Footing - Design Calculation
Footing - Design Calculation
Definitions:
1. A = Plan area of footing base in 'sqmm'
2. Ast (min) = Area of longitudinal reinforcement as per code in 'sqmm'
3. Ast Prv = Area of tensile reinforcement provided in 'sqmm'
4. Ast Rqd = Area of longitudinal reinforcement from bearing moment
and minimum % steel provided by user and as per code
in 'sqmm'
5. Av = Area of shear reinforcement required in 'sqmm/m'
6. AvPrv = Area of shear reinforcement provided in 'sqmm/m'
7. A1 = Bearing area of footing at slope of 1:2 in 'sqmm'
8. A2 = C/s Area of column in 'sqmm'
9. B = Width of footing base in 'mm'
10. Beff = Effective width of footing in 'mm'
11. Boff = Footing offset along B in 'mm'
12. BoffB = Footing offset along B above column in plan in 'mm'
13. BoffT = Footing offset along B below column in planin 'mm'
14. B1 = Width of sloped footing at top in 'mm'
15. ColOff = Column offset in sloped footing in 'mm'
16. Cx = Width of column in 'mm'
17. Cy = Length of Column in 'mm'
18. D = Depth of footing in 'mm'
19. d = Effective Depth of footing in 'mm'
20. Dfd = Depth of founding layer in 'm'
21. Dw = Ground water level in 'm'
22. Ec = Modulus of elasticity of concrete in 'N/sqmm'
23. Es = Modulus of elasticity of steel in 'N/sqmm'
24. Foss = Safety factor against sliding
25. Fosu = Safety factor against uplift
26. Fst = Stress in steel in 'N/sqmm'
27. F'c = Characteristic strength of concrete in 'N/sqmm'
28. Icr = Moment of Inertia of concrete crack section in 'mm4'
29. L = Length of footing base in 'mm'
30. Leff = Effective length of footing in 'mm'
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 2 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 3 of 91
Code References:
ACI 318M - 14
Sr.No. Item Clause / Table
1. Ptmax : 7.3.3.1, 8.3.3.1, 9.3.3.1
2. Ptmin : 7.6.1.1 & 8.6.1.1/7.7.2.3
3. Vc : 22.6.5
4. Av : 22.5.10.5 & 22.6.7
5. Max Stirrup Spacing : 9.7.6.2 & 10.7.6.5
6. Vs : 22.5.1.2
7. fs,perm : 24.3.2.1
8. fc,perm : 22.2.2.4.1
9. Wcr : Eq 4.2(a)
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 4 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 5 of 91
My = 40.72 kNm
P/A = 6.91 kN/sqm
Mx/Zx = 1.44 kN/sqm
My/Zy = 3.55 kN/sqm
Minimum Soil Pressure = 1.93 kN/sqm
> 0
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 6 of 91
Along Length:
Critical Analysis Load Combination = 123
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2)
Critical Load Combination =
+0.3 (LOAD 1: EX) +(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 30.44 kN
Moment My = 40.72 kNm
P = Pcomb + (F1 + S1) x 0.68
= 116.17 kN
Stabilizing Moment for P = 238.14 kNm
DeStabilizing Moment = 40.72 kNm
Overturning Factor of safety = 5.85
Safe in Overturning > 1.50
Deff = 252 mm
Beff = 4100 mm
SPu = 12.83 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 90.05 kNm
Ast Rqd = 2460 sqmm
Ast (min) = 2460 sqmm
Ast Prv (Distributed Across Total Width) = 15 - #16 @ 300
= 3015.9 sqmm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 7 of 91
Deff = 236 mm
Leff = 4100 mm
SPu = 14.21 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 99.73 kNm
Ast Rqd = 2460 sqmm
Ast (min) = 2460 sqmm
Ast Prv (Distributed Across Total
= 15 - #16 @ 300
Length)
= 3015.9 sqmm
Deff = 252 mm
Beff = 4100 mm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 8 of 91
= 236 mm
Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) -(LOAD 2: EZ) +0.5
(LOAD 7: RLL)
Pu = 184.13 kN
Mux = -21.61 kNm
Muy = -37.45 kNm
P/A = 10.95 kN/sqm
Mx/Zx = -1.88 kN/sqm
My/Zy = -3.26 kN/sqm
Deff = 236 mm
Leff = 4100 mm
SPu = 14.21 kN/sqm
Vu = SPu X (Boff - d) X L
= 94.06 kN
φVc = 645.77 kN
Vu < φVc
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 9 of 91
Deff = 244 mm
Leff = 644 mm
Beff = 644 mm
Punching Perimeter = 2576 mm
Punching Area = 628544 sqmm
SPu = Average Pressure
= 11.1 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 182.07 kN
φVn = 1247.23 kN
φVc = 823.17 kN
