0% found this document useful (0 votes)
770 views337 pages

Praxair Catalog

The document provides an introduction to a range of high-quality products and application-based solutions offered by Praxair, including a comprehensive distribution network and technical support. It outlines various sections of the catalog, including cylinders, pure gases, mixtures, and specialized applications. Additionally, it includes safety information and technical data relevant to the products listed.

Uploaded by

bogartshitu09
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
770 views337 pages

Praxair Catalog

The document provides an introduction to a range of high-quality products and application-based solutions offered by Praxair, including a comprehensive distribution network and technical support. It outlines various sections of the catalog, including cylinders, pure gases, mixtures, and specialized applications. Additionally, it includes safety information and technical data relevant to the products listed.

Uploaded by

bogartshitu09
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 337

INTRODUCTION ORDERING INFORMATION

AND
INTRODUCTION In this section . . .
AND ORDERING
■ The highest quality products and one of
INFORMATION the Broadest Product Lines in the industry

■ Safe, accurate and precise


Application-Based Solutions

■ Praxair’s outstanding Distribution


Network to help improve efficiency and
lower costs

■ Access to our Technical Support Centers


for immediate answers to your questions

■ A Global Presence to serve your


international needs
INTRODUCTION

TABLE OF CONTENTS

SECTION A A1- A12


Introduction and Ordering Information

SECTION B
Cylinders and Containers ............B1-B8

SECTION C
Pure Gases ............................C1-C80

SECTION D
Mixtures....................................D1-D8

SECTION E
Products for Special Applications ....E1-E40
Instrumentation ........................E1-E5
Environmental ........................E6-E16
Petrochemical ......................E17-E19
Industrial Hygiene ................E20-E22
Lasers..................................E23-E25
Healthcare ..........................E26-E30
Biotechnology ......................E31-E32
Sterilization..........................E33-E34
Food ..................................E35-E37
Semiconductor ....................E38-E40

SECTION F
Gas Handling Equipment ............F1-F134
Regulators ..............................F1-F39
Flow Devices ........................F40-F58
Purifiers/Filters......................F59-F61
Gas Distribution Systems........F62-F79
Gas Generators ....................F80-F87
Cryogenic Products ..............F88-F93
Accessories ........................F94-F108
Safety Apparatus ..............F109-F118
Medical Equipment ..........F119-F134

SECTION G
Safety Information ....................G1-G6

SECTION H
Technical Data ........................H1-H24
A
1
INTRODUCTION

INDEX

A Chlorine . . . . . . . . . . . . . . . . . . . . . . . .C18 E Gases - Applications . . . . . . . . .A6-A7, E1-E40


Abbreviations & Symbols . . . . . . . . . .H19-H20 Chlorosilicons . . . . . . . . . . . . . . . . . . . . .E39 ECD - Electron Capture Detectors . . . . . . . . .E2 Biotechnology . . . . . . . . . . . . .E31-E32
Accessories . . . . . . . . . . . . . . . . . .F94-F108 CIS-2 - Butene . . . . . . . . . . . . . . . . . . . .C13 Emergency Oxygen Kit . . . . . . . . . . . . . . .E22 Industrial Hygiene . . . . . . . . . .E20-E22
Acetylene . . . . . . . . . . . . . . . . . . . . . . . .C1 Coalescing Filters . . . . . . . . . . . . . . . . . .F87 Emergency Response Instrumentation . . . . . . . . . . . . . .E1-E5
Air . . . . . . . . . . . . . . . . . . . . . . . .C2-C3 Combustion Gases . . . . . . . . . . . . . . . .E2-E5 Phone Numbers . . . . . . .Inside Back Cover Environmental . . . . . . . . . . . . . .E6-E16
Air Compressor - Scroll . . . . . . . . . . . . . . .F86 Compressor - Air . . . . . . . . . . . . . . . . . . .F86 Environmental Gases . . . . . .A6, D4-D5, E6-E16 Healthcare . . . . . . . . . . . . . . .E26-E30
Air Dryer . . . . . . . . . . . . . . . . . . . . . . . .F85 Connections . . . . . . . . . .E30, F132, H16-H18 Evaluation Programs . . . . . . . . . . . . . . . . .D3 Food . . . . . . . . . . . . . . . . . . .E35-E37
Air Generator (Praxair’s AirLabTM) . . . . . . . .F81 Controllers - Cryogenic . . . . . . . . . . . . . . .F89 EPA Methods . . . . . . . . . . . . . . . .E8-E9, E16 Lasers . . . . . . . . . . . . . . . . . .E23-E25
Aerobic Incubation Mixtures . . . . . . .E30, E32 Conversion Factors . . . . . . . . . . . . . . .H6-H11 EPA Protocols . . . . . . . . . . . . . . . .D5, E6-E16 Petrochemical . . . . . . . . . . . . .E17-E19
AL-800 (High Frequency Cryogenic Gases EPR - Electronic Paramagnetic Semiconductor . . . . . . . . . . . .E38-E40
Discharge Detectors) . . . . . . . . . . . . . .E2 Argon . . . . . . . . . . . . . . . . . . . . .C74 Resonance . . . . . . . . . . . . . . . . . . . . .E3 Sterilization . . . . . . . . . . . . . .E33-E34
Ambient Monitoring . . . . . . . . . . . .A6, E6-E16 Carbon Dioxide . . . . . . . . . .C75, E32 Equipment and Accessories . . . . . . . . .F1-F134 Gauges . . . . . . . . . . . . . . . . . . . . . . . . .F97
Ammonia . . . . . . . . . . . . . . . . . . . . . . . .C4 Helium . . . . . . . . . . . . . . . . . . . .C76 Etchant Gases . . . . . . . . . . . . . . . . . .E38-E40 Gauges - Medical . . . . . . . . . . . . . . . . .F133
Anaerobic Incubation Mixtures . . . . . .E30, E32 Nitrogen . . . . . . . . . . . . . . .C77, E32 Ethane . . . . . . . . . . . . . . . . . . . . . . . . .C25 GC/MS (Mass Spec.) . . . . . . . . . . . . . . . .E2
Analytical Instrumentation . . . . . . . . . . . .E1-E5 Oxygen . . . . . . . . . . . . . . . . . . . .C78 Ethyl Chlorine . . . . . . . . . . . . . . . . . . . .C26 Geiger-Muller . . . . . . . . . . . . . . . . . . . . . .E5
Analytical Range Sensitivity . . . . . . . . . .E2-E5 Cryogenic Products Ethylene . . . . . . . . . . . . . . . . . . . . . . . .C27 Glossary . . . . . . . . . . . . . . . . . . . . .H21-H24
APIMS - Atmospheric Pressure Accessories . . . . . . . . . . . . . . . . . .F93 Ethylene Oxide . . . . . . . . . . . . . . . . . . . .C28
Ionization Mass Spectrometer . . . . . . . .E4 Containers . . . . . . . . . .B6-B7, F88-F93 Ethylene Oxide Mixtures . . . . . . . . . . .E33-E34
Applications - Gases . . . . . . . . .A6-A7, E1-E40 Control Rate Freezers . . . . . . . . . . .F89 Extendapak® Gases . . . . . . . . . . .A6, E35-E37 H
Arc or Spark Emission . . . . . . . . . . . . . .E4-E5 Controllers . . . . . . . . . . . . . . . . . .F89 Halocarbon-14
Argon (gas) . . . . . . . . . . . . . . . . . . . .C5-C6 Dewars . . . . . . . . . . . . . . . . .F91-F93 (Tetrafluoromethane) . . . . . . . . . . . . .C29
Argon (liquid) . . . . . . . . . . . . . . . . . . . .C74 Refrigerators . . . . . . . . . .F88, F90-F92 F Halocarbon-22
Arsine . . . . . . . . . . . . . . . . . . . . . . . . . .C7 CYLINDERS AND (Chlorodifluoromethane) . . . . . . . . . .C30
FID - Flame Ionization Detectors . . . . . . .E2, E5
Atomic Absorption (AA) . . . . . . . . . . . . . . .E3 CONTAINERS . . . . . . . . . . . . . . .B1-B8 Halocarbon-23
Filters . . . . . . . . . . . . . . . . . . . . . .F61, F87
Atomic Emission . . . . . . . . . . . . . . . . . . . .E4 Cylinder Specifications (Trifluoromethane) . . . . . . . . . . . . . . .C31
Flammability Range . . . . . . . . . . . . .H14-H15
Atmospheric/Purge Gases . . . . . . . . .E38-E40 Ultra High Pressure . . . . . . . . . . . . .B1 Halocarbon-116
Flash Arrestors . . . . . . . . . . . . . . . . . . .F102
High Pressure - large capacity . . . . . .B1 (Hexafluoroethane) . . . . . . . . . . . . . .C32
Floor Savers . . . . . . . . . . . . . . . . . . . . .F108
High Pressure - small capacity . . . . . .B2 Halocarbon-134A
Flowmeters
B High Pressure - aluminum . . . . . . . . .B3 (1, 1, 1, 2 - Tetrafluoroethane) . . . . . .C33
Volumetric/Controller . . . . . . . .F40-F46
Low Pressure - steel . . . . . . . . . . . . .B4 Halocarbon-218
Banana Gas . . . . . . . . . . . . . . . . . . . . . .E37 Mass Flow/Controller . . . . . . . .F47-F50
Drums & SS cylinders . . . . . . . . . . . .B5 (Octafluoropropane) . . . . . . . . . . . . .C34
Benchmark Standards . . . . . . . . . .D5, E6-E16 Readout Power Supply . . . . . . . . . .F51
Liquid Helium Containers . . . . . . . . .B6 Headspace Analyser . . . . . . . . . . . . . . .F106
Biological Incubation Atmospheres . . .E30, E32 Laminar Flow/Controller . . . . . .F52-F53
Cryogenic Containers . . . . . . . . . . .B7 Healthcare Gases . . . . . . . . . . . .A7, E26-E30
Biotechnology . . . . . . . . . . . . . . .A6, E31-E32 Medical . . . . . . . . . . . . . .F125, F128
Portables . . . . . . . . . . . . . . . . . . . .B8 Heliox . . . . . . . . . . . . . . . . . . . . . . . . .E29
Blending Systems . . . . . . . . . . . . . . . . . . .D3 Flow Devices . . . . . . . . . . . . . . . . . .F40-F58
Commonly Used for Mixtures . . . . . .D2 Helium (gas) . . . . . . . . . . . . . . . . . .C35-C36
Blood Gas Analysis . . . . . . . . . . . . . . . . .E30 Fluorescence UV . . . . . . . . . . . . . . . . . . . .E4
Sampling . . . . . . . . . . . . . . . .F94-F95 Helium (liquid) . . . . . . . . . . . . . . . . . . . .C76
Boron Trichloride . . . . . . . . . . . . . . . . . . .C8 Fluorescence X (XRF) . . . . . . . . . . . . . . .E4-E5
Cylinders and Containers Safety HID - Helium Ionization Detector . . . . . . . . .E2
Boron Trifluoride . . . . . . . . . . . . . . . . . . . .C9 Food Gases . . . . . . . . . . . . . . . .A6, E35-E37
Guidelines . . . . . . . . . . . . . . . .G1-G5 High Frequency Discharge
Butadiene - 1,3 . . . . . . . . . . . . . . . . . . .C10 FPD - Flame Photometric Detectors . . . . . . . .E2
Cylinder Handling Equipment . . . . .F117-F118 Detector (AL-800) . . . . . . . . . . . . . . . .E2
Butane, Normal . . . . . . . . . . . . . . . . . . .C11 FTIR - Fourier Transform Infrared . . . . . . . . . .E3
Cylinder Preparation . . . . . . . . . . . . . . . . .D3 Hydrogen . . . . . . . . . . . . . . . . . . . .C37-C38
Butene - 1 . . . . . . . . . . . . . . . . . . . . . . .C12 Fuel-Oxidizer Mixtures . . . . . . . . . . . . . . . .D4
Cylinder Management . . . . . . . . . . . . . . . .A7 Hydrogen Bromide . . . . . . . . . . . . . . . . .C39
Butene - CIS-2 . . . . . . . . . . . . . . . . . . . .C13
Cylinder Scales . . . . . . . . . . . . . . .F107-F108 Hydrogen Chloride . . . . . . . . . . . . . . . . .C40
Butene - Trans-2 . . . . . . . . . . . . . . . . . . .C14
Cylinder Securing . . . . . . . . . . . . .F117-F118 Hydrogen Fluoride . . . . . . . . . . . . . . . . .C41
Cylinder Storage . . . . . . . . . . . . . . . . .G2-G4 G
Hydrogen Sulfide . . . . . . . . . . . . . . . . . .C42
Cylinder Wrenches . . . . . . . . . . . . . . . .F101 Gas Analyzer/Transmitter . . . . . . . .F110-F111
C Hydrogen Generator
Gas Blender . . . . . . . . . . . . . . . . . . .F55-F56
(Praxair’s HyLabTM) . . . . . . . . . . . . . .F80
Cabinets - Gas . . . . . . . . . . . . . . . . . . . .F77 Gas Cabinets . . . . . . . . . . . . . . . . . . . . .F77
Hydrometer . . . . . . . . . . . . . . . . . . . . . . .E5
Calibration Unit - Portable . . . . . . . . . . . . .F54 Gas Chromatography . . . . . . . . . . . . . .E1-E2
D
Calibration Gas Cylinder . . . . . . . . . . . . .E22 Gas Compatibility . . . . . . . . . . . . . . . .H1-H5
Delivery Systems . . . . . . . . . . . . . . . . .A8-A9
Carbon Dioxide (gas) . . . . . . . . . . . .C15-C16 Gas Detection Controller . . . . . . . . . . . . .F109
Deuterium . . . . . . . . . . . . . . . . . . . . . . .C19 I
Carbon Dioxide (liquid) . . . . . . . . . .C74, E32 Gas Dilution System . . . . . . . . . . . . . .F57-F58
Dew Point . . . . . . . . . . . . . . . . . . . . . . . .H9
Carbon Monoxide . . . . . . . . . . . . . . . . .C17 Gas Distribution Panels . . . . . . . . . . . . . . .F78 IFG/GFC (Correlation) . . . . . . . . . . . . . . . .E3
Diagnostic Gases . . . . . . . . . . . . . . .E-29-E30
Carbon and Sulfur in Steel . . . . . . . . . . . . .E5 Gas Distribution Systems . . . . . . . . . . .F62-F78 ICP - Inductive Coupled Plasma . . . . . . . . . .E4
Diborane . . . . . . . . . . . . . . . . . . . . . . . .C20
Carboxide® . . . . . . . . . . . . . .E33-E34, H1-H2 Gas Generators I/M Standards . . . . . . . . . . . . . . . . . . . .E13
Dichlorosilane . . . . . . . . . . . . . . . . . . . .C21
Carrier Gases . . . . . . . . . . . . . . . . . . .E2-E5 Hydrogen (HyLabTM) . . . . . . . . . . . .F80 Industrial Hygiene . . . . . . . . . . . . . . .E20-E22
DID - Discharge Ionization Detector . . . . . . .E2
Certificates . . . . . . . . . . . . . . . . . . . . . . .D3 Nitrogen (NitroLabTM) . . . . . . . .F82-F83 Instrumentation Gases . . . . . . . . . . . . . .E1-E5
Dimethyl Ether . . . . . . . . . . . . . . . . . . . .C22
Certified Standards .D5, E6-E16, E29-E30, E32 Zero Air (AirLabTM) . . . . . . . . . . . .F81 International Production Facilities . . . . . . . .A11
Dimethylamine . . . . . . . . . . . . . . . . . . . .C23
CGA Connections . . . . . . . . . . . . . . . . . . . . . Gas Generator Back-Up System . . . . . . . . .F84 INTRODUCTION AND
Dispersive Infrared (IR) . . . . . . . . . . . . . . . .E2
Pure Gases . . . . . . . . . . . . . .H16-H18 Gas Grade Recommendations . . . . . . . . .E2-E5 ORDERING INFORMATION . . .A1-A12
Disilane . . . . . . . . . . . . . . . . . . . . . . . .C24
Gas Mixtures . . . . . . . . . . . .D10, F105 GAS HANDLING EQUIPMENT . . . .F1-F134 IR - Dispersive Infrared . . . . . . . . . . . . . . . .E3
Distribution Systems . . . . . . . . . . . . . . .A8-A9
Medical Mixtures . . . . .E30, F129-F130 Gas Heaters . . . . . . . . . . . . . . . . . . . . .F101 Isobutane . . . . . . . . . . . . . . . . . . . . . . .C43
DI Water System . . . . . . . . . . . . . . . . . . .F86
Check Valves . . . . . . . . . . . . . . . . . . . .F101 Gas Purifiers . . . . . . . . . . . . . . . . . . .F59-F61 Isobutylene . . . . . . . . . . . . . . . . . . . . . .C44
Documentation . . . . . . . . . . . . . . . . . . . . .D3
Chemical/Petrochemical Gases . . .A6, E17-E19
Dopant Gases . . . . . . . . . . . . . . . . .E38-E40
Chemical Formulas . . . . . . . . . . . . . .H14-H15
Dynamic Blends . . . . . . . . . . . . . .D5, E6-E16
Chemiluminescence . . . . . . . . . . . . . . . . . .E4

A
2
INTRODUCTION

INDEX

K N Q Transducer . . . . . . . . . . . . . . . . . . . . . . .F99
Krypton . . . . . . . . . . . . . . . . . . . . . . . . .C45 Natural Gas . . . . . . . . . . . . . . . . . . . . .C50 Quality Assurance / Control . . . .D3, E29, E31 Trichlorosilane . . . . . . . . . . . . . . . . . . . .C70
Natural Gas Standards . . . . . . . . . . . . . .E18 Quench Gas . . . . . . . . . . . . . . . . . . . . . .E5 Trimethylamine . . . . . . . . . . . . . . . . . . . .C71
NDIR - Non Dispersive Infrared . . . . . . . . . .E3 Tungsten Hexafluoride . . . . . . . . . . . . . . .C72
L Neon . . . . . . . . . . . . . . . . . . . . . . . . .C51
Laboratory Gases . . . . . . . . . . . . . .A7, E1-E5 Nitric Oxide . . . . . . . . . . . . . . . . . . . . .C52 R
Laser Gases . . . . . . . . . . . . . . . . . . .E23-E25 Nitrogen (gas) . . . . . . . . . . . . . . . . .C53-C55 Reactant Gases . . . . . . . . . . . . . . . .E-38-E40 U
Leak Detection & Testing . . . . . . . . .F112-F116 Nitrogen (liquid) . . . . . . . . . . . . . . .C77, E32 Reactive Gas Mixtures . . . . . . . . .D4, E20-E21 Universities . . . . . . . . . . . . . . . . . .A7, E1-E5
Lung Diffusion Mixtures . . . . . . . . . . . . . . .E29 Nitrogen Dioxide . . . . . . . . . . . . . . . . . .C56 Reference Materials . . . . . . . . . . . . . . . . . .D3 UltraSpec 2000TM
Nitrogen Generator Refillable Cylinders . . . . . . . . . . . . . .B8, E22 Trace Analyzer . . . . . . . . . . . . . . .F79
(Praxair’s NitroLabTM) . . . . . . . . . .F82-F83 Refrigerators - Cryogenic . . . . . . .F88, F90-F92 USD - Ultrasonic Detector . . . . . . . . . . . . . .E2
Nitrogen Trifluoride . . . . . . . . . . . . . . . . .C57 Regulators - Index . . . . . . . . . . . . . . . . . . .F2
M
Nitrous Oxide . . . . . . . . . . . . . . . . . . . .C58 Critical Purity . . . . . . . . . . . . . .F5-F10
Manifolds
NIST Traceable Reference High Purity . . . . . . . . . . . . . . .F11-F16
Critical Purity . . . . . . . . . . . . . . . .F74 V
Materials . . . . . . . . . . . . . . . .D5, E6-E16 High Purity Economical . . . . . . .F17-F19
Fully Automatic (Medical) . . . . . . .F126 Valves
NMR - Nuclear Magnetic Resonance . . . . . .E3 General Purpose . . . . . . . . . . . . . .F20
Semi-Automatic (Medical) . . . . . . .F127 Diaphragm . . . . . . . . . . . . . . . . . .F96
Non-Certified Standards . . . . . . . . . . . .D5, D7 Special Purpose . . . . . . . . . . . .F21-F36
Mass Spectrometry . . . . . . . . . . . . . . .E1, E4 Needle Valve . . . . . . . . . . . . . . . .F96
Non-Reactive Gas Mixtures . . . . . . . . . . . .E21 Digital . . . . . . . . . . . . . . . . . .F37-F38
Master Grades . . . . . . . . . . . . . . . . . .D4-D5 Silcosteel® Treated . . . . . . . . . . . . .F95
Non-Refillable Cylinders . . . . . . . . . . .E20-E21 Medical . . . . . . . . . . . . . . .F119-F125
Material Safety Data Sheet Vapor Pressure . . . . . . . . . . . . . . . . . . . . .D4
North American Production Facilities . . . . .A10 Regulator Station . . . . . . . . . . . . . . . . . . .F65
(MSDS) . . . . . . . . . . . . . . . . . . . . . .G1 VersiGasTM Lab System . . . . . . . . . . . .F62-F64
Nuclear Counter . . . . . . . . . . . . . . . . . . . .E5 Research Gas Materials (RGMs) . . . . . .E6-E16
Materials Compatibility . . . . . . . . . . . . .H1-H5 VOC Standards . . . . . . . . . . . . . . . . . . .E16
Medical Gases/Mixtures .A7, E26-E30, E33-E34 Rotameters . . . . . . . . . . . . . . . . . . . .F40-F45 Volume of Ideal Gas . . . . . . . . . . . . . . . .H10
Pure . . . . . . . . . . . . . . . . . . .E26-E28
Cryogenic Gases . . . . . . . . . .C75-C78 O
Mixtures . . . . . . . . . . . . . . . .E29-E30 Optical Spectrometry . . . . . . . . . . . .E1, E3-E4 S X
Laser . . . . . . . . . . . . . . . . . . .E23-E25 Oxygen (gas) . . . . . . . . . . . . . . . . .C59-C60 Safety Apparatus . . . . . . . . . . . . . .F109-F118 Xenon . . . . . . . . . . . . . . . . . . . . . . . . .C73
Sterilization . . . . . . . . . . . . . .E33-E34 Oxygen (liquid) . . . . . . . . . . . . . . . . . . .C78 SAFETY INFORMATION . . . . . . . . . .G1-G6 XeScan® Contrast Enhancement
Medical Equipment . . . . . . . . . . . .F119-F134 Oxyfume® 20, 2000, 2002 . . . . . . . .E33-E34 Sampling Canisters, Cylinders Agent . . . . . . . . . . . . . . . . . . . . .E29
Gas Regulators . . . . . . . . . .F119-F122 and Valves . . . . . . . . . . . . . . .F94-F95 XRF - Fluorescence X . . . . . . . . . . . . . . .E4-E5
Mixture Regulators . . . . . . . .F123-F124 Semiconductor Process Gases . . . .A7, E38-E40
Section Regulators . . . . . . . . . . . .F125 P SFC/SFE Start-Up Kit . . . . . . . . . . . . . . . .F69
Flowmeters . . . . . . . . . . . .F125, F128 Paramagnetic Analyzer . . . . . . . . . . . . . . .E5 Silane . . . . . . . . . . . . . . . . . . . . . .C64-C65
Z
Manifolds . . . . . . . . . . . . . .F126-F127 PAS - Photoacoustic . . . . . . . . . . . . . . . . . .E3 SilcoCanTM Canisters . . . . . . . . . . . . . . . .F94
Zero Air Generator
CGA Connections . . . . . . . .F129-F130 Personal Protective Equipment . .G1, F109-F116 Silcosteel® Treatment . . . . . . .F75-F76, F94-F95
(Praxair’s AirLabTM) . . . . . . . . . . . . . .F81
Pigtails . . . . . . . . . . . . . . . . . . . .F131 Petrochemical Gases . . . . . . . . . .A6, E17-E19 Silicon Precursor Gases . . . . . . . . . . .E38-E40
Zero Gases . . . . . . . . .E2-E5, E6-E16, E20-E22
Connections . . . . . . . . . . . . . . . .F132 Pharmaceutical . . . . . . . . . . . . . .A7, E31-E33 Silicon Tetrachloride . . . . . . . . . . . . . . . .C66
Gauges . . . . . . . . . . . . . . . . . . .F133 Phosphine . . . . . . . . . . . . . . . . . . . . . . .C61 Silicon Tetrafluoride . . . . . . . . . . . . . . . . .C67
Hoses . . . . . . . . . . . . . . . . . . . .F134 Physical Constants . . . . . . . . . . . . . . . . .H10 Spark Emission . . . . . . . . . . . . . . . . . . .E4-E5
Medifume® . . . . . . . . . . . . . . . . . . .E33-E34 Physical Properties of Gases . . . . . . .H11-H15 Specialty Gases Calibration
Membrane Air Dryer . . . . . . . . . . . . . . . .F85 PID - Photo Ionization Detector . . . . . . . . . . .E2 Products . . . . . . . . . . . . .E1-E5, E6-E16
Methane . . . . . . . . . . . . . . . . . . . . . . . .C46 Pigtails . . . . . . . . . . . . . . . . . . . . . . . .F100 Specialty Gases Delivery Systems . . . . . . . .A8
Methyl Bromide . . . . . . . . . . . . . . . . . . .C47 Pigtails (Medical) . . . . . . . . . . . . . . . . . .F131 Standard Grades . . . . . . . . . . . . . . . . .D4-D5
Methyl Chloride . . . . . . . . . . . . . . . . . . .C48 Pipe Thread Fittings . . . . . . . . . . . .F103-F104 Stationary Source Emissions
Micro Blend . . . . . . . . . . . . . . . . . . . .E6-E16 Pressure Switch . . . . . . . . . . . . . . . . . . . .F98 Monitoring . . . . . . . . . . . . . . . . . . .E6
MIXTURES . . . . . . . . . . . . . . . . . . . .D1-D8 Primary Master . . . . . . . . . . . . . . .D5, E6-E16 Sterilant Gases & Mixtures . . . . . . . . .E33-E34
Mixture Grades and Primary Standards . . . . . . . . . . . . .D5, E6-E16 Suction Regulators . . . . . . . . . . . . . . . . .F125
Specifications . . . . . . . .D4-D5, E7, E13 Process Enhancement Products . . . . . . . . . . .E6 Sulfur Dioxide . . . . . . . . . . . . . . . . . . . .C68
Mixture Components . . . . . . . . . . . . . .D7-D10 PRODUCTS FOR SPECIAL Sulfur Hexafluoride . . . . . . . . . . . . . . . . .C69
Mixture - Custom . . . . . . . . . . . . . . . . . . .D6 APPLICATIONS . . . . . . . . . . . . .E1-E40 Supercritical Fluids . . . . . . .C15-C16, E7, E15
Mixture Homogenization . . . . . . . . . . . . . .D3 Propane . . . . . . . . . . . . . . . . . . . . . . . .C62 Switchover Systems
Mixtures - Medical . . . . . . . . . . . . . . .E29-E30 Proportional Counter . . . . . . . . . . . . . . . . .E5 Electronic Liquid . . . . . . . . . . . . . .F67
Mixtures - Laser . . . . . . . . . . . . . . . . .E23-E25 Proportioners & Mixers . . . . . . . . . . . . . . .F44 Electronic Liquid Level Gauge . . . . . .F68
Mixture Safety and Quality . . . . . . . . . . . . .D4 Propylene . . . . . . . . . . . . . . . . . . . . . . .C63 Economical Liquid . . . . . . . . . . . . .F69
Mixtures - Special Applications . . . . . . .E1-E40 Protocol Station . . . . . . . . . . . . . . . . . . . .F66 Automatic . . . . . . . . . . . . . . . .F70-F73
Mixture Selection Guide . . . . . . . . . . . .D1-D2 PURE GASES . . . . . . . . . . . . . . . . .C1-C80
Mobile Sources . . . . . . . . . . . . . . . . . .E6-E16 Pure Organic Products . . . . . . . . . . . . . . .E17
Molecular Sieves . . . . . . . . . . . . . . . . . . .F60 Purifiers . . . . . . . . . . . . . . . . . . . . . .F59-F61 T
Monomethylamine . . . . . . . . . . . . . . . . .C49 Purge Assemblies . . . . . . . . . . . . . . . . . . .F39 TECHNICAL DATA . . . . . . . . . . . . . .H1-H24
MS (Under Vacuum) . . . . . . . . . . . . . . . . . .E4 TCD - Thermal Conductivity
Detectors . . . . . . . . . . . . . . . . . . .E2, E5
Terms and Conditions . . . . . . . . . . . . . .A4-A5
Therapy Gases . . . . . . . . . . . . . .A7, E26-E29
Threshold Limit Values (TLV) . . . . . . . .H14-H15
Trans-2 - Butene . . . . . . . . . . . . . . . . . . .C14

A
3
INTRODUCTION

TERMS AND CONDITIONS

Terms and Conditions NOT LIMITED TO WARRANTY OF 5. Contingencies. Neither Seller


“Seller” offers to sell the products set MERCHANTABILITY AND WARRANTY nor Purchaser will be liable to the other
forth in this catalog subject to the fol- OF FITNESS FOR A PARTICULAR PUR- party for default or delay in the per-
lowing terms and conditions: POSE. formance of any of its obligations in
connection with the purchase, sale,
1. Prices and Terms of 3. WARNING! SELLER WARNS PUR- shipment or delivery of the products,
CHASER THAT THERE ARE HAZARDS due to Act of God, accident, fire, flood,
Payment. Gas prices are F.O.B. our
ASSOCIATED WITH THE USE OF THE riot, war, sabotage, explosion, strike,
plants. All freight, storage, handling,
GAS PRODUCTS LISTED IN THIS CATA- labor disturbance, national defense
insurance and other charges relating to
LOG. SELLER DIRECTS PURCHASER’S requirement, governmental law, ordi-
shipment F.O.B. our plant or delivery
ATTENTION TO THE HAZARDS LISTED nance, rule or regulation, whether valid
will be for the account of Purchaser.
IN THIS CATALOG WITH RESPECT TO or invalid, inability to obtain electricity
Purchaser will pay the amount of any
EACH PURE GAS PRODUCT (AND or other type of energy, raw material,
sales, use of excise taxes imposed by
WHICH ALSO APPLY TO MIXTURES OF labor, equipment , or transportation, or
reason of sale or delivery. Terms of
THAT GAS). IT IS INCUMBENT UPON any similar or different contingency
payment will be net cash thirty (30)
PURCHASER TO WARN ITS PERSON- beyond their reasonable control which
days following date of invoice.
NEL OF THE HAZARDS ASSOCIATED would make performance commercially
WITH THE PRODUCTS. PURCHASER impracticable whether or not the contin-
ALSO ASSUMES ALL RESPONSIBILITY gency is of the same class as those enu-
2. Warranty
FOR THE SUITABILITY AND THE merated, it being expressly agreed that
Seller warrants that the products will
RESULTS OF USING PRODUCT ALONE such enumeration shall be nonexclusive.
meet the specifications listed in this cat-
OR IN COMBINATION WITH OTHER
alog, will be adequately contained,
ARTICLES OR SUBSTANCES AND IN 6. Entire Agreement. Seller’s
packaged and labeled and conform to
ANY MANUFACTURING, MEDICAL entire offer and agreement is contained
any promises and affirmations of fact
OR OTHER PROCESS OR PROCEDURE. in these terms and conditions and this
made on the container and label, and ,
SELLER WILL NOT BE LIABLE FOR ANY catalog. Any other or different terms
in the case of equipment, will be free
INCIDENTAL OR CONSEQUENTIAL and conditions in any purchase order
from defects in material and workman-
DAMAGES ARISING FROM NON- issued or accepted for the products
ship. Upon confirmation, Seller shall
WILLFUL FAILURE TO DELIVER PROD- shall be deemed null and void.
replace any product which does not so
UCT HEREUNDER.
conform, provided that such product, or
an adequate representative sample, is
4. Cylinders. Some gas products
returned to Seller, with transportation
will be shipped or delivered by Seller
charges prepaid and a Seller’s return
in returnable cylinders, and there may
authorization tag firmly affixed. No
be a charge for the use of such cylin-
claim of any kind against Seller with
ders. Purchaser will return all return-
respect to the products, whether or not
able cylinders to Seller in a non-con-
based on negligence or warranty, shall
taminated condition with valves tightly
be greater than the purchase price of
closed and sufficient residual pressure
the product in respect to which such
to prevent contamination. All return-
claim is made. THERE ARE NO
able cylinders will remain the property
EXPRESS WARRANTIES BY SELLER
of Seller at all times. Purchaser will
(OTHER THAN THOSE SPECIFIED IN
pay Seller for any damage, beyond
THIS PARAGRAPH 2). NO WAR-
wear and tear, to returnable cylinders
RANTIES BY SELLER (OTHER THAN
while in the possession of Purchaser.
WARRANTY OF TITLE AS PROVIDED
*Gas products shipped or delivered by
IN THE UNIFORM COMMERCIAL
Seller in lecture bottles (LB) include the
CODE) SHALL BE IMPLIED OR OTHER-
cost of the container and are nonreturn-
WISE CREATED UNDER THE UNIFORM
able.
A COMMERCIAL CODE INCLUDING BUT

4
INTRODUCTION

PRAXAIR FAX

Ordering via Praxair FAX is E-A-S-Y


when you complete this form!

Date:

Praxair FAXOrder Form Praxair Order Location: Seattle


Praxair Phone: 2 0 6 - 6 2 4 -
Praxair Fax: 206-682-6802
Name the PRAXAIR
location receiving
your order.

Company Name: A B C Company Customer Account No: A1000


Ship To: 123 Successful Avenue Purchase Order Number: 9 8 7 6 5
Unit #7 Fort Knox, WA Bill To (if different from Ship To Address):
To make sure your (123) 456-7890 Same as Ship To Indicate name and
order arrives at the Phone: address of bill to
correct location, Fax:
( 1 2 3 ) 4 5 6 - 7 89 1 location here.
please complete the Dr. Beakman
Ordered By:
ship to information
accurately. Be sure Special Instructions:
to include special Delivery Instructions: Please ship Regulator via UPS
instructions if you x Praxair Delivery Truck
❑ ❑ Transport
require them. x Courier (if any required)
❑ ❑ Other
Specify your pre-
ferred delivery
Order Information method.
Qty Part No. Cyl. Style Product Description Grade Remarks
(if gas (for gas orders)
order)

2 NI 5.0UH T T Nitrogen UHP Page C-

3 K 1200 ppm Carbon Dioxide Certified


1.0 % Oxygen standard
Balance Nitrogen

1 L S HECDNI T T 4.5% Carbon Dioxide Laser Certificate


of
13.5% Nitrogen Certified Analysis

1 CON 412 3-3-3-1-580


Critical Purity- Non-corrosive Regulator
Dual Stage Series 412

Use this space for


PRAXAIR ORDER NO.______________________________________________________________ additional comments
TIPS AND REMINDERS: you may have about
Pure Gases: To complete product code, add desired cylinder style as last character; Use Remarks section to record catalog page number of product. your order.
Gas Mixtures: List minor components from lowest to highest concentration; use “Remarks” column for any special requests. Refrain from using Chemical
Symbols, use full gas name. To ensure order accuracy place zeros in front of decimal points for concentrations. (eg. 0.25% vs. .25%)
Equipment: Use Remarks section to record catalog page number of product.

Remember to follow
these tips when ordering
Pure Gas, Gas Mixtures
and Equipment via
Praxair FAX.
A
5
INTRODUCTION

THE MARKETS WE SERVE

BIOTECHNOLOGY CHEMICAL/PETROCHEMICAL ENVIRONMENTAL FOOD

With many years of experience Beginning in the early 1970's


supplying the largest chemical and and accelerating through the
As a leading supplier of specialty petrochemical companies in the 1980's and 1990's, environ- Praxair offers gases for freezing,
gases to the biotechnology mar- industry, we have the flexibility to mental testing has grown to chilling, carbonation and preser-
ket, Praxair has developed a full meet your unique requirements. become a large and diverse vation. After extensive shelf life
line of products for use in this Praxair offers: market. With our complete prod- testing, gas mixtures are devel-
exciting, fast paced industry. Pure Gases: From small cylinders uct line, Praxair satisfies the oped to increase the shelf life of
Pure medical and biological to bulk, we have a ready supply of need for continuous emission some foods. Praxair has a fully
atmosphere gases are produced a variety of containers including 6 monitoring (CEM), mobile emis- equipped food lab to conduct
to U.S. Pharmacopoeia (U.S.P.) and 12-packs of cylinders, tube sion monitoring and ambient testing and make recommenda-
specifications. trailers and small bulk systems. monitoring. tions for controlled atmosphere
Praxair also offers a full line of spe- packaging (CAP) and modified
Hydrocarbon and Sulfur Blends: For example, utilities have strict
cialty equipment commonly used atmosphere packaging (MAP).
High quality gas mixtures for instru- requirements for emissions con-
by biotechnology companies: Praxair’s Extendapak® gases are
ment calibration and process con- trol compliance. As a result,
available to help you add value
■ Refrigerators, Freezers trol are critical in this industry. proper certification and record-
to your food products.
■ Gas Distribution Systems Praxair has a full line of gaseous keeping are critical. As the
and liquid hydrocarbon blends to source for all of your stack emis- Please refer to the Products for
■ Cryogenic Transfer Hoses
satisfy your requirements for stan- sion gas requirements, we fill Special Applications (section E -
■ Sample Storage Dewars
dard and custom mixtures. These mixtures that are certified and pages E35-E37) of this catalog
■ Personal Safety Equipment
mixtures are made from the highest in compliance with the United for in-depth information on
quality source materials for which States Environmental Protection Praxair products for the food
Please refer to section E industry.
all minor hydrocarbon components Agency (EPA) Protocol require-
(Products for Special
have been detected and quantified. ments.
Applications), pages E31-E32,
for in-depth information on Piston (constant pressure) cylinders Please refer to pages E6-E16
Praxair biotechnology products. are provided upon request. As with (section E - Products for Special
all mixtures, certificates of analysis Applications) for in-depth infor-
are available. mation on Praxair environmental
Please refer to pages E17-E19 ( products.
section E - Products for Special
Applications) for in-depth informa-
tion on Praxair petrochemical prod-
ucts.

A
6
INTRODUCTION

THE MARKETS WE SERVE

Cylinder Management
Due to the volume of gas cylinders used in these indus-
tries, Praxair has developed a cylinder management
program with the flexibility required to help customers
lower costs and meet anticipated supply needs. The
available options include a Just-In-Time (JIT) deliv-
ery system and an On-site Management program.
For more information on how this program can be
tailored to meet your needs, please contact your
Praxair representative.
LABORATORIES/
HEALTHCARE RESEARCH/UNIVERSITIES PHARMACEUTICAL SEMICONDUCTOR

Improved productivity, reduced


costs and environmental compli-
ance are three key concerns for Praxair is a world leader in the
the pharmaceutical industry. supply of semiconductor process
For many years, Praxair has The wide variety of applications Praxair has proven, cost effec- gases for the electronics indus-
served the diverse needs of for specialty gases in these mar- tive products and services to try. We offer a full product line
healthcare by supplying many kets makes Praxair an excellent meet your needs. including silicon source materi-
departments including respirato- choice. Our full product line, als, dopants, etchants, and bulk
Pure gases: From small cylin-
ry therapy, central supply, sur- wide variety of containers and products. The continuous drive
ders to bulk, we have a ready
gery and clinical laboratories. excellent distribution network to increase device performance
supply of large containers in-
Our line of medical, specialty meets the needs of busy re- means that specialty gases and
cluding 6, 12 and16-packs of
gases and services includes: search scientists and laboratory chemicals must reach higher
cylinders, tube trailers and small
technicians. Our experience with purity levels; containers and
■ Therapy Gases bulk systems. In addition, we
major universities and research equipment must be free from
(Medical Drug Gases) offer:
laboratories throughout North contamination and analyses
■ Diagnostic Gases
America provides insight into the ■ Full Specialty Equipment must be precise.
(Medical Device Gases) Product Line
specific needs of these markets: For more details, please refer
■ Pulmonary Functions Mixtures ■ Certified Medical Gases
(Lung Diffusion) ■ Carrier Gases to the section E - Products for
■ Research Grade Gases
■ Anaerobic and Aerobic Mixtures ■ Calibration Gases Special Applications, pages
■ Calibration Gases E38-E40, or call 1-800-PRAXAIR
■ Laser Gases ■ Technical Support
■ Technical Support and request the Praxair’s
■ CT Scanning Mixtures ■ Specialty Equipment
■ Cylinder Management Semiconductor Gases, Equipment
■ Sterilant Gases ■ Cylinder Management
and Services catalog (P-8176).
■ Instrument Gases
■ Cylinder Management For details, please refer to
Services section E (Products for Special
■ Technical Support Applications), pages E1-E5.

Please refer to the Products for


Special Applications section
(pages E26-E30) of this catalog
for in-depth information on
Praxair healthcare products.

A
7
INTRODUCTION

SPECIALTY GASES DELIVERY SYSTEMS

Praxair specialty gases are delivered through


a distribution network that is simply the best
in North America!

As a world class leader, customers can rely


on Praxair for:

■ A quick, reliable supply of specialty gases.


■ Cost-effective and efficient distribution.
■ The most flexible delivery system avail-
able...designed to meet customer require-
ments throughout North America.
■ Liquid
■ Packaged
■ On-site
■ Membranes

Here’s what Praxair Specialty Gases and


Equipment delivers: Praxair’s delivery systems helps minimize
your needs for cylinder storage, handling
■ Excellent supply capabilities throughout and administrative paperwork.
North America with more than 600
distribution locations.
■ Direct distribution via Praxair trucks in most
markets.
■ Distribution through a network of select
distributors in some markets.
■ Quick product delivery and empty cylinder
pick-up.
■ Couriers and common carriers when
required to meet customer needs.
■ Just-In-Time (JIT) delivery services for
customers who need it.

A
8
INTRODUCTION

GAS HANDLING EQUIPMENT DELIVERY SYSTEMS

Praxair’s gas handling solutions are design-


ed to help you preserve the purity of your
mixture and ensure the correct gas flow and
delivery pressure. As an industry leader, cus-
tomers can rely on Praxair for:

■ Excellent supply capabilities throughout


North America with strategic stocking
locations and state-of-the-art warehousing
and distribution logistics.
■ An inventory available through local
stocking locations at key production sites
throughout North America.
■ Drop ship services direct from key
manufacturers when required.
■ Couriers and common carriers for quick,
efficient, local service.

In addition, Praxair also offers Just-In-Time


(JIT) delivery services from our major
warehouse locations.

A
9
INTRODUCTION

NORTH AMERICAN SPECIALTY GASES MAJOR PRODUCTION FACILITIES

CANADA UNITED STATES FLORIDA OHIO


City : Orlando, FL City: North Royalton, OH
ALBERTA ARIZONA
Phone: (407) 851-4711 Phone: (440) 237-8770
City: Edmonton Alberta City : Phoenix, AZ
Fax: (407) 851-2157 Fax: (440) 582-2143
Phone: (780) 449-7185 Phone: (602) 272-2151
Fax: (780) 449-5302 Fax: (602) 278-8607 PENNSYLVANIA
ILLINOIS
City: Bethlehem, PA
BRITISH COLUMBIA City: Hillside, IL
City : Kingman, AZ Phone: (800) 772-4059
City: Vancouver BC Phone: (708) 449-9300
Phone: (602) 272-2151 Fax: (610) 758-8382
Phone: (604) 527-0700 Fax: (708) 449-0345
Fax: (602) 278-8607
Fax: (604) 540-1275 PUERTO RICO
City: Gurabo, P.R.
ONTARIO CALIFORNIA LOUISIANA
Phone: (787) 258-7200
City: Paris, Ontario City : Los Angeles, CA City: Geismar, LA
Fax: (787) 258-7233
Phone: (519) 442-1540 Phone: (888) 953-9953 Phone: (888) 495-4356
Fax: (519) 442-1666 Fax: (888) 935-3399 Fax: (504) 673-3531 TEXAS
City: Austin, TX
City: San Carlos, CA MISSOURI
Phone: (800) 269-2897
Phone: (800) 660-2066 City: St. Louis, MO
MEXICO Fax: (877) 385-6632
Fax: (800) 660-2099 Phone: (800) 429-5427
City: Monterrey N.L.
Fax: (800) 469-1329
Phone: 52-8-329-4900 City: South San Francisco, CA
Fax: 52-8-329-4949 Phone: (800) 660-2066
Fax: (800) 660-2099
City: Mexico City Edo.de Mexico
Phone: 52-5-899-3005 City: Torrance, CA
Fax: 52-5-527-9595 Phone: (888) 953-9953 Call
Fax: (888) 935-3399 1-877-PRAXAIR
and your call will be
routed to the appropriate
customer service
center.
A
10
INTRODUCTION

INTERNATIONAL SPECIALITY GASES MAJOR PRODUCTION FACILITIES

Thirty Six Specialty Gases Production Facilities...with Operations in Over Forty Countries Worldwide.
North America South America Europe Middle East
United States Argentina Austria Israel
Canada Bolivia Belgium Turkey
Mexico Brazil Bulgaria
Puerto Rico Chile Croatia Asia
Colombia Czech Republic
India
Central America Paraguay France
Indonesia
Peru Germany
Belize Japan
Uruguay Hungary
Costa Rica People’s Republic
Venezuela Italy
of China
Netherlands
Singapore
Poland
South Korea
Portugal
Thailand
Slovakia
Taiwan
Slovenia
Spain
Australia
Switzerland
United Kingdom Australia

North America/Central America South America Europe/Middle East Asia/Australia


Worldwide Headquarters White Martins Gases Praxair España Praxair Asia, Inc.
Praxair Specialty Gases & Equipment Industriais Calle Orense, 11 541 Orchard Road
39 Old Ridgebury Road Rua Mayrink Veiga, 9 28020 Madrid #20-00-Liat Towers
Danbury, CT 06810-5113 Rio de Janeiro, RJ 20090-050 Spain Singapore 238881
USA Brazil Tel: 34 (91) 556-1100 Tel: (65) 736-3800
Tel: 1-877-PRAXAIR (772-9247) Tel: 55 (21) 588-6032 Fax: 34 (91) 555-4307 Fax: (65) 736-4143
(716) 879-4077 Fax: 55 (21) 588-6683
Fax: 1-800-772-9985
(716) 879-2040
Internet: www.praxair.com/specialtygases
E-mail: specialtygases@praxair.com
A
11
INTRODUCTION

GET TO KNOW PRAXAIR SPECIALTY GASES AND EQUIPMENT

Get to know
Praxair Specialty
Gases & Equipment
Comprehensive, High
Quality Product Line
A full range of certified gases,
mixtures, gas handling equip-
ment and related services.

Application-Based
Solutions
Sales, production and research
capabilities and the ability to
supply end use customers,
OEMs and research institutes
with a safe, accurate and pre-
cise product worldwide.

Reliable Production and


Distribution Network
Seventeen specialty gases labo-
ratories and production centers,
more than 600 distribution
locations in North America and
Praxair’s own delivery fleet —
all serving you with the gases
you need when you need them.

Outstanding Technical
Support
A highly trained team of field
sales representatives, technical
service personnel and produc-
tion chemists, in concert with
dedicated market specialists
who quickly provide the guid-
ance and support our prospects
and customers need to resolve
regulatory, technical and safety
application issues.

Worldwide Coverage
Application-based research and
development at five internation-
al technical centers, combined
with specialty gases production
and distribution in over 40
countries.

A
12
CYLINDERS CONTAINERS
B

AND
CYLINDERS In this section . . .
■ Cylinder packages for all sizes, ■ Bulk tanks, tube trailers, 6, 12
AND purity and applications and 16 cylinder packs

CONTAINERS ■ New packaging innovations like the ■ Rigorous maintenance programs


Praxair portable series
■ Regulatory labeling compliance

PRAXAIR AGA AIRGAS AIR LIQUIDE AIR PRODUCTS BOC MATHESON MG SCOTT
Ultra High-Pressure Steel
6K 485 3HP 44HH BX 500 1U 3HP -
4K - - - - - - - -
3K - - 44H - - - - -

High-Pressure Steel - Large Capacity


TO - - - Y - - - -
T/UT 049 300 49 A 300.T 1L 300 K
K/UK 044 200 44 B 200.K 1A 200 A
S - - - - - - - -
SS - - - - -
M - - - - - - -

High-Pressure Steel - Small Capacity


Q / UQ 016 80 16 C 80.Q 2 80 B
ME 005 MED E MED E E E ER
G / UG 007 35 7 D-1 30.3 3 35 C
MD - - - - - - - -
F - - 3 - - - 10 -
EB/LB/RB L.B.R. L.B. LBX/LB LB 2.2/L.B. 7/LB LX/LB LB
L4 - - - - - - - -
C - - - - - - - -

High-Pressure Aluminum
AT - - - - - - - -
AS A31 150A 30(AL) B(AL) 152.1S 1R 150AL AL
AQ A16 80A 22(AL) C(AL) 82.1S 2R 80AL BL
AG A07 30A 7(AL) D-1(AL) 32.1S 3R 30AL CL
A3 - - - - - - - -

Low-Pressure Steel
FT - - - T - 1T - -
HT - - - A-5 - - - -
FS - - 125 - - - - -
FA - - - AA - - 150 XG
CL - - 57 A - 1V - XM
FC - 65 55 A-3 410 1J 65 XP
A8 110 380 70 A(C2H2) 5.WN 1B 380 XF
PX - - - - - - - -
FX 350 110 A-1 425 1F 350 XL -
FE - - C - - - - -
CYLINDERS AND CONTAINERS

COMPRESSED GAS CYLINDERS

ULTRA HIGH-PRESSURE STEEL HIGH-PRESSURE STEEL—LARGER CAPACITY

K
T
Part No. Code

/U
4K

3K
6K

T0

SS
T/

S
Transport
Canada 3AAM(182) 3AM(153) 3AAM(153)
Specs

DOT Specs 3AA-6000 E9421-4500 3AA-3600 3AA-2400 3AA-2400 3A-2015 3A-2015 3AA-2015

Internal
Volume
ft3 1.500 1.610 1.540 15.900 1.730 1.540 0.970 0.950
L 42.48 45.59 43.61 450.24 48.99 43.61 27.47 26.90

Water
Capacity
lb 93.65 100.51 96.14 992.64 108.00 96.14 60.56 59.31
kg 42.48 45.59 43.61 450.25 48.99 43.61 27.47 26.90

Nominal
Dimensions
Dia. (in) 10.00 9.25 10.00 24.00 9.25 9.00 7.50 7.37
Dia. (cm) 25.40 23.50 25.40 60.96 23.50 22.86 19.05 18.72
Ht. (in) 51.00 51.00 51.00 84.00 55.00 51.00 49.00 46.00
Ht. (cm) 129.54 129.54 129.54 213.36 139.70 129.54 124.46 116.84

Average
Tare Weight
lb 303 145 189 1200 143 133 110 76
kg 137.44 65.77 85.73 544.31 64.86 60.33 49.90 34.47

ULTRA HIGH-PRESSURE STEEL HIGH-PRESSURE STEEL—LARGER CAPACITY

SS S
TO
B
1
CYLINDERS AND CONTAINERS

COMPRESSED GAS CYLINDERS

HIGH-PRESSURE STEEL—SMALLER CAPACITY

B
/U
Part No. Code

/U

/R
E

D
M

L4
Q

M
G

EB

C
Transport
Canada 3AAM(153)
3AAM(153) 3AAM(153) 3AAM(153) 3AAM(153)
Specs

DOT Specs 3AA-2015 3AA-2015 3AA-2015 3AA-2015 3AA-2015 3E-1800 3AA-2015 3AA-1800

Internal
Volume
ft3 0.520 0.170 0.250 0.100 0.102 0.015 0.075 0.032
L 14.72 4.81 7.08 2.83 2.89 0.42 2.12 0.91

Water
Capacity
lb 32.46 10.61 15.61 6.24 6.37 0.94 4.68 2.00
kg 14.73 4.81 7.08 2.83 2.89 0.42 2.12 0.91

Nominal
Dimensions
Dia. (in) 7.00 4.00 6.00 4.04 4.25 2.00 4.18 3.50
Dia. (cm) 17.78 10.16 15.24 10.26 10.80 5.08 10.62 8.89
Ht. (in) 31.00 25.75 20.00 16.75 17.00 16.00 14.00 8.00
Ht. (cm) 78.74 65.40 50.80 42.55 43.18 40.64 35.56 20.32

Average
Tare Weight
lb 65 13 29 9 10 4 9 4
kg 29.48 5.90 13.15 4.08 4.54 1.81 4.08 1.81

B
2
CYLINDERS AND CONTAINERS

COMPRESSED GAS CYLINDERS

HIGH-PRESSURE ALUMINUM

Part No. Code

3
Q
S
T

A
A
A

A
Transport
Canada TC3ALM(153) TC3ALM(139) TC3ALM(153) TC3ALM(153) TC3ALM(153)
Specs

DOT Specs 3AL-2216 3AL-2015 3AL-2216 3AL-2216 3AL-2216

Internal
Volume
ft3 1.700 1.040 0.550 0.140 0.210
L 48.14 29.45 15.57 3.96 5.95

Water
Capacity
lb 106.13 64.93 34.34 8.74 13.00
kg 4814 29.45 15.57 3.96 5.90

Nominal
Dimensions
Dia. (in) 10.00 8.00 7.25 5.00 6.90
Dia. (cm) 25.40 20.32 18.42 12.70 17.50
Ht. (in) 54.00 48.00 33.00 17.00 16.00
Ht. (cm) 137.16 121.92 83.82 43.18 40.64

Average
Tare Weight
lb 90 48 30 9 14.8
kg 40.82 21.77 13.64 4.08 6.70

B
3
CYLINDERS AND CONTAINERS

COMPRESSED GAS CYLINDERS

LOW-PRESSURE STEEL

Part No. Code

A8
HT

FA
FS

CL

FX
FT

PX

FE
FC
DOT Specs 110A500W 4BW-240 3A-480 4AA-480 3A-480 4BA-300 8AL 4BW-300 4BA-240 4BA-240

Internal
Volume
ft3 26.900 16.050 4.460 4.460 1.930 1.970 3.830 3.830 0.370
L 761.72 454.49 126.29 126.29 54.65 55.78 108.45 108.45 10.48

Water
Capacity
lb 1679.37 1002.00 278.44 278.44 120.49 122.99 239.11 239.11 23.10
kg 761.75 454.50 126.30 126.30 54.65 55.79 108.46 108.46 10.48

Nominal
Dimensions
Dia. (in) 30.00 29.75 15.00 15.00 10.00 10.00 12.00 15.00 15.00 9.00
Dia. (cm) 76.20 75.57 38.10 38.10 25.40 25.40 30.48 38.10 38.10 22.86
Ht. (in) 82.00 55.00 54.00 52.00 48.00 47.00 45.00 45.00 45.00 18.00
Ht. (cm) 208.28 139.70 137.16 132.08 121.92 119.38 114.30 114.30 114.30 45.72

Average
Tare Weight
lb 1115 315 200 151 85 55 180 85 75 20
kg 505.76 142.88 90.72 68.49 38.56 24.95 81.65 38.56 34.02 9.07

B
4
CYLINDERS AND CONTAINERS

COMPRESSED GAS CYLINDERS

LOW-PRESSURE DRUMS, LOW-PRESSURE STAINLESS STEEL DRUMS AND CYLINDERS

30
55

10
Part No. Code

M
SA

SB

ST
D
ST

ST
DOT Specs E-4884-240 E-4884-240 UN-1A1 P-5 UN-1A1 UN-1A1

Internal
Volume
ft3 1.450 1.450 7.350 8.420 4.010 1.340
L 41.06 41.06 208.13 238.43 113.55 37.94

Water
Capacity
lb 90.52 90.52 458.86 525.66 250.34 83.66
kg 41.06 41.06 208.14 238.44 113.55 37.95

Nominal
Dimensions
Dia. (in) 9.00 9.00 24.00 27.00 18.00 12.00
Dia. (cm) 22.86 22.86 60.96 68.58 45.72 30.48
Ht. (in) 44.00 44.00 46.00 45.00 44.00 30.00
Ht. (cm) 111.76 111.76 116.84 114.3 111.76 76.20

Average
Tare Weight
lb 290 150 50
36 36 250
kg 16.33 18.14 113.40 131.54 68.04 22.68

B
5
CYLINDERS AND CONTAINERS

LIQUID HELIUM CONTAINERS

HIGH PERFORMANCE LIQUID HELIUM DEWARS

Our dewars make it easier for


you to handle liquid helium;
they have several features devel-
oped and patented by Praxair
for this special purpose.
■ Multi-layer insulation to
reduce evaporation losses.
■ Cooled shields to simplify
your operation thereby reduc-
ing costs and hazards.
Escaping helium vapor is
used to cool the system,
avoiding the need for cooling
with nitrogen with its atten-
dant cost and hazardous CMSH-60 CMSH-100 CMSH-250 CMSH-500
vapors in an enclosed area. Capacity (L) (max) 60 100 250 500
■ Light weight for easier lifting Diameter (in) 24 24 32 42
and moving.
Height w/Casters (in) 51 60 70 73
■ Rugged, all-welded construction
Weight – Empty (lb) 191 210 340 562
for increased performance life
of the multi-layer insulation and Neck Diameter (in) 1 1/2 1 1/2 2 1/4 2 1/4
shiled system. Static Loss (max. per day) 2% 11/4 % 1% /4%
3

■ Large-diameter neck tubes


available to allow for better
structural integrity and for
larger-sized liquid helium
withdrawal apparatus.
■ Non-magnetic dewars avail-
able for use with Magnetic
Resonance Imaging (MRI)
units.
■ Absolute relief valve to extend
use of dewars to airborne as
well as surface shipments.
■ Complete Society of
Automotive Engineers (SAE)
range of dewars available to
meet all known liquid helium
volume needs.

B
6
CYLINDERS AND CONTAINERS

CRYOGENIC CONTAINERS

CRYOGENIC CONTAINERS

ID

L
L

A
U
A

U
Q

U
U

D
LI
D

L—

L—
L—

L—
Part No. Code

L
0-

0
0

0
20

26

23
18

16
DOT Specs 4L412 4L200 4L200 4L200 4L200

Internal
Volume
ft3 7.210 6.770 6.210 9.740 8.470
L 204.16 191.71 175.85 275.81 239.84

Water
Capacity
lb 469.20 422.65 387.69 608.07 528.78
kg 212.83 191.71 175.85 275.82 239.85
Nominal
Dimensions
Dia. (in) 20.00 20.00 20.00 26.00 26.00
Dia. (cm) 50.80 50.80 50.80 66.04 66.04
Ht. (in) 65.80 64.00 60.00 58.00 53.00
Ht. (cm) 167.13 162.56 152.40 147.32 134.62
Average
Tare Weight
lb 375 260 250 320 300
kg 170.10 117.93 113.40 145.15 136.08

CRYOGENIC CONTAINERS

B
7
CYLINDERS AND CONTAINERS

PORTABLES

Praxair's portable cylinders are Portable Cylinders—Refillable Portable Cylinders—Non-Refillable

designed to offer maximum conven-


ience for the rigors of the industrial
environment. The new refillable
cylinder reduces the need for dispos- Part No. Code

3
P

5
1

8
TC

2
TE

D
D

D
D
ables and that's both good for the
environment and the bottom line. Transport
Canada TC 39M
Specs

DOT Specs 3AL-2015 3AL-2015 DOT-39 TC 39M DOT-39 DOT-39 DOT-39 DOT-39 DOT-39 DOT-39 E-8990

Internal
Volume
ft3 0.160 0.060 0.130 E-8990 0.084 0.450 0.057 0.061 0.035 0.052 0.035
L 4.53 1.70 3.68 0.130 2.38 12.74 1.61 1.73 0.99 1.47 0.99

Water
Capacity
lb 9.99 3.75 8.12 3.68 5.23 28.09 3.56 3.81 2.19 3.25 2.19
kg 4.53 1.70 3.68 8.12 2.37 12.74 1.61 1.73 0.99 1.47 0.99

Nominal
Dimensions
Dia. (in) 4.40 4.40 4.25 3.68 4.25 9.00 3.30 3.50 3.00 4.00 4.25
11.18 11.18 10.80 4.25 10.80 22.86 8.38 8.89 7.62 10.16 10.80
Dia. (cm)
32.60 17.84 25.00 10.80 13.00 16.50 13.75 13.60 10.60 9.75 7.75
Ht. (in)
82.80 45.31 63.50 20.63 33.02 41.91 34.93 34.54 26.92 24.77 19.69
Ht. (cm)

Average
Tare Weight
lb 10.5 6.32 12 52.40 8 7 2.51 1.32 0.96 5 5
kg 4.76 2.87 5.44 12 3.63 3.18 1.14 0.60 0.44 2.27 2.27

For an even better handle on


Praxair’s portable cylinders con-
tact your representative.

■ Lightweight aluminum cylinder


(6.3 pounds)
■ High impact resistant cover
■ Cost effective, all-in-one design.
(Flow control, Yoke and Post Valve,
Regulator)
■ Convenient and precision click-stop
contoured flow knob
■ Guaranteed, certified gas grades
■ Back pack available for hands-free
portability

B
8
PURE GASES
C
PURE In this section . . .
GASES
■ More than 65 Pure Gases to meet
your needs

■ The right grades developed for the


right applications

■ Cylinder information for each


Pure Gas

■ Transport information for each


■ Pure product quality assay shown
Pure Gas
is a guaranteed minimum purity
specification. For each product
grade, “less than values” for typical
■ Regulator recommendations for
impurities are provided. Upon each Pure Gas
request, additional impurity
identification, analysis or certification ■ A broad selection of bulk products
can be provided. including bulk liquid and gaseous
tube trailer
■ Should you desire, other cylinder
styles are available.

■ Please make sure you review our


instrumentation gases section
beginning on page E1.
There you will find Praxair’s
recommendations for the optimum
pure gas specification for each type
of instrument.
PURE GASES

ACETYLENE

TRANSPORTINFORMATION: FORMULA: C2H2


UN No. 1001
MSDS REFERENCE: 4559
CAS NO.: 74 -- 86 -- 2
Acetylene, Acetylene Acetylene, GENERAL DESCRIPTION:

Shipping Name: Dissolved Dissolved Colorless, highly flammable gas.

Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information

REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 ( SECTION F, PAGE 2)

AC 2.6AA 2.6 99.6 % A8 360 / 10.19 202 SERIES


ATOMIC O2 + CH4 < 4000 ppm
ABSORPTION* PH3 < 20 ppm

*Specially purified and prepared for use in all atomic absorption spectrophotometers.

CAUTION: Do not discharge acetylene at pressures exceeding 15 psig/104 kPa, gauge, therefore use Regulator 202-5651.

Cylinder style availability varies by location.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
Praxair, your full line supplier for specialty
STYLE / CGA psig / kPa, gauge lb / kg gases and equipment.
A8 / 510 250 / 1724 207 / 94

C
1
PURE GASES

AIR
TRANSPORTINFORMATION: FORMULA: N/A
UN No. 1002
MSDS REFERENCE: 4560
CAS NO.: 132259-10-0
GENERAL DESCRIPTION:

Shipping Name: Air, Compressed Air, compressed Air, Compressed Colorless, odorless, nonflammable gas.

Hazard Class: 2.2 2.2 2.2

Nonflammable Nonflammable Nonflammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 ( SECTION F, PAGE 2)

AI 0.0UM ULTRA ZERO O2 19.9% - 21.9% AS 144 / 3.99 400 SERIES : Non-corrosive
AMBIENT H2O < 2 ppm AQ 83 / 2.30
MONITORING CO2 - 315 - 385 ppm* A3 31 / 0.86
CO < 0.05 ppm T 310 / 8.60
THC < 0.05 ppm K 232 / 6.43
NOX < 0.02 ppm Q 78 / 2.16
*Available without CO2 upon request.

AI 0.0VC VOLATILE O2 20.9% ± 1% abs AS 144 / 3.99 400 SERIES : Non-corrosive


ORGANIC H2O < 2 ppm AQ 83 / 2.30
COMPOUND CO2 < 0.3 ppm A3 31 / 0.86
FREE CO < 0.05 ppm
THC < 0.01 ppm
VOC*

*Individually analyzed for customer selected VOC component(s).

AI 0.0CE CONTINUOUS O2 20.9% ± 1% abs AS 144 / 3.99 400 SERIES : Non-corrosive


EMISSION H2O < 2 ppm AQ 83 / 2.30
MONITORING CO2 < 0.3 ppm A3 31 / 0.86
ZERO CO < 0.05 ppm
THC < 0.05 ppm
NOX < 0.01ppm
SO2 < 0.01 ppm

AI 0.0VE VEHICLE O2 19.9% - 21.9% T 310 / 8.60 400 SERIES : Non-corrosive


EMISSION H2O < 2 ppm AS 144 / 3.99 300 SERIES : Non-corrosive
ZERO* CO2 < 1 ppm** AQ 83 / 2.30
CO < 1 ppm
THC < 1 ppm

*Complies with Title 40 CFR86. 114-79 and EPA I/M 240.


For BAR applications, please see page E14.
For alternative applications, other specifications may apply.
**Available with 315-385 ppm CO2 on request.

C
2
PURE GASES

AIR

Product and Package Information

REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

AI 0.0HC HYDROCARBON O2 19.5% - 23.5% T 310 / 8.60 300 SERIES : Non-corrosive


FREE H2O < 3 ppm K 232 / 6.43 200 SERIES : Non-corrosive
THC < 0.1 ppm Q 78 / 2.16
CO2 < 0.1 ppm F 15 / 0.42
CO < 0.1 ppm

CO/CO2 analysis provided upon request.

AI 0.0Z ZERO O2 19.9% - 21.9% T 310 / 8.60 300 SERIES : Non-corrosive


THC < 0.5 ppm K 232 / 6.43 200 SERIES : Non-corrosive

AI 0.0XD EXTRA DRY O2 19.5% - 23.5% 6K 504 / 13.98 492 SERIES : Special Purpose
H2O < 10 ppm 4K 442 / 12.26 492 SERIES : Special Purpose
T 310 / 8.60 300 SERIES : Non-corrosive
K 232 / 6.43 200 SERIES : Non-corrosive

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
See Section E - Industrial Hygiene for Air-Zero
STYLE / CGA psig / kPa, gauge lb / kg in Praxair portable cylinder.
6K / 702 6000 / 41369 347 / 158
4K / 347 4500 / 31027 181 / 82 Praxair application specific zero gases are
AS / 590 2000 / 13790 62 / 28 certified to meet your performance criteria. We
AQ / 590 2200 / 15168 47 / 21 analyze the relevant impurities to meet
A3 / 590 2200 / 15168 20 / 9 applicable EPA method requirements.
T/ 590 2640 / 18202 165 / 76
K/ 590 2200 / 15168 150 / 68 See Section E - Medical Gases for Medical Air -
Q/ 590 2200 / 15168 71 / 32
U.S.P. Grade
F/ 590 2200 / 15168 16 / 7

Praxair, your global supplier.


C
3
PURE GASES

AMMONIA

TRANSPORTINFORMATION: FORMULA: NH3


UN No. 1005
MSDS REFERENCE: 4562
CAS NO.: 7664 -- 41 -- 7
Ammonia, Ammonia, Ammonia, GENERAL DESCRIPTION:
Anhydrous anhydrous, Anhydrous
liquified Colorless, toxic, corrosive, liquified gas with a
Shipping Name:
sharp, intensely irritating odor.
Hazard Class: 2.2 2.4 (9.2) 2.2
Nonflammable Corrosive Nonflammable
Label: Gas Gas Gas

Product and Package Information

REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

AM 5.0RS 5.0 99.999 % AS 30 lb / 13.6 kg 400 SERIES : Corrosive


RESEARCH O2 < 0.5 ppm 408 SERIES : Special Purpose
H2O < 1 ppm
CO2 < 0.4 ppm
CO < 0.1 ppm
THC < 0.1 ppm
N2 < 1.5 ppm

AM 4.0 4.0 99.99% FA 150 lb / 68.0 kg 400 SERIES : Corrosive


(liquid phase) K 50 lb / 22.7 kg 408 SERIES : Special Purpose

AM 5.5SP 5.5 99.9995 % AS 30 lb / 13.6 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 0.5 ppm 400 SERIES : Corrosive
PROCESS H2O < 3 ppm 408 SERIES : Special Purpose
GAS CO < 0.1 ppm
CH4 < 0.5 ppm
N2 < 1 ppm

AM 5.0SP 5.0 99.999 % K 50 lb / 22.7 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 2 ppm AS 30 lb / 13.6 kg 400 SERIES : Corrosive
PROCESS H2O < 3 ppm 408 SERIES : Special Purpose
GAS CO < 1 ppm
CH4 < 1 ppm
N2 < 3 ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT See our extensive line of safety products in
STYLE / CGA psig / kPa, gauge lb / kg Section F.
FA / 240 / 705 114 / 786 300 / 136
K / 240 / 660 / 720 114 / 786 183 / 83
AS / 660 / 720 114 / 786 80 / 36

C
4
PURE GASES

ARGON

TRANSPORTINFORMATION: FORMULA: Ar
UN No. 1006
MSDS REFERENCE: 4563
CAS NO.: 7440 -- 37 -- 1
Argon, Argon, Argon, GENERAL DESCRIPTION:

Shipping Name: Compressed compressed Compressed Colorless, odorless, nonflammable inert gas.

Hazard Class: 2.2 2.2 2.2

Nonflammable Nonflammable Nonflammable


Label: Gas Gas Gas

Product and Package Information

REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 ( SECTION F, PAGE 2)

AR 6.0RS 6.0 99.9999 % T 335 / 9.29 400 SERIES : Non-corrosive


RESEARCH H2O < 1 ppm K 248 / 6.88
N2 < 1 ppm F 100L
O2 < 0.2 ppm RB 50L
THC < 0.1 ppm

AR 5.5TG 5.5 99.9999 % T 335 / 9.29 400 SERIES : Non-corrosive


TRACE CO < 0.1 ppm AT 272 / 7.54 300 SERIES : Non-corrosive
ANALYTICAL CO2 < 0.1 ppm K 248 / 6.88
H2 < 1 ppm
H2O < 0.5 ppm
N2 < 2 ppm
O2 < 0.5 ppm
THC < 0.5 ppm

AR 5.0UH 5.0 99.999 % T 335 / 9.29 400 SERIES : Non-corrosive


ULTRA H2O < 3 ppm K 248 / 6.88 300 SERIES : Non-corrosive
HIGH N2 < 4 ppm Q 83 / 2.30
PURITY O2 < 1 ppm
THC < 0.5 ppm

AR 4.8IC 4.8 99.999 % T 335 / 9.29 300 SERIES : Non-corrosive


INDUCTIVELY O2 < 3 ppm K 248 / 6.88 200 SERIES : Non-corrosive
COUPLED H2O < 2 ppm
PLASMA CO2 < 1 ppm
THC < 1 ppm
N2 < 10 ppm
H2 < 1 ppm

AR 4.8 4.8* 99.998 % 6K 575 / 15.94 492 SERIES : Special Purpose


O2 < 5 ppm 4K 495 / 13.23 492 SERIES : Special Purpose
H2O < 3 ppm 3K 385 / 10.68 492 SERIES : Special Purpose
T 335 / 9.29 300 SERIES : Non-corrosive
*Suitable for surgical applications. K 248 / 6.88 200 SERIES : Non-corrosive

AR 4.8Z 4.8 99.998 % T 335 / 9.29 300 SERIES : Non-corrosive


ZERO THC < 0.5 ppm K 248 / 6.88 200 SERIES : Non-corrosive
Q 83 / 2.30

C
5
PURE GASES

ARGON

Product and Package Information

REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

AR 4.8OF 4.8 99.998 % T 335 / 9.29 300 SERIES : Non-corrosive


O2 FREE O2 < 0.5 ppm K 248 / 6.88 200 SERIES : Non-corrosive
Q 83 / 2.30

AR 6.0SP 6.0 99.9999 % SS 155 / 4.30 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 0.2 ppm AS 153 / 4.24 400 SERIES : Non-Corrosive
PROCESS H2O < 0.2 ppm AT 272 / 7.54
GAS CO2 < 0.1 ppm
CO < 0.1 ppm
THC < 0.1ppm
N 2 < 0.5 ppm
H2 < 0.1 ppm

AR 5.5SP 5.5 99.9995 % AT 272 / 7.54 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 0.5 ppm 400 SERIES : Non-Corrosive
PROCESS H2O < 0.5 ppm
GAS CO2 < 0.5 ppm
CO < 0.5 ppm
THC < 0.5ppm
N 2 < 2 ppm
H2 < 0.5 ppm

AR 5.0SP 5.0 99.999 % K 248 / 6.88 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 2 ppm AS 153 / 4.24 400 SERIES : Non-corrosive
PROCESS H2O < 3 ppm 300 SERIES : Non-Corrosive
GAS CO2 < 1 ppm
CO < 1 ppm
THC < 1ppm
N 2 < 6 ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
Product available in larger quantities, 6, 12
STYLE / CGA psig / kPa, gauge lb / kg and 16 pack cylinder clusters, dewars, tube
AT / 580 / 718 2200 / 15168 120 / 54 trailers and bulk.
AS / 580 / 718 2000 / 13790 66 / 30
SS / 580 / 718 2000 / 13790 126 / 57 See Pg C74 for cryogenic liquid argon.
6K / 677 6000 / 41368 362 / 164
4K / 680 4500 / 31026 198 / 90 Praxair’s extensive distribution network
3K / 680 3500 / 24131 228 / 103
ensures on-time delivery.
T/ 580 2640 / 18202 177 / 80
K/ 580 2200 / 15168 158 / 72
Q/ 580 2200 / 15168 74 / 34
F/ 580 474 / 3199 16 / 7
RB / 580 1775 / 12238 5 / 3
C
6
PURE GASES

ARSINE

TRANSPORTINFORMATION: FORMULA: AsH3


UN No. 2188
MSDS REFERENCE: 4565
CAS NO.: 7784 -- 42 -- 1
GENERAL DESCRIPTION:

Shipping Name: Arsine Arsine Arsine Colorless, highly toxic, flammable gas with a
garlic-like odor.
Hazard Class: 2.3 2.3 (2.1) 2.3

Toxic Gas, Toxic Gas, Toxic Gas,


Label: Flammable Gas Flammable Flammable Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

AS 6.0SP 6.0 99.9999 % SS 5.0 lb / 2.27 kg 700 SERIES : Semiconductor


SEMICONDUCTOR Ar + O2 < 0.2 ppm 400 SERIES : Corrosive
PROCESS H2O < 0.1 ppm
GAS N2 < 0.1 ppm
THC < 0.05 ppm
CO2 < 0.05 ppm
CO < 0.05 ppm
CH4 < 0.05 ppm
PH3 < 0.05 ppm
SiH4 < 0.1 ppm

AS 5.7SP 5.7 99.9997 % SS 5.0 lb / 2.27 kg 700 SERIES : Semiconductor


SEMICONDUCTOR Ar + O2 < 0.5 ppm 400 SERIES : Corrosive
PROCESS H2O < 1 ppm
GAS N2 < 1 ppm
THC < 0.05 ppm
CO2 < 0.05 ppm
CO < 0.05 ppm
CH4 < 0.05 ppm
PH3 < 0.05 ppm

Contact your local Praxair representative for additional packages and content.

AS 5.2SP 5.2 99.9992 % L4 0.5 lb / 0.23 kg 700 SERIES : Semiconductor


SEMICONDUCTOR Ar + O2 < 1 ppm EB 0.2 lb / 0.09 kg 400 SERIES : Corrosive
PROCESS H2O < 1 ppm
GAS N2 < 1 ppm
THC < 1 ppm
CO2 < 1 ppm
CO < 1 ppm
CH4 < 1 ppm
PH3 < 1 ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT Use the convenient Praxair Fax to place
STYLE / CGA psig / kPa, gauge lb / kg orders for your specialty gases and
SS / 350 /632 205 / 1413 117 / 53 equipment.
L4 / 350 /632 205 / 1413 12 / 5
EB / 350 205 / 1413 5/3

C
7
PURE GASES

BORON TRICHLORIDE
TRANSPORTINFORMATION: FORMULA: BCl3
UN No. 1741
MSDS REFERENCE: 4566
CAS NO.: 10294 -- 34 -- 5
GENERAL DESCRIPTION:
Colorless, toxic, corrosive, nonflammable,
Shipping Name: Boron Trichloride Boron Trichloride Boron Trichloride liquified gas with a pungent, choking odor.

