Ankle Fracture Management System
Ankle Fracture Management System
MANAGEMENT SYSTEM
Ankle Fracture Management System
Introduction
Ankle fractures are frequently complicated by variables out of the surgeon’s control.
The amount of comminution, degree of osteoporosis, location of the fracture, and size
of the patient can all lead to challenging obstacles. The Ankle Fracture Management
System was developed to be the most comprehensive set available for the treatment
of common injuries. Improved basic small fragment implants and instrumentation,
anatomic plates, and locking-screw technology, allow for confident and effective
treatment of the majority of fracture patterns.
This set was designed to give the surgeon the armamentarium to more effectively
address any patient/injury pattern encountered. Significant time and research were
invested to develop anatomic plates, with specific emphasis placed on determining the
appropriate angle of the locked screws. This allows for easier and faster implantation,
while negating the need for more expensive “variable-angle” locking plates and screws.
All plates designed for use on the fibula have modifications that allow for easier
use of either the TightRope® or syndesmotic screws for stabilization of associated
ligamentous injuries.
Complex Fibular Fracture Plates
The Complex Fibular Fracture Plates, otherwise known as the
Locking Distal Fibular Plates, are designed for use in the most
challenging lateral malleolus fractures. The distal portion or head
of the plate thins and spreads to encompass a large portion of
the lateral malleolus. The head accepts multiple 2.7 mm locking
screws or 3 mm cancellous screws, making this plate ideal
for patients with highly comminuted lateral malleolus fractures,
osteoporotic bone, obesity, or open injuries with associated bone
loss. Included are divergent angle screw holes that increase
biomechanical stability and provide for more secure fixation.
The shaft portion of the plate thickens to improve rigidity and
strength, and the multi-functional screw holes allow for multiple
screw options. As with all of the fibular plates, there are recessed
screw holes and a scalloped perimeter, which allows for easier
contouring and Knotless TightRope/screw placement outside of
the plate, as necessary.
Aiming Guide
1 2
3
Locking Third Tubular Plates
Low profile plates are designed for use with the majority
of fibular fractures. The scalloped design allows for easier
contouring and placement of TightRope/screws outside of
the plate, when necessary. The arch maintains strength while
decreasing surface contact with the periosteum, preserving
blood supply. All screw holes accept 3.5 mm nonlocking
cortical, 3.5 mm locking, or 4 mm cancellous screws. Nested
slots at the screw holes lessen screw head prominence and
allow the TightRope’s circular button to fit snugly.
4 mm
nonlocking 3.5 mm
3.5 mm
cancellous nonlocking
locking
cortical
TightRope Fixation
A) Through Plate; B) Posterior Placement
1 2
2a 2b
Locking Medial Hook Plates
The Locking Medial Hook Plate is designed to treat extreme
distal or comminuted medial malleolus fractures. The two-hooked,
distal prongs are designed to corporate the deltoid ligament
attachment, affording secure fixation of these small fragments (akin
to using the rotator cuff in assisting greater tuberosity fixation in
the shoulder). The prongs are spaced and recessed appropriately
to allow for placement of a 4 mm cancellous screw, if desired.
As these small fragments typically do not permit the placement of
two 4 mm screws, this plate improves the strength of fixation and
improves rotational control. The proximal screw holes allow for the
placement of 3.5 mm nonlocking cortical screws, 3.5 mm locking
screws, or 4 mm cancellous screws and 2.7 mm locking or 3.0 mm
cancellous distally.
OR
Note: Impaction of the tines into bone is
NOT mandatory, and is not required to
achieve adequate stability of the distal
fragment. It is acceptable to leave the
hooks slightly proud.
OR
1 2
OR
3 4
Introducing
the Family of
Ankle Fracture
Management
Products
Offering multiple fixation solutions, the Ankle Fracture Distal Tibia Screw
Case (pictured below) is an auxiliary container which complements and
may be added to the system to fulfill the needs of the surgeon when
considering more complex cases. The AR-8943C-31 case is currently
available and houses both solid and cannulated cortical screws,
cancellous screws, as well as a wider range of sizes of those screws
already found in the main set (AR-8943S, pictured left).