No Shear
Vu < φVc Reinforcement
Required
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 10 of 91
Analysis No : 33
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 11 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 12 of 91
Along Length:
Critical Analysis Load Combination = 124
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -0.3
Critical Load Combination =
(LOAD 1: EX) +(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 59.61 kN
Moment My = 20.62 kNm
P = Pcomb + (F1 + S1) x 0.68
= 98.18 kN
Stabilizing Moment for P = 135 kNm
DeStabilizing Moment = 20.62 kNm
Overturning Factor of safety = 6.55
Safe in Overturning > 1.50
Deff = 252 mm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 13 of 91
Beff = 2750 mm
SPu = 37.69 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 71.54 kNm
Ast Rqd = 1650 sqmm
Ast (min) = 1650 sqmm
Ast Prv (Distributed Across Total Width) = 11 - #16 @ 300
= 2211.66 sqmm
Deff = 236 mm
Leff = 2750 mm
SPu = 38.16 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 72.43 kNm
Ast Rqd = 1650 sqmm
Ast (min) = 1650 sqmm
Ast Prv (Distributed Across Total
= 11 - #16 @ 300
Length)
= 2211.66 sqmm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 14 of 91
Deff = 252 mm
Beff = 2750 mm
SPu = 37.69 kN/sqm
Vu = SPu X (Loff - d) X B
= 95.66 kN
φVc = 461.08 kN
Vu < φVc
= 236 mm
Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) -(LOAD 2: EZ) +0.5
(LOAD 7: RLL)
Pu = 243.31 kN
Mux = -19.11 kNm
Muy = -20.74 kNm
P/A = 32.17 kN/sqm
Mx/Zx = -5.51 kN/sqm
My/Zy = -5.98 kN/sqm
Deff = 236 mm
Leff = 2750 mm
SPu = 38.16 kN/sqm
Vu = SPu X (Boff - d) X L
= 98.53 kN
φVc = 433.14 kN
Vu < φVc
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 15 of 91
Deff = 244 mm
Leff = 644 mm
Beff = 644 mm
Punching Perimeter = 2576 mm
Punching Area = 628544 sqmm
SPu = Average Pressure
= 32.17 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 229.97 kN
φVn = 1247.23 kN
φVc = 823.17 kN
No Shear
Vu < φVc Reinforcement
Required
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 16 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 17 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 18 of 91
Along Length:
Critical Analysis Load Combination = 121
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 21.98 kN
Moment My = 28.22 kNm
P = Pcomb + (F1 + S1) x 0.68
= 80.94 kN
Stabilizing Moment for P = 137.6 kNm
DeStabilizing Moment = 28.22 kNm
Overturning Factor of safety = 4.88
Safe in Overturning > 1.50
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 19 of 91
Deff = 252 mm
Beff = 3400 mm
SPu = 17.19 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 65.77 kNm
Ast Rqd = 2040 sqmm
Ast (min) = 2040 sqmm
Ast Prv (Distributed Across Total Width) = 13 - #16 @ 300
= 2613.78 sqmm
Deff = 236 mm
Leff = 3400 mm
SPu = 19.83 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 75.85 kNm
Ast Rqd = 2040 sqmm
Ast (min) = 2040 sqmm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 20 of 91
Deff = 252 mm
Beff = 3400 mm
SPu = 17.19 kN/sqm
Vu = SPu X (Loff - d) X B
= 72.96 kN
φVc = 570.06 kN
Vu < φVc
= 236 mm
Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) +(LOAD 1: EX) +0.5
(LOAD 7: RLL)
Pu = 179.27 kN
Mux = -11.05 kNm
Muy = -28.32 kNm
P/A = 15.51 kN/sqm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 21 of 91
Deff = 236 mm
Leff = 3400 mm
SPu = 19.83 kN/sqm
Vu = SPu X (Boff - d) X L
= 85.23 kN
φVc = 535.52 kN
Vu < φVc
Deff = 244 mm
Leff = 644 mm
Beff = 644 mm
Punching Perimeter = 2576 mm
Punching Area = 628544 sqmm
SPu = Average Pressure
= 15.51 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 172.84 kN
φVn = 1247.23 kN
φVc = 823.17 kN
No Shear
Vu < φVc Reinforcement
Required
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 22 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 23 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 24 of 91
Depth of Water Table is below Depth of Foundation, hence Buoyancy check Not Applicable