Hazard Class: 2.3 2.3 (8) 2.3

Toxic Gas, Toxic Gas, Toxic Gas,


Label: Corrosive Corrosive Corrosive

Product and Package Information

REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

BC 5.0 5.0 99.999% K 100 lb / 45.36 kg 455 SERIES : Special Purpose


Cl2 < 3 ppmw G 14 lb / 6.35 kg
COCl2 < 3 ppmw
Si < 1 ppmw
N 2 < 4 ppm
O2 < 1 ppm

BC 3.0 3.0 99.9 % K 100 lb / 45.36 kg 455 SERIES : Special Purpose


CI2 < 100 ppmw G 14 lb / 6.35 kg
COCl2 < 900 ppmw
Si < 10 ppmw

BC 3.6SP 3.6 99.96 % K 100 lb / 45.36 kg 700 SERIES : Semiconductor


SEMICONDUCTOR Cl2 < 100 ppmw G 14 lb / 6.35 kg 455 SERIES : Special Purpose
PROCESS COCl2 < 300 ppmw
GAS Si < 10 ppmw

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
See our full line of safety equipment and gas
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg cabinets in Section F.
K / 660 / 634 4.4 / 30.3 223 / 101
G / 660 / 634 4.4 / 30.3 43 / 20

C
8
PURE GASES

BORON TRIFLUORIDE
TRANSPORTINFORMATION: FORMULA:
BF3
UN No. 1008
MSDS REFERENCE: 4567
CAS NO.: 7637 -- 07 -- 2
Boron Trifluoride, Boron Trifluoride Boron Trifluoride, GENERAL DESCRIPTION:

Shipping Name: Compressed Compressed Colorless, toxic, corrosive, nonflammable gas


with a pungent odor.
Hazard Class: 2.3 2.3 2.3

Label: Toxic Gas Toxic Gas Toxic Gas

Product and Package Information

REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 ( SECTION F, PAGE 2)

BF 2.0 2.0 99.0 % K 60 lb / 27.3 kg 400 SERIES : Corrosive

BF 1.5EN 1.5 95.0 % L4 370 g 400 SERIES : Corrosive


B11F3 ENRICHED BF3 < 5 % EB 70 g

BF 4.5SP 4.5 99.995 % L4 400 g 700 SERIES : Semiconductor


SEMICONDUCTOR CO2 < 10 ppm EB 80 g 400 SERIES : Corrosive
PROCESS N2+O2+Ar < 10 ppm
GAS SO2 < 10 ppm
SiF4 < 20 ppm

BF 2.5SP 2.5 99.5 % L4 400 g 700 SERIES : Semiconductor


SEMICONDUCTOR N2+O2+Ar < 4000 ppmw EB 80 g 400 SERIES : Corrosive
PROCESS SO2 < 20 ppmw
GAS SiF4 < 300 ppmw

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
Use the convenient Praxair Fax to place
STYLE / CGA psig / kPa, gauge lb / kg orders for your specialty gases and equipment.
K/ 330 1550 / 10687 195 / 89
L4 / 330 / 642 675 / 4654 11 / 5
EB / 330 700 / 4826 6/ 3
EB / 330 600 / 4137 5/ 2
C
9
PURE GASES

1,3 BUTADIENE
TRANSPORTINFORMATION: FORMULA: C4H6
UN No. 1010
MSDS REFERENCE: 4571
CAS NO.: 106 -- 99 -- 0
GENERAL DESCRIPTION:
Butadienes Butadienes, Butadienes
Shipping Name: inhibited Colorless, flammable, liquified
gas with a mildly aromatic odor.
Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

BD 2.8RS 2.8 99.8 wt% RB 200 g 300 SERIES : Non-corrosive


RESEARCH (liquid phase) 200 SERIES : Non-corrosive

Lot analysis supplied with each container.

BD 2.5IS 2.5 99.5 wt% FE 12 lb / 5.44 kg 300 SERIES : Non-corrosive


INSTRUMENT (liquid phase) 200 SERIES : Non-corrosive
Propadiene < 5 ppmw
1,2 Butadiene < 10 ppmw
Butadiene dimer < 400 ppmw
Butenes < 4000 ppmw
C5 < 50 ppmw
Sulfur < 1 ppmw

BD 2.0 2.0 99.0 wt% FX 135 lb / 61.22 kg 300 SERIES : Non-corrosive


(liquid phase) FE 12 lb / 5.44 kg 200 SERIES : Non-corrosive
Propadiene < 5 ppmw
1,2 Butadiene < 50 ppmw
Butadiene dimer < 1000 ppmw
Butenes < 5000 ppmw
C5 < 100 ppmw
Sulfur < 1 ppmw

FX and FE cylinders available with eductor tube upon request.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
Because of extreme reactivity and tendency to
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg polymerize, 1, 3 Butadiene is shipped with an
inhibitor.
FX / 510 21.4 / 148 227 / 103
FE / 510 21.4 / 148 32 / 15
RB / 510 21.4 / 148 6/3
C
10
PURE GASES

NORMAL BUTANE
TRANSPORTINFORMATION: FORMULA: C4H10
UN No. 1011
MSDS REFERENCE: 4572
CAS NO.: 106 -- 97 -- 8
GENERAL DESCRIPTION:

Shipping Name: Butane Butane Butane Colorless, flammable, liquified gas with a
natural gas odor.
Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

BU 3.0RS 3.0 99.9 wt% RB 200 g 400 SERIES : Non-Corrosive


RESEARCH (liquid phase)

Lot analysis supplied with each container.

BU 2.5IS 2.5 99.5 wt% FX 120 lb / 54.42 kg 400 SERIES : Non-Corrosive


INSTRUMENT (liquid phase) FE 11 lb / 5.00 kg
H2O < 5 ppm
Propane < 500 ppmw
Isobutane < 2500 ppmw
C5 < 1000 ppmw
Sulfur < 1 ppmw

BU 2.0 2.0 99.0 wt% FX 120 lb / 54.42 kg 300 SERIES : Non-Corrosive


(liquid phase) FE 11 lb / 5.00 kg 200 SERIES : Non-Corrosive
H2O < 10 ppm
Propane < 1000 ppmw
Isobutane < 5000 ppmw
C5 < 2000 ppmw
Sulfur < 2 ppmw

FX and FE cylinders available with eductor tube upon request.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
See our full line of hydrocarbon products in
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg Section E - Petrochemical.
FX / 510 16.3 / 112 215 / 98
FE / 510 16.3 / 112 31 / 14
RB / 510 16.3 / 112 6/3
C
11
PURE GASES

1 - BUTENE
TRANSPORTINFORMATION: FORMULA: C4H8
UN No. 1012
MSDS REFERENCE: 6214
CAS NO.: 106 -- 98 -- 9
GENERAL DESCRIPTION:

Shipping Name: Butylene Butylene Butylene Colorless, flammable, liquified gas


with a slightly aromatic odor.
Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

BT 3.0RS 3.0 99.9 wt% RB 200 g 400 SERIES : Non-corrosive


RESEARCH (liquid phase)

Lot analysis supplied with each container

BT 2.0 2.0 99.0 wt% FX 128 lb / 58.05 kg 300 SERIES : Non-corrosive


(liquid phase) FE 12 lb / 5.44 kg 200 SERIES : Non-corrosive
H2O < 10 ppm
n-Butane < 2000 ppmw
Isobutane < 1000 ppmw
Isobutylene < 1000 ppmw
2-Butenes < 3000 ppmw
Sulfur < 2 ppmw

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
See our full line of hydrocarbon products in
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg Section E - Petrochemical.
FX / 510 23.5 / 162 225 / 102
FE / 510 23.5 / 162 32 / 15
RB / 510 23.5 / 162 6/3
C
12
PURE GASES

CIS - 2 - BUTENE
TRANSPORTINFORMATION: FORMULA: C4H8
UN No. 1075
MSDS REFERENCE: 4577
CAS NO.: 590 -- 18 -- 1
GENERAL DESCRIPTION:
Petroleum Gases Petroleum Gases, Petroleum Gases
Shipping Name: liquified Colorless, flammable, liquified gas with a
slightly aromatic odor
Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

CB 2.0 2.0 99.0 wt% FE 12 lb / 5.45 kg 300 SERIES : Non-corrosive


(liquid phase) 200 SERIES : Non-corrosive
trans-2-Butene < 0.7 wt%

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information See our full line of hydrocarbon products in


CYLINDER PRESSURE GROSS WEIGHT
Section E - Petrochemical.
STYLE / CGA psig / kPa, gauge lb / kg
FE / 510 13 / 90 32 / 15 Praxair, your source for technical support.

C
13
PURE GASES

TRANS - 2 - BUTENE
TRANSPORTINFORMATION: FORMULA: C4H8
UN No. 1075
MSDS REFERENCE: 4578
CAS NO.: 624 -- 64 -- 6
GENERAL DESCRIPTION:
Petroleum Gases Petroleum Gases, Petroleum Gases
Shipping Name: liquified Colorless, flammable, liquified gas with a
slightly aromatic odor.
Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

TB 2.0 2.0 99.0 wt% FE 12 lb / 5.45 kg 300 SERIES : Non-corrosive


(liquid phase) 200 SERIES : Non-corrosive
n-Butane < 0.5 wt%
1 - Butene < 0.2 wt%
cis-2-Butene < 0.2 wt%

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
See our full line of hydrocarbon products in
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg
Section E - Petrochemical.
FE / 510 15 / 103 32 / 15 Praxair’s extensive distribution network
ensures on-time delivery.
C
14
PURE GASES

CARBON DIOXIDE
TRANSPORTINFORMATION: FORMULA: CO2
UN No. 1013
MSDS REFERENCE: 4574
CAS NO.: 124 -- 38 -- 9
GENERAL DESCRIPTION:

Shipping Name: Carbon Dioxide Carbon Dioxide Carbon Dioxide Colorless, odorless, nonflammable, slightly
acidic, liquified gas.
Hazard Class: 2.2 2.2 2.2

Nonflammable Nonflammable Nonflammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

CD 4.8RS 4.8 99.998 % K 60 lb / 27.2 kg 400 SERIES : Non-corrosive


RESEARCH CO < 0.5 ppm F 100 L
H2O < 3 ppm RB 25 L
N2 < 10 ppm
O2 < 2 ppm
THC < 4 ppm

CD 4.8SE 4.8 99.998 % AS 40 lb / 18.2 kg SFE Kit (see page F69)


SUPERCRITICAL O2 < 2 ppm
FLUID H2O < 0.5 ppm
EXTRACTION N2 < 5 ppm
H2 < 0.1 ppm
CO < 0.1 ppm
THC (as CH4) < 2 ppm
Total Extractable Hydrocarbons < 10 ppb
(as Dodecane)
Total Extractable Halocarbons < 100 ppb
(as CCL4)

Cylinder supplied with eductor tube and 2-way valve.


Can be supplied with 2000 psig helium headspace pressure.

CD 4.5SC 4.5 99.995 % AS 40 lb / 18.2 kg SFC Kit (see page F69)


SUPERCRITICAL O2 < 5 ppm
FLUID H2O < 1 ppm
CHROMATOGRAPHY N2 < 10 ppm
H2 < 0.1 ppm
CO < 0.1 ppm
THC (as CH4) < 2 ppm
Total Extractable Hydrocarbons < 50 ppb
(as Dodecane)

Cylinder supplied with eductor tube and 2-way valve.


Can be supplied with 2000 psig helium headspace pressure.

CD 4.0AN 4.0 99.99 % K 60 lb / 27.2 kg 308 SERIES : Special Purpose


ANAEROBIC O2 < 10 ppm Q 20 lb / 9.07 kg

CD 4.0IS 4.0 99.99 % K 60 lb / 27.2 kg 308 SERIES : Special Purpose


INSTRUMENT O2 < 15 ppm Q 20 lb / 9.1 kg
H2O < 10 ppm
C
15
PURE GASES

CARBON DIOXIDE

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 ( SECTION F, PAGE 2)

CD 4.0LS 4.0 99.99 % K 60 lb / 27.2 kg 308 SERIES : Special Purpose


LASER H2O < 5 ppm Q 20 lb / 9.1 kg
THC(as CH4) < 1 ppm

CD 3.0 3.0 99.9 % K 60 lb / 27.2 kg 308 SERIES : Special Purpose


Q 20 lb / 9.1 kg

CD 4.8SP 4.8 99.998 % AT 64 lb / 29.0 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 2 ppm K 60 lb / 27.2 kg 308 SERIES : Special Purpose
PROCESS H2O < 3 ppm
GAS N2 < 10 ppm
CH4 < 4 ppm
CO < 0.5 ppm
H2 < 0.5 ppm

CD 4.0SP 4.0 99.99 % AT 64 lb / 29.0 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 10 ppm K 60 lb / 27.2 kg 308 SERIES : Special Purpose
PROCESS H2O < 10 ppm
GAS N2 < 50 ppm
CH4 < 5 ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information Bulk quantities available. Praxair is the


CYLINDER PRESSURE GROSS WEIGHT world’s largest supplier of carbon dioxide.
STYLE / CGA psig / kPa, gauge lb / kg Praxair’s carbon dioxide grades are designed
AT / 320 / 716 830 / 5722 156 / 71 for maximum performance.
AS / 320 / 716 830 / 5722 89 / 40
K/ 320 / 716 830 / 5722 193 / 88 Available with eductor tube.
Q/ 320 830 / 5722 86 /8
F/ 320 830 / 5722 18 /8 See Section E - Medical Gases for Carbon
RB / 320 830 / 5722 6 /3 Dioxide - U.S.P. Grade.
C See page C75 for liquid carbon dioxide.
16
PURE GASES

CARBON MONOXIDE
TRANSPORTINFORMATION: FORMULA: CO
UN No. 1016
MSDS REFERENCE: 4576
CAS NO.: 630 -- 08 -- 0
Carbon Monoxide, Carbon Monoxide Carbon Monoxide, GENERAL DESCRIPTION:

Shipping Name: Compressed Compressed Colorless, odorless, toxic, flammable gas.

Hazard Class: 2.3 2.3 (2.1) 2.3

Toxic Gas, Toxic Gas, Toxic Gas,


Label: Flammable Gas Flammable Flammable Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

CO 4.0RS 4.0 99.99 % F 100 L 400 SERIES : Non-corrosive


RESEARCH O2< 10 ppm RB 45 L
H2O< 5 ppm
N2< 10 ppm
THC< 5 ppm
CO2< 10 ppm
Ar< 10 ppm
CH4< 5 ppm

CO 3.0UH 3.0 99.9 % K 181 / 5.02 400 SERIES : Non-corrosive


ULTRA Sum of O2, H2O, N2,
HIGH CO2, CH4 < 1000 ppm
PURITY

CO 2.5 2.5 99.5 % T 244 / 6.77 400 SERIES : Non-corrosive


O2< 100 ppm K 181 / 5.02
H2O< 5 ppm Q 61 / 1.69
N2< 4500 ppm F 12 / 0.33
CO2< 100 ppm

CO 1.85 1.85 98.5 % T 244 / 6.77 400 SERIES : Non-corrosive


H2O< 20 ppm K 181 / 5.02
Q 61 / 1.69
F 12 / 0.33

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information Bulk quantities available upon request.


CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg
T / 350 2000 / 13789 160 / 73
K / 350 1660 / 11445 145 / 66
Q / 350 1660 / 11445 69 / 36
F / 350 1660 / 11445 16 / 7
F / 350 467 / 3220 16 / 7
RB / 350 1500 / 10342 6/3
C
10 17
PURE GASES

CHLORINE
TRANSPORTINFORMATION: FORMULA:
Cl2
UN No. 1017
MSDS REFERENCE: 4580
CAS NO.: 7782 -- 50 -- 5
GENERAL DESCRIPTION:

Shipping Name: Chlorine Chlorine Chlorine Greenish-yellow, highly toxic, corrosive,


oxidizing, liquified gas with a pungent,
Hazard Class: 2.3 2.3 (5.1) 2.3 irritating odor.

Toxic Gas, Poison Gas, Toxic Gas,


Label: Corrosive Oxidizing Corrosive

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

CL 5.0RS 5.0 99.999 % RB 1 lb / 454 g 400 SERIES : Corrosive


RESEARCH O2 < 1 ppm
N2 < 2 ppm
H2O < 2 ppm
CO2 < 4 ppm
CO < 0.1 ppm
THC < 0.1 ppm

CL 2.5 2.5 99.5 % K 100 lb / 45.4 kg 455 SERIES : Special Purpose

CL 5.0SP 5.0 99.999 % K 70 lb / 31.75 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 1 ppm 400 SERIES : Corrosive
PROCESS N2 < 3 ppm
GAS H2O < 1 ppm
CO2 < 5 ppm
CO < 1 ppm
CH4 < 1 ppm

CL 4.0SP 4.0 99.99 % K 100 lb / 45.4 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 50 ppm Q 40 lb / 18.1 kg 400 SERIES : Corrosive
PROCESS N2 < 50 ppm
GAS CO2 < 30 ppm
CO < 5 ppm
CH4 < 1 ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
Praxair gas cabinets are engineered to provide
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg reliable and safe gas delivery.
K / 660 / 728 85 / 586 235 / 107
Q / 660 / 728 85 / 586 107 / 49
RB / 660 85 / 586 6/3

C
18 11
PURE GASES

DEUTERIUM
TRANSPORTINFORMATION: FORMULA: D2
UN No. 1957
MSDS REFERENCE: 4585
CAS NO.: 7782 -- 39 -- 0
GENERAL DESCRIPTION:
Deuterium, Deuterium Deuterium,
Shipping Name: Compressed Compressed Colorless, odorless, flammable gas;
an isotope of hydrogen.
Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

DT 2.7 2.7 99.7 % K 5,000 L 400 SERIES : Non-corrosive


Sum of N2, O2, H2O, Q 1,800 L
DH, THC < 0.3% F 100 L

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg
K / 350 1786 / 12314 135 / 61
Q / 350 1918 / 13224 16 / 7
F / 350 1918 / 13224 16 / 7
C
19
PURE GASES

DIBORANE

TRANSPORTINFORMATION: FORMULA: B2H6


UN No. 1911
MSDS REFERENCE: 4586
CAS NO.: 19287 -- 45 -- 7
GENERAL DESCRIPTION:
Diborane, Diborane Diborane,
Shipping Name: Compressed Compressed Colorless, unstable, highly toxic,
flammable gas with a sickly, sweet odor.
Hazard Class: 2.3 2.3 (2.1) 2.3

Toxic Gas, Toxic Gas, Toxic Gas,


Label: Flammable Gas Flammable Flammable Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

DB 2.0SP 2.0 99.0 % 700 SERIES : Semiconductor


SEMICONDUCTOR N2< 100 ppm 400 SERIES : Corrosive
PROCESS CO2< 160 ppm
GAS CH4< 400 ppm
H2< 5000 ppm
Higher Boranes < 500 ppm

Diborane is not available in pure form because of chemical instability. It is available in mixtures with carrier gases of Argon, Helium, Hydrogen, Nitrogen, and Silane.

SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

For additional information on our semiconductor


process gases, see Section E - Semiconductor.

C
20
PURE GASES

DICHLOROSILANE
TRANSPORTINFORMATION: FORMULA: SiH2Cl2
UN No. 2189
MSDS REFERENCE: 4587
CAS NO.: 4109 -- 96 -- 0
GENERAL DESCRIPTION:

Shipping Name: Dichlorosilane Dichlorosilane Dichlorosilane Colorless, highly toxic, corrosive,


flammable, liquified gas with a sharp,
Hazard Class: 2.3 2.3 (2.1) 2.3
hydrochloric acid odor.
Toxic Gas, Toxic Gas, Toxic Gas,
Flammable Gas, Flammable Flammable Gas,
Label: Corrosive Corrosive

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

DI 2.7SP 2.7 99.7 % SA 95 lb / 43.09 kg 700 SERIES : Semiconductor


SEMICONDUCTOR Inert Gas < 1000 ppm 400 SERIES : Corrosive
PROCESS Monochlorosilane < 800 ppmw
GAS Trichlorosilane < 2000 ppmw
Silicon Tetrachloride < 300 ppmw
C < 0.05 ppmw
Al < 0.04 ppbw
As < 0.03 ppbw
B < 0.02 ppbw
Fe < 3 ppbw
P < 0.05 ppbw
Resistivity > 400 Ohm-cm

DI 2.0SP 2.0 99.0 % K 90 lb / 40.8 kg 700 SERIES : Semiconductor


SEMICONDUCTOR Inert Gas < 10,000 ppm 400 SERIES : Corrosive
PROCESS Other SiClx < 10,000 ppmw
GAS C < 2 ppmw
Al < 0.1 ppbw
As < 0.1ppbw
B < 0.1ppbw
Fe < 10 ppbw
P < 0.1 ppbw
Resistivity > 150 Ohm-cm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
For additional information on our semiconductor
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg process gases, see Section E - Semiconductor.
K / 678 / 636 9 / 62 225 / 102
SA / 678 / 636 9 / 62 133 / 60

C
21
PURE GASES

DIMETHYL ETHER
TRANSPORTINFORMATION: FORMULA: (CH3)2O
UN No. 1033
MSDS REFERENCE: 4589
CAS NO.: 115 -- 10 -- 6
GENERAL DESCRIPTION:

Shipping Name: Dimethyl Ether Dimethyl Ether Dimethyl Ether Colorless, flammable, liquified gas with an
ethereal odor.
Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

DE 2.5 2.5 99.5 % FX 100 lb / 45.36 kg 200 SERIES : Non-corrosive


(liquid phase) FE 18 lb / 8.16 kg

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
See our full line of safety equipment and gas
STYLE / CGA psig / kPa, gauge lb / kg cabinets in Section F.
FX / 510 623 / 430 180 / 82
FE / 510 623 / 430 40 / 18

C
22
PURE GASES

DIMETHYLAMINE
TRANSPORTINFORMATION: FORMULA: (CH3)2NH
UN No. 1032
MSDS REFERENCE: 4588
CAS NO.: 124 -- 40 -- 3
GENERAL DESCRIPTION:
Dimethylamine, Dimethylamine, Dimethylamine,
Shipping Name: Anhydrous anhydrous Anhydrous Colorless, toxic, flammable, alkaline gas with a
fishy odor in lower concentrations, and an
Hazard Class: 2.1 2.1 (8) 2.1
ammoniacal odor in higher concentrations.
Flammable Flammable Flammable
Label: Gas Gas, Corrosive Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

DA 2.0 2.0 99.0 % FX 135 lb / 61.2 kg 455 SERIES : Special Purpose


(liquid phase)

FX cylinder is equipped with a goose neck eductor tube.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
Praxair, your full line supplier for specialty
STYLE / CGA psig / kPa, gauge lb / kg gases and equipment.
FX / 240 / 705 11.3 / 78 215 / 98

C
23
PURE GASES

DISILANE
TRANSPORTINFORMATION: FORMULA: Si2H6
UN No. 1954
MSDS REFERENCE: 4825
CAS NO.: 1590 -- 87 -- 0
Compressed Gases, Compressed gas Compressed Gases,
GENERAL DESCRIPTION:
Flammable, N.O.S. flammable, n.o.s Flammable, N.O.S.
Shipping Name: (disilane) Colorless, poison, pyrophoric, flammable gas
with a repulsive, suffocating odor.
Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

DS 4.8SP 4.8 99.998 %* G 1000 g 700 SERIES : Semiconductor


SEMICONDUCTOR H2O < 1 ppm 400 SERIES : Corrosive
PROCESS THC < 1 ppm
GAS Ar+O2 < 1 ppm
CO2 < 1 ppm
SiH4 < 1000 ppm
SiHXCly< 0.2 ppm
N2 < 2 ppm
Higher Silanes < 50 ppm
Siloxanes < 5 ppm
Resistivity ≥ 1000 Ohm - cm

*Excluding silane and higher silanes

Contact your local Praxair representative for additional packages and content.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
For additional information on our semiconductor
STYLE / CGA psig / kPa, gauge lb / kg process gases, see Section E - Semiconductor.
G / 350 / 632 33 / 228 33 / 15

C
24
PURE GASES

ETHANE
TRANSPORTINFORMATION: FORMULA: C2H6
UN No. 1035
MSDS REFERENCE: 4592
CAS NO.: 74 -- 84 -- 0
GENERAL DESCRIPTION:

Shipping Name: Ethane Ethane Ethane Colorless, odorless, flammable, liquified gas.

Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

ET 5.0RS 5.0 99.999 % RB 150 g 400 SERIES : Non-corrosive


RESEARCH H2O < 3 ppm
N2 < 3 ppm
O2 < 1 ppm
CO2+CO < 2 ppm
Other THC < 6 ppm

Lot analysis supplied with each container.

ET 2.0 2.0 99.0 % K 32 lb / 14.5 kg 300 SERIES : Non-corrosive


Methane < 50 ppm Q 11 lb / 5.0 kg 200 SERIES : Non-corrosive
Ethylene < 4000 ppm G 5 lb / 2.3 kg
Propane < 400 ppm
Propylene < 1000 ppm
C-3’s < 1500 ppm
Sulfur < 1 ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
See our full line of hydrocarbon products in
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg Section E - Petrochemical.
K / 350 543 / 3744 165 / 75
Q / 350 543 / 3744 76 / 35
G / 350 543 / 3744 36 / 16
RB / 350 543 / 3744 6/3
C
25
PURE GASES

ETHYL CHLORIDE
TRANSPORTINFORMATION: FORMULA: C2H5Cl
UN No. 1037
MSDS REFERENCE: 4597
CAS NO.: 75 -- 00 -- 3
GENERAL DESCRIPTION:

Shipping Name: Ethyl Chloride Ethyl Chloride Ethyl Chloride Colorless, flammable gas.

Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

EC 3.0 3.0 99.9 wt% FX 190 lb / 86.1 kg 300 SERIES : Non-Corrosive


(liquid phase) FE 18 lb / 8.1 kg 200 SERIES : Non-Corrosive
Acidity (As HCl) < 10 ppmw
Aldehydes < 100 ppmw
Non-Volatile Residue < 10 ppmw
H2O < 100 ppmw

FX cylinder is available with eductor tube upon request.

EC 2.7 2.7 99.7 % FX 190 lb / 86.1 kg 300 SERIES : Non-Corrosive


(liquid phase) FE 18 lb / 8.1 kg 200 SERIES : Non-Corrosive

FX cylinder is available with eductor tube upon request.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
Praxair, high quality specialty gases and
STYLE / CGA psig / kPa, gauge lb / kg equipment for your applications.
FX / 300 5.3 / 36 265 / 120
FE / 300 5.3 / 36 38 / 17

C
26
PURE GASES

ETHYLENE
TRANSPORTINFORMATION: FORMULA: C2H4
UN No. 1962
MSDS REFERENCE: 4598
CAS NO.: 74 -- 85 -- 1
GENERAL DESCRIPTION:
Ethylene, Ethylene Ethylene,
Shipping Name: Compressed Compressed Colorless, flammable gas with a sweet
odor and taste.
Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

EY 5.0RS 5.0 99.999 % RB 150 g 400 SERIES : Non-corrosive


RESEARCH O2 < 2 ppm
N2 < 2 ppm
CO < 0.5 ppm
CO2 < 1 ppm
C2H2 < 0.5 ppm
C2H6 < 5 ppm
Other HC < 5 ppm
H2O < 3 ppm

EY 3.0PL* 3.0 99.9 % T 37 lb / 16.7 kg 300 SERIES : Non-corrosive


POLYMER O2 < 10 ppm K 30 lb / 13.6 kg 200 SERIES : Non-corrosive
N2 < 50 ppm Q 10 lb / 4.5 kg
CO < 3 ppm
CO2 < 10 ppm
C2H2 < 6 ppm
C2H6 < 100 ppm
Other HC < 100 ppm
H2O < 5 ppm
Sulfur < 1 ppm

EY 2.5* 2.5 99.5 % T 37 lb / 16.7 kg 300 SERIES : Non-corrosive


O2 < 25 ppm K 30 lb / 13.6 kg 200 SERIES : Non-corrosive
N2 < 100 ppm Q 10 lb / 4.5 kg
CO < 5 ppm
CO2 < 15 ppm
Other HC < 2000 ppm
H2O < 5 ppm

EY 1.85* 1.85 98.5 % T 37 lb / 16.7 kg 200 SERIES : Non-corrosive


K 30 lb / 13.6 kg 100 SERIES : Non-corrosive
Q 10 lb / 4.5 kg

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information *Not registered for FIFRA regulated


CYLINDER PRESSURE GROSS WEIGHT
applications. For FIFRA applications, refer
STYLE / CGA psig / kPa, gauge lb / kg
to Section E.
T / 350 1600 / 11031 180 / 82 For fruit ripening applications, please call
K / 350 1200 / 8274 163 / 74
your local Praxair representative.
Q / 350 1200 / 8274 75 / 34
RB / 350 1200 / 8274 6/3
See our full line of hydrocarbon products in
Section E - Petrochemical. C
27
PURE GASES

ETHYLENE OXIDE
TRANSPORTINFORMATION: FORMULA: C2H4O
UN No. 1040
MSDS REFERENCE: 4798
CAS NO.: 75 -- 21 -- 8
GENERAL DESCRIPTION:

Shipping Name: Ethylene Oxide Ethylene Oxide Ethylene Oxide Colorless, toxic, flammable, liquified gas
with an ethereal odor above 500 ppm.
Hazard Class: 2.3 2.1 2.3

Toxic Gas, Flammable Gas Toxic Gas,


Label: Flammable Gas Flammable Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

EO 3.0 3.0 99.9 % DM* 400 lb / 181.4 kg Manual Valve


(liquid phase) RB 0.5 lb / 0.22 kg Stainless Steel
Acidity < 20 ppmw
Aldehydes < 30 ppmw
H2O < 30 ppmw
Residue < 0.005 g/ml

* Pressurized with nitrogen to 50 psig / 345 kPa; equipped with diptube and nitrogen pressurization valve.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information Not registered for fumigant use. See Section E


CYLINDER PRESSURE GROSS WEIGHT for Sterilant Gases.
STYLE / CGA psig / kPa, gauge lb / kg
DM / 510 50 / 345 690 / 313 Not registered for FIFRA regulated applications
RB / 510 7 / 42 6/3 in the USA.
C
28
PURE GASES

HALOCARBON-14 (TETRAFLUOROMETHANE)

TRANSPORTINFORMATION: FORMULA: CF4


UN No. 1982
MSDS REFERENCE: 4665
CAS NO.: 75 -- 73 -- 0
Tetrafluoromethane, Tetrafluoromethane Tetrafluoromethane, GENERAL DESCRIPTION:

Shipping Name: Compressed Compressed Colorless, nonflammable gas.

Hazard Class: 2.2 2.2 2.2

Nonflammable Nonflammable Nonflammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

HA 14 4.7SP 4.7 99.997 % AT 72 lb / 32.7 kg 700 SERIES : Semiconductor


SEMICONDUCTOR Ar + O2 < 5 ppm 400 SERIES : Non-corrosive
PROCESS CO < 1 ppm
GAS CH4 < 1 ppm
SF6 < 1 ppm
H2O < 1 ppm
CO2 < 1 ppm
N2 < 15 ppm
Other Halocarbons < 4 ppm
Acidity (HF) < 0.1 ppmw

Cylinder equipped with high integrity connection CGA 716.

HA 14 3.7SP 3.7 99.97 % AT 72 lb / 32.7 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 + Ar < 40 ppm K 65 lb / 29.5 kg 400 SERIES : Non-corrosive
PROCESS N2 < 150 ppm 300 SERIES : Non-corrosive
GAS CO < 10 ppm
CO2 < 2 ppm
SF6 < 5 ppm
H2O < 1 ppm
Other Halocarbons < 4 ppm
Acidity (HF) < 0.1 ppmw

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
For additional information on our semiconductor
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg process gases, see Section E - Semiconductor.
K / 320 1800 / 12410 200 / 91
AT / 320 / 716 1800 / 12410 172 / 91

C
29
PURE GASES

HALOCARBON-22 (CHLORODIFLUOROMETHANE)

TRANSPORTINFORMATION: FORMULA: CHCIF2


UN No. 1018
MSDS REFERENCE: 4667
CAS NO.: 75 -- 45 -- 6
GENERAL DESCRIPTION:
Chlorodi- Chlorodi- Chlorodi-
Shipping Name: fluoromethane fluoromethane fluoromethane Colorless, nearly odorless,
nonflammable, liquified gas.
Hazard Class: 2.2 2.2 2.2

Nonflammable Nonflammable Nonflammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

HA 22 3.0 3.0 99.9 % FC * 125 lb / 56.7 kg 300 SERIES : Non-corrosive


(liquid phase) FE 20 lb / 9.1 kg 200 SERIES : Non-corrosive
D7 ** 25 lb / 11.3 kg

*Equipped with dual phase valve.


**Non-refillable container.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg
FC / 660 123 / 848 175 / 79
FE / 660 123 / 848 42 / 19
D7 / 165 123 / 848 31 / 14
C
30
PURE GASES

HALOCARBON-23 (TRIFLUOROMETHANE)

TRANSPORTINFORMATION: FORMULA: CHF3


UN No. 1984
MSDS REFERENCE: 4668
CAS NO.: 75 -- 46 -- 7
GENERAL DESCRIPTION:

Shipping Name: Trifluoromethane Trifluoromethane Trifluoromethane Colorless, nonflammable, liquified gas


with a slight ethereal odor.
Hazard Class: 2.2 2.2 2.2

Nonflammable Nonflammable Nonflammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

HA 23 4.5SP 4.5 99.995 % AT 75 lb / 34.0 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 + N2 < 15 ppm 300 SERIES : Non-corrosive
PROCESS CO2 < 2 ppm
GAS CH4 < 1 ppm
H2O < 4 ppm
Other Halocarbons < 10 ppm
Acidity (HF) < 1 ppmw

Cylinder equipped with high integrity connection CGA 716.

HA 23 2.0SP 2.0 99.0 % AT 75 lb / 34.0 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 + N2< 5000 ppm K 70 lb / 31.8 kg 300 SERIES : Non-corrosive
PROCESS H2O < 10 ppmw 200 SERIES : Non-corrosive
GAS Other Halocarbons < 1000 ppm
Acidity (HCl) < 0.1 ppmw

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information Praxair, your source for technical support.


CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg
For additional information on our semiconductor
AT / 660 / 716 635 / 4378 173 / 79 process gases, see Section E - Semiconductor.
K / 660 635 / 4378 205 / 93

C
31
PURE GASES

HALOCARBON-116 (HEXAFLUOROETHANE)
TRANSPORTINFORMATION: FORMULA: C2F6
UN No. 2193
MSDS REFERENCE: 4670
CAS NO.: 76 -- 16 -- 4
GENERAL DESCRIPTION:
Hexafluoroethane, Hexafluoroethane Hexafluoroethane,
Shipping Name: Compressed Compressed Colorless, odorless, nonflammable,
liquified gas.
Hazard Class: 2.2 2.2 2.2

Nonflammable Nonflammable Nonflammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

HA 116 4.6SP 4.6 99.996 % AT 114 lb / 51.7 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 5 ppm 300 SERIES : Non-corrosive
PROCESS N2 < 20 ppm 200 SERIES : Non-corrosive
GAS CO < 1 ppm
CO2 < 3 ppm
H2O < 2 ppm
Other Halocarbons < 10 ppm
Acidity (HCl) < 0.05 ppmw

Cylinder equipped with high integrity connection CGA 716.

HA 116 3.6SP 3.6 99.96 % AT 114 lb / 51.7 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 25 ppm K 95 lb / 43.1 kg 300 SERIES : Non-corrosive
PROCESS N2 < 100 ppm 200 SERIES : Non-corrosive
GAS CO < 5 ppm
CO2 < 5 ppm
H2O < 10 ppm
Other Halocarbons < 50 ppm
Acidity (HCl) < 0.1 ppmw

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
Praxair’s extensive distribution network ensures
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg
on-time delivery.

AT / 320 /716 430 / 2965 212 / 96 Bulk quantities available upon request.
K / 320 430 / 2965 230 / 105

C
32
PURE GASES

HALOCARBON-134A (1,1,1,2-TETRAFLUOROETHANE)
TRANSPORTINFORMATION: FORMULA: C2H2F4
UN No. 3159
MSDS REFERENCE: 6213
CAS NO.: 811 -- 97 -- 2
GENERAL DESCRIPTION:
1, 1, 1, 2 - 1, 1, 1, 2 - 1, 1, 1, 2 -
Shipping Name: Tetrafluoroethane Tetrafluoroethane Tetrafluoroethane Colorless, nonflammable, liquified gas
with slight ethereal odor.
Hazard Class: 2.2 2.2 2.2

Nonflammable Nonflammable Nonflammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

HA 134A 2.8 2.8 99.8% FT 1750 lb / 794 kg 300 SERIES : Non-corrosive


(liquid phase) FC* 125 lb / 56.7 kg 200 SERIES : Non-corrosive
CH4 < 400 ppm
C3H8 < 300 ppm

*Equipped with full length eductor tube for liquid withdrawal.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
For additional information on our semiconductor
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg process gases, see Section E - Semiconductor.
FT / 660 71 / 490 2865 / 1300
Bulk quantities available upon request.
FC / 660 71 / 490 175 / 79

C
33
PURE GASES

HALOCARBON-218 (OCTAFLUOROPROPANE)
TRANSPORTINFORMATION: FORMULA: C3F8
UN No. 2424
MSDS REFERENCE: 4640
CAS NO.: 76 -- 19 -- 7
GENERAL DESCRIPTION:
Octa- Octa- Octa-
Shipping Name: fluoropropane fluoropropane fluoropropane Colorless, nonflammable, liquified gas.

Hazard Class: 2.2 2.2 2.2

Nonflammable Nonflammable Nonflammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

HA 218 2.0 2.0 99.0% K 50 lb / 22.7 kg 300 SERIES : Non-corrosive


(liquid phase) G 15 lb / 6.8 kg 200 SERIES : Non-corrosive
O2 < 200 ppm
N2 < 500 ppm
THC < 10 ppm
H2O < 10 ppm

HA 218 3.6SP 3.6 99.96% K 90 lb / 40.8 kg 700 SERIES : Semiconductor


SEMICONDUCTOR H2O < 10 ppm G 10 lb / 4.5 kg 400 SERIES : Non-corrosive
PROCESS Acidity (HF) < 0.1 ppmw 300 SERIES : Non-corrosive
GAS Sum of N2, O2, CO, CO2 < 400ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information Contact your nearest specialty gases production


CYLINDER PRESSURE GROSS WEIGHT facility for technical information and assistance.
STYLE / CGA psig / kPa, gauge lb / kg
K / 660 / 716 100 / 689 225 / 102 Not for use in pneumatic retinopexy.
K / 660 100 / 689 183 / 83
G / 660 100 / 689 44 / 20 For additional information on our semiconductor
C G / 660 / 716 100 / 689 39 / 18 process gases, see Section E - Semiconductor.
34
PURE GASES

HELIUM

TRANSPORTINFORMATION: FORMULA: He
UN No. 1046
MSDS REFERENCE: 4602
CAS NO.: 7440 -- 59 -- 7
Helium, Helium Helium, GENERAL DESCRIPTION:

Shipping Name: Compressed Compressed Colorless, odorless, nonflammable inert gas.

Hazard Class: 2.2 2.2 2.2

Nonflammable Nonflammable Nonflammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 ( SECTION F, PAGE 2)

HE 6.0RS 6.0 99.9999 % T 291 / 8.07 400 SERIES : Non-corrosive


RESEARCH/ Ar < 0.5 ppm K 218 / 6.05
CHROMATOGRAPHIC* CO < 0.1 ppm F 100L
CO2 < 0.1 ppm RB 50L
H2 < 0.5 ppm
H2O < 0.2 ppm
N2 < 0.4 ppm
O2 < 0.1 ppm
THC < 0.1 ppm
*For chromatography use, reported purity excludes neon.

HE 5.5EC 5.5 99.9995 % AT 239 / 6.63 400 SERIES : Non-corrosive


ELECTRON O2 < 1 ppm AS 135 / 3.74
CAPTURE CO2 + CO < 1 ppm T 291/ 8.07
DETECTOR THC < 0.1 ppm K 218/ 6.05
N2 < 2 ppm
Ar < 1 ppm
The sum of O2, CO2, THC as CH4, N2 and H20 < 5 ppm. No peaks exceed the equivalent of 50 ppt as Hexachloraethane; 10 ppb as Dodecane (C12).
A chromatogram of the halogen and hydrocarbon analysis is available with each cylinder.

HE 5.5TG 5.5 99.9995% AT 239 / 6.63 400 SERIES : Non-corrosive


TRACE O2 < 1ppm T 291/ 8.07
ANALYTICAL CO2 + CO < 1 ppm K 218/ 6.05
THC < 0.1 ppm
N2 < 2 ppm
Ar < 1 ppm
The sum of O2, CO2, THC as CH4, N2 and H20 < 5 ppm. No peaks exceed the equivalent of 50 ppt as Hexachloraethane; 10 ppb as Dodecane (C12).
Batch analyzed.

HE 5.0UH 5.0 99.999 %* T 291 / 8.07 400 SERIES : Non-corrosive


ULTRA H2O < 2 ppm K 218 / 6.05
HIGH O2 < 1 ppm
PURITY THC < 0.5 ppm
*Neon free basis.

HE 4.7LS 4.7 99.997 % T 291 / 8.07 300 SERIES : Non-corrosive


LASER O2 < 3 ppm K 218 / 6.05 200 SERIES : Non-corrosive
H2O < 3 ppm
THC < 1 ppm

C
35
PURE GASES

HELIUM

Product and Package Information

REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

HE 4.6Z 4.6 99.996 % T 291 / 8.07 300 SERIES : Non-corrosive


ZERO THC < 0.5 ppm K 218 / 6.05 200 SERIES : Non-corrosive
O2 < 3 ppm

HE 4.6OF 4.6 99.996 % T 291 / 8.07 300 SERIES : Non-corrosive


O2 FREE O2 < 0.5 ppm K 218 / 6.05 200 SERIES : Non-corrosive

HE 4.5 4.5 99.995 % 6K 519 / 14.39 492 SERIES : Special Purpose


O2 < 5 ppm 4K 432 / 11.98 492 SERIES : Special Purpose
H2O< 5 ppm 3K 333 / 9.23 492 SERIES : Special Purpose
T 291 / 8.07 300 SERIES : Non-corrosive
K 218 / 6.05 200 SERIES : Non-corrosive
AS 135 / 3.74

HE 6.0SP 6.0 99.9999 % AT 239 / 6.63 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 0.2 ppm AS 135 / 3.74 400 SERIES : Non-corrosive
PROCESS H2O < 0.2 ppm
GAS CO2 < 0.1 ppm
CO < 0.1 ppm
THC < 0.1 ppm
N2 < 0.5 ppm
H2 < 0.1 ppm

HE 5.5SP 5.5 99.9995 % AT 239 / 6.63 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 0.5 ppm K 218 / 6.05 400 SERIES : Non-corrosive
PROCESS H2O < 0.5 ppm
GAS CO2 < 0.5 ppm
CO < 0.5 ppm
THC < 0.5 ppm
N2 < 2 ppm

HE 5.0SP 5.0 99.999 % T 291 / 8.07 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 2 ppm K 218 / 6.05 400 SERIES : Non-corrosive
PROCESS H2O < 3 ppm
GAS CO2 < 1 ppm
CO < 1 ppm
THC < 1 ppm
N2 < 6 ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
Product available in larger quantities, 6, 12 and 16
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg
pack cylinder clusters, tube trailers and dewars.

6K / 677 6000 / 41368 308 / 140 See Pg C76 for cryogenic liquid helium.
4K / 680 4500 / 31026 151 / 69
3K / 680 3500 / 24131 192 / 87 See Section E - Medical Gases for Helium -
T/ 580 / 718 2640 / 18202 146 / 66 U.S.P. Grade.
K/ 580 / 718 2200 / 15168 135 / 61
AT / 580 2200 / 15168 97 / 44 Praxair is the world’s recognized leader in
AS / 580 2000 / 13790 49 / 22 helium production and purification.
F/ 580 486 / 3351 16 / 7
C RB / 580 1775 / 12238 6/ 3

36
PURE GASES

HYDROGEN
TRANSPORTINFORMATION: FORMULA: H2
UN No. 1049
MSDS REFERENCE: 4604
CAS NO.: 1333 -- 74 -- 0
GENERAL DESCRIPTION:
Hydrogen, Hydrogen Hydrogen,
Shipping Name: Compressed Compressed Colorless, odorless, flammable gas.

Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 ( SECTION F, PAGE 2)

HY 6.0RS 6.0 99.9999 % T 261 / 7.24 400 SERIES : Non-corrosive


RESEARCH O2 < 0.1 ppm K 196 / 5.44
H2O < 0.5 ppm F 100L
CO2 < 0.1 ppm RB 50L
CO < 0.1 ppm
THC < 0.1 ppm
N2 < 0.5 ppm
Ar < 0.1 ppm

HY 5.0UH 5.0 99.9999 % T 261 / 7.24 400 SERIES : Non-corrosive


ULTRA H2O < 3 ppm K 196 / 5.44
HIGH O2 < 1 ppm Q 65 / 1.80
PURITY THC < 0.5 ppm

HY 4.5TC 4.5 99.995 % T 261 / 7.24 300 SERIES : Non-corrosive


TOTAL H2O < 5 ppm 200 SERIES : Non-corrosive
ORGANIC CO2 < 0.1 ppm
CARBON CO < 0.1 ppm
THC < 0.1 ppm

HY 4.5Z 4.5 99.995 % T 261 / 7.24 300 SERIES : Non-corrosive


ZERO H2O < 5 ppm K 196 / 5.44 200 SERIES : Non-corrosive
THC < 0.5 ppm

HY 4.5 4.5 99.995 % 6K 484 / 13.98 492 SERIES : Special Purpose


O2 < 5 ppm 3K 322 / 8.93 492 SERIES : Special Purpose
H2O < 5 ppm T 261 / 7.24 300 SERIES : Non-corrosive
K 196 / 5.44 200 SERIES : Non-corrosive

HY 6.0SP 6.0 99.9999 % AT 234 / 6.49 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 0.2 ppm 400 SERIES : Non-corrosive
PROCESS H2O < 0.2 ppm
GAS CO2 < 0.1 ppm
CO < 0.1 ppm
THC < 0.1 ppm
N2 < 0.5 ppm

C
37
PURE GASES

HYDROGEN

Product and Package Information

REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

HY 5.5SP 5.5 99.9995 % AT 234 / 6.49 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 0.5 ppm 400 SERIES : Non-corrosive
PROCESS H2O < 0.5 ppm
GAS CO2 < 0.5 ppm
CO < 0.5 ppm
THC < 0.5 ppm
N2 < 2 ppm

HY 5.0SP 5.0 99.999 % 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 2 ppm K 196 / 5.44 400 SERIES : Non-corrosive
PROCESS H2O < 3 ppm 300 SERIES : Non-corrosive
GAS CO2 < 1 ppm
CO < 1 ppm
THC < 1 ppm
N2 < 6 ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
See our extensive line of safety products in
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg
Section F.

6K / 703 6000 / 41368 306 / 139 Product available in larger quantities, 6 and
3K / 695 3500 / 24131 190 / 86 12 pack cylinder clusters, tube trailers, VPSA,
AT / 350 / 724 2200 / 15168 95 / 43
membranes and dewars.
T / 350 2400 / 16547 145 / 66
K / 350 2000 / 13789 134 / 61
Q / 350 2000 / 13789 65 / 30 Praxair, your global supplier.
F / 350 486 / 3350 16 / 7
RB / 350 1775 / 12238 6/3 Praxair, your source for technical support.

C
38
PURE GASES

HYDROGEN BROMIDE
TRANSPORTINFORMATION: FORMULA: HBr
UN No. 1048
MSDS REFERENCE: 4605
CAS NO.: 10035 -- 10 -- 6
GENERAL DESCRIPTION:
Hydrogen Bromide, Hydrogen Bromide, Hydrogen Bromide,
Shipping Name: Anhydrous anhydrous Anhydrous Colorless, toxic, corrosive,
nonflammable, liquified gas with
Hazard Class: 2.3 2.3 (8) 2.3
a very irritating odor.
Toxic Gas, Toxic Gas, Toxic Gas,
Label: Corrosive Corrosive Corrosive

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

HB 2.8 2.8 99.8% K 130 lb / 59.0 kg 400 SERIES : Corrosive

HB 4.5SP 4.5 99.995 % K 70 lb / 31.8 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 5 ppm 400 SERIES : Corrosive
PROCESS H2O < 5 ppm
GAS N2 < 20 ppm
CO2 < 20 ppm
CO < 1 ppm
CH4 < 1 ppm
Fe < 1 ppmw

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
See our full line of safety equipment and gas
STYLE / CGA psig / kPa, gauge lb / kg cabinets in Section F.
K / 330 / 634 320 / 2206 205 / 93
K / 330 320 / 2206 265 / 120

C
39
PURE GASES

HYDROGEN CHLORIDE

TRANSPORTINFORMATION: FORMULA: HCl


UN No. 1050
MSDS REFERENCE: 4606
CAS NO.: 7647 -- 01 -- 0
GENERAL DESCRIPTION:
Hydrogen Chloride, Hydrogen Chloride, Hydrogen Chloride,
Shipping Name: Anhydrous anhydrous Anhydrous Colorless, toxic, corrosive,
nonflammable, acidic, liquified gas
Hazard Class: 2.3 2.3 2.3
with a pungent odor.
Toxic Gas, Toxic Gas, Toxic Gas,
Label: Corrosive Corrosive Corrosive

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

HC 2.0 2.0 99.0 % K 60 lb / 27.3 kg 400 SERIES : Corrosive


O2 < 400 ppm G 9 lb / 4.1 kg
H2O < 200 ppm L4 2.8 lb / 1.3 kg
N2 < 1000 ppm RB 0.5 lb / 0.23 kg
THC < 10 ppm
CO2 < 300 ppm
Cl2 < 1 ppm

HC 5.0SP 5.0 99.999 % K 55 lb / 24.9 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 1 ppm 400 SERIES : Corrosive
PROCESS H2O < 1 ppm
GAS N2 < 3 ppm
CO2 < 2 ppm
CO < 2 ppm
CH4 < 1 ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
See our full line of safety equipment and gas
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg
cabinets in Section F.

K / 330 613 / 4226 192 / 87 Product available in ton containers.


K / 330 / 634 613 / 4226 187 / 85
G / 330 613 / 4226 38 / 17
Use the convenient Praxair Fax to place orders
L4 / 330 613 / 4226 12 / 5
C RB / 330 613 / 4226 6/3 for your specialty gases and equipment.
40
PURE GASES

HYDROGEN FLUORIDE

TRANSPORTINFORMATION: FORMULA: HF
UN No. 1052
MSDS REFERENCE: 4608
CAS NO.: 7664 -- 39 -- 3
GENERAL DESCRIPTION:
Hydrogen Fluoride, Hydrogen Fluoride, Hydrogen Fluoride,
Shipping Name: Anhydrous anhydrous Anhydrous Colorless, toxic, corrosive,
nonflammable, liquid with a
Hazard Class: 8 8 (6.1) 8
sharp, pungent odor.
Corrosive, Corrosive, Corrosive,
Label: Toxic Toxic Toxic

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

HF 2.0 2.0 99.0 % RB 0.5 lb / 0.23 kg 400 SERIES : Corrosive

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
Praxair, your full line supplier for specialty
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg gases and equipment.
RB / 670 / 638 0.6 / 4.1 6/3

C
41
PURE GASES

HYDROGEN SULFIDE

TRANSPORTINFORMATION: FORMULA: H2S


UN No. 1053
MSDS REFERENCE: 4611
CAS NO.: 7783 -- 06 -- 4
GENERAL DESCRIPTION:

Shipping Name: Hydrogen Sulfide Hydrogen Sulphide Hydrogen Sulfide Colorless, toxic, corrosive, flammable,
liquified gas with an offensive odor
Hazard Class: 2.3 2.3 2.3
(rotten eggs).
Toxic Gas, Toxic Gas, Toxic Gas,
Label: Flammable Gas Flammable Flammable Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

HS 2.6 2.6 99.6 % K 55 lb / 24.9 kg 408 SERIES : Special Purpose


(liquid phase)

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
See our extensive line of safety products in
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg Section F.
K / 330 252 / 1737 192 / 42

C
42
PURE GASES

ISOBUTANE
TRANSPORTINFORMATION: FORMULA: i-C4H10
UN No. 1969
MSDS REFERENCE: 4613
CAS NO.: 75 -- 28 -- 5
GENERAL DESCRIPTION:

Shipping Name: Isobutane Isobutane Isobutane Colorless, flammable, liquified gas with
a slight odor.
Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

IS 4.0RS 4.0 99.99 wt% RB 200 g 300 SERIES : Non-corrosive


RESEARCH (liquid phase) 200 SERIES : Non-corrosive

Lot analysis supplied with each container.

IS 2.5IS 2.5 99.5 wt% FX 116 lb / 52.6 kg 300 SERIES : Non-corrosive


INSTRUMENT (liquid phase) FE 11 lb / 5.0 kg 200 SERIES : Non-corrosive
H2O < 3 ppm
Propane < 1000 ppm
n-Butane < 3000 ppm
Sulfur < 1 ppm

IS 2.0 2.0 99.0 wt% FX 116 lb / 52.6 kg 300 SERIES : Non-corrosive


(liquid phase) FE 11 lb / 5.0 kg 200 SERIES : Non-corrosive
H2O < 5 ppm
Ethane < 20 ppm
Propane < 3400 ppm
n-Butane < 5000 ppm
1-Butene < 30 ppm
Isobutylene < 300 ppm
Sulfur < 1 ppm

FX and FE cylinders available with eductor tube upon request.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
See our full line of hydrocarbon products in
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg Section E - Petrochemical.
FX / 510 31 / 214 191 / 87 Praxair, high quality specialty gases and
FE / 510 31 / 214 31 / 14
equipment for your applications.
RB / 510 31 / 214 6/3
C
43
PURE GASES

ISOBUTYLENE

TRANSPORTINFORMATION: FORMULA: C4H8


UN No. 1055
MSDS REFERENCE: 4614
CAS NO.: 115 - 11 - 7
GENERAL DESCRIPTION:

Shipping Name: Isobutylene Isobutylene Isobutylene Colorless, flammable, liquified gas with
a coal gas odor.
Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information

REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

IY 3.0RS 3.0 99.9 wt% RB 200 g 300 SERIES : Non-corrosive


RESEARCH (liquid phase) 200 SERIES : Non-corrosive

Lot analysis supplied with each container.

IY 2.0 2.0 99.0 wt% FX 125 lb / 56.7 kg 300 SERIES : Non-corrosive


(liquid phase) FE 12 lb / 5.4 kg 200 SERIES : Non-corrosive
H2O < 5 ppm
Propane < 200 ppm
Propylene < 200 ppm
n-Butane < 3000 ppm
Isobutane < 300 ppm
1-Butene < 3000 ppm
2-Butenes < 500 ppm
Sulfur < 1 ppm

FX and FE cylinders available with eductor tube upon request.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTION G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg
FX / 510 24.3 / 168 200 / 91
FE / 510 24.3 / 168 32 / 15
RB / 510 24.3 / 168 6/3
C
44
PURE GASES

KRYPTON

TRANSPORTINFORMATION: FORMULA: Kr
UN No. 1056
MSDS REFERENCE: 4616
CAS NO.: 7439 -- 90 -- 9
GENERAL DESCRIPTION:
Krypton, Krypton, Krypton,
Shipping Name: Compressed compressed Compressed Colorless, odorless, nonflammable,
inert gas.
Hazard Class: 2.2 2.2 2.2

Nonflammable Nonflammable Nonflammable


Label: Gas Gas Gas

Product and Package Information

REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

KR 5.0RS 5.0 99.999% T 8,000 L 400 SERIES : Non-corrosive


RESEARCH O2 < 2 ppm K 7,000 L 300 SERIES : Non-corrosive
H2O < 3 ppm Q 2,000 L
N2 < 5 ppm D4 300 L
Ar < 1 ppm C 100 L
CO2 < 0.5 ppm RB 50 L
THC < 0.2 ppm
H2 < 1 ppm
Xe < 2 ppm

Other cylinder volumes from 5 liters to 10,000 liters are available.

KR 3.0 3.0 99.9 % T 8,000 L 300 SERIES : Non-corrosive


O2< 10 ppm K 7,000 L
H2O< 10 ppm Q 2,000 L
N2< 50 ppm
THC< 10 ppm

Other cylinder volumes from 5 liters to 10,000 liters are available.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
Praxair, the leader in rare gas production and
STYLE / CGA psig / kPa, gauge lb / kg application technology.
T / 580 1819 / 12541 204 / 93
K / 580 1792 / 12355 187 / 85
Q / 580 1557 / 10735 80 / 37
D4 / 580 1462 / 10080 10 / 5
RB / 580 1377 / 9494 6/3
C / 580 1311 / 9039 6/3 C
45
PURE GASES

METHANE

TRANSPORTINFORMATION: FORMULA: CH4


UN No. 1971
MSDS REFERENCE: 4618
CAS NO.: 74 -- 82 -- 8
GENERAL DESCRIPTION:
Methane, Methane Methane,
Shipping Name: Compressed Compressed Colorless, odorless, flammable gas.

Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information

REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

ME 5.0RS 5.0 99.999 % T 346 / 9.59 400 SERIES : Non-corrosive


RESEARCH O2 < 1 ppm K 255 / 7.07
H2O < 1 ppm F 100 L
N2 < 4 ppm RB 50 L
CO2 < 3 ppm
C2H6 < 2 ppm
C2H4 < 1 ppm
C3H8 < 1 ppm
C3H6 < 1 ppm
CO < 1 ppm

ME 3.7UH 3.7 99.97 % T 346 / 9.59 400 SERIES : Non-corrosive


ULTRA O2 < 10 ppm K 255 / 7.07 300 SERIES : Non-corrosive
HIGH H2O < 5 ppm Q 85 / 2.36
PURITY N2 < 40 ppm F 17 / 0.47
CO + CO2 < 10 ppm
H2 < 10 ppm
CnHm < 50 ppm

ME 2.0 2.0 99.0 % 6K 570 / 15.8 492 SERIES : Special Purpose


CO2 < 100 ppm 3K 423 / 11.7 492 SERIES : Special Purpose
H2O < 10 ppm T 346 / 9.59 300 SERIES : Non-corrosive
N2 < 2000 ppm K 255 / 7.07 200 SERIES : Non-corrosive
O2 < 50 ppm Q 85 / 2.36
F 17 / 0.47

ME 1.3 1.3 93.0 % T 346 / 9.59 300 SERIES : Non-corrosive


K 255 / 7.07 200 SERIES : Non-corrosive
Q 85 / 2.36
F 17 / 0.47

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
See our full line of hydrocarbon products in
STYLE / CGA psig / kPa, gauge lb / kg Section E - Petrochemical.
6K / 703 6000 / 41368 327 / 149
3K / 695 3500 / 24131 207 / 94 Bulk quantities available upon request.
T / 350 2400 / 16547 162 / 74
K / 350 2000 / 13789 144 / 65
Q / 350 2000 / 13789 69 / 31
F / 350 2000 / 13789 16 / 7

C
46
PURE GASES

METHYL BROMIDE
TRANSPORTINFORMATION: FORMULA: CH3Br
UN No. 1062
MSDS REFERENCE: 4620
CAS NO.: 74 -- 83 -- 9
GENERAL DESCRIPTION:

Shipping Name: Methyl Bromide Methyl Bromide Methyl Bromide Colorless, toxic, flammable, liquified
gas with a chloroform-like odor.
Hazard Class: 2.3 2.3 2.3

Label: Toxic Gas Toxic Gas Toxic Gas

Product and Package Information

REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

MB 2.5 2.5 99.5 % Q 45 lb / 20.4 kg 400 SERIES : Non-corrosive


(liquid phase) F 8 lb / 3.6 kg
Acidity (as HBr)< 10 ppm
CH3OH< 200 ppm
Non-Volatile Residue < 100 ppm
H2O < 150 ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
See our full line of safety equipment and gas
STYLE / CGA psig / kPa, gauge lb / kg cabinets in Section F.
Q / 330 13 / 89.63 115 / 52
F / 330 13 / 89.63 22 / 10 For industrial use only.

C
47
PURE GASES

METHYL CHLORIDE
TRANSPORTINFORMATION: FORMULA: CH3Cl
UN No. 1063
MSDS REFERENCE: 4622
CAS NO.: 74 -- 87 -- 3
GENERAL DESCRIPTION:

Shipping Name: Methyl Chloride Methyl Chloride Methyl Chloride Colorless, flammable, liquified gas with
an ethereal odor.
Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information

REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

MC 3.0 3.0 99.9 wt% FC 100 lb / 45.4 kg 300 SERIES : Non-corrosive


(liquid phase) FE 18 lb / 8.2 kg 200 SERIES : Non-corrosive
CH3OH < 50 ppmw
CH2Cl2 < 100 ppmw
H2O < 50 ppmw
Acidity < 10 ppmw
Residue < 10 ppmw

FC cylinder is available with eductor tube upon request.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
See our extensive line of safety products in
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg Section F.
FC / 660 59 / 407 195 / 88
FE / 660 59 / 407 40 / 18

C
48
PURE GASES

MONOMETHYLAMINE
TRANSPORTINFORMATION: FORMULA: CH3NH2
UN No. 1061
MSDS REFERENCE: 4626
CAS NO.: 74 -- 89 -- 5
GENERAL DESCRIPTION:
Methylamine, Methylamine, Methylamine,
Shipping Name: Anhydrous anhydrous Anhydrous Colorless, toxic, flammable, alkaline gas
with a fishy odor in lower concentra-
Hazard Class: 2.1 2.1 2.1
tions, and an ammoniacal odor in
Flammable Flammable Flammable higher concentrations.
Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

MA 2.0 2.0 99.0 % FX 125 lb / 56.7 kg 455 SERIES : Special Purpose


(liquid phase)

FX cylinders are equipped with a goose neck eductor tube.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
Contact your nearest specialty gases produc-
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg tion facility for technical information and
assistance.
FX / 240 / 705 29 / 200 205 / 93

C
49
PURE GASES

NATURAL GAS

TRANSPORTINFORMATION: FORMULA: N/A


UN No. 1971
MSDS REFERENCE: 4627
CAS NO.: 8006 -- 14 -- 2
GENERAL DESCRIPTION:
Natural Gas, Natural Gas, Natural Gas,
Shipping Name: Compressed compressed Compressed Colorless, flammable, high pressure gas
mixture of methane, ethane and
Hazard Class: 2.1 2.1 2.1
propane.
Flammable Flammable Flammable
Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

NG 0.85 0.85 85% Minimum T 381 / 10.6 200 SERIES : Non-corrosive


O2 + N2 Varies K 279 / 7.4
CnHm Varies
CH4 > 85%

Odorized with mercaptans.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
Use the convenient Praxair Fax to place orders
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg for your specialty gases and equipment.
T / 350 2400 / 16548 162 / 74 See our full line of hydrocarbon products in
K / 350 2000 / 13790 144 / 66
Section E - Petrochemical.
C
50
PURE GASES

NEON

TRANSPORTINFORMATION: FORMULA: Ne
UN No. 1065
MSDS REFERENCE: 4629
CAS NO.: 7440 -- 01 -- 9
GENERAL DESCRIPTION:
Neon, Neon Neon,
Shipping Name: Compressed Compressed Colorless, odorless, nonflammable,
inert gas.
Hazard Class: 2.2 2.2 2.2

Nonflammable Nonflammable Nonflammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

NE 5.0RS 5.0 99.999% T 7,500 L 400 SERIES : Non-corrosive


RESEARCH O2 < 1 ppm K 5,000 L
H2O < 1 ppm D4 300 L
N2 < 4 ppm C 100 L
Ar < 1 ppm RB 500 L
CO2 < 1 ppm
He < 4 ppm
THC < 0.5 ppm
H2 < 1 ppm

Other cylinder volumes from 5 liters to 7,500 liters are available

NE 4.83UH 4.83 99.9983% T 7,500 L 400 SERIES : Non-corrosive


ULTRA O2 < 3 ppm K 5,000 L
HIGH H2O < 1 ppm Q 1,500 L
PURITY N2 < 12 ppm
THC < 0.5 ppm

Other cylinder volumes from 5 liters to 7,500 liters are available.

Liquid Neon is available in 200 liter, 75 liter, and 30 liter dewars.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
Praxair, your global supplier.
STYLE / CGA psig / kPa, gauge lb / kg
Praxair, the leader in rare gas production and
T / 580 2371 / 16347 154 / 70
K / 580 1745 / 12031 142 / 55
application technology.
Q / 580 1545 / 10652 16 / 7
D4 / 580 1931 / 13314 10 / 5 For additional information regarding Praxair’s
C / 580 1675 / 11549 6 / 3 other laser gas products, see Section E - Laser.
RB / 580 1775 / 12238 6 / 3 C
51
PURE GASES

NITRIC OXIDE

TRANSPORTINFORMATION: FORMULA: NO
UN No. 1660
MSDS REFERENCE: 4632
CAS NO.: 10102 -- 43 -- 9
GENERAL DESCRIPTION:
Nitric Oxide, Nitric Oxide Nitric Oxide,
Shipping Name: Compresseed Compressed Colorless, highly toxic, oxidizing
gas with a slightly irritating odor.
Hazard Class: 2.3 2.3 (5.1) (8) 2.3

Toxic Gas, Toxic Gas, Toxic Gas,


Label: Oxidizer, Corrosive Oxidizing, Corrosive Oxidizer, Corrosive

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

NO 2.5 2.5 99.5% K 56 / 1.55 400 SERIES : Corrosive


H2O < 20 ppm Q 19 / 0.53
N2 < 3000 ppm
CO2 < 1000 ppm
N2O < 250 ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
Praxair, your global supplier.
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg
Use the convenient Praxair Fax to place orders
K / 660 500 / 3447 140 / 63 for your specialty gases and equipment.
Q / 660 500 / 3447 69 / 31

C
52
PURE GASES

NITROGEN
TRANSPORTINFORMATION: FORMULA: N2
UN No. 1066
MSDS REFERENCE: 4631
CAS NO.: 7727 -- 37 -- 9
GENERAL DESCRIPTION:
Nitrogen, Nitrogen Nitrogen,
Shipping Name: Compressed Compressed Colorless, odorless, nonflammable inert gas.

Hazard Class: 2.2 2.2 2.2

Nonflammable Nonflammable Nonflammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

NI 6.0RS 6.0 99.9999 % AT 250 / 6.93 400 SERIES : Non-corrosive


RESEARCH CH4 < 0.1 ppm AS 142 / 3.94
H2O < 0.2 ppm AQ 82 / 2.27
O2 < 0.5 ppm AG 20 / 0.55

NI 5.5CE 5.5 99.9995 % AS 142 / 3.94 400 SERIES : Non-corrosive


CONTINUOUS O2 < 0.5 ppm AQ 82 / 2.27
EMISSION H2O < 2 ppm A3 31 / 0.86
MONITORING CO2 < 1 ppm
ZERO CO < 0.5 ppm
THC < 0.05 ppm
NOX < 0.01 ppm
SO2 < 0.01 ppm

NI 5.5EC 5.5 99.9995 % AT 250 / 6.93 400 SERIES : Non-corrosive


ELECTRON H2O < 2 ppm T 304/ 8.43
CAPTURE O2 < 1 ppm K 228/ 6.32
DETECTOR* CO2 < 0.1 ppm
CO < 0.1 ppm
THC < 0.1 ppm

*The sum of O2, CO2, THC, as CH4, H2 and H20 < 6 ppm. No peaks exceed the equivalent of 50 ppt as Hexachloroethane; 10 ppb as Dodecane (C12).
A chromatogram of the halogen and hydrocarbon analysis is available with each cylinder.

NI 5.5TG 5.5 99.9995 % AT 250 / 6.93 400 SERIES : Non-corrosive


TRACE H2O < 2 ppm T 304/ 8.43
ANALYTICAL* O2 < 1 ppm K 228/ 6.32
CO2 < 0.1 ppm
CO < 1 ppm
THC < 0.1 ppm

*The sum of O2, CO2, THC, as CH4, H2 and H20 < 6 ppm. No peaks exceed the equivalent of 50 ppt as Hexachloroethane; 10 ppb as Dodecane (C12).
Batch analyzed.

C
53
PURE GASES

NITROGEN

Product and Package Information

REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

NI 5.0UM 5.0 99.999 % T 304 / 8.43 400 SERIES : Non-corrosive


ULTRA ZERO O2 < 2 ppm K 228 / 6.32 300 SERIES : Non-corrosive
AMBIENT H2O < 2 ppm Q 76 / 2.11
MONITORING CO2 < 0.5 ppm AS 142 / 3.94
CO < 0.1 ppm AQ 82 / 2.27
THC < 0.5 ppm A3 31 / 0.86
SO2 < 0.005 ppm
NOX < 0.02 ppm
SF6 < 0.001 ppm

NI 5.0VC 5.0 99.999 % AS 142 / 3.94 400 SERIES : Non-corrosive


VOLATILE O2 < 2 ppm AQ 82 / 2.27 300 SERIES : Non-corrosive
ORGANIC H2O < 2 ppm A3 31 / 0.86
COMPOUND CO2 < 0.3 ppm
FREE* CO < 0.01 ppm
THC < 0.05 ppm
SO2 < 0.01 ppm

*Individually analyzed for customer selected VOC component(s).

NI 5.0UH 5.0 99.999 % T 304 / 8.43 400 SERIES : Non-corrosive


ULTRA O2 < 1 ppm K 228 / 6.32 300 SERIES : Non-corrosive
HIGH H2O < 3 ppm
PURITY THC < 0.5 ppm
(Ar & Ne FREE BASIS)

NI 4.8VE 4.8 99.998 % T 304 / 8.43 300 SERIES : Non-corrosive


VEHICLE O2 < 0.5 ppm K 228 / 6.32 200 SERIES : Non-corrosive
EMISSION H2O < 1 ppm AS 142 / 3.94
ZERO* CO2 < 1 ppm** AQ 82 / 2.27
CO < 0.5 ppm A3 31 / 0.86
THC < 0.1 ppm
NOx < 0.1 ppm
*Complies with EPA I/M 240.
For BAR applications, please see page E14.
For alternative applications, other specifications may apply.
**Available with 315 - 385 ppm CO2 on request.

NI 4.8Z 4.8 99.998 % T 304 / 8.43 300 SERIES : Non-corrosive


ZERO THC < 0.5 ppm K 228 / 6.32 200 SERIES : Non-corrosive
Q 76 / 2.11

NI 4.8 4.8 99.998 % 6K 488 / 13.53 492 SERIES : Special Purpose


O2 < 5 ppm 4K 430 / 11.92 492 SERIES : Special Purpose
H2O < 3 ppm 3K 341 / 9.46 492 SERIES : Special Purpose
T 304 / 8.43 300 SERIES : Non-corrosive
K 228 / 6.32 200 SERIES : Non-corrosive
Q 76 / 2.11
F 11 / 0.31

NI 4.8OF 4.8 99.998 % T 304 / 8.43 300 SERIES : Non-corrosive


OXYGEN O2 < 0.5 ppm K 228 / 6.32 200 SERIES : Non-corrosive
C FREE
54
PURE GASES

NITROGEN

Product and Package Information

REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

NI 6.0SP 6.0 99.9999 % AT 250 / 6.93 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 0.2 ppm AS 142 / 3.94 400 SERIES : Non-corrosive
PROCESS H2O < 0.2 ppm
GAS CO2 < 0.1 ppm
CO < 0.1 ppm
THC < 0.1 ppm
H2 < 0.1 ppm

NI 5.5SP 5.5 99.9995 % AT 250 / 6.93 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 0.5 ppm AS 142 / 3.94 400 SERIES : Non-corrosive
PROCESS H2O < 0.5 ppm AQ 82 / 2.27
GAS CO2 < 0.5 ppm AG 20 / 0.55
CO < 1 ppm
THC < 0.5 ppm
H2 < 0.5 ppm

NI 5.0SP 5.0 99.999 % T 304 / 8.43 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 1 ppm K 228 / 6.32 400 SERIES : Non-corrosive
PROCESS H2O < 3 ppm 300 SERIES : Non-corrosive
GAS CO2 < 1 ppm
CO < 2 ppm
THC < 1 ppm
H2 < 2 ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information All product grade purities listed on Argon free basis.
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg For additional information on our semiconductor
6K / 677 6000 / 41400 340 / 154 process gases, see Section E - Semiconductor.
4K / 680 4500 / 31050 179 / 81
3K / 680 3500 / 24150 213 / 97 Praxair application specific zero gases are certified to
T / 580 2640 / 18202 165 / 75 meet your performance criteria. We analyze the
K / 580 2200 / 15168 149 / 68 relevant impurities to meet applicable EPA method
Q / 580 2200 / 15168 69 / 31 requirements.
F / 580 2200 / 15168 16 / 7
AT / 580 / 718 2200 / 15168 108 / 49 See Pg C77 for cryogenic liquid nitrogen.
AS / 580 / 718 2000 / 13790 60 / 27
AQ / 580 / 718 2200 / 15168 46 / 21 See Section E - Medical Gases for Nitrogen - N.F. Grade.
A3 / 580 2200 / 15168 20 / 9
AG / 580 / 718 2200 / 15168 13 / 6
C
55
PURE GASES

NITROGEN DIOXIDE

TRANSPORTINFORMATION: EMPIRICAL FORMULA: NO2


UN No. 1067 CHEMICAL FORMULA:

MSDS REFERENCE: 4633


CAS NO.: 10102 -- 44 -- 0
GENERAL DESCRIPTION:
Dinitrogen Tetroxide, Dinitrogen Tetroxide, Dinitrogen Tetroxide,
Shipping Name: Liquified liquified Liquified Redish-brown colored, highly toxic,
oxidizing gas with an irritating odor.
Hazard Class: 2.3 2.3 (5.1) 2.3

Toxic Gas, Toxic Gas, Toxic Gas,


Label: Oxidizer, Corrosive Oxidizing Oxidizer, Corrosive

Product and Package Information

PART No. PRODUCT QUALITY CYLINDER CONTENT EQUIPMENT RECOMMENDATIONS


GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 SEE REGULATOR REFERENCE GUIDE

NX 2.5 2.5 99.5 % K 120 lb / 54.6 kg 400 SERIES : Corrosive


(liquid phase)

Full length eductor tube available upon request.


