WAS40P
Watch Alarm System
                                              Operating Instructions
D:\MIC40P\WAS40P\DOCUMENTS\B_WAS40P.bda.wpd
                                              STN ATLAS Marine Electronics GmbH
                                              Automation Systems
                                              Behringstraße 120
                                              D-22763 Hamburg
                                              © STN ATLAS Marine Electronics GmbH   30.03.2006   271.153 763.BDA   state of change: F Page 1 of 12
WAS40P
Watch Alarm System
Operating Instruction
Purpose
In this document, the operating instructions of the Watch Alarm System WAS40P with the
software version 1.25 are described.
Document Versions
This copy was printed on 30.03.2006 at 3:06 PM.
Version 1.00 of 25.09.1997, GOR
•   First issue.
Version 1.01 of 07.11.1997, GOR
•   Acoustic acknowledgement requested visually.
•   Document No. corrected.
Version 1.02 of 13.11.1997, GOR
•   Parameter "not selectable" for 1st cabin (master).
Version 1.03 of 02.12.1997, GOR
•   Title changed to WAS40P.
Version 1.10 of 07.05.1998, GOR
•   Every operating action on the WAS40P resets the watch alarm time.
•   A BAS40P alarm is also acknowledged acoustically from the WAS40P.
Version 1.11 of 27.11.1998, GOR
•   Times for external alarms changed.
Version 1.12 of 10.11.1999, GOR
•   Times for acoustical and optical watch preliminary alarm changed.
•   Lockable switch position added to output X1.18.
•   Name of collective and general alarm output changed.
Version 1.20 of 22.08.2000, GOR
•   Layout changed.
Version 1.21 of 01.02.2001, GOR
•   Document extension changed to .BDA, because .BDE are incompatible with our SAP
    System.
Version 1.22 of 16.07.2001, GOR
•   Error in chapter “Watch Alarm” corrected .
Version 1.23 of 30.03.2006, GOR
•   Appendix Operation with Automatic Mode Selector Switch added.
This manual is copyrighted and all rights are reserved. This document may not, in whole
or in part, be copied, photocopied, translated, or reduced to any electronic medium or
machine readable form without prior consent, in writing, from STN ATLAS Marine
Electronics company. The information in this manual is subject to change without notice.
© STN ATLAS Marine Electronics GmbH   30.03.2006   271.153 763.BDA   state of change: F Page 2 of 12
          WAS40P
          Watch Alarm System
          Operating Instruction
          Contents
Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Document Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1                 Panel View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2                 Status of Visual and Acoustical Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3                 Overview Plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4                 Watch Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5                 Officer’s Call . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6                 External Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7                 WAS Disabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
8                 Dimming / Lamp Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
9                 Lockable Switch OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
10                Appendix Operation with Automatic Mode Selector Switch . . . . . . . . . . . . . . . . . . . . 9
11                User Instruction - WAS Watch Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
12                User Instruction - WAS Officer Call . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
13                User Instruction - WAS System Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
          © STN ATLAS Marine Electronics GmbH                   30.03.2006       271.153 763.BDA           state of change: F Page 3 of 12
WAS40P
Watch Alarm System
Operating Instruction
1           Panel View
                                                                        DEAD MAN ALARM
                              DUTY OFFICERS                                 SYSTEM
                                                                                                          LED’s
                                            COLLECT                     1,5      OFF
                            MASTER
                                             CALL                       MIN                              Lockable Switch
                             CABIN           CABIN                       3             ALARM
                                                                                       RESET
                                                                                                         Reset-Key
                               1               2                        MIN
                             CABIN          CABIN                       12
                                                                        MIN
                                                                                                          Dimmer
                               3              4
                                                                                                          Lamp-Test
                             CABIN           CABIN
                                5              6
                        Cabin-Call-Key                 Time-Key         Acoustical and Optical Acknowledge-Key
© STN ATLAS Marine Electronics GmbH      30.03.2006   271.153 763.BDA   state of change: F Page 4 of 12
WAS40P
Watch Alarm System
Operating Instruction