Along Length:
Critical Analysis Load Combination = 123
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2)
Critical Load Combination =
+0.3 (LOAD 1: EX) +(LOAD 2: EZ)
Factor of safety = 1.50
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 25 of 91
Pcomb = -8.63 kN
Moment My = 65.64 kNm
P = Pcomb + (F1 + S1) x 0.68
= 200.26 kN
Stabilizing Moment for P = 640.84 kNm
DeStabilizing Moment = 65.64 kNm
Overturning Factor of safety = 9.76
Safe in Overturning > 1.50
Deff = 252 mm
Beff = 6400 mm
SPu = 4.73 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 136.35 kNm
Ast Rqd = 3840 sqmm
Ast (min) = 3840 sqmm
Ast Prv (Distributed Across Total Width) = 23 - #16 @ 300
= 4624.38 sqmm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 26 of 91
Deff = 236 mm
Leff = 6400 mm
SPu = 5.07 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 146.05 kNm
Ast Rqd = 3840 sqmm
Ast (min) = 3840 sqmm
Ast Prv (Distributed Across Total
= 23 - #16 @ 300
Length)
= 4624.38 sqmm
Deff = 252 mm
Beff = 6400 mm
SPu = 4.73 kN/sqm
Vu = SPu X (Loff - d) X B
= 83.26 kN
φVc = 1073.06 kN
Vu < φVc
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 27 of 91
= 236 mm
Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) -(LOAD 2: EZ) +0.5
(LOAD 7: RLL)
Pu = 161.1 kN
Mux = -4.18 kNm
Muy = -49.72 kNm
P/A = 3.93 kN/sqm
Mx/Zx = -0.1 kN/sqm
My/Zy = -1.14 kN/sqm
Deff = 236 mm
Leff = 6400 mm
SPu = 5.07 kN/sqm
Vu = SPu X (Boff - d) X L
= 89.71 kN
φVc = 1008.03 kN
Vu < φVc
Deff = 244 mm
Leff = 644 mm
Beff = 644 mm
Punching Perimeter = 2576 mm
Punching Area = 628544 sqmm
SPu = Average Pressure
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 28 of 91
= 4.1 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 166.41 kN
φVn = 1247.23 kN
φVc = 823.17 kN
No Shear
Vu < φVc Reinforcement
Required
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 29 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 30 of 91
Pcomb = 75.74 kN
P = Pcomb + W1 x 0.68
P = 96.12 kN
Mx = 5.53 kNm
My = -25.36 kNm
P/A = 24.05 kN/sqm
Mx/Zx = 4.05 kN/sqm
My/Zy = -19.52 kN/sqm
Minimum Soil Pressure = 0.48 kN/sqm
> 0
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 31 of 91
Along Length:
Critical Analysis Load Combination = 126
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -0.3
Critical Load Combination =
(LOAD 1: EX) -(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 75.74 kN
Moment My = 25.36 kNm
P = Pcomb + (F1 + S1) x 0.68
= 96.12 kN
Stabilizing Moment for P = 93.72 kNm
DeStabilizing Moment = 25.36 kNm
Overturning Factor of safety = 3.7
Safe in Overturning > 1.50
Deff = 252 mm
Beff = 1950 mm
SPu = 71.85 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 47.68 kNm
Ast Rqd = 1170 sqmm
Ast (min) = 1170 sqmm
Ast Prv (Distributed Across Total Width) = 8 - #16 @ 300
= 1608.48 sqmm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 32 of 91
Deff = 236 mm
Leff = 2050 mm
SPu = 63.76 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 44.48 kNm
Ast Rqd = 1230 sqmm
Ast (min) = 1230 sqmm
Ast Prv (Distributed Across Total
= 8 - #16 @ 300
Length)
= 1608.48 sqmm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 33 of 91
Deff = 252 mm
Beff = 1950 mm
SPu = 71.85 kN/sqm
Vu = SPu X (Loff - d) X B
= 80.28 kN
φVc = 326.95 kN
Vu < φVc
= 236 mm
Critical Analysis Load Combination = 410
Critical Load Combination = [131] : 0.9 (LOAD 3: DL1)
+0.9 (LOAD 4: DL2) +
(LOAD 2: EZ)
Pu = 184.81 kN
Mux = 3.33 kNm
Muy = 22.77 kNm
P/A = 46.23 kN/sqm
Mx/Zx = 2.44 kN/sqm
My/Zy = 17.52 kN/sqm
Deff = 236 mm
Leff = 2050 mm
SPu = 63.76 kN/sqm
Vu = SPu X (Boff - d) X L
= 76.98 kN
φVc = 322.89 kN
Vu < φVc
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 34 of 91
Deff = 244 mm
Leff = 644 mm
Beff = 544 mm
Punching Perimeter = 2376 mm
Punching Area = 579744 sqmm
SPu = Average Pressure
= 58.93 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 214.94 kN
φVn = 1150.39 kN
φVc = 759.26 kN
No Shear
Vu < φVc Reinforcement
