0% found this document useful (0 votes)
31 views91 pages

Footing - Design Calculation

The document provides detailed footing design calculations for a two-storey residential building, including definitions of key terms, code references, and design parameters. It outlines the analysis of soil pressure, buoyancy, sliding, and overturning checks, ensuring the footing's structural integrity under various load conditions. The design adheres to ACI 318M - 14 standards and includes specific dimensions and material properties for the footing and columns.

Uploaded by

Dennis Simara
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
31 views91 pages

Footing - Design Calculation

The document provides detailed footing design calculations for a two-storey residential building, including definitions of key terms, code references, and design parameters. It outlines the analysis of soil pressure, buoyancy, sliding, and overturning checks, ensuring the footing's structural integrity under various load conditions. The design adheres to ACI 318M - 14 standards and includes specific dimensions and material properties for the footing and columns.

Uploaded by

Dennis Simara
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 91

Footing Design: Design Calculation Page 1 of 91

FOOTING DESIGN CALCULATIONS


Project Name : Two-Storey Residential Bldg.
Client Name : Engr. Christialn Karl Villaluz
Engineer Name : Angela L. Morada
Design File : C:\Users\Danilo Simara III\Dropbox (Old)
\PC\Documents\CM\Ilai\RCDC\Footing\Footing.rcdx
Analysis File : C:\Users\Danilo Simara III\Dropbox (Old)
\PC\Documents\CM\Ilai\STAAD\ILAYY.STD
Analysis Last Modified : 12/31/2024 12:03:15 AM

Definitions:
1. A = Plan area of footing base in 'sqmm'
2. Ast (min) = Area of longitudinal reinforcement as per code in 'sqmm'
3. Ast Prv = Area of tensile reinforcement provided in 'sqmm'
4. Ast Rqd = Area of longitudinal reinforcement from bearing moment
and minimum % steel provided by user and as per code
in 'sqmm'
5. Av = Area of shear reinforcement required in 'sqmm/m'
6. AvPrv = Area of shear reinforcement provided in 'sqmm/m'
7. A1 = Bearing area of footing at slope of 1:2 in 'sqmm'
8. A2 = C/s Area of column in 'sqmm'
9. B = Width of footing base in 'mm'
10. Beff = Effective width of footing in 'mm'
11. Boff = Footing offset along B in 'mm'
12. BoffB = Footing offset along B above column in plan in 'mm'
13. BoffT = Footing offset along B below column in planin 'mm'
14. B1 = Width of sloped footing at top in 'mm'
15. ColOff = Column offset in sloped footing in 'mm'
16. Cx = Width of column in 'mm'
17. Cy = Length of Column in 'mm'
18. D = Depth of footing in 'mm'
19. d = Effective Depth of footing in 'mm'
20. Dfd = Depth of founding layer in 'm'
21. Dw = Ground water level in 'm'
22. Ec = Modulus of elasticity of concrete in 'N/sqmm'
23. Es = Modulus of elasticity of steel in 'N/sqmm'
24. Foss = Safety factor against sliding
25. Fosu = Safety factor against uplift
26. Fst = Stress in steel in 'N/sqmm'
27. F'c = Characteristic strength of concrete in 'N/sqmm'
28. Icr = Moment of Inertia of concrete crack section in 'mm4'
29. L = Length of footing base in 'mm'
30. Leff = Effective length of footing in 'mm'

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 2 of 91

31. Loff = Footing offset along L in 'mm'


32. LoffL = Footing offset along L on left side of column in 'mm'
33. LoffR = Footing offset along L on right side of column in 'mm'
34. L1 = Length of sloped footing at top in 'mm'
35. Mcr = Cracking Moment
36. Mx = Bending Moment along column D in 'kNm'
37. Mex = Eccentricity moment along column D
38. Mxx = Total Bending Moment along column D (Mx + Mex)
39. My = Bending Moment along column B in 'kNm'
40. Mey = Eccentricity moment along column B
41. Myy = Total Bending Moment along column B (My + Mey)
42. Muy = Factored moment along column B in 'kNm'
43. Mux = Factored moment along column D in 'kNm'
44. Netdown = Net downward load in 'kN'
45. OB = Maximum permissible offset On bottom side Of column
46. OL = Maximum permissible offset On left side Of column
47. Or = Maximum permissible offset On right side Of column
48. OT = Maximum permissible offset On top side Of column
49. P = Axial load For footing sizing In 'kN'
50. Pcr(axial) = Design pressure at the critical section in 'kN/sqm'
51. P1 = Soil pressure at corner 1 In 'kN/sqm'
52. P2 = Soil pressure at corner 2 'kN/sqm'
53. P3 = Soil pressure at corner 3 'kN/sqm'
54. P4 = Soil pressure at corner 4 'kN/sqm'
55. q = Surcharge Load In 'kN/sqm'
56. sp = Spacing Between bars at outer most layer In 'mm'
57. SPu = Upward Soil Pressure In 'kN/sqm'
58. SPuL = Upward Soil Pressure from left
59. SPuR = Upward Soil Pressure from right
60. SPuB = Upward Soil Pressure from bottom
61. SPuT = Upward Soil Pressure from top
62. Temp1 = Peak Hydration temperature In Degree
63. Temp2 = Seasonal Temperature Variations In Degree
64. Vs Capacity = Shear strength capacity Of provided shear reinforcement
'kN'
65. Vs = Nominal shear strength provided by shear reinforcement,
in 'kN'
66. Vc = Nominal shear strength provided by concrete in 'kN'
67. Vu = Design shear force in 'kN'
68. Vus = Strength of shear reinforcement in 'kN'
69. Vx = Shear along major axis in 'kN'
70. Vy = Shear along minor axis in 'kN'
71. Waterpr = Upward water pressure in 'kN/sqm'

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 3 of 91

72. Waterup = Upward force due to water in 'kN/sqm'


73. WFoot = Add. Wt. due to difference in concrete and soil density in
'kN'
74. WFootc = Weight of footing and column with concrete density in
'kN'
75. WSoil = Weight of soil covering footing area in 'kN'
76. y = Neutral axis depth.
77. Zx = Section modulus of footing base along L in 'mm4'
78. Zy = Section modulus of footing base along B in 'mm4'
79. Φ = Strength reduction factor in shear
80. Φ1 = Strength reduction factor in concrete bearing
81. Φ1Pnb = Bearing strength of column in 'kN'

Code References:
ACI 318M - 14
Sr.No. Item Clause / Table
1. Ptmax : 7.3.3.1, 8.3.3.1, 9.3.3.1
2. Ptmin : 7.6.1.1 & 8.6.1.1/7.7.2.3
3. Vc : 22.6.5
4. Av : 22.5.10.5 & 22.6.7
5. Max Stirrup Spacing : 9.7.6.2 & 10.7.6.5
6. Vs : 22.5.1.2
7. fs,perm : 24.3.2.1
8. fc,perm : 22.2.2.4.1
9. Wcr : Eq 4.2(a)

Design Code : ACI 318M - 14


Footing No : FC1
Column No : C1 ( 400 mm X 400 mm)
Analysis No : 1

Concrete Grade : C28


Steel Grade : Fy415
Clear Cover : 40 mm
Dfd : 1.5 m
Dw : 10 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 0 %
Permissible SBC Increase for Wind = 0 %

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 4 of 91

Live Load Reduction = 0 %


Permissible area of loss of contact = 0 %

Design cross section by Consider : Average pressure


overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 4100mm X 4100mm X 300mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 126.07 kN
Soil Weight, S1 = 0 kN
Total Weight, W1 = F1 + S1
= 126.08 kN
Offset Along L (Loff) = 1850 mm
Offset Along B (Boff) = 1850 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 313
Critical Load Combination = [55] : (LOAD 3: DL1) +(LOAD 4: DL2) +
(LOAD 5: LL1) +(LOAD 6: LL2) -0.71 (LOAD
2: EZ) +(LOAD 7: RLL)
Pcomb = 148.61 kN
P = Pcomb + W1
P = 274.68 kN
Mx = -15.42 kNm
My = -26.64 kNm
P/A = 16.34 kN/sqm
Mx/Zx = -1.34 kN/sqm
My/Zy = -2.32 kN/sqm
Maximum Soil Pressure = 20 kN/sqm
Allowable Soil Pressure = 1x200 kN/sqm
= 200 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 123
Critical Load Combination = [23] : 0.68 (LOAD 3: DL1)
+0.68 (LOAD 4: DL2) +0.3
(LOAD 1: EX) +(LOAD 2:
EZ)
Pcomb = 30.44 kN
P = Pcomb + W1 x 0.68
P = 116.17 kN
Mx = 16.54 kNm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 5 of 91

My = 40.72 kNm
P/A = 6.91 kN/sqm
Mx/Zx = 1.44 kN/sqm
My/Zy = 3.55 kN/sqm
Minimum Soil Pressure = 1.93 kN/sqm
> 0

Check For Buoyancy:


Depth of Water Table is below Depth of Foundation, hence Buoyancy check Not Applicable

Check For Sliding:


Critical Analysis Load Combination = 123
[23] : 0.68 (LOAD 3: DL1) +0.68 (LOAD 4:
Critical Load Combination =
DL2) +0.3 (LOAD 1: EX) +(LOAD 2: EZ)
Pcomb = 30.44 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 34.59 kN
shear Vy = 17.21 kN
Resultant sliding force = 38.63 kN
Downward force = Pcomb + (F1 + S1) x 0.68
= 116.17 kN
Upward water pressure = 0 kN
Net downward force = 116.17 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 46.47 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.2
> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 124
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -0.3
Critical Load Combination =
(LOAD 1: EX) +(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 55.47 kN
Moment Mx = 24.57 kNm
P = Pcomb + (F1 + S1) x 0.68
= 141.2 kN
Stabilizing Moment for P = 289.46 kNm
DeStabilizing Moment = 24.57 kNm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 6 of 91

Overturning Factor of safety = 11.78


Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 123
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2)
Critical Load Combination =
+0.3 (LOAD 1: EX) +(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 30.44 kN
Moment My = 40.72 kNm
P = Pcomb + (F1 + S1) x 0.68
= 116.17 kN
Stabilizing Moment for P = 238.14 kNm
DeStabilizing Moment = 40.72 kNm
Overturning Factor of safety = 5.85
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 2: EZ) +0.5 (LOAD 7: RLL)
Pu = 184.13 kN
Mux = -21.61 kNm
Muy = -37.45 kNm
P/A = 10.95 kN/sqm
Mx/Zx = -1.88 kN/sqm
My/Zy = -3.26 kN/sqm

Deff = 252 mm
Beff = 4100 mm
SPu = 12.83 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 90.05 kNm
Ast Rqd = 2460 sqmm
Ast (min) = 2460 sqmm
Ast Prv (Distributed Across Total Width) = 15 - #16 @ 300
= 3015.9 sqmm

Top Steel Along L:


Ast Prv (Distributed Across Total Width) = 15 - #16 @ 300 c/c
= 3015.9 sqmm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 7 of 91

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 2: EZ) +0.5 (LOAD 7: RLL)
Pu = 184.13 kN
Mux = -21.61 kNm
Muy = -37.45 kNm
P/A = 10.95 kN/sqm
Mx/Zx = -1.88 kN/sqm
My/Zy = -3.26 kN/sqm

Deff = 236 mm
Leff = 4100 mm
SPu = 14.21 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 99.73 kNm
Ast Rqd = 2460 sqmm
Ast (min) = 2460 sqmm
Ast Prv (Distributed Across Total
= 15 - #16 @ 300
Length)
= 3015.9 sqmm

Top Steel Along B:


Ast Prv (Distributed Across Total
= 15 - #16 @ 300 c/c
Length)
= 3015.9 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 252 mm
Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 2: EZ) +0.5 (LOAD 7: RLL)
Pu = 184.13 kN
Mux = -21.61 kNm
Muy = -37.45 kNm
P/A = 10.95 kN/sqm
Mx/Zx = -1.88 kN/sqm
My/Zy = -3.26 kN/sqm

Deff = 252 mm
Beff = 4100 mm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 8 of 91

SPu = 12.83 kN/sqm


Vu = SPu X (Loff - d) X B
= 84.09 kN
φVc = 687.43 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 236 mm
Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) -(LOAD 2: EZ) +0.5
(LOAD 7: RLL)
Pu = 184.13 kN
Mux = -21.61 kNm
Muy = -37.45 kNm
P/A = 10.95 kN/sqm
Mx/Zx = -1.88 kN/sqm
My/Zy = -3.26 kN/sqm

Deff = 236 mm
Leff = 4100 mm
SPu = 14.21 kN/sqm
Vu = SPu X (Boff - d) X L
= 94.06 kN
φVc = 645.77 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 122 mm