2           Status of Visual and Acoustical Alarms
            State of the Time-Key LED's:
            FLASHING (green/yellow) - Visual Pre Alarm (Watch Alarm) -
                                         (starting 30 sec. before the
                                          Watch Alarm Time is running out)
            ON (green)                 - selected Watch Alarm Time
            OFF                        - not selected Watch Alarm Time
            State of the Alarm Reset LED's:
            ON (red)                   - Visual Pre Alarm Time (Watch Alarm) - time
                                         over (starting 25 sec. before the
                                         Watch Alarm Time is running out)
            OFF                        - no Alarm
            State of the ac. And opt. ackn. LED’s:
            FLASHING (red)               - Bridge Alarm is present (not acknowledged)
            OFF                          - no Bridge Alarm is present or acknowledged
            State of the Cabin Call LED’s:
            FLASHING (red)              - Cabin Call executed and not acknowledged
                                               at the cabin
            FLASHING (green)            - after switch ON:
                                           Cabin selected and not acknowledged
                                           at the cabin
            ON (green)                  - Cabin Call and Alarm possible, selected Cabin
                                           acknowledged at the Cabin, also after Cabin Call
                                           executed and acknowledged at the cabin
            OFF                         - Cabin Call and Alarm not possible
            State of the acoustical Alarm:
            BUZZER ON                    - Visual Pre Alarm Time (Watch Alarm) - time
                                              over (starting 25 sec. before the
                                               Watch Alarm Time is running out), or
                                         - Bridge Alarm is present (not acknowledged)
© STN ATLAS Marine Electronics GmbH   30.03.2006   271.153 763.BDA   state of change: F Page 5 of 12
WAS40P
Watch Alarm System
Operating Instruction
3           Overview Plan
                                                15W
                                                24V DC supply
               Ship's alarm system
               navigation system
               Extention panels
              Failure message to alarm system
              Collective alarm
              General alarm
              Horn in accommodation area
              Bridge and wing alarm
               Lockable switch
               (to harbour operation BAS40P)
                    Watch prealarm (option)
                                           Alarm from BAS
                                           Manuel alarm
© STN ATLAS Marine Electronics GmbH                  30.03.2006   271.153 763.BDA   state of change: F Page 6 of 12
WAS40P
Watch Alarm System
Operating Instruction
4           Watch Alarm
            The watch alarm system can be switched ON and OFF by means of a lockable
            switch. The OFF state does not begin until 1 minute after the lockable switch is set
            to OFF. During this time, a different time setting and different cabins can be
            selected. If all cabins are deselected here, the 1st cabin (master) is activated when
            switching ON occurs. It is possible by parameter to blocked the 1st cabin (master
            couldn’t deactivated). In the OFF state, all displays are dark and any activated
            alarm outputs are reset. The system monitoring function and thus the system fault
            output (X1.10-11) are active even in the OFF state.
            When the unit is switched on by means of the lockable switch, all operating
            elements are illuminated from behind, the preselected time is displayed (green LED
            in the time key) and the green LED of the selected cabin flashes. If the selection
            is accepted on the cabin panel by means of the acknowledgement key, the green
            LED changes over to continuous illumination. If the alarm reset is not performed
            on the unit within the selected time ( t-30 sec.) by operation of a key (and then
            releasing of the key again), or by operation of other connected units (e.g. BAS40P)
            or with one of the external acknowledgement-keys, then a preliminary alarm is
            given by flashing of the lamps in all connected acknowledgement keys and the time
            LED on the WAS40P. After a further 5 seconds have passed without
            acknowledgement, then the internal buzzer, the red LED 9 and the external
            buzzers in the reset panels are activated. If the system is not reset with one of the
            acknowledgement keys, then the subsequent alarm processes occur in the
            following steps. 25 seconds after the buzzers, the collective alarm (X1.12-13), as
            well as the buzzers and the alarm LED's in the selected cabin panels, are
            activated. The alarm cannot be reset on the cabin panels. After a further 30
            seconds, the general alarm (X1.14-15) follows.
            Via the input X2.21, the watch alarm can be triggered immediately, i.e. the
            collective alarm and the selected cabin-alarms occur immediately. The general
            alarm follows after 30 seconds unless resetting (acknowledgement) takes place
            before that.
            The times above are used if time program 1 are selected.