Required
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 35 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 36 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 37 of 91
Along Length:
Critical Analysis Load Combination = 125
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2)
Critical Load Combination =
+0.3 (LOAD 1: EX) -(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 79.16 kN
Moment My = 11.27 kNm
P = Pcomb + (F1 + S1) x 0.68
= 88.46 kN
Stabilizing Moment for P = 59.71 kNm
DeStabilizing Moment = 11.27 kNm
Overturning Factor of safety = 5.3
Safe in Overturning > 1.50
Deff = 252 mm
Beff = 1350 mm
SPu = 138.94 kN/sqm
Mu = SPu X B X Loff X Loff / 2
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 38 of 91
= 25.85 kNm
Ast Rqd = 810 sqmm
Ast (min) = 810 sqmm
Ast Prv (Distributed Across Total Width) = 6 - #16 @ 300
= 1206.36 sqmm
Deff = 236 mm
Leff = 1350 mm
SPu = 115.84 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 21.55 kNm
Ast Rqd = 810 sqmm
Ast (min) = 810 sqmm
Ast Prv (Distributed Across Total
= 6 - #16 @ 300
Length)
= 1206.36 sqmm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 39 of 91
Pu = 186.68 kN
Mux = 14.97 kNm
Muy = 3.99 kNm
P/A = 102.43 kN/sqm
Mx/Zx = 36.51 kN/sqm
My/Zy = 9.73 kN/sqm
Deff = 252 mm
Beff = 1350 mm
SPu = 138.94 kN/sqm
Vu = SPu X (Loff - d) X B
= 51.21 kN
φVc = 235.09 kN
Vu < φVc
= 236 mm
Critical Analysis Load Combination = 401
Critical Load Combination = [122] : 1.4 (LOAD 3: DL1)
+1.4 (LOAD 4: DL2)
Pu = 209.55 kN
Mux = 0.44 kNm
Muy = 0.35 kNm
P/A = 114.98 kN/sqm
Mx/Zx = 1.07 kN/sqm
My/Zy = 0.86 kN/sqm
Deff = 236 mm
Leff = 1350 mm
SPu = 115.84 kN/sqm
Vu = SPu X (Boff - d) X L
= 45.2 kN
φVc = 219.17 kN
Vu < φVc
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 40 of 91
Pu = 209.55 kN
Mux = 0.44 kNm
Muy = 0.35 kNm
P/A = 114.98 kN/sqm
Mx/Zx = 1.07 kN/sqm
My/Zy = 0.86 kN/sqm
Deff = 244 mm
Leff = 544 mm
Beff = 544 mm
Punching Perimeter = 2176 mm
Punching Area = 530944 sqmm
SPu = Average Pressure
= 114.98 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 175.53 kN
φVn = 1053.56 kN
φVc = 695.35 kN
No Shear
Vu < φVc Reinforcement
Required
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 41 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 42 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 43 of 91
Force
= 1.32
> 1.2
Along Length:
Critical Analysis Load Combination = 121
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 57.16 kN
Moment My = 18.87 kNm
P = Pcomb + (F1 + S1) x 0.68
= 92.96 kN
Stabilizing Moment for P = 120.85 kNm
DeStabilizing Moment = 18.87 kNm
Overturning Factor of safety = 6.41
Safe in Overturning > 1.50
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 44 of 91
Deff = 252 mm
Beff = 2600 mm
SPu = 28.9 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 49.69 kNm
Ast Rqd = 1560 sqmm
Ast (min) = 1560 sqmm
Ast Prv (Distributed Across Total Width) = 10 - #16 @ 300
= 2010.6 sqmm
Deff = 236 mm
Leff = 2700 mm
SPu = 28.11 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 50.19 kNm
Ast Rqd = 1620 sqmm
Ast (min) = 1620 sqmm
Ast Prv (Distributed Across Total
= 10 - #16 @ 300
Length)
= 2010.6 sqmm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 45 of 91
Deff = 252 mm
Beff = 2600 mm
SPu = 28.9 kN/sqm
Vu = SPu X (Loff - d) X B
= 67.48 kN
φVc = 435.93 kN
Vu < φVc
= 236 mm
Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) +(LOAD 1: EX) +0.5
(LOAD 7: RLL)
Pu = 155.52 kN
Mux = -21.32 kNm
Muy = -18.13 kNm
P/A = 22.15 kN/sqm
Mx/Zx = -6.75 kN/sqm
My/Zy = -5.96 kN/sqm
Deff = 236 mm
Leff = 2700 mm
SPu = 28.11 kN/sqm
Vu = SPu X (Boff - d) X L
= 69.38 kN
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 46 of 91
φVc = 425.26 kN
Vu < φVc
Deff = 244 mm
Leff = 644 mm
Beff = 544 mm
Punching Perimeter = 2376 mm
Punching Area = 579744 sqmm
SPu = Average Pressure
= 22.63 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 150.91 kN
φVn = 1150.39 kN
