PRODUCT:DSE810
PC Software Configuration
D EEP SEA ELECTRON I CS
Interface
Issue 2
VH 06/06 /01
D ESCRIPTI O N
The 810 PC Software Configuration The main use of the software is to EDIT the
Interface is designed for use with the modules’ configuration to allow for use
DSE5xx, DSE5xxx, DSE4200 and with a particular application. Values such
DSE710/720 range of modules. It is as analogue trip and alarm levels, timers,
intended to be used in conjunction with input function selection, relay output
the DSE P810 For MS- Windows™ functions etc. can all be adjusted on the PC
configuration software. The interface screen and then ‘WRITTEN’ to the module.
enables the user to access the
For further details on using the software,
configuration stored within the module to
please refer to the P810 for Windows
allow changes to be made to the various
Software manual.
settings.
The interface kit comprises of:
► Interface module NOTE: The 810 module
► 25 way to 9 way RS232 adapter cable incorporates opto- isolation devices
► Interconnecting FCC 68- 8way cable within its construction. This ensures SPECIFIC A T I O N
which connects to the appropriate trouble free connection to earthed
connector on the module. desk- top type PC’s and laptops alike in
module configuration and generator DC SUPPLY :
► Software diskettes (or a CD) The 810 interface is powered from
testing environments. This allows it to
containing the P810 for Windows PC be used at distances up to 100 metres the module to which it is connected
software and various module away from the controller. so no external power supply is
configuration files to aid rapid required to the interface. The
module configuration. module however will need to be
connected to a suitable DC supply.
Also included on the disk is a MS Word™ NOTE: For full details of the DIMENSIONS :
template, this can be used to make configuration options available please 57mmx100mmx22mm
refer to the P810 for Windows Software
labels for the configurable LED’s on the OPERATING TEMPERATURE RANGE
manual.
module to identify their function. A slot :
is provided behind the clear window in = Telemetry and Control Available - 15 to +55 o C
the label for this, accessed by removing only to users of the optional INDICATIONS :
the front bezel. Communications Software.
The software will offer the user the
’Heart- beat’ on SCADA pages
following options: indicating Comms- link healthy.
PC REQUIREMENTS :
► LOAD previous configurations from 486 or better Processor
disk. Running MS- Windows 95™ or Later
► SAVE new configurations to disk. (NT4.0 or Later)
Minimum 16Mb memory
► READ the existing configuration from
Minimum 10Mb free hard disk space
the module. 640x480 Resolution VGA screen
► WRITE a new configuration to the CONNECTION :
module. The interface should be connected
► EDIT the configuration currently to the appropriate PC COM port on
loaded in the PC. your computer system and the
► PRINT the configuration currently FCC68- 8way cable inserted into the
loaded in the PC. socket on the rear of the module to
► View the ‘SCADA’ display from the be configured. The module being
module. configured will require a suitable DC
► SET- UP the software such as COM power supply connected to it.
port selection.
► QUIT back to Ms- Windows™.
► Set- up the Optional Remote
Telemetry & Control functions
Deep Sea Electronics plc maintains a policy of continuous development and reserves the right to change the details shown in this data sheet
without prior notice. The contents are intended for guidance only.
C ASE D I M E NSIO NS
FCC68 RS232
FCC68 RS232
42.0mm
57.0mm
100.0mm 22.0mm
T YPI C A L C O N NEC T I O NS
DC Supply N O TE: W hen connected to
Terminals
_ a com pleted Panel/G enset
+ Realtim e diagnostic
status display is available
810
Configuration
F
Up to 100 Metres Interface
To Socket on rear of module
157
808
550 or 555 Module
CE