5           Officer’s Call
            The officer's call system of the WAS40P is active in the ON state only. By
            operation of the relevant key, a call can be sent to all cabins or to a particular one.
            On the WAS40P, the red LED of the called cabin flashes, and on the cabin panel
            the alarm LED and the buzzer are activated intermittently until an
            acknowledgement takes place on the cabin panel or the call is withdrawn by
            operation of the call key again.
© STN ATLAS Marine Electronics GmbH   30.03.2006   271.153 763.BDA   state of change: F Page 7 of 12
WAS40P
Watch Alarm System
Operating Instruction
6           External Alarm
            An external alarm that is present at X2.20 is signalled by the red flashing LED 18.
            After 5 second the internal buzzer are activated. If this alarm is not acknowledged
            within a further 25 seconds by means of the key K18, it is passed on to the
            selected officer, and the collected alarm (X1.12-13) is output. The general alarm
            (X1.14-15) follows after a further 30 seconds. If the alarm is acknowledged, it is
            displayed by continuous illumination for as long as it is present. If this alarm comes
            from a BAS40P, the acknowledgement key (K18) acoustically acknowledges the
            alarm there too.
            The delay times are the same as the times at the watch alarm function.
7           WAS Disabled
            If a voltage of +24 V is applied to the input X1.8, the system is disabled. In this
            mode, the outputs for the reset panels and cabin panels, the general alarm and the
            collective alarm are not active. The visual display goes off, and only the
            background illumination continues to run, but at the lowest dimming level. The only
            operating element that is active is the lockable switch (the unit can be switched off).
8           Dimming / Lamp Test
            The dimming level is adjusted by means of two dimming keys. Three dimming
            levels can be selected. Each of these dimming levels can be set in 16 steps via
            parameters. Dimming can also take place via a BAS40M connected to the Syn-IO
            line (X1.8).
            The lamp test is activated for 3 seconds by operation of the two dimming keys. In
            the lamp test, all red and green corner-LED's and the entire background
            illumination light up. Because the red and green corner-LED's light up, they appear
            yellow.
9           Lockable Switch OFF
            The position of the lockable switch is output on X1.18 (OFF = 24V). This signal
            could use for the input ‘harbour mode’ on the bridge alarm system.
© STN ATLAS Marine Electronics GmbH   30.03.2006   271.153 763.BDA   state of change: F Page 8 of 12
WAS40P
Watch Alarm System
Operating Instruction
10          Appendix Operation with Automatic Mode Selector Switch
            Recommend by the IMO Regulation MSC.128(75) the Bridge Navigational Watch
            Alarm System should be operational whenever the ship’s heading or track control
            system is engaged, unless inhibited by the master.
            Following operational modes are required:
              Manual OFF (Does not operate under any circumstances)
              Manual ON (In operation constantly)
              AUTOMATIC (Automatically brought into operation when ever the ship’s heading
              or track control system is activated)
            For fulfilment of this requirement the function of the WAP has to be extended with
            an Automatic Mode Selector Switch.
            The Automatic Mode Selector Switch is also key operated (the same key as for the
            ON/OFF switch of the WAP is used).
            Principle of operation - Watch Alarm Panel with Automatic Mode
            Selector Switch:
            Master ON/OFF switch is the key operated switch at the WAP.
              If this is OFF the system is off.
              If this is ON the operation is dependent on the Automatic Mode Selector Switch:
              If the AMS switch is open, the WAP is always ON. (Standard Mode)
              If the AMS switch is closed, the WAP is ON only when autopilot is selected.