2.7 mm Locking
2.7 mm Cortical
3.0 mm Cancellous
3.5 mm Locking
3.5 mm Cortical
4.0 mm Short Thread
4.0 mm Long Thread
4.0 mm Cannulated Short Thread
4.0 mm Cannulated Long Thread
4.0 mm Cancellous
Syndesmosis Clamp
(attached to lid)
LEVEL 2
Implant Tray
Screw Caddy
with Washers
LEVEL 1
Instruments in Case
Ankle Fracture Management System—AR-8943S
RECOMMENDED SET RECOMMENDED SET RECOMMENDED SET RECOMMENDED SET
Implants LENGTH PRODUCT # Implants LENGTH PRODUCT #
CONTENT, AR-8943C CONTENT, AR-8943C-31 CONTENT, AR-8943C CONTENT, AR-8943C-31
2.7 mm Low Profile Screw™, Locking 3.5 mm Low Profile Screw, Nonlocking, Cortical
10 mm AR-8827L-10 4 8 10 mm AR-8835-10 3 6
12 mm AR-8827L-12 4 8 12 mm AR-8835-12 6 6
14 mm AR-8827L-14 4 8 14 mm AR-8835-14 6 6
16 mm AR-8827L-16 4 8 16 mm AR-8835-16 6 6
18 mm AR-8827L-18 4 8 18 mm AR-8835-18 6 6
20 mm AR-8827L-20 4 8 20 mm AR-8835-20 3 6
22 mm AR-8827L-22 4 8 22 mm AR-8835-22 3 6
24 mm AR-8827L-24 4 8 24 mm AR-8835-24 3 6
26 mm AR-8827L-26 4 8 26 mm AR-8835-26 3 6
28 mm AR-8827L-28 4 8 28 mm AR-8835-28 3 6
30 mm AR-8827L-30 4 8 30 mm AR-8835-30 3 6
32 mm AR-8835-32 * 4
34 mm AR-8835-34 * 4
2.7 mm Low Profile Screw, Nonlocking, Cortical 35 mm AR-8835-35 3 N/A
10 mm AR-8827-10 3 3 36 mm AR-8835-36 * 4
12 mm AR-8827-12 3 3 38 mm AR-8835-38 * 4
14 mm AR-8827-14 3 3 40 mm AR-8835-40 3 4
16 mm AR-8827-16 3 3 42 mm AR-8835-42 * 4
18 mm AR-8827-18 3 3 44 mm AR-8835-44 * 4
20 mm AR-8827-20 3 3 45 mm AR-8835-45 3 4
22 mm AR-8827-22 3 3 46 mm AR-8835-46 * 4
24 mm AR-8827-24 3 3 48 mm AR-8835-48 * 4
26 mm AR-8827-26 3 3 50 mm AR-8835-50 3 4
28 mm AR-8827-28 3 3 52 mm AR-8835-52** * 4
30 mm AR-8827-30 3 3 54 mm AR-8835-54** * 4
32 mm AR-8827-32 3 3 55 mm AR-8835-55 3 4
34 mm AR-8827-34 3 3 56 mm AR-8835-56** * 4
36 mm AR-8827-36 3 2 58 mm AR-8835-58** * 4
38 mm AR-8827-38 2 2 60 mm AR-8835-60 3 4
40 mm AR-8827-40 2 2
42 mm AR-8827-42 2 2
3.5 mm Low Profile Screw, Locking
44 mm AR-8827-44 2 2
46 mm AR-8827-46 2 2 10 mm AR-8835L-10 6 6
48 mm AR-8827-48 2 2 12 mm AR-8835L-12 6 6
50 mm AR-8827-50 2 2 14 mm AR-8835L-14 6 6
52 mm AR-8827-52 2 2 16 mm AR-8835L-16 6 6
54 mm AR-8827-54 2 2 18 mm AR-8835L-18 3 6
56 mm AR-8827-56 2 2 20 mm AR-8835L-20 3 6
60 mm AR-8827-60 2 2 22 mm AR-8835L-22 * 6
24 mm AR-8835L-24 * 6
26 mm AR-8835L-26 * 6
3 mm Low Profile Screw, Cancellous 28 mm AR-8835L-28 * 6
10 mm AR-8830-10 4 5 30 mm AR-8835L-30 * 6
12 mm AR-8830-12 4 5 32 mm AR-8835L-32 * 6
14 mm AR-8830-14 4 5 34 mm AR-8835L-34 * 6
16 mm AR-8830-16 4 5 36 mm AR-8835L-36 * 6
18 mm AR-8830-18 4 5 38 mm AR-8835L-38 * 6
20 mm AR-8830-20 4 5 40 mm AR-8835L-40 * 6
