Job Name: CSP-A700-VG Cut Sheet
Tag: MK-1
Quantity: 1
Printed Date: February 3, 2025
Model: CSP-A700-VG
Direct Drive Cabinet Fan
Standard Construction Features: Galvanized steel housing with duct collars. Centrifugal forward curved
wheel. Direct driven motor in the air stream.
0.6 0.06
Fan Configuration
Brake Horsepower (BHP)
Static Pressure (in. wg)
0.5 0.05
Drive type Direct 1 ,1
16
0.4 FR 0.04
P M
0.3 0.03
Performance
0.2 0.02
m
Requested Volume (CFM) 70
ste
0.1 0.01
Sy
Actual Volume (CFM) 71
Total External SP (in. wg) 0.51
0 0
Fan RPM 1,116 0 40 80 120 160 200 240 280 320 360 400
Operating Power (bhp) 0.05 Volume (CFM)
Startup Power (bhp) 0.05
Fan curve Static Pressure Calculations
FEI -
Brake horsepower curve External SP 0.5 in. wg
Air Stream Temp (F) 70
Direct Drive RPM Adjustment 0.01 in. wg
Start-up Temp (F) 70 Operating Point SP
Total External SP 0.51 in. wg
Air Density (lbs/ft^3) 0.075 Operating Bhp point
Elevation (ft) 39 Max system curve
Watts (W) 38 System curve
Static Efficiency (%) 11
Outlet Velocity (ft/min) 66
Sound
Motor Spherical Sones
Inlet 1.0
V/C/P 115/60/1
NEC FLA (Amps) 4.1
Min Circuit Ampacity (MCA) 5.1
Max Overload Production (MOP) 15
Greenheck Fan Corporation certifies that the model shown herein
is licensed to bear the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance with AMCA
Publication 211 and comply with the requirements of the AMCA
Certified Ratings Program.The AMCA certified ratings seal applies
to air performance ratings only.Performance certified is for
installation type D: Ducted inlet, ducted outlet.Power rating does
not include transmission losses.Performance ratings include the
effects of a backdraft damper.Speed (RPM) shown is nominal.
Performance is based on actual speed of test.The sound ratings
shown are loudness values in spherical sones at 1.5 m (5 ft) in a
spherical free field calculated per ANSI/AMCA 301.Values shown
are for installation Type D: ducted inlet spherical sone levels.
Ratings do not include the effects of duct end correction. Ratings
are based on 10 ft. of insulated duct.
Wattage is shown at free air. Wattage is approximate and may vary
between motors. Fan shaft input power (bhp) is not certified.
FLA - based on tables 150 or 148 of National Electric Code 2002. Actual
motor FLA may vary, for sizing thermal overload, consult factory.
MCA and MOP values shown only account for the motor, not accessories
(damper actuator, field supplied VFD, etc.).
Page 1 of 2 Version 3.10.0, January 2025
Job Name: CSP-A700-VG Cut Sheet
Tag: MK-1
Quantity: 1
Printed Date: February 3, 2025
Dimensions and Weights
Label Value Description
- 39 Weight w/o accessories (lbs)
A 12 Overall Height (in)
B 24 Overall Width (in)
C 12 Overall Length (in)
*All dimensions are in inches.
Page 2 of 2 Version 3.10.0, January 2025