Critical Analysis Load Combination = 405


Critical Load Combination = [126] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 186.67 kN
Mux = 12.71 kNm
Muy = -13.59 kNm
P/A = 11.1 kN/sqm
Mx/Zx = 1.11 kN/sqm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 9 of 91

My/Zy = -1.18 kN/sqm

Deff = 244 mm
Leff = 644 mm
Beff = 644 mm
Punching Perimeter = 2576 mm
Punching Area = 628544 sqmm
SPu = Average Pressure
= 11.1 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 182.07 kN
φVn = 1247.23 kN
φVc = 823.17 kN
No Shear
Vu < φVc Reinforcement
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 405
Critical Load Combination = [126] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) -(LOAD 1: EX) +0.5
(LOAD 7: RLL)
Pu = 186.67 kN
A2 = 0.16 sqm
A1 = 2.56 sqm
Base Area = 16.81 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 4
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 4950.4 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 14


Footing No : FC2
Column No : C2 ( 400 mm X 400 mm)

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 10 of 91

Analysis No : 33

Concrete Grade : C28


Steel Grade : Fy415
Clear Cover : 40 mm
Dfd : 1.5 m
Dw : 10 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 0 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 0 %

Design cross section by Consider : Average pressure


overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 2750mm X 2750mm X 300mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 56.72 kN
Soil Weight, S1 = 0 kN
Total Weight, W1 = F1 + S1
= 56.72 kN
Offset Along L (Loff) = 1175 mm
Offset Along B (Boff) = 1175 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 313
Critical Load Combination = [55] : (LOAD 3: DL1) +(LOAD 4: DL2) +
(LOAD 5: LL1) +(LOAD 6: LL2) -0.71 (LOAD
2: EZ) +(LOAD 7: RLL)
Pcomb = 197.02 kN
P = Pcomb + W1
P = 253.74 kN
Mx = -13.53 kNm
My = -14.9 kNm
P/A = 33.55 kN/sqm
Mx/Zx = -3.9 kN/sqm
My/Zy = -4.3 kN/sqm
Maximum Soil Pressure = 41.75 kN/sqm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 11 of 91

Allowable Soil Pressure = 1x200 kN/sqm


= 200 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 124
Critical Load Combination = [24] : 0.68 (LOAD 3: DL1)
+0.68 (LOAD 4: DL2) -0.3
(LOAD 1: EX) +(LOAD 2:
EZ)
Pcomb = 59.61 kN
P = Pcomb + W1 x 0.68
P = 98.18 kN
Mx = 24.36 kNm
My = 20.62 kNm
P/A = 12.98 kN/sqm
Mx/Zx = 7.03 kN/sqm
My/Zy = 5.95 kN/sqm
Minimum Soil Pressure = 0 kN/sqm
> 0

Check For Buoyancy:


Depth of Water Table is below Depth of Foundation, hence Buoyancy check Not Applicable

Check For Sliding:


Critical Analysis Load Combination = 124
[24] : 0.68 (LOAD 3: DL1) +0.68 (LOAD 4:
Critical Load Combination =
DL2) -0.3 (LOAD 1: EX) +(LOAD 2: EZ)
Pcomb = 59.61 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 15.15 kN
shear Vy = 23.47 kN
Resultant sliding force = 27.93 kN
Downward force = Pcomb + (F1 + S1) x 0.68
= 98.18 kN
Upward water pressure = 0 kN
Net downward force = 98.18 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 39.27 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.41
> 1.2

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 12 of 91

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 124
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -0.3
Critical Load Combination =
(LOAD 1: EX) +(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 59.61 kN
Moment Mx = 24.36 kNm
P = Pcomb + (F1 + S1) x 0.68
= 98.18 kN
Stabilizing Moment for P = 135 kNm
DeStabilizing Moment = 24.36 kNm
Overturning Factor of safety = 5.54
Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 124
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -0.3
Critical Load Combination =
(LOAD 1: EX) +(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 59.61 kN
Moment My = 20.62 kNm
P = Pcomb + (F1 + S1) x 0.68
= 98.18 kN
Stabilizing Moment for P = 135 kNm
DeStabilizing Moment = 20.62 kNm
Overturning Factor of safety = 6.55
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 2: EZ) +0.5 (LOAD 7: RLL)
Pu = 243.31 kN
Mux = -19.11 kNm
Muy = -20.74 kNm
P/A = 32.17 kN/sqm
Mx/Zx = -5.51 kN/sqm
My/Zy = -5.98 kN/sqm

Deff = 252 mm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 13 of 91

Beff = 2750 mm
SPu = 37.69 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 71.54 kNm
Ast Rqd = 1650 sqmm
Ast (min) = 1650 sqmm
Ast Prv (Distributed Across Total Width) = 11 - #16 @ 300
= 2211.66 sqmm

Top Steel Along L:


Ast Prv (Distributed Across Total Width) = 11 - #16 @ 300 c/c
= 2211.66 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 2: EZ) +0.5 (LOAD 7: RLL)
Pu = 243.31 kN
Mux = -19.11 kNm
Muy = -20.74 kNm
P/A = 32.17 kN/sqm
Mx/Zx = -5.51 kN/sqm
My/Zy = -5.98 kN/sqm

Deff = 236 mm
Leff = 2750 mm
SPu = 38.16 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 72.43 kNm
Ast Rqd = 1650 sqmm
Ast (min) = 1650 sqmm
Ast Prv (Distributed Across Total
= 11 - #16 @ 300
Length)
= 2211.66 sqmm

Top Steel Along B:


Ast Prv (Distributed Across Total
= 11 - #16 @ 300 c/c
Length)
= 2211.66 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 252 mm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 14 of 91

Critical Analysis Load Combination = 406


Critical Load Combination = [127] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 2: EZ) +0.5 (LOAD 7: RLL)
Pu = 243.31 kN
Mux = -19.11 kNm
Muy = -20.74 kNm
P/A = 32.17 kN/sqm
Mx/Zx = -5.51 kN/sqm
My/Zy = -5.98 kN/sqm

Deff = 252 mm
Beff = 2750 mm
SPu = 37.69 kN/sqm
Vu = SPu X (Loff - d) X B
= 95.66 kN
φVc = 461.08 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 236 mm
Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) -(LOAD 2: EZ) +0.5
(LOAD 7: RLL)
Pu = 243.31 kN
Mux = -19.11 kNm
Muy = -20.74 kNm
P/A = 32.17 kN/sqm
Mx/Zx = -5.51 kN/sqm
My/Zy = -5.98 kN/sqm

Deff = 236 mm
Leff = 2750 mm
SPu = 38.16 kN/sqm
Vu = SPu X (Boff - d) X L
= 98.53 kN
φVc = 433.14 kN
Vu < φVc

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 15 of 91

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 122 mm

Critical Analysis Load Combination = 406


Critical Load Combination = [127] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 2: EZ) +0.5 (LOAD 7: RLL)
Pu = 243.31 kN
Mux = -19.11 kNm
Muy = -20.74 kNm
P/A = 32.17 kN/sqm
Mx/Zx = -5.51 kN/sqm
My/Zy = -5.98 kN/sqm

Deff = 244 mm
Leff = 644 mm
Beff = 644 mm
Punching Perimeter = 2576 mm
Punching Area = 628544 sqmm
SPu = Average Pressure
= 32.17 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 229.97 kN
φVn = 1247.23 kN
φVc = 823.17 kN
No Shear
Vu < φVc Reinforcement
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) -(LOAD 2: EZ) +0.5
(LOAD 7: RLL)
Pu = 243.31 kN
A2 = 0.16 sqm
A1 = 2.56 sqm
Base Area = 7.56 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 4

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 16 of 91

Thus, Modification Factor = 2


Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 4950.4 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 14


Footing No : FC3
Column No : C3 ( 400 mm X 400 mm)
Analysis No : 34

Concrete Grade : C28


Steel Grade : Fy415
Clear Cover : 40 mm
Dfd : 1.5 m
Dw : 10 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 0 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 0 %

Design cross section by Consider : Average pressure


overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 3400mm X 3400mm X 300mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 86.7 kN
Soil Weight, S1 = 0 kN
Total Weight, W1 = F1 + S1
= 86.7 kN
Offset Along L (Loff) = 1500 mm
Offset Along B (Boff) = 1500 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 310

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 17 of 91

Critical Load Combination = [52] : (LOAD 3: DL1) +(LOAD 4: DL2) +


(LOAD 5: LL1) +(LOAD 6: LL2) +0.71 (LOAD
1: EX) +(LOAD 7: RLL)
Pcomb = 143.64 kN
P = Pcomb + W1
P = 230.34 kN
Mx = -7.79 kNm
My = -20.18 kNm
P/A = 19.93 kN/sqm
Mx/Zx = -1.19 kN/sqm
My/Zy = -3.08 kN/sqm
Maximum Soil Pressure = 24.2 kN/sqm
Allowable Soil Pressure = 1x200 kN/sqm
= 200 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 121
Critical Load Combination = [21] : 0.68 (LOAD 3: DL1)
+0.68 (LOAD 4: DL2) -
(LOAD 1: EX) +0.3 (LOAD
2: EZ)
Pcomb = 21.98 kN
P = Pcomb + W1 x 0.68
P = 80.94 kN
Mx = 16.09 kNm
My = 28.22 kNm
P/A = 7 kN/sqm
Mx/Zx = 2.46 kN/sqm
My/Zy = 4.31 kN/sqm
Minimum Soil Pressure = 0.24 kN/sqm
> 0

Check For Buoyancy:


Depth of Water Table is below Depth of Foundation, hence Buoyancy check Not Applicable

Check For Sliding:


Critical Analysis Load Combination = 122
[22] : 0.68 (LOAD 3: DL1) +0.68 (LOAD 4:
Critical Load Combination =
DL2) -(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Pcomb = 21.98 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 23.44 kN
shear Vy = 9.48 kN

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 18 of 91

Resultant sliding force = 25.28 kN


Downward force = Pcomb + (F1 + S1) x 0.68
= 80.94 kN
Upward water pressure = 0 kN
Net downward force = 80.94 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 32.38 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.28
> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 121
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 21.98 kN
Moment Mx = 16.09 kNm
P = Pcomb + (F1 + S1) x 0.68
= 80.94 kN
Stabilizing Moment for P = 137.6 kNm
DeStabilizing Moment = 16.09 kNm
Overturning Factor of safety = 8.55
Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 121
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 21.98 kN
Moment My = 28.22 kNm
P = Pcomb + (F1 + S1) x 0.68
= 80.94 kN
Stabilizing Moment for P = 137.6 kNm
DeStabilizing Moment = 28.22 kNm
Overturning Factor of safety = 4.88
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 19 of 91

Critical Analysis Load Combination = 404


Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 179.27 kN
Mux = -11.05 kNm
Muy = -28.32 kNm
P/A = 15.51 kN/sqm
Mx/Zx = -1.69 kN/sqm
My/Zy = -4.32 kN/sqm

Deff = 252 mm
Beff = 3400 mm
SPu = 17.19 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 65.77 kNm
Ast Rqd = 2040 sqmm
Ast (min) = 2040 sqmm
Ast Prv (Distributed Across Total Width) = 13 - #16 @ 300
= 2613.78 sqmm

Top Steel Along L:


Ast Prv (Distributed Across Total Width) = 13 - #16 @ 300 c/c
= 2613.78 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 179.27 kN
Mux = -11.05 kNm
Muy = -28.32 kNm
P/A = 15.51 kN/sqm
Mx/Zx = -1.69 kN/sqm
My/Zy = -4.32 kN/sqm

Deff = 236 mm
Leff = 3400 mm
SPu = 19.83 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 75.85 kNm
Ast Rqd = 2040 sqmm
Ast (min) = 2040 sqmm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 20 of 91

Ast Prv (Distributed Across Total


= 13 - #16 @ 300
Length)
= 2613.78 sqmm

Top Steel Along B:


Ast Prv (Distributed Across Total
= 13 - #16 @ 300 c/c
Length)
= 2613.78 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 252 mm
Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 179.27 kN
Mux = -11.05 kNm
Muy = -28.32 kNm
P/A = 15.51 kN/sqm
Mx/Zx = -1.69 kN/sqm
My/Zy = -4.32 kN/sqm

Deff = 252 mm
Beff = 3400 mm
SPu = 17.19 kN/sqm
Vu = SPu X (Loff - d) X B
= 72.96 kN
φVc = 570.06 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 236 mm
Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) +(LOAD 1: EX) +0.5
(LOAD 7: RLL)
Pu = 179.27 kN
Mux = -11.05 kNm
Muy = -28.32 kNm
P/A = 15.51 kN/sqm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 21 of 91