Can be supplied with 100 psig nitrogen headspace pressure.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg
K / 660 0/0 252 / 115

56
PURE GASES

NITROGEN TRIFLUORIDE

TRANSPORTINFORMATION: FORMULA: NF3


UN No. 2451
MSDS REFERENCE: 4854
CAS NO.: 7783 -- 54 -- 2
Nitrogen Nitrogen Nitrogen
GENERAL DESCRIPTION:
Trifluoride, Trifluoride Trifluoride,
Shipping Name: Compressed Compressed Colorless, odorless, nonflammable,
corrosive, toxic gas.
Hazard Class: 2.2 2.3 (5.1) 2.3

Nonflammable Gas, Toxic Gas, Nonflammable Gas,


Label: Oxidizer Oxidizing Oxidizer

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

NF 4.0SP 4.0 99.99 % K 44 lb / 20 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 5 ppm K 20 lb / 9.1 kg 400 SERIES : Corrosive
PROCESS H2O < 1 ppm
GAS N2 < 5 ppm
CO2 < 3 ppm
N2O < 3 ppm
CF4 < 40 ppm
SF6 < 10 ppm
HF < 1 ppm

NF 2.7SP 2.7 99.7 % K 44 lb / 20 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 700 ppm K 20 lb / 9.1 kg 400 SERIES : Corrosive
PROCESS H2O < 1 ppm
GAS N2 < 700 ppm
CO2 < 25 ppm
N2O < 50 ppm
CF4 < 1500 ppm
SF6 < 50 ppm
HF < 0.3 ppm
CO < 25 ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
For additional information on our semiconductor
STYLE / CGA psig / kPa, gauge lb / kg process gases, see Section E - Semiconductor
K / 330 / 640 250 / 1724 179 / 81
K / 330 / 640 250 / 1724 155 / 70

C
57
PURE GASES

NITROUS OXIDE

TRANSPORTINFORMATION: FORMULA: N2O


UN No. 1070
MSDS REFERENCE: 4636
CAS NO.: 10024 -- 97 -- 2
GENERAL DESCRIPTION:

Shipping Name: Nitrous Oxide Nitrous Oxide Nitrous Oxide Colorless, oxidizing, liquified gas with a
slightly sweetish taste and odor.
2.2 2.2 (5.1) 2.2
Hazard Class:

Nonflammable Gas, Nonflammable Nonflammable Gas,


Label: Oxidizer Gas Oxidizer

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

NS 5.5 5.5 99.9995% K 64 lb / 29.0 kg 400 SERIES: Non-corrosive


O2 < 0.5 ppm
H2O < 1 ppm
N2 < 3 ppm
THC < 0.1 ppm
CO2 < 0.5 ppm
CO < 0.1 ppm
NH3 < 0.1 ppm
NO + NO2 < 0.2 ppm

NS 2.5AA 2.5 99.5% K 64 lb / 29.0 kg 308 SERIES : Special Purpose


ATOMIC ABSORPTION (liquid phase)

NS 5.5SP 5.5 99.9995% K 64 lb / 29.0 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 0.5 ppm AT 70 lb / 31.8 kg 400 SERIES : Non-corrosive
PROCESS H2O < 1 ppm AS 39 lb / 17.7 kg 308 SERIES : Special Purpose
GAS N2 < 3 ppm
THC < 0.1 ppm
CO2 < 0.5 ppm
CO < 0.1 ppm
NH3 < 0.1 ppm
NO2 < 0.1 ppm
NO < 0.1 ppm

NS 4.8SP 4.8 99.998% K 64 lb / 29.0 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 2 ppm AT 70 lb / 31.8 kg 400 SERIES : Non-corrosive
PROCESS H2O < 3 ppm AS 39 lb / 17.7 kg 308 SERIES : Special Purpose
GAS N2 < 8 ppm
THC < 1 ppm
CO2 < 2 ppm
CO < 1 ppm
NH3 < 1 ppm
NO2 < 1 ppm
NO < 1 ppm
For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information Praxair’s extensive distribution network ensures


CYLINDER PRESSURE GROSS WEIGHT on-time delivery.
STYLE / CGA psig / kPa, gauge lb / kg
AT / 326 / 712 745 / 5136 162 / 74 See Section E - Medical Gases for
AS / 326 / 712 745 / 5136 89 / 41 Nitrous Oxide - U.S.P. Grade.
K / 326 / 712 745 / 5136 175 / 80
Praxair, your full line supplier for specialty
gases and equipment.
C
58
PURE GASES

OXYGEN
TRANSPORTINFORMATION: FORMULA: O2
UN No. 1072
MSDS REFERENCE: 4638
CAS NO.: 7782 -- 44 -- 7
GENERAL DESCRIPTION:
Oxygen, Oxygen Oxygen,
Shipping Name: Compressed Compressed Colorless, odorless, highly oxidizing gas.

2.2 2.2 (5.1) 2.2


Hazard Class:
Nonflammable Gas, Nonflammable Nonflammable Gas,
Label: Oxidizer Gas Oxidizer

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

OX 5.0RS 5.0 99.999% T 337 / 9.35 300 SERIES : Non-corrosivee


RESEARCH H2O < 3 ppm K 249 / 6.90 200 SERIES : Non-corrosive
N2 < 1 ppm
THC < 0.1 ppm
CO2 < 1 ppm
CO < 1 ppm
Ar < 1 ppm
Kr < 1 ppm
Xe < 1 ppm
H2 < 0.1 ppm
He < 0.1 ppm

OX 4.3UH 4.3 99.993 % T 337 / 9.35 300 SERIES : Non-corrosive


ULTRA H2O < 3 ppm K 249 / 6.90 200 SERIES : Non-corrosive
HIGH N2 < 10 ppm
PURITY THC < 1 ppm
Ar < 40 ppm

OX 4.0HC 4.0 99.99 %* T 337 / 9.35 300 SERIES : Non-corrosive


HYDROCARBON THC < 0.1 ppm K 249 / 6.90 200 SERIES : Non-corrosive
FREE CO2 < 1 ppm

*Argon free basis.

OX 2.6Z 2.6 99.6 % T 337 / 9.35 300 SERIES : Non-corrosive


ZERO THC < 0.5 ppm K 249 / 6.90 200 SERIES : Non-corrosive

OX 2.6 2.6 99.6 % T 337 / 9.35 300 SERIES : Non-corrosive


H2O < 10 ppm K 249 / 6.90 200 SERIES : Non-corrosive
Q 83 / 2.30
F 16 / 0.44

C
59
PURE GASES

OXYGEN

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft / m
3 3
(SECTION F, PAGE 2)

OX 5.0SP 5.0 99.999 % AT 273 / 7.57 700 SERIES : Semiconductor


SEMICONDUCTOR H2O < 1 ppm AS 153 / 4.24 400 SERIES : Non-corrosive
PROCESS N2 < 5 ppm AQ 89 / 2.47
GAS THC < 0.5 ppm
CO2 < 1 ppm
CO < 1 ppm
Ar < 5 ppm
Kr < 3 ppm

OX 4.0SP 4.0 99.99 % T 337 / 9.35 700 SERIES : Semiconductor


SEMICONDUCTOR H2O < 3 ppm K 249 / 6.90 300 SERIES : Non-corrosive
PROCESS N2 < 50 ppm 200 SERIES : Non-corrosive
GAS THC < 1 ppm
CO + CO2 < 2 ppm
N2O < 2 ppm
Ar + Kr < 30 ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
See Section E - Medical Gases for
STYLE / CGA psig / kPa, gauge lb / kg Oxygen - U.S.P. Grade.
AT / 540 2200 / 15168 119 / 54 Praxair, your source for technical support.
AS / 540 2000 / 13790 63 / 29
AQ / 540 2200 / 15168 48 / 22 Special grades for laser applications are available,
T / 540 2640 / 18202 170 / 77 please inquire.
K / 540 2200 / 15168 153 / 70
Q / 540 2200 / 15168 72 / 33 See Pg C78 for cryogenic liquid oxygen.
F / 540 2200 / 15168 16 / 7
F / 540 463 / 3192 16 / 7 For additional information on our semiconductor
process gases, see Section E - Semiconductor.

C Bulk quantities available upon request.

60
PURE GASES

PHOSPHINE

TRANSPORTINFORMATION: FORMULA: PH3


UN No. 2199
MSDS REFERENCE: 4643
CAS NO.: 7803 -- 51 -- 2
GENERAL DESCRIPTION:

Shipping Name: Phosphine Phosphine Phosphine Colorless, highly toxic, flammable gas
with a disagreeable, garlic-like odor.
Hazard Class: 2.3 2.3 (2.1) 2.3

Toxic Gas, Toxic Gas, Toxic Gas,


Label: Flammable Gas Flammable Flammable Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

PH 5.7SP 5.7 99.9997% SS 17 lb / 7.7 kg 700 SERIES : Semiconductor


SEMICONDUCTOR Ar + O2 < 0.5 ppm 400 SERIES : Corrosive
PROCESS H2O < 1 ppm
GAS N2 < 1 ppm
C2 - C5 < 0.1 ppm
CO2 < 0.1 ppm
CO < 0.1 ppm
CH4 < 0.1 ppm
AsH3 < 0.1 ppm

PH 5.3SP 5.3 99.9993% EB 0.25 lb / 0.11 kg 700 SERIES : Semiconductor


SEMICONDUCTOR Ar + O2 < 1 ppm 400 SERIES : Corrosive
PROCESS H2O < 1 ppm
GAS N2 < 1 ppm
C2 - C5 < 1 ppm
CO2 < 1 ppm
CO < 1 ppm
CH4 < 1 ppm
AsH3 < 1 ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
See our full line of safety equipment and gas
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg cabinets in Section F.
SS / 350 / 632 593 / 4088 129 / 59
For additional information on our semiconductor
EB / 350 593 / 4088 6/3
process gases, see Section E - Semiconductor.
C
61
PURE GASES

PROPANE

TRANSPORTINFORMATION: FORMULA: C3H8


UN No. 1978
MSDS REFERENCE: 4646
CAS NO.: 74 -- 98 -- 6
GENERAL DESCRIPTION:

Shipping Name: Propane Propane Propane Colorless, flammable, liquified gas with
a natural gas odor.
Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

PR 4.0RS 4.0 99.99 wt% RB 200 g 400 SERIES : Non-corrosive


RESEARCH

Lot analysis supplied with each container.

PR 2.5IS 2.5 99.5 wt% FX 100 lb / 45.5 kg 300 SERIES : Non-corrosive


INSTRUMENT (liquid phase) FE 8 lb / 3.6 kg 200 SERIES : Non-corrosive
H2O < 3 ppm
Methane < 300 ppmw
Ethane < 600 ppmw
Propylene < 400 ppmw
n-Butane < 20 ppmw
Isobutane < 3000 ppmw
Sulfur < 1 ppmw

PR 2.0 2.0 99.0 wt% FX 100 lb / 45.5 kg 300 SERIES : Non-corrosive


(liquid phase) FE 8 lb / 3.6 kg 200 SERIES : Non-corrosive
H2O < 5 ppm
Methane < 500 ppmw
Ethane < 700 ppmw
Propylene < 600 ppmw
n-Butane < 100 ppmw
Isobutane < 4000 ppmw
Sulfur < 1 ppmw

FX and FE cylinders available with eductor tube upon request.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
See our full line of hydrocarbon products in
STYLE / CGA psig / kPa, gauge lb / kg Section E - Petrochemical.

FX / 510 109 / 752 174 / 79 Other cylinder sizes available, please inquire.
FE / 510 109 / 752 29 / 14
RB / 510 109 / 752 6/ 3
C
62
PURE GASES

PROPYLENE
TRANSPORTINFORMATION: FORMULA: C3H6
UN No. 1077
MSDS REFERENCE: 4648
CAS NO.: 115 -- 07 -- 1
GENERAL DESCRIPTION:

Shipping Name: Propylene Propylene Propylene Colorless, flammable, liquified gas with
a faintly sweet odor.
Hazard Class: 2.1 2.1 2.1

Flammable Flammable Flammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

PY 2.8RS 2.8 99.8 wt% RB 200 g 400 SERIES : Non-corrosive


RESEARCH (liquid phase)
H2O < 1 ppm
Oxygen < 2 ppmw
Carbon Dioxide < 1 ppmw
Carbon Monoxide < 1 ppmw
Methane < 1 ppmw
Ethane < 100 ppmw
Propane < 100 ppbw
Sulfur < 1 ppmw

Lot analysis supplied with each container

PY 2.5PL 2.5 99.5 wt% PX* 105 lb / 47.6 kg 400 SERIES : Non-corrosive
POLYMER (liquid phase) Q 13 lb / 5.90 kg
H2O < 3 ppm
Methane < 10 ppmw
Ethane < 50 ppmw
Propane < 3500 ppmw
n-Butane < 70 ppmw
Isobutane < 10 ppmw
Sulfur < 1 ppmw
*PX style cylinders available with eductor tube upon request.

PY 2.0 2.0 99.0 wt% PX* 105 lb / 47.6 kg 400 SERIES : Non-corrosive
(liquid phase) Q 13 lb / 5.90 kg 300 SERIES : Non-corrosive
H2O < 3 ppm
Methane < 20 ppmw
Ethane < 200 ppmw
Propane < 5000 ppmw
n-Butane < 200 ppmw
Isobutane < 20 ppmw
Sulfur < 1 ppmw
*PX style cylinders available with eductor tube upon request.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
See our full line of hydrocarbon products in
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg Section E - Petrochemical.
PX / 510 136 / 938 177 / 81
Praxair, your source for technical support.
Q / 510 136 / 938 78 / 36
RB / 510 136 / 938 6/3
C
63
PURE GASES

SILANE

TRANSPORTINFORMATION: EMPIRICAL FORMULA: SiH4


UN No. 2203 CHEMICAL FORMULA:

MSDS REFERENCE: 4649


CAS NO.: 7803 -- 62 -- 5
Silane, Silane Silane, GENERAL DESCRIPTION:

Shipping Name: Compressed Compressed Colorless, pyrophoric, flammable gas with a


repulsive odor.
2.1 2.1 2.1
Hazard Class:
Flammable Flammable Flammable
Label: Gas Gas Gas

Product and Package Information

PART No. PRODUCT QUALITY CYLINDER CONTENT EQUIPMENT RECOMMENDATIONS


GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 SEE REGULATOR REFERENCE GUIDE

SI 6.0SP 6.0 99.9999 % AT 5000 g 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 0.05 ppm SS 5000 g 400 SERIES : Corrosive
PROCESS H2O < 0.5 ppm 10000 g 455 SERIES : Special Purpose
GAS N2 < 1 ppm
CO2 < 0.05 ppm
CO < 0.05 ppm
Ar < 0.05 ppm
SiClx < 0.15 ppm
Si2H6 < 0.5 ppm
He < 1 ppm
H2 < 20 ppm
CH4 < 0.05 ppm
Resistivity >10,000 Ohm-cm
ppb/a - trace metals analysis are available

SI 5.0SP 5.0 99.999 % UK 13000 g 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 0.1 ppm UK 5000 g 400 SERIES : Corrosive
PROCESS H2O < 2 ppm AS 9000 g 455 SERIES : Special Purpose
GAS N2 < 2 ppm AS 5000 g
CO2 < 0.5 ppm
CO < 0.5 ppm
Ar < 0.5 ppm
SiClx < 0.5 ppm
He < 1 ppm
CH4 < 0.5 ppm
Resistivity > 7500 Ohm-cm
ppb/a – trace metals analysis are available

C
64
PURE GASES

SILANE
PART No. PRODUCT QUALITY CYLINDER CONTENT EQUIPMENT RECOMMENDATIONS
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 SEE REGULATOR REFERENCE GUIDE

SI 4.0SP 4.0 99.99 % T 10000 g 700 SERIES : Semiconductor


SEMICONDUCTOR O2 < 1 ppm K 5000 g 400 SERIES : Corrosive
PROCESS H2O < 3 ppm 455 SERIES : Special Purpose
GAS N2 < 20 ppm
CO2 < 1 ppm
CO < 1 ppm
Ar < 15 ppm
SiClx < 1 ppm
He < 30 ppm
H2 < 200 ppm
CH4 < 1 ppm
Resistivity > 5000 Ohm-cm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
For additional information on our semiconductor
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg process gases, see Section E - Semiconductor.
AT / 350 1040 / 7170 114 / 52
Other cylinder sizes available.
T / 350 1029 / 7095 167 / 76
UK / 350 1365 / 9067 164 / 74
UK / 350 780 / 5378 146 / 66
Praxair, high quality specialty gases and equip-
K / 350 780 / 5378 146 / 66 ment for your applications.
SS / 350 / 632 976 / 6729 123 / 56
AS / 632 1410 / 9721 70 / 32
AS / 350 945 / 6515 61 / 28 C
65
PURE GASES

SILICON TETRACHLORIDE
TRANSPORTINFORMATION: FORMULA: SiCl4
UN No. 1818
MSDS REFERENCE: 4824
CAS NO.: 10026 -- 04 -- 7
GENERAL DESCRIPTION:
Silicon Silicon Silicon
Shipping Name: Tetrachloride Tetrachloride Tetrachloride Colorless, highly toxic, nonflammable liquid
with a pungent odor.
Hazard Class: 8 8 8

Label: Corrosive Corrosive Corrosive

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

ST 4.0FO 4.0 99.99% ST-55 600 lb / 272 kg 400 SERIES : Corrosive


FIBER OPTIC HCl < 15 ppmw ST-10 100 lb / 45 kg
Trichlorosilane < 10 ppmw
Al < 25 ppbw
Fe < 50 ppmw
Other Metals(Ni, Cu, Cr, Mg) < 100 ppbw

ST 3.8SP 3.8 99.98 % ST-55 600 lb / 272 kg 700 SERIES : Semiconductor


SEMICONDUCTOR B < 0.2 ppbw ST-30 300 lb / 136 kg 400 SERIES : Corrosive
PROCESS C < 2 ppmw ST-10 100 lb / 45 kg
GAS Donor < 1 ppbw SB 110 lb / 50 kg
Resistivity > 100 Ohm-cm
other chlorosilanes < 0.06% w

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
For additional information on our semiconductor
STYLE / CGA psig / kPa, gauge lb / kg process gases, see Section E - Semiconductor.
ST-55 0 / 0 850 / 385
ST-30 0 / 0 450 / 204 Bulk quantities are available.
ST-10 0 / 0 150 / 68
C SB 0 / 0 142 / 65

66
PURE GASES

SILICON TETRAFLUORIDE
TRANSPORTINFORMATION: FORMULA: SiF4
UN No. 1859
MSDS REFERENCE: 4652
CAS NO.: 7783 -- 61 -- 1
Silicon Silicon Silicon
Tetraflouride, Tetraflouride, Tetraflouride, GENERAL DESCRIPTION:

Shipping Name: Compressed compressed Compressed Colorless, toxic, acidic gas with a
suffocating pungent odor. It is classified
Hazard Class: 2.3 2.3 2.3
as an Inhalation Hazard (Zone B) by
US DOT.
Label: Toxic Gas Toxic Gas Toxic Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

SV 2.0 4.0 99.99% G 9 lb / 4 kg 700 SERIES : Semiconductor


SEMICONDUCTOR Acidity(HF) < 50 ppm 400 SERIES : Corrosive
PROCESS As, P, B < 0.5 ppm 455 SERIES : Special Purpose
GAS CO2 < 1 ppm
CO < 1 ppm
CH4 < 10 ppm
N2 < 3 ppm
O2 + Ar < 1 ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information See our full line of safety equipment and gas
CYLINDER PRESSURE GROSS WEIGHT
cabinets in Section F.
STYLE / CGA psig / kPa, gauge lb / kg
G / 330 900 / 6205 38 / 17 For additional information on our semiconductor
process gases, see Section E - Semiconductor.

C
67
PURE GASES

SULFUR DIOXIDE
TRANSPORTINFORMATION: FORMULA: SO2
UN No. 1079
MSDS REFERENCE: 4655
CAS NO.: 7446 -- 09 -- 5
GENERAL DESCRIPTION:
Sulfur Dioxide, Sulphur Dioxide Sulfur Dioxide,
Shipping Name: Liquified Liquified Colorless, toxic, corrosive, nonflammable,
liquified gas with a sharp, pungent odor.
Hazard Class: 2.3 2.3 2.3

Toxic Gas, Toxic Gas Toxic Gas,


Label: Corrosive Corrosive

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

SD 3.8 3.8 99.98 % FC 150 lb / 68.0 kg 400 SERIES : Corrosive


(liquid phase) G 19 lb / 8.62 kg 408 SERIES : Special Purpose
H2O < 100 ppm
Residue < 75 ppmw
Acid as (H2SO4) < 25 ppmw

FC cylinder is available with eductor tube upon request.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
Praxair, high quality specialty gases and
STYLE / CGA psig / kPa, gauge lb / kg equipment for your applications.
FC / 660 34 / 234 205 / 94
G / 660 34 / 234 48 / 22

C
68
PURE GASES

SULFUR HEXAFLUORIDE
TRANSPORTINFORMATION: FORMULA: SF6
UN No. 1080
MSDS REFERENCE: 4657
CAS NO.: 2551 -- 62 -- 4
GENERAL DESCRIPTION:
Sulfur Sulphur Sulfur
Shipping Name: Hexafluoride Hexafluoride Hexafluoride Colorless, odorless, nonflammable,
liquified gas.
Hazard Class: 2.2 2.2 2.2

Nonflammable Nonflammable Nonflammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

SH 4.5RS 4.5 99.995% AS 70 lb / 38.1 kg 400 SERIES : Non-corrosive


RESEARCH RB 0.5 lb / 0.23 kg

Analysis supplied with each container.

SH 3.0 3.0 99.9% K 115 lb / 52.2 kg 300 SERIES : Non-corrosive


200 SERIES : Non-corrosive

SH 4.5SP 4.5 99.995% AS 70 lb / 38.1 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 + N2 < 50 ppm 300 SERIES : Non-corrosive
PROCESS H2O < 8 ppm 200 SERIES : Non-corrosive
GAS CF4 < 17 ppm
HF < 0.7 ppm

SH 2.8SP 2.8 99.8 % K 115 lb / 52.2 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 + N2 < 1500 ppm 300 SERIES : Non-corrosive
PROCESS H2O < 8 ppm 200 SERIES : Non-corrosive
GAS CF4 < 350 ppm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information Not for use in pneumatic retinopexy.


CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg
Contact your nearest specialty gases production
K / 590 / 716 320 / 2206 250 / 114 facility for technical information and assistance.
AS / 590 320 / 2206 120 / 55
RB / 590 320 / 2206 6/3 Praxair, your global supplier.
C
69
PURE GASES

TRICHLOROSILANE

TRANSPORTINFORMATION: FORMULA: SiHCl3


UN No. 1295
MSDS REFERENCE: 4823
CAS NO.: 10025 -- 78 -- 2
GENERAL DESCRIPTION:
Shipping Name: Trichlorosilane Trichlorosilane Trichlorosilane
Colorless, corrosive, flammable liquid with an
Hazard Class: 4.3 4.3 (3) (8) 4.3 irritating, choking odor.
Label: Dangerous When Wet, Dangerous When Wet, Dangerous When Wet,
Flammable Liquid, Flammable Liquid, Flammable Liquid,
Corrosive Corrosive Corrosive

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

TC 3.0SP 3.0 99.9 % ST-55 550 lb / 249.5 kg 700 SERIES : Semiconductor


SEMICONDUCTOR B < 0.1 ppbw ST-30 275 lb / 124.7 kg 400 SERIES : Corrosive
PROCESS C < 50 ppmw ST-10 90 lb / 40.8 kg
GAS P < 1 ppbw SB 99 lb / 44.9 kg
Resistivity > 200 Ohm-cm

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information For additional information on our semiconductor


CYLINDER PRESSURE GROSS WEIGHT process gases, see Section E - Semiconductor.
STYLE / CGA psig / kPa, gauge lb / kg
ST-55 / -- 2.0 / 138 800 / 363
Bulk quantities are available.
ST-30 / -- 2.0 / 138 425 / 193
Praxair, high quality specialty gases and equip-
ST-10 / -- 2.0 / 138 140 / 64
ment for your applications.
C SB / 678 2.0 / 138 141 / 64

70
PURE GASES

TRIMETHYLAMINE
TRANSPORTINFORMATION: FORMULA: (CH3)3N
UN No. 1083
MSDS REFERENCE: 4662
CAS NO.: 75 -- 50 -- 3
GENERAL DESCRIPTION:
Trimethylamine, Trimethylamine, Trimethylamine,
Shipping Name: Anhydrous anhydrous Anhydrous Colorless, toxic, flammable, alkaline gas with
a fishy odor in lower concentrations, and an
Hazard Class: 2.1 2.1 2.1
ammonical odor in higher concentrations.

Label: Flammable Gas Flammable Gas Flammable Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

TA 2.0 2.0 99.0 % FX 125 lb / 56.7 kg 455 SERIES : Special Purpose


(liquid phase)

FX cylinders are equipped with a goose neck eductor tube.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
CYLINDER PRESSURE GROSS WEIGHT
See our full line of safety equipment and gas
STYLE / CGA psig / kPa, gauge lb / kg cabinets in Section F.
FX / 240 / 705 13.3 / 92 205 / 93

C
71
PURE GASES

TUNGSTEN HEXAFLUORIDE
TRANSPORTINFORMATION: FORMULA: WF6
UN No. 2196
MSDS REFERENCE: 4855
CAS NO.: 7783 -- 82 -- 6
Tungsten Tungsten Tungsten GENERAL DESCRIPTION:

Shipping Name: Hexafluoride Hexafluoride Hexafluoride Light-yellow colored, odorless, toxic,


liquified gas.
Hazard Class: 2.3 2.3 2.3

Toxic Gas, Toxic Gas Toxic Gas,


Label: Corrosive Corrosive

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

WF 5.0SP 5.0 99.999 % 44 lb / 20 kg 700 SERIES : Semiconductor


SEMICONDUCTOR O2 + Ar < 1 ppm 22 lb / 10 kg 455 SERIES : Special Purpose
PROCESS N2 < 1 ppm
GAS CO2 < 1 ppm
CO < 1 ppm
CF4 < 1 ppm
HF < 10 ppm
SF6 < 0.5 ppm
SiCl4 < 0.5 ppm

Product shipped in nickel cylinders.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
For additional information on our semiconductor
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg
process gases, see Section E - Semiconductor.
-- / 670 2.6 / 18 111 / 51 Praxair, your source for technical support.
-- / 670 2.6 / 18 31/ 15

C
72
PURE GASES

XENON

TRANSPORTINFORMATION: FORMULA: Xe
UN No. 2036
MSDS REFERENCE: 4677
CAS NO.: 7440 -- 63 -- 3
GENERAL DESCRIPTION:
Xenon, Xenon Xenon,
Shipping Name: Compressed Compressed Colorless, odorless, nonflammable,
inert gas.
Hazard Class: 2.2 2.2 2.2

Nonflammable Nonflammable Nonflammable


Label: Gas Gas Gas

Product and Package Information


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY/SPECIFICATION STYLE ft3 / m3 (SECTION F, PAGE 2)

XE 5.0RS 5.0 99.999 % K 5,000 L 400 SERIES : Non-corrosive


RESEARCH O2 < 1 ppm Q 1,000 L
H2O < 2 ppm D4 300 L
CO2 < 1 ppm D4 100 L
THC < 1 ppm RB 50 L
N2 < 5 ppm
H2 < 1 ppm
Ar < 1 ppm
Kr < 3 ppm

Other cylinder volumes from 5 liters to 10,000 liters are available.

For ordering purposes, please add the desired cylinder style to the end of the above part number. SEE SECTIONS G AND H FOR SAFETY AND TECHNICAL INFORMATION.

Cylinder Information
Praxair, the leader in rare gas production and
CYLINDER PRESSURE GROSS WEIGHT
STYLE / CGA psig / kPa, gauge lb / kg application technology.
K / 580 836 / 5764 195 / 90
Q / 580 655 / 4516 77 / 35 For additional information regarding Praxair’s
D4 / 580 858 / 5916 10 / 5 other laser gas products, see Section E - Laser.
D4 / 580 470 / 3240 10 / 5
RB / 580 842 / 5805 6/ 3 C
73
PURE GASES

CRYOGENIC LIQUIDS

TRANSPORTINFORMATION: ARGON
UN No. 1951 FORMULA: Ar

MSDS REFERENCE: 4564


CAS NO.: 7440 -- 37 -- 1
Argon, Argon, Argon,
Shipping Name: GENERAL DESCRIPTION:
Refrigerated Liquid refrigerated liquid Refrigerated Liquid
Colorless, odorless, nonflammable
Hazard Class: 2.2 2.2 2.2 cryogenic liquid.
Nonflammable Nonflammable Nonflammable
Label: Gas Gas Gas

Product and Package Information

RELIEF VALVE REGULATOR RECOMMENDATIONS


PART No. PRODUCT CONNECTION CONTAINER CONTENT GROSS WEIGHT SETTING SEE REFERENCE GUIDE
SPECIFICATIONS CGA STYLE ft / m
3 3
lb / kg psig / kPa (SECTION F, PAGE 2)

AR 4.8IC ICP GAS - 580 160 L 4460 / 126 714 / 324 230 / 1586 206 SERIES : Special Purpose
99.998 % LIQ - 295 180 L 4960 / 140 773 / 351 230 / 1586
O2 < 3 ppm 230 L 6080 / 172 928 / 421 230 / 1586
CO2 < 1 ppm 265 L 6990 / 198 1042 / 473 230 / 1586
THC < 1ppm
N2 < 10 ppm
H2 < 1 ppm
H2O < 2 ppm

AR 4.8LS LASER GAS - 580 200 L 4720 / 134 864 / 393 400 / 2758 206 SERIES : Special Purpose
99.998 % LIQ - 295 230 L 5770 / 163 937 / 426 350 / 2413
265 L 6640 / 188 1006 / 457 350 / 2413
600 L -- -- --

Contact your Praxair representative on the availability of other container sizes.

C
74
PURE GASES

CRYOGENIC LIQUIDS
TRANSPORTINFORMATION: CARBON DIOXIDE
UN No. 2187 FORMULA::
FORMULA CO2

MSDS REFERENCE
MSDS REFERENCE:: 4573
CAS N
CAS NO .:
O.: 124 -- 38 -- 9
Carbon Dioxide, Carbon Dioxide, Carbon Dioxide,
Refrigerated Liquid refrigerated liquid Refrigerated Liquid GENERAL DESCRIPTION::
GENERAL DESCRIPTION
Shipping Name:
Colorless, odorless, nonflammable, slightly
Hazard Class: 2.2 2.2 2.2 acidic, refrigerated liquid.

Nonflammable Nonflammable Nonflammable


Label: Gas Gas Gas

Product and Package Information

RELIEF VALVE REGULATOR RECOMMENDATIONS


PART No. PRODUCT CONNECTION CONTAINER CONTENT GROSS WEIGHT SETTING SEE REFERENCE GUIDE
SPECIFICATIONS CGA STYLE ft / m
3 3
lb / kg psig / kPa (SECTION F, PAGE 2)

CD M U.S.P. ≥ 99.0 %* GAS - 320 180 L 400 lb/182 kg 730 / 331 350 / 2413 206 SERIES : Special Purpose
H2S < 1 ppm LIQ - 320 308 SERIES : Special Purpose
CO < 10 ppm
NO < 2.5 ppm
NH3 < 25 ppm
SO2 < 5 ppm
H2O < 200 ppm
NO2 < 2.5 ppm

*Dewar quantities of laser grade available.

C
75
PURE GASES

CRYOGENIC LIQUIDS

TRANSPORTINFORMATION: HELIUM
UN No. 1963 FORMULA: He

MSDS REFERENCE: 4600


CAS NO.: 7440 -- 59 -- 7
Helium, Helium, Helium,
Shipping Name: GENERAL DESCRIPTION:
Refrigerated Liquid refrigerated liquid Refrigerated Liquid
Colorless, odorless, nonflammable cryogenic
Hazard Class: 2.2 2.2 2.2 liquid and gas.

Nonflammable Nonflammable Nonflammable


Label: Gas Gas Gas

Product and Package Information

CONTENT RELIEF VALVE REGULATOR RECOMMENDATIONS


PART No. PRODUCT CONNECTION CONTAINER LIQUID
CONTENT GROSS WEIGHT SETTING SEE REFERENCE GUIDE
SPECIFICATIONS CGA STYLE nom
3
@mnbp
ft / 3
lb / kg psig / kPa (SECTION F, PAGE 2)

HE 5.0 99.999 % Coupling for CMSH-30 30 L 129 / 59 1 / 6.89 N/A


O2 < 1 ppm 3/8 in or CMSH-60 60 L 209 / 95 1 / 6.89
H2O < 2 ppm 1/2 in CMSH-100 100 L 249 / 113 1 / 6.89
CO2 < 1 ppm transfer tube
CO < 1 ppm
THC < 0.1 ppm
N2 < 5 ppm Coupling for CMSH-250 250 L 526 / 239 1 / 6.89 N/A
H2 < 1 ppm 5/8 in or CMSH-500 500 L 824 / 374 1 / 6.89
Ne < 2 ppm 3/4 in
transfer tube

* All liquid helium containers are of non-magnetic, stainless steel construction.

* CMSH-250 and CMSH-500 containers have electric automatic pressure building units.

C
76
PURE GASES

CRYOGENIC LIQUIDS
TRANSPORTINFORMATION: NITROGEN
UN No. 1977 FORMULA: N2

MSDS REFERENCE: 4630


CAS NO.: 7727 -- 37 -- 9
Nitrogen, Nitrogen, Nitrogen,
Shipping Name: Refrigerated Liquid refrigerated liquid Refrigerated Liquid GENERAL DESCRIPTION:
Colorless, odorless, nonflammable
Hazard Class: 2.2 2.2 2.2 cryogenic liquid.
Nonflammable Nonflammable Nonflammable
Label: Gas Gas Gas

Product and Package Information

RELIEF VALVE REGULATOR RECOMMENDATIONS


PART No. PRODUCT CONNECTION CONTAINER CONTENT GROSS WEIGHT SETTING SEE REFERENCE GUIDE
SPECIFICATIONS CGA STYLE ft / m
3 3
lb / kg psig / kPa (SECTION F, PAGE 2)

NI 5.0M N.F. UHP GAS - 580 160 L 3690 / 102 517 / 235 230 / 1586 206 SERIES : Special Purpose
99.999 % LIQ - 295 180 L 4110 / 114 557 / 253 230 / 1586
Odor - None 230 L 5030 / 139 664 / 301 230 / 1586

NI 2.0M N.F. -- 99.0 % GAS - 580 160 L 3690 / 102 517 / 235 230 / 1586 206 SERIES : Special Purpose
CO < 10 ppm LIQ - 295 180 L 4110 / 114 557 / 253 230 / 1586
Odor - None 230 L 5030 / 139 664 / 301 230 / 1586

NI 4.8LS LASER GAS - 580 200 L 3680 / 102 645 / 293 400 / 2758 206 SERIES : Special Purpose
99.998 % LIQ - 295 230 L 4740 / 131 683 / 310 350 / 2413
265 L 5450 / 151 755 / 343 350 / 2413
600 L Please inquire.

Contact your Praxair representative on the availability of other container sizes.

C
77
PURE GASES

CRYOGENIC LIQUIDS

TRANSPORTINFORMATION: OXYGEN
UN No. 1073 FORMULA: O2

MSDS REFERENCE: 4637


CAS NO.: 7782 -- 44 -- 7
Oxygen, Oxygen, Oxygen,
Refrigerated Liquid refrigerated liquid Refrigerated Liquid GENERAL DESCRIPTION:
Shipping Name:
Odorless, highly oxidizing, light blue cryogenic
Hazard Class: 2.2 2.2 (5.1) 2.2 liquid.
Nonflammable Oxidizing Gas Nonflammable
Label: Gas, Oxidizer Gas, Oxidizer

Product and Package Information

RELIEF VALVE REGULATOR RECOMMENDATIONS


PART No. PRODUCT CONNECTION CONTAINER CONTENT GROSS WEIGHT SETTING SEE REFERENCE GUIDE
SPECIFICATIONS CGA STYLE ft / m
3 3
lb / kg psig / kPa (SECTION F, PAGE 2)

OX 2.0M U.S.P. ≥ 99.0 % GAS - 540 160 L 4580 / 127 629 / 285 230 / 1586 206 SERIES : Special Purpose
CO < 10 ppm LIQ - 440
CO2 < 300 ppm
Odor -- None

OX 2.5LS LASER GAS - 540 200 L 4890 / 136 775 / 352 400 / 2758 206 SERIES : Special Purpose
99.5 % LIQ - 440 230 L 5930 / 164 831 / 378 350 / 2413
265 L 6820 / 189 923 / 420 350 / 2413
600 L Please inquire

Contact your Praxair representative on the availability of other container sizes.

C
78
PURE GASES

BULK PRODUCTS

Praxair is one of the largest industrial gas Air


suppliers worldwide. We’ve achieved this
industry-leading position by focusing on
our customers, for whom we supply Argon - Ar
atmospheric, process, specialty and life
support gases. Praxair also is an industry
leader in delivery options and support Carbon Monoxide - CO
services for customers.

Praxair can supply multi-cylinder cluster


Carbon Dioxide - CO2
units, tube trailers, cryogenic containers
or bulk cryogenic and atmospheric Ethane - C2H6
tankage to serve your every need.

Our range of products is equaled only by Ethylene - C2H4


the variety of services we provide. For
example, before we recommend a supply
option, our professionals will analyze Helium - He
your operation with you to determine your
gas supply requirements and critical
factors, including: Hydrogen - H2
• Volumes
• Pressure
Methane - CH4
• Planned utilization
• Power availability and costs Mixtures
• Purity
• Usage patterns
• Siting needs Natural Gas
Using this information, we can recom-
mend the total gas supply system that will Neon - Ne
provide the gas you need at the lowest
cost of ownership and highest reliability.
Nitrogen - N2

Nitrous Oxide - N2O

Oxygen - O2

Silane - SiH4

= BULK LIQUID TRAILER AVAILABLE

= GASEOUS TUBE TRAILER AVAILABLE

C
79
PURE GASES

C
80
MIXTURES
D
MIXTURES In this section . . .

■ More than 500 minor components

■ Consistent, reproducible,
guaranteed products

■ The right grades for the right


applications

■ Performance based certification

■ Stringent SPC-QA/QC programs


Certification Documents
■ Five Research and Development
Available
Centers

Certificate of Compliance (COC1)


Document that indicates that a product meets
or exceeds the minimum purity or analytical
accuracy as specified in the Specialty Gas
Catalog
Certificate of Conformance (COC2)
Statement of guarantee that the product from
a specific batch conforms to the components,
minimum purity and maximum impurity specifi-
cations as listed in the Specialty Gas Catalog
Certificate of Analysis (COA)
A document that reports the actual analytical
test results for pure product or for a calibration
mixture. Either single cylinder or batch analysis
certification is available.

Available Upon Request!


MIXTURES

MIXTURE SELECTION GUIDE

Praxair offers flexibility in supplying To simplify the ordering process


customized gas mixtures for medical, Praxair has detailed the most common
industrial and scientific applications. and popular mixtures in the “Gases
Praxair is committed to safely produc- for Special Applications” section E,
ing STABLE, ACCURATE mixtures. We which is the next section of this cata-
produce mixtures from two to in excess log. For your ordering convenience,
of 40 components and apply all safety please refer to the following summary
and quality considerations learned of common mixtures offered in
through decades of experience in mix- section E.
ture production. This section will
guide you through the mixture selec-
tion process.

MIXTURE SELECTION GUIDE - SUMMARY OF MIXTURES IN SECTION E


Application Product Page Application Product Page

Instrumentation Electron Capture Detector Mixtures E2, E5 Petrochemical Natural Gas Reference Standards E18
- P-5, 5% CH4 in Ar ASTM Test Mixtures E18
- P-10, 10% CH4 in Ar BTU Certified Mixtures E18
Flame Ionization Detector Mixtures E4, E5 GPA Standard Mixtures E18
- 40% H2 in He Petroleum Liquid Mixtures E18
- 40% H2 in N2 Petrochemical Gaseous Mixtures E18
Thermal Conductivity Detector Mixtures E5 Petrochemical Liquified Mixtures E19
- 8.5% H2 in He
Arc or Spark Emission E4, E5
- 5% H2 in Ar Industrial Hygiene Praxair Portable Series-Refillable E22
XRF (Fluorescence X) Mixtures E4, E5 - 25% and 50% LEL C1-C4 Mixtures
- P-10, 10% CH4 in Ar - CO in Air or N2
- 1.3% n-C4H10 in He - O2 Deficiency Mixtures
- 0.95% i-C4H10 in He - Zero Gases
- 1.5% C3H8 in He
Non-Dispersive Infrared (NDIR) Analyzer Mixtures Praxair Portable Series-Non-Refillable E20, E21
- Carbon Dioxide Calibration Mixtures D6 - CO2 in N2
- Carbon Monoxide Calibration Mixtures D6 - CO in Air or N2
- Nitric Oxide Calibration Mixtures D6 - CO, CH4, O2 in N2
- Sulfur Dioxide Calibration Mixtures D6 - C6H14 in Air or N2
Nuclear Counting E5 - H2 in Air
- P-5, 5% CH4 in Ar - i-C4H8 in Air
- P-10, 10% CH4 in Ar - CH4 in Air
- 10% CO2 in Ar - C3H8 in Air
- 1.3% n-C4H10 in He - N2O in Air
- 0.95% i-C4H10 in He - O2 Deficiency Mixtures
Oxygen Analyzer Mixtures D6 - Zero Gases
- Oxygen Calibration Mixtures - NH3 in Air or N2
Chemiluminescence Mixtures D6 - SO2 in Air or N2
- NOx Mixtures - NO in N2
- NO2 in N2
Environmental NIST Traceable Reference Materials - H2S in Air or N2
(NTRM) & Research Gas Materials (RGM) E10 - H2S, C3H8 in Air
EPA Protocols E11, 12 - H2S, C3H8, O2 in N2
Environmental Mixtures - H2S, C5H12, O2 in N2
(other mixture grades) E13 - H2S, C5H12, in Air
Mobile Source Gases E14 - H2S, CH4, CO in Air
I/M Standards E14
Supercritical Fluid Products E15
VOC Standards E16 D
1
MIXTURES

MIXTURE SELECTION GUIDE

Application Product Page Application Product Page

Lasers Flow-Through Carbon Dioxide Laser E23-E25 Biotechnology Anaerobic Incubation Mixtures E32
Coherent General CorporationTM (continued) - 5% CO2/N2
Lumonics LaserMark® 1,2,3 and 4 - 10% CO2/N2
Laser TechnicsTM - 5% CO2, 5% H2/N2
Laser ElectronicsTM - 5% CO2, 10% H2/N2
Sealed Tube Laser Mixtures - 10% CO2, 10% H2/N2
Excimer Laser Mixtures
Fluorine Excimer Laser Mixtures Sterilization
Excimer Mixtures Containing Hydrogen Chloride Gases Oxyfume® 2000 and Oxyfume® 2002 E33-E34
MedifumeTM
Healthcare Therapy Gases E29 Carboxide®
- General Medical Mixtures Oxyfume® 20
- Heliox
Diagnostic Gases E29-E30 Food Extendapak® Gases E35-E37
- XeScanTM Contrast Enhancement Agent - Beer Gas
- Lung Diffusion for Pulmonary Function Studies - Banana Gas 32TM
- Blood Gas Analysis
- Biological Incubation Atmospheres Semiconductor Silicon - Precursor Gases E38-E40
- Medical Laser Gas Mixtures Dopant Gases
Etchant Gases
Biotechnology Aerobic Incubation Mixtures E32 Atmospheric/Purge
- 5% CO2/O2 Cylinder Gases
- 10% CO2/O2 Reactant Gases
- 5% CO2, 5% O2/N2
- 5% CO2, 10% O2/N2
- 2.5% CO2, 21% O2/N2
- 5% CO2, 21% O2/N2
- 10% CO2, 21% O2/N2
- 15% CO2, 21% O2/N2

COMMONLY USED CYLINDERS FOR MIXTURES

CYLINDER SIZES

Non-Reactive K

Reactive AS

FX
Liquid Blends
FE
Piston Cylinder (1000cc)

See Section B for the other cylinder options.

D
2
MIXTURES

BEHIND THE SCENES

Safe, Accurate, Consistent, For low concentration or highly reactive ■ Analytical Instrumentation
components we use our additional, propri- - Gas Chromatography (GC detectors-,
Reliable....Every Time
etary cylinder treatment processes. With the TCD, FID, ECD, HID, DID, FPD, PID,
application of these unique cylinder prepa- NPD, RGA)
Our sophisticated mixture blending ration processes, we are able to produce - Chemiluminescence
software and communication pro- accurate part per billion and low part per - Fourier Transform Infrared (FTIR)
grams (worldwide databases with million concentration reactive gas mixtures - Atomic Absorption (GFAA)
international access) provide the very with guaranteed stabilities. - Mass Spectroscopy (MS)
- Fluorescence UV
latest in mixture technology for our
■ Blending Systems - Process Instrumentation (NDIR, O2,
customers. Praxair prepares mixtures utilizing high THC, H2O)
load, high sensitivity Gravimetric Balances,
■ Component Raw Material Micro Balance Capillary Injection, ■ Reference Materials
All blending source gases and liquids are Computerized Dynamic Blending Systems - Standard Reference Materials (SRM)
qualified to ensure that they are appropriate and Volumetric Manifolds. In every case - NIST Traceable Reference Materials
for your application. We have determined we use the method best suited to your (NTRM)
through experience that certain impurities application. - Gas Manufacturer’s Intermediate
affect the performance or stability of the Standards (GMIS)
final mixture. All gravimetric balances are calibrated - Praxair Primary Laboratory Standards
with NIST traceable weights. All balances, (PPLS)
We have developed and used special pro- gauges and process instruments undergo
prietary purification techniques for the specified periodic maintenance and ■ Ongoing Inter-Laboratory Quality
removal of critical impurities. Upon request calibration.
Assurance Evaluation Programs
a complete impurity profile or specific impu- - Performed Quarterly
rity analyses can be provided. ■ Mixture Homogenization
Once a particular mixture is prepared,
■ Cylinder Preparation mechanical rolling, gas turbulence or molec-
Praxair utilizes a series of computer con- ular agitation is used to ensure the homo-
trolled heating, vacuum and purge cycles to geneity of the final mixture.
prepare both aluminum and steel cylinders.

Praxair's 17 North American Manufacturing And Documentation


Specialty Gas Facilities are staffed Quality Control Certification:
with Chemists and Engineers trained Certificate of Compliance (COC1)
in the preparation and analytical cer- Producing quality gas mixtures begins with Document that delineates that a product
tification of Specialty Gas mixtures. proper cylinder selection and preparation to meets or exceeds the minimum purity or ana-
lytical accuracy as specified.
ensure high quality and enhanced stability.
Outlets are selected according to Certificate of Conformance (COC2)
Praxair's sales and technical support
Compressed Gas Association (CGA) guide- Statement of guarantee that the product from
team will assist you in determining a specific batch conforms to the compo-
lines.
and specifying all your specialty needs nents, minimum purity and maximum impuri-
including: high purity gases, calibra- ty specifications as listed.
The manufacture and certification of all
tion mixtures and correct delivery Certificate of Analysis (COA)
Praxair specialty gases are documented in a
A document that reports the actual analytical
equipment. comprehensive quality assurance manual. test results for pure product or for a calibra-
Where appropriate, traceability will be tion mixture. Either single cylinder or batch
established to Praxair Primary Laboratory analysis certification is available.
Standards or to NIST Traceable Standards.
All processes, procedures, analytical meth- Available Upon Request!
Ask About Our ods and reports are carefully documented,
ISO Certified Specialty controlled and internally audited by Praxair
Gas Plants. Q.C. / Q.A. Officers.
D
3
MIXTURES

BEHIND THE SCENES

MIXTURE -- SAFETY AND QUALITY


Safety and quality considerations limit the ■ Vapor Pressure to safety and the potential by-products creat-
mixtures we can offer -- among these are: Vapor restricted mixtures are evaluated via ed by a chemical reaction; then integrity of
a state of the art computer modeling pro- analytical accuracy is evaluated. A feasibili-
■ Fuel - Oxidizer Mixtures gram. Mixtures containing low vapor pres- ty review is performed prior to any mixture
Praxair will prepare mixtures containing sure components are frequently made at preparation. Where applicable, Praxair
flammable and oxidizing components only reduced pressures. Pressure reduction helps will provide aluminum or specially treated
after a complete safety review. Each mixture prevent condensation of less volatile compo- cylinders for low concentration reactive gas
is evaluated to ensure the flammable concen- nents to ensure mixture homogeneity. mixtures. See Section 2 for details on alu-
tration is well below the flammable limits. Where applicable, Praxair will recommend minum, stainless steel and specially treated
Praxair will determine if the mixture must be a low pressure cylinder to maximize the vol- cylinders.
made at reduced pressure. Final mixture ume of mixture contents. See Section 2 for The stability of certain gas mixtures can
pressures are based on BTU calculations. details on low pressure cylinders. be affected by the length of time they are
stored, as well as the storage temperature.
■ Reactive Gas Mixtures To ensure the integrity of gas mixtures, stor-
We assess mixture stability to make sure the age time and temperature for susceptible
requested mixture does not contain compon- mixtures should be monitored.
ents that may react with each other or with
the cylinder. Primary consideration is given

MIXTURE GRADES AND SPECIFICATIONS


Praxair mixtures are grouped into two Our Standard grades are analyzed stan- requirements. Praxair produces two addi-
basic categories, general and environmen- dards used for high volume applications tional grades within the Environmental
tal. Within the general category Praxair where the blending precision and accuracy Category, NTRM and EPA Protocols .
certifies mixtures to two grades, Masters of the Master grade is not required. These
and Standard. If you have applications mixtures are prepared by either gravimetric, WE WOULD BE PLEASED TO PROVIDE
which require other grades of mixtures, volumetric or partial pressure methods. GRADE RECOMMENDATIONS BASED
please contact your nearest Praxair repre- Primary, Dynamic-Blend, and Certified ON YOUR SPECIFIC APPLICATION.
sentative. grades are available. As in the Master CALL YOUR PRAXAIR REPRESENTA-
grades, the minor component(s) are ana- TIVE OR YOUR NEAREST CUSTOMER
Our Master grades provide the highest lyzed and certified by Praxair. The economi- SERVICE LOCATION FOR ASSIS-
degree of accuracy and confidence for your cal Non-Certified grade is also suitable for TANCE!!
most demanding applications. These mix- applications which do not require an analyt-
tures are prepared gravimetrically on elec- ical certification.
tronic high precision balances or with state-
of-the-art dynamic blenders. The accuracy Our Environmental Grades have been
from these methods generally exceed the developed to meet the stringent requirements
accuracy of most analytical instruments. of specific environmental applications such
Praxair produces two grades within the as EPA Protocols, Inspection and Mainten-
Master category; Primary, Dynamic-Blend. ance Emission standards, and mixtures
The minor component(s) are analyzed and requiring NIST Traceability. Specifications
certified by Praxair. have been developed to meet industry stan-
dards or in some cases to meet regulatory

D
4
MIXTURES

Grade Specifications

■ Primary Master – High accuracy Mixture Mixture Component Blnd. Prep. Laboratory Analytical
mixtures prepared gravimetrically on Grade Concentration Range Tolerance Accuracy
electronic high precision balance. These
Environmental Grades
standards are analyzed and named
against NIST SRM’s or NTRMs. NTRM1 N/A N/A ≤ 1%
■ Primary Standard – High accuracy EPA Protocol 1 2 ppm - 25 ppm ± 10% ± 1% NIST Traceable
mixtures prepared gravimetrically on 25.1 ppm - 24% ± 5% ± 1% NIST Traceable
electronic high precision balance. These Benchmark See Standard Grade
standards are analyzed against Praxair Standard2 section below
Primary Laboratory Standards (PPLS) Primary Master/ See Master Grade
and named to a gravimetrically generated Dynamic Blend section below
concentration. Master
■ Dynamic-Blend Master – These zero Certified See Standard Grade
blend tolerance mixtures are prepared on Standard section below
an instrument based dynamic blending Micro Blend 500 ppb - 999 ppb ± 15% ± 15%
system. These masters are analyzed and
named against NIST SRM and NTRMs. Certified Master Grade
Batches of cylinders from two to one Certified Master 1 ppm - 99 ppm ± 20% ± 5% NIST Traceable
hundred can be produced with the 100 ppm - 999 ppm ± 10% ± 2% NIST Traceable
identical concentrations. 1.0% - 49.9% ± 5% ± 1% NIST Traceable
■ Dynamic-Blend Standard –
Master Grades
These mixtures are prepared similarly to
the Dynamic Blend Master. Certification Primary Master1 1 ppm - 9.9 ppm ± 10% ± 0.1 ppm
of the mixtures is based on process 10 ppm - 9999 ppm ± 5% ± 1%
accuracy and Praxair Primary Laboratory 1.0% - 49% ± 2% ± 1% or 0.02% absolute
Standards (PPLS). whichever is smaller
■ NIST Traceable Reference Dynamic Blend 1 ppm - 99 ppm Zero ± 2%
Materials (NTRM) – Certified by the Master 100 ppm - 40% Zero ± 1%
National Institute of Standards and Standard Grades
Technology (NIST) and accepted by the
Primary Standard 1 ppm - 9.9 ppm ± 10% ± 0.1 ppm
Environmental Protection Agency (EPA), 10 ppm - 9999 ppm ± 5% ± 1%
as the highest accuracy standards 1.0% - 49% ± 2% ± 1% or 0.02% absolute
commercially available. These Standards whichever is smaller
are the regulatory equivalent to NIST’s
Dynamic Blend 1 ppm - 99 ppm Zero ± 5%
Standard Reference Materials (SRMs).
Standard 100 ppm - 40% Zero ± 2%
The standards are made up of the same
components and are within the analytical Certified Standard 1 ppm - 9.9 ppm ± 20% ± 5%
range of NIST SRMs. 100 ppm - 999 ppm ± 10% ± 2%
0.1% - 49% ± 5% ± 2%
■ Certified Standards – These routine
calibration mixtures are prepared by Benchmark 50 ppm - 40% Zero ± 2%
either gravimetric, volumetric or partial Standard
pressure methods. These mixture Non-Certified 1 ppm - 999 ppm ± 20% N/A
standards are analyzed against Praxair Standard 0.1% - 49% ± 10%
Primary Laboratory Standards (PPLS). (1) Based on available National Institute of Standards and Technology (NIST) SRM concentration.
For environmental standards, NIST (2) Benchmark standards are produced with a “zero” deviation from the customer requested concentration,
traceability can be supplied. within the analytical accuracy of the specific mixtures.
■ Non-Certified – Mixtures are prepared Note: For all mixtures, blend tolerance and analytical accuracy specification may vary depending on the
chemical characteristics of the component and the cylinder size. For mixtures below 500 ppb, please contact
by the same methods and the same care your local Customer Service Representative.
used for Certified Standard Grades.
Analyses are not reported. Blend Tolerance
■ EPA Protocols – These gas mixtures
Requested Concentration
are used for the calibration and audit of
Continuous Emission Monitors (CEMs).
Praxair EPA Protocols are NIST traceable 5.10% 5.20%
with a +1% accuracy and produced in
accordance with the latest EPA specifica-
4.75% 5% 5.25%
tions found in document-600/R93/224
Rev. 9/93. Reported
■ Benchmark Standards – These mix- Mixture Specifications Relative Absolute
Concentration
(From Table 1) Value Value
tures are produced on Praxair’s dynamic
blending system or gravimetrically to Blend Tolerance ± 5% of minor component ± 0.25% Certification
match the nominal concentration you Certification Accuracy ± 2% of minor component ± 0.10% Accuracy
ordered. We provide replacement mix- D
tures that are the same concentration
5
as the one previously ordered.
MIXTURES

MINOR MIXTURE COMPONENTS

HOW TO CREATE YOUR PRAXAIR CUSTOM MIXTURES 3 EASY STEPS


1. List the concentration of each minor 2. Specify desired mixture grade based on 3. Specify desired cylinder style. For first
component (e.g. ppm, vol%) and specify application. See Pg. 5 in this section for time mixture orders, consult Praxair for
the desired balance gas details. the cylinder style best suited for your
volume and quality needs.

COMMON MINOR COMPONENTS IN SPECIALTY MIXTURES


Acetylene Disilane Methyl Bromide
Air Ethane Methyl Chloride
Ammonia Ethyl Chloride Monomethylamine
Argon Ethylene Natural Gas
Arsine Ethylene Oxide Neon
Boron Trichloride Halocarbon-14 Nitric Oxide
Boron Trifluoride Halocarbon-22 Nitrogen
1, 3 - Butadiene Halocarbon-23 Nitrogen Dioxide
Normal Butane Halocarbon-116 Nitrous Oxide
1 - Butene Halocarbon 134A Oxygen
cis - 2 - Butene Halocarbon 218 Phosphine
trans - 2 - Butene Helium Propane
Carbon Dioxide Hydrogen Propylene
Carbon Monoxide Hydrogen Bromide Silane
Chlorine Hydrogen Chloride Sulfur Dioxide
Deuterium Hydrogen Sulfide Sulfur Hexafluoride
Diborane Isobutane Trimethylamine
Dichlorosilane Isobutylene Xenon
Dimethyl Ether Krypton
Dimethylamine Methane

MIXTURE MINOR COMPONENT FAMILIES AVAILABLE


Acetates (Esters) Carbonyls Mercaptans (Thiols) Phenols
Acids Cyanates Metal Hydrides Pyridines
Alcohols Dienes Nitriles Silanes
Aldehydes Ethers Nitro Compounds Silicon Halides
Alkanes Glycols Nonmetal Hydrides Sulfides
Alkynes Halogenated Aliphatics Olefins (Alkenes) Sulfones
Amines Halogenated Aromatics Organometalics Sulfur Bearing
Aromatics Halogenated Olefins Oxides Thiophenes
Bicyclics Halogens Oxyhalides
Boranes Ketones Permanent Gases

Example 1 Example 2 Example 3


Furnace Atmosphere

1200 ppm Carbon Dioxide 25 ppm Sulfur Dioxide 40% Carbon Dioxide
1.0% Oxygen
Balance Nitrogen Balance Air Balance Carbon Monoxide

Certified Standard Primary Master Non-Certified Standard

Praxair Recommended Praxair Recommended Praxair Recommended


Cylinder Style K Cylinder Style AS Cylinder Style T
D
6
MIXTURES

MINOR MIXTURE COMPONENTS

OUTLET CONNECTIONS
Cylinder valve outlet connections are selected for mixtures of two or more components in accordance with the
procedures established by the Compressed Gas Association (CGA). The standard selection method is based
on classifying and grouping components according to certain properties and rating the mixture.

The following table generally illustrates the actual selection guideline.


Typical Specialty Gases Mixture Cylinder Valve Outlet Connections

CGA
Mixture
CGA CONNECTION
Rating TYPE OF MIXTURE
1 INERT- Includes:
Inert gases (argon, nitrogen, helium, etc.) carbon dioxide, halocarbons, sufur hexafluoride, oxygen (not 580
over 5%)

(For carbon dioxide and certain halocarbons - the following may be used -) (320)
(For low pressure mixtures the following may be used) (165, 182, 660)

2 FLAMMABLE - Includes:
Hydrocarbons (methane, ethane, propane, butane, etc.), deuterium, hydrogen, carbon monoxide, fuel-rich 350
fuel-oxidizer mixtures (oxygen < 23%)

(For low pressure mixtures the following may be used) (165, 182, 510)
MILDLY OXIDIZING - Includes:
Air, oxygen (over 5% to 23%), oxygen-rich fuel-oxidizer mixtures (oxygen < 23%), nitrous oxide (<63%) 590
3 OXIDIZING - Oxygen (>23%), nitrous oxide (>63%) 296
4 TOXIC and OXIDIZING - Includes:
Chlorine, nitric oxide, nitrogen dioxide, sulfur dioxide, and other toxics (if more than 5% oxygen) 660
Other TOXIC (flammable or non-flammable) - Includes:
Arsine, diborane, ethylene oxide, methyl bromide, phosphine, silane, etc. 350
(For a few low pressure toxic mixtures, the following may be used) (510)

5 CORROSIVE (Acid or Basic)


ACID - Includes:
Boron trichloride, boron trifluoride, hydrogen bromide, hydrogen chloride, hydrogen sulfide, hydrogen 330
fluoride, phosphorus pentafluoride, sulfur tetrafluoride

Dichlorosilane, trichlorosilane 670/678

BASIC - Includes:
Ammonia and amines 705

6 FLUORINATING COMPONENTS - Includes:


Chlorine trifluoride, fluorine, nitrogen trifluoride, etc. 670

For specific information, please contact your nearest Praxair Customer Service location.

D
7
MIXTURES

D
8
L.P...Sections E&F Dividers 5/27/03 6:57 PM Page 1

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


PRODUCTS In this section . . .
FOR SPECIAL
■ 10 Special Application product lines:
APPLICATIONS Instrumentation
Y M Environmental Y M
LITHO PREP
LITHO PREP

C K Petrochemical C K

Industrial hygiene
Lasers
Healthcare
Biotechnology
Sterilization
Food
Semiconductor

■ Regulatory Compliance

■ Traceability

■ Customer Focus

Y M
yell0w
LITHO PREP
customer: V a n C o r p
C K date: 6/16/99 A magenta

job: Praxair Divider E Outside


LITHO PREP your Digital Film Experts cyan
600 S. County Line Rd.• Bensenville IL, 60106
Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sections E&F Dividers 5/27/03 6:57 PM Page 1

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


PRODUCTS In this section . . .
FOR SPECIAL
■ 10 Special Application product lines:
APPLICATIONS Instrumentation
Y M Environmental Y M
LITHO PREP
LITHO PREP

C K Petrochemical C K

Industrial hygiene
Lasers
Healthcare
Biotechnology
Sterilization
Food
Semiconductor

■ Regulatory Compliance

■ Traceability

■ Customer Focus

Y M
yell0w
LITHO PREP
customer: V a n C o r p
C K date: 6/16/99 A magenta

job: Praxair Divider E Outside


LITHO PREP your Digital Film Experts cyan
600 S. County Line Rd.• Bensenville IL, 60106
Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sections E&F Dividers 5/27/03 6:57 PM Page 2

Y M
LITHO PREP

C K

Vehicle Emissions Food Processing

Film Praxair's
Dispenser ExtendapakTM
Gas

Industrial Hygiene

Instrumentation

Process Control
Y M Y M
LITHO PREP LITHO PREP

C K C K

Biotechnology

Continuous Emissions
Monitoring

Remote Monitoring Semiconductor


Manufacturing

Y M
yell0w
LITHO PREP
customer: V a n C o r p
C K date: 6/16/99 A magenta

job: Praxair Divider E Inside


LITHO PREP your Digital Film Experts cyan
600 S. County Line Rd.• Bensenville IL, 60106
Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sections E&F Dividers 5/27/03 6:57 PM Page 2

Y M
LITHO PREP

C K

Vehicle Emissions Food Processing

Film Praxair's
Dispenser ExtendapakTM
Gas

Industrial Hygiene

Instrumentation

Process Control
Y M Y M
LITHO PREP LITHO PREP

C K C K

Biotechnology

Continuous Emissions
Monitoring

Remote Monitoring Semiconductor


Manufacturing

Y M
yell0w
LITHO PREP
customer: V a n C o r p
C K date: 6/16/99 A magenta

job: Praxair Divider E Inside


LITHO PREP your Digital Film Experts cyan
600 S. County Line Rd.• Bensenville IL, 60106
Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/01-05 5/27/03 5:35 PM Page 1

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


INSTRUMENTATION
GENERAL

Instrumentation Gases In addition, our technical support ■ Gas Chromatography (by detector)
personnel are experienced with the ■ Optical Spectrometry
Obtaining precise, accurate results equipment and its applications,
(absorption and emission)
requires a combination of sensitive enabling them to give you the best
service possible. ■ Mass Spectrometry
analytical equipment and
instrumentation gases. Impurities can ■ Others
contaminate and even damage your At Praxair, we are dedicated to helping
instrumentation, compromising your you select the gas product to achieve For specification and ordering
analytical work. superior results, whether in lab analysis information, the chart provides pure
or process control. The instrumentation gas page references and a complete
Over the years, we have focused reference guide on the following pages summary of instrument mixtures on
extensive resources on research and will assist you in the appropriate page E5 of this section.
development of instrumentation gases. selection of gases and gas grades for
As analytical equipment and your specific instrument needs. The
grade recommendations are based on bout
technology become more advanced
the analytical range/sensitivity of your Ask A 9000
and precise, so do our instrumentation O
gases. These gases are prepared instrument application. The reference Our IS ide 25
u
specifically for use with analytical guide is categorized into analytical And G Facilities
e d
equipment. method/detectors:
Certifi ldwide
Y M W r o Y M
LITHO PREP LITHO PREP

C K C K

E
1

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-1

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/01-05 5/27/03 5:35 PM Page 2

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


INSTRUMENTATION
INSTRUMENT REFERENCE GUIDE

Praxair Gas Grade Recommendations


Analytical Method/
Detector Page Analytical Range Sensitivity
No.
Gas (Sect. Carrier and 0-100 100 ppt- 100 ppb- 100 ppm- Type of Analysis and
Chromatography C) Support Gases ppt 100 ppb 100 ppm 100% Impurity Considerations

TCD (Thermal Conductivity 53/54 N2 N/A N/A NI 5.5 TG NI 5.0 UH Universal Detector
Detector)
Atmospheric contaminants can oxidize
35/36 He N/A N/A HE 5.5 TG HE 5.0 UH the detector filament giving rise to
negative peaks and reduced sensitivity
37 H2 N/A N/A HY 6.0 RS HY 5.0 UH

5/6 Ar N/A N/A AR 6.0 RS AR 5.0 UH

FID (Flame Ionization Detector) 35/36 He N/A N/A HE 5.5 TG HE 5.0 UH/HE 4.6 Z Organic Compounds
Hydrocarbons in carrier and fuel gases
Carriers 53/54 N2 N/A N/A NI 5.5 TG NI 5.0 UH/NI 4.8 Z can give rise to baseline noise and
reduced detector sensitivity. Oxygen and
5/6 Ar N/A N/A AR 6.0 RS AR 5.0 UH/AR 4.8 Z water cause column deterioration and
affect retention time on critical
Combustion Gases 37 H2 N/A N/A HY 6.0 RS HY 5.0 UH/HY 4.5 Z separations.

E5 40% H2 in He N/A UH UH Non-certified

E5 40% H2 in N2 N/A UH UH Non-certified

2/3 Air N/A N/A AI 0.0 HC AI 0.0 HC


Y M Y M
LITHO PREP ECD (Electron Capture Detector) 35/36 He HE 5.5 EC HE 5.5 EC HE 5.5 EC/HE 5.5 TG HE 5.5 TG Halogenated Compounds LITHO PREP

C K Detector response and column life are C K

53/54 N2 NI 5.5 EC NI 5.5 EC NI 5.5 EC/NI 5.5 TG NI 5.5 TG reduced by oxygen and water.
Hydrocarbons and halocarbons can
E5 5% CH4 in Ar-ECD (P-5) ECD ECD ECD ECD produce baseline noise, negative peaks
and plumbing contamination.
E5 10% CH4 in Ar-ECD (P-10) ECD ECD ECD ECD

HID (Helium Ionization Detector) 35/36 He N/A HE 5.5 TG HE 5.5 TG HE 5.5 TG Universal Detector
Atmosphere impurities can cause
35/36 He Purge N/A HE 5.0 UH HE 5.0 UH N/A baseline noise signal polarity and
reduced detector stability and sensitivity.

FPD (Flame Photometric Detector) 35/36 He N/A HE 5.5 TG HE 5.5 TG HE 5.0 UH Sulfur or Phosphorous Compounds
Organics can yield baseline noise and
Carriers 53/54 N2 N/A NI 5.5 TG NI 5.5 TG NI 5.0 UH carbon dioxide can suppress detector
response.
Combustion Gases 37 H2 N/A HY 6.0 RS HY 4.5 Z HY 5.0 UH

2/3 Air N/A AI 0.0 HC AI 0.0 HC AI 0.0 Z

PID (Photo Ionization Detector) Selective Detector - Dependent on


35/36 He N/A HE 5.5 TG HE 5.5 TG N/A
UV Source
Hydrocarbons yield baseline noise, and
53/54 N2 N/A NI 5.5 TG NI 5.5 TG N/A oxygen can suppress detector response.
GC/MS (Mass Spec.) 35/36 He HE 5.5 TG HE 5.5 TG HE 5.5 TG HE 5.0 UH All Compounds
Analytical inaccuracies can result from any
53/54 N2 NI 5.5 TG NI 5.5 TG NI 5.5 TG NI 5.0 UH impurity coinciding with quantified peaks.

5/6 Ar AR 6.0 RS AR 6.0 RS AR 6.0 RS/AR 5.0 UH AR 5.0 UH

AL-800 (High Frequency 5/6 Ar AR 6.0 RS AR 6.0 RS AR 6.0 RS N/A H2, O2, N2, CH4, CO, CO2 in Argon
Discharge Detector)

DID (Discharge Ionization 35/36 He HE 6.0 RS HE 6.0 RS HE 6.0 RS N/A Universal Detector
Detector) Same as HID
35/36 He Purge HE 5.0 UH HE 5.0 UH HE 5.0 UH N/A

USD (Ultrasonic Detector) 5/6 Ar AR 6.0 RS AR 6.0 RS AR 5.0 UH AR 5.0 UH/AR 4.8 Z Universal Detector
Same as HID
35/36 He HE 6.0 RS HE 6.0 RS HE 5.0 UH HE 5.0 UH/HE 4.6 Z

E
2

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-2

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/01-05 5/27/03 5:35 PM Page 3

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


INSTRUMENTATION
INSTRUMENT REFERENCE GUIDE

Praxair Gas Grade Recommendations


Analytical Method/
Detector Page Analytical Range Sensitivity
No.
Optical (Sect. Carrier and 0-100 100 ppt- 100 ppb- 100 ppm- Type of Analysis and
Spectrometry C) Support Gases ppt 100 ppb 100 ppm 100% Impurity Considerations

Absorption

NDIR (Non dispersive Infrared) 2/3 Air AI 0.0 HC AI 0.0 HC AI 0.0 HC AI 0.0 Z Polyatomic and Heteroatomic
Compounds
53/54 N2 NI 6.0 RS NI 5.0 UH NI 4.8 Z NI 4.8 Z

IR (Dispersive Infrared) Polyatomic and Heteroatomic


Compounds
During matrix isolation, oxygen can
- FTIR (Fourier Transform Infrared) 5/6 Ar AR 6.0 RS AR 5.0 UH AR 4.8 OF AR 5.0 UH
oxidize a sample. Moisture interferes with
IR spectra. Impurities coinciding with
- IFG/GFC (Correlation) 53/54 N2 NI 6.0 RS NI 5.0 UH NI 5.0 UH NI 5.0 UH quantified peaks can cause inaccuracies.

PAS (Photoacoustic) 2/3 Air AI 0.0 HC AI 0.0 HC AI 0.0 HC AI 0.0 Z Polyatomic and Heteroatomic
Compounds
53/54 N2 NI 6.0 RS NI 5.0 UH NI 4.8 Z NI 4.8 Z

AA (Atomic Absorption) 1 C2H2 N/A N/A AC 2.6 AA AC 2.6 AA Elemental Analysis


Impurities can cause the flame to discolor
Combustion Gases 11 n-C4H10 N/A N/A BU 2.5 IS BU 2.5 IS or burn unevenly. Furnace atmospheres
require low oxygen and moisture
37 H2 N/A N/A HY 4.5 Z HY 4.5 Z levels to maintain instrument sensitivity.
Y M Y M
LITHO PREP 58 N2O N/A N/A NS 2.5 AA NS 2.5 AA LITHO PREP

C K C K
2/3 Air N/A N/A AI 0.0 Z AI 0.0 Z

5/6 Ar (Flameless) AR 5.0 UH AR 5.0 UH AR 5.0 UH AR 5.0 UH

53/54 N2 N/A N/A NI 5.0 UH NI 5.0 UH

NMR (Nuclear Magnetic 77 LHe Liquid Liquid Liquid Liquid


Resonance)
78 LN2 Liquid Liquid Liquid Liquid Analysis of Molecular Structure

EPR (Electronic Paramagnetic 75 LAr Liquid Liquid Liquid Liquid


Resonance)
77 LHe Liquid Liquid Liquid Liquid Analysis of Molecular Structure

78 LN2 Liquid Liquid Liquid Liquid

LEGEND
AA - Atomic Absorption
UH - Ultra High Purity
RS - Research / Chromatographic
Z - Zero
HC - Hydrocarbon Free
IS - Instrument
OF - Oxygen Free
TG - Trace Analytical
EC - Electron Capture Detector

E
3

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-3

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/01-05 5/27/03 5:35 PM Page 4

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


INSTRUMENTATION
INSTRUMENT REFERENCE GUIDE

Praxair Gas Grade Recommendations


Analytical Method/
Detector Page Analytical Range Sensitivity
No.
Optical (Sect. Carrier and 0-100 100 ppt- 100 ppb- 100 ppm- Type of Analysis and
Spectrometry C) Support Gases ppt 100 ppb 100 ppm 100% Impurity Considerations

Emission

Atomic Emission

- ICP (Inductive Coupled 5/6 Ar AR 6.0 RS AR 4.8 IC AR 4.8 IC AR 4.8 IC Elemental Analysis
Plasma)
76 LAr Liquid Liquid Liquid Liquid

53/54 N2 NI 6.0 RS NI 5.0 UH NI 5.0 UH NI 5.0 UH

37 H2 HY 6.0 RS HY 5.0 UH HY 5.0 UH HY 5.0 UH

Arc or Spark Emission 5/6 Ar AR 5.0 UH AR 5.0 UH AR 5.0 UH AR 4.8 Elemental Analysis

37 H2 HY 5.0 UH HY 5.0 UH HY 5.0 UH HY 4.5 Z

E5 5% Ar in H2 Certified Standard Certified Standard Certified Standard Certified Standard

Chemiluminescence 2/3 Air AI 0.0 CE AI 0.0 CE AI 0.0 CE AI 0.0 CE NO-NO2-NOX Hydrides and O3

53/54 N2 NI 5.5 CE NI 5.5 CE NI 5.5 CE NI 5.5 CE


Y M Y M
LITHO PREP 59 O2 OX 4.3 UH OX 4.3 UH OX 4.3 UH OX 4.3 UH LITHO PREP

C K C K

Fluorescence UV 2/3 Air AI 0.0 VC AI 0.0 VC AI 0.0 VC AI 0.0 VC SO2-H2S-Organic Compounds

53/54 N2 NI 5.5 CE NI 5.5 CE NI 5.5 CE NI 5.5 CE

XRF (Fluorescence X) E5 10% CH4 in Ar Certified Standard Certified Standard Certified Standard Certified Standard Elemental Analysis

E5 1.3% n-C4H10 in He Certified Standard Certified Standard Certified Standard Certified Standard

E5 0.95% i-C4H10 in He Certified Standard Certified Standard Certified Standard Certified Standard

E5 1.5% C3H8 in He Certified Standard Certified Standard Certified Standard Certified Standard

78 LN2 Liquid Liquid Liquid Liquid

Mass Spectrometry

MS (Under Vacuum) 5/6 Ar AR 6.0 RS AR 6.0 RS AR 5.0 UH AR 5.0 UH All Compounds

53/54 N2 NI 6.0 RS NI 5.5 TG NI 5.5 TG NI 5.5 TG

35/36 He HE 6.0 RS HE 5.5 TG HE 5.5 TG HE 5.5 TG

APIMS (Atmospheric 5/6 Ar AR 6.0 RS N/A N/A N/A All Gases-High Sensitivity
Pressure Ionization
Mass Spectrometer) 53/54 N2 NI 6.0 RS N/A N/A N/A

35/36 He HE 6.0 RS N/A N/A N/A

LEGEND
UH - Ultra High Purity
RS - Research
IC - Inductive Coupled Plasma
CE - Continuous Emissions Monitoring
(See Pure Gas Section for correct definition)
TG - Trace Analytical
Z - Zero
VC - Volatile Organic Compound Free
HC - Hydrocarbon Free
E
4

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-4

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/01-05 5/27/03 5:35 PM Page 5

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


INSTRUMENTATION
INSTRUMENT REFERENCE GUIDE / MIXTURE SUMMARY

Praxair Gas Grade Recommendations


Analytical Method/
Detector Page Analytical Range Sensitivity
No.
(Sect. Carrier and 0-100 100 ppt- 100 ppb- 100 ppb- Type of Analysis and
Others C) Support Gases ppt 100 ppb 100 ppm 100% Impurity Considerations

Nuclear Counter E5 10% CH4 in Ar Certified Standard Certified Standard Certified Standard Certified Standard Measurement of Radioactivity

E5 10% CO2 in Ar Certified Standard Certified Standard Certified Standard Certified Standard

E5 1.3% n-C4H10 in He Certified Standard Certified Standard Certified Standard Certified Standard

E5 0.95% i-C4H10 in He Certified Standard Certified Standard Certified Standard Certified Standard

Hydrometer 2/3 Air AI 0.0 HC AI 0.0 HC AI 0.0 HC AI 0.0 Z Moisture in All Gases

53/54 N2 NI 6.0 RS NI 6.0 RS NI 6.0 RS NI 5.0 UH

Paramagnetic Analyzer 53/54 N2 N/A N/A N/A NI 4.8 OF Oxygen In All Gases

D6 O2 in N2 Certified Standard Certified Standard Certified Standard Certified Standard

Carbon and Sulfur In Steel 5/6 Ar AR 5.0 UH AR 5.0 UH AR 5.0 UH AR 5.0 UH Analysis of Carbon, Sulfur and

35/36 He HE 5.0 UH HE 5.0 UH HE 5.0 UH HE 5.0 UH Gases (N2-H2-O2) in Steel

53/54 N2 NI 5.0 UH NI 5.0 UH NI 5.0 UH NI 5.0 UH

Y M 59 O2 OX 5.0 RS OX 5.0 RS OX 5.0 RS OX 5.0 RS Y M


LITHO PREP LITHO PREP

C K C K

Instrumentation Mixture Summary


Regulator
Product Mixture Cylinder Recommendations
Part No. Description Application Style CGA (See Section F, Page 2)

IG HEHY8.5-K 8.5% H2 in He Carrier Gas for K 350 400 SERIES : Non-corrosive


GC-Thermal Conductivity Detectors 300 SERIES : Non-corrosive
IG FI1 K 40% H2 in He (FID Fuel) FID Fuel Gas for K 350 200 SERIES : Non-corrosive
IG FI2 K 40% H2 in He UH (FID Fuel) GC-Flame Ionization Detectors K 350
(THC < 0.1 ppm)
IG FI3 K 40% H2 in N2 (FID Fuel) K 350
IG FI4 K 40% H2 in N2 UH (FID Fuel) K 350
(THC < 0.1 ppm)
IG ECD1 AS 5% CH4 in Argon-ECD (P-5) Make-up Gas for AS 350
IG ECD2 AS 10% CH4 in Argon-ECD (P-10) GC-Electron Capture Detectors AS 350
IG P10 K 10% CH4 in Ar (P-10) XRF (Fluorescence X) K 350
IG XRF2 K 1.3% n-C4H10 in He XRF (Fluorescence X) K 350
IG XRF3 K 0.95% i-C4H10 in He XRF (Fluorescence X) K 350
IG XRF4 K 1.5% C3H8 in He XRF (Fluorescence X) K 350
IG P5 K 5% CH4 in Ar (P-5) Carrier Gas for Proportional Counters K 350
IG P10 K 10% CH4 in Ar (P-10) Carrier Gas for Proportional Counters K 350
IG NC3 K 10% CO2 in Ar Nuclear Counter K 580
IG NC4 K 1.3% n-C4H10 in He (Quench Gas) Quench Gas K 350
IG NC5 K 0.95% i-C4H10 in He Carrier Gas for Geiger-Muller K 350
IG NC6 K 5% Ar in H2 Spark Emission K 350

Instrument mixtures are supplied as certified standards, but can be produced to meet primary standard
or non-certified grade specifications.