φVc = 759.26 kN
No Shear
Vu < φVc Reinforcement
Required
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 47 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 48 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 49 of 91
Along Length:
Critical Analysis Load Combination = 124
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -0.3
Critical Load Combination =
(LOAD 1: EX) +(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 101.52 kN
Moment My = 10.84 kNm
P = Pcomb + (F1 + S1) x 0.68
= 111.52 kN
Stabilizing Moment for P = 78.06 kNm
DeStabilizing Moment = 10.84 kNm
Overturning Factor of safety = 7.2
Safe in Overturning > 1.50
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 50 of 91
Deff = 252 mm
Beff = 1400 mm
SPu = 143.58 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 30.4 kNm
Ast Rqd = 840 sqmm
Ast (min) = 840 sqmm
Ast Prv (Distributed Across Total Width) = 6 - #16 @ 300
= 1206.36 sqmm
Deff = 236 mm
Leff = 1400 mm
SPu = 120.66 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 25.55 kNm
Ast Rqd = 840 sqmm
Ast (min) = 840 sqmm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 51 of 91
Deff = 252 mm
Beff = 1400 mm
SPu = 143.58 kN/sqm
Vu = SPu X (Loff - d) X B
= 59.9 kN
φVc = 242.13 kN
Vu < φVc
= 236 mm
Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) -(LOAD 2: EZ) +0.5
(LOAD 7: RLL)
Pu = 191.61 kN
Mux = 3.7 kNm
Muy = -10.48 kNm
P/A = 97.76 kN/sqm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 52 of 91
Deff = 236 mm
Leff = 1400 mm
SPu = 120.66 kN/sqm
Vu = SPu X (Boff - d) X L
= 53.04 kN
φVc = 225.9 kN
Vu < φVc
Deff = 244 mm
Leff = 544 mm
Beff = 544 mm
Punching Perimeter = 2176 mm
Punching Area = 530944 sqmm
SPu = Average Pressure
= 110.09 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 183.2 kN
φVn = 1053.56 kN
φVc = 695.35 kN
No Shear
Vu < φVc Reinforcement
Required
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 53 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 54 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 55 of 91
Along Length:
Critical Analysis Load Combination = 121
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 60.23 kN
Moment My = 18.5 kNm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 56 of 91
Deff = 252 mm
Beff = 2700 mm
SPu = 31.17 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 60.6 kNm
Ast Rqd = 1620 sqmm
Ast (min) = 1620 sqmm
Ast Prv (Distributed Across Total Width) = 10 - #16 @ 300
= 2010.6 sqmm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 57 of 91
Deff = 236 mm
Leff = 2800 mm
SPu = 28.55 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 57.56 kNm
Ast Rqd = 1680 sqmm
Ast (min) = 1680 sqmm
Ast Prv (Distributed Across Total
= 11 - #16 @ 300
Length)
= 2211.66 sqmm
Deff = 252 mm
Beff = 2700 mm
SPu = 31.17 kN/sqm
Vu = SPu X (Loff - d) X B
= 79.79 kN
φVc = 452.7 kN
Vu < φVc
= 236 mm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 58 of 91
Deff = 236 mm
Leff = 2800 mm
SPu = 28.55 kN/sqm
Vu = SPu X (Boff - d) X L
= 77.06 kN
φVc = 441.01 kN
Vu < φVc
Deff = 244 mm
Leff = 644 mm
Beff = 544 mm
Punching Perimeter = 2376 mm
Punching Area = 579744 sqmm
SPu = Average Pressure
= 23.16 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 59 of 91
= 167 kN
φVn = 1150.39 kN
φVc = 759.26 kN
No Shear
Vu < φVc Reinforcement
Required
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 60 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 61 of 91
Mx = 21.41 kNm
My = -64.27 kNm
P/A = 6.39 kN/sqm
Mx/Zx = 0.77 kN/sqm
My/Zy = -2.32 kN/sqm
Minimum Soil Pressure = 3.3 kN/sqm
> 0
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 62 of 91
Along Length:
Critical Analysis Load Combination = 126
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -0.3
Critical Load Combination =
(LOAD 1: EX) -(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 39.15 kN
Moment My = 64.27 kNm
P = Pcomb + (F1 + S1) x 0.68
= 193.42 kN
Stabilizing Moment for P = 531.91 kNm