Mx/Zx = -1.69 kN/sqm


My/Zy = -4.32 kN/sqm

Deff = 236 mm
Leff = 3400 mm
SPu = 19.83 kN/sqm
Vu = SPu X (Boff - d) X L
= 85.23 kN
φVc = 535.52 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 122 mm

Critical Analysis Load Combination = 404


Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 179.27 kN
Mux = -11.05 kNm
Muy = -28.32 kNm
P/A = 15.51 kN/sqm
Mx/Zx = -1.69 kN/sqm
My/Zy = -4.32 kN/sqm

Deff = 244 mm
Leff = 644 mm
Beff = 644 mm
Punching Perimeter = 2576 mm
Punching Area = 628544 sqmm
SPu = Average Pressure
= 15.51 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 172.84 kN
φVn = 1247.23 kN
φVc = 823.17 kN
No Shear
Vu < φVc Reinforcement
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 404

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 22 of 91

Critical Load Combination = [125] : 1.2 (LOAD 3: DL1)


+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) +(LOAD 1: EX) +0.5
(LOAD 7: RLL)
Pu = 179.27 kN
A2 = 0.16 sqm
A1 = 2.56 sqm
Base Area = 11.56 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 4
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 4950.4 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 14


Footing No : FC4
Column No : C4 ( 400 mm X 400 mm)
Analysis No : 35

Concrete Grade : C28


Steel Grade : Fy415
Clear Cover : 40 mm
Dfd : 1.5 m
Dw : 10 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 0 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 0 %

Design cross section by Consider : Average pressure


overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 6400mm X 6400mm X 300mm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 23 of 91

Without considering Effect of Water


Table
Footing Self Wt., F1 = 307.2 kN
Soil Weight, S1 = 0 kN
Total Weight, W1 = F1 + S1
= 307.2 kN
Offset Along L (Loff) = 3000 mm
Offset Along B (Boff) = 3000 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 311
Critical Load Combination = [53] : (LOAD 3: DL1) +(LOAD 4: DL2) +
(LOAD 5: LL1) +(LOAD 6: LL2) -0.71 (LOAD
1: EX) +(LOAD 7: RLL)
Pcomb = 132.77 kN
P = Pcomb + W1
P = 439.97 kN
Mx = 19.53 kNm
My = -17.04 kNm
P/A = 10.74 kN/sqm
Mx/Zx = 0.45 kN/sqm
My/Zy = -0.39 kN/sqm
Maximum Soil Pressure = 11.58 kN/sqm
Allowable Soil Pressure = 1x200 kN/sqm
= 200 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 119
Critical Load Combination = [19] : 0.68 (LOAD 3: DL1)
+0.68 (LOAD 4: DL2) +
(LOAD 1: EX) +0.3 (LOAD
2: EZ)
Pcomb = -13.54 kN
P = Pcomb + W1 x 0.68
P = 195.35 kN
Mx = -26.45 kNm
My = 48.19 kNm
P/A = 4.77 kN/sqm
Mx/Zx = -0.61 kN/sqm
My/Zy = 1.1 kN/sqm
Minimum Soil Pressure = 3.06 kN/sqm
> 0

Check For Buoyancy:

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 24 of 91

Depth of Water Table is below Depth of Foundation, hence Buoyancy check Not Applicable

Check For Sliding:


Critical Analysis Load Combination = 123
[23] : 0.68 (LOAD 3: DL1) +0.68 (LOAD 4:
Critical Load Combination =
DL2) +0.3 (LOAD 1: EX) +(LOAD 2: EZ)
Pcomb = -8.63 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 65.99 kN
shear Vy = 1.66 kN
Resultant sliding force = 66.01 kN
Downward force = Pcomb + (F1 + S1) x 0.68
= 200.26 kN
Upward water pressure = 0 kN
Net downward force = 200.26 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 80.11 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.21
> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 119
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) +
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = -13.54 kN
Moment Mx = 26.45 kNm
P = Pcomb + (F1 + S1) x 0.68
= 195.35 kN
Stabilizing Moment for P = 625.13 kNm
DeStabilizing Moment = 26.45 kNm
Overturning Factor of safety = 23.64
Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 123
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2)
Critical Load Combination =
+0.3 (LOAD 1: EX) +(LOAD 2: EZ)
Factor of safety = 1.50

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 25 of 91

Pcomb = -8.63 kN
Moment My = 65.64 kNm
P = Pcomb + (F1 + S1) x 0.68
= 200.26 kN
Stabilizing Moment for P = 640.84 kNm
DeStabilizing Moment = 65.64 kNm
Overturning Factor of safety = 9.76
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 405
Critical Load Combination = [126] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 168.12 kN
Mux = 27.52 kNm
Muy = -24.79 kNm
P/A = 4.1 kN/sqm
Mx/Zx = 0.63 kN/sqm
My/Zy = -0.57 kN/sqm

Deff = 252 mm
Beff = 6400 mm
SPu = 4.73 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 136.35 kNm
Ast Rqd = 3840 sqmm
Ast (min) = 3840 sqmm
Ast Prv (Distributed Across Total Width) = 23 - #16 @ 300
= 4624.38 sqmm

Top Steel Along L:


Ast Prv (Distributed Across Total Width) = 23 - #16 @ 300 c/c
= 4624.38 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 2: EZ) +0.5 (LOAD 7: RLL)
Pu = 161.1 kN
Mux = -4.18 kNm
Muy = -49.72 kNm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 26 of 91

P/A = 3.93 kN/sqm


Mx/Zx = -0.1 kN/sqm
My/Zy = -1.14 kN/sqm

Deff = 236 mm
Leff = 6400 mm
SPu = 5.07 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 146.05 kNm
Ast Rqd = 3840 sqmm
Ast (min) = 3840 sqmm
Ast Prv (Distributed Across Total
= 23 - #16 @ 300
Length)
= 4624.38 sqmm

Top Steel Along B:


Ast Prv (Distributed Across Total
= 23 - #16 @ 300 c/c
Length)
= 4624.38 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 252 mm
Critical Analysis Load Combination = 405
Critical Load Combination = [126] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 168.12 kN
Mux = 27.52 kNm
Muy = -24.79 kNm
P/A = 4.1 kN/sqm
Mx/Zx = 0.63 kN/sqm
My/Zy = -0.57 kN/sqm

Deff = 252 mm
Beff = 6400 mm
SPu = 4.73 kN/sqm
Vu = SPu X (Loff - d) X B
= 83.26 kN
φVc = 1073.06 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 27 of 91

= 236 mm
Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) -(LOAD 2: EZ) +0.5
(LOAD 7: RLL)
Pu = 161.1 kN
Mux = -4.18 kNm
Muy = -49.72 kNm
P/A = 3.93 kN/sqm
Mx/Zx = -0.1 kN/sqm
My/Zy = -1.14 kN/sqm

Deff = 236 mm
Leff = 6400 mm
SPu = 5.07 kN/sqm
Vu = SPu X (Boff - d) X L
= 89.71 kN
φVc = 1008.03 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 122 mm

Critical Analysis Load Combination = 405


Critical Load Combination = [126] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 168.12 kN
Mux = 27.52 kNm
Muy = -24.79 kNm
P/A = 4.1 kN/sqm
Mx/Zx = 0.63 kN/sqm
My/Zy = -0.57 kN/sqm

Deff = 244 mm
Leff = 644 mm
Beff = 644 mm
Punching Perimeter = 2576 mm
Punching Area = 628544 sqmm
SPu = Average Pressure

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 28 of 91

= 4.1 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 166.41 kN
φVn = 1247.23 kN
φVc = 823.17 kN
No Shear
Vu < φVc Reinforcement
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 405
Critical Load Combination = [126] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) -(LOAD 1: EX) +0.5
(LOAD 7: RLL)
Pu = 168.12 kN
A2 = 0.16 sqm
A1 = 2.56 sqm
Base Area = 40.96 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 4
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 4950.4 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 14


Footing No : FC5
Column No : C5 ( 300 mm X 400 mm)
Analysis No : 36

Concrete Grade : C28


Steel Grade : Fy415
Clear Cover : 40 mm
Dfd : 1.5 m
Dw : 10 m

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 29 of 91

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 0 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 0 %

Design cross section by Consider : Average pressure


overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 2050mm X 1950mm X 300mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 29.98 kN
Soil Weight, S1 = 0 kN
Total Weight, W1 = F1 + S1
= 29.98 kN
Offset Along L (Loff) = 825 mm
Offset Along B (Boff) = 825 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 312
Critical Load Combination = [54] : (LOAD 3: DL1) +(LOAD 4: DL2) +
(LOAD 5: LL1) +(LOAD 6: LL2) +0.71 (LOAD
2: EZ) +(LOAD 7: RLL)
Pcomb = 191.96 kN
P = Pcomb + W1
P = 221.94 kN
Mx = 2.73 kNm
My = 16.11 kNm
P/A = 55.52 kN/sqm
Mx/Zx = 2 kN/sqm
My/Zy = 12.4 kN/sqm
Maximum Soil Pressure = 69.92 kN/sqm
Allowable Soil Pressure = 1x200 kN/sqm
= 200 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 126
Critical Load Combination = [26] : 0.68 (LOAD 3: DL1)
+0.68 (LOAD 4: DL2) -0.3
(LOAD 1: EX) -(LOAD 2:
EZ)

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 30 of 91

Pcomb = 75.74 kN
P = Pcomb + W1 x 0.68
P = 96.12 kN
Mx = 5.53 kNm
My = -25.36 kNm
P/A = 24.05 kN/sqm
Mx/Zx = 4.05 kN/sqm
My/Zy = -19.52 kN/sqm
Minimum Soil Pressure = 0.48 kN/sqm
> 0

Check For Buoyancy:


Depth of Water Table is below Depth of Foundation, hence Buoyancy check Not Applicable

Check For Sliding:


Critical Analysis Load Combination = 126
[26] : 0.68 (LOAD 3: DL1) +0.68 (LOAD 4:
Critical Load Combination =
DL2) -0.3 (LOAD 1: EX) -(LOAD 2: EZ)
Pcomb = 75.74 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 31.17 kN
shear Vy = 5.41 kN
Resultant sliding force = 31.64 kN
Downward force = Pcomb + (F1 + S1) x 0.68
= 96.12 kN
Upward water pressure = 0 kN
Net downward force = 96.12 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 38.45 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.22
> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 121
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 106.65 kN
Moment Mx = 25.67 kNm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 31 of 91

P = Pcomb + (F1 + S1) x 0.68


= 127.04 kN
Stabilizing Moment for P = 130.22 kNm
DeStabilizing Moment = 25.67 kNm
Overturning Factor of safety = 5.07
Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 126
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -0.3
Critical Load Combination =
(LOAD 1: EX) -(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 75.74 kN
Moment My = 25.36 kNm
P = Pcomb + (F1 + S1) x 0.68
= 96.12 kN
Stabilizing Moment for P = 93.72 kNm
DeStabilizing Moment = 25.36 kNm
Overturning Factor of safety = 3.7
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 219.72 kN
Mux = -23.06 kNm
Muy = 7.7 kNm
P/A = 54.96 kN/sqm
Mx/Zx = -16.88 kN/sqm
My/Zy = 5.93 kN/sqm

Deff = 252 mm
Beff = 1950 mm
SPu = 71.85 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 47.68 kNm
Ast Rqd = 1170 sqmm
Ast (min) = 1170 sqmm
Ast Prv (Distributed Across Total Width) = 8 - #16 @ 300
= 1608.48 sqmm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 32 of 91

Top Steel Along L:


Ast Prv (Distributed Across Total Width) = 8 - #16 @ 300 c/c
= 1608.48 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 410
Critical Load Combination = [131] : 0.9 (LOAD 3: DL1) +0.9 (LOAD 4:
DL2) +(LOAD 2: EZ)
Pu = 184.81 kN
Mux = 3.33 kNm
Muy = 22.77 kNm
P/A = 46.23 kN/sqm
Mx/Zx = 2.44 kN/sqm
My/Zy = 17.52 kN/sqm

Deff = 236 mm
Leff = 2050 mm
SPu = 63.76 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 44.48 kNm
Ast Rqd = 1230 sqmm
Ast (min) = 1230 sqmm
Ast Prv (Distributed Across Total
= 8 - #16 @ 300
Length)
= 1608.48 sqmm

Top Steel Along B:


Ast Prv (Distributed Across Total
= 8 - #16 @ 300 c/c
Length)
= 1608.48 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 252 mm
Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 219.72 kN
Mux = -23.06 kNm
Muy = 7.7 kNm
P/A = 54.96 kN/sqm
Mx/Zx = -16.88 kN/sqm
My/Zy = 5.93 kN/sqm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 33 of 91

