0% found this document useful (0 votes)
33 views2 pages

HV 1

The document outlines the general notes and key items related to tenant scope of work for a construction project, including various systems such as hot water heaters, lighting controls, and fire alarms. It also includes references to structural drawings and specifications for elements like frost slabs and gas meter locations. Additionally, it highlights the need for shop drawings and coordination with structural designs for specific installations.

Uploaded by

wdgrupdisticaret
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views2 pages

HV 1

The document outlines the general notes and key items related to tenant scope of work for a construction project, including various systems such as hot water heaters, lighting controls, and fire alarms. It also includes references to structural drawings and specifications for elements like frost slabs and gas meter locations. Additionally, it highlights the need for shop drawings and coordination with structural designs for specific installations.

Uploaded by

wdgrupdisticaret
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

GENERAL NOTES KEY NOTES

1. FOR ENLARGED SUITE PLANS REFER TO A-700S DWG'S 1 LINE OF ROOF ABOVE
2. LIST OF ITEMS IN TENANT SCOPE OF WORK:
2 FROST SLAB (REFER TO STRUCT. DWGS)
2.1. HOT WATER HEATERS AND RELATED SYSTEMS AND
PUMPS RAIN WATER LEADER, C/W ACCESS PANEL, (REFER
3
2.2. LIGHTING CONTROL SYSTEMS TO MECHANICAL)
2.3. ENTRYPHONE/ACCESS CONTROL SYSTEMS
4 STRUCTURAL BRACING (REFER TO STRUC. DWGS)
2.4. SUITES DOOR SECURITY CIRCUITS
2.5. SUITES MEDIA PANELS GAS METER LOCATION, (C/W BOLLARDS AS PER GAS
5
2.6. INTERCONNECT SMOKE ALARMS METER SPECS.)
2.7. FIRE ALARM SYSTEMS
6 SIAMESE CONNECTION
2.8. TEL/CATV
2.9. RANGE HOODS, EXHAUST FANS 7 AUTOMATIC DOOR OPENER C/W PUSH BUTTONS
2.10. PLUMBING FIXTURES
8 EXTERIOR SOFFIT LIGHT ABOVE
2.11. EXPANSION TANKS
2.12. ELECTRICAL FIXTURES, FANS, CONTROLS 9 ROOF HATCH ABOVE

ROOF ACCESS METAL SERVICE STAIR FOR


10 REFERENCE ONLY. SHOP DRAWINGS TO BE
PROVIDED.

11 ROOF BELOW

12 EXTERIOR SOFFIT LIGHT ABOVE

BALCONY SCUPPER (REFER TO ROOF SCUPPER


13 DETAIL). CONCRETE TOPPING TO ACHIEVE DRAIN
SLOPE.

BALCONY PRIVACY PARTITION (TO ALLOW


14
UNDISTURBED WATER DRAINAGE)

15 NON-FROST HOSE BIB

16 NOT USED

ACCESSIBLE ROLL-INN SHOWER, GC TO


17
COORDINATE SLAB DEPRESSION WITH STR. DWG'S

4 1
A-301 A-401

1 2 4 4.1 6 7 8 8.1 10 11 12 13
8'-6" 10'-0" 19'-81 2" 19'-81 2" 20'-6" 18'-5" 36'-8" 18'-4" 18'-11 2" 18'-11 2" 2'-0"

8'-6" 10'-0" 152'-111 2"

101 4" TYPICAL EAST FACING 101 4"


SUITE DIMENSIONS
TYP TYP TYP TYP
13 12 14 13 13 14 12 13
A TYP 1'-3"
13
A
14
1'-0"
1'-6"

1'-6"
BALCONY BALCONY
B BALCONY BALCONY
3
BALCONY BALCONY
B
2'-63 4" 6'-0" 5'-0" 3'-4" 6'-0" 3'-1" BALCONY BALCONY
A-405
4'-0"

4'-0"
5'-1"

5'-1"
WE5 WE5 WE5
3'-0"

2'-6"
1'-5"

4'-0"
C C

101 4"
R2 WE5 H H H H H H H H
4'-0"

W8 W8 W8 W8 TYP W8 W8 W8 W8 WE5
11 2
9'-11"