22 mm AR-8830-22 4 5 42 mm AR-8835L-42 * 6
24 mm AR-8830-24 4 5 44 mm AR-8835L-44 * 6
26 mm AR-8830-26 4 5 45 mm AR-8835L-45 * 6
28 mm AR-8830-28 4 5 46 mm AR-8835L-46 * 6
30 mm AR-8830-30 4 5 48 mm AR-8835L-48 * 6
50 mm AR-8835L-50 * 6
4 mm Low Profile Screw, Nonlocking, Cancellous 4 mm Low Profile Screw, Long Thread, Cannulated
10 mm AR-8840-10 3 6 30 mm AR-8840CL-30 4 4
12 mm AR-8840-12 3 6 32 mm AR-8840CL-32 * 4
14 mm AR-8840-14 3 6 34 mm AR-8840CL-34 * 4
16 mm AR-8840-16 3 6 35 mm AR-8840CL-35 4 N/A
18 mm AR-8840-18 3 6 36 mm AR-8840CL-36 * 4
20 mm AR-8840-20 3 6 38 mm AR-8840CL-38 * 4
22 mm AR-8840-22 3 6 40 mm AR-8840CL-40 4 4
24 mm AR-8840-24 3 6 42 mm AR-8840CL-42 * 4
26 mm AR-8840-26 * 6 44 mm AR-8840CL-44 * 4
28 mm AR-8840-28 * 6 45 mm AR-8840CL-45 4 N/A
30 mm AR-8840-30 * 6 46 mm AR-8840CL-46 * 4
32 mm AR-8840-32 * 3 48 mm AR-8840CL-48 * 4
34 mm AR-8840-34 * 3 50 mm AR-8840CL-50 4 4
36 mm AR-8840-36 * 3 55 mm AR-8840CL-55 4 4
38 mm AR-8840-38 * 3 60 mm AR-8840CL-60 4 4
40 mm AR-8840-40 * 3
4 mm Low Profile Screw, Short Thread
42 mm AR-8840-42 * 3
44 mm AR-8840-44 * 3 30 mm AR-8840P-30 * 3
45 mm AR-8840-45 * 3 32 mm AR-8840P-32 * 3
46 mm AR-8840-46 * 3 34 mm AR-8840P-34 * 3
48 mm AR-8840-48 * 3 36 mm AR-8840P-36 * 3
50 mm AR-8840-50 * 3 38 mm AR-8840P-38 * 3
55 mm AR-8840-55 * 3 40 mm AR-8840P-40 * 3
60 mm AR-8840-60 * 3 42 mm AR-8840P-42 * 3
44 mm AR-8840P-44 * 3
46 mm AR-8840P-46 * 3
4 mm Low Profile Screw, Short Thread, Cannulated 48 mm AR-8840P-48 * 3
30 mm AR-8840C-30 4 4 50 mm AR-8840P-50 * 3
32 mm AR-8840C-32 * 4 55 mm AR-8840P-55 * 3
34 mm AR-8840C-34 * 4 60 mm AR-8840P-60 * 3
35 mm AR-8840C-35 4 N/A
36 mm AR-8840C-36 * 4
4 mm Low Profile Screw, Long Thread
38 mm AR-8840C-38 * 4
40 mm AR-8840C-40 4 4 30 mm AR-8840PL-30 * 3
42 mm AR-8840C-42 * 4 32 mm AR-8840PL-32 * 3
44 mm AR-8840C-44 * 4 34 mm AR-8840PL-34 * 3
45 mm AR-8840C-45 4 N/A 36 mm AR-8840PL-36 * 3
46 mm AR-8840C-46 * 4 38 mm AR-8840PL-38 * 3
48 mm AR-8840C-48 * 4 40 mm AR-8840PL-40 * 3
50 mm AR-8840C-50 4 4 42 mm AR-8840PL-42 * 3
55 mm AR-8840C-55 4 4 44 mm AR-8840PL-44 * 3
60 mm AR-8840C-60 4 4 46 mm AR-8840PL-46 * 3
48 mm AR-8840PL-48 * 3
50 mm AR-8840PL-50 * 3
55 mm AR-8840PL-55 * 3
60 mm AR-8840PL-60 * 3
RECOMMENDED
Washer DIAMETER PRODUCT # SET CONTENT
Washer 7 mm AR-8870W 6
Inventory Control Form: Ankle Fracture Management—AR-8943S
© 2014, Arthrex Inc. (USA) LF1-0439-EN_F; To Order Call: 1-800-934-4404 or Fax: 800-643-9310
Hospital:
Surgeon:
AR-8943T-04 4 AR-8943C-04 4
AR-8943T-05 5 AR-8943C-06 6
AR-8943T-06 6 AR-8943C-07 7
AR-8943T-07 7 AR-8943C-08 8