Deff = 252 mm
Beff = 1950 mm
SPu = 71.85 kN/sqm
Vu = SPu X (Loff - d) X B
= 80.28 kN
φVc = 326.95 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 236 mm
Critical Analysis Load Combination = 410
Critical Load Combination = [131] : 0.9 (LOAD 3: DL1)
+0.9 (LOAD 4: DL2) +
(LOAD 2: EZ)
Pu = 184.81 kN
Mux = 3.33 kNm
Muy = 22.77 kNm
P/A = 46.23 kN/sqm
Mx/Zx = 2.44 kN/sqm
My/Zy = 17.52 kN/sqm

Deff = 236 mm
Leff = 2050 mm
SPu = 63.76 kN/sqm
Vu = SPu X (Boff - d) X L
= 76.98 kN
φVc = 322.89 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 122 mm

Critical Analysis Load Combination = 401


Critical Load Combination = [122] : 1.4 (LOAD 3: DL1) +1.4 (LOAD 4:
DL2)
Pu = 235.59 kN
Mux = 1.4 kNm
Muy = -0.2 kNm
P/A = 58.93 kN/sqm
Mx/Zx = 1.03 kN/sqm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 34 of 91

My/Zy = -0.16 kN/sqm

Deff = 244 mm
Leff = 644 mm
Beff = 544 mm
Punching Perimeter = 2376 mm
Punching Area = 579744 sqmm
SPu = Average Pressure
= 58.93 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 214.94 kN
φVn = 1150.39 kN
φVc = 759.26 kN
No Shear
Vu < φVc Reinforcement
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 401
Critical Load Combination = [122] : 1.4 (LOAD 3: DL1)
+1.4 (LOAD 4: DL2)
Pu = 235.59 kN
A2 = 0.12 sqm
A1 = 2.4 sqm
Base Area = 4 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 4.4721
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 3712.8 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 14


Footing No : FC6
Column No : C6 ( 300 mm X 300 mm)
Analysis No : 37

Concrete Grade : C28

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 35 of 91

Steel Grade : Fy415


Clear Cover : 40 mm
Dfd : 1.5 m
Dw : 10 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 0 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 0 %

Design cross section by Consider : Average pressure


overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 1350mm X 1350mm X 300mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 13.67 kN
Soil Weight, S1 = 0 kN
Total Weight, W1 = F1 + S1
= 13.67 kN
Offset Along L (Loff) = 525 mm
Offset Along B (Boff) = 525 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 311
Critical Load Combination = [53] : (LOAD 3: DL1) +(LOAD 4: DL2) +
(LOAD 5: LL1) +(LOAD 6: LL2) -0.71 (LOAD
1: EX) +(LOAD 7: RLL)
Pcomb = 154.69 kN
P = Pcomb + W1
P = 168.36 kN
Mx = 10.68 kNm
My = 2.87 kNm
P/A = 92.38 kN/sqm
Mx/Zx = 26.04 kN/sqm
My/Zy = 7 kN/sqm
Maximum Soil Pressure = 125.42 kN/sqm
Allowable Soil Pressure = 1x200 kN/sqm
= 200 kN/sqm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 36 of 91

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 120
Critical Load Combination = [20] : 0.68 (LOAD 3: DL1)
+0.68 (LOAD 4: DL2) +
(LOAD 1: EX) -0.3 (LOAD
2: EZ)
Pcomb = 88.57 kN
P = Pcomb + W1 x 0.68
P = 97.86 kN
Mx = -14.75 kNm
My = -6.62 kNm
P/A = 53.7 kN/sqm
Mx/Zx = -35.97 kN/sqm
My/Zy = -16.14 kN/sqm
Minimum Soil Pressure = 1.59 kN/sqm
> 0

Check For Buoyancy:


Depth of Water Table is below Depth of Foundation, hence Buoyancy check Not Applicable

Check For Sliding:


Critical Analysis Load Combination = 120
[20] : 0.68 (LOAD 3: DL1) +0.68 (LOAD 4:
Critical Load Combination =
DL2) +(LOAD 1: EX) -0.3 (LOAD 2: EZ)
Pcomb = 88.57 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 8.41 kN
shear Vy = 18.05 kN
Resultant sliding force = 19.92 kN
Downward force = Pcomb + (F1 + S1) x 0.68
= 97.86 kN
Upward water pressure = 0 kN
Net downward force = 97.86 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 39.15 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.97
> 1.2

Check For Overturning:


Along Width:

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 37 of 91

Critical Analysis Load Combination = 120


0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) +
Critical Load Combination =
(LOAD 1: EX) -0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 88.57 kN
Moment Mx = 14.75 kNm
P = Pcomb + (F1 + S1) x 0.68
= 97.86 kN
Stabilizing Moment for P = 66.06 kNm
DeStabilizing Moment = 14.75 kNm
Overturning Factor of safety = 4.48
Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 125
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2)
Critical Load Combination =
+0.3 (LOAD 1: EX) -(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 79.16 kN
Moment My = 11.27 kNm
P = Pcomb + (F1 + S1) x 0.68
= 88.46 kN
Stabilizing Moment for P = 59.71 kNm
DeStabilizing Moment = 11.27 kNm
Overturning Factor of safety = 5.3
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 405
Critical Load Combination = [126] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 186.68 kN
Mux = 14.97 kNm
Muy = 3.99 kNm
P/A = 102.43 kN/sqm
Mx/Zx = 36.51 kN/sqm
My/Zy = 9.73 kN/sqm

Deff = 252 mm
Beff = 1350 mm
SPu = 138.94 kN/sqm
Mu = SPu X B X Loff X Loff / 2

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 38 of 91

= 25.85 kNm
Ast Rqd = 810 sqmm
Ast (min) = 810 sqmm
Ast Prv (Distributed Across Total Width) = 6 - #16 @ 300
= 1206.36 sqmm

Top Steel Along L:


Ast Prv (Distributed Across Total Width) = 6 - #16 @ 300 c/c
= 1206.36 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 401
Critical Load Combination = [122] : 1.4 (LOAD 3: DL1) +1.4 (LOAD 4:
DL2)
Pu = 209.55 kN
Mux = 0.44 kNm
Muy = 0.35 kNm
P/A = 114.98 kN/sqm
Mx/Zx = 1.07 kN/sqm
My/Zy = 0.86 kN/sqm

Deff = 236 mm
Leff = 1350 mm
SPu = 115.84 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 21.55 kNm
Ast Rqd = 810 sqmm
Ast (min) = 810 sqmm
Ast Prv (Distributed Across Total
= 6 - #16 @ 300
Length)
= 1206.36 sqmm

Top Steel Along B:


Ast Prv (Distributed Across Total
= 6 - #16 @ 300 c/c
Length)
= 1206.36 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 252 mm
Critical Analysis Load Combination = 405
Critical Load Combination = [126] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 1: EX) +0.5 (LOAD 7: RLL)

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 39 of 91

Pu = 186.68 kN
Mux = 14.97 kNm
Muy = 3.99 kNm
P/A = 102.43 kN/sqm
Mx/Zx = 36.51 kN/sqm
My/Zy = 9.73 kN/sqm

Deff = 252 mm
Beff = 1350 mm
SPu = 138.94 kN/sqm
Vu = SPu X (Loff - d) X B
= 51.21 kN
φVc = 235.09 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 236 mm
Critical Analysis Load Combination = 401
Critical Load Combination = [122] : 1.4 (LOAD 3: DL1)
+1.4 (LOAD 4: DL2)
Pu = 209.55 kN
Mux = 0.44 kNm
Muy = 0.35 kNm
P/A = 114.98 kN/sqm
Mx/Zx = 1.07 kN/sqm
My/Zy = 0.86 kN/sqm

Deff = 236 mm
Leff = 1350 mm
SPu = 115.84 kN/sqm
Vu = SPu X (Boff - d) X L
= 45.2 kN
φVc = 219.17 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 122 mm

Critical Analysis Load Combination = 401


Critical Load Combination = [122] : 1.4 (LOAD 3: DL1) +1.4 (LOAD 4:
DL2)

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 40 of 91

Pu = 209.55 kN
Mux = 0.44 kNm
Muy = 0.35 kNm
P/A = 114.98 kN/sqm
Mx/Zx = 1.07 kN/sqm
My/Zy = 0.86 kN/sqm

Deff = 244 mm
Leff = 544 mm
Beff = 544 mm
Punching Perimeter = 2176 mm
Punching Area = 530944 sqmm
SPu = Average Pressure
= 114.98 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 175.53 kN
φVn = 1053.56 kN
φVc = 695.35 kN
No Shear
Vu < φVc Reinforcement
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 401
Critical Load Combination = [122] : 1.4 (LOAD 3: DL1)
+1.4 (LOAD 4: DL2)
Pu = 209.55 kN
A2 = 0.09 sqm
A1 = 2.25 sqm
Base Area = 1.82 sqm
A1 > Base Area
Thus, A1 = 1.82
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 4.4969
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 2784.6 kN
Φ1Pnb > Pu, Hence Safe.

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 41 of 91

Design Code : ACI 318M - 14


Footing No : FC7
Column No : C7 ( 300 mm X 400 mm)
Analysis No : 38

Concrete Grade : C28


Steel Grade : Fy415
Clear Cover : 40 mm
Dfd : 1.5 m
Dw : 10 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 0 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 0 %

Design cross section by Consider : Average pressure


overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 2700mm X 2600mm X 300mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 52.65 kN
Soil Weight, S1 = 0 kN
Total Weight, W1 = F1 + S1
= 52.65 kN
Offset Along L (Loff) = 1150 mm
Offset Along B (Boff) = 1150 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 310
Critical Load Combination = [52] : (LOAD 3: DL1) +(LOAD 4: DL2) +
(LOAD 5: LL1) +(LOAD 6: LL2) +0.71 (LOAD
1: EX) +(LOAD 7: RLL)
Pcomb = 127.21 kN
P = Pcomb + W1
P = 179.86 kN
Mx = -15.16 kNm
My = -12.87 kNm
P/A = 25.62 kN/sqm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 42 of 91

Mx/Zx = -4.8 kN/sqm


My/Zy = -4.23 kN/sqm
Maximum Soil Pressure = 34.65 kN/sqm
Allowable Soil Pressure = 1x200 kN/sqm
= 200 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 121
Critical Load Combination = [21] : 0.68 (LOAD 3: DL1)
+0.68 (LOAD 4: DL2) -
(LOAD 1: EX) +0.3 (LOAD
2: EZ)
Pcomb = 57.16 kN
P = Pcomb + W1 x 0.68
P = 92.96 kN
Mx = 21.57 kNm
My = 18.87 kNm
P/A = 13.24 kN/sqm
Mx/Zx = 6.83 kN/sqm
My/Zy = 6.2 kN/sqm
Minimum Soil Pressure = 0.21 kN/sqm
> 0

Check For Buoyancy:


Depth of Water Table is below Depth of Foundation, hence Buoyancy check Not Applicable

Check For Sliding:


Critical Analysis Load Combination = 122
[22] : 0.68 (LOAD 3: DL1) +0.68 (LOAD 4:
Critical Load Combination =
DL2) -(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Pcomb = 57.16 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 24.06 kN
shear Vy = 14.57 kN
Resultant sliding force = 28.13 kN
Downward force = Pcomb + (F1 + S1) x 0.68
= 92.96 kN
Upward water pressure = 0 kN
Net downward force = 92.96 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 37.19 kN
Factor of safety available = Resisting Force / Sliding

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 43 of 91

Force
= 1.32
> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 121
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 57.16 kN
Moment Mx = 21.57 kNm
P = Pcomb + (F1 + S1) x 0.68
= 92.96 kN
Stabilizing Moment for P = 125.5 kNm
DeStabilizing Moment = 21.57 kNm
Overturning Factor of safety = 5.82
Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 121
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 57.16 kN
Moment My = 18.87 kNm
P = Pcomb + (F1 + S1) x 0.68
= 92.96 kN
Stabilizing Moment for P = 120.85 kNm
DeStabilizing Moment = 18.87 kNm
Overturning Factor of safety = 6.41
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 155.52 kN
Mux = -21.32 kNm
Muy = -18.13 kNm
P/A = 22.15 kN/sqm
Mx/Zx = -6.75 kN/sqm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 44 of 91

My/Zy = -5.96 kN/sqm

Deff = 252 mm
Beff = 2600 mm
SPu = 28.9 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 49.69 kNm
Ast Rqd = 1560 sqmm
Ast (min) = 1560 sqmm
Ast Prv (Distributed Across Total Width) = 10 - #16 @ 300
= 2010.6 sqmm

Top Steel Along L:


Ast Prv (Distributed Across Total Width) = 10 - #16 @ 300 c/c
= 2010.6 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 155.52 kN
Mux = -21.32 kNm
Muy = -18.13 kNm
P/A = 22.15 kN/sqm
Mx/Zx = -6.75 kN/sqm
My/Zy = -5.96 kN/sqm