9'-11"
A-503 4'-0"
W7a PW4

18'-53 8"
1 4'-0" PW4 PW4 PW4 PW4 PW4 PW4 PW4
4'-0" 3'-63 8"
D D
12'-0"

HOUSE KING KING KING KING KING KING KING KING


WE5 KEEPING 4
3 WE2 SUITE SUITE SUITE SUITE SUITE SUITE SUITE SUITE
200
7'-6"

8'-6" 201 203 205 207 209 211 213 215 WE3A

8'-11"
A-501 1
E P10
3
2'-0 8" A-301
4'-0" 1'-91 4"
1'-5"

2 F 200 F
W7 SA-03
A-301 STAIR ELEVATOR WE3A
P8

5'-0"

5'-0"
A LOBBY PW3 CORRIDOR PW3 P9
7'-7"

P9 TYP. TYP.

12'-101 2"

10'-9"
P8 7 7
P5 2
G WE2 A-401
2 ELEVATOR PW5 PW3
6'-5"

F1
16'-11 4"

A-401 ACC KING ACC KING KING KING KING KING KING
P5 17 SUITE L SUITE SUITE SUITE SUITE SUITE SUITE L
202 204 206 208 210 212 5'-2" 214 2'-03 8"
G1
2'-75 8"

1
4'-9"

SIM P10 WE3A


WE2

14'-6"
PW4 PW4 PW4 PW4 PW4

14'-55 8"
WE4
H
71 2"

4 SB-02
WE5 A-405
6'-9"

1'-87 8"
6'-6"

W9a
1'-27 8"

4 I WE5
6'-6"

W9a W9a W9a W9a W9a W9a


W8a W8a W8a
BALCONY I H H H H
J J
4'-2"
4'-2"

4'-0"
10'-21 2" 5'-27 8" 3'-05 8" 5'-0" 3'-4" 5'-0" 3'-4" 5'-0" 3'-4" 5'-0" 3'-0" 6'-9" 3'-4" 5'-0" 5'-0" 3'-9" 6'-0" 6'-0" 3'-9" 5'-0" 5'-0" 3'-9" 6'-0" 3'-11 4"

4'-2"
WE5
7'-6"

7'-6"
5'-91 2"
BALCONY 31 4"
1'-111 2" 14'-51 2" WE2
4'-05 8" WE5
WE5 BALCONY WE5 4'-01 4" BALCONY 4'-21 8" BALCONY BALCONY BALCONY
K K

16'-0"
5 STAIR
TYP
14 A-405 B

10'-21 2"
TYPICAL WEST FACING
8'-6"

8'-6"
WE2
SUITE DIMENSIONS WE2

WE2

101 4"
L L
101 4"

22'-7" 4 18'-11 2"


A-502
3 1 WE2
2'-0" 6'-10" A-301 A-401 2'-9" 18'-11 2"

DRAWING TITLE

1 2 3 4 4.1 5 6 7 8 8.1 9 10 11 12 SECOND FLOOR PLAN


GUEST ACCOMMODATION
GENERAL NOTES KEY NOTES
1. FOR ENLARGED SUITE PLANS REFER TO A-700S DWG'S 1 LINE OF ROOF ABOVE
2. LIST OF ITEMS IN TENANT SCOPE OF WORK:
2 FROST SLAB (REFER TO STRUCT. DWGS)
2.1. HOT WATER HEATERS AND RELATED SYSTEMS AND
PUMPS RAIN WATER LEADER, C/W ACCESS PANEL, (REFER
3
2.2. LIGHTING CONTROL SYSTEMS TO MECHANICAL)
2.3. ENTRYPHONE/ACCESS CONTROL SYSTEMS
4 STRUCTURAL BRACING (REFER TO STRUC. DWGS)
2.4. SUITES DOOR SECURITY CIRCUITS
2.5. SUITES MEDIA PANELS GAS METER LOCATION, (C/W BOLLARDS AS PER GAS
5
2.6. INTERCONNECT SMOKE ALARMS METER SPECS.)
2.7. FIRE ALARM SYSTEMS
6 SIAMESE CONNECTION
2.8. TEL/CATV
2.9. RANGE HOODS, EXHAUST FANS 7 AUTOMATIC DOOR OPENER C/W PUSH BUTTONS
2.10. PLUMBING FIXTURES
8 EXTERIOR SOFFIT LIGHT ABOVE
2.11. EXPANSION TANKS
2.12. ELECTRICAL FIXTURES, FANS, CONTROLS 9 ROOF HATCH ABOVE