AR-8943T-08 8 AR-8943C-10 10
AR-8943T-10 10 AR-8943C-12 12
AR-8943T-12 12
AR-8943TH-03 3 AR-8943H-03 3
AR-8943TH-05 5 AR-8943H-05 5
AR-8943TH-07 7 AR-8943H-07 7
Locking Distal Fibula Plate, Left Locking Distal Fibula Plate, Right
QTY PRODUCT # HOLES PRICE LOT # QTY PRODUCT # HOLES PRICE LOT #
AR-8943BL-04 4 AR-8943BR-04 4
AR-8943BL-05 5 AR-8943BR-05 5
AR-8943BL-06 6 AR-8943BR-06 6
AR-8943BL-08 8 AR-8943BR-08 8
AR-8943BLS-10** 10 AR-8943BRS-10** 10
AR-8943BLS-12** 12 AR-8943BRS-12** 12
AR-8943BLS-14 ** 14 AR-8943BRS-14** 14
AR-8943-01 Guidewire w/Trocar Tip, .053” (1.35 x 150 mm) AR-8943-16 2 mm Drill Bit, graduated
AR-8943-38 Guidewire w/Trocar Tip, threaded, .053” (1.35 x 150 mm) AR-8943-13 2.5 mm Drill Bit, graduated
AR-8941K Guidewire w/Trocar Tip, .062” (1.6 x 150 mm) AR-8943-02 2.6 mm Drill Bit, cannulated
AR-8945K Guidewire w/Trocar Tip, .078” (2 x 130 mm) AR-8943-30 2.5 mm Drill Bit
AR-13226 BB-Tak AR-8943-36 3 mm Drill Bit
AR-13226T BB-Tak, threaded AR-4160-35 3.5 mm Drill Bit
AR-8943-42 2.5 mm Drill Bit, graduated, laser marked at 3.5˝
AR-8827D-01 2.7 mm Drill Bit
**Sterile
Inventory Control Form: Ankle Fracture Management—AR-8943S
© 2014, Arthrex Inc. (USA) LF1-0439-EN_F; To Order Call: 1-800-934-4404 or Fax: 800-643-9310
2.7 mm, Locking 3 mm, Cancellous 3.5 mm, Cortical 3.5 mm, Locking
QTY PRODUCT # LENGTH QTY PRODUCT # LENGTH QTY PRODUCT # LENGTH QTY PRODUCT # LENGTH
*Housed in auxiliary Ankle Fracture Screw Set only, AR-8943C-31. Codes without* are housed in both AR-8943C and AR-8943C-31.
Inventory Control Form: Ankle Fracture Management—AR-8943S
© 2014, Arthrex Inc. (USA) LF1-0439-EN_F; To Order Call: 1-800-934-4404 or Fax: 800-643-9310
4 mm, Short Thread 4 mm, Long Thread 4 mm, Short Thread, Cannulated 4 mm, Long Thread, Cannulated
QTY PRODUCT # LENGTH QTY PRODUCT # LENGTH QTY PRODUCT # LENGTH QTY PRODUCT # LENGTH
*Housed in auxiliary Ankle Fracture Screw Set only, AR-8943C-31. Codes without* are housed in both AR-8943C and AR-8943C-31.
For more information:
http://www.anklefxsystem.arthrex.com
This description of technique is provided as an educational tool and clinical aid to assist properly licensed
medical professionals in the usage of specific Arthrex products. As part of this professional usage, the medical
professional must use their professional judgment in making any final determinations in product usage and
technique. In doing so, the medical professional should rely on their own training and experience and should
conduct a thorough review of pertinent medical literature and the product’s Directions For Use.