cell 31.2 19.9 15.4 12.9 9.84 7.39 5.97 3.58 2.67 2.17 1.83 1.58 1.25 1.03 0.551
1.65V/cell 33.9 21.1 16.1 13.5 10.2 7.63 6.17 3.66 2.72 2.21 1.86 1.61 1.26 1.04 0.556
1.60V/cell 35.1 21.7 16.6 13.7 10.3 7.72 6.26 3.75 2.77 2.25 1.89 1.63 1.28 1.05 0.556

1
Dimensions

T1 Terminal
Unit: mm [inches]

70 1
101 1
107 1
4.75(0.187)

3.2(0.126)
73
6.35(0.25) 90 1
0.8(0.031)

Discharge Characteristics Float Charging Characteristics


12V
Battery
V
0
Temperature:25 C( 0
77F) Charge Charging Charging
Volume Current Voltage
13.0 0
(V) 0.10CA-2.25V/cell temperature25 C
% (XCA)

12.0
0.25
120 15.0
110 Charged Volume
11.0
0.20
Terminal Voltage(V)

100
0.093C 0.05C 14.0
0.207C 90 Charge Voltage
10.0 0.4C 80 0.15 (Constant 2.25v/cell)
70 13.0
1C 0.628C
9.0 60
After 50% Discharge
50 0.10
12.0
40 After 100% Discharge
8.0 30
3C 2C 0.05 11.0
20
6 10 Charging Current
1 2 4 8 10 20 40 60 2 4 6 8 10 20
0 0
Min H
0 4 8 12 16 20 24 28 32 36 40
Discharge Time Charging Time(hours)

Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life

10
120 8
6
100 A
0 .0 5 C 5
Charging voltage :
0 .1 C A 4
2.25V/cell
80 3
0. 2 C A
Life expectancy(year)
Capacity %

60 2
1 .0 C A
40
2 .0 C A 3.0 CA 1
20

0 0.5
-20 -10 0 10 20 30 40 50 20 30 40 50 0
C
68 86 104 122 O
F
0
Temperature( C) Battery temperature

Cycle Life in Relation to Depth of Discharge Self Discharge Characteristics


Testing condition
100
Discharging:current 0.17C (FV 1.7V/cell);
Charging:current 0.25C max, voltage 2.45V/cell; 100C A
Charging volume:125% of discharged capacity. 80
250C
Remaining Capacity(%)

120 60
B
0
400C 30 C
100 40

80 C
20
Capcity(%)

60
100% 50% 30% 0
DOD DOD DOD 2 4 6 8 10 12
40
Ambient Termperature: Storage Time(Months)
25oC (77oF)
20 No supplementary charge required
A (Carry out supplementary charge before use if 100% capacity is required.)
0 Supplementary charge required before use.Optional charging way as below:
0 200 400 600 800 1000 1200 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell.
B 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell.
Number of Cycles 3.Charged for 8~10hours at limted current 0.05CA .

Supplementary charge may often fail to recover the capacity.


C The battery should never be left standing till this is reached.