Stke 1
Stke 1
GENERAL NOTES: C1
12 LIGHTS 18 LIGHTS
C2 HEAD ELECT'L
15AT 15AT SECTION
ISSUED BY:
1. ALL ELECTRICAL INSTALLATION HEREIN SHALL BE IN ACCORDANCE WITH THE C3
26 LIGHTS
30AT 30AT
15 LIGHTS
C4 THIS SITE
PROVISION OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, THE 10 CONVENIENT 10 CONVENIENT
BUILDING OFFICIAL
OUTLET OUTLET
C5 C6
EXISTING LOCAL ORDINANCES, AND THE REQUIREMENT OF THE LOCAL POWER 30AT 30AT
4 FREEZER
YA AVE.
6 CHILLER
C7 C8
40AT 40AT
2. ALL ELECTRICAL INSTALLATION HEREIN SHALL BE UNDER THE DIRECT SUPERVISION
UBALDO LA
LIFT MOTOR PUMP QUEZON
C9 C10 DEPARTMENT OF TRADE AVENUE
EXTENS THE REIDENCE BY IVORY
OF A DULY LICENSED ELECTRICAL ENGINEER. 30AT 30AT AND INDUSTRY
ION AMS CHICKEN HAUS.INC
LA FANG HOMEGROWN
PUMP ACU QUEZON AVENUE GOURMET
C12 EXTENSION
C11 QUEZON AVENUE EXTENSION
3. THE TYPE OF POWER SERVICE TO BE SUPPLIED SHALL BE 220v, SINGLEE PHASE, 30AT 30AT
2-WIRE+G, 60HZ C13
ACU ACU
C14
30AT 30AT
ACU ACU AGUINAL
4. THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF SERVICE C15 C16
.
DO EXT
RY DR
30AT 30AT
ENTRANCE FOR CONNECTION TO POWER SUPPLY. FK SUPERMARKET
A
AGUINAL
SEMIN
ACU ACU DO EXT
COMPANY. C17 C18
30AT 30AT
AGUINAL
DO EXT
COUPLES FOR
5. UNLESS OTHERWISE SPECIFIED, THE MINIMUM SIZE OF WIRE AND CONDUIT SHALL C19
SPARE OUTLET SPARE LIGHTS
C20 CHRIST PROVENSIAL
VE.
MISSIONARY CENTER
30AT 30AT
LAYA A
BE 3.5mm² AND 1/2" DIA. RESPECTIVELY. THE LOFT HOTEL ILIGAN
O
ILLIGAN CITY HALL
UBALD
BADELLE
SODA ENTERPRISES S EXT.
6. ALL MATERIALS SHALL BE NEW AND OF THE APPROVED TYPE.
DR.
2
5.0mm Ø THW GROUND WIRE
RY
PROVIDE 38''Ø X 8'-0'' COPPER BADELLE
SEMINA
CLAD STEED GROUND ROD S EXT.
7. ALL CONDUITS AND WIREWAYS AND/OR INDICATED IN THE PLANS ARE TYPICAL SINGLE LINE BADELL
ES EXT ILLIGAN CITY ANAHAW
.
DIAGRAMMATIC, EXACT LOCATION IN ROOMS, WALL PENETRATIONS SHALL BE
SCHEMATIC DIAGRAM BADELLE
S EXT.
DETERMINED BY THE ENGINEER.
SCHEDULE OF LOAD 2 STOREY COMMERCIAL BUILDING
LEGEND:
CKT NO.
DESCRIPTION NO.OF NO.OF SWITCH PHASE VOLTS CKT. SIZE OF SIZE OF CONDUIT
1 VICINITY MAP
DOWNLIGHT W/ HOUSING
(USE 18 WATTS LED BULB TRI COLOR)
OF LOAD OUTLETS LIGHTS
S1 2WS S3
WATTS LOAD AMP
BREAKER CONDUCTOR PIPE E1 SCALE NTS
18-10 WATTS,2- 18 WATTS 1.25
C1 22 SINGLE 220V 276 15 AT 2
2-2.0mm THW 15mm Ø
2 - 30WATTS
RECESSED CIRCULAR DOWNLIGHT 14-10 WATTS,3- 18 WATTS 1.01
C2 18 SINGLE 220V 224 15 AT 2
2-2.0mm THW 15mm Ø
(USE 10 WATTS LED BULB TRI COLOR) 1 - 30WATTS
18-10 WATTS,1- 18 WATTS 1.85
C3 26 SINGLE 220V 408 15 AT 2
2-2.0mm THW 15mm Ø
10 WATTS LED WALL LIGHT SURFACE 7 - 30WATTS
MOUNTED LAMP WARM LIGHT) 14-10 WATTS, 0.77
C4 15 SINGLE 220V 224 15 AT 2
2-2.0mm THW 15mm Ø
1 - 30WATTS
4 WATTS LED STRIP PER METER (WARM LIGHT) CONVENIENCE OUTLET 10 30 AT
2
2-3.5mm THW 30mm Ø
C5 (220VA/OUTLET)DUPLLEX SINGLE 220V 2200 10
CONVENIENCE OUTLET 10 30 AT
2
2-3.5mm THW 30mm Ø
4 PCS- 7 WATTS LED ADJUSTABLE TRACK C6 (220VA/OUTLET)DUPLLEX SINGLE 220V 2200 10
LIGHT ON TRACK BAR
40 AT 2-5.5mm 2 THW
2
VALIDITY SEAL PROJECT TITLE: PROJECT OWNER: DESIGNED BY: REVISIONS THIS DRAWING IS ISSUED FOR: SHEET NO:
PRC NO: 5152 10 -12-22 DRAWN BY: DATE REMARKS PERMIT PRESENTATION
CHRISTOPER M. DE LEON
PROFESSIONAL ELECTRICAL ENGINEER
PROPOSED APPROVED BY: CONSTRUCTION ADVANCE COPY E1
PTR: 4879290 01-06-25
2 STOREY COMMERCIAL BUILDING PROJECT. NO: AS-BUILT ESTIMATE
TALISAY CITY TIN: 295-218-373 LOCATION: AGUINALDO EXTENSION ,ILIGAN CITY,NORTHERN MINDANAO
ADDRESS:
DATE: BIDDING OWNER'S APPROVAL 01 3