Deff = 236 mm
Leff = 2700 mm
SPu = 28.11 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 50.19 kNm
Ast Rqd = 1620 sqmm
Ast (min) = 1620 sqmm
Ast Prv (Distributed Across Total
= 10 - #16 @ 300
Length)
= 2010.6 sqmm

Top Steel Along B:


Ast Prv (Distributed Across Total
= 10 - #16 @ 300 c/c
Length)
= 2010.6 sqmm
Design For Shear:

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 45 of 91

One Way Shear Along L:


Critical Section @ d from Column Face
= 252 mm
Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 155.52 kN
Mux = -21.32 kNm
Muy = -18.13 kNm
P/A = 22.15 kN/sqm
Mx/Zx = -6.75 kN/sqm
My/Zy = -5.96 kN/sqm

Deff = 252 mm
Beff = 2600 mm
SPu = 28.9 kN/sqm
Vu = SPu X (Loff - d) X B
= 67.48 kN
φVc = 435.93 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 236 mm
Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) +(LOAD 1: EX) +0.5
(LOAD 7: RLL)
Pu = 155.52 kN
Mux = -21.32 kNm
Muy = -18.13 kNm
P/A = 22.15 kN/sqm
Mx/Zx = -6.75 kN/sqm
My/Zy = -5.96 kN/sqm

Deff = 236 mm
Leff = 2700 mm
SPu = 28.11 kN/sqm
Vu = SPu X (Boff - d) X L
= 69.38 kN

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 46 of 91

φVc = 425.26 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 122 mm

Critical Analysis Load Combination = 401


Critical Load Combination = [122] : 1.4 (LOAD 3: DL1) +1.4 (LOAD 4:
DL2)
Pu = 158.83 kN
Mux = -0.22 kNm
Muy = 0.03 kNm
P/A = 22.63 kN/sqm
Mx/Zx = -0.07 kN/sqm
My/Zy = 0.01 kN/sqm

Deff = 244 mm
Leff = 644 mm
Beff = 544 mm
Punching Perimeter = 2376 mm
Punching Area = 579744 sqmm
SPu = Average Pressure
= 22.63 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 150.91 kN
φVn = 1150.39 kN
φVc = 759.26 kN
No Shear
Vu < φVc Reinforcement
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 401
Critical Load Combination = [122] : 1.4 (LOAD 3: DL1)
+1.4 (LOAD 4: DL2)
Pu = 158.83 kN
A2 = 0.12 sqm
A1 = 2.4 sqm
Base Area = 7.02 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 4.4721

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 47 of 91

Thus, Modification Factor = 2


Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 3712.8 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 14


Footing No : FC8
Column No : C8 ( 300 mm X 300 mm)
Analysis No : 39

Concrete Grade : C28


Steel Grade : Fy415
Clear Cover : 40 mm
Dfd : 1.5 m
Dw : 10 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 0 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 0 %

Design cross section by Consider : Average pressure


overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 1400mm X 1400mm X 300mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 14.7 kN
Soil Weight, S1 = 0 kN
Total Weight, W1 = F1 + S1
= 14.7 kN
Offset Along L (Loff) = 550 mm
Offset Along B (Boff) = 550 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 311

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 48 of 91

Critical Load Combination = [53] : (LOAD 3: DL1) +(LOAD 4: DL2) +


(LOAD 5: LL1) +(LOAD 6: LL2) -0.71 (LOAD
1: EX) +(LOAD 7: RLL)
Pcomb = 162.09 kN
P = Pcomb + W1
P = 176.79 kN
Mx = 14.29 kNm
My = 2.37 kNm
P/A = 90.2 kN/sqm
Mx/Zx = 31.24 kN/sqm
My/Zy = 5.18 kN/sqm
Maximum Soil Pressure = 126.62 kN/sqm
Allowable Soil Pressure = 1x200 kN/sqm
= 200 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 120
Critical Load Combination = [20] : 0.68 (LOAD 3: DL1)
+0.68 (LOAD 4: DL2) +
(LOAD 1: EX) -0.3 (LOAD
2: EZ)
Pcomb = 95.59 kN
P = Pcomb + W1 x 0.68
P = 105.59 kN
Mx = -17.08 kNm
My = -7.23 kNm
P/A = 53.87 kN/sqm
Mx/Zx = -37.34 kN/sqm
My/Zy = -15.82 kN/sqm
Minimum Soil Pressure = 0.72 kN/sqm
> 0

Check For Buoyancy:


Depth of Water Table is below Depth of Foundation, hence Buoyancy check Not Applicable

Check For Sliding:


Critical Analysis Load Combination = 119
[19] : 0.68 (LOAD 3: DL1) +0.68 (LOAD 4:
Critical Load Combination =
DL2) +(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Pcomb = 91.6 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 2.11 kN
shear Vy = 21.57 kN

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 49 of 91

Resultant sliding force = 21.67 kN


Downward force = Pcomb + (F1 + S1) x 0.68
= 101.6 kN
Upward water pressure = 0 kN
Net downward force = 101.6 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 40.64 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.88
> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 119
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) +
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 91.6 kN
Moment Mx = 18.49 kNm
P = Pcomb + (F1 + S1) x 0.68
= 101.6 kN
Stabilizing Moment for P = 71.12 kNm
DeStabilizing Moment = 18.49 kNm
Overturning Factor of safety = 3.85
Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 124
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -0.3
Critical Load Combination =
(LOAD 1: EX) +(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 101.52 kN
Moment My = 10.84 kNm
P = Pcomb + (F1 + S1) x 0.68
= 111.52 kN
Stabilizing Moment for P = 78.06 kNm
DeStabilizing Moment = 10.84 kNm
Overturning Factor of safety = 7.2
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 50 of 91

Critical Analysis Load Combination = 405


Critical Load Combination = [126] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 196.17 kN
Mux = 19.89 kNm
Muy = 3.43 kNm
P/A = 100.09 kN/sqm
Mx/Zx = 43.49 kN/sqm
My/Zy = 7.49 kN/sqm

Deff = 252 mm
Beff = 1400 mm
SPu = 143.58 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 30.4 kNm
Ast Rqd = 840 sqmm
Ast (min) = 840 sqmm
Ast Prv (Distributed Across Total Width) = 6 - #16 @ 300
= 1206.36 sqmm

Top Steel Along L:


Ast Prv (Distributed Across Total Width) = 6 - #16 @ 300 c/c
= 1206.36 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 2: EZ) +0.5 (LOAD 7: RLL)
Pu = 191.61 kN
Mux = 3.7 kNm
Muy = -10.48 kNm
P/A = 97.76 kN/sqm
Mx/Zx = 8.09 kN/sqm
My/Zy = -22.9 kN/sqm

Deff = 236 mm
Leff = 1400 mm
SPu = 120.66 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 25.55 kNm
Ast Rqd = 840 sqmm
Ast (min) = 840 sqmm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 51 of 91

Ast Prv (Distributed Across Total


= 6 - #16 @ 300
Length)
= 1206.36 sqmm

Top Steel Along B:


Ast Prv (Distributed Across Total
= 6 - #16 @ 300 c/c
Length)
= 1206.36 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 252 mm
Critical Analysis Load Combination = 405
Critical Load Combination = [126] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 196.17 kN
Mux = 19.89 kNm
Muy = 3.43 kNm
P/A = 100.09 kN/sqm
Mx/Zx = 43.49 kN/sqm
My/Zy = 7.49 kN/sqm

Deff = 252 mm
Beff = 1400 mm
SPu = 143.58 kN/sqm
Vu = SPu X (Loff - d) X B
= 59.9 kN
φVc = 242.13 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 236 mm
Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) -(LOAD 2: EZ) +0.5
(LOAD 7: RLL)
Pu = 191.61 kN
Mux = 3.7 kNm
Muy = -10.48 kNm
P/A = 97.76 kN/sqm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 52 of 91

Mx/Zx = 8.09 kN/sqm


My/Zy = -22.9 kN/sqm

Deff = 236 mm
Leff = 1400 mm
SPu = 120.66 kN/sqm
Vu = SPu X (Boff - d) X L
= 53.04 kN
φVc = 225.9 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 122 mm

Critical Analysis Load Combination = 401


Critical Load Combination = [122] : 1.4 (LOAD 3: DL1) +1.4 (LOAD 4:
DL2)
Pu = 215.78 kN
Mux = 1.57 kNm
Muy = -0.61 kNm
P/A = 110.09 kN/sqm
Mx/Zx = 3.43 kN/sqm
My/Zy = -1.34 kN/sqm

Deff = 244 mm
Leff = 544 mm
Beff = 544 mm
Punching Perimeter = 2176 mm
Punching Area = 530944 sqmm
SPu = Average Pressure
= 110.09 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 183.2 kN
φVn = 1053.56 kN
φVc = 695.35 kN
No Shear
Vu < φVc Reinforcement
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 401
Critical Load Combination = [122] : 1.4 (LOAD 3: DL1)

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 53 of 91

+1.4 (LOAD 4: DL2)


Pu = 215.78 kN
A2 = 0.09 sqm
A1 = 2.25 sqm
Base Area = 1.96 sqm
A1 > Base Area
Thus, A1 = 1.96
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 4.6667
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 2784.6 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 14


Footing No : FC9
Column No : C9 ( 300 mm X 400 mm)
Analysis No : 40

Concrete Grade : C28


Steel Grade : Fy415
Clear Cover : 40 mm
Dfd : 1.5 m
Dw : 10 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 0 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 0 %

Design cross section by Consider : Average pressure


overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 2800mm X 2700mm X 300mm
Without considering Effect of Water
Table

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 54 of 91

Footing Self Wt., F1 = 56.7 kN


Soil Weight, S1 = 0 kN
Total Weight, W1 = F1 + S1
= 56.7 kN
Offset Along L (Loff) = 1200 mm
Offset Along B (Boff) = 1200 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 310
Critical Load Combination = [52] : (LOAD 3: DL1) +(LOAD 4: DL2) +
(LOAD 5: LL1) +(LOAD 6: LL2) +0.71 (LOAD
1: EX) +(LOAD 7: RLL)
Pcomb = 142.75 kN
P = Pcomb + W1
P = 199.45 kN
Mx = -20.11 kNm
My = -13.05 kNm
P/A = 26.38 kN/sqm
Mx/Zx = -5.7 kN/sqm
My/Zy = -3.84 kN/sqm
Maximum Soil Pressure = 35.92 kN/sqm
Allowable Soil Pressure = 1x200 kN/sqm
= 200 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 121
Critical Load Combination = [21] : 0.68 (LOAD 3: DL1)
+0.68 (LOAD 4: DL2) -
(LOAD 1: EX) +0.3 (LOAD
2: EZ)
Pcomb = 60.23 kN
P = Pcomb + W1 x 0.68
P = 98.78 kN
Mx = 26.55 kNm
My = 18.5 kNm
P/A = 13.07 kN/sqm
Mx/Zx = 7.52 kN/sqm
My/Zy = 5.44 kN/sqm
Minimum Soil Pressure = 0.1 kN/sqm
> 0

Check For Buoyancy:


Depth of Water Table is below Depth of Foundation, hence Buoyancy check Not Applicable

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 55 of 91

Check For Sliding:


Critical Analysis Load Combination = 122
[22] : 0.68 (LOAD 3: DL1) +0.68 (LOAD 4:
Critical Load Combination =
DL2) -(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Pcomb = 60.23 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 23.3 kN
shear Vy = 17.85 kN
Resultant sliding force = 29.35 kN
Downward force = Pcomb + (F1 + S1) x 0.68
= 98.78 kN
Upward water pressure = 0 kN
Net downward force = 98.78 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 39.51 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.35
> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 121
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 60.23 kN
Moment Mx = 26.55 kNm
P = Pcomb + (F1 + S1) x 0.68
= 98.78 kN
Stabilizing Moment for P = 138.29 kNm
DeStabilizing Moment = 26.55 kNm
Overturning Factor of safety = 5.21
Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 121
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 60.23 kN
Moment My = 18.5 kNm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 56 of 91

P = Pcomb + (F1 + S1) x 0.68


= 98.78 kN
Stabilizing Moment for P = 133.36 kNm
DeStabilizing Moment = 18.5 kNm
Overturning Factor of safety = 7.21
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 175.11 kN
Mux = -28.25 kNm
Muy = -18.33 kNm
P/A = 23.16 kN/sqm
Mx/Zx = -8.01 kN/sqm
My/Zy = -5.39 kN/sqm

Deff = 252 mm
Beff = 2700 mm
SPu = 31.17 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 60.6 kNm
Ast Rqd = 1620 sqmm
Ast (min) = 1620 sqmm
Ast Prv (Distributed Across Total Width) = 10 - #16 @ 300
= 2010.6 sqmm

Top Steel Along L:


Ast Prv (Distributed Across Total Width) = 10 - #16 @ 300 c/c
= 2010.6 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 175.11 kN
Mux = -28.25 kNm
Muy = -18.33 kNm
P/A = 23.16 kN/sqm
Mx/Zx = -8.01 kN/sqm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 57 of 91

My/Zy = -5.39 kN/sqm

Deff = 236 mm
Leff = 2800 mm
SPu = 28.55 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 57.56 kNm
Ast Rqd = 1680 sqmm
Ast (min) = 1680 sqmm
Ast Prv (Distributed Across Total
= 11 - #16 @ 300
Length)
= 2211.66 sqmm

Top Steel Along B:


Ast Prv (Distributed Across Total
= 11 - #16 @ 300 c/c
Length)
= 2211.66 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 252 mm
Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 175.11 kN
Mux = -28.25 kNm
Muy = -18.33 kNm
P/A = 23.16 kN/sqm
Mx/Zx = -8.01 kN/sqm
My/Zy = -5.39 kN/sqm

Deff = 252 mm
Beff = 2700 mm
SPu = 31.17 kN/sqm
Vu = SPu X (Loff - d) X B
= 79.79 kN
φVc = 452.7 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 236 mm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 58 of 91

Critical Analysis Load Combination = 404


Critical Load Combination = [125] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) +(LOAD 1: EX) +0.5
(LOAD 7: RLL)
Pu = 175.11 kN
Mux = -28.25 kNm
Muy = -18.33 kNm
P/A = 23.16 kN/sqm
Mx/Zx = -8.01 kN/sqm
My/Zy = -5.39 kN/sqm

Deff = 236 mm
Leff = 2800 mm
SPu = 28.55 kN/sqm
Vu = SPu X (Boff - d) X L
= 77.06 kN
φVc = 441.01 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 122 mm

Critical Analysis Load Combination = 404


Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 175.11 kN
Mux = -28.25 kNm
Muy = -18.33 kNm
P/A = 23.16 kN/sqm
Mx/Zx = -8.01 kN/sqm
My/Zy = -5.39 kN/sqm

Deff = 244 mm
Leff = 644 mm
Beff = 544 mm
Punching Perimeter = 2376 mm
Punching Area = 579744 sqmm
SPu = Average Pressure
= 23.16 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 59 of 91

= 167 kN
φVn = 1150.39 kN
φVc = 759.26 kN
No Shear
Vu < φVc Reinforcement
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) +(LOAD 1: EX) +0.5
(LOAD 7: RLL)
Pu = 175.11 kN
A2 = 0.12 sqm
A1 = 2.4 sqm
Base Area = 7.56 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 4.4721
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 3712.8 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 14


Footing No : FC10
Column No : C10 ( 400 mm X 400 mm)
Analysis No : 41

Concrete Grade : C28


Steel Grade : Fy415
Clear Cover : 40 mm
Dfd : 1.5 m
Dw : 10 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 0 %

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 60 of 91

Permissible SBC Increase for Wind = 0 %


Live Load Reduction = 0 %
Permissible area of loss of contact = 0 %

Design cross section by Consider : Average pressure


overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 5500mm X 5500mm X 300mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 226.87 kN
Soil Weight, S1 = 0 kN
Total Weight, W1 = F1 + S1
= 226.88 kN
Offset Along L (Loff) = 2550 mm
Offset Along B (Boff) = 2550 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 312
Critical Load Combination = [54] : (LOAD 3: DL1) +(LOAD 4: DL2) +
(LOAD 5: LL1) +(LOAD 6: LL2) +0.71 (LOAD
2: EZ) +(LOAD 7: RLL)
Pcomb = 134.15 kN
P = Pcomb + W1
P = 361.02 kN
Mx = -7.53 kNm
My = 34.51 kNm
P/A = 11.93 kN/sqm
Mx/Zx = -0.27 kN/sqm
My/Zy = 1.24 kN/sqm
Maximum Soil Pressure = 13.45 kN/sqm
Allowable Soil Pressure = 1x200 kN/sqm
= 200 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 126
Critical Load Combination = [26] : 0.68 (LOAD 3: DL1)
+0.68 (LOAD 4: DL2) -0.3
(LOAD 1: EX) -(LOAD 2:
EZ)
Pcomb = 39.15 kN
P = Pcomb + W1 x 0.68
P = 193.42 kN

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 61 of 91

Mx = 21.41 kNm
My = -64.27 kNm
P/A = 6.39 kN/sqm
Mx/Zx = 0.77 kN/sqm
My/Zy = -2.32 kN/sqm
Minimum Soil Pressure = 3.3 kN/sqm
> 0

Check For Buoyancy:


Depth of Water Table is below Depth of Foundation, hence Buoyancy check Not Applicable

Check For Sliding:


Critical Analysis Load Combination = 126
[26] : 0.68 (LOAD 3: DL1) +0.68 (LOAD 4:
Critical Load Combination =
DL2) -0.3 (LOAD 1: EX) -(LOAD 2: EZ)
Pcomb = 39.15 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 63.17 kN
shear Vy = 7.99 kN
Resultant sliding force = 63.67 kN
Downward force = Pcomb + (F1 + S1) x 0.68
= 193.42 kN
Upward water pressure = 0 kN
Net downward force = 193.42 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 77.37 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.22
> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 119
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) +
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 60.06 kN
Moment Mx = 39.16 kNm
P = Pcomb + (F1 + S1) x 0.68
= 214.33 kN
Stabilizing Moment for P = 589.41 kNm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 62 of 91

DeStabilizing Moment = 39.16 kNm


Overturning Factor of safety = 15.05
Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 126
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -0.3
Critical Load Combination =
(LOAD 1: EX) -(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 39.15 kN
Moment My = 64.27 kNm
P = Pcomb + (F1 + S1) x 0.68
= 193.42 kN
Stabilizing Moment for P = 531.91 kNm
DeStabilizing Moment = 64.27 kNm
Overturning Factor of safety = 8.28
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 405
Critical Load Combination = [126] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 150.8 kN
Mux = 35.98 kNm
Muy = -37.41 kNm
P/A = 4.99 kN/sqm
Mx/Zx = 1.3 kN/sqm
My/Zy = -1.35 kN/sqm

Deff = 252 mm
Beff = 5500 mm
SPu = 6.28 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 112.35 kNm
Ast Rqd = 3300 sqmm
Ast (min) = 3300 sqmm
Ast Prv (Distributed Across Total Width) = 20 - #16 @ 300
= 4021.2 sqmm

Top Steel Along L:


Ast Prv (Distributed Across Total Width) = 20 - #16 @ 300 c/c
= 4021.2 sqmm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 63 of 91

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 405
Critical Load Combination = [126] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 150.8 kN
Mux = 35.98 kNm
Muy = -37.41 kNm
P/A = 4.99 kN/sqm
Mx/Zx = 1.3 kN/sqm
My/Zy = -1.35 kN/sqm

Deff = 236 mm
Leff = 5500 mm
SPu = 6.33 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 113.27 kNm
Ast Rqd = 3300 sqmm
Ast (min) = 3300 sqmm
Ast Prv (Distributed Across Total
= 20 - #16 @ 300
Length)
= 4021.2 sqmm

Top Steel Along B:


Ast Prv (Distributed Across Total
= 20 - #16 @ 300 c/c
Length)
= 4021.2 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 252 mm
Critical Analysis Load Combination = 405
Critical Load Combination = [126] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 150.8 kN
Mux = 35.98 kNm
Muy = -37.41 kNm
P/A = 4.99 kN/sqm
Mx/Zx = 1.3 kN/sqm
My/Zy = -1.35 kN/sqm

Deff = 252 mm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 64 of 91

Beff = 5500 mm
SPu = 6.28 kN/sqm
Vu = SPu X (Loff - d) X B
= 79.41 kN
φVc = 922.16 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 236 mm
Critical Analysis Load Combination = 405
Critical Load Combination = [126] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) -(LOAD 1: EX) +0.5
(LOAD 7: RLL)
Pu = 150.8 kN
Mux = 35.98 kNm
Muy = -37.41 kNm
P/A = 4.99 kN/sqm
Mx/Zx = 1.3 kN/sqm
My/Zy = -1.35 kN/sqm

Deff = 236 mm
Leff = 5500 mm
SPu = 6.33 kN/sqm
Vu = SPu X (Boff - d) X L
= 80.62 kN
φVc = 866.28 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 122 mm

Critical Analysis Load Combination = 405


Critical Load Combination = [126] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 150.8 kN
Mux = 35.98 kNm
Muy = -37.41 kNm
P/A = 4.99 kN/sqm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 65 of 91

Mx/Zx = 1.3 kN/sqm


My/Zy = -1.35 kN/sqm

Deff = 244 mm
Leff = 644 mm
Beff = 644 mm
Punching Perimeter = 2576 mm
Punching Area = 628544 sqmm
SPu = Average Pressure
= 4.99 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 148.74 kN
φVn = 1247.23 kN
φVc = 823.17 kN
No Shear
Vu < φVc Reinforcement
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 405
Critical Load Combination = [126] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) -(LOAD 1: EX) +0.5
(LOAD 7: RLL)
Pu = 150.8 kN
A2 = 0.16 sqm
A1 = 2.56 sqm
Base Area = 30.25 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 4
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 4950.4 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 14


Footing No : FC11

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 66 of 91

Column No : C11 ( 300 mm X 400 mm)


Analysis No : 42

Concrete Grade : C28


Steel Grade : Fy415
Clear Cover : 40 mm
Dfd : 1.5 m
Dw : 10 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 0 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 0 %

Design cross section by Consider : Average pressure


overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 4400mm X 4300mm X 300mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 141.9 kN
Soil Weight, S1 = 0 kN
Total Weight, W1 = F1 + S1
= 141.9 kN
Offset Along L (Loff) = 2000 mm
Offset Along B (Boff) = 2000 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 313
Critical Load Combination = [55] : (LOAD 3: DL1) +(LOAD 4: DL2) +
(LOAD 5: LL1) +(LOAD 6: LL2) -0.71 (LOAD
2: EZ) +(LOAD 7: RLL)
Pcomb = 211.38 kN
P = Pcomb + W1
P = 353.28 kN
Mx = 7.31 kNm
My = -16.59 kNm
P/A = 18.67 kN/sqm
Mx/Zx = 0.53 kN/sqm
My/Zy = -1.22 kN/sqm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 67 of 91

Maximum Soil Pressure = 20.42 kN/sqm


Allowable Soil Pressure = 1x200 kN/sqm
= 200 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 123
Critical Load Combination = [23] : 0.68 (LOAD 3: DL1)
+0.68 (LOAD 4: DL2) +0.3
(LOAD 1: EX) +(LOAD 2:
EZ)
Pcomb = 9.91 kN
P = Pcomb + W1 x 0.68
P = 106.4 kN
Mx = -16.19 kNm
My = 26.76 kNm
P/A = 5.62 kN/sqm
Mx/Zx = -1.17 kN/sqm
My/Zy = 1.97 kN/sqm
Minimum Soil Pressure = 2.48 kN/sqm
> 0

Check For Buoyancy:


Depth of Water Table is below Depth of Foundation, hence Buoyancy check Not Applicable

Check For Sliding:


Critical Analysis Load Combination = 123
[23] : 0.68 (LOAD 3: DL1) +0.68 (LOAD 4:
Critical Load Combination =
DL2) +0.3 (LOAD 1: EX) +(LOAD 2: EZ)
Pcomb = 9.91 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 34.08 kN
shear Vy = 7.06 kN
Resultant sliding force = 34.8 kN
Downward force = Pcomb + (F1 + S1) x 0.68
= 106.4 kN
Upward water pressure = 0 kN
Net downward force = 106.4 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 42.56 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.22

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 68 of 91

> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 119
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) +
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 52.29 kN
Moment Mx = 31.94 kNm
P = Pcomb + (F1 + S1) x 0.68
= 148.78 kN
Stabilizing Moment for P = 327.31 kNm
DeStabilizing Moment = 31.94 kNm
Overturning Factor of safety = 10.25
Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 123
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2)
Critical Load Combination =
+0.3 (LOAD 1: EX) +(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 9.91 kN
Moment My = 26.76 kNm
P = Pcomb + (F1 + S1) x 0.68
= 106.4 kN
Stabilizing Moment for P = 228.75 kNm
DeStabilizing Moment = 26.76 kNm
Overturning Factor of safety = 8.55
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 2: EZ) +0.5 (LOAD 7: RLL)
Pu = 266.27 kN
Mux = 9.96 kNm
Muy = -23.46 kNm
P/A = 14.07 kN/sqm
Mx/Zx = 0.72 kN/sqm
My/Zy = -1.73 kN/sqm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 69 of 91