DeStabilizing Moment = 64.27 kNm
Overturning Factor of safety = 8.28
Safe in Overturning > 1.50
Deff = 252 mm
Beff = 5500 mm
SPu = 6.28 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 112.35 kNm
Ast Rqd = 3300 sqmm
Ast (min) = 3300 sqmm
Ast Prv (Distributed Across Total Width) = 20 - #16 @ 300
= 4021.2 sqmm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 63 of 91
Deff = 236 mm
Leff = 5500 mm
SPu = 6.33 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 113.27 kNm
Ast Rqd = 3300 sqmm
Ast (min) = 3300 sqmm
Ast Prv (Distributed Across Total
= 20 - #16 @ 300
Length)
= 4021.2 sqmm
Deff = 252 mm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 64 of 91
Beff = 5500 mm
SPu = 6.28 kN/sqm
Vu = SPu X (Loff - d) X B
= 79.41 kN
φVc = 922.16 kN
Vu < φVc
= 236 mm
Critical Analysis Load Combination = 405
Critical Load Combination = [126] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) -(LOAD 1: EX) +0.5
(LOAD 7: RLL)
Pu = 150.8 kN
Mux = 35.98 kNm
Muy = -37.41 kNm
P/A = 4.99 kN/sqm
Mx/Zx = 1.3 kN/sqm
My/Zy = -1.35 kN/sqm
Deff = 236 mm
Leff = 5500 mm
SPu = 6.33 kN/sqm
Vu = SPu X (Boff - d) X L
= 80.62 kN
φVc = 866.28 kN
Vu < φVc
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 65 of 91
Deff = 244 mm
Leff = 644 mm
Beff = 644 mm
Punching Perimeter = 2576 mm
Punching Area = 628544 sqmm
SPu = Average Pressure
= 4.99 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 148.74 kN
φVn = 1247.23 kN
φVc = 823.17 kN
No Shear
Vu < φVc Reinforcement
Required
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 66 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 67 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 68 of 91
> 1.2
Along Length:
Critical Analysis Load Combination = 123
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2)
Critical Load Combination =
+0.3 (LOAD 1: EX) +(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 9.91 kN
Moment My = 26.76 kNm
P = Pcomb + (F1 + S1) x 0.68
= 106.4 kN
Stabilizing Moment for P = 228.75 kNm
DeStabilizing Moment = 26.76 kNm
Overturning Factor of safety = 8.55
Safe in Overturning > 1.50
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 69 of 91
Deff = 252 mm
Beff = 4300 mm
SPu = 14.79 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 127.21 kNm
Ast Rqd = 2580 sqmm
Ast (min) = 2580 sqmm
Ast Prv (Distributed Across Total Width) = 16 - #16 @ 300
= 3216.96 sqmm
Deff = 236 mm
Leff = 4400 mm
SPu = 15.8 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 139.07 kNm
Ast Rqd = 2640 sqmm
Ast (min) = 2640 sqmm
Ast Prv (Distributed Across Total
= 16 - #16 @ 300
Length)
= 3216.96 sqmm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 70 of 91
= 252 mm
Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1) +1.2 (LOAD 4:
DL2) +0.5 (LOAD 5: LL1) +(LOAD 6: LL2) -
(LOAD 2: EZ) +0.5 (LOAD 7: RLL)
Pu = 266.27 kN
Mux = 9.96 kNm
Muy = -23.46 kNm
P/A = 14.07 kN/sqm
Mx/Zx = 0.72 kN/sqm
My/Zy = -1.73 kN/sqm
Deff = 252 mm
Beff = 4300 mm
SPu = 14.79 kN/sqm
Vu = SPu X (Loff - d) X B
= 111.18 kN
φVc = 720.96 kN
Vu < φVc
= 236 mm
Critical Analysis Load Combination = 406
Critical Load Combination = [127] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) -(LOAD 2: EZ) +0.5
(LOAD 7: RLL)
Pu = 266.27 kN
Mux = 9.96 kNm
Muy = -23.46 kNm
P/A = 14.07 kN/sqm
Mx/Zx = 0.72 kN/sqm
My/Zy = -1.73 kN/sqm
Deff = 236 mm
Leff = 4400 mm
SPu = 15.8 kN/sqm
Vu = SPu X (Boff - d) X L
= 122.66 kN
φVc = 693.02 kN
Vu < φVc
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 71 of 91
Deff = 244 mm
Leff = 644 mm
Beff = 544 mm
Punching Perimeter = 2376 mm
Punching Area = 579744 sqmm
SPu = Average Pressure
= 14.07 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 261.34 kN
φVn = 1150.39 kN
φVc = 759.26 kN
No Shear
Vu < φVc Reinforcement
Required
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 72 of 91
SquareRoot(A1/A2) = 4.4721
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 3712.8 kN
Φ1Pnb > Pu, Hence Safe.