E
5

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-5

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/06-16 5/27/03 5:33 PM Page 6

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


ENVIRONMENTAL
PROCESS ENHANCEMENT AND CALIBRATION PRODUCTS

We divide our Environmental Process Enhancement Products ■ An atmosphere of Nitrogen, used when
producing electronic circuit boards,
product line into two broad reduces defects, cuts costs and eliminates
■ Praxair’s proprietary wastewater
areas; Process Enhancement treatment systems use Oxygen to the use of chlorofluorocarbons
and Specialty Gases improve the digestion of waste-eating
microbes and to reduce emissions from ■ Hydrogen is used at refineries to create
Calibration Products. cleaner, reformulated fuels for vehicles
polluted lagoons and sewage-treatment
plants
Atmospheric gases, such as oxygen, ■ Carbon Dioxide is used as an
nitrogen and argon, and process gases ■ Injected into electric steel furnaces, alternative to sulfuric acid for pH balance
such as hydrogen and carbon dioxide, Oxygen enhances melting and reduces control, because it is easier to control and
are used in manufacturing processes power costs, while converting potential doesn’t lower your pH balance too far.
to achieve a broad range of carbon monoxide emissions into extra And, because it’s safer to handle, it’s
energy, using Praxair’s patented technology. easier to meet stringent government
environmental benefits. Some of these
regulations
many uses are: ■ Oxygen is used in Pulp and Paper
Bleaching process, making paper mills ■ Also, Carbon Dioxide is used as a
more efficient and environmentally friendly propellant in pressure packaging, in many
cases replacing fluorinated hydrocarbons
■ Used in conjunction with Praxair’s
proprietary combustion technology,
Y M
Oxygen reduces nitrogen oxide emissions Y M
LITHO PREP
and decreases fuel consumption in glass LITHO PREP

C K C K
furnace, cement kilns and waste incinerators

Specialty Gases Calibration


Products

Today, industry must carefully monitor ■ Stationary Source Emissions ■ Ambient Monitoring (air, soil, and
its environmental emissions and use Monitoring (40 CFR Part 60, 64, 75, water)
precise reference standards to obtain 264, 266, and 503) ■ Environmental Laboratories
accurate measurements. Praxair is a ■ Utilities ■ Remote Monitoring Stations (e.g.,
■ Co-generation Photochemical Air Monitoring
pioneer in producing highly accurate
■ Pulp and Paper Plants Systems (PAMS))
calibration gas standards and ultra
■ Petrochemical
pure zero gases for a wide variety of ■ Mobile Sources
■ Natural Gas Turbine Pumping Stations
emissions applications. ■ Incinerators, including Waste to ■ Motor Vehicle Manufacturers
Energy plants (emissions certification)
Declaration of Equivalence ■ Sewage Sludge ■ State Vehicle Inspection &
agreements between NIST, EPA, NMi ■ Boilers and Industrial Furnaces Maintenance (I&M) Testing
and other national metrology ■ Cement Kilns ■ Aircraft Engine Testing
laboratories ensure many Praxair ■ Independent Stack Testing ■ Catalyst Manufacturers
mixtures are traceable internationally ■ Independent Testing Laboratories
and all are consistent, wherever they
are produced.

Among our key Environmental markets


segments are:

E
6

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-6

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/06-16 5/27/03 5:33 PM Page 7

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


ENVIRONMENTAL
PRODUCT SUMMARY

Praxair’s 17 North American Specialty Mixture Mixture Component Blnd. Prep. Laboratory Analytical
Gases laboratories are staffed with Grade Concentration Range Tolerance Accuracy
thoroughly trained chemists able to provide
Environmental Grades
information on environmental calibration
applications. NTRM1 N/A N/A ≤1%

EPA Protocol 1
2 ppm - 99 ppm ±10% ±1% NIST Traceable
Praxair sales, technical support and 100 ppm - 24% ±5% ±1% NIST Traceable
production teams will provide you with
the proper zero gas or calibration mixtures Benchmark Standard2 See Standard Grade
accuracy and NIST traceability. They will section below
also recommend the correct gas delivery to
Primary Master/ See Master Grade
meet your specific monitoring needs. Dynamic Blend Master section below

Additionally, our laboratories provide the Certified Standard See Standard Grade
appropriate Certificate of Analysis, supplied section below
with the cylinder, required by federal, state
Micro-Blend 500 ppb - 999 ppb ±15% ±15%
(provincial), local environmental agencies or
your internal quality program. Master Grades

Primary Master 1
1 ppm - 9.9 ppm ±10% ±0.1 ppm
Our extensive environmental product line
10 ppm - 9999 ppm ±5% ±1%
includes: 1.0% - 49% ±2% ±1% or 0.02% absolute
■ NIST Traceable Reference whichever is smaller
Materials (NTRM)
Dynamic Blend Master1 1 ppm - 99 ppm Zero ±2%
Y M
LITHO PREP
■ Research Gas Materials (RGM) 100 ppm - 40% Zero ±1%
Y M
LITHO PREP

C K ■ EPA Protocol Standards C K


Standard Grades
■ Primary Master Grade
Primary Standard 1 ppm - 9.9 ppm ±10% ±0.1 ppm
■ Micro-Blend
10 ppm - 9999 ppm ±5% ±1%
■ Dynamic-Blend Master and 1.0% - 49% ±2% ±1% or 0.02% absolute
Standard Grades whichever is smaller
■ Primary and Certified Dynamic Blend Standard 1 ppm - 99 ppm Zero ±5%
Standard Grades 100 ppm - 40% Zero ±2%
■ Benchmark Standard Grade
Certified Standard 1 ppm - 99 ppm ±20% ±5%
■ Zero Gases; 100 ppm - 999 ppm ±10% ±2%
■ VOC Free grade Air, Nitrogen 0.1% - 49% ±5% ±2%
■ CEM Zero grade Air and Nitrogen
Benchmark Standard2 50 ppm - 40% Zero ±2%
■ Vehicle Emission Air, Nitrogen
and UHP FID Fuel Non-Certified Standard 1ppm - 999 ppm ±20% N/A
0.1% - 49% ±10%
■ Mobile Source Products;
■ NIST Traceable Mixtures BAR -74, (1) Based on available National Institute of Standards and Technology (NIST) SRM concentration.
-80, -84, -90, -97 — containing CO, (2) Benchmark standards are produced with a “zero” deviation from the customer requested concentration, within the
analytical accuracy of the specific mixtures.
CO2, C3H8, and NO in high and NOTE: For all mixtures, blend tolerance and analytical accuracy specification may vary depending on the chemical
low pressure cylinders characteristics of the component and the cylinder size. For mixtures below 500 ppb, please contact your local Customer
Service Representative.
■ Supercritical Fluids (Ultra pure
carbon dioxide, and mixtures with
modifiers) Ask About Our
■ SFC Grade for chromatography, ISO 9000 And Guide 25
■ SFE Grade for extraction. Certified Facilities
Worldwide
Common Components: Balance Nitrogen or Air

Component CGA Component CGA Component CGA Component CGA


Ammonia 705 Carbon Monoxide 350/590 Hydrogen Chloride 330 Nitrogen Dioxide 660
Aromatic Hydrocarbons 350/590 Chlorinated Hydrocarbons 580/350/590 Hydrogen Sulfide 330 Oxygen 540/590/296
Butane 350/590 Chlorofluorocarbon 580/350/590 Methane 350/590 Propane 350/590
Carbon Dioxide 580/590 EPA Method TO-VOC 350/590 Nitric Oxide1 660 Sulfur Dioxide 660
(1) Balance nitrogen only.
E
7

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-7

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/06-16 5/27/03 5:33 PM Page 8

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


ENVIRONMENTAL
EPA METHODS

Praxair environmental products are developed ■ EPA Method 7E ■ EPA Method 15


in compliance with the current legislation “Determination of Nitrogen Oxides “Determination of Hydrogen Sulfide,
promulgated by Federal, State (Provincial) Emissions From Stationary Sources Carbonyl Sulfide, and Carbon Disulfide
and local air quality authorities. (Instrumental Analyzer Procedure)” Emissions From Stationary Sources”

Praxair’s extensive product line meets all ■ Certified Standard: ■ Primary Master or Certified Standard:
certification, calibration and analytical Nitric Oxide in Nitrogen (Analytical Hydrogen Sulfide in Nitrogen – (NIST
equipment auditing requirements. Additionally, Traceable) for Sample Line Loss
Certification ± 2%)
our laboratories will provide the required ■ EPA Protocol: ■ EPA Protocol:
Certificate of Analysis with the cylinder to Hydrogen Sulfide in Nitrogen
Nitric Oxide in Nitrogen
ensure your records are complete and comply.
■ Zero Gas: ■ Carrier Gases:
Praxair environmental products meet the CEM Zero Air Zero Helium or Zero Nitrogen
needs of EPA methods defined in 40 CFR Part
60. The following summary has been prepared ■ EPA Method 10 ■ Fuel Gas:
to assist you with the selection of gases Zero Hydrogen
“Determination of Carbon Monoxide
required to conduct the tests described in the
Emissions From Stationary Sources” ■ Combustion Gases:
following EPA methods: CEM Zero Air or HC Free Oxygen
■ Primary or Certified Standard:
Carbon Monoxide in Nitrogen ■ Diluent Gas:
■ EPA Method 3A (Analytical Certification ± 2%) CEM Zero Air
“Determination of Oxygen and Carbon
■ EPA Protocol:
Dioxide Concentrations in Emissions ■ Compressed Air:
Carbon Monoxide in Nitrogen Extra Dry
From Stationary Sources (Instrumental
Analyzer Procedure)” ■ Zero Gas:
■ EPA Method 15A
■ Certified Standard: CEM Zero Nitrogen
Y M “Determination of Total Reduced Sulfur Y M
LITHO PREP Oxygen in Nitrogen; Carbon Dioxide Emissions From Sulfur Recovery Plants in LITHO PREP

C K
in Nitrogen or Air; Carbon ■ EPA Method 10A Petroleum Refineries” C K

Dioxide/Sulfur Dioxide, Oxygen/Sulfur “Determination of Carbon Monoxide


Dioxide or Oxygen/Carbon Emissions in Certifying Continuous ■ Certified Standard:
Dioxide/Sulfur Dioxide in Nitrogen > 100 ppm Carbonyl Sulfide in Nitrogen
Emission Monitoring Systems at – for Recovery Check Gas
■ EPA Protocol: Petroleum Refineries”
Oxygen in Nitrogen; Carbon Dioxide ■ Combustion Gases:
in Nitrogen or Air; Carbon ■ Primary Master or
UZAM Air (certified; < 50 ppb TRS,
Dioxide/Sulfur Dioxide, Oxygen/ Certified Standard: <10 ppm THC)
Sulfur Dioxide or Oxygen/Carbon 50-1000 ppm Carbon Monoxide in
Dioxide/Sulfur Dioxide in Nitrogen Nitrogen (Analytical Certification ±2% ■ Diluent Gas:
■ Zero Gas: CEM Zero Nitrogen or NIST Traceable) UZAM Air
CEM Zero Air
■ EPA Method 16
■ EPA Method 10B
■ EPA Method 6C “Semicontinuous Determination of Sulfur
“Determination of Carbon Monoxide Emissions From Stationary Sources”
“Determination of Sulfur Dioxide Emissions From Stationary Sources”
Emissions From Stationary Sources ■ Certified Standard: ■ Primary Master or Certified Standard:
(Instrumental Analyzer Procedure)” Hydrogen Sulfide in Nitrogen – (NIST
20, 200, and 1000 ppm Carbon Traceable) for Sample Line Loss
■ Certified Standard: Monoxide in Nitrogen; 1000 ppm
Sulfur Dioxide in Nitrogen or Air; Methane in Air ■ EPA Protocol:
Sulfur Dioxide/Carbon Dioxide, Sulfur Hydrogen Sulfide in Nitrogen
■ EPA Protocol:
Dioxide/Oxygen or Sulfur Dioxide/ Carbon Monoxide in Nitrogen ■ Carrier Gases:
Carbon Dioxide/Oxygen in Nitrogen Zero Helium or Zero Nitrogen
■ Carrier Gas:
(Analytical Certification ± 2%)
Zero Helium or HC Free Oxygen ■ Fuel Gas:
■ EPA Protocol: Sulfur Dioxide in
■ Fuel Gas: Zero Hydrogen
Nitrogen or Air; Sulfur Dioxide/Carbon
UHP Hydrogen
Dioxide, Sulfur Dioxide/Oxygen or ■ Combustion Gases:
Sulfur Dioxide/ Carbon ■ Combustion Gases: UZAM Air or Research Oxygen
Dioxide/Oxygen in Nitrogen HC Free Air or HC Free Oxygen
■ Diluent Gas:
■ Zero Gas: UZAM Air (certified; < 50 ppb Total Sulfur,
CEM Zero Air EXCLUSIVE!! < 10 ppm H2O, < 10 ppm THC)
Praxair now provides
calibration mixtures in ■ Compressed Air:
Extra Dry
E Silcosteel® treated cylinders
and valves.
8

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-8

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/06-16 5/27/03 5:33 PM Page 9

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


ENVIRONMENTAL
EPA METHODS

■ EPA Method 16A ■ EPA Method 20 ■ EPA Method 25B


“Determination of Total Reduced Sulfur “Determination of Nitrogen Oxides, “Determination of Total Gaseous Organic
Emissions From Stationary sources Sulfur Dioxide and Diluent Emissions Concentration Using a Nondispersive
(Impinger Technique)” From Stationary Gas Turbines” Infrared Analyzer ”

■ Certified Standard: ■ Certified Standard: ■ Certified Standard:


< 100 ppm Hydrogen Sulfide in Nitrogen Nitric Oxide in Nitrogen; Oxygen in ■ EPA Protocol:
– for Recovery Check Gas Nitrogen; Carbon Dioxide in Air
■ Zero Gas:
■ EPA Protocol:
■ EPA Protocol: Nitric Oxide in Nitrogen; Oxygen in
Hydrogen Sulfide in Nitrogen Same as EPA Method 25A
Nitrogen; Carbon Dioxide in Air
■ EPA Method 25C
■ Combustion Gases: ■ Zero Gases:
UZAM Air (certified; < 50 ppb TRS, “Determination of Nonmethane Organic
CEM Zero Air or VOC Free Nitrogen Compounds (NMOC) in MSW Landfill
< 10 ppm THC)
Gases”
■ EPA Method 21
■ Diluent Gas: “Determination of Volatile Organic ■ Certified Standard:
CEM Zero Air Compound Leaks” Same Standards as Method 25
■ EPA Method 16B ■ Certified Standard: ■ Carrier Gases:
“Determination of Total Reduced Sulfur VOCs in Nitrogen or Air (Analytical UHP Helium , HC Free Oxygen or HC
Emissions From Stationary Sources” Certification ±2%) Free Air
■ Primary Master or Certified Standard: ■ Zero Gases: ■ Fuel Gas:
Sulfur Dioxide in Nitrogen — (NIST VOC Free Air or VOC Free Nitrogen UHP Hydrogen
Traceable); Hydrogen Sulfide in
■ EPA Method 25 ■ Combustion Gases:
Nitrogen — for Recovery Check Gas
“Determination of Total Gaseous HC Free Air or HC Free Oxygen
■ EPA Protocol: Nonmethane Organic Emissions as
M Sulfur Dioxide in Nitrogen Carbon” ■ Auxiliary Oxygen: M
Y Y
Zero Oxygen
■ Certified Standard:
LITHO PREP LITHO PREP

C K
■ Carrier Gases: C K

Zero Helium or Zero Nitrogen 1% Methane in Air; 20 ppm, 200 ppm, ■ EPA Method 25D
and 3000 ppm Propane in Air; 50 ppm,
500 ppm, and 1% Carbon Dioxide in “Determination of the Volatile Organic
■ Fuel Gas: Air; 50 ppm Carbon Monoxide, 50 ppm Concentration of Waste Samples”
Zero Hydrogen Methane, 2% Carbon Dioxide, and 20
ppm Propane in Air; 50 ppm Hexane in ■ Certified Standard:
■ Combustion Gases: Air; 20 ppm Toluene in Air; 100 ppm 1% 1,1 Dichloroethylene,
UZAM Air (certified; < 50 ppb TRS, Methanol in Air — (Analytical 10% Propane in Nitrogen
< 10 ppm THC) Certification ±5%)
■ Purge Gas:
■ Diluent Gas: ■ Carrier Gases: UHP Nitrogen
UZAM Air (certified; < 50 ppb TRS, UHP Helium, HC Free Oxygen, or HC
< 10 ppm THC) Free Air ■ Carrier Gases:
UHP Hydrogen or Zero Nitrogen
■ Compressed Air: ■ Fuel Gas:
Extra Dry UHP Hydrogen ■ Fuel Gas:
UHP Hydrogen
■ EPA Method 18 ■ Combustion Gases:
HC Free Air or HC Free Oxygen ■ Combustion Gases:
"Measurement of Gaseous Organic HC Free Air or HC Free Oxygen
Compound Emissions by Gas ■ Auxiliary Oxygen:
Chromatography” Zero Oxygen ■ EPA Method 25E
■ Primary Master or Certified Standard: ■ EPA Method 25A “Determination of Vapor Phase Organic
VOCs in Nitrogen or Air – (NIST Traceable) Concentration in Waste Samples”
“Determination of Total Gaseous
Organic Concentration Using a Flame ■ Primary Master or Certified Standard:
■ Carrier Gases: Ionization Analyzer”
UHP Helium or TOC Hydrogen Propane in Nitrogen or Air (Analytical
Certification ±5% NIST Traceable)
■ Certified Standard:
■ Fuel Gas: Organics in Nitrogen or Air ■ Carrier Gas:
UHP Hydrogen (Analytical Certification ±2%)
Zero Nitrogen
■ Combustion Gases: ■ EPA Protocol:
Propane in Air or Nitrogen ■ Fuel Gas:
HC Free Air or HC Free Oxygen Zero Hydrogen
(Analytical Certification ± 2%)
■ Diluent Gas: NOTE: Other organic mixtures available ■ Combustion Gas:
VOC Free Air or VOC Free Nitrogen HC Free Air or HC Free Oxygen
■ Fuel Gases:
■ Zero Gas: 40% Hydrogen in Helium or
VOC Free Air or VOC Free Nitrogen 40% Hydrogen in Nitrogen — UHP Grade
■ Zero Gas: UZAM Air E
9

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-9

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/06-16 5/27/03 5:33 PM Page 10

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


ENVIRONMENTAL
NTRMS

NIST Traceable Reference in the past. These mixtures are similar in Available mixture components include:
Materials (NTRMs) composition to NIST primary and SRM
■ Carbon Dioxide
standards. However, because the
■ Carbon Monoxide
NIST Traceable Reference Materials concentration of the certified component can
■ Methane
(NTRM) — Certified by the National be bracketed by existing primary NIST
■ Nitric Oxide
Institute of Standards and Technology (NIST) standards, NTRM component concentrations
can fall above, below or between existing ■ Oxygen
and accepted by the Environmental
SRM concentrations. This offers end users ■ Propane
Protection Agency (EPA), as the highest
additional calibration reference points for ■ Sulfur Dioxide
accuracy standards commercially produced.
These Standards are the regulatory greater accuracy and lower uncertainty in ranges that fall closely above, below; or
equivalent to NIST’s Standard Reference measurements. between existing NIST SRM concentrations.
Materials (SRMs). These materials are made
up of the same components and are within NTRMs are manufactured in a batch by NOTE: Because of the extensive production and
the analytical range of NIST SRMs. Praxair, with NIST assigning the component certification process of NTRMs, and the need to
work closely with NIST, Praxair submits a
concentration. The NTRM program was
production schedule to NIST six (6) months in
The NIST Traceable Reference Materials designed to replace the EPA’s Certified
advance of each batch’s scheduled production.
(NTRMs) program, was developed in a Reference Material (CRM) program. EPA Please inquire as to the timing and availability
consortium with NIST, EPA, and industry has stated that it accepts NTRMs in place of of your particular NTRM standard.
participation. The program was intended to CRMs and allows their use as equivalent to
increase the availability of NIST traceable SRMs for certification of emissions and
primary gas standards to industry. NTRMs production of mixture standards, such as EPA
supplement the supply of existing gaseous Protocols.
Y M Y M
LITHO PREP Standard Reference Materials (SRMs) and LITHO PREP

C K
can be used wherever SRMs have been used C K

RGMs

NIST has also developed a methodology The RGM process can provide NIST Please consult your Praxair Specialty Gases
to work collaboratively with specialty traceability for new components as & Equipment technical sales representative
gas manufacturers to produce Research required by government, industry or quality for information on the feasibility and
Gas Material (RGM) standards. RGMs processes. These new standards are availability of your standard.
allow Praxair to produce new gaseous produced in batches. Also, because of
components, or existing SRM components the extensive production and certification
at outlying concentration ranges as process of RGMs, and the need to work
“NIST traceable” standards. closely with NIST, Praxair would be pleased
to discuss your specific requirement.

RCE
A SOU EW
FOR NCEABLE
RA
NIST TNDARDS
STA

E
10

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-10

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/06-16 5/27/03 5:33 PM Page 11

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


ENVIRONMENTAL
EPA PROTOCOLS

EPA Protocols EPA Protocol Mixtures


These gas mixtures are used for the
BINARY MIXTURES
calibration and audit of Continuous
Emission Monitors (CEMs). Praxair EPA Certification 400 Series
EPA Protocols are NIST traceable Part No. Product Description Periods (months) CGA Regulators
with a ±1% accuracy, produced in < 0.20 ppm Aliphatic Organic Gases
EV ALIME Balance Nitrogen 6 350 Please Inquire
accordance with the latest EPA
> 0.20 ppm Aliphatic Organic Gases
specifications. EV ALIME Balance Nitrogen 36 350
< 0.25 ppm Aromatic Organic Gases
EPA Protocol gas mixtures are EV AROME Balance Nitrogen 6 350 Please Inquire
required for the monitoring of > 0.25 ppm Aromatic Organic Gases
emissions from stationary sources. EV AROME Balance Nitrogen 36 350
The benefits to you include: < 0.25 ppm Benzene
EV NIBZXE Balance Nitrogen 6 350 Corrosive
■ Certified analytical accuracy of > 0.25 ppm Benzene
of ±1% NIST traceable for EV NIBZXE Balance Nitrogen 36 350
reliable analyzer, certification, < 300 ppm Carbon Dioxide
calibration and audit. EV AICDXE Balance Air or 6 590 Non-Corrosive
EV NICDXE Balance Nitrogen 6 580
> 300 ppm Carbon Dioxide
■ Multiple production locations to EV AICDXE Balance Air or 36 590
ensure an uninterrupted supply EV NICDXE Balance Nitrogen 36 580
of Protocol standards. < 8 ppm Carbon Monoxide
EV AICOXE Balance Air or 6 590 Non-Corrosive
■ Standards are labeled and EV NICOXE Balance Nitrogen 6 350
Y M supplied with the complete and > 8 ppm Carbon Monoxide Y M
LITHO PREP
EV AICOXE Balance Air or 36 590 LITHO PREP

required documentation to
C K
EV NICOXE Balance Nitrogen 36 350 C K

ensure you are in compliance.


< 4 ppm Hydrogen Sulfide
EV AIHSXE Balance Air or 6 330 Corrosive
■ Praxair’s cylinder treatment EV NIHSXE Balance Nitrogen 6 330
process ensures maximum > 4 ppm Hydrogen Sulfide
allowed shelf life within the EV AIHSXE Balance Air or 6 330
stated analytical uncertainty. EV NIHSXE Balance Nitrogen 12 330
< 1 ppm Methane
■ Praxair maintains a complete EV AIMEXE Balance Air 6 590 Non-Corrosive
range of NIST Standard > 1 ppm Methane
EV AIMEXE Balance Air 36 590
Reference Materials (SRMs) and
NIST Traceable Reference < 4 ppm Nitric Oxide
EV NINOXE Balance Nitrogen 6 660 Corrosive
Materials (NTRMs). > 4 ppm Nitric Oxide
EV NINOXE Balance Nitrogen 24 660
Technical support, to address any < 80 ppm Nitrogen Dioxide
application questions you have, is EV AINDXE Balance Air 6 660 Corrosive
available from your Praxair > 80 ppm Nitrogen Dioxide
Technical Sales Representative. EV AINDXE Balance Air 24 660
< 0.8% Oxygen
EV NIOXX1E Balance Nitrogen 6 580 Non-Corrosive
> 0.8% Oxygen
EV NIOXX1E Balance Nitrogen 36 580/590/296
ut < 1 ppm Propane
e abo f
Inquir line o EV AIPRXE Balance Air or 6 590 Non-Corrosive
ir ’s
Praxa ® eated gas EV NIPRXE Balance Nitrogen 6 350
el tr ts > 1 ppm Propane
S oste componen
ilc EV AIPRXE Balance Air or 36 590
dlin g F76 )
han 75- EV NIPRXE Balance Nitrogen 36 350
ages F
(see p 10 ppm to 39 ppm Sulfur Dioxide
EV AISDXE Balance Air or 6 660 Corrosive
EV NISDXE Balance Nitrogen 6 660
40 ppm to 499 ppm Sulfur Dioxide
EV AISDXE Balance Air or 24 660
EV NISDXE Balance Nitrogen 24 660
> 500 ppm Sulfur Dioxide
EV AISDXE Balance Air or 36 660
EV NISDXE Balance Nitrogen 36 660 E
11

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-11

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/06-16 5/27/03 5:33 PM Page 12

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


ENVIRONMENTAL
EPA PROTOCOLS

EPA Protocol Mixtures

Reminders MULTI-COMPONENT MIXTURES – Typical, other concentrations and component combinations available.
EPA Certification 400 Series
1. Multi-component Protocols are Part No. Product Description Periods (months) Regulators
assigned a certification period > 300 ppm Carbon Dioxide, > 0.8% Oxygen
based on the minor component EV NICDOXXE Balance Nitrogen 36 Non-Corrosive
or balance gas with the > 8 ppm Carbon Monoxide, > 300 ppm Carbon Dioxide
shortest certification period. EV NICDCOXE Balance Nitrogen 36 Non-Corrosive
> 8 ppm Carbon Monoxide, > 0.8% Oxygen
2. Protocol concentrations lower EV NICDCOXE Balance Nitrogen 36 Non-Corrosive
than those listed will have an > 1 ppm Methane, > 0.8% Oxygen
initial 6 month certification EV NIMEOXXE Balance Nitrogen 36 Non-Corrosive
period; upon re-certification, > 4 ppm Nitric Oxide, > 300 ppm Carbon Dioxide
acceptable cylinders will have EV NICDNOXE Balance Nitrogen 24 Corrosive
extended certifications.
> 4 ppm Nitric Oxide, > 8 ppm Carbon Monoxide
EV NICONOXE Balance Nitrogen 24 Corrosive
3. Some mixtures may not be
available due to critical mixture > 1 ppm Propane, > 8 ppm Carbon Monoxide
limitations and safety EV AICOPRXE Balance Air 36 Non-Corrosive
considerations. > 500 ppm Sulfur Dioxide, > 300 ppm Carbon Dioxide
EV NICDSDXE Balance Nitrogen 36 Corrosive
4. Analytical uncertainty for 40 to 499 ppm Sulfur Dioxide, > 300 ppm Carbon Dioxide
certain mixture components EV NICDSDXE Balance Nitrogen 24 Corrosive
Y M and concentrations may vary. > 500 ppm Sulfur Dioxide, > 4 ppm Nitric Oxide Y M
LITHO PREP

C K
The actual analytical uncertainty EV NINOSDXE Balance Nitrogen 24 Corrosive LITHO PREP

C K
will be specified on the 40 to 499 ppm Sulfur Dioxide, > 4 ppm Nitric Oxide
Certificate of Analysis. EV NICDSDXE Balance Nitrogen 24 Corrosive
> 300 ppm Carbon Dioxide,
5. Trace concentrations of other > 8 ppm Carbon Monoxide, > 4 ppm Nitric Oxide
pollutants in the mixture can be EV X4E1 Balance Nitrogen 24 Corrosive
certified on request. > 300 ppm Carbon Dioxide,
> 8 ppm Carbon Monoxide, > 0.8% Oxygen
6. Reference Section C pages EV X4E2 Balance Nitrogen 36 Non-Corrosive
2 (air) and 53 (nitrogen) for > 300 ppm Carbon Dioxide,
CEM zero grade gas products. > 8 ppm Carbon Monoxide, > 1 ppm Propane
EV X4E3 Balance Nitrogen 36 Non-Corrosive
7. Other mixture components or > 300 ppm Carbon Dioxide,
concentrations may be > 8 ppm Carbon Monoxide, > 500 ppm Sulfur Dioxide
available, please inquire. EV X4E4 Balance Nitrogen 36 Corrosive
> 300 ppm Carbon Dioxide,
8. Other cylinder sizes and
> 4 ppm Nitric Oxide, > 500 ppm Sulfur Dioxide
materials (e.g., steel) may be
EV X4E5 Balance Nitrogen 24 Corrosive
available, please inquire.
> 300 ppm Carbon Dioxide,
9. Protocol mixtures should not > 4 ppm Nitric Oxide, 40 to 499 ppm Sulfur Dioxide
be used below 150 psig. EV X4E5 Balance Nitrogen 24 Corrosive
> 300 ppm Carbon Dioxide,
> 4 ppm Nitric Oxide, 10 to 39 ppm Sulfur Dioxide
EV X4E5 Balance Nitrogen 6 Corrosive
> 300 ppm Carbon Dioxide,
These mixtures are > 0.8% Oxygen, > 1 ppm Propane
available as EV X4E6 Balance Nitrogen 36 Non-Corrosive
Benchmark Standards,
at the exact > 300 ppm Carbon Dioxide,
concentration you > 0.8% Oxygen, > 500 ppm Sulfur Dioxide
ordered!! EV X4E7 Balance Nitrogen 36 Corrosive
> 8 ppm Carbon Monoxide,
> 0.8% Oxygen, > 1 ppm Propane
EV X4E8 Balance Nitrogen 36 Non-Corrosive
E
12

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-12

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/06-16 5/27/03 5:33 PM Page 13

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


ENVIRONMENTAL
OTHER MIXTURE GRADES

Primary Master, Dynamic- ■ Dynamic-Blend Standard Our worldwide ISO 9000 and Guide 25
These mixtures are prepared similarly to certified facilities and Declaration of
Blend Master, Benchmark
the Dynamic Blend Master. Certification Equivalence agreements between NIST, EPA,
Standards, Certified of the mixtures is based on process NMi and other metrology laboratories
Standards accuracy and Praxair Primary Laboratory ensure many Praxair mixtures are traceable
Standards (PPLS). internationally and all are consistent
These mixtures are precisely blended and wherever they are produced.
certified in Praxair’s Specialty Gases ■ Certified Standards
laboratories for CEM or other emission Environmental Calibration products are
These routine calibration mixtures are
measurements. Analytical certification of 1%,
prepared by either gravimetric, volumetric available in any of the previously stated
2% or 5% uncertainty is available. NIST
or partial pressure methods. Gravimetric, grades. Simply add your desired grade.
traceability is available for most mixtures.
EPA Protocols and I/M Standards are also volumetric or partial pressure mixtures are
available in the following Praxair grade analyzed against Praxair Primary
categories. When placing your order, simply Laboratory Standards (PPLS) or NIST
specify the desired mixture, the desired cylinder traceable reference materials.
style and the grade that best suits your
certification needs. ■ Benchmark Standards Minor components
These mixtures are produced on Praxair’s such as Ammonia and
■ Primary Master dynamic blending system or Hydrogen Chloride are
High accuracy mixtures prepared gravimetricaly to match the nominal available upon
gravimetrically on electronic high concentration you ordered. We provide request.
precision balance. These standards are replacement mixtures that are the same
traceable to NIST SRMs or NTRMs. concentration as the one previously
Y M
ordered. Y M
LITHO PREP LITHO PREP

C K C K

Environmental Products Cylinder Table


CYLINDER PRESSURE VOLUME
ir STYLE psig kPa ft 3
m3
Praxa e!!
lus iv
Exc eactive
r s
Many nt mixture n AS 2000 13800 145 4.11
p o n e ble i
com w availa ed
are nosteel® treat AQ 2000 13800 78 2.21
Silco inders for e
cyl lum
a xim um voity. A3 2000 13800 29 0.82
m tabil
and s
T 2640 18200 314 8.89

K 2200 15200 236 6.68

D7 260 1800 8.5 0.24

Note: Nominal contents. Actual volume may vary due to component and/or concentration.
Please inquire about other cylinder sizes.

E
13

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-13

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/06-16 5/27/03 5:33 PM Page 14

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


ENVIRONMENTAL
MOBILE SOURCE EMISSIONS

Regulator Recommendations
Mobile Source Emissions Part No. I/M Mixture See Reference Guide
(Section F, Page 2)
Standards
EV MSE1 BAR-74/80 400 SERIES : Non-corrosive
With the increasing need to reduce mobile 3000 ppm Propane CGA 350
source emissions, Federal, Provincial and 8.0% Carbon Monoxide
State environmental agencies continue to Balance Nitrogen
promulgate vehicle emission reduction EV MSE2 BAR-74/80 with Carbon Dioxide 400 SERIES : Non-corrosive
legislation and testing programs. This 3000 ppm Propane CGA 350
legislation affects both vehicle manufacturers 8.0% Carbon Monoxide
and post production emissions programs 11.0% Carbon Dioxide
known as Inspection and Maintenance testing. Balance Nitrogen
EV MSE3 Low Range BAR-84 400 SERIES : Non-corrosive
Praxair offers a broad range of vehicle 600 ppm Propane CGA 350
emission calibration standards in high 1.6 % Carbon Monoxide
pressure aluminum and steel cylinders and in 11.0% Carbon Dioxide
Balance Nitrogen
one fill, low pressure transportable cylinders.
Praxair’s dynamic blending capabilities EV MSE4 Low Range BAR-90 - ET 400 SERIES : Non-corrosive
enable the production of “identical” gas 300 ppm Propane CGA 350
mixtures in as many separate cylinders as 1.0% Carbon Monoxide
6.0% Carbon Dioxide
required. Balance Nitrogen
These products are blended and certified EV MSE5 Mid-Range BAR-90 - ET 400 SERIES : Non-corrosive
1200 ppm Propane CGA 350
according to the latest EPA (e.g., I/M 240) 4.0% Carbon Monoxide
and California Bureau of Automotive Repair 12.0% Carbon Dioxide
(BAR) methodology and specifications. Balance Nitrogen
Praxair is an approved manufacturer of “BAR EV MSE6 Loaded Mode BAR-90 400 SERIES : Corrosive
Mixtures” in both high pressure and low Low Range CGA 660
pressure cylinders. 1000 ppm Nitric Oxide
M M
Y
Balance Nitrogen Y

Mobile Source Products — NIST Traceable


LITHO PREP LITHO PREP

C K EV MSE7 Loaded Mode BAR-90 400 SERIES : Corrosive C K


Mixtures to meet California’s BAR -74, -80, Mid Range CGA 660
-84, -90, -97 specifications. These 3000 ppm Nitric Oxide
mixtures contain Carbon Monoxide, Balance Nitrogen
Carbon Dioxide, Propane, and Nitric EV MSE8 Low Range BAR-97 400 SERIES : Non-corrosive
Oxide in high and low pressure 200 ppm Propane CGA 350
cylinders. 0.50% Carbon Monoxide
6.0% Carbon Dioxide
Balance Nitrogen
EV MSE9 Low Range BAR-97 with Nitric Oxide 400 SERIES : Corrosive
Reminders 200 ppm Propane CGA 660
0.50 % Carbon Monoxide
6.0 % Carbon Dioxide
1. Both 1 % and 2 % analytical accuracy mixtures 300 ppm Nitric Oxide
available. Balance Nitrogen
EV MSE10 BAR-97 Low Range NO 400 SERIES : Corrosive
2. BAR-74, -80, -84, -90ET Blend Tolerance: 300 ppm Nitric Oxide CGA 660
Zero blend tolerance Balance Nitrogen
BAR-97 Blend Tolerance: ± 2% blend EV MSE11 High Range BAR-97 400 SERIES : Non-corrosive
tolerance for both audit and calibration (span) gases. 3200 ppm Propane CGA 350
BAR-74, -80, -84, -90ET Analytical Accuracy: 8.0% Carbon Monoxide
Naming error shall not exceed ±2% of nominal 12.0% Carbon Dioxide
Balance Nitrogen
value for calibration (span) gases; ±1% of nominal
value for audit gas blends. EV MSE12 High Range BAR-97 with Nitric Oxide 400 SERIES : Corrosive
3200 ppm Propane CGA 660
BAR-97 Analytical Accuracy: Naming error shall 8.0 % Carbon Monoxide
not exceed ±1% of label value for calibration (span) 12.0 % Carbon Dioxide
gases; ±1% of label value for audit gas blends. 3000 ppm Nitric Oxide
Balance Nitrogen
Reduced pressure and volume may EV MSE13 BAR-97 High Range NO 400 SERIES : Corrosive
apply to certain mixture concentrations. 3000 ppm Nitric Oxide CGA 660
Balance Nitrogen
Other vehicle emission mixtures and BAR Audit EV MSE14 BAR-97 Zero Air 400 SERIES : Corrosive
gas mixtures are also available, please < 1 ppm THC CGA 590
< 1 ppm Carbon Monoxide
inquire. < 1 ppm Carbon Dioxide*
< 1 ppm Nitric Oxide
(Note: BAR 97 Audit Zero gas specifies < 1 ppm 20.9% Oxygen ±1%
Carbon Dioxide) Many mixtures
Balance Nitrogen
are now available as
*Available with 400 ppm CO2 on request. ISO Guide 25 compliant from
E our worldwide certified
facilities
14

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-14

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/06-16 5/27/03 5:34 PM Page 15

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


ENVIRONMENTAL
SUPERCRITICAL FLUID PRODUCTS

Supercritical Fluids for SFC and SFE products available include: SFE Mixtures
Chromatography and
Extraction ■ Ammonia SFE mixtures containing modifiers and
■ Carbon Dioxide additives can be produced by Praxair. By
Praxair is the world leader in the production of adding organic solvents, the chemical
■ Nitrous Oxide
Carbon Dioxide and its many applications. We properties of the extraction medium in the SFE
■ Sulfur Hexafluoride
supply various liquified gases for use as mobile fluid can be adjusted. Both polar and non-
phases in Supercritical Fluid Chromatography ■ Sulfur Dioxide polar materials can be added to the base SFE
(SFC) and as solvents in Supercritical Fluid ■ Xenon material. Although modifiers can be added
Extraction (SFE) techniques. through pump additions at the instrument,
NOTE: This product is normally supplied with direct blending with the supercritical base
We begin with the highest purity source materials
eductor tube and can be supplied with a material is preferred because it provides the
and then use purification and distillation process
greatest consistency. Modifier concentration
steps to remove impurities, including head space helium pad of up to 2000 psig.
particulates. Each cylinder conforms to Praxair will be based on solubility of the organic at
purity specifications and is produced through standard temperature and pressure
Specially cleaned gas handling equipment is conditions.
documented process control methodology. This
ensures that customers receive ultra pure, available.
consistent products for chromatography and We are constantly developing new mixtures
extraction applications. based on customer inquiries. Please contact
your local Praxair technical sales
representative to discuss your specific needs.
Y M Y M
LITHO PREP LITHO PREP

C K C K

Product and Package Information—Carbon Dioxide


REGULATOR RECOMMENDATIONS
PART No. PRODUCT QUALITY CYLINDER CONTENT SEE REFERENCE GUIDE
GRADE ASSAY / SPECIFICATION STYLE lb / kg (SECTION F, PAGE 2)
CD 4.8SE 4.8 99.998% AS 39 / 17.73 SFE Kit (see page F69)
SUPERCRITICAL O2 < 2 ppm
FLUID H2O < 0.5 ppm
EXTRACTION N2 < 5 ppm
H2 < 0.1 ppm
CO < 0.1 ppm
THC (as CH4) < 2 ppm
Total Extractable Hydrocarbons < 10 ppb
(as Dodecane)
Total Extractable Halocarbons < 100 ppt
(as CCL4)

CD 4.5SC 4.5 99.995% AS 39 / 17.73 SFC Kit (see page F69)


SUPERCRITICAL O2 < 5 ppm
FLUID H2O < 1 ppm
CHROMATOGRAPHY N2 < 10 ppm
H2 < 0.1 ppm
CO < 0.1 ppm
THC (as CH4) < 2 ppm
Total Extractable Hydrocarbons < 50 ppb
(as Dodecane)

E
15

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-15

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/06-16 5/27/03 5:34 PM Page 16

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


ENVIRONMENTAL
VOC STANDARDS

VOC Standards for Volatile Component Name Alternative Name


1,2,4-Trichlorobenzene
Organic Testing
Benzyl chloride Alpha-chlorotoluene
As part of the ongoing environmental 1,2-Dichlorobenzene o-Dichlorobenzene
enhancement programs driven by the Clean Hexachloro-1,3-butadiene
1,4-Dichlorobenzene p-Dichlorobenzene
Air Act Amendments, Volatile Organic
1,2,4-Trimethylbenzene Pseudocumene
Compound (VOC) measurements in air, soil
1,3-Dichlorobenzene m-Dichlorobenzene
and water are increasingly important. 1,3,5-Trimethylbenzene Mesitylene
EPA programs concerning Hazardous Air 4-Ethyltoluene
Pollutants (HAPs), Compliance Assurance 1,1,2,2-Tetrachloroethane
Monitoring (CAMs), EPA methods TO-14 and Ethylbenzene
15, and local, state and provincial programs Styrene Vinyl benzene
are demanding industry to measure an o-Xylene
increasing number of compounds at lower m-Xylene
concentration. p-Xylene
Chlorobenzene
Praxair offers a comprehensive list of 1,3-Dichloropropene (isomers)
Toluene
certified components used to calibrate gas
1,2-Dichloropropane
chromatographs, gas chromatograph-mass
1,2-Dibromoethane
spectrometers (GC-MS) and Fourier Transform Trichloroethylene 1,1,2-Trichloroethylene
Infrared Spectrometers. Our Micro-Blend 1,2-Dichloroethane Ethylene dichloride
Mixtures are prepared using micro-balance Benzene
Y M
LITHO PREP
gravimetric capillary injection methods into Carbon Tetrachloride Tetrachloromethane
Y M
LITHO PREP

C K cylinders that have undergone Praxair’s 1,1,1- Trichloroethane Methyl chloroform C K

proprietary cylinder treatment processes. Chloroform Trichloromethane


The components are then certified by Mass cis-1,2-Dichloroethylene
Spec and GC analytical techniques. 1,1-Dichloroethane Ethylidene chloride
1,1,2-Trichloro, 1,2,2 trifluoroethane Halocarbon-113
Praxair also provides certified VOC 3-Chloropropene
Methylene chloride Dichloromethane
Zero gases and the appropriate gas
1,1-Dichloroethylene Vinylidene chloride
handling and delivery equipment.
Methyl bromide Bromomethane
Trichlorofluoromethane Halocarbon-11
Ethyl chloride Chloroethane
Methyl chloride Chloromethane
Vinyl chloride
Dichlorodifluoromethane Halocarbon-12
N,N-Dimethylformamide
n-Butanol
Methyl isobutyl ketone 4-Methyl-2 pentanone
2-Methoxyethanol
Isopropanol 2-Propanol
Ethanol Ethyl alcohol
Acetonitrile
1,2-Dichlorotetrafluoroethane Halocarbon-114
Ethyl acetate
Methyl ethyl ketone 2-Butanone
Methanol Methyl alcohol
Acetone
Hexane
Pentane
Acrylonitrile
2-Hexanone
Diethyl ether

E
16

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-16

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/17-19 5/27/03 5:37 PM Page 17

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


PETROCHEMICAL
GENERAL

Hydrocarbon Processing Pure Organic Products


Industry Products The Pure Gases section (pages C1 to C80), include a wide range of pure organic products.
Praxair provides a wide range of both pure Praxair’s extensive supplier network provides access to a wide range of raw materials.
organics and mixtures in many container types These raw materials often have more stringent specifications than other commercially
and sizes. Our specialty gases production available materials. In-house proprietary purification is used in cases where higher
facilities provide products for natural gas, specifications are required.
petrochemical and petroleum related products.
Common High Purity Organics Available
CHEMICAL GRADE QUALITY PAGE NO. (SECTION C)
1, 3 Butadiene 2.8 99.8% C10
n-Butane 3.0 99.9% C11
1-Butene 3.0 99.9% C12
Dimethyl Ether 2.5 99.5% C22
Dimethylamine 2.0 99.0% C23
Ethane 5.0 99.999% C25
Ethyl Chloride 3.0 99.9% C26
Ethylene 5.0 99.999% C27
Halocarbon-22 3.0 99.9% C30
Halocarbon-134A 2.8 99.8% C33
Isobutane 4.0 99.99% C43
Methane 5.0 99.999% C46

Mixtures
The Hydrocarbon Processing Industry (HPI) is unique in the type of products it requires.
Y M
LITHO PREP
Mixtures are no exception. To effectively service the market Praxair brings the following: Y M
LITHO PREP

C K
■ 25 years of manufacturing expertise ■ Highly trained sales and customer C K

■ Wide range of containers service personnel


■ Inventory of hundreds of assayed ■ Three centers of excellence
chemicals Geismar, Louisiana (U.S.)
■ Dedicated analytical instrumentation Edmonton, Alberta (Canada)
■ Computerized phase behavior Mexico City (Mexico)
evaluation ■ 600 Distribution centers for better
■ Industry wide association interface service
■ Market driven product lines ■ Wide range of products

Manufacturing Experience Containers Inventory of Assayed


Since complex hydrocarbon mixtures are Pages B1 to B8 show most of the available Chemicals
purchased infrequently, in many cases once containers. Several other containers are To effectively respond to your custom needs
every 1-2 years, it is very important to have available: Piston cylinders, see page 19 of we carry over 200 assayed chemicals in our
good documentation of the manufacturing this section for more details on these highly inventory at our centers of excellence.
process and experienced chemists and specialized containers which have working Assaying raw materials is critical to product
technicians. Precise and accurate mixtures pressures of 2000 psi. Praxair can offer quality. Many mixtures are used to calibrate
are dependent on good engineering some liquid mixtures in both aluminum analyzers that function to assay the same
principles and operator techniques. cylinders (4L, 2 L, 1 L, 500 ml, 250 ml) as chemicals as the matrix of the standard.
well as glass ampules. Glass ampules Therefore quantifying impurities is most
range in size of (100 ml, 20 ml, 10 ml, 5 important. At Praxair, assaying practices of
ut ml, and 2 ml). These containers are raw materials is a highly controlled process,
e abo of
Inquir ne effective in maintaining the integrity of with well defined specifications. In some
ir ’s li s
Praxa ® treated ga complex matrices over extended periods. cases we purify our starting materials to
s te el ne nts We continually look for new packaging ensure our final product quality and
Silco c o m po
in g 7 )
6 techniques to enhance our hydrocarbon
handl ages F75-F
minimize errors.
p products. Please call us with your special
(see packaging requests.

E
17

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-17

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/17-19 5/27/03 5:37 PM Page 18

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


PETROCHEMICAL
MIXTURES

Typical Natural Gas Reference Standards


Part No. PC NG1 PC NG2 PC NG3 PC NG4 PC NG5 Industry Wide Association
Component Interface
Concentration GPA Gas High Helium High Ethane Low BTU Daniel Most customers have individual needs. But
(Mol %) Reference Reference Reference Reference Mixture in some cases problems are evaluated and
Helium 0.5 0.2-2.0 ---- ---- ---- resolved under the umbrella of a trade or
Hydrogen ---- ---- ---- 14.0 ---- industry wide association. Praxair works
Argon ---- ---- ---- 1.0 ---- with many of these organizations including
Nitrogen 5.0 1.6 2.5 Balance 2.5 ASTM D-2, D-3; GPA, WSPA and API.
Carbon Monoxide ---- ---- ---- 12.0 ----
Carbon Dioxide 1.0 0.3 3.0 5.0 1.0
Methane Balance Balance Balance 0.5 89.57
Ethane 9.0 3.0 3.5 ---- 5.0
Acetylene ---- ---- ---- 1.0 ----
Propane 6.0 1.8 1.0 ---- 1.0
Isobutane 3.0 1.0 0.4 ---- 0.3
n-Butane 3.0 1.0 0.4 ---- 0.3
Isopentane 1.0 0.3 0.15 ---- 0.1
n-Pentane 1.0 0.3 0.15 ---- 0.1
Neopentane ---- ---- 0.1 ---- 0.1
n-Hexane ---- ---- 0.05 ---- 0.03
n-Heptane ---- ---- 0.02 ---- ----

Dedicated Analytical Computerized Phase Knowledgeable Sales and


Y M Instrumentation. Behavior Evaluation. Customer Service Personnel. Y M
LITHO PREP
LITHO PREP

C K Two variables are critical to ensure the Mixtures containing large amounts of The technical complexity of these products C K

reliability of measurements over extended organic components are susceptible to require a knowledgeable, effective sales
times. The variables are the primary nonideal physical behavior. This nonideal and customer service team. Praxair’s
standards used and the analytical behavior can be effectively computer centers of excellence in the U.S., Canada
instrumentation. Whenever feasible, Praxair modeled. These simulations enable Praxair and Mexico provide quick responses to your
uses the same analytical methods used in personnel to predict the temperature and the request for products and services.
your industry. This practice reduces the pressure at which a mixture will turn from a
introduction of bias to our measurements single phase system to a nonhomogeneous
and increases confidence in analytical two phase system. With this information
results. In many cases we will work with Praxair can prepare complex mixtures with
our customers to duplicate their analytical confidence that the system will remain
processes in our laboratories. Non- homogeneous at pre-established
disclosure agreements are arranged when temperatures.
required.

Typical Petrochemical Mixtures


Compounds Concentration Compounds Concentration Compounds Concentration Compounds Concentration
(v/v) (v/v) (w/w%) (w/w%)
Methane 10 ppm Methane 100 ppm Propane 20 ppm Methyl Chloride 100 ppm
Ethane 200 ppm Ethane 500 ppm Propylene 10 ppm Ethyl Chloride 500 ppm
Propane 5000 ppm Acetylene 5 ppm Isobutylene 200 ppm Vinyl Acetylene 10 ppm
Isobutane 50 ppm Propane 5 ppm Isobutane 100 ppm Ethylene 100 ppm
n-Butane 50 ppm Propylene 10 ppm 1 - Butene 500 ppm Ethane 10 ppm
1 - Butene 10 ppm Carbon Monoxide 2 ppm 2 - Butene 500 ppm Vinyl Chloride Balance
2 - Butene 10 ppm Carbon Dioxide 2 ppm Propadiene 10 ppm
Propadiene 5 ppm Isobutane 5 ppm 1,2 - Butadiene 50 ppm
Vinyl Acetylene 5 ppm n-Butane 5 ppm Butadiene Dimer < 100 ppm
Propyne 5 ppm Methanol 10 ppm TBC 120 ppm
Propylene Balance Ethylene Balance 1,3 - Butadiene Balance

E
18

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-18

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/17-19 5/27/03 5:37 PM Page 19

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


PETROCHEMICAL
MIXTURES

Three Centers of Excellence. Typical Liquid Mixtures


To effectively service North America Praxair C5
D-3710
has three centers of excellence for
hydrocarbons. These centers are located in Liquid Calibration Mixture Liquid Calibration Mixture
Geismar, Louisiana; Edmonton, Alberta, Compounds Concentration Compounds Concentration
Canada; and Mexico City, Mexico. (LV%) (w/w%)
Each of these centers have advanced Propane 1.0
cylinder treatment capabilities, state of
3-Methyl 1-butene 5.5
Isobutane 3.0
the art gravimetric systems, and analytical 1-Pentene 7.5
n-Butane 10.0
equipment to effectively service the HPI 2-Pentene 7.5
Isopentane 9.0
market. They are supported by specialty 2-Methyl 1-butene 12.5
gases experts who are actively involved in
n-Pentane 7.0
2-Methyl 2-butene 12.5
the HPI market. Other support comes from 2-Methylpentane 5.0
Isoprene 50 ppm
Praxair R&D, where teams of scientists are n-Hexane 5.0
1,3 - Pentadienes 100 ppm
dedicated to the development of specialty 2,4-Dimethylpentane 5.0
Cyclopentene 5.0
gas products and services. n-Heptane 9.0
Cyclopentane 5.0
Toluene 10.0
n-Pentane 19.5
Over 600 Distribution Centers n-Octane 5.0
Isopentane 25.0
For Better Service. p-Xylene 12.0
Praxair’s North American network of 17 n-Propylbenzene 3.0
specialty gas production facilities and over n-Decane 3.0
Welker
Y M
600 distribution centers means better service n-Butylbenzene 3.0 Y M
LITHO PREP
Piston LITHO PREP

C K for our customers. Most customers receive n-Dodecane 3.0 C K

deliveries via Praxair trucks, which means n-Tridecane 2.0 Cylinder


better service at lower costs. n-Tetradecane 2.0
n-Pentadecane 2.0
Wide Range of Products
Praxair is your one-stop shop for specialty
gases. Industry Wide Standards
These standards are developed in
■ Trace oxygenates in hydrocarbon association with industry wide organizations
matrices to provide uniform measurements across an
■ Trace sulfurs in hydrocarbon industry. These standards address a specific
matrices (gas, liquefied, liquid) constituent, multiple numbers of constituents,
■ Trace chlorides and fluorides in or groups of constituents. In many cases,
hydrocarbon matrices (gas, these standards are the benchmark when no
liquefied, liquid) primary standards are available through
■ Trace PH3, AsH3 in ethylene government organizations. For more details
■ Trace atmospherics (O2, N2, CO, contact your Praxair representative.

CO2, H2) in hydrocarbon matrices


■ Trace organic impurities in major State of the Art Mixtures
commodity organics (ethylene, Praxair manufactures some mixtures that
propylene, etc.) have very stringent specifications. Mixtures
■ Ethylene cracker optimization with accuracies as tight as +0.25% can be
mixtures generated.
■ Change of custody standards for
olefins, paraffins, halocarbons, These mixtures are provided with a detailed
oxygenates, aromatics. report fully documenting all aspects of the
■ ASTM mixtures such as D-2887, D- manufacturing and certification process. For
more details on these products, please
3710, D-4815, D-5453, etc.
contact your Praxair representative.
■ High accuracy B.T.U. standards
(+/- 1 B.T.U. )
■ Extended B.T.U. analysis
E
standards 19

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-19

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/20-22 5/27/03 6:08 PM Page 20

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


INDUSTRIAL HYGIENE
GENERAL

The Praxair Solution The Applications The Products


The Praxair solution is to provide a calibration ■ Workplace Air Monitoring ■ Calibration Standards
and delivery system which ensures the
reliability of your monitoring processes. ■ Confined Space Entry ■ Zero Gases
■ Medical Stations ■ Emergency Oxygen Kits
Praxair has collaborated with industry,
■ Emergency Response Kits
regulatory agencies, and instrument
manufacturers to ensure you receive a creative
and cost effective system, which provides Praxair’s Portable Cylinders are Offered in Different Sizes
accurate and reliable calibration products.
Within Two Portable Packaging Options (see page B8 for details)
■ Non-refillable Cylinders
58 Liter Cylinders (D3 style) for Reactive Gases
17 liters (D1 style), 103 liters (D2 style) and 226 liters (D7 style) cylinders
for Non-Reactive Gases
■ Refillable
248 Liter Cylinders (TC style) for Non-Reactive Gases
682 Liter Cylinders (TE style) for Emergency Oxygen Kits
■ Your choice of other Praxair cylinder styles available
Y M
for all products upon request. Y M
LITHO PREP LITHO PREP

C K C K
NON-REFILLABLE CYLINDERS

Reactive Gas Mixtures


The 58 liter cylinder is manufactured of aluminum Cylinder Content Pressure Dimensions (Inches) Material Recommended DOT Outlet
Size (ft3) (psig) Length OD Regulator Specification Fitting
and is recommended for mixtures that are not
stable in steel cylinders. These include Hydrogen
58 liter 2.0 500 14-1/2” 3-1/2” aluminum 511, 512, 514, 39 NRC 5/8”-18 UNF
Sulfide, Sulfur Dioxide, Nitrogen Dioxide, Nitric 515, 516, 517, 518
Oxide and Ammonia.
Gas mixtures in Nitrogen are certified to an NOTE: Gas mixtures for reactive gases with air are certified to an analytical accuracy of + 10% of the minor components.
analytical accuracy as follows:
5 - 24 ppm +10% of the minor components
25 - 300 ppm +5% of the minor components
Part No. Product Description Part No. Product Description
Acrylonitrile Hydrogen Sulfide (continued)
IH AIAN1 1-100 ppm/Air or Nitrogen (IH NIAN1) IH HS9 25 ppm/Propane 25% LEL (0.55%)/Carbon Monoxide
50 ppm/Oxygen 19%/Nitrogen
Ammonia IH HS10 25 ppm/Propane 25% LEL (0.55%)/Carbon Monoxide
IH AIAM1 10 ppm/Air or Nitrogen (IH NIAM1) 50 ppm/Air
IH AIAM2 25 ppm/Air or Nitrogen (IH NIAM2) IH HS11 25 ppm/Propane 50% LEL (0.55%)/Carbon Monoxide
IH AIAM3 50 ppm/Air or Nitrogen (IH NIAM3) 50 ppm/Oxygen 19%/Nitrogen
IH HS12 25 ppm/Methane 50% LEL (2.5%)/Carbon Monoxide
Hydrogen Sulfide 50 ppm/Oxygen 19%/Nitrogen
IH AIHS1 10-100 ppm/Air or Nitrogen (IH NIHS1)
IH HS13 25 ppm/Methane 50% LEL (2.5%)/Carbon Monoxide 50 ppm/Air
IH HS2 25 ppm/Propane 25 % LEL (0.55%)/Air
IH HS14 25 ppm/Pentane 50% LEL (0.70%)/Carbon Monoxide
IH HS3 25 ppm/Propane 25 % LEL (0.55%)/Oxygen 19%/Nitrogen 50 ppm/Oxygen 19%/Nitrogen
IH HS4 25 ppm/Propane 50% LEL (1.05%)/Air IH HS15 25 ppm/Pentane 25% LEL (0.35%)/Carbon Monoxide
IH HS5 25 ppm/Propane 50% LEL (1.05%)/Oxygen 19%/Nitrogen 50 ppm/Air
IH HS6 25 ppm/Pentane 25 % LEL (0.35%)/Oxygen 19%/Nitrogen IH HS16 25 ppm/Methane 50% LEL (2.5%)/Carbon Monoxide
IH HS7 25 ppm/Pentane 25% LEL (0.35%)/Air 100 ppm/Air
IH HS8 25 ppm/Methane 50% LEL (2.5%)/Oxygen 19%/Nitrogen IH HS17 25 ppm/Pentane 30% LEL (0.42%)/Carbon Monoxide
25 ppm/Methane 50% LEL (2.5%)/Air 100 ppm /Air
E
20

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-20

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/20-22 5/27/03 6:08 PM Page 21

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


INDUSTRIAL HYGIENE
NON-REFILLABLE CYLINDERS

Reactive Gas Mixtures (continued)


PART NO. PRODUCT DESCRIPTION PART NO. PRODUCT DESCRIPTION

Methylene Chloride Perchloroethylene


IH AIMCX 1-500 ppm/Air or Nitrogen (IH NIMCX) IH AIPC 1-100 ppm/Air or Nitrogen (IH NIPCX)

Nitric Oxide Sulfur Dioxide


IH NO1 5 ppm/Nitrogen IH AISD 5-10 ppm/Air or Nitrogen (IH NISDX)
IH NO2 10 ppm/Nitrogen IH SD2 25 ppm/Nitrogen
IH NO3 25 ppm/Nitrogen IH SD3 35 ppm/Nitrogen
IH NO4 30 ppm/Nitrogen
Vinyl Chloride
IH NO5 50 ppm/Nitrogen
IH AIVCX 1-3000 ppm/Air or Nitrogen (IH NIVCX)
Nitrogen Dioxide
IH N1 5 ppm/Nitrogen
IH N2 10 ppm/Nitrogen
IH N3 30 ppm/Nitrogen
IH N4 50 ppm/Nitrogen

Non-Reactive Gas Mixtures


The 17 liter cylinder is recommended for gas Cylinder Content Pressure Dimensions (Inches) Material Recommended DOT Outlet
mixtures where only a small quantity is required. Size (ft3) (psig) Length OD Regulator Specification Fitting
This includes LEL (Lower Explosive Limit), Carbon
Monoxide and other non-reactive mixtures. 17 liter 0.6 240 11” 2-7/8” steel 400,411, 413 39 NRC CGA
415, 416, 417,418 600
The 103 liter cylinder is recommended for non-
reactive gas mixtures and pure gases such as 103 liter 3.6 1000 13-27/32” 3-1/4” steel 511, 512, 39 NRC 5/8”-18
Y M Y M
LITHO PREP
Argon, Nitrogen, and Helium. This cylinder 514, 515, 516, UNF LITHO PREP

C K
combines a convenient size with enough 517, 518
C K

capacity to handle even your most rigorous


calibration requirements. 226 liter 8 260 16” 9” steel 400,411, 413 39 NRC CGA
The 226 liter cylinder is recommended for gas 415, 416, 417,418 165
mixtures when a large quantity is required. - Gas mixtures are certified to the following analytical accuracy:
10 ppm to 49 ppm +5% of the minor components
- 50 ppm to 50% +2% of the minor components
Gas mixtures for reactive gases with air are certified to an analytical accuracy of + 10% of the minor components.

PART NO. PRODUCT DESCRIPTION PART NO. PRODUCT DESCRIPTION PART NO. PRODUCT DESCRIPTION

IH AI1 Air–Zero Hydrogen Oxygen


IH HY1 25% LEL/Air (1.0%) IH OX1 19.5%/Nitrogen
IH AR1 Argon–Zero
IH HY2 40% LEL/Air (2.0%) IH OX2 20.9%/Nitrogen
Carbon Dioxide Pentane
IH CD1 1000 ppm/Nitrogen
Isobutylene
IH PT1 20% LEL (0.24%)/Air
IH IY1 100 ppm/Air
IH CD2 2000 ppm/Nitrogen IH PT2 50% LEL (0.70%)/Air
IH CD3 2.5%/Nitrogen Methane IH PT3 25% LEL (0.35%)/100 ppm Carbon Monoxide
IH CD4 5.0%/Nitrogen IH ME1 50 ppm/Air 19%Oxygen/Nitrogen
IH ME2 100 ppm/Air IH PT4
Carbon Monoxide 50% LEL (0.70%)/50 ppm Carbon Monoxide
IH ME3 500 ppm/Air 19%Oxygen/Nitrogen
IH AICO1 20-500 ppm/Air
IH ME4 1000 ppm/Air IH PT5 25% LEL (0.35%)/50 ppm Carbon Monoxide
or Nitrogen (IH NICO1)
IH ME5 20% LEL/Air (1.0%) 19%Oxygen/Nitrogen
IH CO2 50 ppm/ 2.5%Methane
IH ME6 45% LEL/Air (2.0%)
19%Oxygen/Nitrogen Propane
IH ME7 50% LEL/Air (2.5%)
IH CO3 100 ppm/ 2.5%Methane IH PR1 100 ppm/Nitrogen
IH ME8 2.5%Methane
17%Oxygen/Nitrogen IH PR2 25% LEL/Air (0.55%)
17%Oxygen/Nitrogen
IH CO4 200 ppm/ 2.5%Methane IH PR3 45% LEL/Air (1.0%)
19.5%Oxygen/Nitrogen n-Butane IH PR4 50% LEL/Air (1.10%)
IH BU1 25% LEL (0.45%)/Air (IH BU1)
Hexane Toluene
IH BU2 50% LEL (0.90%)/Air (IH BU2)
IH AIHX1 50-500 ppm/Air IH TL1 400 ppm/Air
or Nitrogen (IH NIHX1) IH NI1 Nitrogen–Zero
IH HX2 25% LEL (0.3%)/Air
Nitrous Oxide
IH NS1 10 ppm/Air E
IH NS2 25 ppm/Air
21

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-21

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/20-22 5/27/03 6:08 PM Page 22

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


INDUSTRIAL HYGIENE
REFILLABLE CYLINDERS

NOW!!
Specifications
THE EXCITING NEWS!! Cylinder Construction: Aluminum Alloy 6061-T6, Coated
INTRODUCING... with Heat Sensing Film CTC/DOT
A refillable, Lightweight 3AL, Burst Disk rating 3025/3360 psi
Aluminum Cylinder
with Revolutionary Working Pressure: 2015 psig @ 70 Deg. F
Regulator Design
Total System Weight:
TC (Calibration Cylinder) 6.32 lb (2.87 kg)
TE (Emergency Oxygen Cyl.) 10.5 lb (4.76 kg)
■ Calibration Gas Cylinder
Part No. WES 1000C Total System Dimensions:
TC (Calibration Cylinder) Length 17.845", OD 4.375"
TC TE TE (Emergency Oxygen Cyl.) Length 32.595" OD 4.375"
■ Emergency Oxygen Kit
Part No. WES 3000C Non-Reactive Mixtures
PART NO. PRODUCT DESCRIPTION PART NO. PRODUCT DESCRIPTION

This innovative design combines flow control, PP C1010C Methane PP C1030C Oxygen Deficiency
regulator, yoke and post valve into a single 25% LEL (1.25%)/Air 4% 02 / N2
unit that is easy to operate and easy to 50% LEL (2.5%)/Air 5% 02 / N2
transport. The incorporation of all these PP C1011C Ethane 19.5% 02 / N2
components within a durable, impact 25% LEL (0.75%)/Air 20.9% 02 /N2
resistant cover protects the unit and virtually 50% LEL (1.5%)/Air
Y M
Pure Zero Gases Y M

Propane
LITHO PREP LITHO PREP

C K eliminates breakage. The aesthetic design is PP C1012C C K

25% LEL (0.55%)/Air


PP C1040C Air
a prime example of form following function
50% LEL (1.10%)/Air Zero Gas
creating a user friendly system. A contoured Extra Dry
click -stop flow control knob operates the PP C1013C n-Butane
25% LEL (0.45%)/Air
PP C1042C Argon
entire system, and a built in handle allows it
50% LEL (0.90%)/Air 5.0 Zero Gas
to be picked up and transported for maximum
convenience. Experience the "Revolution in PP C1020C Carbon Monoxide PP C1041C Nitrogen
(Air Balance) 20-200 ppm/Air or N2 5.0 Zero Gas
Regulator Design."
PP C1021C PP C3010E Emergency 02 Kits
(Nitrogen Balance) Medical Oxygen - U.S.P.

Accessories Features Benefits


High Impact resistant cover/carry handle Virtually eliminates breakage (keeps unit damage free)
Carry Bags - custom designed for each portable
Convenient and safe to transport
size and application, convenient side pouch for
storing sample line and /or mask (re: EOK.) All in one design (Flow Control, Provides exceptional flow accuracy
Yoke & Post Valve, Regulator) Eliminates extra accessories (regulator/flowmeter/wrench)
Plastic sleeves are affixed to the bag allowing Minimize administration/ purchasing costs,
customer internal identification/labeling or delivers easy operation.
application information. Click-Stop Contoured Flow Knob Just Dial in flow rate assures precise flow rate
Part No. WES1001C (248 liter - TC style)
Lightweight aluminum (6lbs) Provides ease of handling/carrying
WES3001E (682 liter - TE style)
248 Liters (Calibration Cylinder) Increase number of calibrations (as compared to
Sample Lines - available for the calibration 682 Liters (EOK) disposable cylinders)
Approved standard size for all EOK applications
cylinder, 1/8" Tygon or Teflon tubing for
attachment to system outlet. Connections are Refillable Environmentally Friendly
No Hazardous Waste disposal issues
1/8" SwagelokTM fittings.
Part No. WES1005 High Quality Gas Products Guaranteed, Certified Gas Grades from Praxair,
Experienced, Quality Supplier

Cost Effective Value for your money

Aesthetically Pleasing Professional image for medical and calibration


service industry

E
22

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-22

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/23-25 5/27/03 6:09 PM Page 23

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


LASERS
MIXTURES

Praxair has been a leading supplier of Praxair also offers a full line of high
laser gas mixtures for many years. High purity gases which may be mixed through
quality gases improve laser performance a blender on site. Please contact your
and lower operating costs. Our complete Praxair representative for information on
laser gas product line is used in many pure gases and gas blending panels.
applications including healthcare, The following table contains the standard
industry and research. We can also offering of laser gas mixtures. Please call
provide an excellent assortment of if you require a mixture that is not listed
equipment options for your laser systems. here. Whatever your laser gas need,
Praxair has the solution for you!

Regulator Recommendations
Product Cylinder Content Pressure See Reference Guide
Part No. Description Style ft3 / m3 CGA psig/kPa (Section F, Page 2)

Carbon Dioxide Laser Mixtures:


CDLM 1:
LS CD1-T 1% to 20% Carbon Dioxide T 266 / 7.53 580 2400 / 16500 400 Series: Non-Corrosive
LS CD1-K 1% to 20% Nitrogen K 200 / 5.7 580 2000 / 13800 300 Series: Non-Corrosive
Balance Helium
Y M Y M
LITHO PREP

C K
CDLM 2: LITHO PREP

C K
LS CD2-T 0.5% to 10% Carbon Monoxide T 216 / 6.13 350 2000 / 13800 400 Series: Non-Corrosive
LS CD2-K 1% to 20% Carbon Dioxide K 193 / 5.5 350 1660 / 11445 300 Series: Non-Corrosive
1% to 25% Nitrogen
Balance Helium

CDLM 3:
LS CD3-T 1% to 10% Carbon Monoxide T 216 / 6.13 350 2000 / 13800 400 Series: Non-Corrosive
LS CD3-K 1% to 20% Carbon Dioxide K 193 / 5.5 350 1660 / 11445 300 Series: Non-Corrosive
0.1% to 10% Hydrogen
1% to 25% Nitrogen
Balance Helium

Coherent General CorporationTM


LS HECDNI1-T 4.5% Carbon Dioxide T 216 / 6.13 580 2400 / 16500 400 Series: Non-Corrosive
LS HECDNI1-K 13.5% Nitrogen K 193 / 5.5 580 2000 / 13800 300 Series: Non-Corrosive
Balance Helium

Coherent General CorporationTM


LS HECDCONI1-T 2% Carbon Monoxide T 216 / 6.13 350 2000 / 13800 400 Series: Non-Corrosive
LS HECDCONI1-K 6% Carbon Dioxide K 193 / 5.5 350 1660 / 11445 300 Series: Non-Corrosive
6% Nitrogen
Balance Helium

Lumonics LaserMark® 1
LS MARK1-T 2% Carbon Monoxide T 216 / 6.13 350 2000 / 13800 400 Series: Non-Corrosive
LS MARK1-K 8% Carbon Dioxide K 193 / 5.5 350 1660 / 11445 300 Series: Non-Corrosive
8% Nitrogen
Balance Helium

Also available in other cylinder types or concentrations.


Call your Praxair representative for package and supply information.

