Kidde Fire Systems Component Description: 2-Inch Discharge Valve

The Kidde Fire Systems 2-inch discharge valve is designed for high capacity discharge flow from mid-range cylinders and is FM approved, UL listed, and RoHS compliant. It requires installation in the cylinder neck ring, must be rebuilt every 15 years or after discharge, and is compatible with various Kidde fire suppression systems. Specific part numbers are provided for ordering replacement valves tailored to different fire suppression agents.

Uploaded by

frgcocloud
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
160 views3 pages

Kidde Fire Systems Component Description: 2-Inch Discharge Valve

The Kidde Fire Systems 2-inch discharge valve is designed for high capacity discharge flow from mid-range cylinders and is FM approved, UL listed, and RoHS compliant. It requires installation in the cylinder neck ring, must be rebuilt every 15 years or after discharge, and is compatible with various Kidde fire suppression systems. Specific part numbers are provided for ordering replacement valves tailored to different fire suppression agents.

Uploaded by

frgcocloud
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Kidde Fire Systems

Component Description

Effective: April 2023


2-Inch Discharge Valve K-85-9045 Rev AA

FEATURES
• Large Capacity Agent Cylinder • FM Approved
• Grooved Fitting Connection • UL Listed
• RoHS Compliant

DESCRIPTION
The Kidde Fire Systems 2-inch valve is designed to facil-
itate high capacity discharge flow from mid-range cylin-
ders. Valves manufactured after April 2014 do not include
the pressure relief device as that is located on the cylin-
der shoulder, not the valve.
OPERATION
The Kidde Fire Systems 2-inch valve can be operated by
all existing Kidde Fire Systems control heads. Actuation
of the control head displaces the valve piston, allowing
agent to flow through the discharge port of the valve.
The valve must be rebuilt with all the o-rings replaced
every 15 years or after a discharge.
INSTALLATION
The valve must be installed in the cylinder neck ring prior
to filling the cylinder. Upon assembly of the valve and
siphon tube arrangement the valve should be torqued to
100 - 110 ft-lbs (135.5 -149.1 Nm).
SPECIFICATION
Valve body: Brass
Piston: Brass
Finish: Natural
Valve seat: Rubber
Nominal operating pressure: 360 psig at 70°F
(2.48 Mpa at 21°C)
Operating temperature range: 32 to 130°F (0 to 54°C)
Weight: 46 lb. (21 kg)
Outlet: 2-inch NPT fitting

1
DIAGRAMS
PRO CAP

ACTUATION
PORT

PLUG
(PORT ON REAR)

PRIMARY CYLINDER
ADAPTER KIT
(PORT ON REAR)

USE PLUG OR
PRIMARY CYLINDE
R
ADAPTER KIT

OUTLET USE PRESSURE SWITCH


OR SAFETY CAP
PROTECTION
CAP

PRESSURE PRESSURE
INDICATOR SWITCH
SAFETY
CAP

Figure 1. 2" Valve General Arrangement

Gauging Dimension:
.515 - .565 in.
Valve Cap
 Schrader Core
Cap O-ring Œ

Spring
Piston
Assembly Ž

 Neck O-ring

Siphon Tube

Figure 2. 2 in (50 mm) Valve


Table 1: 2 in (50 mm) Valve Components

Figure 2” Valves Part


Description
Item No. Number
1 O-ring, cap Included in Rebuild Kit
2 O-ring, neck Included in Rebuild Kit
3 Piston Assembly Included in Rebuild Kit
4 Schrader core WK-220278-000
Note: This is not the re-build kit. For contents of the
rebuild kit, see datasheet K-85-0503.

2 K-85-9045

Effective: April 2023


ORDERING INFORMATION
The 2-inch valve can be purchased as a separate component to replace existing valves on all 200, 350, and 450 lb. cyl-
inders. When ordering a replacement valve, please order the correct valve for the system. Using a valve that is not
listed with the system will invalidate any agency approvals. The part number for the valve is listed in the following table:

Part Number Description

85-154000-550 2” Valve for Kidde Fire Systems ECS-500™ systems using Fluoro-K™ Fire Suppression Clean Agent

85-150000-550 2” Valve for Kidde Fire Systems ECS-500™ systems using 3M™ Novec™1230 Fire Protection Fluid

85-154000-500 2” Valve for Kidde Fire Systems ADS™ using Fluoro-K™ Fire Suppression Clean Agent

85-150000-500 2” Valve for Kidde Fire Systems ADS™ using 3M™ Novec™1230 Fire Protection Fluid

85-154000-510 2” Valve for Kidde Fire Systems ECS™ using Fluoro-K™ Fire Suppression Clean Agent

85-150000-510 2” Valve for Kidde Fire Systems ECS™ using 3M™ Novec™1230 Fire Protection Fluid

45-150000-001 2” Valve for Kidde Fire Systems ECS™ using 3M™ Novec™1230 Fire Protection Fluid with Safety Burst Disc
on the Valve
85-150000-530 2” Valve for Kidde Fire Systems ECS™ using HFC-227ea Agent
90-150000-000 2” Valve for Kidde Fire Systems ECS™ using HFC-227ea Agent with Safety Burst Disc on the Valve
85-150000-520 2” Valve for Kidde Fire Systems ADS™ using HFC-227ea Agent
85-150200-000 2” Valve Rebuild Kit

COMPATIBILITY
Series DIOM P/N Approvals

Kidde Fire Systems ECS-500™ System 06-237585-001 UL, ULC, FM

Kidde Fire Systems ECS-500™ Marine System 06-237589-001 UL, ULC, USCG

Kidde Fire Systems ADS™ for use


06-237256-001 UL, ULC, FM
with Fluoroketone Fire Suppression Agents

Kidde Fire Systems ADS™ Marine for use


06-237257-001 UL, ULC, USCG
with Fluoroketone Fire Suppression Agents

Kidde Fire Systems ADS™ with HFC-227ea Agent 06-236068-001 UL, ULC, FM

Kidde Fire Systems ADS™ Marine with HFC-227ea Agent 06-236595-001 UL, ULC, USCG

Kidde Fire Systems ECS™ 360 for use


06-236553-001 UL, ULC, FM
with Fluoroketone Fire Suppression Agents

Kidde Fire Systems ECS™ 360 Marine for use


06-236559-001 UL, ULC, USCG
with Fluoroketone Fire Suppression Agents

Kidde Fire Systems ECS™ 360 with HFC-227ea Agent 06-236115-001 UL, ULC, FM

Kidde Fire Systems ECS™ 360 Marine with HFC-227ea Agent 06-236225-001 UL, USCG

EXPORT INFORMATION (USA)


Jurisdiction: EAR
Classification: EAR99
This document contains technical data subject to the EAR.
All trademarks are the property of their respective owners.
This literature is provided for informational purposes only. KIDDE-FENWAL, INC. believes this data to be accurate, but it is published and presented without any guarantee
or warranty whatsoever. KIDDE-FENWAL, INC. assumes no responsibility for the product's suitability for a particular application. The fire suppression system design,
installation, maintenance, service and troubleshooting must be performed by trained, authorized Kidde Fire Systems distributors for the product to work correctly.
If you need more information on this product, or if you have a particular problem or question, contact:
KIDDE-FENWAL, INC., Ashland, MA 01721 USA, Telephone: (508) 881-2000.

3 Kidde Fire Systems


400 Main Street
Ashland, MA 01721
K-85-9045 Rev AA Ph: 508.881.2000
Fax: 508.881.8920
©2023 Carrier kiddefiresystems.com

You might also like