ROOF ACCESS METAL SERVICE STAIR FOR


10 REFERENCE ONLY. SHOP DRAWINGS TO BE
PROVIDED.

11 ROOF BELOW

12 EXTERIOR SOFFIT LIGHT ABOVE

BALCONY SCUPPER (REFER TO ROOF SCUPPER


13 DETAIL). CONCRETE TOPPING TO ACHIEVE DRAIN
SLOPE.

BALCONY PRIVACY PARTITION (TO ALLOW


14
UNDISTURBED WATER DRAINAGE)

15 NON-FROST HOSE BIB

16 NOT USED

ACCESSIBLE ROLL-INN SHOWER, GC TO


17
COORDINATE SLAB DEPRESSION WITH STR. DWG'S

4 1
A-301 A-401

1 2 4 4.1 6 7 8 8.1 10 11 12 13
8'-6" 10'-0" 19'-81 2" 19'-81 2" 20'-6" 18'-5" 36'-8" 18'-4" 18'-11 2" 18'-11 2" 2'-0"

18'-6" 152'-111 2"


TYPICAL EAST FACING
A SUITE DIMENSIONS
A
1'-6"

1'-6"
B B
5'-1"

5'-1"
11 3'-03 4" R2 WE5 6'-0" 5'-0" 3'-10" 5'-0" 4'-1" WE5 WE5 R2
R2

C C

101 4"
1 W10 W10 W10 W10 W10 W10 W10 TYP W10 W10 W10 W10 W10 W10 W10 W10 W10 WE5
1
9'-11"

9'-11"
PW4 PW4 PW4 A-503 PW4 PW4 PW4 PW4
17'-5"

18'-53 8"
11
R2
D D
KING KING KING KING KING KING KING KING
4 11 4 SUITE SUITE SUITE SUITE SUITE SUITE SUITE SUITE
7'-6"

8'-11"
WE2 301 303 305 307 309 311 313 315 2'-03 8" 1
A-501 WE5
E WE3A A-301
1'-5"

2 F STAIR PW3
F
P9
A-301 A 10 9 WE3A

12'-101 2"
7'-7"

WE2

10'-9"
P8
PW3 PW3 PW3 2
21'-101 2"

G A-401
2 ELEVATOR PW5
ACC KING
6'-5"

A-401 P9 SUITE L F1
P5 ACC KING KING KING KING KING KING
302 2'-0 8"3
11
SUITE SUITE SUITE SUITE SUITE SUITE L
G1 SIM
304 306 308 310 312 314
WE3A
2'-75 8"
4'-9"

WE2 1
4'-9"

14'-6"
14'-55 8"
H 3'-05 8" 4 PW4 PW4 PW4 PW4 PW4 PW4
WE5
WE4 A-405 1'-95 8"
6'-6"

4 WE5 W8 W8 W9 W9 W8 W9 W8 1'-103 8" W8 W9 W9 W8 W8 W9 W9 W8


W8 4

101 4"
J J
4'-2"

4'-2"

4'-2"
10'-21 2" 8'-31 2" 5'-0" 3'-4" 5'-0" 8'-33 4" 3'-4" 5'-0" 3'-10" 5'-0" 4'-3" 5'-0" 5'-0" 4'-3" 5'-0" 5'-0" 4'-3" 5'-0" 3'-71 4"

4'-2"
7'-6"

7'-6"
1'-111 2"
WE5 4'-01 4" 6" 4'-21 8" 6" 6 4'-05 8" WE5 63 4" 4'-05 8" 63 4" WE5
K A-405
K

TYPICAL WEST FACING


8'-6"

8'-6"
R3 11 R3
SUITE DIMENSIONS

L L

3 1
2'-0" 6'-10" A-301 A-401 2'-9" 18'-11 2"

DRAWING TITLE

1 2 3 4 4.1 5 6 7 8 8.1 9 10 11 12 THIRD FLOOR PLAN


GUEST ACCOMMODATION

You might also like