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 73 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 74 of 91
shear Vy = 33.51 kN
Resultant sliding force = 52.84 kN
Downward force = Pcomb + (F1 + S1) x 0.68
= 159.94 kN
Upward water pressure = 0 kN
Net downward force = 159.94 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 63.98 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.21
> 1.2
Along Length:
Critical Analysis Load Combination = 126
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -0.3
Critical Load Combination =
(LOAD 1: EX) -(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = -52.23 kN
Moment My = 43.62 kNm
P = Pcomb + (F1 + S1) x 0.68
= 159.94 kN
Stabilizing Moment for P = 515.8 kNm
DeStabilizing Moment = 43.62 kNm
Overturning Factor of safety = 11.83
Safe in Overturning > 1.50
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 75 of 91
Deff = 252 mm
Beff = 6450 mm
SPu = 5.63 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 166.17 kNm
Ast Rqd = 3870 sqmm
Ast (min) = 3870 sqmm
Ast Prv (Distributed Across Total Width) = 23 - #16 @ 300
= 4624.38 sqmm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 76 of 91
Deff = 236 mm
Leff = 6450 mm
SPu = 6 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 177.12 kNm
Ast Rqd = 3870 sqmm
Ast (min) = 3870 sqmm
Ast Prv (Distributed Across Total
= 23 - #16 @ 300
Length)
= 4624.38 sqmm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 77 of 91
Deff = 252 mm
Beff = 6450 mm
SPu = 5.63 kN/sqm
Vu = SPu X (Loff - d) X B
= 100.71 kN
φVc = 1081.44 kN
Vu < φVc
One Way Shear Along L (Tension Case):
At face of column
Soil + Surcharge Load,q = 7.5 kN/sqm
Deff = 252 mm
Beff = 6450 mm
Vu = q x Loff X B X 1.2
= 175.6 kN
φVc = 1081.44 kN
Vu < φVc
= 236 mm
Critical Analysis Load Combination = 410
Critical Load Combination = [131] : 0.9 (LOAD 3: DL1)
+0.9 (LOAD 4: DL2) +
(LOAD 2: EZ)
Pu = 213.27 kN
Mux = -22.56 kNm
Muy = 39.16 kNm
P/A = 5.13 kN/sqm
Mx/Zx = -0.5 kN/sqm
My/Zy = 0.88 kN/sqm
Deff = 236 mm
Leff = 6450 mm
SPu = 6 kN/sqm
Vu = SPu X (Boff - d) X L
= 107.97 kN
φVc = 1015.91 kN
Vu < φVc
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 78 of 91
Deff = 236 mm
Leff = 6450 mm
Vu = q x Boff X L X 1.2
= 175.6 kN
φVc = 1015.91 kN
Vu < φVc
Deff = 244 mm
Leff = 644 mm
Beff = 644 mm
Punching Perimeter = 2576 mm
Punching Area = 628544 sqmm
SPu = Average Pressure
= 5.13 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 211.14 kN
φVn = 1247.23 kN
φVc = 823.17 kN
No Shear
Vu < φVc Reinforcement
Required
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 79 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 80 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 81 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 82 of 91
Along Length:
Critical Analysis Load Combination = 125
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2)
Critical Load Combination =
+0.3 (LOAD 1: EX) -(LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 79.69 kN
Moment My = 8.3 kNm
P = Pcomb + (F1 + S1) x 0.68
= 93.58 kN
Stabilizing Moment for P = 77.2 kNm
DeStabilizing Moment = 8.3 kNm
Overturning Factor of safety = 9.31
Safe in Overturning > 1.50
Deff = 252 mm
Beff = 1650 mm
SPu = 101.43 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 38.13 kNm
Ast Rqd = 990 sqmm
Ast (min) = 990 sqmm
Ast Prv (Distributed Across Total Width) = 7 - #16 @ 300