Deff = 252 mm
Beff = 4300 mm
SPu = 14.79 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 127.21 kNm
Ast Rqd = 2580 sqmm
Ast (min) = 2580 sqmm
Ast Prv (Distributed Across Total Width) = 16 - #16 @ 300
= 3216.96 sqmm

Top Steel Along L:


Ast Prv (Distributed Across Total Width) = 16 - #16 @ 300 c/c
= 3216.96 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 2: EZ) +0.5 (LOAD 7: RLL)
Pu = 266.27 kN
Mux = 9.96 kNm
Muy = -23.46 kNm
P/A = 14.07 kN/sqm
Mx/Zx = 0.72 kN/sqm
My/Zy = -1.73 kN/sqm

Deff = 236 mm
Leff = 4400 mm
SPu = 15.8 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 139.07 kNm
Ast Rqd = 2640 sqmm
Ast (min) = 2640 sqmm
Ast Prv (Distributed Across Total
= 16 - #16 @ 300
Length)
= 3216.96 sqmm

Top Steel Along B:


Ast Prv (Distributed Across Total
= 16 - #16 @ 300 c/c
Length)
= 3216.96 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 70 of 91

= 252 mm
Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 2: EZ) +0.5 (LOAD 7: RLL)
Pu = 266.27 kN
Mux = 9.96 kNm
Muy = -23.46 kNm
P/A = 14.07 kN/sqm
Mx/Zx = 0.72 kN/sqm
My/Zy = -1.73 kN/sqm

Deff = 252 mm
Beff = 4300 mm
SPu = 14.79 kN/sqm
Vu = SPu X (Loff - d) X B
= 111.18 kN
φVc = 720.96 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 236 mm
Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) -(LOAD 2: EZ) +0.5
(LOAD 7: RLL)
Pu = 266.27 kN
Mux = 9.96 kNm
Muy = -23.46 kNm
P/A = 14.07 kN/sqm
Mx/Zx = 0.72 kN/sqm
My/Zy = -1.73 kN/sqm

Deff = 236 mm
Leff = 4400 mm
SPu = 15.8 kN/sqm
Vu = SPu X (Boff - d) X L
= 122.66 kN
φVc = 693.02 kN
Vu < φVc

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 71 of 91

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 122 mm

Critical Analysis Load Combination = 406


Critical Load Combination = [127] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 2: EZ) +0.5 (LOAD 7: RLL)
Pu = 266.27 kN
Mux = 9.96 kNm
Muy = -23.46 kNm
P/A = 14.07 kN/sqm
Mx/Zx = 0.72 kN/sqm
My/Zy = -1.73 kN/sqm

Deff = 244 mm
Leff = 644 mm
Beff = 544 mm
Punching Perimeter = 2376 mm
Punching Area = 579744 sqmm
SPu = Average Pressure
= 14.07 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 261.34 kN
φVn = 1150.39 kN
φVc = 759.26 kN
No Shear
Vu < φVc Reinforcement
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) -(LOAD 2: EZ) +0.5
(LOAD 7: RLL)
Pu = 266.27 kN
A2 = 0.12 sqm
A1 = 2.4 sqm
Base Area = 18.92 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 72 of 91

SquareRoot(A1/A2) = 4.4721
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 3712.8 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 14


Footing No : FC12
Column No : C12 ( 400 mm X 400 mm)
Analysis No : 45

Concrete Grade : C28


Steel Grade : Fy415
Clear Cover : 40 mm
Dfd : 1.5 m
Dw : 10 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 0 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 0 %

Design cross section by Consider : Average pressure


overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 6450mm X 6450mm X 300mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 312.02 kN
Soil Weight, S1 = 0 kN
Total Weight, W1 = F1 + S1
= 312.02 kN
Offset Along L (Loff) = 3025 mm
Offset Along B (Boff) = 3025 mm

Check For Maximum Soil Pressure:

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 73 of 91

Critical Analysis Load Combination = 312


Critical Load Combination = [54] : (LOAD 3: DL1) +(LOAD 4: DL2) +
(LOAD 5: LL1) +(LOAD 6: LL2) +0.71 (LOAD
2: EZ) +(LOAD 7: RLL)
Pcomb = 190.53 kN
P = Pcomb + W1
P = 502.55 kN
Mx = -16 kNm
My = 27.78 kNm
P/A = 12.08 kN/sqm
Mx/Zx = -0.36 kN/sqm
My/Zy = 0.62 kN/sqm
Maximum Soil Pressure = 13.06 kN/sqm
Allowable Soil Pressure = 1x200 kN/sqm
= 200 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 126
Critical Load Combination = [26] : 0.68 (LOAD 3: DL1)
+0.68 (LOAD 4: DL2) -0.3
(LOAD 1: EX) -(LOAD 2:
EZ)
Pcomb = -52.23 kN
P = Pcomb + W1 x 0.68
P = 159.94 kN
Mx = 40.13 kNm
My = -43.62 kNm
P/A = 3.84 kN/sqm
Mx/Zx = 0.9 kN/sqm
My/Zy = -0.98 kN/sqm
Minimum Soil Pressure = 1.97 kN/sqm
> 0

Check For Buoyancy:


Depth of Water Table is below Depth of Foundation, hence Buoyancy check Not Applicable

Check For Sliding:


Critical Analysis Load Combination = 126
[26] : 0.68 (LOAD 3: DL1) +0.68 (LOAD 4:
Critical Load Combination =
DL2) -0.3 (LOAD 1: EX) -(LOAD 2: EZ)
Pcomb = -52.23 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 40.85 kN

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 74 of 91

shear Vy = 33.51 kN
Resultant sliding force = 52.84 kN
Downward force = Pcomb + (F1 + S1) x 0.68
= 159.94 kN
Upward water pressure = 0 kN
Net downward force = 159.94 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 63.98 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.21
> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 126
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -0.3
Critical Load Combination =
(LOAD 1: EX) -(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = -52.23 kN
Moment Mx = 40.13 kNm
P = Pcomb + (F1 + S1) x 0.68
= 159.94 kN
Stabilizing Moment for P = 515.8 kNm
DeStabilizing Moment = 40.13 kNm
Overturning Factor of safety = 12.85
Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 126
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -0.3
Critical Load Combination =
(LOAD 1: EX) -(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = -52.23 kN
Moment My = 43.62 kNm
P = Pcomb + (F1 + S1) x 0.68
= 159.94 kN
Stabilizing Moment for P = 515.8 kNm
DeStabilizing Moment = 43.62 kNm
Overturning Factor of safety = 11.83
Safe in Overturning > 1.50

Design For Bending:

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 75 of 91

Bottom Reinforcement Along L:


Critical Analysis Load Combination = 410
Critical Load Combination = [131] : 0.9 (LOAD 3: DL1) +0.9 (LOAD 4:
DL2) +(LOAD 2: EZ)
Pu = 213.27 kN
Mux = -22.56 kNm
Muy = 39.16 kNm
P/A = 5.13 kN/sqm
Mx/Zx = -0.5 kN/sqm
My/Zy = 0.88 kN/sqm

Deff = 252 mm
Beff = 6450 mm
SPu = 5.63 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 166.17 kNm
Ast Rqd = 3870 sqmm
Ast (min) = 3870 sqmm
Ast Prv (Distributed Across Total Width) = 23 - #16 @ 300
= 4624.38 sqmm

Top Steel Along L:


Deff = 252 mm
Beff = 6450 mm
S/W + Soil + Surcharge Load = 7.5 kN/sqm
Mu = 265.6 kNm
Pt = 0.24 %
Maximum of following
Ast Rqd (BM) = 3870 sqmm
Ast = Min Pt for Top Reinforcement X D X B
= 0.13% X 300 X 6450
= 2515.5 sqmm
Max Ast = 3870 sqmm
Ast Prv (Distributed Across Total Width) = 23 - #16 @ 300 c/c
= 4624.38 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 410
Critical Load Combination = [131] : 0.9 (LOAD 3: DL1) +0.9 (LOAD 4:
DL2) +(LOAD 2: EZ)
Pu = 213.27 kN
Mux = -22.56 kNm
Muy = 39.16 kNm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 76 of 91

P/A = 5.13 kN/sqm


Mx/Zx = -0.5 kN/sqm
My/Zy = 0.88 kN/sqm

Deff = 236 mm
Leff = 6450 mm
SPu = 6 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 177.12 kNm
Ast Rqd = 3870 sqmm
Ast (min) = 3870 sqmm
Ast Prv (Distributed Across Total
= 23 - #16 @ 300
Length)
= 4624.38 sqmm

Top Steel Along B:


Deff = 236 mm
Beff = 6450 mm
S/W + Soil + Surcharge Load = 7.5 kN/sqm
Mu = 265.6 kNm
Pt = 0.25 %
Maximum of following
Ast Rqd (BM) = 3870 sqmm
Ast = Min Pt for Top Reinforcement X D X L
= 0.13% X 300 X 6450
= 2515.5 sqmm
Max Ast = 3870 sqmm
Ast Prv (Distributed Across Total
= 23 - #16 @ 300 c/c
Length)
= 4624.38 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 252 mm
Critical Analysis Load Combination = 410
Critical Load Combination = [131] : 0.9 (LOAD 3: DL1) +0.9 (LOAD 4:
DL2) +(LOAD 2: EZ)
Pu = 213.27 kN
Mux = -22.56 kNm
Muy = 39.16 kNm
P/A = 5.13 kN/sqm
Mx/Zx = -0.5 kN/sqm
My/Zy = 0.88 kN/sqm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 77 of 91

Deff = 252 mm
Beff = 6450 mm
SPu = 5.63 kN/sqm
Vu = SPu X (Loff - d) X B
= 100.71 kN
φVc = 1081.44 kN
Vu < φVc
One Way Shear Along L (Tension Case):
At face of column
Soil + Surcharge Load,q = 7.5 kN/sqm
Deff = 252 mm
Beff = 6450 mm
Vu = q x Loff X B X 1.2
= 175.6 kN
φVc = 1081.44 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 236 mm
Critical Analysis Load Combination = 410
Critical Load Combination = [131] : 0.9 (LOAD 3: DL1)
+0.9 (LOAD 4: DL2) +
(LOAD 2: EZ)
Pu = 213.27 kN
Mux = -22.56 kNm
Muy = 39.16 kNm
P/A = 5.13 kN/sqm
Mx/Zx = -0.5 kN/sqm
My/Zy = 0.88 kN/sqm

Deff = 236 mm
Leff = 6450 mm
SPu = 6 kN/sqm
Vu = SPu X (Boff - d) X L
= 107.97 kN
φVc = 1015.91 kN
Vu < φVc

One Way Shear Along B (Tension Case):


At face of Column
Soil + Surcharge Load,q = 7.5 kN/sqm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 78 of 91

Deff = 236 mm
Leff = 6450 mm
Vu = q x Boff X L X 1.2
= 175.6 kN
φVc = 1015.91 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 122 mm

Critical Analysis Load Combination = 410


Critical Load Combination = [131] : 0.9 (LOAD 3: DL1) +0.9 (LOAD 4:
DL2) +(LOAD 2: EZ)
Pu = 213.27 kN
Mux = -22.56 kNm
Muy = 39.16 kNm
P/A = 5.13 kN/sqm
Mx/Zx = -0.5 kN/sqm
My/Zy = 0.88 kN/sqm

Deff = 244 mm
Leff = 644 mm
Beff = 644 mm
Punching Perimeter = 2576 mm
Punching Area = 628544 sqmm
SPu = Average Pressure
= 5.13 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 211.14 kN
φVn = 1247.23 kN
φVc = 823.17 kN
No Shear
Vu < φVc Reinforcement
Required

Design For Punching Shear (Tension Case):


At face of column
Pu = -18.24 kN
Deff = 244 mm
Leff = 400 mm
Beff = 400 mm
Punching Perimeter = 1600 mm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 79 of 91

Punching Area = 390400 sqmm


Vu = 18.24 kN
φVn = 774.68 kN
φVc = 511.29 kN
Vu < φVc

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 410
Critical Load Combination = [131] : 0.9 (LOAD 3: DL1)
+0.9 (LOAD 4: DL2) +
(LOAD 2: EZ)
Pu = 213.27 kN
A2 = 0.16 sqm
A1 = 2.56 sqm
Base Area = 41.6 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 4
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 4950.4 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 14


Footing No : FC13
Column No : C13 ( 300 mm X 300 mm)
Analysis No : 43

Concrete Grade : C28


Steel Grade : Fy415
Clear Cover : 40 mm
Dfd : 1.5 m
Dw : 10 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 0 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 80 of 91