E
23

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-23

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/23-25 5/27/03 6:09 PM Page 24

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


LASERS
MIXTURES

Regulator Recommendations
Product Cylinder Content Pressure See Reference Guide
Part No. Description Style ft3/m3 CGA psig/kPa (Section F, Page 2)

Carbon Dioxide Laser Mixtures: (Continued)


Lumonics LaserMark® 2
LS MARK2-T 2% Carbon Monoxide T 216 / 6.13 350 2000 / 13800 400 Series: Non-Corrosive
LS MARK2-K 8% Carbon Dioxide K 193 / 5.5 350 1660 / 11445 300 Series: Non-Corrosive
16% Nitrogen
Balance Helium

Lumonics LaserMark® 3
LS MARK3-T 4% Carbon Monoxide T 216 / 6.13 350 2000 / 13800 400 Series: Non-Corrosive
LS MARK3-K 8% Carbon Dioxide K 193 / 5.5 350 1660 / 11445 300 Series: Non-Corrosive
8% Nitrogen
Balance Helium

Lumonics LaserMark® 4
LS MARK4-T 4% Carbon Monoxide T 216 / 6.13 350 2000 / 13800 400 Series: Non-Corrosive
LS MARK4-K 8% Carbon Dioxide K 193 / 5.5 350 1660 / 11445 300 Series: Non-Corrosive
16% Nitrogen
Balance Helium
Y M Y M
LITHO PREP Laser TechnicsTM LITHO PREP

C K
LS TECH1-T 0.4% Hydrogen T 216 / 6.13 350 2000 / 13800 400 Series: Non-Corrosive C K

LS TECH1-K 4% Carbon Monoxide K 193 / 5.5 350 1660 / 11445 300 Series: Non-Corrosive
8% Carbon Dioxide
8% Nitrogen
Balance Helium

Laser ElectronicsTM
LS EL1-T 0.4% Hydrogen T 216 / 6.13 350 2000 / 13800 400 Series: Non-Corrosive
LS EL1-K 4% Carbon Monoxide K 193 / 5.5 350 1660 / 11445 300 Series: Non-Corrosive
6% Carbon Dioxide
12% Nitrogen
Balance Helium

Sealed Tube Laser Mixtures:


STLM1
LS ST1 12.5% Normal Neon Call your Praxair representative for package and supply information
Balance Normal Helium

STLM2
LS ST2 12.5% Normal Neon Call your Praxair representative for package and supply information
Balance Isotope Helium-3

STLM3
LS ST3 12.5% Isotope Neon-20 Call your Praxair representative for package and supply information
Balance Normal Helium

STLM4
LS ST4 12.5% Isotope Neon-20 Call your Praxair representative for package and supply information
Balance Isotope Helium-3

E
24

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-24

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/23-25 5/27/03 6:09 PM Page 25

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


LASERS
MIXTURES

Regulator Recommendations
Product Cylinder Content Pressure See Reference Guide
Part No. Description Style ft3/m3 CGA psig/kPa (Section F, Page 2)

Mixtures for Excimer Laser:


ELM1
LS E1-UK 1% to 25% Argon UK 193 / 5.5 580 2000 / 13800 400 Series: Non-Corrosive
Balance Helium (316L SS) 300 Series: Non-Corrosive

ELM2
LS E2-UK 1% to 10% Xenon UK 193 / 5.5 580 2000 / 13800 400 Series: Non-Corrosive
Balance Helium (316L SS) 300 Series: Non-Corrosive

ELM3
LS E3-UK 150 PPM to 1500 PPM Hydrogen UK 193 / 5.5 350 2000 / 13800 400 Series: Non-Corrosive
Balance Helium 300 Series: Non-Corrosive

Fluorine Excimer Laser Mixtures:


FELM1
LS FE1 0.15% to 5% Fluorine Call your Praxair representative for package and supply information
Balance Helium, Argon or Neon
Y M Y M
LITHO PREP
FELM2 LITHO PREP

C K LS FE2 0.15% to 5% Fluorine Call your Praxair representative for package and supply information C K

10% to 20% Argon


Balance Helium

FELM3
LS FE3 0.1% to 0.5% Fluorine Call your Praxair representative for package and supply information
1% to 3% Krypton
Balance Helium

FELM4
LS FE4 0.2% to 0.3% Fluorine Call your Praxair representative for package and supply information
8% to 12% Argon
20% to 30% Neon
Balance Helium

Excimer Mixtures Containing Hydrogen Chloride:


HCLLM1
LS HCL1-NK 0.15% to 10% Hydrogen Chloride NK — 330 — 400 Series: Corrosive
LS HCL1-NQ Balance Helium NQ — 330 — 300 Series: Corrosive

HCLLM2
LS HCL2-NK 5% Hydrogen Chloride NK — 330 — 400 Series: Corrosive
1% Hydrogen NQ — 330 — 300 Series: Corrosive
Balance Helium or Neon

HCLLM3
(Lambda Physics)
LS HCL3-NK 0.075% to 0.15% Hydrogen Chloride NK — 330 — 400 Series: Corrosive
LS HCL3-NQ 0.015% to 0.03% Hydrogen NQ — 330 — 300 Series: Corrosive
0.65% to 2.1% Xenon
Balance Neon

E
25

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-25

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/26-28 5/27/03 6:11 PM Page 26

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


HEALTHCARE
MEDICAL GASES

SEE PURE GAS SECTION FOR MEDICAL AIR U.S.P.


TRANSPORT INFORMATION
CHEMICAL FORMULA: N/A
UNITED STATES OF AMERICA CANADA MEXICO

MEDICAL APPLICATIONS: Respiratory therapy;


Color Code: Black & White Shoulder Black & White Shoulder Black & White Shoulder humidity treatments using nebulizers.
Quandrants Quandrants

PART No. QUALITY CYLINDER CONTENT PRESSURE REGULATOR RECOMMENDATIONS


ASSAY/SPECIFICATION STYLE/CGA ft3 / m3 psig / kPa, gauge (SEE SECTION F PAGES F119-F125)

AI M-K U.S.P. 19.5 - 23.5% O2 K / 346 232 / 6.44 2200 / 15168 M1-346-P
AI M-E Balance N2, N.F. ME / 950 23 / 646L 2000 / 13790 M1-346-PG
AI M-D CO < 10 ppm MD / 950 14 / 387L 2000 / 13790 M1-346-FM
CO2 < 500 ppm M1-950-P
SO2 < 5 ppm M1-950-PG
NO + NO2 < 2.5 ppm M1-950-FM
Odor: None Note: All regulators above available in two-stage.
Condensed water and oil: None

Y M Y M
LITHO PREP LITHO PREP

C K C K

SEE PURE GAS SECTION FOR CARBON DIOXIDE U.S.P.


TRANSPORT INFORMATION
CHEMICAL FORMULA: CO2

MEDICAL APPLICATIONS: For close-to-physiologic


atmospheres for the operation of artificial organs; in
cryosurgery with insufflators during laparoscopic
Color Code: Gray Gray Shoulder Gray surgery; and as a component in a mixture of oxygen
or air as a respiratory stimulant to promote deep
breathing. Cylinders with a full length eductor tube to
permit withdrawal of liquid phase product are
available on request.

PART No. QUALITY CYLINDER CONTENT PRESSURE REGULATOR RECOMMENDATIONS


ASSAY/SPECIFICATION STYLE/CGA lb / kg psig / kPa, gauge (SEE SECTION F PAGES F119-F125)

CD M-K U.S.P. ≥ 99.0% CO2 K / 320 64 / 29.5 830 /5723 0109-75xx-320


CD M-E H2S < 1 ppm ME / 940 6.5 / 2.95 830 /5723 0109-75xx-940
CD M-D CO < 10 ppm MD / 940 4.0 / 1.81 830 /5723
NO < 2.5 ppm
NH3 < 25 ppm
SO2 < 5 ppm
H2O < 200 ppm
NO2 < 2.5 ppm

E See page C75 for liquid carbon dioxide.

26

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-26

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/26-28 5/27/03 6:11 PM Page 27

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


HEALTHCARE
MEDICAL GASES

SEE PURE GAS SECTION FOR HELIUM U.S.P.


TRANSPORT INFORMATION
CHEMICAL FORMULA: He
UNITED STATES OF AMERICA CANADA MEXICO

MEDICAL APPLICATIONS: As a component of


breathing mixtures to reduce the density of the
mixture and thus facilitate breathing under
Color Code: Brown Brown Shoulder Brown certain physical and physiological conditions.

REGULATOR RECOMMENDATIONS
PART No. QUALITY CYLINDER CONTENT PRESSURE REFERENCE GUIDE
ASSAY/SPECIFICATION STYLE/CGA ft / m psig / kPa, gauge (SEE SECTION F PAGES F119-F125)
3 3

HE M-K U.S.P. ≥ 99.0% He K / 580 218 / 6.04 2200 / 15168 109 SERIES: Non-Corrosive
HE M-E CO < 10ppm ME / 930 22 / 606 L 2000 / 13790
HE M-D Air ≤ 1.0% MD / 930 13 / 364 L 2000 / 13790
Odor --- None detected
Buoyancy --- Buoyant

See page C76 for cryogenic liquid helium.

Y M Y M
LITHO PREP

C K
SEE PURE GAS SECTION FOR NITROGEN N.F. LITHO PREP

C K
TRANSPORT INFORMATION
CHEMICAL FORMULA: N2
UNITED STATES OF AMERICA CANADA MEXICO

MEDICAL APPLICATIONS: As a component in


many gas mixtures; as a displacement medium
for sterile equipment; as a non-oxidizing dis-
Color Code: Black Black Shoulder Black placement medium in pharmaceutical vials; as
a propellant in pressurized aerosol type
dispensers; as a coolant for carbon dioxide
surgical lasers; and a source of pneumatic
pressure to power gas operated medical
devices.

REGULATOR RECOMMENDATIONS
PART No. QUALITY CYLINDER CONTENT PRESSURE REFERENCE GUIDE
ASSAY/SPECIFICATION STYLE/CGA ft / m psig / kPa, gauge (SEE SECTION F PAGES F119-F125)
3 3

NI M-T N.F. ≥ 99.0% N2 T / 580 304 / 8.43 2640 / 18202 109 SERIES : Non-Corrosive
NI M-K CO < 10 ppm K / 580 228 / 6.33 2200 / 15168
NI M-E O2 < 1.0% ME / 960 23 / 636 L 2000 / 13790
NI M-D Odor --- None detected MD / 960 14 / 381 L 2000 / 13790

NI 5.0M-T N.F. ≥ 99.999% N2 T / 580 304 / 8.43 2640 / 18202 300 SERIES : Non-Corrosive
NI 5.0M-K CO < 1 ppm K / 580 228 / 6.33 2200 / 15168
O2 < 1 ppm
Odor - None Detected

See page C77 for cryogenic liquid nitrogen.

E
27

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-27

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/26-28 5/27/03 6:11 PM Page 28

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


HEALTHCARE
MEDICAL GASES

SEE PURE GAS SECTION FOR NITROUS OXIDE U.S.P.


TRANSPORT INFORMATION CHEMICAL FORMULA: N2O
UNITED STATES OF AMERICA CANADA MEXICO

MEDICAL APPLICATIONS: As an analgesic,


often in combination with other agents for the
production of anesthesia. Nitrous Oxide is also
Color Code: Blue Blue Shoulder Blue used in cryosurgery.

REGULATOR RECOMMENDATIONS
PART No. QUALITY CYLINDER CONTENT PRESSURE REFERENCE GUIDE
ASSAY/SPECIFICATION STYLE/CGA lb / kg psig / kPa, gauge (SEE SECTION F PAGES F119-F125)
NS M-K U.S.P. ≥ 99.0% N2O K / 326 64 lb / 29.50 kg 745 / 5136 M2-326-P
NS M-S CO < 10ppm S / 326 31 lb / 14.00 kg 745 / 5136 M2-326-PG
NS M-E Air ≤ 1.0% ME / 910 6.4 lb / 2.90 kg 745 / 5136 M2-910-P
NS M-D CO2 < 300ppm MD / 910 3.9 lb / 1.78 kg 745 / 5136 M2-910-PG
NO < 1ppm Note: Above regulators also available in single stage.
NO2 < 1ppm
NH3 < 25ppm
Halogens < 1ppm
H2O < 200ppm

Y M Y M
LITHO PREP LITHO PREP

C K C K

SEE PURE GAS SECTION FOR OXYGEN U.S.P.


TRANSPORT INFORMATION
CHEMICAL FORMULA: O2
UNITED STATES OF AMERICA CANADA MEXICO

MEDICAL APPLICATIONS: Used in first-aid


treatment of emergencies such as suffocation
and heart attacks; in the treatment of patients
Color Code: Green White Shoulder Green with respiratory disorders; in anesthesia; and in
hyperbaric oxygen chambers for the treatment
of carbon monoxide poisoning and gas
gangrene; and for other specialized oxygen
therapies.

REGULATOR RECOMMENDATIONS
PART No. QUALITY CYLINDER CONTENT PRESSURE REFERENCE GUIDE
ASSAY/SPECIFICATION STYLE/CGA ft3 / m3 psig / kPa, gauge (SEE SECTION F PAGES F119-F125)
OX M-K U.S.P. ≥ 99.0% O2* K / 540 249 / 6.90 2200 / 14850 M1-540-P
OX M-S CO < 10ppm S / 540 154 / 4.28 2200 / 14850 M1-540-PG
OX M-Q CO2 < 300ppm Q / 540 83 / 2.31 2200 / 14850 M1-540-FG
OX M-E Odor --- None detected ME / 870 25 / 688 L 2000 / 13500 M1-540-FM
OX M-D MD / 870 15 / 413 L 2000/ 13500 M1-870-P
M1-870-PG
*Produced by air liquefaction. M1-870-FG
M1-870-FM
See page C78 for cryogenic liquid oxygen. Note: All regulators above available in two-stage.
E
28

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-28

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/29-30 5/27/03 6:14 PM Page 29

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


HEALTHCARE
MEDICAL MIXTURES

Praxair has been serving the Mixture Product Summary Gas Mixture Components
healthcare market for over 50 years. The following mixture product summary
represents the most common medical
for Medical Mixtures
Praxair has state of the art cylinder
mixtures and applications in the healthcare U.S.P. and N.F. Grades
filling and quality assurance facilities industry. Praxair can accommodate most
for the preparation of high purity gases customer requests and specialized needs. Air
and high accuracy mixtures for A physician’s independent and institutional N2 – Nitrogen (NF)
research diagnostics and inhalation review board approval is required for any CO2 – Carbon Dioxide
investigational mixture to be used in He – Helium
therapy applications. The products humans.
classified by Food and Drug N2O – Nitrous Oxide
In Canada, a physician must obtain
approval from the Special Access Program O2 – Oxygen
Administration (FDA–USA) and
of TPP in order for Praxair to supply gases Non-U.S.P. Grades
Therapeutic Products Programme to be used as drugs but have not been
(TPP–Canada) as drugs or devices are registered with a D.I.N. (Drug Identification C2H2 – Acetylene
produced in accordance with Good Number) CO – Carbon Monoxide
Manufacturing Practices (GMP). Accordingly preparation of specific mixtures H2 – Hydrogen
are subject to prior approval by Praxair. CH4 – Methane
Praxair facilities are audited both
Typical cylinder styles available: K, Q, ME Ne – Neon
internally and by the FDA. and MD. Contact your Praxair
representative for additional cylinder options Xe – Xenon
available in your area.

MINOR CONCENTRATION AND BALANCE GASES


Major Application and U.S.P./N.F. Grade Medical Components Other Components
Y M
Part No. Mixture Description Air CO2 He N2 N2O O2 CO Other Y M
LITHO PREP LITHO PREP

C K THERAPY GASES C K

Medical Drug Gases

General Medical Mixtures


MM OXCDC Carbon Dioxide/Oxygen 1-7% B
Heliox
MM HEOX20C 20% Oxygen/Helium B 20%
MM HEOX30C 30% Oxygen/Helium B 30%

DIAGNOSTIC GASES
Medical Device Gases
Praxair’s XeScan® Contrast
Enhancement Agent
OX MXE33C 33% Xenon/Oxygen B 33% Xe
Lung Diffusion for Pulmonary
Function Studies
LD AICO1C Carbon Monoxide/Air B 50-3000ppm
LD CO1 0.3% Carbon Monoxide, 10% Helium, 10% B 21% 0.3%
21% Oxygen/Nitrogen
LD NE1 0.3% Carbon Monoxide, 0.5% Neon, B 21% 0.3% 0.5% Ne
21% Oxygen/Nitrogen
LD ME1 0.3% Carbon Monoxide, 0.3% Methane, B 21% 0.3% 0.3% CH4
21% Oxygen/Nitrogen
LD AC1 0.3% Carbon Monoxide, 0.3% Acetylene, 10% B 21% 0.3% 0.3% C2H2
10% Helium, 21% Oxygen/Nitrogen
LD AC2 0.3% Carbon Monoxide, 0.3% Acetylene B 21% 0.3% 0.3% C2H2
0.3% Methane, 21% Oxygen/Nitrogen 0.3% CH4

Medical Laser Gas Mixtures


ML HE1 Carbon Dioxide, Nitrogen/Helium 1-20% B 1-20%
(See Page E23 For Specific Mixture Details)

For ordering purposes, please add the desired cylinder style to the end of the above part number.

Diagnostic gas mixtures are typically supplied as certified standards, but can be produced to meet primary standard grade.
For applications that do not require a reported analysis such as biological atmospheres and medical laser gases, non-certified grades
are provided. E
B=Balance Gas 29

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-29

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/29-30 5/27/03 6:14 PM Page 30

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


HEALTHCARE
MEDICAL MIXTURES

MINOR CONCENTRATION AND BALANCE GASES


U.S.P. Grade Medical Components Other Components
Part No. Major Application and Mixture Description CO2 He N2 O2 CO Other
DIAGNOSTIC GASES
Medical Device Gases

Blood Gas Analysis


BG OXCDX Carbon Dioxide/Oxygen 7-12% B
BG NICDX Carbon Dioxide/Nitrogen 2-14% B
BG NIOXX Oxygen/Nitrogen B 1-19%
BG NICDOXX Carbon Dioxide, Oxygen/Nitrogen 2-12% B 12-25%

Biological Incubation Atmospheres


Carbon Dioxide, Oxygen/Nitrogen 2-15% B 5-21%
Carbon Dioxide/Oxygen 5-10% B
Carbon Dioxide, Hydrogen/Nitrogen 5-10% B 5-10% H2
Hydrogen/Carbon Dioxide B 3-10% H2
(See Page E32 For Specific Mixture Details)

Canada - Registered Drugs U.S.P./N.F. Grade Medical Components Other Components


(Gas Mixtures) Air CO2 He N2 N2O O2 Xe CO Ne
Carbon Dioxide/Oxygen 1-50% B
Oxygen/Helium B 18-50%
Oxygen/Nitrogen B 23.5-50%
Oxygen/Xenon 30-35% B
Y M Liqui-Med Analgesic Gas (Oxygen/Nitrous Oxide) 50% 50% Y M
LITHO PREP LITHO PREP

C K Carbon Dioxide/Oxygen/Nitrogen 1-50% B 21% C K

Carbon Monoxide/Air B 50-3000ppm


Carbon Monoxide/Helium/Oxygen/Nitrogen 10% B 21% 0.1%-0.3%
Carbon Monoxide/Neon/Oxygen/Nitrogen B 21% 0.3% 0.5%

For ordering purposes, please add the desired cylinder style to the end of the above part number.
Diagnostic gas mixtures are typically supplied as certified standards, but can be produced to meet primary standard grade.
For applications that do not require a reported analysis such as biological atmospheres and medical laser gases, non-certified grades
are provided.
B=Balance Gas

Outlet Connections
Medical Gas Mixtures Cylinder Valve Yoke Threaded
Carbon Dioxide & Oxygen (CO2 not over 7%) 880 280
Carbon Dioxide & Oxygen (CO2 over 7%) 940 500
Carbon Dioxide, Oxygen, Nitrogen 973 500
Clinical Blood Gas Mixtures 973 500
Gas Mixtures, Medical* Flammable 981 350
Gas Mixtures, Medical* Nonflammable, Noncorrosive 973 500
Gas Mixtures, Medical* Nonflammable, Noncorrosive 985 580
Helium & Oxygen (He not over 80%) 890 280
Helium & Oxygen (He over 80%) 930 500
Lung Diffusion Mixtures 973 500
Nitric Oxide Mixtures and Nitrogen Dioxide Mixtures N/A 625
Nitrous Oxide & Oxygen (N2O 47.5 to 52.5%) 965 280
Nitrogen & Oxygen (O2 over 23.5%) 890 280
Oxidizing Mixtures 977 296
Xenon & Oxygen (O2 over 20%) 890 280
*Gas mixtures labeled as drugs or medical devices and not having another connection assignment.

E
30

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-30

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/31-32 5/27/03 6:15 PM Page 31

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


BIOTECHNOLOGY
GENERAL

Praxair offers a complete line of gases Gases And Related Products Documentation for
and related products to this fast
In addition to gas products, Praxair offers
Traceability/Certification
growing, exciting industry. Where
applicable, products are produced related products that include: Certificate of Compliance (COC1)
Document that delineates that a product
according to the U.S. Pharmacopoeia ■ Regulators General Purpose and
meets or exceeds the minimum purity or
(U.S.P.) and the National Formulary Ultra High Purity analytical accuracy as specified.
(N.F.) specifications and in accordance ■ Economical Manifolds for your Gas
Certificate of Conformance (COC2)
with Good Manufacturing Practices and Liquid Distribution Needs Statement of guarantee that the product from
■ Refrigerators, Freezers (including a specific batch conforms to the
(GMP). Production facilities are
Inventory Systems) components, minimum purity and maximum
audited by Praxair Quality Assurance ■ Cryogenic Transfer Hoses, Phase impurity specifications as listed.
teams and externally by the Food and Separators and Accessories Certificate of Analysis (COA)
Drug Administration (FDA) and the ■ Liquid Withdrawal Devices and Dippers A document that reports the actual analytical
Therapeutic Products Programme ■ Sample Storage Accessories test results for pure product or for a
calibration mixture. Either single cylinder or
(Canada). ■ Personal Safety Equipment
batch analysis certification is available.

For details, please see the Gas Handling


Available Upon Request!
Equipment Section (pages F88-F93) or
contact your Praxair representative.

Y M Y M
LITHO PREP LITHO PREP

C K C K

E
31

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-31

600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/31-32 5/27/03 6:15 PM Page 32

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


BIOTECHNOLOGY
PURE GASES AND MIXTURES

GAS PRODUCTS
Part No. Product Description Purity Cylinder CGA Contents Regulator Recommendations
Style ft3/m3 (See Section F Page 2)

MEDICAL DRUG GASES

Cryogenic Gases In Liquid


Containers

NI M Nitrogen N.F. Grade 99.0% 160L Gas-580 3690/102 206 SERIES: Special Purpose
(for more information see 180L Liquid-295 4110/114 Liquid Containers
Section C Page 77) 230L 5030/139

NI 5.0 M Nitrogen N.F. UHP Grade 99.999% 160L Gas-580 3690/102 206 SERIES: Special Purpose
(for more information see 180L Liquid-295 4110/114 Liquid Containers
Section C Page 77) 230L 5030/139

CD M Carbon Dioxide U.S.P. Grade 99.0% 180L Gas-320 400 lb /182 kg 206 SERIES: Special Purpose
(for more information see Liquid-320 Liquid Containers
Section C Page 75) 308 SERIES: Special Purpose

Gases In High Pressure


Cylinders
Y M Y M
LITHO PREP
NI M Nitrogen N.F. Grade 99.0% T 580 304/8.43 109 SERIES: General Purpose LITHO PREP

C K C K
(for more information see K 228/6.32 300 SERIES: Non-Corrosive
Page 27 of this section)

NI 5.0 M Nitrogen N.F. Grade 99.999% T 580 304/8.43 300 SERIES: Non-Corrosive
(for more information see K 228/6.32
Page 27 of this section)

CD M Carbon Dioxide U.S.P. Grade 99.0% K 320 64 lb /29.5 kg 109 SERIES: General Purpose
(for more information see 308 SERIES: Special Purpose
Page 26 of this section)

MEDICAL DEVICE GASES


Biological Incubation Atmospheres

Aerobic Incubation Mixtures

BI OXCD5C 5% Carbon Dioxide/Oxygen T 500 304/8.43 200 SERIES: Non-Corrosive


BI OXCD10C 10% Carbon Dioxide/Oxygen K 500 228/6.32 109 SERIES: General Purpose
BI NICDOXC1 5% Carbon Dioxide 5% Oxygen/Nitrogen (available for 500
BI NICDOXC2 5% Carbon Dioxide 10% Oxygen/Nitrogen all mixtures) 500
BI NICDOXC3 2.5% Carbon Dioxide 21% Oxygen/Nitrogen 500
BI NICDOXC4 5% Carbon Dioxide 21% Oxygen/Nitrogen 500
BI NICDOXC5 10% Carbon Dioxide 21% Oxygen/Nitrogen 500
BI NICDOXC6 15% Carbon Dioxide 21% Oxygen/Nitrogen 500

Anaerobic Incubation Mixtures

BI NICD5C 5% Carbon Dioxide/Nitrogen T 500 304/8.43 200 SERIES: Non-Corrosive


BI NICD10C 10% Carbon Dioxide/Nitrogen K 500 228/6.32 109 SERIES: General Purpose
BI NICDHYC1 5% Carbon Dioxide 5% Hydrogen/Nitrogen (available for350
BI NICDHYC2 5% Carbon Dioxide 10% Hydrogen/Nitrogen all mixtures)350
BI NICDHYC3 10% Carbon Dioxide 10% Hydrogen/Nitrogen 350
BA CDHY4C 4% Hydrogen 96% Carbon Dioxide T 350 95/2.63 200 SERIES: Non-Corrosive
K 350 84/2.33 109 SERIES: General Purpose
For ordering purposes, please add the desired cylinder style to the end of the above part number.
All incubation mixtures are supplied as certified standards. All incubation mixtures are certified to USP standards.
E For applications which do not require a reported analysis, non-certified grades are available.

32

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-32

600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/33-34 5/27/03 6:16 PM Page 33

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


STERILIZATION
STERILANT GASES AND MIXTURES

Praxair is a supplier of ethylene oxide- For additional information, please


based sterilant gases. These gases are request a Material Safety Data Sheet
used in the sterilization of a variety of for the sterilizing gas to be utilized.
medical devices, surgical equipment Praxair offers two major categories of
and similar materials used in the products. The choice you make
healthcare industry. depends on your equipment and your
Praxair Specialty Gases operations sterilization needs.
utilizes special cylinder cleaning and
inspection procedures to ensure the
purity of these products. These special
cleaning procedures have minimized
polymer problems.
Sterilant gases users should be
familiar with the properties of these
gases, especially the hazards of
exposure to ethylene oxide. Cylinder
labels should be read and understood
prior to use.

Y M Y M
LITHO PREP LITHO PREP

C K Ethylene Oxide/Halocarbon Mixtures Oxyfume® 2002 is a non-flammable With Oxyfume® 2002, you can sterilize all C K

Oxyfume® gases are effective and time- blend of HCFCs and ethylene oxide. Many the devices you’ve always sterilized with
tested sterilants. They have been the industry hospitals have converted to Oxyfume® 2002 ethylene oxide. Oxyfume® 2002 contains
choice for more than 35 years. The from Oxyfume® 2000 because it offers 10% ethylene oxide by weight. The product
composition of the Oxyfume® mixtures is greater efficiency which translates into cost also contains a mixture of two
contained in the following table. savings for the hospital. It works in either hydrochlorofluorocarbons (HCFCs) which act
small or large chambers, and lets you stay as carrier gases and flame suppressants.
with the same wraps, trays and procedures
you’re currently using.

Ethylene Oxide/Halocarbon Mixtures


Part Product Description Cyl. Style/ Contents Pressure
No. CGA lb/kg psig/kPa,gauge

Oxyfume® 2002
FS OXY2002-FC 10% Ethylene Oxide FC/510 135/61.2 48/324
FS OXY2002-FX 63% HCFC-124 FX/510 270/122.5 48/324
27% HCFC-22

Oxyfume® 2000
FS OXY2000-FC 8.6% Ethylene Oxide FC/510 135/61.2 26/176
91.4% HCFC-124

Remember, if you are considering a change in sterilant gas, always contact the sterilizer
manufacturer first to ensure compatibility. If you are considering alternative technologies,
contact your Praxair representative for assistance.
E
33

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-33

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
L.P...Sec.E/33-34 5/27/03 6:16 PM Page 34

Y M
LITHO PREP

C K

PRODUCTS FOR SPECIAL APPLICATIONS


STERILIZATION
STERILANT GASES AND MIXTURES

Ethylene Oxide/Carbon Dioxide flammable, carbon dioxide based sterilant Oxyfume® 20 is a flammable gas sterilant
Mixtures gas. Medifume™ is cost effective and that is generally used in industrial
Medifume™ : Although ethylene environmentally friendly. In most cases, the applications. It contains 20% ethylene oxide
oxide/carbon dioxide mixtures have been use of Medifume™ results in significant and 80% carbon dioxide.
used for many years, the Medifume™ reduction of sterilization costs. Not all
product was introduced only three years sterilizers can use Medifume™. Contact your Remember, if you are considering a change
ago. This non-flammable gas mixture was Praxair representative for additional in sterilant gas, always contact the sterilizer
developed to replace the CFC-12 which information. manufacturer first to ensure compatibility. If
was phased out of production due to you are considering alternative technologies,
ozone depleting characteristics. The Carboxide® is a flammable gas sterilant contact your Praxair representative for
concentration of ethylene oxide in that is generally used in industrial assistance.
Medifume™ is lower than Oxyfume® 20 applications. It contains 10% ethylene oxide
and Carboxide®. The result is a non- and 90% carbon dioxide.

Ethylene Oxide/Carbon Dioxide Mixtures


Part Product Description Cyl. Style/ Contents Pressure
No. CGA lb/kg psig/kPa,gauge

MedifumeTM
FS MEDI8.5-T 8.5% Ethylene Oxide T/350 75/34 750/5063
Y M
FS MEDI8.5-K 91.5% Carbon Dioxide K/350 60/27.3 750/5063 Y M
LITHO PREP LITHO PREP

C K C K
Carboxide®
FS CARB10-K 10% Ethylene Oxide K/350 60/27.3 750/5063
90% Carbon Dioxide

Oxyfume® 20
FS OXY20-T 20% Ethylene Oxide T/350 75/34 675/4556
FS OXY20-K 80% Carbon Dioxide K/350 60/27.3 675/4556

Remember, if you are considering a change in sterilant gas, always contact the sterilizer
manufacturer first to ensure compatibility. If you are considering alternative technologies,
contact your Praxair representative for assistance.

E
34

Y M
customer: VANIDES GRAPHICS/MARKETING
LITHO PREP
date: 12/07/96 A 194
C K
job: Praxair Catalog E-34

LITHO PREP 600 S. County Line Rd.• Bensenville IL, 60106


Phone: 708-860-0120 • FAX: 708-860-0272 black
GAS HANDLING EQUIPMENT
REGULATORS
The Praxair Advantage in Regulators

Praxair is committed to providing every contamination and provides gas stream Capsule® Technology features:
customer with reliable, safe and efficient filtration. This design allows the Capsule to
■ Reliable Performance
regulation equipment to meet the most be tested as a separate component prior to
demanding and precise applications. assembly into the regulator. The complete ■ Longer Life
regulators are also 100% tested, giving the ■ Wide Product Range
To meet rigorous requirements of end-users
seat or “heart” of the device a double test. ■ Minimal Need for Spare Parts Inventory
in the analytical, scientific, and electronics
The result is longer life and reliable ■ Easy Repair and Service
markets, Praxair uses a unique regulator
performance.
seat assembly that incorporates the several
individual parts of a standard regulator seat Our seat material is high grade Teflon®
into a single component. Praxair uses the (PTFE)*. Teflon continuously adjusts to form
innovative Capsule® seat assembly. All seat- a gas tight seal and retains its sealing pro-
related components are self-contained in a perties over a wider range of temperatures
sealed module. A large 10 micron sintered than most other seat materials. These pro-
metal filter is an integral part of the Capsule, perties provide a longer useful seat life even

1-877-PRAXAIR
protecting the valve components from any in the most demanding environment.

Lateral Flow Passages


Instead of impinging directly on the dia-
phragm, the gas enters the low pressure
chamber through a side outlet of the
Capsule. This smooth transition from high


pressure to low pressure reduces the effects

www.praxair.com/specialtygases
of gas surge on the diaphragm and mini-
mizes regulator hum. In addition, the lateral
flow passages induce a swirling effect which
yields a completely swept internal cavity
for complete purging.

Multiple Orifice Sizes


Each regulator has a specially designed
Capsule to optimize regulator characteris-
tics over a broad range of applications.
However, there are applications requiring
higher or lower flows than the standard
Capsule can offer. By substituting a Cap-
sule with a larger or smaller orifice, Praxair PTFE Teflon Seat 10 Micron Filter
can tailor the regulator to meet a specific
The standard seat material is high density Particles trapped between the seat and
requirement.
PTFE Teflon. Teflon is an inert material which orifice prevent proper seat closure causing
will not react with or contaminate any high the regulator to fail. The Capsule incorpo-
purity gas. In addition, Teflon retains its rates a 10 micron filter which completely
sealing properties over a wider temperature surrounds the seat components to prevent
range than most other seat materials. The the entrance of these damaging particles,
inlet pressure rating of all Praxair regulators virtually eliminating the cause of such filter
with a Teflon seat is 3000 psig (210 bar). failures. In addition, this filter is very fine, the
With the optional Kel-F® seated Capsule large surface area is resistant to clogging
the pressure rating increases to 4500 psig and allows unrestricted flow. The 10 micron
(300 bar). filter is a key factor in the long life and
reliable performance of Praxair regulators.
High Load Marginal Spring
The purpose of the marginal spring is to
close the seat independent of gas pres-
sures. The innovative Capsule design
utilizes a high force spring that assures
a gas-tight seal under all conditions.

F
1
GAS HANDLING EQUIPMENT
REGULATORS
Regulator Summary and Reference Guide

Regulator Summary
Critical Purity – 400 Series Regulators The 300 Series regulators are available for The following Regulator Reference Guide
These stainless steel and brass regulators both corrosive and non-corrosive service. will assist you in the appropriate selection of
are highly recommended where purity and a Specialty Gas regulator. We have provided
High Purity Economical –
contamination requirements are extremely a “Series” recommendation for each pure
200 Series Regulators
important. They are most often used with gas offered in this catalog. Within each
These chrome-plated forged brass regulators
Critical Purity Gases (greater than 99.9995% Series select which model best suits your
have similar features to the 300 Series with
or purity grade 5.5) and Toxic or Flammable needs using the selection and reference
a few specific design characteristics. They
gases, where vent lines are required from guidelines. If you have any questions, con-
are most often used with high purity gases
the regulator. The 400 Series regulators tact your local Praxair Specialty Gases
(less than 99.999% or purity grade 5.0)
are available for both corrosive and non- representative or Customer Service Center.
when higher flow rates are required and
corrosive service.
cost is the most important issue. The 200
High Purity – 300 Series Regulators Series regulators are available for non-
These chrome-plated brass/stainless steel corrosive service.
www.praxair.com/specialtygases

regulators are recommended for applica-


Special Purpose Regulators
tions where diffusion resistance is an im-
These regulators incorporate quality features
portant factor in ensuring purity. They are
from all of the above series. They have been
most often used with high purity gases
designed with special features for specific
(equal to 99.999% or purity grade 5.0).
applications.

Reference Guide
Critical Purity – 400 Series Special Purpose Regulators
Non-Corrosive Models Regulator Type Page Regulator Models Regulator Type Page
412 Series Dual Stage F5 206 Series Liquid Containers Single Stage F21
402 Series Single Stage F6 for Gas Withdrawl

405 Series Line Regulator F7 308 Series Carbon Dioxide and Single Stage F22
Nitrous Oxide (electrically heated)
Corrosive Models Regulator Type Page
325 Series Lecture Bottle Single Stage F23

432 Series Dual Stage F8


408 Series Mildly Corrosive Gases Single Stage F24
1-877-PRAXAIR

422 Series Single Stage F9 and Toxic Mixtures


425 Series Line Regulator F10 455 Series Highly Corrosive Single Stage F25
High Purity – 300 Series ASB Series Corrosive Single Stage F26
Non-Corrosive Models Regulator Type Page 502 Series Purges Deep, Tee and Straight F27
312 Series Dual Stage F11 TSC and SSC Series Very Low Single Stage and F28
302 Series Single Stage F12 Delivery Pressure Dual Stage

304 Series Line Regulator F13 470 and 480 Series Single Stage F29
Back Pressure Control
Corrosive Models Regulator Type Page
483 and 485 Series Single Stage F30
332 Series Dual Stage F14 High Flow Non-Corrosive
322 Series Single Stage F15 484 and 486 Series Single Stage F31
324 Series Line Regulator F16 High Flow Corrosive

High Purity Economical – 200 Series 492 and 493 Series Single Stage F32
Ultra High Pressure
Non-Corrosive Models Regulator Type Page
400, 500, 6000 and 8000 Series Single Stage F33-F34
212 Series Dual Stage F17 Portable Cylinders
202 Series Single Stage F18
205 Series Line Regulator F19

General Purpose – 109 Series


Non-Corrosive Models Regulator Type Page
109-75 Dual Stage F20
109-65 Single Stage F20

F
2
GAS HANDLING EQUIPMENT
REGULATORS
How to Select Praxair Regulators

Most specialty gases are supplied in 1. Materials Compatibility 5. Output Pressure Range
cylinders compressed to high pressures. Materials used to construct regulators Regulators must be able to reduce pressure
Pressure regulators reduce these high must be compatible with the gas – to levels compatible with the operating sys-
pressures to lower pressures that can be especially those materials (wetted parts) in tem and consistent with process needs.
safely used in an operating system. Proper contact with the gas. Praxair offers a wide Praxair’s extensive line of pressure reg-
regulator selection is critical for both safety variety of regulators with various materials ulators provides numerous choices with
and effectiveness of operating systems. of construction to help ensure that the cor- delivery pressure ranges available as low
rect regulator is available for your needs. as 0-0.5 psig, or as high as 0-6000 psig.
Many variables are involved in selecting the
A materials compatibility chart is located
proper pressure regulator. While certainly 6. Inlet Pressure Rating
on page H2.
not a comprehensive list, the following pro- Regulators must be able to safely handle
vides some of the more important consider- 2. Toxicity incoming gas pressure. Here again, a
ations. To further assist in making proper Regulators must be designed with vent wide selection is available which includes
regulator selections, refer to the section C – connectors to permit the attachment of a regulators that handle inlet pressures of
Pure Gases of the Praxair Specialty Gases & vent line or disposal system as a precaution, 6000 psig or even 10,000 psig.

1-877-PRAXAIR
Equipment reference guide for equipment in the unlikely event of a diaphragm failure.
7. Helium Leak Integrity
recommendations.
3. Gas Purity Helium leak integrity is a measure of how
Like all system components, regulators well a regulator prevents gases from leak-
should be selected to protect the purity of ing into or out of a regulator body. The
the service gas. As an example, regulators measured quantity is expressed as a flow
with stainless steel diaphragms are recom- rate such as 1 x 10-9 scc/sec He (1 billionth
mended for high purity applications because of a cc/sec). In this case, a helium leak
they are more “diffusion-resistant” than integrity rating of 1 x 10-9 would indicate


those with “rubber-type” diaphragms. For that the regulator would leak enough gas
low particulate applications, consideration to fill a cubic centimeter every 33 years.

www.praxair.com/specialtygases
should be given to selecting regulators If the rating were 1 x 10-3 the regulator
with machine welded VCR® connections. would leak enough gas to fill a cubic cen-
Optional helium leak tests also help to timeter in just 17 minutes.
ensure the integrity of regulators.
Helium is used as the test gas because it is
4a. Line or Cylinder Regulator chemically inert, it’s easy to detect and it’s
Cylinder regulators as their name implies an extremely small molecule which allows
are connected directly to gas cylinders. it to pass through the smallest leak. The
Typically offered in both single and two- lower the helium leak specification, the
stage designs, cylinder regulators normally better the regulator will be at preventing
have inlet and delivery pressure gauges. leaks into the atmosphere and minimizing
contamination from gases outside the
Line regulators, on the other hand, are
regulator body.
used directly in piping systems such as
downstream of the manifold or bulk storage 8. Other Considerations
vessel. Because inlet pressure in piping sys- Other criteria for consideration include
tems is normally constant, line regulators operating temperature, flow requirements,
are typically single-stage configurations regulatory issues (e.g. medical regulators
with delivery pressure gauges only. manufactured to FDA standards), special
applications, design preferences and cost.
4b. Single or Dual Stage Design
Please call your local Praxair representative
Single stage regulators reduce pressure in
for further assistance.
one step as gas is consumed. Dual stage
regulators are actually two regulators hous- Note: Regulators are designed to control
ed in one body. The first regulator (first pressure. Generally they are supplied with
stage) is non-adjustable and reduces in- gauges that indicate pressure. Regulators
coming pressure to an intermediate setting do not measure or control flow unless
(typically 250 to 300 psig). The second equipped with devices (such as metering
stage is adjustable and reduces intermedi- valve or flowmeter) specifically designed for
ate pressure to final desired delivery pres- those purposes. See local Praxair’s new
sure. Because the second stage sees only line of flow monitoring and flow controlling
relatively minor inlet pressure changes from devices.
the first stage, dual stage regulators main-
tain steady delivery pressure and do not
require periodic adjustment. They are well
suited for applications where constant
delivery pressure is essential. F
3
GAS HANDLING EQUIPMENT
REGULATORS
How to Order Praxair Regulators

In accordance with our philosophy of flexible To complete the Part Number matrix,consult the Regulator Summary and Reference Guide
design, Praxair has developed a versatile on page F2. On this page, you will find a description of each series of Praxair regulators with
modular manufacturing system to accom- their recommended application and appropriate gas usage. You may also refer to the Pure
modate any individual requirement. With Gases section of the Praxair Specialty Gases & Equipment reference guide for equipment
all the options Praxair offers, listing discrete recommendations that will help you make the proper selection (See Section C). If you are
part numbers for each regulator series new to selecting regulators or would like a quick refresher, review the adjacent page, steps 1
would be impossible. Therefore, we have through 4. Finally, a “quick-find” reference guide on page 3 will help you identify the catalog
created a part number matrix which allows page that contains the regulator information you need. If you need additional assistance,
you to design a regulator to meet the needs please consult your local Praxair sales representative or call Praxair customer service.
of any application.
Select the desired outlet pressure range from those available in the A column.
Example
A The selection of an outlet pressure range automatically specifies the outlet pressure
gauge which appears in the adjacent column. For example, a regulator with a
When using the table below to order a
400 Series 316L stainless steel, single
0-250 psig outlet pressure range will have a 0-400 psig pressure gauge installed.
www.praxair.com/specialtygases

stage cylinder regulator with an outlet


Choose the inlet pressure gauge from those available in the B column. While the
pressure range of 0-50 psig, a 0-4000 psig B most common cylinder pressure is between 2200 psig and 2400 psig, several
inlet pressure gauge, a diaphragm valve
gases are stored in cylinders at other pressures. Choosing the inlet gauge with
with a 1/4" tube fitting, psi/kPa pressure
a range that most closely approximates the actual pressure range of the cylinder
gauges, and a CGA 580 connection for
nitrogen service, the part number would
allows easy readability of cylinder contents. Please note that by indicating the
0-6000 psig inlet gauge, you are also selecting a special Kel-F® Capsule® with
be CON4222331-580.
a maximum inlet pressure of 5500 psig.

Indicate the outlet assembly desired from those available in the C column. Since
C there are a wide variety of tubing and piping systems in use, the matrix accom-
modates virtually any style of connection, eliminating the need for adapters and
reducing potential leak paths. Praxair also offers a choice of valve options for
gas flow control.

Select an assembly option from those available in the D column. A bare body
D regulator is shipped without peripherals, with all ports open and unplugged.

A standard regulator comes completely assembled with all selected peripherals,


1-877-PRAXAIR

ready for use; a cleanroom regulator is completely assembled in a Class 10


cleanroom. Finally, each regulator must pass a battery of rigorous operational
tests and a helium leak integrity check.

Specify an inlet connection. On all regulator series, Praxair will provide any CGA,
CGA DIN 477, BS 341, or other standard connection provided it is recognized as
Highlighted selection indicates safe for the materials of construction and pressure rating of the regulator. Consult
most popular model Praxair for proper selection of the inlet connection. A “000” at the end of the
part number indicates inlet connection (1/4" female NPT).

Regulators CON422ABCD-CGA

A B C D CGA

Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig* 30"-0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body CGA, DIN 477,
2: 0-50 psig 30"-0-100 psig 3: 0-4000 psig 1: 1/4" MPT 1: Standard Assembly BS 341 and others
3: 0-100 psig 30"-0-200 psig 5: 0-1000 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) available.
4: 0-250 psig 0-400 psig 6: 0-300 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly
5: 0-500 psig 0-1000 psig 7: 0-400 psig 4: Diaphragm Valve 1/4" MPT (bar/psi Gauges)
7: 0-150 psig 30"-0-200 psig 8: 0-6000 psig 5: Needle Valve 1/4" MPT 4: Cleanroom Assembly
6: 1/8" Tube Fitting (psi/kPA Gauges)
7: 3/8" Tube Fitting 5: Cleanroom Assembly
8: Diaphragm Valve 1/8" Tube Fitting (bar/psi Gauges)
F 9: Diaphragm Valve 1/4" FPT
4 * Not available with 5500 psig inlet pressure
GAS HANDLING EQUIPMENT
412 REGULATORS
Critical Purity Regulators for Non-Corrosive Service

Dual Stage Brass Barstock Body, Six-Port


Configuration, 316L Stainless Steel Diaphragm
The 412 Series regulators are intended for primary pressure
control of non-corrosive, critical purity or liquefied gases for
applications requiring constant delivery pressure control,
regardless of supply pressure.

Typical Applications
■ EPA Protocol gases ■ Zero, span, and
■ Gas and liquid calibration gases
chromatography ■ High purity chamber
■ Ultra high purity carrier gases pressurization

1-877-PRAXAIR
Features and Benefits
■ Brass Barstock Body ■ Pressure Ranges 0-15 to ■ 316L Stainless Steel Diaphragm ■ Field-Adjustable Pressure Limit
Controlled surface integrity 0-250 psig No inboard diffusion Safeguard downstream
■ Front Panel Mountable Broad range of applications ■ Orientable Captured equipment
Easy installation ■ Metal-to-Metal Diaphragm Seal Vent Capable ■ Pipe Away Relief Valve
■ 10 Micron Filtration No possibility of Safe and easy installation Safely vent exhausted
in Both Stages gas contamination ■ Low Wetted Volume gases


Failsafe seat performance ■ Capsule® Seat Minimal purge requirements ■ Delivery Pressure Range
Increased serviceability Easily Changed

www.praxair.com/specialtygases
and life Maximum flexibility

Specifications Materials
■ Maximum Inlet Pressure ■ Ports ■ Body ■ Filter
3000 psig (210 bar) 1/4" FPT Brass barstock 10 micron multilayer,
4500 psig (300 bar) optional ■ Helium Leak Integrity ■ Bonnet sintered 316L stainless steel
■ Temperature Range 1 x 10-9 scc/sec Brass barstock wire mesh (patented)
-40 oF to 140 oF ■ Cv ■ Seat ■ Diaphragm
(-40 oC to 60 oC) 0.1 PTFE Teflon® 316L stainless steel
■ Gauges ■ Weight PCTFE with 4500 psig ■ Internal Seals
2" diameter brass 5.4 lb (2.5 kg) inlet option PTFE Teflon®

Ordering Information — Series CON412ABCD-CGA Highlighted selection indicates most popular model
A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 30"-0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body CGA,
2: 0-50 psig 30"-0-100 psig 3: 0-4000 psig 1: 1/4" MPT 1: Standard Assembly DIN 477,
3: 0-100 psig 30"-0-200 psig 5: 0-1000 psig 2: 1/4” Tube Fitting (psi/kPa Gauges) BS 341
4: 0-250 psig 0-400 psig 6: 0-300 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly and others
7: 0-150 psig 30"-0-200 psig 8: 0-6000 psig* 4: Diaphragm Valve 1/4" MPT (bar/psi Gauges) available
5: Needle Valve 1/4" MPT 4: Cleanroom Assembly
6: 1/8" Tube Fitting (psi/kPa Gauges)
7: 3/8" Tube Fitting 5: Cleanroom Assembly
* Maximum inlet pressure 4500 psig (300 bar) 8: Diaphragm Valve 1/8" Tube Fitting (bar/psi Gauges)
with PCTFE Seat Capsule 9: Diaphragm Valve 1/4" FPT

Option Part Number Description


Panel Mount Kit CON5500002 To mount the regulator using threads on the bonnet. Material: Nickel-plated brass
Captured Vent Kit CON5500001 Orientable 360o for easy piping of vented gases to a safe location in the event
of diaphragm failure. Material: Nickel-plated Brass
Helium Leak Certification CON4760002 Inboard Helium leak certification to less than 1 x 10-8 scc/sec
Protocol Station Add Letter “M” after CGA See page F35 for details
Protocol Switchover Station Add Letter “C” after CGA See page F36 for details
Protocol Switchover Station with Alarm Add Letter “G” after CGA See page F36 for details F
Protocol Alarm Station Add Letter “A” after CGA See page F37 for details
Deep Purge Add Letter “D” after CGA See page F27 for details
5
GAS HANDLING EQUIPMENT
402 REGULATORS
Critical Purity Regulators for Non-Corrosive Service

Single Stage Brass Barstock Body, Six-Port


Configuration, 316L Stainless Steel Diaphragm
The 402 Series regulators are intended for primary pressure control
of non-corrosive, critical purity or liquefied gases. It is recommended
for applications where minor fluctuations in outlet pressure due to
diminishing inlet supply can be tolerated.

Typical Applications
■ Gas and liquid ■ High purity chamber
chromatography pressurization
■ Ultra high purity carrier gases ■ Liquefied hydrocarbon
■ Zero, span, and gas control
calibration gases ■ Control of cryogenic gases
www.praxair.com/specialtygases

Features and Benefits


■ Brass Barstock Body ■ Pressure Ranges 0-15 ■ 316L Stainless Steel Diaphragm ■ Field-Adjustable Pressure Limit
Controlled surface integrity to 0-500 psig No inboard diffusion Safeguard downstream
■ Front and Rear Panel Broad range of applications ■ Orientable Captured equipment
Mountable ■ Metal-to-Metal Diaphragm Seal Vent Capable ■ Pipe Away Relief Valve
Versatile system No possibility of Safe and easy installation Safely vent
configuration gas contamination ■ Low Wetted Volume exhausted gases
■ Capsule® Seat Minimal purge requirements ■ Delivery Pressure Range
Increased serviceability Easily Changed
and life Maximum flexibility

Specifications Materials
■ Maximum Inlet Pressure ■ Ports ■ Body ■ Filter
3000 psig (210 bar) 1/4" FPT Brass barstock 10 micron multilayer,

4500 psig (300 bar) optional ■ Helium Leak Integrity ■ Bonnet sintered 316L stainless steel
wire mesh (patented)
1-877-PRAXAIR

■ Temperature Range 1 x 10-9 scc/sec Brass barstock


-40 oF to 140 oF ■ Cv ■ Seat ■ Diaphragm
(-40 oC to 60 oC) 0.1 PTFE Teflon® 316L stainless steel
■ Gauges ■ Weight PCTFE with 4500 psig ■ Internal Seals
2" diameter brass 3.8 lb (1.7 kg) inlet option PTFE Teflon®

Ordering Information — Series CON402ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig* 30"-0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body CGA,
2: 0-50 psig 30"-0-100 psig 3: 0-4000 psig 1: 1/4" MPT 1: Standard Assembly DIN 477,
3: 0-100 psig 30"-0-200 psig 5: 0-1000 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) BS 341
4: 0-250 psig 0-400 psig 6: 0-300 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly and others
5: 0-500 psig 0-1000 psig 7: 0-400 psig 4: Diaphragm Valve 1/4" MPT (bar/psi Gauges) available
7: 0-150 psig 30"-0-200 psig 8: 0-6000 psig** 5: Needle Valve 1/4" MPT 4: Cleanroom Assembly
6: 1/8" Tube Fitting (psi/kPa Gauges)
* Not available with 4500 psig inlet pressure. 7: 3/8" Tube Fitting 5: Cleanroom Assembly
** Maximum inlet pressure 4500 psig (300 bar) 8: Diaphragm Valve 1/8" Tube Fitting (bar/psi Gauges)
with PCTFE Seat Capsule. 9: Diaphragm Valve 1/4" FPT

Option Part Number Description


Panel Mount Kit CON5500002 To mount the regulator using threads on the bonnet. Material: Nickel-plated brass
Captured Vent Kit CON5500001 Orientable 360° for easy piping of vented gases to a safe location in the event
of diaphragm failure. Nickel-plated Brass
Helium Leak Certification CON4760002 Inboard helium leak certification to less than 1 x 10-8 scc/sec
Protocol Station Add Letter “M” after CGA See page F35 for details
F Protocol Switchover Station Add Letter “C” after CGA See page F36 for details
6 Protocol Switchover Station with Alarm Add Letter “G” after CGA See page F36 for details
Protocol Alarm Station Add Letter “A” after CGA See page F37 for details
Deep Purge Add Letter “D” after CGA See page F27 for details
GAS HANDLING EQUIPMENT
405 REGULATORS
Critical Purity Regulators for Non-Corrosive Service

Line Regulator, Single Stage Brass Barstock Body,


Four-Port Configuration, 316L Stainless Steel Diaphragm
The 405 Series regulators are intended for secondary pressure control
of non-corrosive, critical purity or liquefied gases. It is recommended
as point of use pressure control in critical purity gas delivery systems.

Typical Applications
■ Bulk gas delivery systems ■ High purity chamber
■ Gas and liquid pressurization
chromatography ■ Liquefied hydrocarbon
■ Ultra high purity carrier gases gas control
■ Zero, span, and ■ Control of cryogenic gases

1-877-PRAXAIR
calibration gases

Features and Benefits


■ Brass Barstock Body ■ Pressure Ranges 0-15 ■ 316L Stainless Steel Diaphragm ■ Field-Adjustable Pressure Limit
Controlled surface integrity to 0-500 psig No inboard diffusion Safeguard downstream
■ Front and Rear Panel Broad range of applications ■ Orientable Captured equipment
Mountable ■ Metal-to-Metal Diaphragm Seal Vent Capable ■ Pipe Away Relief Valve


Versatile system No possibility of Safe and easy installation Safely vent
configuration gas contamination ■ Low Wetted Volume exhausted gases

www.praxair.com/specialtygases
■ Capsule® Seat Minimal purge requirements ■ Delivery Pressure Range
Increased serviceability Easily Changed
and life Maximum flexibility

Specifications Materials
■ Maximum Inlet Pressure ■ Helium Leak Integrity ■ Body ■ Filter
3000 psig (210 bar) 1 x 10-9 scc/sec Brass barstock 10 micron multilayer,
■ Temperature Range ■ Cv ■ Bonnet sintered 316L stainless steel
-40 oF to 140 oF 0.1 (maximum outlet Brass barstock wire mesh (patented)
(-40 oC to 60 oC) 50 psig or below) ■ Seat ■ Diaphragm
■ Gauges 0.2 (maximum outlet PTFE Teflon® 316L stainless steel
2" diameter brass above 50 psig) ■ Internal Seals
■ Ports ■ Weight PTFE Teflon®
1/4" FPT 2.25 lb (1.0 kg)

Ordering Information – Series CON405ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 30"-0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body 000: 1/4" FPT
2: 0-50 psig 30"-0-100 psig 1: 1/4" MPT 1: Standard Assembly TF2: 1/8" Tube
3: 0-100 psig 30"-0-200 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) TF4: 1/4" Tube
4: 0-250 psig 0-400 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly TF6: 3/8" Tube
5: 0-500 psig 0-1000 psig 4: Diaphragm Valve 1/4" MPT (bar/psi Gauges)
7: 0-150 psig 30"-0-200 psig 5: Needle Valve 1/4" MPT 4: Cleanroom Assembly
6: 1/8" Tube Fitting (psi/kPa Gauges)
7: 3/8" Tube Fitting 5: Cleanroom Assembly
8: Diaphragm Valve 1/8" Tube Fitting (bar/psi Gauges)
9: Diaphragm Valve 1/4" FPT

Option Part Number Description


Panel Mount Kit CON5500002 To mount the regulator using threads on the bonnet. Material: Nickel-plated brass
Captured Vent Kit CON5500001 Orientable 360o for easy piping of vented gases to a safe location in the event
of diaphragm failure. Material: Nickel-plated Brass
Helium Leak Certification CON4760002 Inboard helium leak certification to less than 1 x 10-8 scc/sec F
Reversed Inlet/Outlet Configuration Contact Praxair Inlet and outlet ports supplied in a reversed ("mirror image") configuration 7
GAS HANDLING EQUIPMENT
432 REGULATORS
Critical Purity Regulators for Corrosive Service

Dual Stage 316L Stainless Steel Barstock Body,


Six-Port Configuration, 316L Stainless Steel Diaphragm
The 432 Series regulators are intended for primary pressure
control of critical purity and corrosive gases. It is recommended
for applications requiring constant delivery pressure control,
regardless of supply pressure.

Typical Applications
■ EPA Protocol gases ■ Zero, span, and
■ Gas and liquid calibration gases
chromatography ■ High purity chamber
■ Ultra high purity carrier gases pressurization
www.praxair.com/specialtygases

Features and Benefits


■ 316L Stainless Steel ■ Pressure Ranges 0-15 ■ 316L Stainless Steel Diaphragm ■ Field-Adjustable Pressure Limit
Barstock Body to 0-250 psig No inboard diffusion Safeguard downstream
Enhanced corrosion Broad range of applications ■ Orientable Captured equipment
resistance ■ Metal-to-Metal Diaphragm Seal Vent Capable ■ Pipe Away Relief Valve
■ Front Panel Mountable No possibility of Safe and easy installation Safely vent
Easy installation gas contamination ■ Low Wetted Volume exhausted gases
■ 10 Micron Filtration ■ Capsule® Seat Minimal purge requirements ■ Delivery Pressure Range Easily
in Both Stages Increased serviceability Changed
Failsafe seat performance and life Maximum flexibility

Specifications Materials
■ Maximum Inlet Pressure ■ Ports ■ Body ■ Filter
3000 psig (210 bar) 1/4" FPT 316L stainless steel barstock 10 micron multilayer,
4500 psig (300 bar) optional ■ Helium Leak Integrity ■ Bonnet sintered 316L stainless steel

■ Temperature Range 1 x 10-9 scc/sec Chrome-plated brass barstock wire mesh (patented)
1-877-PRAXAIR

-40 oF to 140 oF ■ Cv ■ Seat ■ Diaphragm


(-40 oC to 60 oC) 0.1 PTFE Teflon®, PCTFE with 316L stainless steel
■ Gauges ■ Weight 4500 psig inlet option ■ Internal Seals
2" diameter stainless steel 5.4 lb (2.5 kg) PTFE Teflon®

Ordering Information – Series CON432ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 30"-0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body CGA,
2: 0-50 psig 30"-0-100 psig 3: 0-4000 psig 1: 1/4" MPT 1: Standard Assembly DIN 477,
3: 0-100 psig 30"-0-200 psig 5: 0-1000 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) BS 341
4: 0-250 psig 0-400 psig 6: 0-300 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly and others
7: 0-150 psig 30"-0-200 psig 7: 0-400 psig 4: Diaphragm Valve 1/4" MPT (bar/psi Gauges) available
8: 0-6000 psig* 5: Needle Valve 1/4" MPT 4: Cleanroom Assembly
6: 1/8" Tube Fitting (psi/kPa Gauges)
7: 3/8" Tube Fitting 5: Cleanroom Assembly
* Maximum inlet pressure 4500 psig (300 bar) 8: Diaphragm Valve 1/8" Tube Fitting (bar/psi Gauges)
with PCTFE Seat Capsule. 9: Diaphragm Valve 1/4" FPT

Option Part Number Description


Panel Mount Kit CON5500002 To mount the regulator using threads on the bonnet. Material: Nickel-plated brass
Captured Vent Kit CON5500001 Orientable 360o for easy piping of vented gases to a safe location in the event
of diaphragm failure. Material: Nickel-plated Brass
Helium Leak Certification CON4760002 Inboard helium leak certification to less than 1 x 10-8 scc/sec
Protocol Station Add Letter “M” after CGA See page F35 for details
Protocol Switchover Station Add Letter “C” after CGA See page F36 for details
F Protocol Switchover Station with Alarm Add Letter “G” after CGA See page F36 for details
Protocol Alarm Station Add Letter “A” after CGA See page F37 for details
8 Deep Purge Add Letter “D” after CGA See page F27 for details
GAS HANDLING EQUIPMENT
422 REGULATORS
Critical Purity Regulators for Corrosive Service

Single Stage 316L Stainless Steel Barstock Body,


Six-Port Configuration, 316L Stainless Steel Diaphragm
The 422 Series regulators are intended for primary pressure
control of critical purity and corrosive gases. It is recommended
for applications where minor fluctuations in outlet pressure due
to diminishing inlet supply can be tolerated.

Typical Applications
■ Gas and liquid ■ High purity chamber
chromatography pressurization
■ Ultra high purity carrier gases ■ Liquefied hydrocarbon
■ Zero, span, and gas control
calibration gases ■ Control of cryogenic gases

1-877-PRAXAIR
Features and Benefits

■ 316L Stainless Steel ■ Pressure Ranges 0-15 ■ 316L Stainless Steel Diaphragm ■ Field-Adjustable Pressure Limit
Barstock Body to 0-500 psig No inboard diffusion Safeguard downstream
Enhanced corrosion Broad range of applications ■ Orientable Captured equipment
resistance ■ Metal-to-Metal Diaphragm Seal Vent Capable ■ Pipe Away Relief Valve
■ Front and Rear No possibility of Safe and easy installation Safely vent exhausted gases


Panel Mountable gas contamination ■ Low Wetted Volume ■ Delivery Pressure Range
Versatile system ■ Capsule® Seat Minimal purge requirements Easily Changed

www.praxair.com/specialtygases
configuration Increased serviceability Maximum flexibility
and life

Specifications Materials
■ Maximum Inlet Pressure ■ Ports ■ Body ■ Filter
3000 psig (210 bar) 1/4" FPT 316L stainless steel barstock 10 micron multilayer,
4500 psig (300 bar) optional ■ Helium Leak Integrity ■ Bonnet sintered 316L stainless steel
■ Temperature Range 1 x 10-9 scc/sec Chrome-plated brass barstock wire mesh (patented)
-40 oF to 140 oF ■ Cv ■ Seat ■ Diaphragm
(-40 oC to 60 oC) 0.1 PTFE Teflon® 316L stainless steel
■ Gauges ■ Weight PCTFE with 4500 psig ■ Internal Seals
2" diameter stainless steel 3.8 lb (1.7 kg) inlet option PTFE Teflon®

Ordering Information – Series CON422ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly Gauges Inlet Connections
1: 0-15 psig* 30"-0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body CGA,
2: 0-50 psig 30"-0-100 psig 3: 0-4000 psig 1: 1/4" MPT 1: Standard Assembly DIN 477,
3: 0-100 psig 30"-0-200 psig 5: 0-1000 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) BS 341
4: 0-250 psig 0-400 psig 6: 0-300 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly and others
5: 0-500 psig 0-1000 psig 7: 0-400 psig 4: Diaphragm Valve 1/4" MPT (bar/psi Gauges) available
7: 0-150 psig 30"-0-200 psig 8: 0-6000 psig** 5: Needle Valve 1/4" MPT 4: Cleanroom Assembly
6: 1/8" Tube Fitting (psi/kPa Gauges)
* Not available with 4500 psig inlet pressure 7: 3/8" Tube Fitting 5: Cleanroom Assembly
** Maximum inlet pressure 4500 psig (300 bar) 8: Diaphragm Valve 1/8" Tube Fitting (bar/psi Gauges)
with PCTFE Seat Capsule. 9: Diaphragm Valve 1/4" FPT

Option Part Number Description


Panel Mount Kit CON5500002 To mount the regulator using threads on the bonnet. Material: Nickel-plated brass
Captured Vent Kit CON5500001 Orientable 360o for easy piping of vented gases to a safe location in the event
of diaphragm failure. Material: Nickel-plated Brass
Helium Leak Certification CON4760002 Inboard Helium leak certification to less than 1 x 10-8 scc/sec
Protocol Station Add Letter “M” after CGA See page F35 for details
Protocol Switchover Station Add Letter “C” after CGA See page F36 for details F
Protocol Switchover Station with Alarm Add Letter “G” after CGA See page F36 for details 9
Protocol Alarm Station Add Letter “A” after CGA See page F37 for details
Deep Purge Add Letter “D” after CGA See page F27 for details
GAS HANDLING EQUIPMENT
425 REGULATORS
Critical Purity Regulator for Corrosive Service

Line Regulator, Single Stage 316L Stainless Steel


Barstock Body, 316L Stainless Steel Diaphragm
The 425 Series regulators are intended for secondary pressure control
of critical purity and corrosive gases. It is recommended as point of
use pressure control in critical purity gas delivery systems.

Typical Applications
■ Bulk gas delivery systems ■ High purity chamber
■ Gas and liquid pressurization
chromatography ■ Liquefied hydrocarbon
■ Ultra high purity carrier gases gas control
■ Zero, span, and ■ Control for cryogenic gases
www.praxair.com/specialtygases

calibration gases

Features and Benefits


■ 316L Stainless Steel ■ 3000 psig Inlet Pressure Rating ■ 316L Stainless Steel Diaphragm ■ Field-Adjustable Pressure Limit
Barstock Body Safe use with high No inboard diffusion Safeguard downstream
Enhanced corrosion resistance pressure cylinders ■ Orientable Captured equipment
■ Front and Rear ■ Metal-to-Metal Diaphragm Seal Vent Capable ■ Pipe Away Relief Valve
Panel Mountable No possibility of Safe and easy installation Safely vent exhausted gases
Versatile system configuration gas contamination ■ Low Wetted Volume ■ Delivery Pressure Range Easily
■ Pressure Ranges 0-15 ■ Capsule® Seat Minimal purge requirements Changed
to 0-500 psig Increased serviceability Maximum flexibility
Broad range of applications and life

Specifications Materials

■ Maximum Inlet Pressure ■ Helium Leak Integrity ■ Body ■ Filter


3000 psig (210 bar) 1 x 10-9 scc/sec 316L stainless stee barstock 10 micron multilayer,
1-877-PRAXAIR

■ Temperature Range ■ Cv ■ Bonnet sintered 316L stainless steel


-40 oF to 140 oF 0.1 (maximum outlet 50 psig Chrome-plated brass wire mesh (patented)
(-40 oC to 60 oC) or below) barstock ■ Diaphragm
■ Gauges 0.2 (maximum outlet above ■ Seat 316L stainless steel
2" diameter stainless steel 50 psig) PTFE Teflon® ■ Internal Seals
■ Ports ■ Weight PTFE Teflon®
1/4" FPT 2.25 lb (1.0 kg)

Ordering Information – Series CON425ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 30"-0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body 000: 1/4" FPT
2: 0-50 psig 30"-0-100 psig 1: 1/4" MPT 1: Standard Assembly TF2: 1/8" Tube
3: 0-100 psig 30"-0-200 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) TF4: 1/4" Tube
4: 0-250 psig 0-400 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly TF6: 3/8" Tube
5: 0-500 psig 0-1000 psig 4: Diaphragm Valve 1/4" MPT (bar/psi Gauges)
7: 0-150 psig 30"-0-200 psig 5: Needle Valve 1/4" MPT 4: Cleanroom Assembly
6: 1/8" Tube Fitting (psi/kPa Gauges)
7: 3/8" Tube Fitting 5: Cleanroom Assembly
8: Diaphragm Valve 1/8" Tube Fitting (bar/psi Gauges)
9: Diaphragm Valve 1/4" FPT

Option Part Number Description


Panel Mount Kit CON5500002 To mount the regulator using threads on the bonnet. Material: Nickel-plated brass
Captured Vent Kit CON5500001 Orientable 360o for easy piping of vented gases to a safe location in the event
of diaphragm failure. Material: Nickel-plated Brass
F
Helium Leak Certification CON4760002 Inboard helium leak certification to less than 1 x 10-8 scc/sec
10 Reversed Inlet/Outlet Configuration Contact Praxair Inlet and outlet ports supplied in a reversed ("mirror image") configuration
GAS HANDLING EQUIPMENT
312 REGULATORS
High Purity Regulators for Non-Corrosive Service

Dual Stage Chrome-Plated Brass Barstock Body,


Four-Port Configuration, 316L Stainless Steel
Diaphragm
The 312 Series regulators are intended for primary pressure
control of non-corrosive, high purity or liquefied gases. It is
recommended for applications requiring constant delivery
pressure control, regardless of supply pressure.

Typical Applications
■ EPA Protocol gases ■ Zero, span, and
■ Gas and liquid calibration gases
chromatography ■ High purity chamber
■ High purity carrier gases pressurization

1-877-PRAXAIR
Features and Benefits
■ Chrome-Plated Brass ■ Pressure Ranges 0-15 ■ 316L Stainless Steel Diaphragm ■ Convoluted Diaphragm
Barstock Body to 0-250 psig No inboard diffusion Smooth pressure transition
Controlled surface integrity Broad range of applications ■ Low Wetted Volume ■ Compact Ergonomic Design
■ 10 Micron Filtration ■ Capsule® Seat Minimal purge requirements Easily transported
in Both Stages Increased serviceability ■ Field-Adjustable Pressure Limit and integrated


Failsafe seat performance and life Safeguard downstream
equipment

www.praxair.com/specialtygases
Specifications Materials
■ Maximum Inlet Pressure ■ Ports ■ Body ■ Filter
3000 psig (210 bar) 1/4" FPT Chrome-plated brass 10 micron multilayer, sintered
■ Temperature Range ■ Helium Leak Integrity barstock 316L stainless steel wire mesh
-40 oF to 140 oF 1 x 10-8 scc/sec ■ Bonnet (patented)
(-40 oC to 60 oC) ■ Cv Chrome-plated die cast zinc ■ Diaphragm
■ Gauges 0.1 ■ Seat 316L stainless steel
2" diameter ■ Weight PTFE Teflon® ■ Internal Seals
chrome-plated brass 4.8 lb (2.2 kg) PTFE Teflon®

Ordering Information – Series CON312ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 30"-0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body CGA,
2: 0-50 psig 30"-0-100 psig 3: 0-4000 psig 1: 1/4" MPT 1: Standard Assembly DIN 477,
3: 0-100 psig 30"-0-200 psig 5: 0-1000 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) BS 341
4: 0-250 psig 0-400 psig 6: 0-300 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly and others
7: 0-150 psig 30"-0-200 psig 7: 0-400 psig 4: Diaphragm Valve 1/4" MPT (bar/psi Gauges) available
5: Needle Valve 1/4" MPT
6: 1/8" Tube Fitting
7: 3/8" Tube Fitting
8: Diaphragm Valve 1/8" Tube Fitting
9: Diaphragm Valve 1/4" FPT

Option Part Number Description


Helium Leak Certification CON4760002 Inboard helium leak certification to less than 1 x 10-8 scc/sec
Protocol Station Add Letter “M” after CGA See page F35 for details
Protocol Switchover Station Add Letter “C” after CGA See page F36 for details
Protocol Switchover Station with Alarm Add Letter “G” after CGA See page F36 for details
Protocol Alarm Station Add Letter “A” after CGA See page F37 for details
Deep Purge Add Letter “D” after CGA See page F27 for details

F
11
GAS HANDLING EQUIPMENT
302 REGULATORS
High Purity Regulators for Non-Corrosive Service

Single Stage Chrome-Plated Brass Barstock Body,


Four-Port Configuration, 316L Stainless Steel
Diaphragm
The 302 Series regulators are intended for primary pressure control
of non-corrosive, high purity or liquefied gases. It is recommended
for applications where minor fluctuations in outlet pressure due to
diminishing inlet supply can be tolerated.

Typical Applications
■ Gas and liquid ■ High purity chamber
chromatography pressurization
■ High purity carrier gases ■ Liquefied hydrocarbon
■ Zero, span, and gas control
www.praxair.com/specialtygases

calibration gases ■ Control for cryogenic gases

Features and Benefits


■ Chrome-Plated ■ Pressure Ranges 0-15 ■ 316L Stainless Steel Diaphragm ■ Convoluted Diaphragm
Brass Barstock Body to 0-500 psig No inboard diffusion Smooth pressure transition
Controlled surface integrity Broad range of applications ■ Low Wetted Volume ■ Compact Ergonomic Design
■ Rear Panel Mountable ■ Capsule® Seat Minimal purge requirements Easily transported
Easy installation Increased serviceability ■ Field-Adjustable Pressure Limit and integrated
and life Safeguard downstream
equipment

Specifications Materials
■ Maximum Inlet Pressure ■ Ports ■ Body ■ Filter
3000 psig (210 bar) 1/4" FPT Chrome-plated brass 10 micron multilayer,

■ Temperature Range ■ Helium Leak Integrity barstock sintered 316L stainless steel
-40 oF to 140 oF 1 x 10-8 scc/sec ■ Bonnet wire mesh (patented)
1-877-PRAXAIR

(-40 oC to 60 oC) ■ Cv Chrome-plated die cast zinc ■ Diaphragm


■ Gauges 0.1 ■ Seat 316L stainless steel
2" Diameter ■ Weight PTFE Teflon® ■ Internal Seals
chrome-plated brass 3.2 lb (1.5 kg) PTFE Teflon®

Ordering Information – Series CON302ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 30"-0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body CGA,
2: 0-50 psig 30"-0-100 psig 3: 0-4000 psig 1: 1/4" MPT 1: Standard Assembly DIN 477,
3: 0-100 psig 30"-0-200 psig 5: 0-1000 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) BS 341
4: 0-250 psig 0-400 psig 6: 0-300 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly and others
5: 0-500 psig 0-1000 psig 7: 0-400 psig 4: Diaphragm Valve 1/4" MPT (bar/psi Gauges) available
7: 0-150 psig 30"-0-200 psig 5: Needle Valve 1/4" MPT
6: 1/8" Tube Fitting
7: 3/8" Tube Fitting
8: Diaphragm Valve 1/8" Tube Fitting
9: Diaphragm Valve 1/4" FPT

Option Part Number Description


Helium Leak Certification CON4760002 Inboard helium leak certification to less than 1 x 10-8 scc/sec
Protocol Station Add Letter “M” after CGA See page F35 for details
Protocol Switchover Station Add Letter “C” after CGA See page F36 for details
Protocol Switchover Station with Alarm Add Letter “G” after CGA See page F36 for details
Protocol Alarm Station Add Letter “A” after CGA See page F37 for details
Deep Purge Add Letter “D” after CGA See page F27 for details
F
12
GAS HANDLING EQUIPMENT
304 REGULATORS
High Purity Regulators for Non-Corrosive Service

Line Regulator, Single Stage Chrome-Plated


Brass Barstock Body, Three-Port Configuration,
316L Stainless Steel Diaphragm
The 304 Series regulators are intended for secondary pressure
control of non-corrosive, high purity or liquefied gases. It is also
recommended as point of use pressure control in high purity gas
delivery systems.

Typical Applications
■ Bulk gas delivery systems ■ High purity chamber
■ Gas and liquid pressurization
chromatography ■ Liquefied hydrocarbon
■ High purity carrier gases gas control

1-877-PRAXAIR
■ Zero, span, and ■ Control for cryogenic gases
calibration gases

Features and Benefits


■ Chrome-Plated Brass ■ 3000 psig Inlet Pressure Rating ■ 316L Stainless Steel Diaphragm ■ Convoluted Diaphragm
Barstock Body Safe use with high No inboard diffusion Smooth pressure transition
Controlled surface integrity pressure cylinders ■ Low Wetted Volume ■ Compact Ergonomic Design


■ Rear Panel Mountable ■ Capsule® Seat Minimal purge requirements Easily transported
Easy installation Increased serviceability and integrated

www.praxair.com/specialtygases
■ Field-Adjustable Pressure Limit
■ Pressure Ranges 0-15 and life Safeguard downstream
to 0-500 psig equipment
Broad range of applications

Specifications Materials
■ Maximum Inlet Pressure ■ Helium Leak Integrity ■ Body ■ Filter
3000 psig (210 bar) 1 x 10-8 scc/sec Chrome-plated brass 10 micron multilayer,
■ Temperature Range ■ Cv barstock sintered 316L stainless steel
-40 oF to 140 oF 0.1 (maximum outlet 50 psig ■ Bonnet wire mesh (patented)
(-40 oC to 60 oC) or below) Chrome-plated die cast zinc ■ Diaphragm
■ Gauges 0.2 (maximum outlet above ■ Seat 316L stainless steel
2" diameter 50 psig) PTFE Teflon® ■ Internal Seals
chrome-plated brass ■ Weight PTFE Teflon®
■ Ports 2.8 lb (1.3 kg)
1/4" FPT

Ordering Information – Series CON304ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 30"-0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body 000: 1/4" FPT
2: 0-50 psig 30"-0-100 psig 1: 1/4" MPT 1: Standard Assembly TF2: 1/8" Tube
3: 0-100 psig 30"-0-200 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) TF4: 1/4" Tube
4: 0-250 psig 0-400 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly TF6: 3/8" Tube
5: 0-500 psig 0-1000 psig 4: Diaphragm Valve 1/4" MPT (bar/psi Gauges)
7: 0-150 psig 30"-0-200 psig 5: Needle Valve 1/4" MPT
6: 1/8" Tube Fitting
7: 3/8" Tube Fitting
8: Diaphragm Valve 1/8" Tube Fitting
9: Diaphragm Valve 1/4" FPT

Option Part Number Description


Helium Leak Certification CON4760002 Inboard helium leak certification to less than 1 x 10-8 scc/sec
F
13
GAS HANDLING EQUIPMENT
332 REGULATORS
High Purity Regulators for Corrosive Service

Dual Stage 316L Stainless Steel Barstock Body,


Four-Port Configuration, 316L Stainless Steel
Diaphragm
The 332 Series regulators are intended for primary pressure
control of high purity and corrosive gases. It is recommended
for applications requiring constant delivery pressure control,
regardless of supply pressure.