              (Auto Mode)
© STN ATLAS Marine Electronics GmbH   30.03.2006   271.153 763.BDA   state of change: F Page 9 of 12
WAS40P
Watch Alarm System
Operating Instruction
11               User Instruction - WAS Watch Alarm
      Event                             Time              Watch            Operatio     Display WAP                                Display Cabin             Alarm-Extern               Necessary Operation
                                                          Alarm-/Reset     n WAP                                                   Alarm-Panel
                                                          Key
 0    Unit OFF                          ->                ->               Lockable
                                                                           switch OFF
 1    Unit ON - switching on            ->                ->               Lockable
      -see Systems Settings                                                switch ON
 2    Unit ON                           ->                background       ->           - Unit label illuminated                   Unit label illuminated
                                                          illuminated                   - Cabin keys illuminated
                                                                                        - Time key LED green
 3    Watch Alarm - pre alarm (opt.)    30 sec. before    - flashing       ->           - Time key LED flashing yellow, green                                                           - Watch Alarm-/ Reset Key or
                                        Watch Alarm                                                                                                                                     - Alarm Reset at the WAP or
                                                                                                                                                                                        - Keyboard at the NACOS
 4    Watch Alarm - pre alarm           25 sec. before    - flashing       ->           - Time Key - LED flasheing                                                                      - Watch Alarm-/ Reset Key or
      (opt. + acou.)                    Watch Alarm       - acou. alarm    ->             yellow, green                                                                                 - Alarm Reset at the WAP or
                                                                                        - Alarm Reset - LED flashing red                                                                - Keyboard at the NACOS
                                                                                        - acou. Alarm
 5    Watch Alarm -> A.P. Cabin         time over         - flashing       ->           - Time Key - LED flasheing yellow, green   - Alarm Key               - Collective alarm -> ON   - Watch Alarm-/ Reset Key or
                                        Watch Alarm       - acou. alarm    ->           - Alarm Reset - LED flashing red             illuminated                                        - Alarm Reset at the WAP or
                                                                                        - acou. Alarm                              - acou. alarm                                        - Keyboard at the NACOS
 6    Watch Alarm -> Collective Alarm   30 sec. after     - flashing       ->           - Time Key - LED flasheing                 - Alarm Key               - Collective alarm -> ON   - Watch Alarm-/ Reset Key or
                                        Watch Alarm       - acou. alarm    ->             yellow, green                              illuminated             - General alarm -> ON      - Alarm Reset at the WAP or
                                                                                        - Alarm Reset - LED flashing red           - acou. alarm                                        - Keyboard at the NACOS
                                                                                        - acou. Alarm
 7    Bridge Alarm -> WAS (opt.)        0 sec. After      ->               ->           - Alarm Reset -LED flashing red                                                                 - Alarm Reset at the WAP or
                                        Bridge Alarm                                                                                                                                    - BAP: ackn. acou. + opt. alarm
                                                                                                                                                                                        -NACOS: ackn. Acou. + opt. alarm
 8    Bridge Alarm -> WAS               5 sec. After      ->               ->           - Quit Key - LED flashing red                                                                   - Alarm Reset at the WAP or
      (opt. + acou.)                    Bridge Alarm                                    - acou. alarm                                                                                   - BAP: ackn. acou. + opt. alarm
                                                                                                                                                                                        -NACOS: ackn. Acou. + opt. alarm
 9    Bridge Alarm -> WAS ->            30 sec. After     ->               ->           - Quit Key - LED flashing red              - Alarm Key illuminated   Collective alarm -> ON     - Alarm Reset at the WAP or
      A.P. Cabin                        Bridge Alarm                                    - acou. alarm                              - acou. alarm                                        - BAP: ackn. acou. + opt. alarm
                                                                                                                                                                                        -NACOS: ackn. Acou. + opt. alarm
 10   Bridge Alarm -> WAS ->            60 sec. After     ->               ->           - Quit Key - LED flashing red              - Alarm Key illuminated   Collective alarm -> ON     - Alarm Reset at the WAP or
      Collective Alarm                  Bridge Alarm                                    - acou. alarm                              - acou. alarm             General alarm -> ON        - BAP: ackn. acou. + opt. alarm
                                                                                                                                                                                        -NACOS: ackn. Acou. + opt. alarm
© STN ATLAS Marine Electronics GmbH                      30.03.2006       271.153 763.BDA         state of change: F                                                                                         Page 10 of 12
WAS40P
Watch Alarm System
Operating Instruction
12          User Instruction - WAS Officer Call
                  Event                                 Operation Cabin Alarm Panel              Operation WAP            Display WAP                           Display Cabin Alarm Panel
             0    Unit OFF                              ->                                       Lockable switch OFF
             1    UNIT ON - switching ON                ->                                       Lockable switch ON
                  - see System Settings
             2    Unit ON                               ->                                       ->                       Unit label illuminated                Unit label illuminated
                                                                                                                          Cabin keys illuminated