Permissible area of loss of contact = 0 %

Design cross section by Consider : Average pressure


overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 1650mm X 1650mm X 300mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 20.42 kN
Soil Weight, S1 = 0 kN
Total Weight, W1 = F1 + S1
= 20.42 kN
Offset Along L (Loff) = 675 mm
Offset Along B (Boff) = 675 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 311
Critical Load Combination = [53] : (LOAD 3: DL1) +(LOAD 4: DL2) +
(LOAD 5: LL1) +(LOAD 6: LL2) -0.71 (LOAD
1: EX) +(LOAD 7: RLL)
Pcomb = 146.01 kN
P = Pcomb + W1
P = 166.43 kN
Mx = 19.75 kNm
My = 2.41 kNm
P/A = 61.13 kN/sqm
Mx/Zx = 26.38 kN/sqm
My/Zy = 3.22 kN/sqm
Maximum Soil Pressure = 90.73 kN/sqm
Allowable Soil Pressure = 1x200 kN/sqm
= 200 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 126
Critical Load Combination = [26] : 0.68 (LOAD 3: DL1)
+0.68 (LOAD 4: DL2) -0.3
(LOAD 1: EX) -(LOAD 2:
EZ)
Pcomb = 79.15 kN
P = Pcomb + W1 x 0.68
P = 93.03 kN
Mx = 18.01 kNm
My = -6.85 kNm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 81 of 91

P/A = 34.17 kN/sqm


Mx/Zx = 24.06 kN/sqm
My/Zy = -9.15 kN/sqm
Minimum Soil Pressure = 0.97 kN/sqm
> 0

Check For Buoyancy:


Depth of Water Table is below Depth of Foundation, hence Buoyancy check Not Applicable

Check For Sliding:


Critical Analysis Load Combination = 119
[19] : 0.68 (LOAD 3: DL1) +0.68 (LOAD 4:
Critical Load Combination =
DL2) +(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Pcomb = 106.73 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 1.51 kN
shear Vy = 36.06 kN
Resultant sliding force = 36.09 kN
Downward force = Pcomb + (F1 + S1) x 0.68
= 120.61 kN
Upward water pressure = 0 kN
Net downward force = 120.61 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 48.25 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.34
> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 119
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) +
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 106.73 kN
Moment Mx = 30.28 kNm
P = Pcomb + (F1 + S1) x 0.68
= 120.61 kN
Stabilizing Moment for P = 99.51 kNm
DeStabilizing Moment = 30.28 kNm
Overturning Factor of safety = 3.29

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 82 of 91

Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 125
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2)
Critical Load Combination =
+0.3 (LOAD 1: EX) -(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 79.69 kN
Moment My = 8.3 kNm
P = Pcomb + (F1 + S1) x 0.68
= 93.58 kN
Stabilizing Moment for P = 77.2 kNm
DeStabilizing Moment = 8.3 kNm
Overturning Factor of safety = 9.31
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 176.9 kN
Mux = -27.29 kNm
Muy = -1.58 kNm
P/A = 64.98 kN/sqm
Mx/Zx = -36.45 kN/sqm
My/Zy = -2.11 kN/sqm

Deff = 252 mm
Beff = 1650 mm
SPu = 101.43 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 38.13 kNm
Ast Rqd = 990 sqmm
Ast (min) = 990 sqmm
Ast Prv (Distributed Across Total Width) = 7 - #16 @ 300
= 1407.42 sqmm

Top Steel Along L:


Ast Prv (Distributed Across Total Width) = 7 - #16 @ 300 c/c
= 1407.42 sqmm

Bottom Reinforcement Along B:

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 83 of 91

Critical Analysis Load Combination = 401


Critical Load Combination = [122] : 1.4 (LOAD 3: DL1) +1.4 (LOAD 4:
DL2)
Pu = 205.32 kN
Mux = 0.28 kNm
Muy = 0.97 kNm
P/A = 75.42 kN/sqm
Mx/Zx = 0.38 kN/sqm
My/Zy = 1.3 kN/sqm

Deff = 236 mm
Leff = 1650 mm
SPu = 76.72 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 28.84 kNm
Ast Rqd = 990 sqmm
Ast (min) = 990 sqmm
Ast Prv (Distributed Across Total
= 7 - #16 @ 300
Length)
= 1407.42 sqmm

Top Steel Along B:


Ast Prv (Distributed Across Total
= 7 - #16 @ 300 c/c
Length)
= 1407.42 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 252 mm
Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 176.9 kN
Mux = -27.29 kNm
Muy = -1.58 kNm
P/A = 64.98 kN/sqm
Mx/Zx = -36.45 kN/sqm
My/Zy = -2.11 kN/sqm

Deff = 252 mm
Beff = 1650 mm
SPu = 101.43 kN/sqm
Vu = SPu X (Loff - d) X B

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 84 of 91

= 70.79 kN
φVc = 279.06 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 236 mm
Critical Analysis Load Combination = 401
Critical Load Combination = [122] : 1.4 (LOAD 3: DL1)
+1.4 (LOAD 4: DL2)
Pu = 205.32 kN
Mux = 0.28 kNm
Muy = 0.97 kNm
P/A = 75.42 kN/sqm
Mx/Zx = 0.38 kN/sqm
My/Zy = 1.3 kN/sqm

Deff = 236 mm
Leff = 1650 mm
SPu = 76.72 kN/sqm
Vu = SPu X (Boff - d) X L
= 55.57 kN
φVc = 260.83 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 122 mm

Critical Analysis Load Combination = 401


Critical Load Combination = [122] : 1.4 (LOAD 3: DL1) +1.4 (LOAD 4:
DL2)
Pu = 205.32 kN
Mux = 0.28 kNm
Muy = 0.97 kNm
P/A = 75.42 kN/sqm
Mx/Zx = 0.38 kN/sqm
My/Zy = 1.3 kN/sqm

Deff = 244 mm
Leff = 544 mm
Beff = 544 mm
Punching Perimeter = 2176 mm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 85 of 91

Punching Area = 530944 sqmm


SPu = Average Pressure
= 75.42 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 183 kN
φVn = 1053.56 kN
φVc = 695.35 kN
No Shear
Vu < φVc Reinforcement
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 401
Critical Load Combination = [122] : 1.4 (LOAD 3: DL1)
+1.4 (LOAD 4: DL2)
Pu = 205.32 kN
A2 = 0.09 sqm
A1 = 2.25 sqm
Base Area = 2.72 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 5
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 2784.6 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 14


Footing No : FC14
Column No : C14 ( 400 mm X 400 mm)
Analysis No : 44

Concrete Grade : C28


Steel Grade : Fy415
Clear Cover : 40 mm
Dfd : 1.5 m
Dw : 10 m

Density of Soil = 18 kN/cum

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 86 of 91

Soil Bearing Capacity = 200 kN/sqm


Permissible SBC Increase for EQ = 0 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 0 %

Design cross section by Consider : Average pressure


overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 3350mm X 3350mm X 300mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 84.17 kN
Soil Weight, S1 = 0 kN
Total Weight, W1 = F1 + S1
= 84.17 kN
Offset Along L (Loff) = 1475 mm
Offset Along B (Boff) = 1475 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 310
Critical Load Combination = [52] : (LOAD 3: DL1) +(LOAD 4: DL2) +
(LOAD 5: LL1) +(LOAD 6: LL2) +0.71 (LOAD
1: EX) +(LOAD 7: RLL)
Pcomb = 122.53 kN
P = Pcomb + W1
P = 206.7 kN
Mx = -36.05 kNm
My = -18.94 kNm
P/A = 18.42 kN/sqm
Mx/Zx = -5.75 kN/sqm
My/Zy = -3.02 kN/sqm
Maximum Soil Pressure = 27.19 kN/sqm
Allowable Soil Pressure = 1x200 kN/sqm
= 200 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 119
Critical Load Combination = [19] : 0.68 (LOAD 3: DL1)
+0.68 (LOAD 4: DL2) +
(LOAD 1: EX) +0.3 (LOAD
2: EZ)
Pcomb = 92.33 kN

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 87 of 91

P = Pcomb + W1 x 0.68
P = 149.57 kN
Mx = -56.52 kNm
My = -26.1 kNm
P/A = 13.33 kN/sqm
Mx/Zx = -9.02 kN/sqm
My/Zy = -4.17 kN/sqm
Minimum Soil Pressure = 0.14 kN/sqm
> 0

Check For Buoyancy:


Depth of Water Table is below Depth of Foundation, hence Buoyancy check Not Applicable

Check For Sliding:


Critical Analysis Load Combination = 119
[19] : 0.68 (LOAD 3: DL1) +0.68 (LOAD 4:
Critical Load Combination =
DL2) +(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Pcomb = 92.33 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 21.57 kN
shear Vy = 33.47 kN
Resultant sliding force = 39.82 kN
Downward force = Pcomb + (F1 + S1) x 0.68
= 149.57 kN
Upward water pressure = 0 kN
Net downward force = 149.57 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 59.83 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.5
> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 119
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) +
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 92.33 kN
Moment Mx = 56.52 kNm
P = Pcomb + (F1 + S1) x 0.68

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 88 of 91

= 149.57 kN
Stabilizing Moment for P = 250.53 kNm
DeStabilizing Moment = 56.52 kNm
Overturning Factor of safety = 4.43
Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 121
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 80.26 kN
Moment My = 28.1 kNm
P = Pcomb + (F1 + S1) x 0.68
= 137.49 kN
Stabilizing Moment for P = 230.3 kNm
DeStabilizing Moment = 28.1 kNm
Overturning Factor of safety = 8.2
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 147.93 kN
Mux = -50.86 kNm
Muy = -26.74 kNm
P/A = 13.18 kN/sqm
Mx/Zx = -8.12 kN/sqm
My/Zy = -4.27 kN/sqm

Deff = 252 mm
Beff = 3350 mm
SPu = 21.3 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 77.62 kNm
Ast Rqd = 2010 sqmm
Ast (min) = 2010 sqmm
Ast Prv (Distributed Across Total Width) = 13 - #16 @ 300
= 2613.78 sqmm

Top Steel Along L:

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 89 of 91

Ast Prv (Distributed Across Total Width) = 13 - #16 @ 300 c/c


= 2613.78 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 147.93 kN
Mux = -50.86 kNm
Muy = -26.74 kNm
P/A = 13.18 kN/sqm
Mx/Zx = -8.12 kN/sqm
My/Zy = -4.27 kN/sqm

Deff = 236 mm
Leff = 3350 mm
SPu = 17.45 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 63.59 kNm
Ast Rqd = 2010 sqmm
Ast (min) = 2010 sqmm
Ast Prv (Distributed Across Total
= 13 - #16 @ 300
Length)
= 2613.78 sqmm

Top Steel Along B:


Ast Prv (Distributed Across Total
= 13 - #16 @ 300 c/c
Length)
= 2613.78 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 252 mm
Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) +
(LOAD 1: EX) +0.5 (LOAD 7: RLL)
Pu = 147.93 kN
Mux = -50.86 kNm
Muy = -26.74 kNm
P/A = 13.18 kN/sqm
Mx/Zx = -8.12 kN/sqm
My/Zy = -4.27 kN/sqm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 90 of 91

Deff = 252 mm
Beff = 3350 mm
SPu = 21.3 kN/sqm
Vu = SPu X (Loff - d) X B
= 87.26 kN
φVc = 561.68 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 236 mm
Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) +(LOAD 1: EX) +0.5
(LOAD 7: RLL)
Pu = 147.93 kN
Mux = -50.86 kNm
Muy = -26.74 kNm
P/A = 13.18 kN/sqm
Mx/Zx = -8.12 kN/sqm
My/Zy = -4.27 kN/sqm

Deff = 236 mm
Leff = 3350 mm
SPu = 17.45 kN/sqm
Vu = SPu X (Boff - d) X L
= 72.42 kN
φVc = 527.64 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 122 mm

Critical Analysis Load Combination = 401


Critical Load Combination = [122] : 1.4 (LOAD 3: DL1) +1.4 (LOAD 4:
DL2)
Pu = 165.55 kN
Mux = 0.61 kNm
Muy = 0.42 kNm

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 91 of 91

P/A = 14.75 kN/sqm


Mx/Zx = 0.1 kN/sqm
My/Zy = 0.07 kN/sqm

Deff = 244 mm
Leff = 644 mm
Beff = 644 mm
Punching Perimeter = 2576 mm
Punching Area = 628544 sqmm
SPu = Average Pressure
= 14.75 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 159.43 kN
φVn = 1247.23 kN
φVc = 823.17 kN
No Shear
Vu < φVc Reinforcement
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 401
Critical Load Combination = [122] : 1.4 (LOAD 3: DL1)
+1.4 (LOAD 4: DL2)
Pu = 165.55 kN
A2 = 0.16 sqm
A1 = 2.56 sqm
Base Area = 11.22 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 4
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 4950.4 kN
Φ1Pnb > Pu, Hence Safe.