Typical Applications
■ EPA Protocol gases ■ Zero, span, and
■ Gas and liquid calibration gases
chromatography ■ High purity chamber
■ High purity carrier gases pressurization
www.praxair.com/specialtygases

Features and Benefits


■ 316L Stainless Steel ■ Pressure Ranges 0-15 ■ 316L Stainless Steel Diaphragm ■ Convoluted diaphragm
Barstock Body to 0-250 psig No inboard diffusion Smooth pressure transition
Enhanced corrosion Broad range of applications ■ Low Wetted Volume ■ Compact Ergonomic Design
resistance ■ Capsule® Seat Minimal purge requirements Easily transported
■ 10 Micron Filtration Increased serviceability ■ Field-Adjustable Pressure Limit and integrated
in Both Stages and life Safeguard downstream
Failsafe seat performance equipment

Specifications Materials
■ Maximum Inlet Pressure ■ Ports ■ Body ■ Filter
3000 psig (210 bar) 1/4" FPT 316L stainless steel 10 micron multilayer,
■ Temperature Range ■ Helium Leak Integrity barstock sintered 316L stainless steel

-40 oF to 140 oF 1 x 10-8 scc/sec ■ Bonnet wire mesh (patented)


(-40 oC to 60 oC) ■ Cv Chrome-plated die cast zinc ■ Diaphragm
1-877-PRAXAIR

■ Gauges 0.1 ■ Seat 316L stainless steel


2" diameter stainless steel ■ Weight PTFE Teflon® ■ Internal Seals
4.8 lb (2.2 kg) PTFE Teflon®

Ordering Information – Series CON332ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA*
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections*
1: 0-15 psig 30"-0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body CGA,
2: 0-50 psig 30"-0-100 psig 3: 0-4000 psig 1: 1/4" MPT 1: Standard Assembly DIN 477,
3: 0-100 psig 30"-0-200 psig 5: 0-1000 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) BS 341
4: 0-250 psig 0-400 psig 6: 0-300 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly and others
7: 0-150 psig 30"-0-200 psig 7: 0-400 psig 4: Diaphragm Valve 1/4" MPT (bar/psi Gauges) available
5: Needle Valve 1/4" MPT
6: 1/8" Tube Fitting
7: 3/8" Tube Fitting * Not available with
8: Diaphragm Valve 1/8" Tube Fitting CGA330. Refer to
9: Diaphragm Valve 1/4" FPT 432 Series (page F8)

Option Part Number Description


Helium Leak Certification CON4760002 Inboard helium leak certification to less than 1 x 10-8 scc/sec
Protocol Station Add Letter “M” after CGA See page F35 for details
Protocol Switchover Station Add Letter “C” after CGA See page F36 for details
Protocol Switchover Station with Alarm Add Letter “G” after CGA See page F36 for details
Protocol Alarm Station Add Letter “A” after CGA See page F37 for details
Deep Purge Add Letter “D” after CGA See page F27 for details

F
14
GAS HANDLING EQUIPMENT
322 REGULATORS
High Purity Regulators for Corrosive Service

Single Stage 316L Stainless Steel Barstock Body,


Four-Port Configuration, 316L Stainless Steel
Diaphragm
The 322 Series regulators are intended for primary pressure
control of high purity and corrosive gases. It is recommended
for applications where minor fluctuations in outlet pressure due
to diminishing inlet supply can be tolerated.

Typical Applications
■ Gas and liquid ■ High purity chamber
chromatography pressurization
■ Ultra-high purity carrier gases ■ Liquefied hydrocarbon
■ Zero, span, and gas control

1-877-PRAXAIR
calibration gases ■ Control of cryogenic gases

Features and Benefits


■ 316L Stainless Steel ■ Pressure Ranges 0-15 ■ 316L Stainless Steel Diaphragm ■ Convoluted Diaphragm
Barstock Body to 0-500 psig No inboard diffusion Smooth pressure transition
Enhanced corrosion Broad range of applications ■ Low Wetted Volume ■ Compact Ergonomic Design
resistance ■ Capsule® Seat Minimal purge requirements Easily transported


■ Rear Panel Mountable Increased serviceability ■ Field-Adjustable Pressure Limit and integrated
Easy installation and life Safeguard downstream

www.praxair.com/specialtygases
equipment

Specifications Materials
■ Maximum Inlet Pressure ■ Ports ■ Body ■ Filter
3000 psig (210 bar) 1/4" FPT 316L stainless steel 10 micron multilayer,
■ Temperature Range ■ Helium Leak Integrity barstock sintered 316L stainless steel
-40 oF to 140 oF 1 x 10-8 scc/sec ■ Bonnet wire mesh (patented)
(-40 oC to 60 oC) ■ Cv Chrome-plated die cast zinc ■ Diaphragm
■ Gauges 0.1 ■ Seat 316L stainless steel
2" diameter stainless steel ■ Weight PTFE Teflon® ■ Internal Seals
(wetted) 3.2 lb (1.5 kg) PTFE Teflon®

Ordering Information – Series CON322ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA*
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connection*
1: 0-15 psig 30"-0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body CGA,
2: 0-50 psig 30"-0-100 psig 3: 0-4000 psig 1: 1/4" MPT 1: Standard Assembly DIN 477,
3: 0-100 psig 30"-0-200 psig 5: 0-1000 psig 2: 1/4" Tube Fitting psi/kPa Gauges) BS 341
4: 0-250 psig 0-400 psig 6: 0-300 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly and others
5: 0-500 psig 0-1000 psig 7: 0-400 psig 4: Diaphragm Valve 1/4" MPT (bar/psi Gauges) available
7: 0-150 psig 30"-0-200 psig 5: Needle Valve 1/4" MPT
6: 1/8" Tube Fitting
7: 3/8" Tube Fitting
* Not available with
8: Diaphragm Valve 1/8" Tube Fitting CGA330. Refer to
9: Diaphragm Valve 1/4" FPT 422 Series (page F9)

Option Part Number Description


Helium Leak Certification CON4760002 Inboard helium leak certification to less than 1 x 10-8 scc/sec
Protocol Station Add Letter “M” after CGA See page F35 for details
Protocol Switchover Station Add Letter “C” after CGA See page F36 for details
Protocol Switchover Station with Alarm Add Letter “G” after CGA See page F36 for details
Protocol Alarm Station Add Letter “A” after CGA See page F37 for details
Deep Purge Add Letter “D” after CGA See page F27 for details
F
15
GAS HANDLING EQUIPMENT
324 REGULATORS
High Purity Regulators for Corrosive Service

Line Regulator, Single Stage 316L Stainless Steel


Barstock Body, Three-Port Configuration,
316L Stainless Steel Diaphragm
The 324 Series regulators are intended for secondary pressure control
of high purity and corrosive gases. It is also recommended as point of
use pressure control in high purity gas delivery systems.

Typical Applications
■ Bulk gas delivery systems ■ High purity chamber
■ Gas and liquid pressurization
chromatography ■ Liquefied hydrocarbon
■ High purity carrier gases gas control
■ Zero, span, and ■ Control for cryogenic gases
www.praxair.com/specialtygases

calibration gases

Features and Benefits


■ 316L Stainless Steel ■ Pressure Ranges 0-15 ■ 316L Stainless Steel Diaphragm ■ Convoluted Diaphragm
Barstock Body to 0-500 psig No inboard diffusion Smooth pressure transition
Enhanced corrosion Broad range of applications ■ Low Wetted Volume ■ Compact Ergonomic Design
resistance ■ 3000 psig Inlet Pressure Rating Minimal purge requirements Easily transported
■ Rear Panel Mountable Safe use with high ■ Field-Adjustable Pressure Limit and integrated
Easy installation pressure cylinders Safeguard downstream
■ Capsule® Seat equipment
Increased serviceability
and life

Specifications Materials

■ Maximum Inlet Pressure ■ Ports ■ Body ■ Filter


3000 psig (210 bar) 1/4" FPT 316L stainless steel 10 micron multilayer,
1-877-PRAXAIR

■ Temperature Range ■ Helium Leak Integrity barstock sintered 316L stainless steel
-40 oF to 140 oF 1 x 10-8 scc/sec ■ Bonnet wire mesh (patented)
(-40 oC to 60 oC) ■ Cv Chrome-plated die cast zinc ■ Diaphragm
■ Gauges 0.1 ■ Seat 316L stainless steel
2" diameter ■ Weight PTFE Teflon® ■ Internal Seals
chrome-plated brass 2.8 lb (1.3 kg) PTFE Teflon®

Ordering Information – Series CON324ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 30"-0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body 000: 1/4" FPT
2: 0-50 psig 30"-0-100 psig 1: 1/4" MPT 1: Standard Assembly TF2: 1/8" Tube
3: 0-100 psig 30"-0-200 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) TF4: 1/4" Tube
4: 0-250 psig 0-400 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly TF6: 3/8" Tube
5: 0-500 psig 0-1000 psig 4: Diaphragm Valve 1/4" MPT (bar/psi Gauges)
7: 0-150 psig 30"-0-200 psig 5: Needle Valve 1/4" MPT
6: 1/8" Tube Fitting
7: 3/8" Tube Fitting
8: Diaphragm Valve 1/8" Tube Fitting
9: Diaphragm Valve 1/4" FPT

Option Part Number Description


Helium Leak Certification CON4760002 Inboard helium leak certification to less than 1 x 10-8 scc/sec

F
16
GAS HANDLING EQUIPMENT
212 REGULATORS
High Purity Economical Regulators

Dual Stage Chrome-Plated Forged Brass Body,


Five-Port Configuration, 316L Stainless Steel Diaphragm
The 212 Series regulators are intended for primary pressure control
of non-corrosive, high purity or liquefied gases. It is recommended for
applications requiring constant delivery pressure control, regardless
of supply pressure.

Typical Applications
■ Gas supply purging
■ Gas system charging
■ Fuel gas supply control
■ Calibration gas control

1-877-PRAXAIR
Features and Benefits
■ Chrome-Plated Forged ■ Pressure Ranges 0-15 ■ 316L Stainless Steel Diaphragm ■ Large Convoluted Diaphragm
Brass Body to 0-200 psig No inboard diffusion Smooth pressure transition
Economical high Broad range of applications ■ Forged Body ■ Standard Relief Valve
purity design ■ 10 Micron Filtration Durable, long-lasting Diaphragm and
■ High Flow Capacity in Both Stages construction gauge protection
Supply multiple Failsafe seat performance ■ Field-Adjustable Pressure Limit


use locations ■ Capsule® Seat Safeguard downstream
Increased serviceability equipment

www.praxair.com/specialtygases
and life

Specifications Materials
■ Maximum Inlet Pressure ■ Ports ■ Body ■ Filter
3000 psig (210 bar) 1/4" FPT Chrome-plated forged brass 10 micron multilayer,
4500 psig (300 bar) optional ■ Helium Leak Integrity ■ Bonnet sintered 316L stainless steel
■ Temperature Range 1 x 10-8 scc/sec Chrome-plated die cast zinc wire mesh (patented)
-40 oF to 140 oF ■ Cv ■ Seat ■ Diaphragm
(-40 oC to 60 oC) 0.28 PTFE Teflon® 316L stainless steel
■ Gauges ■ Weight PCTFE with 4500 psig ■ Internal Seals
2-1/2" diameter 6 lb (2.7 kg) inlet option PTFE Teflon®
chrome-plated brass

Ordering Information — Series CON212ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body CGA,
2: 0-40 psig 0-60 psig 3: 0-4000 psig 1: 1/4" MPT 1: Standard Assembly DIN 477,
3: 0-120 psig 0-200 psig 5: 0-1000 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) BS 341
4: 0-200 psig 0-400 psig 6: 0-400 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly and others
8: 0-6000 psig* 4: Diaphragm Valve 1/4" MPT (bar/psi Gauges) available
5: Needle Valve 1/4" MPT
6: 1/8" Tube Fitting
7: 3/8" Tube Fitting
* Maximum inlet pressure 4500 psig (300 bar) 8: Diaphragm Valve 1/8" Tube Fitting
with PCTFE Seat Capsule 9: Diaphragm Valve 1/4" FPT

Option Part Number Description


Protocol Station Add Letter “M” after CGA See page F35 for details
Protocol Switchover Station Add Letter “C” after CGA See page F36 for details
Protocol Switchover Station with Alarm Add Letter “G” after CGA See page F36 for details
Protocol Alarm Station Add Letter “A” after CGA See page F37 for details
Deep Purge Add Letter “D” after CGA See page F27 for details
F
17
GAS HANDLING EQUIPMENT
202 REGULATORS
High Purity Economical Regulators

Single Stage Chrome-Plated Forged Brass Body,


Five-Port Configuration, 316L Stainless Steel Diaphragm
The 202 Series regulators are intended for primary pressure control
of non-corrosive, high purity or liquefied gases. It is recommended
for applications where minor fluctuations in outlet pressure due to
diminishing inlet supply pressure can be tolerated.

Typical Applications
■ Gas supply purging ■ Calibration gas control
■ Gas system charging ■ Atomic absorption acetylene
■ Fuel gas supply control
www.praxair.com/specialtygases

Features and Benefits


■ Chrome-Plated Forged ■ Pressure Ranges 0-15 ■ Forged Body ■ Large Convoluted Diaphragm
Brass Body to 0-200 psig Durable, long-lasting Smooth pressure transition
Economical high Broad range of applications construction ■ Standard Relief Valve
purity design ■ Capsule® Seat ■ Field-Adjustable Pressure Limit Diaphragm and
■ High Flow Capacity Increased serviceability Safeguard downstream gauge protection
Supply multiple and life equipment
use locations ■ 316L Stainless Steel Diaphragm
No inboard diffusion

Specifications Materials
■ Maximum Inlet Pressure ■ Ports ■ Body ■ Filter
3000 psig (210 bar) 1/4" FPT Chrome-plated forged brass 10 micron multilayer,
4500 psig (300 bar) optional ■ Helium Leak Integrity ■ Bonnet sintered 316L stainless steel
■ Temperature Range 1 x 10-8 scc/sec Chrome-plated die cast zinc wire mesh (patented)

-40 oF to 140 oF ■ Cv ■ Seat ■ Diaphragm


(-40 oC to 60 oC) 316L stainless steel
1-877-PRAXAIR

0.2 PTFE Teflon®


■ Gauges ■ Weight PCTFE with 4500 psig ■ Internal Seals
2-1/2" diameter 4.25 lb (1.9 kg) inlet option PTFE Teflon®
chrome-plated brass

Ordering Information – Series CON202ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body CGA,
2: 0-40 psig 0-60 psig 3: 0-4000 psig 1: 1/4" MPT 1: Standard Assembly DIN 477,
3: 0-120 psig 0-200 psig 5: 0-1000 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) BS 341
4: 0-200 psig 0-400 psig 7: 0-400 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly and others
5: 0-15 psig* 0-30 psig** 8: 0-6000 psig*** 4: Diaphragm Valve 1/4" MPT (bar/psi Gauges) available
5: Needle Valve 1/4" MPT
* Not available with 4500 psig inlet pressure 6: 1/8" Tube Fitting
** With red line for acetylene use 7: 3/8" Tube Fitting
*** Maximum inlet pressure 4500 psig (300 bar) 8: Diaphragm Valve 1/8" Tube Fitting
with PCTFE Seat Capsule 9: Diaphragm Valve 1/4" FPT

Option Part Number Description


Protocol Station Add Letter “M” after CGA See page F35 for details
Protocol Switchover Station Add Letter “C” after CGA See page F36 for details
Protocol Switchover Station with Alarm Add Letter “G” after CGA See page F36 for details
Protocol Alarm Station Add Letter “A” after CGA See page F37 for details
Deep Purge Add Letter “D” after CGA See page F27 for details

F
18
GAS HANDLING EQUIPMENT
205 REGULATORS
High Purity Economical Regulators

Line Regulator, Single Stage Chrome-Plated


Forged Brass Body, Four-Port Configuration,
316L Stainless Steel Diaphragm
The 205 Series regulators are intended for secondary pressure
control of non-corrosive, high purity or liquefied gases. It is also
recommended as point of use pressure control in high purity gas
delivery systems.

Typical Applications
■ Point of use laboratory ■ Control of cryogenic gases
systems ■ Bulk gas distribution systems
■ Gas supply purging

1-877-PRAXAIR
■ Liquefied hydrocarbon
gas control

Features and Benefits


■ Chrome-Plated Forged ■ Pressure Ranges 0-15 ■ 316L Stainless Steel Diaphragm ■ Large Convoluted Diaphragm
Brass Body to 0-200 psig No inboard diffusion Smooth pressure transition
Economical Broad range of applications ■ Forged Body ■ Standard Relief Valve


high purity design ■ 3000 psig Inlet Pressure Rating Durable, long-lasting Diaphragm and
■ High Flow Capacity Safe use with high construction gauge protection

www.praxair.com/specialtygases
Supply multiple pressure cylinders ■ Field-Adjustable Pressure Limit
use locations ■ Capsule® Seat Safeguard downstream
Increased serviceability equipment
and life

Specifications Materials
■ Maximum Inlet Pressure ■ Ports ■ Body ■ Filter
3000 psig (210 bar) 1/4" FPT Chrome-plated forged brass 10 micron multilayer,
■ Temperature Range ■ Helium Leak Integrity ■ Bonnet sintered 316L stainless steel
-40 oF to 140 oF 1 x 10-8 scc/sec Chrome-plated die cast zinc wire mesh (patented)
(-40 oC to 60 oC) ■ Cv ■ Seat ■ Diaphragm
■ Gauges 0.2 PTFE Teflon® 316L Stainless Steel
2-1/2" diameter ■ Weight ■ Internal Seals
chrome-plated brass 4.25 lb (1.9 kg) PTFE Teflon®

Ordering Information – Series CON205ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body 000: 1/4" FPT
2: 0-40 psig 0-60 psig 1: 1/4" MPT 1: Standard Assembly TF2: 1/8" Tube
3: 0-120 psig 0-200 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) TF4: 1/4" Tube
4: 0-200 psig 0-400 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly TF6: 3/8" Tube
5: 0-15 psig 0-30 psig* 4: Diaphragm Valve 1/4" MPT (bar/psi Gauges)
5: Needle Valve 1/4" MPT
6: 1/8" Tube Fitting
7: 3/8" Tube Fitting
8: Diaphragm Valve 1/8" Tube Fitting
* With red line acetylene use 9: Diaphragm Valve 1/4" FPT

Option Part Number Description


Reversed Inlet/Outlet Configuration Contact Praxair Inlet and outlet ports supplied in a reversed ("mirror image") configuration

F
19
GAS HANDLING EQUIPMENT
109 REGULATORS
General Purpose Regulators

Single and Dual Stage Forged Brass Body,


Five-Port Configuration, Teflon®-Coated
Neoprene Diaphragm
The 109 Series regulators are intended for pressure control of general
purpose laboratory gases with applications requiring constant delivery
pressure, regardless of supply pressure.

Typical Applications
■ Purging
■ Pressure testing
■ Blanketing Shown with
■ Chamber pressurization needle valve
www.praxair.com/specialtygases

Features and Benefits


■ Forged Brass Body ■ Pressure Ranges 0-15 ■ Teflon®-lined Neoprene ■ Field-Adjustable Pressure Limit
Economical high to 0-200 psig Diaphragm Safeguard downstream
purity design Broad range of Sensitive to downstream equipment
■ 10 Micron Filtration applications conditions ■ Integral Relief Valve
in Both Stages ■ Capsule® Seat ■ Forged Body Diaphragm and
Failsafe seat Increased serviceability Durable, long-lasting gauge protection
performance and life construction ■ High Flow Capacity
Supply multiple
use locations

Specifications Materials
■ Maximum Inlet Pressure ■ Helium Leak Integrity ■ Body ■ Filter

3000 psig (210 bar) (Single Stage) Forged brass 10 micron multilayer,
Temperature Range 1 x 10-8 scc/sec Bonnet sintered 316L stainless steel
1-877-PRAXAIR

■ ■
-40 oF to 140 oF ■ Cv Brass-plated die cast zinc wire mesh (patented)
(-40 oC to 60 oC) 0.28 (dual stage) ■ Seat ■ Diaphragm
■ Gauges 0.2 (single stage) PTFE Teflon® Teflon®-lined neoprene
2-1/2" diameter brass ■ Weight ■ Internal Seals
■ Ports 5.3 lb (2.4 kg) – dual stage PTFE Teflon®
1/4" FPT 3.8 lb (1.7 kg) – single stage

Ordering Information – Series CON10975 (Dual Stage)


Series CON10965 (Single Stage)*
Part Number Oulet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies
CON1097501-CGA 0-15 psig 0-30 psig 0-4000 psig 1/4" Tube Fitting
CON1097502-CGA 0-15 psig 0-30 psig 0-4000 psig Needle Valve 1/4" MPT
CON1097504-CGA 0-40 psig 0-60 psig 0-4000 psig 1/4" Tube Fitting
CON1097505-CGA 0-40 psig 0-60 psig 0-4000 psig Needle Valve 1/4" MPT
CON1097512-CGA 0-120 psig 0-200 psig 0-4000 psig 1/4" Tube Fitting
CON1097513-CGA 0-120 psig 0-200 psig 0-4000 psig Needle Valve 1/4" MPT
CON1097520-CGA 0-200 psig 0-400 psig 0-4000 psig 1/4" Tube Fitting
CON1097521-CGA 0-200 psig 0-400 psig 0-4000 psig Needle Valve 1/4" MPT
* Note: Replace 75 with 65 for Single Stage

Option Part Number Description


Protocol Station Add Letter “M” after CGA See page F35 for details
Protocol Switchover Station Add Letter “C” after CGA See page F36 for details
Protocol Switchover Station with Alarm Add Letter “G” after CGA See page F36 for details
Protocol Alarm Station Add Letter “A” after CGA See page F37 for details
F Deep Purge Add Letter “D” after CGA See page F27 for details
20
GAS HANDLING EQUIPMENT
206 REGULATORS
Special Purpose Regulators for Liquid Containers

Single Stage Chrome-Plated Forged Brass Body,


316L Stainless Steel Diaphragm, Liquid Cylinder
Regulator
The 206 Series regulators are intended for primary pressure
control of gases supplied in cryogenic liquid cylinders.

Typical Applications
■ Argon
■ Nitrogen
■ Oxygen
■ Carbon Dioxide
■ Certain Halocarbons

1-877-PRAXAIR
Features and Benefits
■ Designed for Low ■ 3000 psig Inlet Pressure Rating ■ Forged Body ■ Large Convoluted Diaphragm
Inlet Pressures Safe use on high Durable, long-lasting Smooth pressure transition
Optimized flow with pressure cylinders construction ■ Standard Relief Valve
liquid cylinders ■ Capsule® Seat ■ Field-Adjustable Pressure Limit Diaphragm and
■ Large Capsule® Seat Increased serviceability Safeguard downstream gauge protection


Permits flow rates and life equipment

www.praxair.com/specialtygases
unobtainable with ■ 316L Stainless Steel Diaphragm
conventional regulators No inboard diffusion

Specifications Materials
■ Maximum Inlet Pressure ■ Ports ■ Body ■ Filter
3000 psig (210 bar) 1/4" FPT Chrome-plated forged brass 10 micron multilayer,
■ Temperature Range ■ Helium Leak Integrity ■ Bonnet sintered 316L stainless steel
-40 oF to 140 oF 1 x 10-8 scc/sec Chrome-plated die cast zinc wire mesh (patented)
(-40 oC to 60 oC) ■ Cv ■ Seat ■ Diaphragm
■ Gauges 0.2 PTFE Teflon® 316L stainless steel
2-1/2" diameter ■ Weight ■ Internal Seals
chrome-plated brass 4.25 lb (1.9 kg) PTFE Teflon®

Ordering Information – Series CON206ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body CGA,
2: 0-40 psig 0-60 psig 1: 1/4" MPT 1: Standard Assembly DIN 477,
3: 0-120 psig 0-200 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) BS 341
4: 0-200 psig 0-400 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly Limited by
4: Diaphragm Valve 1/4" MPT (bar/psi Gauges) gas service
5: Needle Valve 1/4" MPT
6: 1/8" Tube Fitting
7: 3/8" Tube Fitting
8: Diaphragm Valve 1/8" Tube Fitting
9: Diaphragm Valve 1/4" FPT

Option Part Number Description


Protocol Station Add Letter “M” after CGA See page F35 for details
Protocol Switchover Station Add Letter “C” after CGA See page F36 for details
Protocol Switchover Station with Alarm Add Letter “G” after CGA See page F36 for details
Protocol Alarm Station Add Letter “A” after CGA See page F37 for details
Deep Purge Add Letter “D” after CGA See page F27 for details
F
21
GAS HANDLING EQUIPMENT
308 REGULATORS
Special Purpose Regulators – Electrically Heated

Single Stage Chrome-Plated Brass Barstock Body,


316L Stainless Steel Diaphragm, Electrically Heated
for Carbon Dioxide and Nitrous Oxide
The 308 Series regulators are specially designed to prevent
freeze-up problems associated with high flows of carbon dioxide
and nitrous oxide.

Typical Applications
■ Chemical storage blanketing ■ Semiconductor reactor
■ Anaerobic chambers furnace
■ Inert gas purging ■ Inductively coupled
plasma systems
■ Atomic absorption
www.praxair.com/specialtygases

oxidizer gas ■ Ph control

Features and Benefits


■ Chrome-Plated Brass ■ 316L Stainless Steel Diaphragm ■ 316L Stainless Steel Diaphragm ■ Convoluted Diaphragm
Barstock Body Unaffected by low No inboard diffusion Smooth pressure transition
Smooth surface finish temperatures ■ Low Wetted Volume ■ Compact Ergonomic Design
■ Three 50 Watt Heaters ■ Capsule® Seat Minimal purge requirements Easily transported
Maintain gas flow Increased serviceability ■ Field-Adjustable Pressure Limit and integrated
up to 350 scfh and life Safeguard downstream
equipment

Specifications Materials
■ Maximum Inlet Pressure ■ Gauges ■ Body ■ Filter
3000 psig (210 bar) 2" diameter Chrome-plated brass 10 micron multilayer,
chrome-plated brass barstock sintered 316L stainless steel

■ Temperature Range
(Thermostat) ■ Ports ■ Bonnet wire mesh (patented)
1-877-PRAXAIR

95 oF to 120 oF 1/4" FPT Chrome-plated die cast zinc ■ Diaphragm


(35 oC to 48 oC) ■ Helium Leak Integrity ■ Seat 316L stainless steel
■ Heaters 1 x 10-8 scc/sec PTFE Teflon® ■ Internal Seals
3 @ 50 watts each ■ Cv PTFE Teflon®
(110 or 220 VAC) 0.1
■ Weight
3.5 lb (1.6 kg)

Ordering Information – Series CON308ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 0-30 psig 0: None 0: 1/4" FPT Port 0: 110 VAC Bare Body CGA,
2: 0-30 psig 0-60 psig 3: 0-4000 psig 1: 1/4" MPT 1: 110 VAC DIN 477,
3: 0-50 psig 0-100 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) BS 341
5: 0-100 psig 0-200 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: 220 VAC Bare Body Limited by
4: Diaphragm Valve 1/4" MPT 3: 220 VAC gas service
5: Needle Valve 1/4" MPT (psi/kPa Gauges)
6: 1/8" Tube Fitting 4: 110 VAC
(bar/psi Gauges)
5: 220 VAC
(bar/psi Gauges)

Option Part Number Description


Protocol Station Add Letter “M” after CGA See page F35 for details
Protocol Switchover Station Add Letter “C” after CGA See page F36 for details
Protocol Switchover Station with Alarm Add Letter “G” after CGA See page F36 for details
F Protocol Alarm Station Add Letter “A” after CGA See page F37 for details
22 Deep Purge Add Letter “D” after CGA See page F27 for details
GAS HANDLING EQUIPMENT
325 REGULATORS
Special Purpose Regulators for Lecture Bottles

Single Stage Chrome-Plated Brass Barstock Body,


316L Stainless Steel Diaphragm, Lecture Bottles
The 325 Series regulators are specifically designed for use with
non-corrosive gases in lecture bottles. The incorporation of the
smallest Capsule® allows excellent pressure regulation over the
useful pressure range of a lecture bottle.

Typical Applications
■ University classrooms
■ University laboratories
■ Chemical research
■ Pharmaceutical manufacturing

1-877-PRAXAIR
Features and Benefits
■ Chrome-Plated Brass ■ 1 1/2" Pressure Gauges ■ Low Wetted Volume ■ Convoluted Diaphragm
Barstock Body Small envelope Minimal purge requirements Smooth pressure changes
Smooth surface finish ■ Capsule® Seat ■ Field-Adjustable Pressure Limit ■ Compact Design
■ Low Droop Increased serviceability Safeguard downstream Easily transported
Stable outlet pressure and life equipment and integrated


■ 316L Stainless Steel Diaphragm

www.praxair.com/specialtygases
No inboard diffusion

Specifications Materials
■ Maximum Inlet Pressure ■ Helium Leak Integrity ■ Body ■ Filter
3000 psig (210 bar) 1 x 10-8 scc/sec Chrome-plated brass 10 micron multilayer,
■ Temperature Range ■ Pressure Increase/ barstock sintered 316L stainless steel
-40 oF to 140 oF 100 psig Input Decrease ■ Bonnet wire mesh (patented)
(-40 oC to 60 oC) 0.19 psig @ 35 cfh N2 Chrome-plated ■ Diaphragm
■ Gauges initial flow die cast zinc 316L stainless steel
1-1/2" diameter ■ Cv ■ Seat ■ Internal Seals
chrome-plated brass 0.02 PTFE Teflon® PTFE Teflon®
■ Ports ■ Weight
1/8" FPT 2.3 lb (1.0 kg)
(1/4" FPT relief valve)

Ordering Information – Series CON325ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 0-30 psig 0: None 1: 1/8" FPT Port 1: Standard Assembly CGA 170,
2: 0-50 psig 0-100 psig 3: 0-4000 psig 5: Needle Valve 1/8" MPT (psig/kPa Gauges) CGA 180
and others
available

F
23
GAS HANDLING EQUIPMENT
408 REGULATORS
Special Purpose Regulators for Corrosive Service

Single Stage Anodized Aluminum Barstock Body,


316L Stainless Steel Diaphragm
The 408 Series regulators are intended for primary pressure control of mildly
corrosive high purity gases such as ammonia, hydrogen sulfide, and sulfur dioxide
or for applications requiring the lightweight of an aluminum body regulator.

Typical Applications
■ Semi-corrosive gases and mixtures ■ Zero, span, and calibration gases
■ Gas and liquid chromatography ■ High purity chamber pressurization
■ High purity carrier gases

Features and Benefits


■ Anodized Aluminum Body ■ Metal-to-Metal Diaphragm Seal ■ Low Wetted Volume
www.praxair.com/specialtygases

Cost-effective corrosion resistance No possibility of gas contamination Minimal purge requirements


■ Front and Rear Panel Mountable ■ Capsule® Seat ■ Field-Adjustable Pressure Limit
Versatile system configuration Increased serviceability and life Safeguard downstream equipment
■ Pressure Ranges 0-15 to 0-500 psig ■ 316L Stainless Steel Diaphragm ■ Pipe Away Relief Valve
Broad range of applications No inboard diffusion Safely vent exhausted gases
■ Orientable Captured Vent Capable
Safe and easy installation

Specifications Materials More Common Gases


■ Maximum Inlet Pressure ■ Body Gas Service Inlet Pressure
3000 psig (210 bar) Anodized aluminum barstock Ammonia 114 psig
■ Temperature Range ■ Bonnet Carbonyl Sulfide 160 psig
-40 oF to 140 oF (-40 oC to 60 oC) Anodized aluminum barstock Dimethylamine 11.3 psig
■ Ports ■ Filter Hydrogen Sulfide 252 psig
1/4" FPT 10 micron multilayer, sintered Methyl Mercaptan 15 psig
■ Helium Leak Integrity 316L stainless steel wire mesh (patented) Monomethylamine 29 psig
1 x 10-9 scc/sec ■ Seat Sulfur Dioxide 34 psig

■ Cv PTFE Teflon® Trimethylamine 13.3 psig


0.1 ■ Diaphragm Vinyl Chloride 30 psig
1-877-PRAXAIR

■ Weight 316L stainless steel Vinyl Fluoride 355 psig


2.1 lb (1.0 kg) ■ Internal Seals Vinyl Methyl Ether 28 psig
PTFE Teflon® Mixtures <3000 psig

Ordering Information – Series CON408ABCD-CGA Highlighted selection indicates most popular model
A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 30"-0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body CGA,
2: 0-50 psig 30"-0-100 psig 3: 0-4000 psig 1: 1/4" MPT 1: Standard Assembly DIN477,
3: 0-100 psig 30"-0-200 psig 5: 0-1000 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) BS341
4: 0-250 psig 0-400 psig 6: 0-300 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly and others
5: 0-500 psig 0-1000 psig 7: 0-400 psig 4: Diaphragm Valve 1/4" MPT (bar/psi Gauges) available
7: 0-150 psig 30"-0-200 psig 5: Needle Valve 1/4" MPT
6: 1/8" Tube Fitting
7: 3/8" Tube Fitting
8: Diaphragm Valve 1/8" Tube Fitting
9: Diaphragm Valve 1/4" FPT

Option Part Number Description


Panel Mount Kit CON5500002 To mount the regulator using threads on the bonnet. Material: Nickel-plated brass
Captured Vent Kit CON5500001 Orientable 360o for easy piping of vented gases to a safe location in the event of
diaphragm failure. Material: Nickel-plated Brass
Helium Leak Certification CON4760002 Inboard helium leak certification to less than 1 x 10-8 scc/sec
Protocol Station Add Letter “M” after CGA See page F35 for details
Protocol Switchover Station Add Letter “C” after CGA See page F36 for details
Protocol Switchover Station with Alarm Add Letter “G” after CGA See page F36 for details
Protocol Alarm Station Add Letter “A” after CGA See page F37 for details Praxair recommends
Deep Purge Add Letter “D” after CGA See page F27 for details the use of purge
F assemblies in corrosive
24 gas applications
(see page F27)
GAS HANDLING EQUIPMENT
455 REGULATORS
Special Purpose Regulators for Corrosive Service

Single Stage Electroless Nickel-Plated Forged


Brass Body, 316L Stainless Steel Diaphragm
The 455 Series regulators are intended for primary pressure
control of highly corrosive gases such as chlorides, sulfides,
and other acid-forming gases.

Features and Benefits


■ Nickel-Plated Forged ■ High Load Marginal Spring
Brass Body Positive Seat Closure
Durable, long-lasting ■ Capsule® Seat
construction Serviceability and long life
■ Convoluted 316L Stainless ■ Captured Vent Capable
Steel Diaphragm Safely vent exhaust gases

1-877-PRAXAIR
Sensitive to downstream
changes ■ Hastelloy® Seat Assembly
Superior corrosion
resistance

Specifications Deep Purge


■ Maximum Inlet Pressure ■ Gauges ■ Cv For safety and corrosion pre-
3000 psig (210 bar) 2-1/2" diameter Monel® 0.2 vention, Praxair recommends the
addition of a Deep Purge assem-


■ Temperature Range ■ Ports ■ Weight
-40 oF to 140 oF 1/4" FPT (gauges) 4.5 lb (2.1 kg) bly to the 455 Series regulator

www.praxair.com/specialtygases
(-40 oC to 60 oC) ■ Helium Leak Integrity 6.5 lb (3.0 kg) (see page F27). Completely pur-
1 x 10-9 scc/sec with Deep Purge ging a system avoids the release
of hazardous gases into the
workplace. In addition, the Deep
Materials
Purge prevents the introduction
■ Body ■ Seat ■ Internal Seals of moisture to the regulator (moi-
Electroless nickel-plated PTFE Teflon® PTFE Teflon® sture will form acids in the body
forged brass ■ Nozzle ■ Filter of the regulator, which will result
■ Bonnet Hastelloy® 10 Micron sintered hastelloy in corrosion).
Electroless nickel-plated ■ Diaphragm
forged brass 316L stainless steel

Ordering Information – Series CON455ABCD-CGA Highlighted selection indicates most popular model

A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 30"-0-30 psig 0: None 0: 1/4" FPT Port 0: Bare Body CGA,
2: 0-40 psig 30"-0-100 psig 3: 0-4000 psig 1: 1/4" MPT 1: Standard Assembly DIN 477,
3: 0-120 psig 0-600 psig 5: 0-1000 psig 2: 1/4" Tube Fitting (psig/kPa Gauges) BS 341
4: 0-200 psig 0-600 psig 6: 0-300 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly and others available
7: 0-100 psig 4: Diaphragm Valve 1/4" MPT with Deep Purge
8: 0-30 psig 5: Needle Valve 1/4" MPT (Monel®) (psig/kPa Gauges)
6: 1/8" Tube Fitting
7: 3/8" Tube Fitting
9: Diaphragm Valve 1/4" FPT

Option Part Number Description


Special treatment CON5500003 Regulator passivation for fluorine service

Praxair recommends
the use of purge
assemblies in corrosive
gas applications
F
(see page F27)
25
GAS HANDLING EQUIPMENT
ASB REGULATORS
Special Purpose Regulators for Corrosive Service

Single Stage, Tied Seat, High Purity Regulators for


Acid-Forming Gases (Model ASB)
The Model ASB regulator has been specifically designed for use
with acid-forming gases such as hydrogen chloride or boron
trifluoride. It is constructed primarily of aluminum-silicon-bronze
metal, which has shown superior corrosion-resistant properties in
these demanding services.
The ASB also features a Monel® nozzle and Monel® filter screens,
along with a stainless steel diaphragm which has been lined with
Hastelloy C-22®. This combination allows for its use in high purity
Special
applications, Purpose
while Regulators
also enhancing for
its resistance to Corrosive
corrosion. Service

Features and Benefits Optional Features


■ Aluminum-silicon-bronze ■ Tied seat (tied diaphragm) ■ Bonnet vent connector pro- ■ External (outboard) helium
www.praxair.com/specialtygases

construction provides superior ensures positive shutoff if vides a 1/8" FPT port allow- leak test and test report
corrosion resistance to acid- particulate matter should ing bonnet to be connected determines leak rate of gas
forming gases such as HCl. lodge in the seat, a common to a vent line or disposal from regulator to atmosphere;
■ Stainless steel diaphragm problem with corrosive gases. system as precaution in the test report certifies leak rate
lined with Hastelloy C-22® ■ Threaded holes in rear of unlikely event of a diaphragm of less than 5 x 10-7 sccs air
maintains gas purity while regulator permit front panel failure. equivalent.
also providing enhanced mounting. ■ Internal (inboard) helium leak
resistance to corrosion. ■ Aluminum-silicon bronze test and test report deter
■ High purity regulator design diaphragm seal outlet valve mines inboard leak rate; test
permits vacuum purging of maintains gas purity. report certifies leak rate of
regulator. less than 2 x 10-8 sccs air
equivalent.

Specifications Materials
■ Maximum Inlet Pressure ■ Flow Coefficient ■ Body and Outlet Valve ■ Seats (Regulator and

See Ordering Information Regulator: Cv = 0.624 Aluminum Silicon Bronze Outlet Valve)
Outlet Valve: Cv = 0.26 PCTFE
1-877-PRAXAIR

■ Inlet Pressure Gauge ■ Gauges


See Ordering Information ■ Inlet Connection Type 316 Stainless Steel ■ Diaphragm
■ Delivery Pressure Range CGA 330, 350, or 660 ■ Bonnet Type 316 Stainless Steel lined
See Ordering Information as ordered Nickel-Chrome Plated Brass with Hastelloy C-22®

■ Delivery Pressure Gauge ■ Outlet Connection ■ Other Metal Parts ■ Seals


See Ordering Information 1/4" FPT (on outlet valve) Exposed to Gas Teflon®

■ Gauge Size ■ Supply Pressure Effect Type 316 Stainless Steel,


2-1/2" Dial 1 psi per 100 psi (approximate) Monel®, and Inconel®
■ Approximate Weight
7 lb (3.2 kg)
Praxair recommends
the use of purge
Ordering Information assemblies in corrosive
Inlet Pressure (psig) Delivery Pressure (psig)
gas applications
(see page F27)
Part Number Maximum Gauge Range Gauge
ADVASB3-75-CGA 3000 0-4000 3-75 0-100
ADVASB3-150-CGA 3000 0-4000 10-150 0-200
ADVASB2-75-CGA 800 0-1000 3-75 0-100
ADVASB2-150-CGA 800 0-1000 10-150 0-200
ADVASB1-75-CGA 300 0-400 3-75 0-100
ADVASB1-150-CGA 300 0-400 10-150 0-200
ADVASB0-75-CGA 3000 none 3-75 0-100
ADVASB0-150-CGA 3000 none 10-150 0-200

Option Part Number Option Reference


Bonnet vent connector* ADVSG5647V Check valves* See page F113
Inboard helium leak test and test report ADVHT1000 Purge assemblies* See page F27
F Outboard helium leak test and test report ADVHT1001 (Cross purge assemblies are recommended)
26 * If selected, these items are not installed on the regulator. They are shipped as separate items.
GAS HANDLING EQUIPMENT
502 REGULATORS
Purge Assemblies

502 Series Purge Assemblies


Deep Purge, Tee Purge, Straight Purge
The 502 Series purges are designed for use with high purity gases
to insure system integrity upon break-down of components or during
gas source changes. Most commonly, these purge assemblies are
used with pressure control devices as an integral option or can be
used within gas delivery systems to isolate pressure or flow control
equipment.
The 502 Series purges are offered in brass and stainless steel.
Brass and stainless steel purges are offered only with diaphragm
valves. Optional testing can be provided to certify these purge
assemblies are helium leak-tight for the most demanding services.
These devices are intended for use with chemicals that are com-
patible with the listed materials.
Deep

1-877-PRAXAIR
Purge
Specifications
■ Maximum Pressure ■ Body
3000 psig (20,700 kPa) Brass purge: Brass barstock
■ Weight SS purge: 316 stainless steel
Deep purge: 3.0 lb (1.4 kg) ■ Diaphragms (purge valves)
Tee purge: 2.5 lb (1.1 kg) Brass purge: Elgiloy
Straight purge: 1.2 lb (0.6 kg) SS purge:
BeCu and stainless steel


■ Seat
KEL-F®

www.praxair.com/specialtygases
Materials Tee
■ Diaphragms (center valves) ■ Stem Purge
BeCu 304 Stainless steel
316 Stainless steel ■ Cv
■ Spring .27
304 Stainless steel

Ordering Information – Series CON502


Part Number Description
CON5023007-CGA Deep Purge, Brass
CON5023009-CGA Deep Purge, Stainless Steel
CON5022003-CGA Tee Purge, Brass
CON5022005-CGA Tee Purge, Stainless Steel Straight
Purge
CON5021002-CGA Straight Purge, Brass
CON5021005-CGA Straight Purge, Stainless Steel

Option Part Number Description


Helium Leak Certification CON 476-0002 Inboard helium leak certification to less than 1 x 10-8 scc/sec

F
27
GAS HANDLING EQUIPMENT
9000 REGULATORS
Regulators for Very Low Delivery Pressure

Dual Stage Cylinder Regulators For Very Low Delivery Pressures (Model TSC)
The Model TSC Regulator provides highly accurate pressure reduction of inlet pressures up to
3000 psig down to delivery pressures as low as 0.3 to 3 psig. The dual stage design provides
constant outlet pressure regardless of changes in cylinder (inlet) pressures. The Model TSC is
suitable for use with non-corrosive gases where high puirty is not required. Typical applications
include low pressure purging, inert blanketing of chemical or flammable storage units, or control
of fuel to burners.

Features and Benefits


■ Large 3" diaphragm in second ■ Two-stage regulator design ■ Pressure relief valve protects
stage, allows for accurate ensures constant delivery regulator from over-pressur-
control of delivery pressures pressure. ization.
down to 0.3 psig. ■ Sintered metal filters trap for- ■ Outlet metering valve provides
eign matter, extend regulator flow control.
life, and reduce maintenance.

Specifications Materials
www.praxair.com/specialtygases

■ Maximum Inlet Pressure ■ Operating Temperature Range ■ Body and Outlet Valve ■ Seats
3000 psig -20 oF to + 140 oF Forged Brass First Stage: PCTFE
■ Inlet Pressure Gauge ■ Relief Valve Setting (interstage) ■ Gauges Second Stage: Viton ®
0-4000 psig 150–225 psig Brass Internals with Draw ■ Diaphragms
■ Delivery Pressure Range ■ Inlet Connection Steel Case Viton ®
0.3–3 psig CGA 296, 346, 350, 510, 540, ■ Other Metal Parts Exposed ■ Seals
■ Gauge Size: 2-1/2" Dial 580, 590, 660 as ordered. to Gas Regulator: Viton®
■ Flow Coefficient ■ Outlet Connection Brass and Stainless Steel Outlet Valve: Teflon®
Regulator: Cv = 0.2 1/4" MPT (on outlet valve)
Outlet Valve: Cv = 0.35 ■ Approximate Weight: 7 lb

Ordering Information – Option Description Part Number


Series ADVTSC Compression Fittings* 1/4" NPT female x 1/8" compression ADVSG6723
Part Number ADVTSC-CGA (female connectors) 1/4" NPT female x 1/4" compression ADVSG6724
Check Valves* See page F113
* If selected, these items are not installed on the regulator. They are shipped as separate items.

Single Stage Regulators For Very Low Delivery Pressures (Model SSC) SSC
1-877-PRAXAIR

This regulator provides accurate control at very low delivery pressures. It is available in Regulator
five separate delivery pressure ranges: from 3.5"–8" H2O to 10–15 psig. Model SSC is
mainly designed for use with liquefied hydrocarbons such as Propane, Butane or Isobutane.
Although primarily used as a line regulator, it may be optionally ordered as a cylinder regulator
for use with gases having cylinder pressures below 250 psig. For high pressure cylinder
service (e.g., Nitrogen or Argon) in applications requiring very low delivery pressures
please refer to our Model TSC Regulator above. Warning: Do not use this regulator in
Hydrogen, Helium or Oxygen service.

Features and Benefits Specifications Materials


■ Large Diaphragm allows for ■ Maximum Inlet Pressure ■ Body and Bonnet Optional Pressure
accurate control of delivery 250 psig* Die Cast Zinc Adjusting Wrench
pressures as low as 3.5" H2O. ■ Minimum Inlet Pressure: 5 psig ■ Outlet Block, Outlet Valve
■ Threaded Mounting Pads ■ Delivery Pressure Range and Gauge
with screws permit panel See Ordering Information Brass
mounting. ■ Gauge Size: 2-1/2" Dial ■ Other Metal Parts Exposed
■ Outlet Metering Valve provides ■ Inlet Connection: 1/4" FPT to Gas
flow control. (CGA 510 cylinder connection Zinc, Brass and Stainless Steel
■ 2-1/2" Gauge reads easily for see Optional Equipment) ■ Diaphragm and Seat
more precise settings. ■ Outlet Connection Buna-N®
1/4" MPT (on outlet valve) ■ Seals
■ Approximate Weight: 4 lb Buna-N® and Teflon®

Ordering Information – Series ADVSSC Option Part Number


Delivery Pressure (psig) Pressure adjusting wrench ADVSG6216
Part Number Range Gauge CGA 510 cylinder connection Suffix Regulator part number with 510
ADVSSC-0* 3.5-8" H2O 0-35" H2O installed on inlet. Example: ADVSSC-5-510
ADVSSC-1* 0.5-1.0 0-32 oz.
ADVSSC-5 1.1-5.0 0-10
F ADVSSC-10 5.1-10.0 0-30
28 ADVSSC-15 10.1-15.0 0-30
* These models require inlet pressure below 100 psig to be able to provide
the full delivery pressure range.
GAS HANDLING EQUIPMENT
470 and 480 REGULATORS
Special Purpose Back Pressure Regulators

Brass Barstock Body (470 Series)


316L Stainless Steel Barstock Body (480 Series)
316L Stainless Steel Diaphragm
The 470 (Brass) and 480 (316L Stainless Steel) Series regulators
are intended for upstream or inlet pressure control in non-corrosive
(470 Series) and corrosive (480 Series), high purity applications.
Typically, these regulators are used to provide precise back
pressure control

Typical Applications
■ Fluid sampling systems ■ Research and development
■ Storage vessels laboratories
■ Gas chromatography ■ Compressors

1-877-PRAXAIR
■ Pump pressure control

Features and Benefits


■ Low Crack to Reseat ■ Front and Rear Panel ■ 316L Stainless Steel ■ Orientable Capture Vent
Deviation Mountable Diaphragm Capable
Accurate pressure control Versatile system configuration No inboard diffusion Safety in any installation
■ Brass or 316L Stainless Steel ■ Metal-to-Metal Diaphragm ■ Field-Adjustable Pressure ■ Pressure Range Easily


Barstock Body Seal Limit Changed
Smooth surface finish No possibility of gas Safeguard downstream Maximum flexibility

www.praxair.com/specialtygases
contamination equipment
■ Low Wetted Surface Area
Minimal purge requirements

Specifications Materials
■ Maximum Inlet Pressure ■ Helium Leak Integrity ■ Body ■ Bonnet
250 psig (17 bar) 1 x 10-9 scc/sec 470 Series: 470 Series:
■ Temperature Range ■ Cv Brass barstock Brass barstock
-40 oF to 140 oF 0.1 480 Series: 480 Series:
(-40 oC to 60 oC) 316L Stainless steel barstock Chrome-Plated brass barstock
■ Weight
■ Ports 2.25 lb (1.0 kg) ■ Diaphragm ■ Seat
1/4" FPT 316L Stainless steel Viton ®

Ordering Information – Series CON470ABCD-CGA (Brass)


Series CON480ABCD-CGA (316L Stainless Steel)
A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig None 0: None 0: 1/4" FPT Port 1: Standard Assembly 000: 1/4" FPT
2: 0-50 psig 1: 1/4" Tube Fitting (psig/kPa Gauges) TF2: 1/8" Tube
3: 0-100 psig 2: 1/8" Tube Fitting TF4: 1/4" Tube
4: 0-250 psig 3: 3/8" Tube Fitting

Option Part Number Description


Panel Mount Kit CON5500002 To mount the regulator using bonnet threads. Material: Nickel-plated brass
Captured Vent Kit CON5500001 Orientable 360o for easy piping of vented gases to a safe location in the
event of diaphragm failure. Material: Nickel-plated brass.
Helium Leak Certification CON4760002 Inboard helium leak certification to less than 1 x 10-8 scc/sec

F
29
GAS HANDLING EQUIPMENT
483 and 485 REGULATORS
Critical Purity High Flow Regulators for Non-Corrosive Service

Single Stage Regulator, Brass Barstock Body,


316L Stainless Steel Diaphragm
■ Four-Port Configuration (483 Series Line Regulator)

■ Six-Port Configuration (485 Series Single Stage Regulator)

The 483 (Line) and 485 (Single Stage) Series regulators can be
used in many different applications including high flow purging,
semiconductor manufacturing, manifolds and line regulation.

Typical Applications
■ High flow applications ■ Zero, span, and
■ Bulk gas delivery systems calibration gases
■ Gas and liquid ■ High purity chamber
chromatography pressurization
www.praxair.com/specialtygases

■ High purity carrier gases ■ Liquefied hydrocarbon


gas control 485 Series Regulator

Features and Benefits


■ Brass Barstock Body ■ Pressure Ranges 0-15 to ■ PTFE Teflon® Diaphragm Seal ■ Low Wetted Surface Area
Smooth surface finish 0-200 psig No possibility of gas Minimal purge requirements
■ Rear Panel Mountable Broad range of applications contamination ■ Field-Adjustable Pressure Limit
Versatile system ■ 3000 psig Inlet Pressure Rating ■ 316L Stainless Steel Diaphragm Safeguard downstream
configuration Safe use with high No inboard diffusion equipment
pressure cylinders ■ Balanced Stem Seat
Constant delivery pressure
at high flow

Specifications Materials

■ Maximum Inlet Pressure ■ Helium Leak Integrity ■ Body ■ Filter


3000 psig (210 Bar) 1 x 10-8 scc/sec Brass barstock 40 micron
1-877-PRAXAIR

■ Temperature Range ■ Cv ■ Bonnet 316 stainless steel


-40 oF to 140 oF 1.0 Chrome-plated die cast zinc ■ Diaphragm
(-40 oC to 60 oC) ■ Maximum Flow Rate ■ Seat 316L stainless steel
■ Gauges 8000 scfh (3770 Lpm) KEL-F® ■ Internal Seals
2" diameter brass ■ Weight PTFE Teflon®
■ Ports 4.4 lb (2.0 kg)
1/2" FPT (inlet/outlet)
1/4" FPT (gauges)

Ordering Information – Series CON483ABCD-CGA (Line Regulator)


Series CON485ABCD-CGA (Single Stage Regulator)
A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge* Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 0-30 psig 0: None 0: 1/2" FPT Port 0: Bare Body 483 Series:
2: 0-40 psig 0-60 psig 3: 0-4000 psig 1: 1/2" Tube Fitting 1: Standard Assembly 000: 1/2" FPT
3: 0-120 psig 0-200 psig 5: 0-1000 psig (psig/kPa Gauges) TF8: 1/2" Tube
4: 0-200 psig 0-400 psig 6: 0-400 psig 2: Standard Assembly
5: 0-250 psig 0-400 psig 7: 0-200 psig (bar/psig Gauges) 485 Series:
9: 0-600 psig CGA, DIN 477,
* Not applicable to 483 Series. BS 341 and others available
Always select "0: None"

Option Part Number Description


Helium Leak Certification CON4760002 Inboard Helium leak certification to less than 1 x 10-8 scc/sec
Reversed Inlet/Outlet Configuration Contact Praxair Inlet and outlet ports supplied in a reversed ("mirror image") configuration
F
30
GAS HANDLING EQUIPMENT
484 and 486 REGULATORS
Critical Purity High Flow Regulators for Corrosive Service

Single Stage Regulator, 316L Stainless Steel Barstock Body,


316L Stainless Steel Diaphragm
■ Four-Port Configuration (484 Series Line Regulator)

■ Six-Port Configuration (486 Series Single Stage Regulator)

The 484 (Line) and 486 (Single Stage) Series regulators can be
used in many different applications including high flow purging,
semiconductor manufacturing, manifolds and line regulation.

Typical Applications
■ High flow applications ■ Zero, span, and
■ Bulk gas distribution systems calibration gases
■ Gas and liquid ■ High purity chamber

1-877-PRAXAIR
chromatography pressurization
■ High purity carrier gases ■ Liquefied hydrocarbon
gas control 486 Series Regulator

Features and Benefits


■ Stainless Steel Barstock Body ■ 3000 psig Inlet Pressure ■ 316L Stainless Steel ■ Field-Adjustable Pressure
Smooth surface finish Rating Diaphragm Limit


■ Rear Panel Mountable Safe use with high No inboard diffusion Safeguard downstream
Versatile system pressure cylinders ■ Balanced Stem Seat equipment

www.praxair.com/specialtygases
configuration ■ PTFE Teflon® Diaphragm Constant delivery pressure
■ Pressure Ranges 0-15 to Seal at high flow
0-200 psig No possibility of gas ■ Low Wetted Surface Area
Broad range of applications contamination Minimal purge requirements

Specifications Materials
■ Maximum Inlet Pressure ■ Helium Leak Integrity ■ Body ■ Filter
3000 psig (210 Bar) 1 x 10-8 scc/sec 316L stainless steel 40 micron
■ Temperature Range ■ Cv barstock 316 stainless steel
-40 oF to 140 oF 1.0 ■ Bonnet ■ Diaphragm
(-40 oC to 60 oC) ■ Maximum Flow Rate Chrome-plated die cast zinc 316L stainless steel
■ Gauges 8000 scfh (3770 Lpm) ■ Seat ■ Internal Seals
2" diameter stainless steel ■ Weight KEL-F® PTFE Teflon®
■ Ports 4.4 lb (2.0 kg)
1/2" FPT (inlet/outlet)
1/4" FPT (gauges)

Ordering Information – Series CON484ABCD-CGA (Line Regulator)


Series CON486ABCD-CGA (Single Stage Regulator)
A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge* Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 0-30 psig 0: None 0: 1/2" FPT Port 0: Bare Body 484 Series:
2: 0-40 psig 0-60 psig 3: 0-4000 psig 1: 1/2" Tube Fitting 1: Standard Assembly 000: 1/2" FPT
3: 0-120 psig 0-200 psig 5: 0-1000 psig (psig/kPa Gauges) TF8: 1/2" Tube
4: 0-200 psig 0-400 psig 6: 0-400 psig 2: Standard Assembly
5: 0-250 psig 0-400 psig 7: 0-200 psig (bar/psig Gauges) 486 Series:
9: 0-600 psig CGA, DIN 477
BS 341and others available
* Not applicable to 484 Series. Always select "0=None"

Option Part Number Description


Helium Leak Certification CON4760002 Inboard helium leak certification to less than 1 x 10-8 scc/sec
Reversed Inlet/Outlet Configuration Contact Praxair Inlet and outlet ports supplied in a reversed ("mirror image") configuration F
31
GAS HANDLING EQUIPMENT
492 and 493 REGULATORS
High Inlet/Outlet Pressure for Corrosive or Non-Corrosive Gases

Piston-Sensed Single Stage Regulator For


Ultra High Pressure Service
■ Chrome-Plated Brass Body (492 Series)

■ 316L Stainless Steel Body (493 Series)

The 492 (Chrome-Plated Brass) and 493 (316L Stainless Steel) Series
regulators are intended for primary pressure control of non-corrosive
gases at a maximum inlet pressure of 6000 psig.

Typical Applications
■ Airplane strut charging ■ Aerospace hydraulic systems
■ Research and development ■ Pharmaceutical manufacturing
laboratories ■ Gauge calibration
■ Chemical manufacturing
www.praxair.com/specialtygases

Features and Benefits


■ Large Piston Sensors ■ Front and Rear Panel ■ Capsule® Seat ■ Low Wetted Surface Area
Safely controls pressure Mountable Increased serviceability Minimal purge requirements
to 6000 psig Versatile system configuration and life ■ Field-Adjustable
■ Barstock body ■ Pressure Ranges 0-750 ■ Six Port Design Pressure Limit
Smooth surface finish to 0-6000 psig Flexible installation Safeguard downstream
Broad range of applications alternatives equipment

Specifications Materials
■ Maximum Inlet Pressure ■ Gauges ■ Body ■ Seat
6000 psig (420 bar) 2-1/2" diameter chrome-plated Chrome-plated brass or Arlon® (Peek)
■ Temperature Range brass or 316 stainless steel 316L stainless steel barstock ■ Filter
-40 oF to 140 oF ■ Cv ■ Bonnet 10 micron sintered brass

(-40 oC to 60 oC) 0.1 Chrome-plated brass or ■ Internal Seals


■ Ports ■ Weight 304 stainless steel barstock Viton ®
1-877-PRAXAIR

1/4" FPT (gauges) 5.9 lb (2.7 kg)

Ordering Information – Series CON492ABCD-CGA (Chrome-Plated Brass)


Series CON493ABCD-CGA (316L Stainless Steel)
A B C D CGA
Outlet Pressure Outlet Gauge Inlet Pressure Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet
1: 0-750 psig 0-1000 psig 0: 6000 psig (maximum) None 0: 1/4" FPT Port 0: Bare Body CGA,
2: 0-1500 psig 0-4000 psig 3: 3000 psig (maximum) 0-4000 psig 1: 1/4" MPT 1: Standard Assembly DIN 477,
3: 0-2500 psig 0-4000 psig 8: 5500 psig (maximum) 0-6000 psig 2: 1/4" Tube Fitting (psig/kPA Gauges) BS 341
4: 0-4500 psig* 0-6000 psig 9: 6000 psig (maximum) 0-10,000 psig 5: Needle Valve 1/4" MPT 2: Standard Assembly) and others
5: 0-6000 psig* 0-10,000 psig 6: 1/8" Tube Fitting (psig/kPA Gauges) available
7: 3/8" Tube Fitting
* Not available with 3000 psig maximum inlet pressure

Option Part Number Description


Protocol Station Add Letter “M” after CGA See page F35 for details
Protocol Switchover Station Add Letter “C” after CGA See page F36 for details
Protocol Switchover Station with Alarm Add Letter “G” after CGA See page F36 for details
Protocol Alarm Station Add Letter “A” after CGA See page F37 for details
Deep Purge Add Letter “D” after CGA See page F27 for details

F
32
GAS HANDLING EQUIPMENT
400 and 500 REGULATORS
Special Purpose Regulators for Portable Cylinders

Praxair 400 Series Preset Flow Regulators


The 400 Series regulators are for use with Praxair’s 17 and 34 liter non-refillable cylinders using a
CGA 600 valve. These single stage, piston style regulators are designed for non-corrosive service.
The control valve permits constant gas flow and easy on/off capability. Each regulator comes with
a cylinder pressure gauge and is available in five preset flow ranges.

Specifications Materials Design and Construction


Features
■ Maximum Inlet Pressure ■ Body
500 psig Brass barstock ■ Piston Type Construction
■ Temperature Operating Range ■ Spring Housing Cap ■ Preset Flow Ratings
0 OF to 140 OF Chrome-plated brass ■ On/Off Valve
(-18 OC to 60 OC) ■ Seat ■ 1-1/2" x 700 psig Gauge
■ Outlet Flow Settings (Orifice) Teflon®

1-877-PRAXAIR
0.25, 0.3, 0.5, 1.0, and 1.5 Lpm ■ Piston
■ Inlet Fitting Brass
CGA 600 ■ Piston “O” Rings
■ Outlet Fitting BUNA-N ®
3/16" Hose barb

Ordering Information – 400 Series


Part Number Flow Rate Part Number Flow Rate Part Number Flow Rate


NLB413 0.25 Lpm Air NLB417 0.5 Lpm Air NLB411 1.5 Lpm Air

www.praxair.com/specialtygases
NLB414 0.3 Lpm Air NLB418 1.0 Lpm Air

Praxair 500 Series Preset Flow Regulators


The 500 Series regulators are for use with Praxair’s 58 and 103 liter non-refillable cylinders.
These single stage, piston style regulators are designed for non-corrosive gas service and
have proven to be satisfactory for use with low level corrosive gases (less than 100 ppm)*.
The control valve permits constant gas flow and easy on/off capability. Each regulator comes
with a cylinder pressure gauge and is available in seven preset flow ranges. This series of
regulators is for use with non-refillable cylinders using a 5/8" - 1/8 UNF C-10 valve.
* Low level corrosive gases slowly react with the “wetted” brass parts of the 500 Series regulators.
In order to minimize loss of calibration accuracy, the regulator must be removed from the cylinder
after each use. Praxair’s 6000 Series regulator (page F34) is recommended for extended use with
corrosive gas calibration standards.

Specifications Materials Design and Construction


Features
■ Maximum Inlet Pressure ■ Body
1000 psig Brass barstock ■ Piston Type Construction
■ Temperature Operating Range ■ Spring Housing Cap ■ Preset Flow Ratings
0 OF to 140 OF Chrome-plated brass ■ On/Off Valve
(-18 OC to 60 OC) ■ Seat ■ 1-1/2" x 1200 psig Gauge
■ Outlet Flow Settings (Orifice) Teflon®
0.25, 0.3, 0.5, 1.0, 1.5, ■ Piston
2.5, and 6.0 Lpm Brass
■ Inlet Fitting ■ Piston “O” Rings
5/8" - 18 unf (C-10) BUNA-N ®
■ Outlet Fitting
3/16" Hose barb

Ordering Information – 500 Series


Part Number Flow Rate Part Number Flow Rate Part Number Flow Rate
NLB514 0.25 Lpm Air NLB518 1.0 Lpm Air NLB512 2.5 Lpm Air
NLB516 0.3 Lpm Air NLB511 1.5 Lpm Air NLB515 6.0 Lpm Air F
NLB517 0.5 Lpm Air 33
GAS HANDLING EQUIPMENT
6000 and 8000 REGULATORS
Special Purpose Regulators for Portable Cylinders

6000 Series Multiflow Regulators


The 6000 Series regulators are for use with Praxair’s 58, 103 and 221 liter non-refillable cylinders and can be
configured for use with high pressure refillable cylinders. These aluminum single stage piston style regulators
are recommended for applications requiring a fixed rate. Their aluminum construction is compatible with a wide
range of pure gases and mixtures, including hydrogen sulfide, nitric oxide and sulfur dioxide. The regulator has
eight flow settings ranging from 0.2 to 6 liters per minute. It is available with either a stainless steel or brass
gauge and your choice of CGA connections. Gauges are 1,000 psig for non-refillable cylinders or 3,000 psig
for high pressure refillable cylinders.

Specifications Materials Design and Construction


■ Maximum Inlet Pressure ■ Body Features
2000 psig Aluminum ■ Piston Type Construction
■ Temperature Operating Range ■ Spring Housing Cap ■ Preset Flow Ratings
o o
0 F to 140 F Aluminum ■ 1-1/2" x 1000 or
(-18 oC to 60 oC) ■ Nozzle 3000 psig Gauge
www.praxair.com/specialtygases

■ Outlet Flow Settings (Orifice) Aluminum


0.2, 0.3, 0.5, 1.0, 1.5, ■ Seat
2.5, 5.0 and 6.0 Lpm KEL-F®
■ Inlet Fitting ■ Inboard Filter
5/8" - 18 unf (C-10) 50 micron sintered
or specified CGA stainless steel
■ Outlet Fitting ■ Pressure Adjusting Spring
3/16" Hose Barb Heat-treated mild
steel wire

Ordering Information – 6000 Series


Part Number Description Part Number Description
NLB6C10N Regulator for 103 liter cylinder, brass gauge, 1000 psig NLB6590 Regulator with CGA 590 inlet, 3000 psig
NLB6C10R Regulator for 58 liter cylinder, SS gauge, 1000 psig NLB6330 Regulator with CGA 330 inlet, 3000 psig
NLB6165 Regulator with CGA 165 inlet, 1000 psig

8000 Series Pressure Demand Regulators


The 8000 Series pressure demand regulators are for use with Praxair’s 58 and 103 liter non-refillable
1-877-PRAXAIR

cylinders and can be configured for use with refillable cylinders. This regulator is designed to automatically
provide the correct flow of gas to instruments that have internal pumps for introducing calibration gas into
the instrument. Typical activation suction is from 0 to 3 inches of water, which conveniently matches the
requirements for the many different portable gas monitors on the market. The 8000 Series can be config-
ured for cylinders with supply pressures of 500 psig to 1000 psig. The body of the regulator is nickel plated
brass, has an aluminum bonnet and features viton as the seating material for reactive gases. The aluminum
and nickel plated brass are compatible with a wide range of pure gases and mixtures, including hydrogen
sulfide, nitric oxide and sulfur dioxide. This regulator features an outlet fitting which is a 3/16" hose barb.
The 8660 Series pressure demand regulator is for use with the CGA 660 outlet connection and high
pressure refillable cylinders. It features a gauge available in stainless steel for reactives or brass for
non-reactives, with a pressure range of 0 to 3000 psig.

Specifications Materials Design and Construction


■ Maximum Inlet Pressure ■ Outlet Fitting ■ Body: Nickel Plated Brass
Features
2000 psig 3/16" Hose barb ■ Bonnet: Aluminum ■ Flow Dependent
■ Temperature Operating ■ Outlet Flow Settings ■ Seat and Seals on Instrument Demand
Range Variable, matches instrument Viton® and Teflon® ■ Variable flow ratings
0 OF to 140 OF requirement ■ Gauges ■ 1000 psig or 3000 psig
(-18 OC to 60 OC) Flow range, .25 to 3 Lpm 0-1000 psig for C-10 fittings
■ Inlet Fittings ■ Gauges
5/8" - 18 UNF (C-10) or 0-3000 psig for CGA 330
CGA 330 or CGA 660 and CGA 660

Ordering Information – 8000 Series


Part Number Description Part Number Description
NLB8C10N Regulator for 103 liter cylinder, brass gauge, 1000 psig NLB8590 Regulator with CGA 590 inlet, 3000 psig
NLB8C10R Regulator for 58 liter cylinder, SS gauge, 1000 psig NLB8330 Regulator with CGA 330 inlet, 3000 psig
F NLB8580 Regulator with CGA 580 inlet, 3000 psig NLB8660 Regulator with CGA 660 inlet, 3000 psig
34
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Protocol Station

Protocol Station
The 529 Series Protocol Station is a regulator option designed for
the convenient wall mounting of any Praxair regulator. Wall mounting
of a regulator provides ease of use, prevents regulator damage and
improves safety. The 529 Series Protocol Station is available in brass
or 316 stainless steel construction as specified by the regulator
series. This option comes complete with a 3 foot long flexible all
stainless steel pigtail with armor casing. The CGA connection on the
pigtail has an integral check valve in the gland to prevent internal
contamination during cylinder changeout. Should purging be desired,
the gas block comes with a plugged port which can be removed
and replaced with a diaphragm valve.

1-877-PRAXAIR
Features and Benefits
■ Plugged Port in Gas Block ■ Bracket Mounts
Facilitates purging Attaches conveniently to
■ Integral Check Valve any surface
No internal contamination
during cylinder changeout


Specifications Materials
Maximum Inlet Pressure Weight (For Single Stage Gas Block Inlet Connection

www.praxair.com/specialtygases
■ ■ ■ ■
3000 psig (210 bar) Regulator) 316 stainless steel or 316 stainless steel or
■ Temperature Range* 3.1 lb (1.4 kg) less regulator brass barstock brass barstock
40 oF to 140 oF ■ Weight (For Dual Stage ■ Pigtail ■ Check Valve O-Ring
(-40 oC to 60 oC) Regulator) 316 stainless steel inner core Viton ®
3.5 lb (1.6 kg) less regulator 316 stainless steel braid
(2 layers)
304 stainless steel
armor casing

Ordering Information – Series CON529


Part Number Description
CON5290101-CGA Protocol Station for single stage brass regulators (402/405/109 Series regulators)
CON5290102-CGA Protocol Station for single stage chrome-plated brass regulators (302/304/202/205/206 Series regulators)
CON5290103-CGA Protocol Station for single stage 316L stainless steel regulators (422/425/322/324 Series regulators)
CON5290104-CGA Protocol Station for dual stage brass regulators (412/109 Series regulators)
CON5290105-CGA Protocol Station for dual stage chrome-plated brass regulators (312/212 Series regulators)
CON5290106-CGA Protocol Station for dual stage 316L stainless steel regulators (432/332 Series regulators)
CON5290121-CGA Protocol Station for single stage brass regulators with 4500 psig maximum inlet pressure
CON5290122-CGA Protocol Station for single stage chrome-plated brass regulators with 4500 psig maximum inlet pressure
CON5290123-CGA Protocol Station for single stage 316L stainless steel regulators with 4500 psig maximum inlet pressure
CON5290124-CGA Protocol Station for dual stage brass regulators with 4500 psig maximum inlet pressure
CON5290125-CGA Protocol Station for dual stage chrome-plated brass regulators with 4500 psig maximum inlet pressure
CON5290126-CGA Protocol Station for dual stage 316L stainless steel regulators with 4500 psig maximum inlet pressure
CON5290133-CGA Protocol Station for single stage regulators with 6000 psig maximum inlet pressure
CON5290029-CGA Pigtail, 316L stainless steel 1/4" MPT x 316 stainless steel CGA, 36" long
CON5290031-CGA Pigtail, 316L stainless steel 1/4" MPT x brass CGA, 36" long

Option Part Number Description


Protocol Station Add letter "M" after regulator For example, to order a CON4221331-580 regulator with a Protocol Station
with Regulator part number wall mount, the part number would be CON4221331-580M
F
35
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Protocol Switchover Station

Protocol Switchover Station


The 529 Series Protocol Switchover Station combines all of the
safety and convenience features of a standard Protocol Station with
the added efficiency of having a reserve cylinder connected to the Shown with optional
system. The Protocol Switchover Station valving allows manual Praxair regulator
switching between a primary cylinder and reserve cylinder. Isolation
of the depleted cylinder allows safe changeout without back flow
of gas through the pigtail.
Protocol Switchover Stations are available in brass or 316 stainless
steel with a variety of pressure ranges (3,000 psig, 4,500 psig and
6,000 psig). The system comes complete with a Protocol Station,
two 3-foot all stainless steel pigtails with amour casing, two valves –
diaphragm (3,000 psig) or needle (4,500 or 6,000 psig). Alarms are
also available for the Protocol Switchover Station.
www.praxair.com/specialtygases

Features and Benefits


■ Plugged Port in Gas Block ■ Remote Alarm (Optional) ■ Mountable to Any Surface ■ Low Wetted Surface Area
Facilitates purging Provides audible and Easy installation Minimal purge requirements
■ Pressure Switch Gauge visual warning of cylinder ■ Gas Block ■ 316L Stainless Steel Diaphragm
Provides visual warning depletion Maintain gas purity No inboard diffusion
of cylinder depletion ■ Integral Check Valve ■ Metal-to-Metal Diaphragm Seal
No internal contamination No possibility of gas
during cylinder changeout contamination

Specifications Materials
■ Maximum Inlet Pressure ■ Weight (For Single Stage ■ Gas Block ■ Inlet Connection
3000 psig (210 bar) Regulator) Brass or 316L stainless steel Brass or 316L stainless steel
4500 psig (300 bar) optional 3.1 lb (1.4 kg) less regulator barstock barstock
6000 psig (380 bar) optional

■ Weight (For Dual Stage ■ Check Valve O-Ring ■ Flexible Pigtails


■ Temperature Range Regulator) Viton® 316 stainless steel barstock
1-877-PRAXAIR

-40 oF to 140 oF 3.5 lb (1.6 kg) less regulator ■ Bracket (Innercore – Monel® for
(-40 oC to 60 oC) 304 Stainless Steel oxygen service)

Ordering Information – Series CON529


Part Number Description
CON5290151-CGA Protocol Switchover for brass regulators maximum inlet 400 psig (600 psig gauge)
CON5290152-CGA Protocol Switchover for chrome-plated brass regulators maximum inlet 400 psig (600 psig gauge)
CON5290153-CGA Protocol Switchover for 316L stainless steel regulators maximum inlet 400 psig (600 psig gauge)
CON5290154-CGA Protocol Switchover for brass regulators maximum inlet 3,000 psig (4,000 psig)
CON5290155-CGA Protocol Switchover for chrome-plated brass regulators maximum inlet 3,000 psig (4,000 psig)
CON5290156-CGA Protocol Switchover for 316L stainless steel regulators maximum inlet 3,000 psig (4,000 psig)
CON5290157-CGA Protocol Switchover for brass regulators maximum inlet 4,500 psig (6,000 psig)
CON5290158-CGA Protocol Switchover for chrome-plated brass regulators maximum inlet 4,500 psig (6,000 psig)
CON5290159-CGA Protocol Switchover for 316L stainless steel regulators maximum inlet 4,500 psig (6,000 psig)
CON5290160-CGA Protocol Switchover for 316L stainless steel regulators maximum inlet 6,000 psig (10,000 psig)

Option Part Number Description


Protocol Switchover Station Add letter "C" after regulator For example, to order a CON4221331-580 regulator with
with Regulator part number a Protocol Switchover Station, the part number would be
CON4221331-580C.
Protocol Switchover Station Add letter "G" after regulator For example, to order a CON4221331-580 regulator with
with Alarm and Regulator part number would be a Protocol Switchover Station with alarm, the part number
CON4221331-580G.

F
36
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Protocal Alarm Station

Protocol Alarm Station


The 529 Series Protocol Alarm Station combines all of the safety
and features of a standard Protocol Station with the added security
of a remote alarm system. The Protocol Alarm Station will provide
an audio/visual warning when a cylinder is nearly depleted. The Shown with optional
alarm set point is easily field adjustable to provide the level of Praxair regulator
security and notification required. A convenient side port allows the
addition of a diaphragm valve for purging when changing cylinders.
The Protocol Alarm Station systems are available in brass or
316 stainless steel with a variety of gauge ranges (600 psig,
4,000 psig, 6,000 psig, and 10,000 psig). The system comes
complete with a Protocol Station, a 3-foot all stainless steel pigtail
with armor casing, pressure switch gauge and remote alarm/
power supply in either 110 vac or 220 vac. It may be ordered

1-877-PRAXAIR
separately or attached to any high purity regulator.