= 1407.42 sqmm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 83 of 91
Deff = 236 mm
Leff = 1650 mm
SPu = 76.72 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 28.84 kNm
Ast Rqd = 990 sqmm
Ast (min) = 990 sqmm
Ast Prv (Distributed Across Total
= 7 - #16 @ 300
Length)
= 1407.42 sqmm
Deff = 252 mm
Beff = 1650 mm
SPu = 101.43 kN/sqm
Vu = SPu X (Loff - d) X B
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 84 of 91
= 70.79 kN
φVc = 279.06 kN
Vu < φVc
= 236 mm
Critical Analysis Load Combination = 401
Critical Load Combination = [122] : 1.4 (LOAD 3: DL1)
+1.4 (LOAD 4: DL2)
Pu = 205.32 kN
Mux = 0.28 kNm
Muy = 0.97 kNm
P/A = 75.42 kN/sqm
Mx/Zx = 0.38 kN/sqm
My/Zy = 1.3 kN/sqm
Deff = 236 mm
Leff = 1650 mm
SPu = 76.72 kN/sqm
Vu = SPu X (Boff - d) X L
= 55.57 kN
φVc = 260.83 kN
Vu < φVc
Deff = 244 mm
Leff = 544 mm
Beff = 544 mm
Punching Perimeter = 2176 mm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 85 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 86 of 91
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 87 of 91
P = Pcomb + W1 x 0.68
P = 149.57 kN
Mx = -56.52 kNm
My = -26.1 kNm
P/A = 13.33 kN/sqm
Mx/Zx = -9.02 kN/sqm
My/Zy = -4.17 kN/sqm
Minimum Soil Pressure = 0.14 kN/sqm
> 0
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 88 of 91
= 149.57 kN
Stabilizing Moment for P = 250.53 kNm
DeStabilizing Moment = 56.52 kNm
Overturning Factor of safety = 4.43
Safe in Overturning > 1.50
Along Length:
Critical Analysis Load Combination = 121
0.68 (LOAD 3: DL1) +0.68 (LOAD 4: DL2) -
Critical Load Combination =
(LOAD 1: EX) +0.3 (LOAD 2: EZ)
Factor of safety = 1.50
Pcomb = 80.26 kN
Moment My = 28.1 kNm
P = Pcomb + (F1 + S1) x 0.68
= 137.49 kN
Stabilizing Moment for P = 230.3 kNm
DeStabilizing Moment = 28.1 kNm
Overturning Factor of safety = 8.2
Safe in Overturning > 1.50
Deff = 252 mm
Beff = 3350 mm
SPu = 21.3 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 77.62 kNm
Ast Rqd = 2010 sqmm
Ast (min) = 2010 sqmm
Ast Prv (Distributed Across Total Width) = 13 - #16 @ 300
= 2613.78 sqmm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 89 of 91
Deff = 236 mm
Leff = 3350 mm
SPu = 17.45 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 63.59 kNm
Ast Rqd = 2010 sqmm
Ast (min) = 2010 sqmm
Ast Prv (Distributed Across Total
= 13 - #16 @ 300
Length)
= 2613.78 sqmm
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 90 of 91
Deff = 252 mm
Beff = 3350 mm
SPu = 21.3 kN/sqm
Vu = SPu X (Loff - d) X B
= 87.26 kN
φVc = 561.68 kN
Vu < φVc
= 236 mm
Critical Analysis Load Combination = 404
Critical Load Combination = [125] : 1.2 (LOAD 3: DL1)
+1.2 (LOAD 4: DL2) +0.5
(LOAD 5: LL1) +(LOAD 6:
LL2) +(LOAD 1: EX) +0.5
(LOAD 7: RLL)
Pu = 147.93 kN
Mux = -50.86 kNm
Muy = -26.74 kNm
P/A = 13.18 kN/sqm
Mx/Zx = -8.12 kN/sqm
My/Zy = -4.27 kN/sqm
Deff = 236 mm
Leff = 3350 mm
SPu = 17.45 kN/sqm
Vu = SPu X (Boff - d) X L
= 72.42 kN
φVc = 527.64 kN
Vu < φVc
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024
Footing Design: Design Calculation Page 91 of 91
Deff = 244 mm
Leff = 644 mm
Beff = 644 mm
Punching Perimeter = 2576 mm
Punching Area = 628544 sqmm
SPu = Average Pressure
= 14.75 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 159.43 kN
φVn = 1247.23 kN
φVc = 823.17 kN
No Shear
Vu < φVc Reinforcement
Required
file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmpF2D.tmp 12/31/2024