                                                                                                                          “selectable cabin keys: LED’s green
             3a   WAP: call officer(s) ->               ->                                       1st key operation for:   “pressed”                             “called” Alarm Panel(s):
                                                                                                 - Captain                Cabin Keys - LED(s) flashing red      - Alarm Display flashing
                                                                                                 - Collective call                                              - acou. alarm (intermittent)
                                                                                                 - Cabin 1 to 6
             3b   A.P.: officer(s) acknowledgement ->   operation key: -Call acknowledge ->      ->                       “acknowledged”                        “acknowledged” Alarm Panel(s):
                                                                                                                          Cabin Keys - LED(s) green             - Alarm Display OFF
                                                                                                                                                                - acou. alarm OFF
                                                                                                                          “Not acknowledged”                    “not acknowledged” Alarm Panel(s):
                                                                                                                          Cabin Keys - LED(s) flashing red      - Alarm Display flashing
                                                                                                                                                                - acou. alarm (intermittent)
             4a   WAP: call officer(s) ->               ->                                       1st key operation for:   “pressed”                             “called” Alarm Panel(s):
                                                                                                 - Captain                Cabin Keys - LED(s) flashing red      - Alarm Display flashing
                                                                                                 - Collective call                                              - acou. alarm (intermittent)
                                                                                                 - Cabin 1 to 6
             4b   WAP: call withdraw ->                 ->                                       1st key operation for:   “again pressed”                       “again called” Alarm Panel(s):
                                                                                                 - Captain                Cabin Keys - LED(s) green             - Alarm Display OFF
                                                                                                 - Collective call                                              - acou. alarm OFF
                                                                                                 - Cabin 1 to 6
© STN ATLAS Marine Electronics GmbH                30.03.2006      271.153 763.BDA            state of change: F                                                                                 Page 11 of 12
WAS40P
Watch Alarm System
Operating Instruction
13            User Instruction - WAS System Adjustment
         Event                                                     Time                     Operation               Operation WAP                        Display WAP                                         Display Cabin Alarm
                                                                                            Cabin Alarm                                                                                                      Panel
                                                                                            Panel
     0   Unit OFF                                                  ->                       ->                      Lockable switch OFF
     1   Unit ON - switching ON ->                                 ->                       ->                      Lockable switch ON                   Unit label illuminated                              Unit label illuminated
                                                                                                                                                         Cabin Keys illuminated
                                                                                                                                                         - Cabin Keys - LED(s) flashing green
                                                                                                                                                         - Time Key - LED green (standard)
     2   Cabin (Alarm Panels) activated ->                         ->                       press Key:              ->                                   - Cabin Keys - LED green (activated)                Unit label illuminated
         (after switching ON)                                                               - Call Acknowledge ->                                        - Cabin Keys - LED flashing green (not activated)
                                                                                                                                                         - Time Key - LED green (standard)
     3   Adjustment: Time until Watch Alarm ->                     60 sec. for alteration   ->                      - Lockable switch OFF                (activated for 60 sec. after switching OFF)         (Activated for 60 sec. after
         (switch OFF the unit)                                     (after switching OFF)                            - press Time Key for                 - Unit label illuminated                            switching OFF)
                                                                                                                      - selection the Watch Alarm Time   - Cabin Keys illuminated                            Unit label illuminated
                                                                                                                                                         - Cabin Keys - LED green (activated)
                                                                                                                                                         - Time Key - LED green (selected time)
     4   Adjustment: Cabin selection (for alarm transfer) ->       60 sec. for alteration   ->                      - Lochable switch OFF                (activated for 60 sec. after switching OFF)         (Activated for 60 sec. after
         (switch OFF the unit)                                     (after switching OFF)                            - press Key for                      - Unit label illuminated                            switching OFF)
                                                                                                                      - Captain                          - Cabin Keys illuminated                            Unit label illuminated
                                                                                                                      - Collective Call                  - Cabin Keys - LED green (activated)
                                                                                                                      - Cabin 1 to 6                     - Time Key - LED green (selected time)
              References
                            WAS40P Functional description, 271.153 763.BGE