Features and Benefits


■ Plugged Port in Gas Block ■ Remote Alarm ■ Mountable to Any Surface ■ Low Wetted Surface Area
Facilitates purging Provides audible and Easy installation Minimal purge requirements
■ Pressure Switch Gauge visual warning of cylinder ■ Gas Block ■ 316L Stainless Steel Diaphragm
Provides visual warning depletion Maintain gas purity No inboard diffusion


of cylinder depletion ■ Integral Check Valve ■ Metal-to-Metal Diaphragm Seal
No internal contaminiation No possibility of

www.praxair.com/specialtygases
during cylinder changeout gas contamination

Specifications Materials
■ Maximum Inlet Pressure ■ Weight (For Single Stage ■ Gas Block ■ Inlet Connection
3000 psig (210 bar) Regulator) Brass or 316L stainless steel Brass or 316L stainless steel
4500 psig (300 bar) optional 3.1 lb (1.4 kg) less regulator barstock barstock
6000 psig (380 bar) optional ■ Weight (For Dual Stage ■ Check Valve O-Ring ■ Flexible Pigtails
■ Temperature Range Regulator) Viton® 316 stainless steel barstock
o o
-40 F to 140 F 3.5 lb (1.6 kg) less regulator ■ Bracket (Innercore- Monel® for
(-40 oC to 60 oC) 304 stainless steel oxygen service)

Ordering Information – Series CON529


Part Number Description
CON5291095-CGA Protocol Alarm for brass regulators maximum inlet 400 psig (600 psig gauge)
CON5291096-CGA Protocol Alarm for chrome-plated brass regulators maximum inlet 400 psig (600 psig gauge)
CON5291097-CGA Protocol Alarm for 316L stainless steel regulators maximum inlet 400 psig (600 psig gauge)
CON5291101-CGA Protocol Alarm for brass regulators maximum inlet 3,000 psig (4,000 psig)
CON5291102-CGA Protocol Alarm for chrome-plated brass regulators maximum inlet 3,000 psig (4,000 psig)
CON5291103-CGA Protocol Alarm for 316L stainless steel regulators maximum inlet 3,000 psig (4,000 psig)
CON5291121-CGA Protocol Alarm for brass regulators maximum inlet 4,500 psig (6,000 psig)
CON5291122-CGA Protocol Alarm for chrome-plated brass regulators maximum inlet 4,500 psig (6,000 psig)
CON5291123-CGA Protocol Alarm for 316L stainless steel regulators maximum inlet 4,500 psig (6,000 psig)
CON5291133-CGA Protocol Alarm for 316L stainless steel regulators maximum inlet 6,000 psig (10,000 psig)

Option Part Number Description


Protocol Alarm Station with Add Letter “A” after regulator For example, to order a CON4421331-580 regulator with
Regulator part number a Protocol Alarm Station, the part number would be CON4221331-580A

F
37
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Critical Purity Automatic Switchovers for Non-Corrosive and Corrosive Services

Critical Purity Switchover


The 522 (Brass) and 523 (316 Stainless Steel) Series high purity
automatic switchover systems are designed to provide continuous
supply of high purity gases to the laboratory, process or instrument.
The system automatically changes cylinder or bank priority from
primary to reserve with no fluctuation in line pressure to provide a
continuous, uninterrupted supply of gas to the process, laboratory
or instrument. Each system may be ordered with internal pressure
switches and a power supply/remote alarm to provide both local and
remote indication of bank status. Each power supply/remote alarm
will operate up to four systems. For use with flammable gases or in
hazardous locations (class 1, division 1, groups A,B,C, or D) optional
intrinsic safety barriers are available. A second option is a telephone
dialer which will signal when a bank is empty. For handling toxic or
poisonous gases, the 523 Series is available with optional Automatic Switchover shown with Remote Alarm
www.praxair.com/specialtygases

captured venting.

Features and Benefits


■ Integral Line Regulator ■ 400 Series Regulators ■ User Friendly Priority Valve ■ Intrinsic Safety
Stable line pressure Capsule® Seat One knob switches Safe use with
during cylinder changeout ■ Metal-to-Metal Diaphragm Seal cylinder priority flammable gases
No possibility of ■ Check Valves in Inlet Gland
gas contamination Prevents contamination
and back flow

Specifications Materials
■ Maximum Inlet Pressure ■ Inlet Connection ■ Line Regulator ■ Check Valves
3000 psig (210 bar) 1/4" FPT Brass barstock (522 Series) Brass with VITON® seals (522)
■ Temperature Range ■ Outlet Connection 316 SS barstock (523 Series) 316 SS with VITON seals (523)

-40 oF to 140 oF 1/4" Swagelok® ■ Diaphragms ■ Internal Seals


(-40 oC to 60 oC) Helium Leak Integrity 316L stainless steel PTFE
1-877-PRAXAIR


■ Gauges 1 x 10-8 scc/sec ■ Seats ■ Pressure Switch
Brass, bronze and ■ Weight PTFE Brass (522 Series)
stainless steel 40 lb (18 kg) ■ Priority Valve 316 SS (523 Series)
■ Maximum Flow (Nitrogen) ■ Dimensions Brass barstock (522) ■ Tube Fitting
600 scfh (283 lpm) 12"W x 11.5"H x 9"D 316 SS barstock (523) 316 SS Swagelok®
(30.5 x 29 x 23 cm) ■ Tubing ■ Enclosure
316 stainless steel Acrylic Powder-Coated Steel

Ordering Information – Series CON522ABCD-CGA (Brass)


Series CON523ABCD-CGA (316 Stainless Steel)
A B C D CGA
Outlet Pressure Inlet Connections Cylinder/Side Assembly Pigtail
2: 0-50 psig 0: 1/4" FPT for Non-Toxic Gases 0: No Inlet Connection 1: Without Pressure Switches Please Specify
3: 0-100 psig 1: Manifolds for Non-Toxic Gases 1: One Cylinder 2: With Remote Alarm (110 VAC) inlet CGA
5: 0-350 psig (36" flexible pigtails at each station) 2: Two Cylinders 3: With Remote Alarm (220 VAC) connection
7: 0-150 psig 3: Diaphragm Valves for Non-Toxic 3: Three Cylinders 4: Without Remote Alarm* (if applicable)
Gases* (Two 36" flexible pigtails) 4: Four Cylinders 5: With Remote Alarm (110 VAC)
4: Manifolds for Non-Toxic Gases 5: Five Cylinders and Intrinsic Safety Barriers
(24" flexible pigtails at each station) 6: Six Cylinders 6: With Remote Alarm (220 VAC)
5: SS Manifolds for Toxic Gases** 7: Seven Cylinders and Intrinsic Safety Barriers
(36" flexible pigtails at each station) 8: Eight Cylinders 7: Without Remote Alarm With
7: SS Manifolds for Toxic Gases** 9: Nine Cylinders Intrinsic Safety Barriers*
(24" flexible pigtails at each station) * Requires system with alarm
8: Diaphragm Valves for Toxic Gases** Note: All assemblies (except
(Two 36" flexible pigtails) number 1) include pressure
9: Diaphragm Valves for Non-Toxic Gases* switches
(Two 72" flexible pigtails)
F
* One cyldiner/side only
38 ** Includes captured vent
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Critical Purity Automatic Switchovers for Non-Corrosive and Corrosive Services

Critical Purity Switchover


The 526 (Brass) and 527 (316 Stainless Steel) Series high purity
automatic switchover systems are designed to provide continuous
supply of high purity gases to the laboratory, process or instrument. Automatic
Due to pressure differential considerations, a line regulator is re- Switchover
commended downstream of the system. The 526/527 Series may shown with
be ordered with the line regulator installed at the outlet or the line Remote Alarm
regulator may be ordered separately for downstream point of use
installation. Typically the 526/527 Series are used with one cylinder
per side. To connect more than one cylinder per side, please order
manifold headers separately (see page F41). The standard models
come with flexible, all stainless steel (Monel® lined for Oxygen service)
pigtails with armor casing. The CGA connection on each pigtail has
a check valve in the gland to prevent contamination and minimize

1-877-PRAXAIR
purging requirements.

Features and Benefits


■ 400 Series Regulators ■ Metal-to-Metal Diaphragm Seal ■ User Friendly Priority Valve ■ Check Valves in Inlet Gland
Capsule® Seat No possibility of One knob switches Prevents contamination


gas contamination cylinder priority and back flow

www.praxair.com/specialtygases
Specifications Materials
■ Maximum Inlet Pressure ■ Cv ■ Bodies ■ Filter
3000 psig (210 bar) 0.1 Brass barstock (526 Series) 10 micron multilayer,
4500 Psig (300 bar optional) ■ Helium Leak Integrity 316 SS barstock (527 Series) sintered 316L stainless steel
■ Temperature Range 1 x 10-8 scc/sec ■ Diaphragms wire mesh (patented)
-40 oF to 140 oF ■ Weight 316L stainless steel ■ Internal Seals
(-40 oC to 60 oC) 8.25 lb (3.71 kg) ■ Seats PTFE
■ Gauges PTFE
2" Diameter

Ordering Information – Series CON526ABCD-CGA (Brass)


Series CON527ABCD-CGA (316 Stainless Steel)
A B C D CGA Series
Switching Pressure Inlet Connections Line Regulator Assembly/Gauges Pigtail
(Priority Right/Left) 0: 1/4" FPT Ports 0: None 1: Standard Assembly Please Specify
2: 70 psig/50 psig 1: Flexible SS Pigtails (36")* 1: 0-15 psig (psig/kPA Gauges) inlet CGA
3: 100 psig/75 psig 2: Manifold Connectors* 2: 0-50 psig 2: Standard Assembly connection
4: 200 psig/170 psig 3: Flexible SS Pigtails (24")* 3: 0-100 psig (psig/bar Gauges) (if applicable)
5: 500 psig/470 psig 4: Diaphragm Valves with 1/4" FPT Port 4: 0-250 psig 3: Pressure Switches
7: 150 psig/130 psig 5: Diaphragm Valves with Pigtails (36")* 7: 0-150 psig and Remote Alarm
6: Diaphragm Valves with
Manifold Connectors
(See page F41 for headers)
7: Diaphragm valves with Pigtails (24")*
8: Flexible Teflon-lined Pigtails (36")**
(4500 psig maximum inlet pressure)
9: 1/4" FPT Ports
(4500 psig maximum inlet pressure)
* Pigtails for oxygen service have
MONEL inner core
** 4500 psig maxium inlet pressure

F
39
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
High Pressure Automatic Switchover System

High Pressure Automatic Switchovers


The 530 Series switchover is an automatic switchover system
designed to deliver a continuous supply of high pressure (up
to 6000 psig), non-corrosive, non-oxidizing gas at flows up to
4000 scfh. The system comes either with flexible pigtails for
use with one or two cylinders per side, or with 1/4" female
NPT connections. A shut-off valve is standard to isolate the
depleted bank during cylinder changeouts. A line regulator is
also standard to control downstream pressure regardless of
bank priority. An alarm system is available to notify the user
when a bank is depleted.
Note: Not for use in O2, CO 2 or N2 O.
www.praxair.com/specialtygases

Features and Benefits


■ 492 Series Brass ■ User-Friendly ■ Check Valves in ■ Capsule® Seat
Barstock Regulators One knob switches Pigtail Inlet Glands Increased serviceablity
Safely controls pressures cylinder priority Prevents contamination
to 6000 psig ■ Line Regulator and back flow
Stable line pressure
during cylinder changeout

Specifications Materials
■ Not for O2, N2O, or CO2 ■ Gauges ■ Bodies ■ Filters
■ Inlet Pressures Available 2-1/2" diameter chrome- Chrome-plated brass 10 micron multilayer,
3000 psig (207 bar) plated brass (non-pressure barstock sintered 316L stainless steel
4500 psig (310 bar) switch models) ■ Cartridges wire mesh (patented)
2-1/2" diameter stainless steel

6000 psig (414 bar) Brass barstock ■ Internal Seals


(pressure switch models) Viton ®
■ Temperature Range ■ Seats
1-877-PRAXAIR

o
-40 F to 140 F o ■ Outlet Connection ®
Arlon (PEEK) ■ Weight
(-40 oC to 60 oC) 1/4" tube fitting 22.5 lb (10.2 kg)
■ Cv
0.1

Ordering Information – Series CON530ABCD-CGA


A B C D CGA
Delivery Pressure Inlet Pressure Inlet Connection Assembly/Gauges Pigtail
(Inlet Gauges)
1: 1000 psig 1: 3000 psig 0: 1/4" NPT Female Port 2: Standard Assembly Please specify inlet
2: 1500 psig (4000 psig/280 bar) 1: (1) 36" Pigtail/Side (psig/bar Gauges) connection (if applicable)
3: 2500 psig 2: 4500 psig with Valve 3: Standard Assembly
4: 3500 psig (6000 psig/414 bar) 2: (2) 36" Pigtails/Side (psig/bar Gauges) CGA, DIN 477, BS 341
3: 6000 psig with Valves 110V Remote Alarm and others available
(10,000 psig/700 bar) 3: Manifold Connectors 4: Standard Assembly
(maximum inlet pressure (psig/bar Gauges) Not for use in O2, CO2
3000 psig) 220V Remote Alarm or N2O

F
40
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Critical Purity Manifolds

Critical Purity Manifolds Features and Benefits


The modular gas distribution system is a flexible modular manifold
■ Modular Design ■ Brass or Chrome-Plated Brass
designed for centralized distribution of high purity gases regardless Flexible field installation No possibility of gas
of facility constraints. Each station has an integral diaphragm valve contamination
■ Internal Diaphragm Valves
for shut-off and gas purity protection. The modular design facilitates
Leak-tight integrity ■ Metal-to-Metal Joints
expansion as gas requirements increase. Each system comes com- Easy field assembly
plete with a flexible, all stainless steel pigtail with armor casing. The ■ Variable Line Pressure
Line pressure and transportation
CGA connection on each pigtail has a check valve in the gland to
changeable on site ■ Silver-Brazed Modules
prevent contamination and minimize purging requirements. Clean installation
“C” “A”
“B”

“A”
15” (381mm) Manifold Connector Assembly
12” (305 mm)

1-877-PRAXAIR
Standard Starter Block Assembly Starter Block Assembly

6” (152 mm ) Extension End Cap Extension End Cap


Compact

13.5” CGA
(343 mm) Adapter


Automatic Switchover System Regulator System

www.praxair.com/specialtygases
Specifications (Brass Headers) Specifications (Stainless Steel Headers)
■ Maximum Inlet Pressure ■ Header ■ Maximum Inlet Pressure ■ Header
3300 psig (230 bar) Brass 3300 psig (230 bar) 316 stainless steel
■ Temperature Range (0.625 OD x 0.095 Wall) ■ Temperature Range (0.625 OD x 0.095 wall)
-40 oF to 140 oF ■ Diaphragm Valve -40 oF to 140 oF ■ Diaphragm Valve
(-40 oC to 60 oC) Brass barstock (body) (-40 oC to 60 oC) 316 stainless steel (body)
■ Connections KEL-F ® (seat) ■ Connections KEL-F® (seat)
Pigtail inlet: 1/4" FPT 316 stainless steel (stems) Pigtail inlet: 1/4" FPT 316 stainless steel (stems)
Outlet: 1/4" FPT 316 stainless steel Outlet: 1/4" FPT 316 stainless steel
(diaphragms) (diaphragms)

Dimensions
Cylinders per Extension 1 2 3 4 5 6 7 8 9 10
“A” Standard (single or double) 6" 18" 30" 42" 54" 66" 78" 90" 102" 114"
“B” Standard (single or double) 15" 27" 39" 51" 63" 75" 87" 99" 111" 123"
“C” Standard (single or double) 30" 54" 78" 102” 126" 150" 174" 198" 222" 246"
Weight Standard (single) 5.7 lb 11.8 lb 17.9 lb 24.0 lb 31.1 lb 36.2 lb 42.3 lb 48.4 lb 54.5 lb 60.6 lb
Weight Standard (double) 6.6 lb 12.7 lb 18.8 lb 24.9 lb 32.0 lb 37.1 lb 43.2 lb 49.3 lb 55.4 lb 61.5 lb
“A” Compact (single or double) 6" 12" 18" 24" 30" 36" 42" 48" 54" 60"
“B” Compact (single or double) 15" 21" 27" 33" 39" 45" 51" 57" 63" 69"
“C” Compact (single or double) 30" 42" 54" 66" 78" 90" 102" 114" 126" 138"
Weight Compact (single) 5.7 lb 11.2 lb 16.7 lb 22.2 lb 27.7 lb 33.2 lb 38.7 lb 44.2 lb 49.7 lb 55.2 lb
Weight Compact (double) 6.6 lb 12.1 lb 17.6 lb 23.1 lb 28.6 lb 34.1 lb 39.6 lb 45.1 lb 50.6 lb 56.1 lb
“A”, “B”, and “C” refer to the lengths specified on the diagram below

Ordering Information – Series CON52BABCD-CGA (Brass)


Series CON52CABCD-CGA (Chrome-Plated Brass)
Series CON52SABCD-CGA (316 Stainless Steel)
A B C D CGA
Configuration Cylinders/Side Pigtail Style Outlet Inlet Connections
1: Standard Single Row 4: Compact Single Row 0: 10 cylinders 6: 6 cylinders 0: None 1: 1/4" FPT Please specify
(right or left extension) (right or left extension) 1: 1 cylinder 7: 7 cylinders 2: Flexible 316 Stainless Steel, 2: With CGA Adapter inlet CGA
2: Standard Double Row 5: Compact Double Row 2: 2 cylinders 8: 8 cylinders 24", with Check Valve
(two pigtails per station) (two pigtails per station) 3: 3 cylinders 9: 9 cylinders 3: Flexible 316 Stainless Steel,
3: Standard Duplex 6: Compact Duplex 4: 4 cylinders 36", with Check Valve
(right and left extensions) (right and left extensions) 5: 5 cylinders 6: Flexible 316 Stainless Steel, F
72", with Check Valve 41
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Laboratory Gas Cabinets

Laboratory Gas Cabinets


The 7000 Series gas cabinet enclosures are used to store gas cylin-
ders and to mount gas delivery panels for the safe use of hazardous
gases. They provide a low cost method to contain any gas releases
and achieve compliance of municipal and customer safety codes.

Features and Benefits


■ Safe storage of compressed gases.
■ Gas releases are contained and vented to an
exhaust system away from workers.
■ Gas leak detection systems can be linked to an alarm
and/or emergency shutoff.
■ Safe use, dispensing and handling of hazardous gases.
www.praxair.com/specialtygases

■ Clean appearance since cylinders are kept inside


enclosure and not in the workplace.

Design and Construction Features


■ Doors and windows that close and latch automatically;
exhaust vent located on top of cabinet
■ Air inlet louvers
■ Internal UL approval fire sprinkler with protective coating
■ Adjustable cylinder brackets

Specifications
■ All welded construction using 11 GA steel.
■ Epoxy coated for maximum protection.

■ 1/4" thick, wire reinforced safety glass window.


1-877-PRAXAIR

Ordering Information
Part Capacity Height Width Depth
Number in (cm) in (cm) in (cm)
SAE7100 1 cylinder 72 (183) 18 (46) 18 (46)
SAE7200 2 cylinder 72 (183) 24 (61) 18 (46)
SAE7300 3 cylinder 72 (183) 36 (91) 18 (46)
SAE7400 4 cylinder 72 (183) 48 (122) 18 (46)

Option Description
Cylinder shelf SAE7001
Cylinder bracket SAE7002
Dome roof configurations SAE7003
Keyed door latch SAE7005
Door latch, non-keyed SAE7006
Air intake filter SAE7010
Custom cabinets Contact Praxair
Rubber floor mat SAE7013

Please see page F43


for control panels,
used with Praxair’s
laboratory gas cabinets.

F
42
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Control Panels

Regulator Three Valve Five Valve


Control Panel Control Panel Control Panel

Features and Benefits


■ Brushed Stainless Steel Panel ■ Integral Check Valve in the CGA Connection ■ Metal-to-Metal Diaphragm Seal

1-877-PRAXAIR
■ Wall Mounted to Protect the Regulator No internal contamination No possibility of internal
during cylinder changeout gas contamination
■ Labeled for Gas Service
Durability and gas service differentiation ■ Mountable to Any Surface ■ Low Wetted Surface Area
Easy installation Minimal purge requirements
■ 400 Series, 6 O’clock Entry Regulators
Capsule® seat ■ Purge Capability of the 3- and 5-Valve ■ 316L Stainless Steel Diaphragm
Regulator Stations No inboard diffusion
Maintains gas purity and helps prevent
contact with flammable or toxic gases


Specifications

www.praxair.com/specialtygases
■ Maximum Inlet Pressure ■ Temperature Range ■ Helium Leak Integrity
3000 psig (210 bar) -40 oF to 140 oF (-40 oC to 60 oC) 1 x 10-9 scc/sec
■ Ports
1/4" FPT

Materials
■ Regulator ■ Pigtail Braid ■ Tubing
High purity brass or 316L stainless 304 stainless steel (2 layers) 316/316L stainless steel for all applicat-
steel barstock 400 series regulators ions (stainless steel ferrules used with
■ Pigtail Armor Casing brass fittings) All tubing ends are “faced”
■ Diaphragms 304 stainless steel
316L stainless steel (as would be done for “orbital welding”) to
■ Valves ensure full flow, and to prevent contami-
■ Seats Brass or stainless steel, high purity nation entrapment zones. Cleaned to gas
PTFE Teflon® diaphragm valves (ball valves are not chromatograph grade and oxygen service
■ Pigtail Innercore used because of stem seal leakage, ■ Check Valves
316 stainless steel, Monel when used and large internal areas where impurities Brass or stainless steel
with oxygen can be trapped)
■ Check Valve O-Ring
■ Fittings Viton®
Swagelok®, brass or stainless steel

Ordering Information – Series CON5RSABCDEF (Regulator Control Panel)


A B C D E F
Material Pressure No. of Stages Pigtail CGA Outlet**
B: Brass 1: 15 psi 5: 500 psi 1: 1 Stage (no purge) 1: 36" Specify 0: 1/4" Tube
S: Stainless 2: 50 psi 7: 150 psi 2: 2 Stage (no purge) 2: 72" 1: 1/8" Tube
3: 100 psi 8: 1 Stage (w/purge)* 2: 1/4" FPT
4: 250 psi 9: 2 Stage (w/purge)* 3: 1/4" MPT
* With purge means block and purge valves
** Multi turn diaphragm valve standard

Ordering Information – Series CON5MVABCDEF (MultiValve Control Panels)


A B C D E F
Material Pressure No. of Valves Pigtail CGA Outlet
F
B: Brass 1: 15 psi 4: 250 psi 3: 3 Valves 1: 36" Specify 1: One stage
S: Stainless 2: 50 psi 5: 500 psi 5: 5 Valves 2: 72" 2: Two stage 43
3: 100 psi 7: 150 psi
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Semiconductor Gas Cabinets, Panels and Controllers

Semiconductor Gas Cabinets, Panels and Controllers


Praxair's two-cylinder and three-cylinder gas cabinets are reliable,
easy to use, and are designed with safety as a priority.

Easy to Use
■ Tapered top for improved airflow ■ Self-closing, self-latching windows
■ Self-retracting cylinder ramps for easy and doors
cylinder installment ■ Minimum 140° opening with cabinets
■ Recessed cylinder scales flush with side by side
cabinet deck for easier liquid cylinder ■ Replaceable bulkhead adapter plates for
replacement easy customer feedthrough installation
■ Skylights for improved internal ambient
lighting
www.praxair.com/specialtygases

Safe
■ Air intake filters and diffuser for ■ UL approved fire sprinkler
continuous, positive ventilation ■ UV and IR detection for flammable and
■ Raised, perforated floor and bottom pyrophoric gases
filtered ait intake eliminate dead pockets ■ Passcode protected to prevent
around cylinder base unauthorized use
■ Minimum velocities of 200 standard ■ Integrated to accept eight external
cubic feet/minute (scfm) air flow through fault inputs
the GC402 model (300 scfm through
■ CE approved
GC403) create a 200 linear feet per
minute (fpm) average face velocity at the
window when open to protect against
minor gas release

Cabinet Configurations
1-877-PRAXAIR

■ Wall-mounted process and purge panels ■ Two-cylinder cabinet ■ Three-cylinder cabinet


with no cabinet shell (inert gases) ■ One process/One purge ■ Two process cylinders one purge

■ Two-cylinder cabinet • One UP6 with UP100 controller, cylinder (alongside process cylinders)
■ Two process cylinders connected to one UP2 manual purge panel • Two UP6 automatic process
remote purge source • One WP5M manual process with panels
• Two UP6 automatic process panels; SM8100 controller, UP2 manual • One UP2 manual purge panel
two UP100 controllers (automatic purge panel • Two UP100 controllers
switchover capability) (automatic switchover capability)
• Two WP5M manual process panels ■ Two WP5M manual process panels

with two SM/SW8100 controllers • UP2 manual purge panel

System Options
■ Z-purge for UP100 controller in ■ Exhaust adapter to 6" (15 cm) or ■ Light tower that glows
NEC Class 1, Division 2 rated locations 8 (20 cm) round exhaust vent ■ green when system flows process gas

■ Automatic cylinder switchover ■ Exhaust monitoring ■ red when system shuts down

for continuous gas flow ■ yellow in warning condition


■ Process bulkheads to accommodate
■ blue when system is off line
■ Cylinder shelves available double containment piping
■ Gas management systems ready
■ Double containment annular space
monitoring

Ordering Information
Model Capacity Height Width Depth
PRXGC402 2 Cylinder 74" (188 cm) 25" (63.5 cm) 19.18" (49 cm)

F PRXGC403 3 Cylinder 74" (188 cm) 37.35" (95 cm) 19.18" (49 cm)

44
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Semiconductor Gas Cabinets, Panels and Controllers

Process Panels

UP6 Process Panel UP2 Manual Purge Panel WP5M Manual Process Panel
for Hazardous Gas Service

1-877-PRAXAIR
Reliable Safe Operation
■ Fully automatic switchover capability for ■ Purge bleed through venturi valve ■ Fully swept flow paths
uninterrupted gas flow (corrosive/pyrophoric gases) ■ Optional vent bleed system continues
■ Industry standard components ■ Mirror-finish stainless steel backplate nitrogen flow to vent system during
■ Leak tested and certified to maximize facilitates component inspection power failure
system integrity ■ Two-point fastened pigtails prevent ■ Dead space free to improve purge


transmission of torque to VCR® efficiency and reduce entrapment areas

www.praxair.com/specialtygases
connection ■ All pneumatic valves are closed during
Easy to Use
■ Positive flow of purge gas out of pigtails power loss or pneumatic failure
■ Single plane design for easy while changing cylinders helps prevent
maintenance atmospheric contamination
■ Dedicated controller
■ Easy-access emergency shutoff button

Automatic System Controllers

UP100 ULTRAPURGE™ SM8100 System Monitor SM8100 Auto Switchover


System controller for Praxair gas System monitoring device for Praxair Required to perform auto-switching
cabinets and panels gas cabinets with manual panels with two manual process panels
■ Includes menu-driven software, ■ Initiates gas flow and alerts operator ■ Continuous process gas flow when
password security, brownout protection, with visual and audible alarms for eight gas handling system includes two
user-configurable set points, gas panel fault conditions manual panels
flow schematic and valve actuation ■ Emergency shutoff button for gas ■ Senses low cylinder alarm in active
verification cabinet shutdown cylinder and automatically switches to
■ In manual override, lighted valve icons ■ Integrates with SW8100 auto reserve cylinder
in schematic diagram become push- switchover device ■ Connects to SM8100 system monitors
button switches to operate valves for both gas panels

F
45
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Bulk Gas Delivery Systems

Bulk Gas Delivery Systems


Praxair is revolutionizing flow rates for ammonia as well as many
other specialty gases. Our patented system significantly reduces the
number of cylinder changeouts required by conventional systems –
leading to improvements in uptime, production costs, more consis-
tent purity, and most importantly, safety.
The proprietary Praxair enclosed heating system allows higher flow
rates while maintaining controlled external tonner temperatures. The
system can be skid mounted to facilitate installation and movement
around the facility. It delivers continuous ammonia flows of 600 slpm
with peaks greater than 900 slpm.

Gases
www.praxair.com/specialtygases

■ Ammonia (NH3) ■ Methane (CH4)


■ Chlorine (Cl2) ■ Nitrogen Trifluoride (NF3)
■ Hydrogen Chloride (NH3 ) ■ Silane (SiH4)
■ Nitrous Oxide (N2O)

Reliable, Easy-to-Use and Safe Operation


■ Self contained purge system ■ Bypass valving allows cross-
■ Failsafe air-to-open valves utilization of gas and
components
■ Data acquisition or remote
monitoring PC interface on ■ Train isolation allows service
controller on one train while the other
remains in service
■ Restrictive flow orifices
■ Excess flow switch
■ Redundant supply trains
■ Ventilated enclosures – air
■ Auto switchover based on

intake filters and diffuser for


weight or pressure
continuous, positive ventilation
1-877-PRAXAIR

Designed for High Purity Heating System


■ Components and piping are ■ Springless, packless ■ Infrared temperature monitor- ■ Fully insulated tonner
electropolished 316L Stain- diaphragm valves ing of tonner surface enclosure
less Steel with an internal ■ All welds are high-purity ■ Automatic shutoff with dual ■ Weather resistant enclosure
finish of less than 10 Ra Max orbital welds set points ■ Enclosure designed for easy
■ Low dead space components ■ All manual connections are ■ Safety critical alarms shut tonner changeouts
and tubing branches VCR type off flow
■ Pressure transducers with ■ Leak tight and tested to
low dead space 1 x 10-9 scc/sec He
■ Minimized wetted surface
area of components

Controller
■ Component burn-in prior to ■ Critical alarms close all valves
shipment ■ AC/DC power failure detection
■ Liquid crystal display TFT ■ Twisted wire pair RS-485
touchscreen ■ Optional fiber optic RS-485
■ Full graphical interface ■ Digital I/O optically isolated to
■ Emergency shutoff button prevent solenoid EM field from
on front disrupting microprocessor
■ All valve actuations are verified ■ Menu driven operation

F Ordering Information
46 Contact your local Praxair representative for part number and pricing.
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Praxair’s VersiGas™ Lab System

Praxair’s VersiGas™ Lab Systems


offer today’s chromatographer
great flexibility when designing
gas delivery systems aimed at
meeting specific point of use gas
concerns. As new instruments
are added to meet increasing
demands for the laboratory, gas
piping systems can grow into a
tangle of tubing, line regulators
and traps, making it difficult to
carry on preventative mainte-
nance. Praxair’s VersiGas lab
system eliminates this concern
and makes it much easier to in-

1-877-PRAXAIR
stall gas handling equipment in
the laboratory.


www.praxair.com/specialtygases
Convenience – Praxair’s VersiGas lab systems are shipped in Quality – The VersiGas lab system is designed,
convenient sections, easily added or removed, to accommodate cleaned and built to ensure the highest quality
your specific application. standards possible.
■ Shipped assembled and ■ Sections connected to rails ■ Flexible design to meet ■ Only 316 SS tubing, which
tested, minimizing installation via brass thumbscrews, specific gas needs has been cleaned to gas
time and cost no tools required ■ Engineered to ensure gas chromatograph grade and
■ Ease of use increases ■ Ideal for future expansion, purity and leak integrity oxygen service, is used in all
lab productivity blank sections and custom ■ Constructed with the highest of our modules
■ Customizable length rails available quality material available ■ All tubing ends are “faced”
■ Annunciator section supplied to ensure full flow and to
■ Versatility ■ Each section is assembled
in 3 pieces so the unit can be prevent contaminant
■ Modularity and leak tested before
removed without disturbing shipment, minimizing entrapment zones
■ Rail mounting system easily
wiring conduits installation time and cost
adapted to any environment

Safety – Gas tubing from centralized gas handling rooms Appearance – The VersiGas lab system is packaged in a neat
may be directly connected to the VersiGas lab system panels, and attractive manner creating a uniform appearance throughout
eliminating the need to locate cylinders within the laboratory. the laboratory.
■ Cylinders placed in safe ■ Consolidate cylinder ■ Aesthetically pleasing ■ All panels are fully formed
storage areas inventories ■ All panels are constructed of and seam welded, no
■ Helps to create a safer ■ Helps you meet Local and brushed stainless steel mounting brackets, which
working environment National Fire Codes (NFPA) ■ No paint chipping or staining can break off
■ Reduced cylinder handling to worry about

F
47
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Praxair’s VersiGas™ Lab System

5 GAS IN GAS OUT GAS IN GAS IN GAS OUT GAS IN

GAS TYPE

2 OFF
VALVE 1

VALVE 2
OFF
ON

ON

3 4 6
ON OFF
GAS PRESSURE GAS PRESSURE
VALVE

VALVE VALVE 3 ON
OFF
BYPASS
ON OFF

GAS REGULATOR VALVE GAS REGULATOR

OFF VALVE 4 ON

OFF ON OFF
OFF
VALVE
ON ON
VALVE VALVE

VALVE 5 ON
OXYGEN
TRAP
OFF
GAS PURIFIER
GAS OUT GAS OUT

Air
Compressor 1
Instrument Instrument
www.praxair.com/specialtygases

1 Air Compressor 3 526/527 Series Switchover 5 522/523 Series Switchover 6 VersiGas Panel
(page F78) (page F39) (page F38) (page F47)

2 Membrane N2 (page F76) 4 Protocol Stations


or Air Dryers (page F79) (pages F35-F37)

Applications Features and Benefits


Any point of use high purity gas delivery applications including: ■ All-in-one Pressure Control, ■ Rail Mounting System
Purification and on/off Valve Allows panel to be mounted
■ Gas and liquid ■ Pharmaceutical manufacturing Convenient, high purity to the wall, to a bench or to
chromatography ■ High purity chamber gas delivery system vertical rails hung from the
■ Ultra high purity carrier gases pressurization ■ In Laboratory Point of Use ceiling
■ Zero, span, fuel, and ■ Gas supply for analyzer Control ■ Pressure Tested Individual
Cylinders located safely in Sections

calibration gases valve actuation.


dedicated gas handling areas Provides flexibility when
■ Cryogenic gases
1-877-PRAXAIR

■ Completely Assembled locating point-of-use panels


(vapor phase) in the laboratory
Quick and easy installation

Specifications Materials
■ Sections Dimensions ■ Delivery Pressure Range ■ Panels ■ Fittings
All sections are 18" (45.7 cm) and Gauge Scale Brushed stainless steel Parker A-LOK®, brass or
high, and the panel face 0-15 psig; 0-30 psig; panels, and stainless steel stainless steel
to wall dimension, when 0-60 psig; 0-100 psig, mounting rails ■ Tubing
mounted, is 6" (15.2 cm) deep. 0-160 psig; 0-200 psig ■ Regulators 316/316L stainless steel for
Section width dependent on ■ Gas Specific Purifiers High purity brass or stainless all applications (SS ferrules
the section type: Helium (inert gases, argon); steel barstock bodies, with used with brass fittings)
■ Regulator Section and
hydrogen; nitrogen; air stainless steel diaphragms ■ All tubing ends are “faced”
Annunciator Section, maximum flow, 500 ml/min (as would be done for “orbital
5" W (12.7 cm) ■ Valves
■ Indicating Glass Moisture Traps Brass or stainless steel, high welding”) to ensure full flow,
■ Valve Section, 6.7" W (17 cm)
250 cc purity diaphragm valves (Ball and to prevent contamination
■ Regulator Section with
valves are not used because of entrapment zones.
Purifiers in Series or Parallel, ■ Non-Indicating Traps ■ Cleaned to gas chromatograph
15" W (38.1 cm) Moisture; stem seal leakage, and large
internal areas where impurities grade and oxygen service
■ Regulator Section with One hydrocarbon; oxygen
Purifier, 10" W (25.4 cm) maximum flow, 500 ml/min can be trapped)
■ Purifier Section with Purifiers
■ Indicating Oxygen Trap
in Series, 10" W (25.4 cm) Can be used to show gas
■ Purifier Section with Purifiers
specific purifier break through
in Parallel, 15" W (38.1 cm) when tubed in series
■ Blank sections, as required
for any of the above

F
48
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Praxair’s VersiGas™ Lab System

Praxair’s VersiGas™ Numbering System


Mounting rails and thumb screws are supplied with each section.
When multiple units (modules or sections) are to mount together
as an assembly, specify, so full length rails can be supplied for
the assembly.

A – Regulator Section – 5VR Series


GAS IN GAS OUT

A high purity single stage regulator (either brass or stainless steel)


is supplied with a high purity, 1/4 turn, diaphragm valve and gauge to
give you accurate control of pressure at your point-of-use.

GAS PRESSURE
Ordering Information – Series CON5MVABCD (Regulator Panel)

1-877-PRAXAIR
A B C D
GAS REGULATOR Material Pressure Inlet Connection Outlet Connection
B: Brass 100: 15 psig 0: 1/4" Tube 0: 1/4" Tube
OFF
F S: Stainless 200: 50 psig 1: 1/8" Tube 1: 1/8" Tube
ON
VALVE
300: 100 psig 2: 1/4" FPT 2: 1/4" FPT
45 400: 250 psig
500: 500 psig
700: 150 psig


B – Valve Outlet Section – 5VA Series

www.praxair.com/specialtygases
GAS IN

GAS TYPE
These panels take a single gas inlet from a regulator section or purifier
VALVE 1 ON
section, and give you from one to five separate outlets. Each outlet is
OFF controlled by a high purity, 1/4 turn, diaphragm valve (either brass or
stainless steel).
VALVE 2 ON

OFF

Ordering Information – Series CON5VAABCDE (Valve Panel)


VALVE 3 ON

OFF
A B C D E
Material Pressure No. of Valves Inlet Connection Outlet Connection
VALVE 4 ON

OFF B: Brass 3: 3000 psig max. 30: 3 Valves 0: 1/4"Tube 0: 1/4" Tube
S: Stainless 40: 4 Valves 1: 1/8" Tube 1: 1/8" Tube
VALVE 5 ON
50: 5 Valves 2: 1/4" FPT 2: 1/4" FPT
OFF

GAS OUT

C – Regulator Section with Purifiers/Traps in Series – 5VP Series


GAS IN
We have taken modules “A” and “B” above, and combined them into
a single unit for your convenience.

OFF
Ordering Information – Series CON5VPABCDE (Purifier Panel)
ON
VALVE A B C D E
OFF VALVE
BYPASS Material Trap Type 1 Trap Type 2 Inlet Connection Outlet Connection
ON
VALVE
B0: Brass 0: Purifier 0: Purifier 0: 1/4"Tube 0: 1/4" Tube
OFF
S0: Stainless 1: Hydrocarbon 1: 1/8" Tube 1: 1/8" Tube
ON 2: Moisture 2: 1/4" FPT 2: 1/4" FPT
VALVE

OXYGEN
TRAP
GAS PURIFIER
GAS OUT

F
49
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Praxair’s VersiGas™ Lab System

D – Blank Filler Plates


These are supplied in different widths to accommodate
future expansion.

Blank Sections
CONBLNK 050 5" Wide Section
CONBLNK E50 5" Wide Electrical Section
CONBLNK 067 6.7" Wide Section
CONBLNK 100 10" Wide Section
CONBLNK 150 15" Wide Section
www.praxair.com/specialtygases

E – Annunciator Section
Available in either a four or eight point configuration, this 5" wide
VersiGas section allows for the operator to know the status of their
remote gas supply. When the gas supply system is ordered with
switches, this annunciator will indicate when your gas supply needs
attention. This unit comes with flashing lights, audible horn, first out
indication, an acknowledge button, and a dry contact for remote
annunciation. This annunciator is also available in a wall mounted
fiberglass box for mounting outside the lab area.

Annunciators
CONANN1 4 Point Annunciator in 5" Wide, 3 Piece Electrical Section VersiGas Panel
CONANN2 8 Point Annunciator in 5" Wide, 3 Piece Electrical Section VersiGas Panel

CONBXANN1 4 Point Annunciator in Fiberglass Box (13" H x 10" W x 7.5" D


CONBXANN2 8 Point Annunciator in Fiberglass Box (13" H x 10" W x 7.5" D
1-877-PRAXAIR

F – Rail Sections
The Rail mounting system adapts easily to any environment. Each section is automatically supplied
with fully welded wall mounting rails and brass thumbscrews. Mounting the section to the rail requires
no tools. When sections are supplied to form an assembly, longer rails are supplied to accommodate
the entire system. When future expansion is anticipated, custom length rails can be supplied, allowing
for the sections to be easily moved in approximately 2" increments along the rails. Blank sections can
be ordered to fill future expansion needs.
When custom length rail sections are required, use the configurator, and a pair of rails will be supplied
with brass thumb screws (4 with every five inch increment)
When modules are to be combined into an assembly of several units, please supply the
configuration so rails and inlet/outlet connection locations can be customized to your application.

Follow these examples: Configurator J –


Rail Sections–Two Rail Sections Supplied (Top and Bottom)
Assembly No. 1: E, C, H (150), I
This would be a regulator section CONRAIL XXX Standard Section Lengths:
with purifiers/traps in series, a 050 = 5" Wide
valve outlet section, a 15" blank, 067 = 6.7" Wide
and an annunciator section
100 = 10" Wide
combined to form an assembly.
150 = 15" Wide
Assembly No. 2: A, D, C, I
XXX = XX.X" Special (specify length)
This would be a regulator
section, a purifiers/traps in
F parallel section, a valve outlet
section, and an annunciator
50
section combined to form an
assembly.
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Praxair’s Multi-Gas Point-of-Use Panels

Praxair’s Multi-Gas Point-of-Use Panels GAS INLET

allow from one to five gases to be effectively


pressure-controlled to one or multiple in- REGULATOR #1

GAS OUTLET #1

struments or use points in your laboratory.


OFF

GAS 1 GAS 2 GAS 3 GAS 4 GAS 5 VALVE #1

REGULATOR #2
Vertical
Horizontal Mounted Sections OFF
GAS OUTLET #2
Mounted
VALVE #2

Sections
REGULATOR #3

GAS OUTLET #3

Horizontal Surface Mounted Sections OFF

VALVE #3

REGULATOR #4

GAS OUTLET #4

OFF

VALVE #4

REGULATOR #5

GAS OUTLET #5

GAS 1 GAS 2 GAS 3 GAS 4 GAS 5 OFF

1-877-PRAXAIR
VALVE #5

Features and Benefits


■ Up to five single stage, high-purity brass ■ Horizontally-mounted panels can be ■ Vertically-mounted panels can be
or stainless steel regulators. supplied in two variations: supplied with the outlet connections
■ 1/4 turn high-purity diaphragm valves for ■ Regulators, valves and tubing mounted exiting the right side or the bottom of
each regulator. behind the panel surface (Bonnet- the panel.
■ Two piping configurations — multiple Mounted Regulators) ■ 316 stainless steel tubing, cleaned to


gases inlets and outlets, or a single gas ■ Regulators mounted to the surface of the gas chromatograph grade.

www.praxair.com/specialtygases
inlet with up to five outlets. panel, with valves and gauges attached ■ Fully welded, brushed stainless
■ Horizontal or vertical mounting require a directly to the regulators (Surface- steel panel.
minimal laboratory space. Mounted Regulators).

Materials
■ Panels ■ Regulators ■ Tube Fittings
Fully welded brushed stainless steel High purity brass or stainless steel Brass or stainless steel, stainless steel
■ Mounting Rails 400 Series regulators compression fittings
Stainless steel, with thumbscrews ■ Valves ■ Tubing
for easy mounting Brass or stainless steel, 1/4 turn, 316L stainless steel cleaned to gas chro-
high purity diaphragm valves matograph grade and oxygen service

Specifications
■ Panel Dimensions
Horizontal Sections – Horizontal Sections – Vertical Mounted Sections
Bonnet-Mounted Regulators Surface-Mounted Regulators 5 Regulator Section:
5 Regulator Section: 5 Regulator Section: 36" H x 6" D x 10.5" W (91.5 x 15.2 x 26.7 cm)
10.5" H x 6" D x 36" W (26.7 x 15.2 x 91.5 cm) 10.5" H x 6" D x 22" W (26.7 x 15.2 x 55.9 cm) 4 Regulator Section:
4 Regulator Section: 4 Regulator Section: 29" H x 6" D x 10.5" W (73.7 x 15.2 x 26.7 cm)
10.5" H x 6" D x 29" W (26.7 x 15.2 x 73.7 cm) 10.5" H x 6" D x 22" W (26.7 x 15.2 x 55.9 cm) 3 Regulator Section:
3 Regulator Section: 3 Regulator Section: 22" H x 6" D x 10.5" W (55.9 x 15.2 x 26.7 cm)
10.5" H x 6" D x 22" W (26.7 x 15.2 x 55.9 cm) 10.5" H x 6" D x 15" W (26.7 x 15.2 x 38.1 cm) 2 Regulator Section:
2 Regulator Section: 2 Regulator Section: 15" H x 6" D x 10.5" W (38.1 x 15.2 x 26.7 cm)
10.5" H x 6" D x 15" W (26.7 x 15.2 x 38.1 cm) 10.5" H x 6" D x 15" W (26.7 x 15.2 x 38.1 cm) 1 Regulator Section:
1 Regulator Section: 1 Regulator Section: 8" H x 6" D x 10.5" W (20.3 x 15.2 x 26.7 cm)
10.5" H x 6" D x 8" W (26.7 x 15.2 x 20.3 cm) 10.5" H x 6" D x 8" W (26.7 x 15.2 x 20.3 cm)

Ordering Information – Series CON5MPABCDEFG (Bonnet-Mounted Regulators)


Series CON5MSABCDEFG (Surface-Mounted Regulators)
A B C D E F G
Material Pressure No. of Regulators Type Inlet Outlet Orientation
B: Brass 1: 15 psi 1: 1 Regulator 1: Individual Inlets 0: 1/4" tube 0: 1/4" tube 0: Horizontal
S: Stainless 2: 50 psi 2: 2 Regulators 2: Combined Inlets 1: 1/8" tube 1: 1/8" tube 1: Vertical *
3: 100 psi 3: 3 Regulators 2: 1/4" FPT 2: 1/4" FPT
4: 250 psi 4: 4 Regulators
5: 500 psi 5: 5 Regulators F
7: 150 psi 51
* Not available for Surface-Mounted Regulators
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Praxair’s ULTRASPEC™ 1000 Analyzers

Praxair’s ULTRASPEC™ Series 1000 Argon Purity


Analyzer for Fixed or Portable Applications
Praxair’s ULTRASPEC™ 1000 Series Argon Purity Analyzers offer fixed
or portable, cost-effective analysis in argon for multiple impurities
such as moisture, nitrogen and methane for a wide variety of appli-
cations. The ULTRASPEC 1000, with a measurement range of 10 ppb
to 5 ppm, is ideal for a variety of Quality Control/Quality Assurance
(QC/QA) applications. The ULTRASPEC 1010, with its higher mea- Rack Mounted
surement range of 100 ppb to 50 ppm, is ideal for any application
where greater than 1 ppm impurity is routinely expected.
Praxair’s ULTRASPEC 1000 Series takes advantage of the entire
spectrum of impurity emissions to give you a powerful and adapt-
able means of reliable continuous multiple impurity detection. The
ULTRASPEC 1000 Series is a single solution for comprehensive, Portable
www.praxair.com/specialtygases

fast, and accurate measurement of trace impurities in argon. Each


ULTRASPEC 1000 Series analyzer is factory calibrated and includes
baseline compensation to provide a stable zero over time. Intended
to be a hands-off analyzer, the system is completely automated,
including start-up, purge and operation. An on-board expert system
is incorporated to further enhance system reliability. Panel Mounted

Applications Features
■ In-Line Monitoring Tool ■ Quality Verification of Bulk ■ Analog or RS-232 ■ Available in rack mounted,
■ Purifier Protection Gas Lines in a Fab serial interface wall mounted, or portable
■ Purifier End-Point Detection ■ Bulk Tank Monitor ■ Full internal instrument configuration
■ Cylinder Analysis diagnostics ■ Hands-off operation
■ Factory calibrated: ■ Fast start-up
no field calibration required

Benefits
1-877-PRAXAIR

■ Wide sample pressure ranges ■ Multiple impurities analyzed ■ Fundamental sampling ■ Exceptional stability over time
for a variety of applications over continuous spectrum system virtually eliminates ■ Reliable
long purge-down times

Specifications
■ Impurities in Argon ■ Inlet Pressure ■ Outputs ■ Dimensions
Selectable: nitrogen, (Flow Rate) Options 2 analog analysis outputs: Portable (dimensions
moisture, methane High: 1 - 5 VDC standard without handle):
■ Measurement Range 50-300 psig; 345-2068 kPa (1 -10 VDC optional) 5.9" H X 13.8" W X 10.4" D
ULTRASPEC 1000: (400-1400 ccm; .8-3.0 scfh) 15-pin DB15 female connector (15 cm x 35 cm x 26.3 cm)
10 ppb-5 ppm ■ Power Required 6 digital analyzer status Wall-mount (dimensions
ULTRASPEC 1010: 110 or 240 VAC (user outputs: without mounting brackets):
100ppb-50 ppm configurable), 50-60 Hz 25-pin DB25 male connector 9.8" H x 13.8" W x 3.9" D
■ Serial Communications (25 cm x 35 cm x 10 cm)
■ Inlet Pressure ■ Operating Temperature Range Rack-mount:
(Flow Rate) Options 59 oF to 86 oF (15 oC to 30 oC) RS-232C serial interface
9600 baud 5.2" H x 19" W x 11" D
Low: ■ Display (13.3 cm x 48.3 cm x 28 cm)
5-50 psig; 34.5-345 kPa 9-pin DB9 female connector
2 line x 20 character ■ Weight
(up to 400 ccm; up to .8scfh) vacuum fluorescent display
Standard: Portable: 10.5 lb (4.7 kg)
Seven-system status LED’s Wall-mount: 12.5 lb (5.6 kg)
30-150 psig, 207-1034 kPa located on front panel
(620-2500 ccm, 1.3-5.3 scfh) Rack-mount: 15 lb (6.7 kg)

Ordering Information
Please contact your local Praxair representative

F
52
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Sulfinert™ and Silcosteel™ Treatments

Stainless steel sample cylinders (pressure rated to 1800 psig by the


Department of Transportation) commonly are used in the collection
and analysis of refinery and natural gas samples. These samples
often contain trace amounts of sulfur-containing compounds (e.g.,
hydrogen sulfide, mercaptans, and sulfides), which may interfere
with reactions or damage catalysts in many petrochemical pro-
cesses. Because sulfur compounds are quickly adsorbed by stain-
less steel surfaces, accurate determination of these compounds is
impossible when using untreated sample cylinders.
Restek’s Sulfinert ™ passivation technique bonds an inert layer to the
surface of the stainless steel. Most stainless steel products can be
treated with Sulfinert ™ passivation, including tubing (see Table 1 for
recommended bending radiuses of tubing). Because the Sulfinert™
layer is incorporated into the structure of the stainless steel, treated

1-877-PRAXAIR
surfaces can be bent without affecting the inertness characteristics.
This layer acts as a barrier preventing active compounds from
reacting or adsorbing to the stainless steel. Therefore, Sulfinert ™
products are ideal for the storage and transfer of reactive sulfur-
containing compounds.

Table 1 - Minimum bend radius of Sulfinert™ tubing Table 2 – Sulfur Compounds


Tubing Size (OD) Minimum Allowable Bend Radius Stock Conc. Cylinder Conc.


1/16" 1" Compound Formula (ppmv) (ppbv)

www.praxair.com/specialtygases
1/8" 2" Hydrogen Sulfide H2 S 100 17
1/4" 4" Carbonyl Sulfide COS 100 17
Methyl Mercaptan CH3SH 100 17
Ethyl Mercaptan CH3CH2SH 100 17
A GC analytical method was developed to demonstrate the effects Dimethyl Sulfide* CH3SCH3 100 17
of using Sulfinert™ transfer lines, sample loops, and sample cylinders Dimethyl Disulfide CH3SSCH3 100 17
for the analysis of low-level reactive sulfur compounds. To characterize
* Listed as internal standard
Sulfinert™ surfaces, the stability of sulfur compounds in three Sulfinert™
sample cylinders was tested over a 54-hour period. Table 2 lists the
compounds used in the test and the concentration of the standards.

Analytical System
The analytical system was prepared so that a 17 ppbv standard could 1mL Sulfinert™
be detected with enough sensitivity to quantitate compound loss. sample loop SCD
The sample introduction was designed with a 1mL Sulfinert ™ sample
loop, Sulfinert™ Valco® valve, and 1/16 -inch Sulfinert™ transfer lines
Sulfinert™
(Figure1). The analytical column was connected directly to the
sample
Valco® valve.
cylinder
Figure 1 – In order to control transfer of the sample to the 1 ml
sample loop, an orifice was attached to the exit of the sample loop. Rtx ®-1
This allowed a controlled flow in the range of 60-120 ml/min. during analytical
sample transfer (the flow is pressure-regulated from the sample column
cylinder). An Rtx®-1 column (60 m x 0.53 mm, 7 µm) and a Sievers
model 355 sulfur chemiluminescence detector (SCD) were used. orifice = 0.0060"

1 ml of a 1000 ppb standard was added to a 500 cc sample cylinder exit


and pressurized to 160 psig. The standards were made “dry” (mean-
The analytical system was
ing no water was added to the cylinder) to simulate the petrochemical
designed so that the 17 ppbv
process. Dimethyl sulfide, which has been shown to be non-reactive
standard could be detected
in the standard and is not adsorbed by stainless steel, was used as
with sensitivity to qauntize
an internal standard for the study. To introduce the sample to the GC
compound loss.
column, the sample loop was flushed with sample for 45 seconds.
Then the cylinder valve was closed and the pressure in the sample
loop was vented to atmospheric pressure. Once the sample loop was
at atmospheric pressure, the Valco® valve was switched to introduce
F
the sample from the loop to the analytical column, and the GC ana-
lysis was started. Figure 2 (see page F54) shows the chromatogram 53
of the sulfur standard on the Rtx®-1 column and SCD detection.
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Sulfinert™ and Silcosteel™ Treatments

Analytical System, (continued)

Figure 2 Figure 3
Sulfur standard on an 1
Hydrogen Sulfide Carbonyl Sulfide Methyl Mercaptan
120
Rtx®-1 column with 120 120

recovery (%)
recovery (%)
recovery (%)
SCD detection. 100 100 100

1 Hydrogen sulfide 80 80 80
2 Carbonyl sulfide
3 0 0 0
3 Methyl mercaptan 0 10 20 30 40 50 60 0 10 20 30 40 50 60 0 10 20 30 40 50 60
time (hours) time (hours) time (hours)
4 Ethyl mercaptan
5 Dimethyl sulfide Ethyl Mercaptan Dimethyl Disulfide
120 120
6 Dimethyl disulfide

recovery (%)
recovery (%)
Sulfinert™ cylinder 1
100 100
60m, 0.53mm ID, Sulfinert™ cylinder 2
2 5
7.0um Rtx®-1 6 80 80
Sulfinert™ cylinder 3
(cat.# 10193) 0 0
www.praxair.com/specialtygases

0 10 20 30 40 50 60 0 10 20 30 40 50 60
Oven temperature time (hours) time (hours)

30 oC (hold 1 minute) to
180 oC @ 10 oC/minute 4 Stability of sulfur compounds is remarkable in Sulfinert™ cylinders.
GC ???
(hold 5 minute)
Results
Carrier gas
Helium As shown in Figure 3, the results of the analysis indicate that
Flow rate Sulfinert™ cylinders and accessories are stable for reactive sulfur
8.5 mL/minute compounds over the 54-hour test period. The stability results of
hydrogen sulfide exhibit greater than 85% recovery over the test
minute 5
period. The other compounds (methyl mercaptan, ethyl mercaptan,
carbonyl sulfide, and dimethyl disulfide) all exhibited greater than
90% recovery over the 54-hour test period.

Sulfinert™ Sample Cylinders, Valves and Rupture Discs



1-877-PRAXAIR

Sulfinert™ Sample Cylinders Sulfinert™ Sample Cylinder


Valves
Restek offers a complete line of gas sampling equipment, ideal
for applications such as natural gas sampling and beverage-grade
carbon dioxide testing that require the inertness of Sulfinert ™ coating. Ordering Information
By using Sulfinert™ cylinders, sulfur compounds will be stable during Part Number Description
transport from the field to the laboratory. REK24127 1/4" NPT oulet
REK24128 1/4" compression
Features
oulet
■ Sizes range from 75cc ■ D.O.T. rated to 1800psi at REK21395 1/4" FPT outlet
to 2250cc room temperature (built in rupture disc)
■ 1/4" female NPT threads on ■ Stable storage of samples
both ends containing low-concentration
■ Made from 316 stainless steel sulfurs
Sulfinert™ Rupture Disc Tee

Ordering Information
Ordering Information
Part Number Description
Part Number Description
REK24130 Sulfinert-Treated Sample Cylinder – 75cc
REK21396 Sulfinert™
REK24131 Sulfinert-Treated Sample Cylinder – 150cc Rupture Disc Tee
REK24132 Sulfinert-Treated Sample Cylinder – 300cc REK24298 Replacement
REK24133 Sulfinert-Treated Sample Cylinder – 500cc Rupture Disc
F (not coated)
REK24134 Sulfinert-Treated Sample Cylinder – 1000cc
54
REK21394 Sulfinert-Treated Sample Cylinder – 2250cc
GAS HANDLING EQUIPMENT
GAS DELIVERY SYSTEMS
Silcosteel-Treated Gas Delivery System

Treating parts and components with Restek’s Silcosteel™ metal


passivation process is a proven way to create inert, corrosion-
resistant surfaces. The Silcosteel™ process covers metal surfaces
with inert silica from several angstroms to 5 microns thick. The
Silcosteel metal passivation process utilizes temperatures to
750 oF (400 °C), bonding the silica layer permanently to the metal.

Ordering Information – Series CON432ABCDCGAR (Dual Stage)


Series CON422ABCDCGAR (Single Stage)
A B C D CGA

1-877-PRAXAIR
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assembly Assembly / Gauges Inlet Connection
2: 0 to 50 psig 30"-0-100 psig 3: 0 to 4000 psig 0: 1/4" FPT Port 1: Standard Assembly 350, 330 and 660
3: 0 to 100 psig 30"-0-200 psig 3: Diaphragm Valve (psi/kPa Gauges)
1/4" Tube Fitting
8: Diaphragm Valve
1/8" Tube Fitting

Option Part Number Description


Regulator with Protocol Station Add letter “M” after Part Number See page F35-F37 for details

www.praxair.com/specialtygases
Silcosteel-Treated Welded/Drawn Grade Silcosteel-Treated Fittings
304 Stainless Steel Tubing
Part Number Description
Part Number ID OD REK20510 Union with Two 1/16" Tube Fittings
REK20590 0.011" (0.28 mm) 0.022" (0.56 mm) REK20511 Union with Two 1/8" Tube Fittings
REK20591 0.021" (0.53 mm) 0.029" (0.74 mm) REK20512 Union with Two 1/4" Tube Fittings
REK20592 0.010" (0.25 mm) 1/16" (1.59 mm) REK20513 Tee with Three 1/16" Tube Fittings
REK20593 0.020" (0.51 mm) 1/16" (1.59 mm) REK20514 Tee with Three 1/8" Tube Fittings
REK20594 0.030" (0.76 mm) 1/16" (1.59 mm) REK20515 Tee with Three 1/4" Tube Fittings
REK20595 0.040" (1.02 mm) 1/16" (1.59 mm) REK20516 90o Elbow with Two 1/16" Tube Fittings
REK20596 0.085" (2.16 mm) 1/8" (3.18 mm) REK20517 90o Elbow with Two 1/8" Tube Fittings
REK20597 0.210" (5.33 mm) 1/4" (6.35 mm) REK20518 90o Elbow with Two 1/4" Tube Fittings
REK20519 Reducer with 1/16" x 1/8" Tube Fittings
Silcosteel-Treated Seamless Grade REK20520 Reducer with 1/16" x 1/4" Tube Fittings
316 Stainless Steel Tubing
REK20521 Reducer with 1/8" x 1/4" Tube Fittings
Part Number ID OD REK20522 Union with 1/4" MPT x 1/4" Tube Fittings
REK20598 0.055" (1.40 mm) 1/8" (3.18 mm) REK20523 Union with 1/4" MPT x 1/8" Tube Fittings
REK20599 0.180" (4.57 mm) 1/4" (6.35 mm) REK20524 Union with Two 1/4" MPT Fittings
REK20580 Zero Dead Volume Union with
Silcosteel-Treated Straight Tubing 18" Length Two 1/16" Tube Fittings

Part Number ID OD REK20582 Zero Dead Volume Union with


Two 1/8" Tube Fittings
REK20575 0.085" (2.16 mm) 1/8" (3.18 mm)
REK20581 Zero Dead Volume Tee with
REK20576 (5 Pack) 0.085" (2.16 mm) 1/8" (3.18 mm) Three 1/16" Tube Fittings
REK20577 0.210" (5.33 mm) 1/4" (6.35 mm) REK20583 Zero Dead Volume Tee with
REK20578 (5 Pack) 0.210" (5.33 mm) 1/4" (6.35 mm) Three 1/8" Tube Fittings

F
55
GAS HANDLING EQUIPMENT
FLOW DEVICES
Overview

A variable area flowmeter (Figure 1) is a device used for measuring the 1. Metering Tube Assembly
2. Float
flow of gases or gas mixtures. Typically, it consists of a glass metering 3. Float Stops 8
4. Packing Gaskets & Grommets 9
tube (1) which is internally tapered such that the inside diameter at 5. Seal Spindle & O-Rings
the bottom of the tube is smaller than that at the top. A float or floats 6. End Block (Outlet)
5
7. End Block (Inlet) 6
(2) placed inside the tube are contained by float stops (3) inserted 8. Inlet & Outlet Adaptors 5
9. Adaptor O-Rings
into the inlet and outlet of the tube. The tube assembly is fitted bet- 10. Front Plate 5
ween the two end blocks (6 & 7) and sealed by packing gaskets (4). 11. Back Plate
12. Side Plates
The flowmeter assembly is held together by front, back and side 13. Metering Valve Assembly 4
4
plates (10, 11 & 12). Once assembled, the flowmeter tube is tight- 3
ened against the packing gaskets via a seal spindle (5) to ensure leak 2
free operation. Flowmeters may also be equipped with a metering 12 11

valve (13) which adds the capability of controlling flow rate. 1

As gas enters the flowmeter tube, the float is lifted from the zero
position at the bottom of the tube. The float (Figure 2) rises to a point
3
where the area surrounding the float is sufficient to allow unrestricted
www.praxair.com/specialtygases

4
flow of gas. The greater the flow of gas, the higher the float will rise. 10 4 12
By knowing the variables involved (service gas, pressure, tempera-
ture, weight of float, tube diameter, etc.), the height of the float can 9
8

be directly correlated to the flow of gas with relatively good accuracy.


Generally, the tube is inscribed with a scale allowing the user to read 7
the float position. The scale may be direct reading in flow units such Figure 1 –
as standard liters per minute (slpm) or standard cubic feet per hour 13 Variable Area Flowmeter
(scfh). It may also be in a linear measurement such as millimeters
(mm) which would require a calibration chart for cross referencing In selecting a flowmeter, the following items should be taken
the linear measurement to a corresponding flowrate. into consideration:
The accuracy of a variable area flowmeter is contingent on both its 1. Materials Compatibility: As with all gas handling equipment, care
operating pressure and temperature. Gases at higher pressures must be taken to ensure that the materials used to construct the flow-
will be compressed, and therefore a greater volume of gas will pass meter are compatible with the service gas. Each of the flowmeters
through the same given area. Similarly, gases at higher temperatures shown in this catalog is provided with a list of its materials of construction.
will be less dense, and less gas will pass through a given area. There-
2. Pressure and Temperature Ratings: The flowmeter must be

fore, all variable area flowmeters are calibrated at specific tempera-


capable of handling pressures and temperatures required by the
ture and pressure conditions – generally at normal temperature (70 oF)
1-877-PRAXAIR

particular application. Maximum operating pressures and tempera-


and pressure (14.7 psia).
tures are provided for each flowmeter under “Specifications.”

Front View Top View 3. Measuring Range: Flowmeters have specific measuring ranges
associated with them. These ranges will vary depending on the
;;;;;;;;;;
;;; ;; ;;;

; ; ;
;;;;;;;;;; ;

Outlet Maximum Flow flowmeter model as well as the tube and float combination selected.
Obviously, the specific flowmeter chosen must be capable of mea-
A suring in the flow range required by the process. In general, for the
;
; ;
; ;
;;; ;

best accuracy, it is suggested that the flometer be sized for operation


Float
in the upper part of its range.
;

Top View at Point A


4. Accuracy: The flowmeter should be accurate to the degree re-
quired by the application. Accuracy specifications are listed for each
of our flowmeters. Generally, this will be ± 5% or ± 10% of full scale
;

(although the Series 150 flowmeters also have an optional ± 1% full


Moderate Flow scale calibration available.)
;

Full scale accuracy means that the accuracy specification is based


B
on the flowmeter’s maximum capacity. For example, a meter with a
measuring range of 1-10 slpm and an accuracy specification of
;
;

± 10% will have an actual accuracy of ± 1 slpm across its entire


Top View at Point B
range – that is, ± 10% of the maximum capacity of 10 slpm.
;

5. Repeatability: In many gas processes, the ability to duplicate


flow measurements over time is more important than the absolute
;
;

Zero Flow
accuracy of the readings. The repeatability specification shown for
each flowmeter refers to the degree to which a meter will repeat a
C
previous flow reading. In general, variable area flowmeters have very
;

good repeatability, many as high as ± 0.5% of full scale.


Inlet
F 6. Metering Valves: Flowmeters only measure flow. If adjustments
;
;

Top View at Point C


56 Figure 2 – Variable Area Flowmeter to flow rates are required, a flowmeter equipped with a metering valve
Principle of Operation should be selected.
GAS HANDLING EQUIPMENT
FLOW DEVICES
Direct Reading Flowmeters

65 MM, Direct Reading, Variable Area Flowmeters


(Series 50 and 50K)
Series 50 flowmeters offer an economical means of measuring
gas or liquid flow at low pressures where ± 10% accuracy is accept-
able. They are suitable for plant and general laboratory applications.
These flowmeters are direct reading for air; however, approximate
flow ranges for other gases are listed in the Tube Selection table below.

Standard Features
■ Ribbed tubes stabilize float and improve accuracy.
o o
■ Operating temperatures up to 250 F (100 F for Series 50K).

■ Series 50 configurated for front panel Mounting.*

■ Unique valve design allows bubble-tight shutoff.


* Series 50K Flowmeters may be front panel mounted using predrilled holes

1-877-PRAXAIR
on rear of flowmeter and self-tapping screws.

Optional Features
■ Baseplate with leveling screws permits bench use. Series 50 Flowmeter Optional Panel Mounting Bezel
■ Aluminum bezel permits flush panel mounting.

■ Inlet filter traps foreign matter, extends flowmeter life and


reduces maintenance.


Specifications Materials
■ Maximum Operating Pressure ■ Tube Graduations ■ Tubes ■ Back Plate

www.praxair.com/specialtygases
and Temperature Readings in sccm or slpm Borosilicate Glass with White Plastic
Series 50: 200 psig at 250 oF (air) (See Tube Selection Table) float stops of Teflon® ■ Front Plate
Series 50K: 150 psig at 100 oF ■ Scale Length ■ Floats Clear Plastic
■ Minimum Operating 65 mm Borosilicate Glass, Type 316 ■ Seals and Packing
Temperature: 32 oF ■ Inlet and Outlet Connections Stainless Steel or Carboloy as Viton ® (other materials available
■ Accuracy Series 50: 1/8" FPT specified in Tube Selection Table on special order)
± 10% of full scale from 10% Series 50K: 1/4" FPT ■ Side Plates ■ Valve
to 100% of range ■ Approximate Weight Aluminum Type 316 Stainless Steel
■ Repeatability 0.75 lb
Within 0.5% of full scale

Tube Selection Table For Series 50 and 50K Flowmeters – Flow rates shown are at 70°F and 14.7 psia
Tube Float Air Argon* Carbon Dioxide* Helium* Hydrogen* Nitrogen* Oxygen*
No. Material (Range) (Approx. Range) (Approx. Range) (Approx. Range) (Approx. Range) (Approx. Range) (Approx. Range)
0 Glass 8.0–50 sccm 4.3–43 sccm 6.1–61 sccm 4.7–47 sccm 10.5–105 sccm 5.1–51 sccm 4.5–45 sccm
1 Glass 5.0–85 sccm 7.1–71 sccm 10.4–104 sccm 7.9–79 sccm 17.8–178 sccm 8.7–87 sccm 9.3–93 sccm
2 Glass 40–440 sccm 38–375 sccm 36–355 sccm 52–513 sccm 0.1–1.1 slpm 45–449 sccm 41–411 sccm
3 316 SS 100–950 sccm 81–808 sccm 77–767 sccm 0.15–1.5 slpm 0.3–2.8 slpm 97–969 sccm 88–884 sccm
4 Glass 0.2–1.8 slpm 0.15–1.5 slpm 0.16–1.6 slpm 0.38–3.8 slpm 0.6–6.0 slpm 0.2–1.8 slpm 0.2–1.7 slpm
5 316 SS 0.4–3.6 slpm 0.31–3.1 slpm 0.32–3.2 slpm 0.78–7.8 slpm 1.2–12.0 slpm 0.4–3.7 slpm 0.3–3.4 slpm
6 Glass 0.5–7 slpm 0.6–5.9 slpm 0.6–5.9 slpm 1.55–15.5 slpm 2.4–23.8 slpm 0.7–7.1 slpm 0.8–8.2 slpm
7 316 SS 1.0–13 slpm 1.1–11.1 slpm 1.1–10.9 slpm 3.1–30.6 slpm 4.6–45.8 slpm 1.4–13.2 slpm 1.6–15.5 slpm
8 316 SS 6.0–24 slpm 2.1–20.5 slpm 2.0–20.1 slpm 5.7–56.4 slpm 8.5–84.5 slpm 2.5–24.5 slpm 2.9–28.7 slpm
9 Carboloy 4.0–44 slpm 3.8–37.4 slpm 3.6–36.3 slpm 10.4–103 slpm 15.5–155 slpm 4.5–44.9 slpm 5.3–52.4 slpm
* Series 50 flow tubes are directly calibrated for air at 70°F and 14.7 psia. Flow rates shown for other gases are for reference purposes only.
Flow capacities for gases not listed may be obtained by contacting your local Praxair Representative.

Optional Equipment Optional Equipment Part Number


Series Part Number End Blocks Material Inlet/Outlet Baseplate ADVFM4702
Adaptor Material Inlet Filter, 2 micron
50 ADVFM4350-( ) Aluminum Aluminum Aluminum ADVFM4741
Type 316 Stainless Steel (Series 50) ADVFM4746
50 ADVFM4360-( ) Type 316 Stn. Stl. Type 316 SS Type 316 Stainless Steel (Series 50K) ADVSG6113
50K ADVFM4451-( ) Kynar® None Aluminum Bezel for Flush Panel Mounting ADVFM4711
Where "( )" is indicated above, complete the part number by inserting applicable tube Replacement Metering Valves
number from the Tube Selection Table above. Example: ADVFM4350-5. Flowmeters with Tube Numbers FM4340 – FM4344 ADV0202-4113 (L)
Flowmeters with Tube Numbers FM4345 – FM4346 ADV0202-4114 (M)
Flowmeters with Tube Numbers FM4347 – FM4349 ADV0202-4115 (H)
Replacement Tubes and Packaging ADVFM434 ( )* F
*Where "( )" is indiacted above, complete the part number by inserting applicable tube 57
number from the Tube Selection Table above. Example: ADVFM4342.
GAS HANDLING EQUIPMENT
FLOW DEVICES
150 MM Flowmeter

150 MM, Variable Area Flowmeters (Series 150 and 150K)


Series 150 flowmeters offer an accurate yet economical means of
measuring gas or liquid flow at low pressures and over a wide range
of flow rates. Suitable for both plant and laboratory use, they are
widely used in gas chromatography, atomic absorption spectroscopy
and process control.

Standard Features
■ Two Floats per Tube (Standard) expand range of flowmeter
■ Linear Scale (10–150 mm) allows flowmeters to be used with a
variety of gases via a calibration chart.
■ Threaded Fittings with Locking Nuts (Standard on Series 150)
permit front panel mounting.*
www.praxair.com/specialtygases

■ Available in Aluminum, Stainless Steel or Kynar®


* Series 150K Flowmeters may be front panel mounted using predrilled holes
on rear of flowmeter and self-tapping screws.

Series 150 Single Tube Flow- Series 150 Four Tube Flow-
Optional Features
meter with Optional Baseplate meter with Optional Baseplate
■ Sapphire, Carboloy or Tantalum Floats allow range of flowmeter
to be changed without replacing the tube.
Calibration
■ Baseplate with Leveling Screws permits bench use.
Standard (± 5% accuracy) calibration is performed using Air at normal
■ Aluminum Bezel permits flush panel mounting.
temperature (70°F) and pressure (14.7 psia). Calibrations for gases
■ Individual Calibration provides ±1% of full scale accuracy other than Air are mathematically derived from the Air calibration.
(±2% on tube No. 1). Calibration charts for Air are shipped with each flowmeter or replace-
■ Inlet Filter traps foreign matter, extends flowmeter life and ment tube. Calibration charts for many other gases and gas mixtures
reduces maintenance. are available at no additional charge. Specify the required calibration
■ High Accuracy Valve with Non-Rotating Stem (NRS) allows charts when ordering. The accuracy of this calibration is ± 5% of full
very fine adjustments to flow scale. All charts are supplied in metric units unless otherwise specified.

1-877-PRAXAIR

Specifications Materials
■ Maximum Operating Pressure ■ Repeatability ■ Tubes ■ Side Plates
and Temperature** Within 0.5% of full scale Borosilicate Glass with float Aluminum
Series 150: 200 psig at 250 oF ■ Tube Graduations stops of Teflon® ■ Seals and Packing
Series 150K: 150 psig at 100 oF Millimeters (0–150) ■ Floats Viton ® (other materials
75 psig at 200 oF Borosilicate Glass and available)
■ Scale Length
■ Minimum Operating 150 mm Type 316 Stainless Steel are ■ Valve(s)
Temperature standard. Other materials are Models ADVFM4302, FM4602:
o
32 F ■ Inlet and Outlet Connections available – see Tube Selection
Series 150: 1/8" NPT female Chrome-Plated Brass
■ Accuracy Table (page F59) and Optional All Others:
± 5% of full scale (standard) Series 150K: 1/4" NPT female Equipment Type 316 Stainless Steel
from 10% to 100% of range. ■ Approximate Weight
Optional ± 1% is available 1 lb
** For higher operating pressures, see High Pressure,
Metal Tube Flowmeters on page F63.

Ordering Information
Single Tube Four Tube Series Configuration End Blocks Inlet/Outlet Where “( )” is indicated above under
Flowmeter Flowmeter Material Adaptor Material “Single Tube Flowmeter,” complete the
Part Number Part Number part number by inserting applicable tube
number from Tube Selection Table on
ADVFM4300-( ) ADVFM4600-( ) 150 Without Aluminum Aluminum page F59. Example: ADVFM4300-1.
ADVFM4310-( ) ADVFM4610-( ) 150 Metering Type 316 SS Type 316 SS Order by complete part number.
ADVFM4440-( ) Not Available 150K Valve Kynar® None Where “( )” is indicated above under
“Four Tube Flowmeter,” complete the
ADVFM4301-( ) ADVFM4601-( ) 150 With Standard Aluminum Aluminum part number by inserting four applicable
ADVFM4311-( ) ADVFM4611-( ) 150 Metering Type 316 SS Type 316 SS tube numbers from Tube Selection Table
ADVFM4441-( ) Not Available 150K Valve Kynar® None on page F59. Place the desired tube
numbers in the order in which they are
F ADVFM4302-( ) ADVFM4602-( ) 150 With High Aluminum Aluminum to be installed in the flowmeter, from left
ADVFM4312-( ) ADVFM4612-( ) 150 Accuracy (NRS) Type 316 SS Type 316 SS to right. Example: ADVFM4601-2314
58 ADVFM4442-( ) Not Available 150K Metering Valve Kynar® None for tube nos. 2, 3, 1 and 4. Order by
complete part number.
GAS HANDLING EQUIPMENT
FLOW DEVICES
150 MM Flowmeter (continued)

Tube Selection Table For Series 150 and 150K Flowmeters


Flow rates shown are maximum flow rates at 70 oF and 14.7 psia.
(Minimum flow rates = 1⁄10 of maximum)

Tube Float Air Argon Carbon Helium Hydrogen Nitrogen Oxygen Water Replacement Tubes
Number Material* slpm slpm Dioxide slpm slpm slpm slpm ccm and Packing
slpm Part Number
1 Glass 0.050 0.041 0.059 0.045 0.101 0.051 0.044 0.551 ADVFM4331
Sapphire 0.077 0.063 0.088 0.071 0.160 0.080 0.069 1.08
316 SS 0.148 0.122 0.160 0.145 0.323 0.152 0.133 2.56
Carboloy 0.251 0.208 0.268 0.269 0.592 0.258 0.228 5.02
Tantalum 0.274 0.227 0.293 0.299 0.653 0.282 0.249 5.58
2 Glass 0.088 0.072 0.103 0.083 0.185 0.091 0.078 1.01 ADVFM4332
Sapphire 0.136 0.111 0.154 0.130 0.288 0.140 0.121 1.96

1-877-PRAXAIR
316 SS 0.258 0.213 0.278 0.262 0.574 0.266 0.232 4.56
Carboloy 0.439 0.363 0.446 0.483 1.04 0.451 0.398 8.80
Tantalum 0.478 0.396 0.481 0.535 1.14 0.491 0.434 9.77
3 Glass 0.380 0.318 0.358 0.494 1.03 0.389 0.351 5.94 ADVFM4333
Sapphire 0.518 0.433 0.482 0.759 1.49 0.529 0.479 10.71
316 SS 0.832 0.697 0.754 1.41 2.53 0.849 0.771 20.9
Carboloy 1.24 1.04 1.10 2.29 3.87 1.26 1.15 33.6
Tantalum 1.33 1.11 1.17 2.47 4.16 1.35 1.23 36.2
A Glass 0.830 0.701 0.741 1.55 2.62 0.848 0.777 17.0 ADVFM4333A


Sapphire 1.10 0.926 0.974 2.15 3.53 1.12 1.03 26.6
316 SS 1.69 1.42 1.47 3.44 5.55 1.72 1.58 46.6

www.praxair.com/specialtygases
Carboloy 2.44 2.06 2.11 5.16 8.15 2.49 2.30 71.3
Tantalum 2.60 2.19 2.25 5.52 8.70 2.64 2.44 76.4
4 Glass 2.37 2.00 2.06 5.03 7.99 2.41 2.22 53.3 ADVFM4334
Sapphire 3.08 2.60 2.68 6.69 10.5 3.14 2.89 80.2
316 SS 4.65 3.92 4.02 10.3 15.9 4.74 4.36 134.0
Carboloy 6.67 5.64 5.65 15.0 22.8 6.81 6.27 199.7
Tantalum 7.09 5.99 5.97 15.9 24.3 7.23 6.66 213.2
B Glass 3.89 3.28 3.37 8.01 12.9 3.96 3.65 85.4 ADVFM4334B
Sapphire 5.06 4.27 4.35 10.7 17.0 5.15 4.76 129.8
316 SS 7.61 6.44 6.34 16.7 26.0 7.74 7.17 219.8
Carboloy 10.65 9.03 8.79 24.5 37.4 10.8 10.1 328.6
Tantalum 11.25 9.54 9.29 26.1 39.8 11.4 10.6 350.7
5 Glass 8.68 7.34 7.39 19.3 29.9 8.85 8.16 202.1 ADVFM4335
Sapphire 11.2 9.46 9.47 25.3 38.9 11.4 10.5 299.1
316 SS 16.5 14.0 13.9 38.4 58.4 16.8 15.6 492.8
Carboloy 23.2 19.6 19.4 55.1 82.9 23.6 21.9 726.4
Tantalum 24.5 20.8 20.5 58.5 87.9 25.0 23.2 773.4
6 Glass 23.7 20.1 19.6 55.5 85.4 24.2 22.5 580.4 ADVFM4336
Sapphire 30.1 25.5 25.0 72.7 110.0 30.6 28.5 853.1
316 SS 43.7 37.0 36.5 109.4 160.3 44.5 41.3 1362.0
Carboloy 61.1 51.8 50.9 153.2 222.0 62.2 57.7 1952.0
Tantalum 64.6 54.8 53.8 162.0 234.5 65.8 61.0 2069.0
Flow capacities for gases not listed may be obtained from your local Praxair representative.
* Series 150 flow tubes are supplied standard with both a glass and stainless steel float.
Other float materials listed are optional. See Optional Equipment below.

Optional Equipment
Part Number Description Part Number Description
ADVFM4702 Base plate-Fits single or four tube flowmeters ADVS1000 Sapphire Float – Tube Numbers ADVFM4331 - ADVFM4334B*
ADVFM4741 Inlet Filter, 2 micron, Aluminum ADVS1001 Sapphire Float – Tube Numbers ADVFM4335 - ADVFM4336*
ADVFM4746 Inlet Filter, 2 micron, Type 316 SS (Series 150) ADVC1000 Carboloy Float – Tube Numbers ADVFM4331 - ADVFM4334B*
ADVSG6113 Inlet Filter, 2 micron, Type 316 SS (Series 150K) ADVC1001 Carboloy Float – Tube Numbers ADVFM4335 - ADVFM4336*
ADVFM4710 Aluminum Bezel for Flush Panel Mounting ADVT1000 Tantalum Float – Tube Numbers ADVFM4331 - ADVFM4334B*
(single tube version only) ADVT1001 Tantalum Float – Tube Numbers ADVFM4335 - ADVFM4336*
ADVCC100 ± 1% Full Scale Calibration* * (one tube, both floats)
* Tubes are supplied standard with borosilicate glass and stainless steel floats. ** Specify gas, temperature and pressure when ordering a ±1% calibration.
F
As an option, the glass float may be replaced by sapphire; the stainless steel float Please note the accuracy for tube No. 1 is ±2%.
may be replaced by either carboloy or tantalum. 59
GAS HANDLING EQUIPMENT
FLOW DEVICES
Gas Blenders

150 MM, Two Tube Gas Blenders (Series 150)


This blender is a special version of our Series 150 flowmeter.
It allows two gases to be metered and blended into a homo-
geneous, two-component mixture.

Standard Features
■ Two floats per tube ■ Metal mixing tube ensures ■ Linear scale (10–150 mm)
(standard) expand range homogeneous mixing while allows each blender to be
of blender. providing a common outlet used with a variety of gases
■ Ribbed flow tubes stabilize port for the gas mixture. via calibration charts.
floats and improve accuracy ■ Wide tube selection allows ■ Threaded fittings with
and readability. gases to be blended in a locking nuts permit
variety of ratios. front panel mounting.
www.praxair.com/specialtygases

■ Unique valve design allows


bubble-tight shutoff.

Optional Features
■ Baseplate with leveling ■ High accuracy valves with ■ Individual calibration provides
screws permits bench use. non-rotating stems (NRS) ± 1% of full scale accuracy Two Tube Gas Blender with
■ Inlet filters trap foreign matter, allow very fine adjustments to (±2% on tube No. 1).
Optional Baseplate
extend flowmeter life and flow settings (see Ordering
reduce maintenance. Information below).

Specifications Materials
■ Maximum Operating Pressure ■ Repeatability ■ Tubes ■ Side Plates
and Temperature Within 0.5% of full scale Borosilicate Glass with Aluminum
200 psig at 250 °F (each tube) float stops of Teflon® ■ Back Plate

■ Minimum Operating ■ Tube Graduations ■ Mixing Tube White Plastic


Temperature Millimeters (0–150) Type 316 Stainless Steel ■ Front Plate
1-877-PRAXAIR

32 °F ■ Scale Length ■ Floats Clear Plastic


■ Accuracy 150 mm Borosilicate Glass and Type ■ Seals and Packing
± 5% of full scale from 10% to ■ Inlet and Outlet Connections 316 Stainless Steel are stan- Viton ® (other materials
100% of range (each tube). 1/8" FPT (2 inlets, 1 outlet) dard. Other float materials are available on special order)
Optional available – see Tube Selection
± 1% of full scale calibration ■ Approximate Weight Table (page F59) and Optional ■ Valves
is available 2 lb Equipment, below Model FM4621
Chrome-Plated Brass
■ End Blocks All Others
See Ordering Information Type 316 Stainless Steel
■ Inlet/Outlet Adaptors
See Ordering Information

Ordering Information
Part Number Configuration End Blocks Material Inlet/Outlet Adaptor Material
ADVFM-4620-( ) With Standard Metering Valves Aluminum Aluminum
ADVFM-4621-( ) With High Accuracy (NRS) Metering Valves Aluminum Aluminum
ADVFM-4630-( ) With Standard Metering Valves 316 Stainless Steel 316 Stainless Steel
ADVFM-4631-( ) With High Accuracy (NRS) Metering Valves 316 Stainless Steel 316 Stainless Steel
Where “( )” is indicated above, complete the part number by inserting the required tube numbers in the order in which they are to be installed.
Select tubes from Tube Selection Table on page F 59. Example: ADVFM4620-12, tube no. 1 will be on the left and tube no. 2 on the right.

Optional Equipment
Part Number Description Part Number Description
ADVFM4702 Base plate ADVCC100 ± 1% Full Scale Calibration**
ADVFM4741 Inlet filter, 2 micron Aluminum (2 required) (one tube, both floats)
ADVFM4746 Inlet filter, 2 micron Type 316 Stainless Steel (2 required) See page F59 Floats* (see Optional Equipment Table)

F * Tubes are supplied standard with borosilicate glass and stainless steel floats. ** Specify gas, temperature and pressure when ordering a ±1% calibration.
As an option, the glass float may be replaced by sapphire; the stainless steel float A calibration should be ordered for each of the two tubes. Please note the
60 may be replaced by either carboloy or tantalum. accuracy for tube No.1 is ±2%.
GAS HANDLING EQUIPMENT
FLOW DEVICES
High Capacity Flowmeters

High Capacity, Variable Area Flowmeters (Series 50HC)


Series 50HC flowmeters offer a means of measuring gas or liquid
flows at capacities higher than our other variable area flowmeters (up
to 15 scfm air). They are suitable for both plant and laboratory use.

Standard Features
■ Large diameter flow tubes ■ Borosilicate glass tubes
permit flows as high as allow operating temperatures
15 standard cubic feet up to 200 °F.
per minute (scfm) of air. ■ Brass or stainless steel
■ Ribbed tubes stabilize float construction permits use
and improve accuracy and in either corrosive or
readability. noncorrosive gas service.

1-877-PRAXAIR
Specifications 50HC Series
Flowmeter
■ Maximum Operating Pressure ■ Repeatability
and Temperature Within 0.5% of full scale
200 psig at 200 °F ■ Tube Graduations
minimum operating scfm of air
■ Minimum Operating ■ Scale Length
Temperature Table 1 – Gas Conversion Factors for Series 50HC Flowmeters


75 mm
32 °F (0 °C)
■ Inlet and Outlet Connections To select the proper tube for gases other than air, multiply flow

www.praxair.com/specialtygases
■ Accuracy 3/8" FPT rate values for air given in the Tube Selection Chart below by the
± 10% of full scale from applicable conversion factor. Then use these new flow rate values
10% to 100% of range ■ Approximate Weight
2.5 lb to select appropriate tube number.

Gas Factor* Gas Factor*


Materials Acetylene 1.04 Helium 2.69
■ Tube ■ Back Plate Ammonia 1.30 Hydrogen 3.81
Borosilicate Glass White Plastic Argon 0.85 Methane 1.35
■ Float and Float Stops ■ Front Plate Butane 0.70 Neon 1.20
Type 316 Stainless Steel Clear Plastic
Carbon Dioxide 0.81 Nitrogen 1.01
■ End Blocks ■ Seals and Packing
See Ordering Information Viton ® Carbon Monoxide 1.01 Oxygen 0.95

■ Inlet/Outlet Adaptors ■ Metering Valve Ethane 0.98 Propane 0.80


See Ordering Information Chrome-Plated Brass or Ethylene 1.02 Sulfur Dioxide 0.66
■ Side Plates 316 Stainless Steel * Conversion factors are approximately equal to square root of the reciprocal
Aluminum of the specific gravity of the gas ( 1/SG).

Ordering Information
Series 50HC Flowmeters Tube Selection Chart for Series 50HC Flowmeters
Part Number Metering Valve, End Blocks and Replacement Tube Tubes Air Flow Rate Range
Inlet/Outlet Adaptor Material Part Number Number at 70 °F and 14.7 psia
ADVFM4470-( ) Chrome-Plated Brass ADVFM4471 1 0.6–3.4 scfm
ADVFM4480-( ) Type 316 Stainless Steel ADVFM4472 2 0.6–6.0 scfm
Where “( )” is indicated above, complete the part number by inserting applicable ADVFM4473 3 1.2–12.0 scfm
tube number from the Tube Selection Chart to the right. Example: ADVFM4470-1 ADVFM4474 4 1.5–15.0 scfm
which has a flow range of 0.6 to 3.4 scfm. Order by complete part number.

F
61
GAS HANDLING EQUIPMENT
FLOW DEVICES
Variable Area Flowmeters

Plastic, Variable Area Flowmeters (Series 50PM)


Series 50PM flowmeters provide an economical means for low flow measurement
and control of noncorrosive liquids and gases.
Warning: This flowmeter is constructed of polycarbonate plastic. Make certain
the gas you are using is compatible with the materials of construction. Injury to
personnel or damage to equipment may result.

Standard Features
■ Ribbed tubes stabilize float and improve ■ Unique valve design allows bubble-tight
accuracy and readability. shutoff.
■ Large numbers and graduations ■ Integral bezel and threaded mounting
enhance readability. screw permits either flush or front panel
50PM Series
mounting.
www.praxair.com/specialtygases

■ Dual scale allows flow rate to be read Flowmeter


in standard liters per minute (slpm) and ■ Metal connection inserts prevent
standard cubic feet per hour (scfh). damage from overtightening fittings.

Specifications Materials
■ Maximum Operating Pressure ■ Tube Graduations ■ Body and Tube
and Temperature Standard liters per minute (slpm) and Polycarbonate Plastic
100 psig at 130 °F standard cubic feet per hour (scfh) of air ■ Float
■ Minimum Operating Temperature ■ Scale Length See Ordering Information
32 °F 37 mm ■ Connection Fittings and Valve
■ Accuracy ■ Inlet and Outlet Connections Type 316 Stainless Steel
± 10% of full scale from 1/8" FPT ■ Seals
10% to 100% of range ■ Approximate Weight Viton®
■ Repeatability 0.25 lb
Within 1% of full scale

1-877-PRAXAIR

Ordering Information
Air Flow Rate Range at 70 °F and
14.7 psia Actual Graduations
Part Number Float Material scfh slpm
ADVFM4491 Glass 0.3–3.0 0.15–1.5
ADVFM4492 316 Stainless Steel 0.5–5.5 0.25–2.5
ADVFM4493 Glass 1.0–10.0 0.50–5.0
ADVFM4494 316 Stainless Steel 2.0–20.0 1.00–10.0
ADVFM4495 Glass 5.0–50.0 2.50–25.0
ADVFM4496 316 Stainless Steel 10.0–100.0 5.00–50.0

F
62
GAS HANDLING EQUIPMENT
FLOW DEVICES
High Pressure, Metal Tube Flowmeters

High Pressure, Metal Tube, Variable Area Flowmeters


(FM4460N Series)
These flowmeters offer economical low flow rate indication in applications where glass tube
meters are not practical because of high pressure, high temperature or hazardous fluids.

Standard Features
■ 316L stainless steel metal flow tubes ■ Unique valve design allows bubble-tight
allow operation up to 1500 psig. shutoff.
■ Type 316L stainless steel and Viton® ■ Threaded holes on rear of flowmeter
construction provides excellent corrosion permit front panel mounting.
resistance.

1-877-PRAXAIR
Optional Features
■ Inlet filter traps foreign matter, extends FM4460N Series
flowmeter life and reduces maintenance. Flowmeter

Specifications
■ Maximum Operating Pressure ■ Repeatability ■ Inlet and Outlet Connections


and Temperature Within 1% of full scale 1/4" NPT female
1500 psig at 400 °F

www.praxair.com/specialtygases
■ Tube Graduations ■ Approximate Weight
■ Accuracy Standard liters per minute (slpm) of air 2 lb
± 5% of full scale from ■ Scale Length
10% to 100% of range 55 mm

Materials
■ Tubes, Fittings, Clean-Out ■ Housing ■ Seals
Plug and Float Stop Epoxy Painted Aluminum Viton®
Type 316L Stainless Steel ■ Float ■ Valve
Type 316 Stainless Steel Type 316L Stainless Steel
■ Float Stop Spring
Inconel® 625

Ordering Information Optional Equipment


Air Flow Rate Range at 70°F and 14.7 psia Part Number Description
Part Number Actual Graduations (slpm) Reference (scfh) ADVSG6113 Inlet Filter,
ADVFM4460N 0.1–1.0 0.2–2.2 Type 316 Stainless Steel,
2 micron
ADVFM4461N 0.2–2.3 0.5–5.0
ADVFM4462N 0.6–6.0 1.3–13
ADVFM4463N 1.1–11 2.4–24
ADVFM4464N 2.6–26 5.5–55
ADVFM4465N 5.6–56 12–120

F
63
GAS HANDLING EQUIPMENT
FLOW DEVICES
Mass Flowmeters/Controllers/Blending

Mass Flow Measuring, Controlling and Blending Systems


Using state-of-the-art measuring and microprocessor technologies, Praxair has assembled
a series of systems which can measure the mass flow rate of gas streams; measure and
control mass flow rate; or perform gas blending operations – all with extremely high accuracy.
These systems consist of an Operator Console that is electronically coupled to one or more
Mass Flow Sensors and/or Mass Flow Control Modules.

Mass Flow Sensors 2. Model FM4595 can be used for flow Materials of Construction
measurement or for flow measurement
Mass Flow Sensors measure gas flow with All wetted parts of these systems (parts in
and flow control. It will operate with
a ± 1% of full scale accuracy. Since they do contact with the gas) are of stainless steel
1 Mass Flow Sensor or 1 Mass Flow
not control gas flow, Mass Flow Sensors are construction with Viton® used as a sealing
Control Module.
only used in applications requiring flow mea- material. Other seal materials (Buna-N®
surement. Capable of working with any of 3. Model FM4575A can be used for flow or Kalrez®) are available on special order,
our Operator Consoles, Mass Flow Sensors measurement and flow control or for gas allowing these systems to be used in nearly
www.praxair.com/specialtygases

are available for measuring flow rates in ran- blending applications. It will operate with any gas service.
ges as low as 0.1-5 sccm to ranges as high up to four Mass Flow Control Modules to:
as 20-1000 slpm. For complete specifica- ■ Provide simultaneous measurement and Selecting Mass Flow Measuring
tions on flow sensors, see pages F68 and control of four separate gas streams, or and Control Systems
F69. ■ Produce gas mixtures of two to four
1. Review the Operator Console features on
components.
page F67 and select the console that
Mass Flow Control Modules Note: Mass Flow Sensors may also be used
meets your requirements.
Mass Flow Control Modules measure flow with Model FM4575A for any gas streams
requiring flow measurement only. Provided 2. Review the specifications on page F68
using the same principles as our Mass Flow and determine the type of flow control
with a standard RS232 serial interface port,
Sensors. However, they also feature an in- or sensing devices required for your
tegral electromagnetic control valve that the FM4575A can be coupled to an external
computer for automated operation. operation. Then select the appropriate
gives them the ability to control gas flows model number. Note: As previously dis-
with a ± 1% of full scale accuracy. Based 4. Model FM4660A is used for applications
cussed, Mass Flow Control Modules are
on this control capability, they can also be requiring flow measurement and flow
used where both measurement and control
used to perform gas blending operations. control. It operates with up to eight Flow are desired, or for gas blending applica-
Control Modules (or Sensors if desired).

Available in two different models, all Mass tions. Mass Flow Sensors are used in app-
This model features:
Flow Control Modules are capable of work- lications requiring flow measurement only.
1-877-PRAXAIR

ing with either our FM4595, FM4575A or ■ Built-in totalizers that maintain a record
3. Review the applicable selection guide on
FM4660A Operator Consoles. Each model of cumulative gas usage through each page F69 and choose the flow range(s)
is equipped with a user selectable “soft of the control modules or sensors.
required for your operation.
start” feature* which, when enabled, virtu- ■ An 80-character liquid crystal display

ally eliminates any overshoot and under- (LCD) which simultaneously displays the Selecting Gas Blending Systems
shoot in flow settings. flow readings from all eight channels.
■ An RS232 serial interface port for com- 1. Review the Operator Console features
1. Model FRC, Fast Response Control
puter controlled operation or for data on page F67 and select the console for
Modules, are offered in ranges from
logging requirements. your needs. As shown in Table 1, the
0.1-5 sccm through 20-1000 slpm.
The FM4660A can also be used for gas choices for blending applications are limi-
2. Model HPC, High Pressure Control ted to models FM4575A and FM4660A.
blending, having the ability to manufacture
Modules, can operate at inlet pressures
gas mixtures of two to eight components. 2. Select the appropriate range for each
as high as 4500 psig. They are available
This sophisticated console can perform Mass Flow Control Module. This can be
for flow ranges from 2-100 sccm up to
blending operations while simultaneously done by determining the total mixture
0.4-20 slpm.
measuring and/or controlling gas flows. flow required and multiplying this by the
For complete specifications on Control For specifications on Operator Consoles, percentage composition that each com-
Modules, see pages F68 and F69. ponent represents in the mixture. Then
see page F67.
compare this to the flow ranges available
Operator Consoles Interconnecting Cables in Table 5 (page F69).
Operator Consoles are available in four 3. Review the specifications in Table 3
Interconnecting cables are used in all sys-
different models-each capable of handling tems for coupling the Flow Sensors and (page F68 and select the model number
a number of specific functions. of the desired control module.
Control Modules to the operator console.
1. Model FM4560A is used when only flow One cable is provided with each Sensor or Note: In blending systems, the outlets of flow
measurement is desired. It can operate Control Module purchased. With these 25 control modules must be manifolded together
with up to six separate Mass Flow Sen- foot cables, the Operator Console can be to create the blend. Therefore to prevent the
sors, allowing simultaneous measure remotely located away from the sensors possibility of back-flow from one module to
F ment of six gas streams. Since this con- and control modules. This enhances the another, it is strongly recommended that you
sole does not offer a command signal, operator’s safety-especially when working select proper check valves and install them at
64
it cannot be used with Mass Flow with toxic or otherwise hazardous gases. the outlet of each module. See page F113 for
Control Modules. check valves available from Praxair.
GAS HANDLING EQUIPMENT
FLOW DEVICES
Mass Flowmeters/Controllers/Blending

Typical System using


FM4560A Operator Console
for Flow Measurement

Note: Although not shown, relief


devices should be incorporated in
all gas handling systems to protect
against over-pressurization. Contact
your Praxair representative for more
information.

1-877-PRAXAIR
Typical System using
FM4595 Operator Console


for Flow Measurement

www.praxair.com/specialtygases
and Control

Note: Although not shown, relief


devices should be incorporated in
all gas handling systems to protect
against over-pressurization. Contact
your Praxair representative for more
information.

Typical System using


FM4575A Operator Console
for Flow Measurement
and Control

Note: Although not shown, relief


devices should be incorporated in
all gas handling systems to protect
against over-pressurization. Contact
your Praxair representative for more
information.

F
65
GAS HANDLING EQUIPMENT
FLOW DEVICES
Mass Flowmeters/Controllers/Blending

Typical System using


FM4575A Operator Console
for Gas Blending

Note: Although not shown, relief


devices should be incorporated in
all gas handling systems to protect
against over-pressurization. Contact
your Praxair representative for more
information.
www.praxair.com/specialtygases

Typical System using


FM4660A Operator Console
for Flow Measurement
and Control

Note: Although not shown, relief


devices should be incorporated in
all gas handling systems to protect
against over-pressurization. Contact
your Praxair representative for more

information.
1-877-PRAXAIR

Typical System using


FM4660A Operator Console
for Measuring, Controlling
and Blending

Note: Although not shown, relief


devices should be incorporated in
all gas handling systems to protect
against over-pressurization. Contact
your Praxair representative for more
information.

F
66
GAS HANDLING EQUIPMENT
FLOW DEVICES
Mass Flowmeter Operator Consoles

FM4660A Operator Console FM4575A Operator Console FM4595 Operator Console FM4560A Operator Console

Front View Front View Front View Front View

1-877-PRAXAIR
Rear View Rear View Rear View Rear View

Table 1 – Operator Console Features


Part Number Part Number Part Number Part Number
ADVFM4660A ADVFM4575A ADVFM4595 ADVFM4560A

www.praxair.com/specialtygases
Number of Channels 8 4 1 6
Flow Measurement yes (1) yes (1) yes (1) yes (1)
Flow Measurement and Control yes (2) yes (2) yes (2) no
Blending Capabilities yes (3) yes (4) no no
RS232 Serial Interface yes yes no no
Recorder/Totalizer Connection yes (0-5 VDC signal yes (0-5 VDC signal yes (0-5 VDC signal yes (0-5 VDC signal
for each channel for each channel for each channel for each channel
proportional to flow) proportional to flow) proportional to flow) proportional to flow)
Totalization Capabilities yes optional optional optional
Solid State Keypad yes (20-key) yes (16-key) no no (selector switch)
Display 80 character LCD 4 digit LED 4 digit LED 3-1/2 digit LED
Simultaneous Display of All Channels yes no yes no
Non-Volatile Memory yes no not applicable not applicable
Bench Mounting yes yes yes yes
(1) When used with Praxair Mass (2) When used with Praxair Mass (3) Two to eight component mixtures (4) Two to four component mixtures
Flow Sensors. Flow Control Modules. may be produced when used with may be produced when used with
Praxair Mass Flow Control Modules. Praxair Mass Flow Control Modules.

Table 2 – Operator Console Specifications


Part Number Part Number Part Number Part Number
ADVFM4660A ADVFM4575A ADVFM4595 ADVFM4560A
Operating Temperature 0 oF to 150 oF 0 oF to 150 oF 0 oF to 150 oF 0 oF to 150 oF
Electrical Power Requirements 105/120 VAC; 105/120 VAC; 105/120 VAC; 105/120 VAC;
220/240 VAC 50/60 Hz 220/240 VAC 50/60 Hz 220/240 VAC 50/60 Hz 220/240 VAC 50/60 Hz
Power Cord Length 7 ft 7 ft 7 ft 7 ft
Power Cord Connection 105/120 VAC; 105/120 VAC; 105/120 VAC; 105/120 VAC;
3-pin grounding plug 3-pin grounding plug 3-pin grounding plug 3-pin grounding plug
220/240 VAC; no 220/240 VAC; no 220/240 VAC; no 220/240 VAC; no
connector provided connector provided connector provided connector provided
RS232 Connection 25-Pin Type “D” 25-Pin Type “D” not applicable not applicable
Female Connector Female Connector
Dimensions (inches) H x W x D 5.75 x 12.5 x 11.4 4.88 x 12.5 x 11.4 2.68 x 6.12 x 6.5 4.88 x 12.5 x 11.4
F
Weight (approximate) 7 lb 8 lb 2 lb 6 lb
67
GAS HANDLING EQUIPMENT
FLOW DEVICES
Mass Flowmeters and Controllers

Mass Flow Control Module and Sensor Features and Specifications

Fast Response Mass Fast Response Mass Fast Response Mass High Pressure Mass
Flow Control Module Flow Control Module Flow Control Module Flow Control Module
(1FRC-17FRC) with (18FRC-19FRC) (20FRC-24FRC) (6HPC-16HPC)
Optional Inlet Filter

Table 3 – Mass Flow Control Module Specifications


Fast Response Modules Fast Response Modules Fast Response Models High Pressure Modules
Models 1FRC-17FRC Models 18FRC-19FRC 20FRC-24FRC 6HPC-16HPC
Operating Pressure Range 570 torr to 1500 psig 570 torr to 1500 psig 570 torr to 1500 psig 570 torr to 4500 psig
Operating Temperature Range 40 oF to 150 oF 40 oF to 150 oF 40 oF to 150 oF 40 oF to 150 oF
Maximum Flow Capacity See Table 5 See Table 5 See Table 5 See Table 5
www.praxair.com/specialtygases

Minimum Flow Capacity 2% of max. flow capacity 2% of max. flow capacity 2% of max. flow capacity 2% of max. flow capacity
Accuracy ± 1% of full scale ± 1% of full scale ± 1% of full scale ± 1% of full scale
Repeatability ± 0.25% of reading ± 0.25% of reading ± 0.25% of reading ± 0.25% of reading
Response Time 3 seconds max (1) 3 seconds max (1) 3 seconds max (1) 15 seconds max (1)
Maximum Pressure Drop 50 psi differential 50 psi differential 290 psi differential 50 psi differential
Minimum Pressure Drop 5 psi differential 10 psi differential 22 psi differential 5 psi differential
Mounting Attitude Sensitivity ± 0.5% full scale(2) ± 0.5% full scale(2) ± 0.5% full scale(2) ± 0.25% full scale (2)
Inlet and Outlet Connections 1/4" Swagelok®(3) 3/8" Swagelok®(3) 1/2" NPT female (5) 1/4" Swagelok®(3)
Leak Integrity 1 x 10-9 atm. scc/sec He 1 x 10-9 atm. scc/sec He 1 x 10-9 atm. scc/sec He 1 x 10-9 atm. scc/sec He
Dimensions (inches) H x W x L 5.48 x 1.48 x 5.02 (4) 5.68 x 1.75 x 5.82 (4) 7.00 x 3.30 x 7.9 4.92 x 1.00 x 5.05 (4)
Weight (approximate) 2.5 lb 3 lb 15 lb 1.5 lb
Electrical Connection 15-Pin Type “D” male 15-Pin Type “D” male con. 15-Pin Type “D” male con. 15-Pin Type “D” male con.
Power Requirements +15 VDC at 35mA +15 VDC at 350mA +15 VDC at 35mA +15 VDC at 215mA
-15 VDC at 180mA -15 VDC at 350mA -15 VDC at 180mA -15 VDC at 15mA
Flow Output Signal 0-5 VDC into 2000 ohm 0-5 VDC into 2000 ohm 0-5 VDC into 2000 ohm 0-5 VDC into 2000 ohm
(or greater) load (or greater) load (or greater) load (or greater) load
Command Signal 0-5 VDC 0-5 VDC 0-5 VDC 0-5 VDC
(1) To within 2% of set point. Response time specification shown is with (3) VCR® connections are available (5) 1" or 1-1/2" NPT or 1/2", 3/4"

“soft start” feature disabled. With soft start enabled, response time will on special order. or 1" Swagelok® Connections
increase by a factor of approximately 4 to 5 times stated specification. (4) Dimensions include Swagelok® available on special order.
1-877-PRAXAIR

Modules are shipped with this feature disabled. end connectors.


(2) Maximum deviation from stated accuracy specification.

Fast Response Fast Response Fast Response


Mass Flow Sensor Mass Flow Sensor Mass Flow Sensor
(1FRM-17FRM) with (18FRM-19FRM) (20FRM-24FRM)
Optional Inlet Filter

Table 4 – Mass Flow Sensor Specifications


Fast Response Sensor Fast Response Sensors Fast Response Sensors
Models 1FRM – 17FRM Models 18FRM – 19FRM Models 20FRM – 24FRM
Operating Pressure Range 570 torr to 4500 psig 570 torr to 1500 psig 570 torr to 1500 psig
Operating Temperature Range 40 oF to 150 oF 40 oF to 150 oF 40 oF to 150 oF
Maximum Flow Capacity See Table 5 See Table 5 See Table 5
Minimum Flow Capacity 2% of maximum flow capacity 2% of maximum flow capacity 2% of maximum flow capacity
Accuracy ± 1% of full scale ± 1% of full scale ± 1% of full scale
Repeatability ± 0.25% of full scale ± 0.25% of full scale ± 0.25% of full scale
Response Time 3 seconds max (1) 3 seconds max (1) 3 seconds max (1)
Pressure Drop 10" water column at maximum flow 10" water column at maximum flow 10" water column at maximum flow
Mounting Attitude Sensitivity ±0.5% of Full Scale (2) ±0.5% of Full Scale (2) ±0.5% of Full Scale (2)
Inlet and Outlet Connections 1/4" Swagelok®(3) 3/8" Swagelok®(3) 1/2" NPT female (5)
Dimensions (inches) H x W x L 5.50 x 1.48 x 4.32(4) 5.50 x 1.48 x 4.32 (4) 7.00 x 3.30 x 6.10
Weight (approximate) 2 lb 2 lb 13 lb
Electrical Connection 15-pin Type “D” male connector 15-pin Type “D” male connector 15-pin Type “D” male connector
Power Requirements +15 VDC at 35mA -15 VDC at 35mA +15 VDC at 35mA -15 VDC at 35mA +15 VDC at 35mA -15 VDC at 35mA
Flow Output Signal 0-5 VDC into 3000 ohm 0-5 VDC into 3000 ohm 0-5 VDC into 3000 ohm
F (or greater) load (or greater) load (or greater) load
68 (1) To within 2% of set points. (3) VCR ® connections are available (4) Dimensions include Swagelok® (5) 1" or 1-1/2" NPT or 1/2", 3/4" or 1"
(2) Maximum deviation from stated on special order. end connectors. Swagelok® Connections available
accuracy specification. on special order.
GAS HANDLING EQUIPMENT
FLOW DEVICES
Mass Flowmeters and Controllers (continued)

Mass Flow Control Module and Sensor Ordering Information

Table 5 – Mass Flow Control Modules and Sensors Selection Guide

Model Numbers Maximum Flow Capacity (Minimum Capacity = 2% of Maximum)

Fast High Fast Air, Argon, Ammonia, Arsine, Acetylene, Ethane, Dichlorosilane,
Response Pressure Response Carbon Monoxide, Carbon Dioxide, Ethylene, Silane, Halocarbon 12,
Control Control Sensors Deuterium, Helium**, Chlorine, Sulfur Dioxide Halocarbon 13,
Modules Modules Hydrogen**, Krypton, Hydrogen Chloride, Halocarbon 13B1,
Neon, Nitrogen, Hydrogen Sulfide, Halocarbon 14,
Oxygen, Xenon Methane, Isobutane, Propane,
Nitrous Oxide, Propylene,
Phosphine Sulfur Hexafluoride
ADV1FRC – ADV1FRM 5 sccm* – – –

1-877-PRAXAIR
ADV2FRC – ADV2FRM 10 sccm* 5 sccm* – –
ADV3FRC – ADV3FRM 20 sccm 10 sccm* 5 sccm* –
ADV4FRC – ADV4FRM 30 sccm 20 sccm 10 sccm* 5 sccm*
ADV5FRC – ADV5FRM 50 sccm 30 sccm 20 sccm 10 sccm*
ADV6FRC ADV6HPC ADV6FRM 100 sccm 50 sccm 30 sccm 20 sccm
ADV7FRC ADV7HPC ADV7FRM 200 sccm 100 sccm 50 sccm 30 sccm
ADV8FRC ADV8HPC ADV8FRM 300 sccm 200 sccm 100 sccm 50 sccm


ADV9FRC ADV9HPC ADV9FRM 500 sccm 300 sccm 200 sccm 100 sccm

www.praxair.com/specialtygases
ADV10FRC ADV10HPC ADV10FRM 1,000 sccm 500 sccm 300 sccm 200 sccm
ADV11FRC ADV11HPC ADV11FRM 2,000 sccm 1,000 sccm 500 sccm 300 sccm
ADV12FRC ADV12HPC ADV12FRM 3,000 sccm 2,000 sccm 1,000 sccm 500 sccm
ADV13FRC ADV13HPC ADV13FRM 5,000 sccm 3,000 sccm 2,000 sccm 1,000 sccm
ADV14FRC ADV14HPC ADV14FRM 10 slpm 5,000 sccm 3,000 sccm 2,000 sccm
ADV15FRC ADV15HPC ADV15FRM 15 slpm 10 slpm 5,000 sccm 3,000 sccm
ADV16FRC ADV16HPC ADV16FRM 20 slpm 15 slpm 10 slpm 5,000 sccm
ADV17FRC – ADV17FRM 30 slpm 20 slpm 15 slpm 10 slpm
ADV18FRC – ADV18FRM 50 slpm 30 slpm 20 slpm 15 slpm
ADV19FRC – ADV19FRM 100 slpm 50 slpm 30 slpm 20 slpm
ADV20FRC – ADV20FRM 150 slpm 100 slpm 50 slpm 30 slpm
ADV21FRC – ADV21FRM 200 slpm 150 slpm 100 slpm 50 slpm
ADV22FRC – ADV22FRM 300 slpm 200 slpm 150 slpm 100 slpm
ADV23FRC – ADV23FRM 500 slpm 300 slpm 200 slpm 150 slpm
ADV24FRC – ADV24FRM 1,000 slpm 500 slpm 300 slpm 200 slpm
* Mass Flow Control Modules ordered When ordering, specify gas service, operating pressure, operating temperature One 25 ft. interconnecting cable will be
for flow capacities of 10 sccm or less and flow range for each module and sensor. Calibration for one service gas (or gas included with each Mass Flow Control
carry an additional low flow calibration mixture) at pressures up to 200 psig on models 1FRC-17FRC and 1FRM -17FRM, Module and Sensor ordered.
charge. (See Optional Equipment 90 psig on models 18FRC-24FRC and 18FRM-24FRM, and 4500 psig on models
Table, below). 6HPC-16HPC is included. Calibrations on models 1FRC-17FRC and 1FRM-17FRM
** Minimum flow range of 20 sccm for pressures above 200 psig and above 90 psig on models 18FRC-19FRC and
available for hydrogen and helium. 18FRM-19FRM are available as an option. (See Optional Equipment Table, below).

Optional Equipment
Part Number Description
Inlet Filter, High Purity, Type 316 Stainless Steel ADVFM4800 0.5 micron Filter, Viton Seal*
(fits between sensor and inlet fitting) ADVFM4802 2 micron Filter, Viton Seal*
ADVFM4805 5 micron Filter, Viton Seal*
ADVFM4810 10 micron Filter, Viton Seal*
ADVFM4840 40 micron Filter, Viton Seal*
ADVCCO-50 Low Flow (10 sccm or less)
Calibration-Control Modules only F
ADVCCO-150 High Pressure Calibration 69
* Buna-N® or Kalrez® Seals available on special order.
GAS HANDLING EQUIPMENT
FLOW DEVICES
Gas Dilution System

Series 2020
The Series 2020 from Environics® is a computerized gas dilution
system that automatically generates precise gas standards for rapid
multi-point and multi-scale calibrations. The Series 2020 precisely
dilutes high concentration Protocol-1 or certified gas cylinders to an
infinitely variable range of concentrations from high percents to low
parts per million. The instrument meets or exceeds the performance
requirements of the United States EPA 40 CFR Part 51 Method 205
Appendix M.
The Series 2020 gas dilution system consists of a single chassis
supporting up to six (6) mass flow controllers, a serpentine pre-mix
zone and a zero dead-space final mixing zone. All gas wetted sur-
faces are electropolished stainless steel. Seals are gas compatible
elastomers. The Series 2020 employs mass flow controllers calibrated
www.praxair.com/specialtygases

to a NIST (National Institute of Standards and Technology) traceable


primary standard. Series 2020 Gas Dilution System

Features and Benefits


■ Broad range of dilution ratios ■ Automatic calculation of ■ High capacity memory ■ Allows user to add additional
(1:1 - 10,000:1) allows user dilution and span gas flows permits storage and recall of gas circuits, reducing initial
to reduce the number of gas eliminates the need for up to 200 multi-component investment and protecting
cylinders needed to perform manual computation and “recipes” saving time and against obselence
compliance tests allows rapid transition from reducing errors ■ Optional RS-232 Serial Data
■ Broad dilution ratio capability point to point and scale to ■ Twenty-five line by eighty Interface permits remote
allows calibration of most scale character display permits operation and complete
analyzer ranges from one ■ Internally-stored mass flow viewing of data in integration with a data
cylinder of each gas specie controller calibration data worksheet form station
reducing gas costs, transport improves accuracy
and handling labor

1-877-PRAXAIR

Software Specifications Performance and Mechanical Specifications


■ Concentration Mode ■ Divider Mode ■ Accuracy ■ Performance Temperature
User enters target output Allows the user to Concentration ± 1.0% 59 oF to 95 oF
gas concentration for the operate the instrument of set point (15 oC to 35 oC)
span gas. The actual as a computerized ten Flow ± 1.0% of set point ■ Operating Temperature
concentration is displayed step gas divider ■ Repeatability 32 oF to 122 oF
during mixing ■ Automatic Sequencer ± 0.05% of set point (0 oC to 50 oC)
■ Flow Mode Permits unattended ■ Warm Up Time ■ Dimensions
User enters target flow rate automatic operation of 30 minutes 17" W x 7" H x 24" D
(cc’s per minute) for each the instrument on a (43 cm x 18 cm x 61 cm)
component gas. Actual flow programmable ■ Operating Performance
rates are displayed after seven-day schedule Minimum: ■ Weight
mixing is initiated 10 psig (0.67 Bar) 35 lb (16 kg)
■ Purge Mode Recommended:
■ Maintain Ports Purge component gas 25 psig (1.68 Bar)
User enters the name of circuits and mixing zone Maximum:
the component gas in the ■ Status (Optional) 75 psig (5.04 Bar)
source cylinder, its con- Allows user to remotely
centration and the port to activate different modes
which it is connected of the system and also
activate external devices

Ordering Information Options


ENI2020 2020 Series Gas Dilution System ■ Serial/Parallel Port Interface ■ Purge System
■ Status Board ■ Solenoid Valve on Output
■ Additional Gas Circuits, ■ Rack Mountable Case
Component or Dilution ■ Heated Flow Path

F
70
GAS HANDLING EQUIPMENT
FLOW DEVICES
Gas Blending Systems

Series 2000
The Series 2000 computerized multi-component gas blender from
Environics® automatically mixes gases to generate precise gas cali-
bration standards, creating gaseous atmospheres or producing gas
mixtures for analytical research or production purposes. The Series
2000 dynamically produces complex mixes containing up to eight (8)
individual component gases in a balance gas. Each component con-
centration may be independently varied in response to user com-
mands. The Series 2000 can produce gas concentrations from per-
cent levels to ppb for single or multi-point calibration of gas chroma-
graphs, process gas analyzers, mass spectrometers, FTIR’s and
other gas analytical devices.
The Series 2000 gas blender consists of a single chassis supporting
up to nine (9) mass flow controllers, a serpentine pre-mix zone and

1-877-PRAXAIR
a zero dead-space final mixing zone. All gas wetted surfaces are
electropolished 316 stainless steel. Seals are gas compatible elasto-
mers. The Series 2000 employs mass flow controllers calibrated to Series 2000 Gas Blender
a NIST traceable primary standard.

Features and Benefits


■ Simultaneous 8 component ■ Automatic calculation of ■ High capacity memory ■ Modular design allows user


dynamic mixing permits the dilution and span gas flows permits storage and recall to add additional gas circuits
user to generate a wide eliminates need for manual of many muti-component at a later time, reducing initial

www.praxair.com/specialtygases
range of complex standards computation and allows for receipes, saving time and investment and protecting
with a minimum inventory of rapid transition from point to reducing errors against obsolescence
multi-component cylinders point and scale to scale ■ Twenty-five line by eighty ■ Optional RS-232 Serial Data
■ Internally stored mass flow character display permits Interface permits remote
controller calibration data viewing of data in worksheet operation and complete
improves accuracy form integration with a data station

Software Specifications Performance and Mechanical Specifications


■ Concentration Mode ■ Purge Mode (Optimal) ■ Accuracy ■ Performance Temperature
User enters target output Purge component gas Concentration ± 1.0% 59 oF to 95 oF
gas concentration (ppm circuits and mixing zone of set point (15 oC to 35 oC)
or %) for each component ■ Flow Mode Flow ± 1.0% of set point ■ Operating Temperature
■ Automatic Sequencer User enters target flow rate ■ Repeatability 32 oF to 120 oF
Permits unattended automatic (cc’s per minute) for each ± 0.05% of set point (0 oC to 50 oC)
operation of the instrument on component gas. Actual flow ■ Warm Up Time ■ Dimensions
a programmable seven-day rates are displayed after 30 minutes 17" W x 7" H x 24" D
schedule mixing is initiated (43 cm x 18 cm x 61 cm)
■ Operating Performance
■ Maintain Ports ■ Status (Optional) Minimum: ■ Weight
User enters the name of the Allows user to remotely 10 psig (0.67 Bar) 35 lb (16 kg)
component gas in the source activate different modes Recommended:
cylinder, its concentration of the system and also 25 psig (1.68 Bar)
(ppm or %) and the port to activate external devices Maximum:
which it is connected 150 psig (9.87 Bar)
75 psig (5.04 Bar) with
Purge Option

Ordering Information Optional Equipment


ENI2000 2000 Series Gas Blender ■ Serial/Parallel Port Interface ■ Solenoid Valve on Output
■ Status Board ■ Ozone Generator
■ Extra Component Gas Port (0.0 to 1.0 ppm)
■ Purge System ■ Heated Flow Path
■ Permeation Oven

F
71
GAS HANDLING EQUIPMENT
GAS GENERATORS
Praxair’s HyLab™ Hydrogen Generators

Praxair’s HyLab™ hydrogen generators are in the field. Hydrogen gas is produced by
an excellent source of ultra pure, dry hy- electrolytic dissociation of water.
drogen for a wide range of laboratory uses.
Praxair model HyLab 90 is designed to sup-
The generators are used extensively with
ply hydrogen as a fuel gas for flame ioniza-
gas chromatographs, as a feed gas for
tion detectors at a purity of 99.9995%. This
flame ionization detectors (FID), as a re-
model utilizes a proton exchange membrane
action gas for hall detectors, and as a
to produce hydrogen at pressures of up
carrier gas to ensure absolute repeatability
to 100 psig.
of retention times. In high sensitivity trace
hydrocarbon analyzers and air pollution Praxair models HyLab 150, 300, 500, 800
monitors, the hydrogen produced ensures and 1200 utilize palladium membranes to
the lowest possible background noise. ensure high-purity hydrogen. Only hydrogen
Other applications include using hydrogen and its isotopes can penetrate the palladium Praxair’s HyLab™ 150/300 (left) and
for hydrogenation reactions and for FIDs membrane; therefore, the purity of the out- HyLab™ 90 (right) Hydrogen Generators
used in the analysis of engine gas emiss- put gas is guaranteed to be 99.99999+%
www.praxair.com/specialtygases

ions in the automobile industry. consistently. This technology produces hy-


drogen at a purity two orders of magnitude
In all applications Praxair’s HyLab genera-
greater than other technologies. The HyLab
tors set the standard for safety, operational
800 and 1200 generate up to 100 psig;
performance, and dependability.
ideal for use as a carrier gas for fast GC
The HyLab generators eliminate the need applications.
for high pressure cylinders of hydrogen in
Praxair hydrogen generators offer many
the laboratory. It is no longer necessary to
special features to ensure safe and conven-
interrupt important analysis to change cy-
ient operation. These features include low-
linders. Generator flow capacities of up to
water audible alarms to indicate when the
1200 cc/min. of ultra-high purity hydrogen
water reservoir needs filling and automatic Praxair’s HyLab™ 500/800/1200
are available. They are compact bench top
shutdown to protect expensive laboratory Hydrogen Generators
units designed for use in the laboratory or
equipment.

Features and Benefits


■ Produce a continuous supply of pure ■ Easy annual maintenance ■ Safe, simple 10-minute maintenance
hydrogen gas, ideal for carrier and fuel ■ Certified for laboratory use by procedure is required each year
1-877-PRAXAIR

gas applications CSA, UL, IEC 1010, and CE ■ Complies with OSHA regulations
■ Compact and reliable – only one square ■ Only deionized water and standard 1910.103 by eliminating hydrogen
foot of bench space required electrical service are required for cylinder storage
■ Designed to run continuously continuous operation ■ Automatic over-pressure shutdown
24 hours/day ■ Regulated pressure: ■ Minimal volume of stored hydrogen
■ LED displays and gages indicate system 0 to 60 psig under pressure at any time (eliminates
status at a glance (models HyLab 150 and 300); explosion hazard)
■ Safe – produces only as much gas as 0-100 psig ■ Status indicators with alarms and
you need (models HyLab 90, 500, 800 and 1200) automatic shutdown for safe,
continuous operation

Specifications
■ Hydrogen Purity ■ Maximum Hydrogen Flow Rate ■ Dimensions
HyLab 90 99.9995+% HyLab 90 90 cc/min HyLab 90: 14.5" W x 14" D x 13" H
HyLab 150/300/ 99.99999+% HyLab 150 150 cc/min (37 cm x 36 cm x 33 cm)
500/800/1200 HyLab 300 300 cc/min HyLab 150/300: 12" W x 13" D x 23" H
■ Hydrogen Outlet Pressure HyLab 500 500 cc/min (31 cm x 32 cm x 57 cm)
HyLab 150/300 Adjustable 0-60 psig HyLab 800 800 cc/min HyLab 500/800/1200:
HyLab 90/500/ Adjustable 1-100 psig HyLab 1200 1200 cc/min 13" W x 17" D x 14.5" H
800/1200 ■ Electrical Requirements (33 cm x 44 cm x 37 cm)
120 vac/60 hz (220 V/50 hz available) ■ Shipping Weight
■ Certifications HyLab 90 40 lb (18 kg)
IEC 1010-1; CSA 1010; UL 3101 HyLab 150/300 50 lb (26 kg)
HyLab 500/800/1200 45 lb (20 kg)

Ordering Information
Part Number Description Part Number Description Part Number Description
F GNTHYLAB90 HyLab 90 hydrogen generator GNTHYLAB300 HyLab 300 hydrogen generator GNTHYLAB800 HyLab 800 hydrogen generator
72 GNTHYLAB150 HyLab 150 hydrogengenerator GNTHYLAB500 HyLab 500 hydrogen generator GNTHYLAB1200 HyLab 1200 hydrogen generator
GAS HANDLING EQUIPMENT
GAS GENERATORS
Praxair’s AirLab™ Zero Air Generators

Convenient
Praxair’s AirLab™ zero air generators are
complete systems with state-of-the-art,
highly reliable components engineered for
easy installation, operation and long-term
performance. Praxair zero air generators
are easy to install. All that is required is a
standard compressed air line and an
electrical outlet.
Easy to Operate
The AirLab™ zero air generators from Praxair
are easy to operate, there is no complicated
operating procedure to learn or any labor
intensive monitoring required.

1-877-PRAXAIR
Praxair’s Airlab™ 1 Praxair’s Airlab™ 3.5/7/18/30
Cost Effective Zero Air Generator Zero Air Generators
The AirLab™ zero air generators offer long
term cost stability.

Features and Benefits


■ Reliable Praxair zero air grade from ■ Models available to service up to 900 FID* ■ Compact design frees up valuable
house compressed air AirLab 1 Up to 3 laboratory floor space – wall or


■ Increases the accuracy of analysis and AirLab 3.5 Up to 11 bench mountable; AirLab 140/280
AirLab 7 Up to 23 are floor models

www.praxair.com/specialtygases
reduces the cleaning requirement of the
detector AirLab 18 Up to 60 ■ Operates at low pressures,
AirLab 30 Up to 100 from 40 to 125 psig
■ Recommended and used by many
GC and column manufacturers AirLab 140 Up to 450 ■ Silent operation and minimal operator
AirLab 280 Up to 900
■ Cost effective for higher volume users attention required
* Based on 300 ccm fuel air rate
■ High purity zero air generator helps ■ High flow models available for
■ Eliminates the need to recalibrate
ensure a consistently flat baseline demanding CEM and VEM applications
instruments after replacing empty
cylinders of gas

Specifications
■ Maximum Zero Air Flow Rate ■ Maximum Inlet Hydrocarbon Concentration ■ Electrical Requirements
AirLab 1 1.0 Lpm (as methane) 120 vac/60Hz
AirLab 3.5 3.5 Lpm 100 ppm ■ Dimensions
AirLab 7 7.0 Lpm ■ Pressure Drop at Max Flow Rate AirLab 1: 10" W x 3" D x 12" H
AirLab 18 18 Lpm 4 psig (AirLab 1/3.5/7/18/30) (25 cm x 8 cm x 30 cm)
AirLab 30 30 Lpm 10 psig (AirLab 140/280) AirLab 3.5/7/18/30: 11" W x 13" D x 16" H
AirLab 140 140 Lpm (27 cm x 34 cm x 42 cm)
AirLab 280 280 Lpm ■ Maximum Inlet Air Temperature
78 oF (25 oC) AirLab 140/280: 25" W x 25" D x 41" H
■ Outlet Hydrocarbon Concentration (64 cm x 64 cm x 104 cm)
(as methane) ■ Inlet/Outlet Ports
1/4" FPT ■ Shipping Weight
<0.05 ppm AirLab 1 7 lb (3 kg)
■ Minimum/Maximum Inlet Air Pressure ■ Start-Up Time for Specified Hydrocarbon AirLab 3.5/7/18/30 41 lb (19 kg)
40 psig/125 psig Concentration (as methane) AirLab 140/280 210 lb (96 kg)
45 minutes

Ordering Information
Part Number Description Part Number Description Part Number Description
GNTAIRLAB1 AirLab 1 zero air generator GNTAIRLAB18 AirLab 18 zero air generator GNTAIRLAB140 AirLab 140 zero air generator
GNTAIRLAB3.5 AirLab 3.5 zero air generator GNTAIRLAB30 AirLab 30 zero air generator GNTAIRLAB280 AirLab 280 zero air generator
GNTAIRLAB7 AirLab 7 zero air generator

Please see information on


Scroll Air Compressors,
page F78 F
73
GAS HANDLING EQUIPMENT
GAS GENERATORS
Praxair’s NitroLab™ Nitrogen Generators

Praxair’s NitroLab ™ nitrogen generators are The generation process for Praxair’s
engineered and packaged in a small cabinet NitroLab generators consist of two stages.
to fit nearly any laboratory. The NitroLab The first stage is the oxidation of hydrocar-
76-94 and NitroLab PSA generators from bons from the inlet air supply to 0.1 ppm.
Praxair can produce up to 12 lpm of ultra The second stage is the removal of CO2, O 2
high purity nitrogen gas. These systems are and water vapor by pressure swing absor-
completely engineered to transform stan- ption to less than 1 ppm. The generators
dard compressed air at 99.9995% nitrogen. also have high efficiency coalescing pre-
Nitrogen is produced utilizing a combination filters and a 0.01 micron (absolute) mem-
of state-of-the-art purification technologies brane filter incorporated into its design.
and high efficiency filtration. Praxair’s
NitroLab™ 76-94
Nitrogen Generator
www.praxair.com/specialtygases

Typical Applications Specifications


■ General laboratory nitrogen gas supply Model NitroLab 76-94 NitroLab PSA
■ Carrier gas to GC columns ■ Maximum Nitrogen Flow Rate See Flow Table See Flow Table
■ Use with packed column instruments ■ Nitrogen Purity 99.9995% 99.9995% to 99.9999%
■ Ideal for continuous purge of ■ Maximum Nitrogen Output Pressure See Flow Table See Flow Table
ICP Spectrometers ■ CO Concentration <1.0 ppm <1.0 ppm
■ CO2 Concentration <1 ppm <1 ppm
Features and Benefits ■ O2 Concentration <1 ppm <1 ppm
■ Produces a continuous supply of ■ H2O Concentration <2 ppm <2 ppm
high purity nitrogen gas from existing ■ Hydrocarbon Concentration <0.1 ppm <0.1 ppm
compressed air ■ Argon Concentration 0.9% 0.9%
■ Compact design frees up floor space ■ Minimum/Maximum Inlet Pressure 60 psig/125 psig 60 psig/125 psig
■ Offers long term cost stability ■ Recommended Inlet Temperature <78 oF (25 oC) <78 oF (25 oC)

Ideal for carrier gas or solvent o o


■ Ambient Operating Tempurature 60 F to 100 F 60 oF to 100 oF
evaporation applications
1-877-PRAXAIR

(16 to 38 oC) (16 to 38 oC)


■ Install it once – uses compressed air
■ Maximum Air Consumption 42 lpm (1.5 scfm) 84 lpm (3.0 scfm)
and one 120 VAC/60 Hz outlet
■ Inlet Connection 1/4" FPT 1/4" FPT
■ Safe, reliable, low maintenance
■ Outlet Connection 1/8" Compression 1/4" FPT
■ Cost effective for applications
demanding high purity nitrogen ■ Electrical Requirements 120 vac/60 Hz 120 vac/60 Hz
■ Power Consumption 700 watts 1100 watts
■ Dimensions 12" W x 16" D x 35" H 25" W x 25" D x 41" H
30 cm x 41 cm x 89 cm) (64 cm x 64 cm x 104 cm)
■ Shipping Weight 115 lb (52 kg) 500 lb (227 kg)

Flow Table: NitroLab 76-94 Flow Table: NitroLab PSA


Inlet Air Maximum Maximum Inlet Air Pressure Maximum Outlet Flow Maximum Outlet Pressure
Pressure Outlet Flow Outlet Pressure (psig) (lpm) (psig)
(psig) (lpm) (psig) Outlet Purity 99.9999% 99.9995% 99.9999% 99.9995%
125 1.1 85 125 5 12 83 60
110 1.0 75 110 5 12 73 55
100 0.9 65 100 5 12 63 45
90 0.8 60 90 4 10 62 45
80 0.7 50 80 4 8 51 40
70 0.6 45 70 2 8 50 35
60 0.5 35 60 2 6 42 33

Ordering Information Please see information on


F Part Number Description Scroll Air Compressors,
74 GNTNITROLAB76-94 NitroLab 76-94 nitrogen generator page F78
GNTNITROLABPSA NitroLab PSA nitrogen generator
GAS HANDLING EQUIPMENT
GAS GENERATORS
Membrane Nitrogen Supply System

The membrane nitrogen systems from The key to nitrogen production in the mem-
Praxair offer a reliable, on-site supply alter- brane system from Praxair is the technically
native to customers who use high-pressure advanced bundles of hollow-fiber mem-
cylinders, liquid containers or small bulk branes. The membranes separate nitrogen
systems. Compared to cylinder gas supply, from air by selective permeation. When air
Praxair’s membrane systems: passes through the membrane fibers, oxy-
gen, carbon dioxide and water vapor per-
■ Reduce nitrogen costs up to
meate rapidly and safely return to the atmo-
20% to 40%
sphere. Nitrogen, which does not readily
■ Reduce labor costs by eliminating
permeate the membrane, goes directly into
most cylinder changeouts
the distribution system and is supplied at
■ Increase productivity by eliminating
the customer’s flow rate, pressure and pur-
cylinder changeout
ity requirements. Systems operate by using
■ Reduce distribution costs
plant air or by incorporating a dedicated
■ Free-up space at your facility
feed air compressor. Praxair can supply de-

1-877-PRAXAIR
Praxair offers membrane systems in a var- dicated compressors that are integrated into
iety of sizes, capable of producing nitrogen the membrane system. Surge tanks are also
at purity and flow rates suitable for most available and can be incorporated into
small-volume needs. the system.
Please Note: Praxair’s membrane nitro-
gen systems must be operated in a well-
ventilated area and the by-product (oxygen
and other), must be properly vented.


www.praxair.com/specialtygases
Typical Applications Ordering Information
■ General lab nitrogen supply Part Number Flow rate with Flow rate with Flow rate with Dimensions Weight
■ LCMS instruments 70 psig feed air 110 psig feed air 165 psig feed air WxDxH lb (kg)
95.0% - 99.9% 95.0% - 99.9% 95.0% - 99.9% in (cm)
■ Plasma cutting systems
PRXIB100-G3 95% - 152 scfh 95% - 299 scfh 95% - 507 scfh 36 x 18 x 66 150
■ Food packaging/blanketing
98% - 74 scfh 98% - 151 scfh 98% - 261 scfh (91 x 46 x 168) (68)
■ Corrosive Liquid transfer
PRXIB200-G3 95% - 305 scfh 95% - 598 scfh 95% - 1016 scfh 36 x 18 x 66 175
■ Paint blanketing 98% - 149 scfh 98% - 303 scfh 98% - 523 scfh (91 x 46 x 168) (79)
■ Cabinet and vessel inerting and purging PRXIB300-G3 95% - 581 scfh 95% - 1140 scfh 95% - 1934 scfh 36 x 18 x 66 200
■ Oxidation Pervention 98% - 284 scfh 98% - 578 scfh 98% - 997 scfh (91 x 46 x 168) (90)
PRXIB300-G5 95% - 341 scfh 95% - 671 scfh 95% - 1137 scfh 36 x 18 x 66 200
98% - 186 scfh 98% - 372 scfh 98% - 633 scfh (91 x 46 x 168) (90)
Specifications
99% - 132 scfh 99% - 266 scfh 99% - 456 scfh
■ Nitrogen Purity 99.9% - 47 scfh 99.9% - 104 scfh 99.9% - 184 scfh
95%-99.9% PRXIB500-G3 95% - 1162 scfh 95% - 2281 scfh 95% - 3868 scfh 36 x 18 x 66 225
■ Water Content 98% - 569 scfh 98% - 1157 scfh 98% - 1994 scfh (91 x 46 x 168) (102)
< 10 ppm PRXIB500-G5 95% - 682 scfh 95% - 1340 scfh 95% - 2279 scfh 36 x 18 x 66 225
■ CO2 Content 98% - 373 scfh 98% - 742 scfh 98% - 1269 scfh (91 x 46 x 168) (102)
< 0.1 ppm 99% - 264 scfh 99% - 532 scfh 99% - 914 scfh
99.9% - 94 scfh 99.9% - 208 scfh 99.9% - 369 scfh
PRXIB750-G3 95% - 1744 scfh 95% - 3421 scfh 95% - 5807 scfh 32 x 72 x 66 1150
98% - 854 scfh 98% - 1735 scfh 98% - 2993 scfh (81 x 183 x 168) (522)
PRXIB750-G5 95% - 1024 scfh 95% - 2015 scfh 95% - 3419 scfh 32 x 72 x 66 1150
98% - 560 scfh 98% - 1115 scfh 98% - 1904 scfh (81 x 183 x 168) (522)
99% - 396 scfh 99% - 800 scfh 99% - 1372 scfh
99.9% - 141 scfh 99.9% - 312 scfh 99.9% - 554 scfh
PRXIB1000-G3 95% - 2325 scfh 95% - 4562 scfh 95% - 7743 scfh 32 x 72 x 66 1200
98% - 1139 scfh 98% - 2314 scfh 98% - 3991 scfh (81 x 183 x 168) (544)
PRXIB1000-G5 95% - 1365 scfh 95% - 2681 scfh 95% - 4559 scfh 32 x 72 x 66 1200
98% - 747 scfh 98% - 1485 scfh 98% - 2539 scfh (81 x 183 x 168) (544)
99% - 528 scfh 99% - 1064 scfh 99% - 1829 scfh
99.9% - 187 scfh 99.9% - 415 scfh 99.9% - 738 scfh
PRXIB1500-G3 95% - 2906 scfh 95% - 5703 scfh 95% - 9679 scfh 32 x 72 x 66 1250
98% - 1424 scfh 98% - 2892 scfh 98% - 4988 scfh (81 x 183 x 168) (566)
PRXIB1500-G5 95% - 1706 scfh 95% - 3358 scfh 95% - 5698 scfh 32 x 72 x 66 1250 F
98% - 934 scfh 98% - 1859 scfh 98% - 3174 scfh (81 x 183 x 168) (566)
99% - 660 scfh 99% - 1333 scfh 99% - 2287 scfh
75
99.9% - 234 scfh 99.9% - 520 scfh 99.9% - 923 scfh
GAS HANDLING EQUIPMENT
GAS GENERATORS
Membrane Nitrogen Module

Praxair’s membrane nitrogen module uses hollow fiber technology to separate


clean air into a concentrated nitrogen output stream and an oxygen rich waste
stream that is vented to atmosphere. Nitrogen purity ranging from 95.0% to
99.5% is available from the membrane. The membrane nitrogen module is in-
stalled in plant air piping systems minimizing overall space requirements. The
Membrane Nitrogen Module eliminates the need for high pressure and liquid
nitrogen cylinders. Perfect for point of use nitrogen requirements.

Typical Applications
■ Point of use nitrogen applications ■ Increases perishables shelf life
■ Cabinet and vessel inerting/purging ■ Used to run pneumatic tools
■ LCMS Instrumentation ■ Vessel and equipment blanketing
■ Oxidation prevention ■ Create inert atmospheres
www.praxair.com/specialtygases

■ Laboratory nitrogen supply ■ Electronic component storage

Features and Benefits


■ Low operating cost with no ■ Silent operation
electricity required ■ Simple installation, mounting
■ In-line installation brackets included
■ Wall mounted; no floor space required ■ Dual coalescing filters included
■ Wide range of purities available ■ Eliminates cylinder change
■ Explosion proof outs and handling
■ No moving parts or motors ■ Long term cost stability

Ordering Information and Flow Rates – Measured in Standard Cubic Feet per Hour (scfh)

Part Number 145 psig inlet pressure 100 psig inlet pressure 80 psig inlet pressure
1-877-PRAXAIR

95.0% 97.0% 99.0% 99.5% 95.0% 97.0% 99.0% 99.5% 95.0% 97.0% 99.0% 99.5%
IMBTN200X 19.6 13.0 6.6 4.6 11.6 7.6 3.6 2.5 8.3 5.4 2.6 1.7
IMBTN210X 29.5 19.8 10.1 7.2 17.7 11.7 5.6 4.0 12.7 8.3 4.1 2.7
IMBTN220X 40.5 27.4 14.3 9.5 24.6 16.4 8.2 5.9 17.9 11.8 5.8 4.1
IMBTN300X 59.2 40.1 21.0 14.2 35.9 24.0 12.1 8.4 26.1 17.3 8.9 5.9
IMBTN310X 94.7 64.1 33.5 22.8 57.5 38.4 19.3 13.7 41.8 27.7 14.2 9.5
IMBTN400X 132.4 89.7 46.9 33.7 80.3 53.8 27.0 19.0 58.4 38.7 19.8 13.2
IMBTN500X 378.4 256.1 133.5 94.9 229.6 153.5 76.7 55.0 166.8 110.4 56.7 38.3
IMBTN510X 474.2 320.8 166.7 119.7 287.7 192.2 95.6 70.1 209.1 138.3 67.8 48.7

Replacement Equipment Note – above flow rates based on:


■ Inlet compressed air at 85 °F
Part Dimensions Approx. Port Membrane Annual Maintenance Kit* ■ Maximum operating pressure is 200 psig
Number LxW Weight Size Replacement Part Number ■ Coalescing pre-filters are included and
Cartridge come with differential pressure indicators
IMBTN200X 19" x 12" 7 lb 3/8" IMBTN200 HNKHFMK73-12M ■ Port availability NPT for BSP, add B to

IMBTN210X 27" x 12" 8 lb 3/8" IMBTN210 HNKHFMK73-12M model number (eg. IMBTN210XB)
■ Dimensions and weight are calculated with
IMBTN220X 35" x 12" 9 lb 1/2" IMBTN220 HNKHFMK73-12M two filters attached to the module
IMBTN300X 20" x 16" 11 lb 3/4" IMBTN300 HNKHFMK73-12M
IMBTN310X 27" x 16" 14 lb 3/4" IMBTN310 HNKHFMK73-12M
IMBTN400X 29" x 17" 17 lb 1" IMBTN400 HNKHFMK73-12M
Please see information on
IMBTN500X 35" x 19" 19 lb 1" IMBTN500 HNKHFMK73-24M
Scroll Air Compressors,
IMBTN510X 41" x 19" 38 lb 1" IMBTN510 HNKHFMK73-24M page F78
* Annual Maintenance Kit includes:
F ■ 4 replacement coalescing elements
76 ■ 2 replacement automatic drains
■ 2 bowl o-rings
GAS HANDLING EQUIPMENT
GAS GENERATORS
Generator Back-Up System

Praxair’s generator back-up system is now available in a complete


package, ready for installation. Back-Up systems are available for air,
hydrogen and nitrogen analytical gas generators. These systems are
To Analyzer From Generator
designed to meet the highest safety and quality standards necessary



to safeguard instruments against unexpected supply interruption.

These systems control pressure, prevent back flow, and maintain high
purity gas standards so critical in today’s laboratory environment. All
components including regulators, flex hoses, valves and fittings meet
instrumentation gas specifications.

Features and Benefits


■ Eliminates unscheduled down time, high purity gas
is continuously supplied to the laboratory

1-877-PRAXAIR
■ Praxair generators may be serviced or cylinders changed
out without interrupting gas supply
■ The system is designed and the components selected
for high purity laboratory applications.
■ Back-up cylinder pressure control is achieved through
differential pressure principle.


Specifications Materials

www.praxair.com/specialtygases
■ Maximum Inlet Pressure ■ Outlet Delivery Pressure Range ■ Regulator ■ Diaphragm Valves
3000 psig Pressure regulator: Body: Brass/316L SS Body: Brass/316L SS
■ Operating Temperature 0-100 psig Diaphragm: 316L Diaphragm: 316L SS
-20 oF to +160 oF ■ Pigtail Length Internal seals: PTFE Teflon Seat: Metal to metal
(-29 oC to +71 oC) 3 Feet Seat: PTFE Teflon ■ Mounting Panel
Filter: 10 micron multilayer, Stainless steel
■ Inlet/0utlet Connections ■ Panel Size sintered 316L stainless steel
CGA connection and 10" W X 11" H wire mesh (patented) ■ Weight
1/4" compression fitting. (25.4 cm X 28 cm) 8 lb (3.6 kg)
Optional 1/8" compression ■ Check Valves
fittings are available Body: Brass/316L SS
Seal: Viton

Ordering Information – Series CON5GBABCDEF


A B C D E F
Material Inlet Gauge No. of Regulators Pigtail Type Reserve / Remote Inlet Outlet
B: Brass 3: 4000 psi 0: (200 psi outlet gauge only) 1: 36" 0: none (for reg qty 1) 0: 1/4" tube
S: Stainless 5: 1000 psi 1: (150 psi reg with 200 psi gauge) 2: 72" A: Air CGA 590 1: 1/8" tube
Steel 6: 300 psi H: Hydrogen CGA 350 2: 1/4" FPT
7: 700 psi N: Nitrogen CGA 580 3: 1/4" MPT

F
77
GAS HANDLING EQUIPMENT
GAS GENERATORS
Scroll Air Compressors

SF Series
The SF Series is the latest innovation in small rotary compressor
technology. The lubrication-free compression chamber eliminates
the possibility of any oil carryover into the compressed air. Available
from 3 to 20 HP, the SF Series is designed for extremely quiet and
continuous 24-hour operation. To further simplify installations, full
feature models, which include an integrated refrigerated dryer, are
available. The configuration is totally pre-piped and wired for easy
and economical installation.

Features and Benefits


■ 100% Oil Free Air
■ Air Cooled, Fully Packaged
www.praxair.com/specialtygases

■ Single Stage
■ High Efficiency
■ Whisper Quiet Operation
■ 24-hour Continuous Duty Application

Specifications
Model Air Receiver Tank Motor Capacity (acfm) (1) Sound Level Net Weight (lb/kg)
(not included HP 100 125 150 (dBa) (2) Block Pack FF
SF2 30 gallon 3 9.0 6.8 6.0 58 35/15.4 221/100 260/118
SF4 60 gallon 5 14.7 10.5 9.1 59 46/20.9 249/113 289/13
SF6 120 gallon 8 22.9 15.8 13.4 57 N/A 986/448 1052/478
SF8 120 gallon 10 27.9 21.1 17.6 57 N/A 1014/461 1060/481
SF11 120 gallon 15 41.6 31.5 26.6 60 N/A 1147/521 1213/551
SF15 120 gallon 20 54.4 42.3 34.8 63 N/A 1279/581 N/A

(1)
Unit performance measured according to Pneurop/CAGIPN2CPTC2
1-877-PRAXAIR

(2)
Maximum noise level measured at a distance of 3 ft. according to Pneurop/CAGIPN8NTC2 test code

Ordering Information – ATAABCDE


A B C D E
Model Pressure Voltage Phase Configuration
1: SF2 1: 100 psig 1: 200 V 1: 1ø 1: Pack
2: SF4 2: 125 psig 2: 230 V 2: 3ø 2: Full Feature
3: SF6 3: 150 psig 3: 460 V
4: SF8 4: 575 V
5: SF11
6: SF15

Optional Equipment
Part Number Description
ATA1310256111 30 gallon epoxi-coated interior air receiver tank Please see Praxair’s
with accessories air and nitrogen
ATA1310256112 60 gallon epoxi-coated interior air receiver tank generators,
with accessories pages F73 to F76
ATA1310256363 120 gallon epoxi-coated interior air receiver tank
with accessories

F
78
GAS HANDLING EQUIPMENT
GAS GENERATORS
Membrane Air Dryers

Praxair’s membrane air dryers use hollow fiber technology to remove water vapor from
compressed air streams. Dewpoints of -40 oF are available. Nine modules are available
with a wide range of flow rates. (See Ordering Information below). The membrane air
dryers are combined with coalescing filters for superior filtration and drying.

Typical Applications
■ Low dewpoint instrument air ■ General laboratory air supply
■ Pneumatic equipment ■ Air for air bearings
■ Pressurizing electronic cabinets ■ Air for electrostatic painting
■ Analytical instrumentation ■ Ozone generators
■ Prevention of freeze ups ■ Dental air
■ Dry air for hazardous areas ■ Air for air brakes

1-877-PRAXAIR
Features and Benefits
■ Low operating cost with no ■ Selective Purge Available
electricity required For larger quantity orders Praxair offers
■ Environmentally sound, no refrigerants selective purge. Praxair will install purge
or freon equipment within the membrane dryer
■ Wide range of dewpoints available sized in a way to most closely match
your feed air availability and dry air
■ Explosion proof


needs. Please contact Praxair for
■ No moving parts or motors more details

www.praxair.com/specialtygases
■ Silent operation
■ No desiccant changes required
■ Dual coalescing filters included
■ Includes mounting bracket

Ordering Information and Specifications – Membrane Air Dryers


Part Number Flow Rate (scfm) Flow Rate (scfm) Dimensions Weight Port Size Replacement
Inlet/Outlet Inlet/Outlet LxW Cartridge
40 oF Dewpoint -40 oF Dewpoint Part Number
HNKTD200X 1.15/0.94 0.38/0.16 11" x 12" 7 lb 3/8" HNKTD200
HNKTD210X 3.56/2.99 1.51/0.94 15" x 12" 8 lb 3/8" HNKTD210
HNKTD220X 7.84/6.43 3.72/1.86 19" x 12" 9 lb 1/2" HNKTD220
HNKTD230X 10.5/8.7 4.7/2.8 27" x 12" 11 lb 1/2" HNKTD230
HNKTD300X 19.4/16.1 8.3/5.0 20" x 16" 14 lb 3/4" HNKTD300
HNKTD310X 30.4/25.1 13.4/8.0 27" x 16" 17 lb 3/4" HNKTD310
HNKTD400X 57.2/47.1 24.6/14.5 29" x 17" 19 lb 1" HNKTD400
HNKTD500X 85.9/71.8 40.0/25.8 35" x 19" 38 lb 1" HNKTD500
HNKTD510X 112.0/91.8 52.0/32.2 41" x 19" 44 lb 1" HNKTD510
Notes assume the following:
o
■ Inlet compressed air of 100 psig and 100 F dewpoint. Conforms to CAGI Standard ADF 700
o
■ Maximum operating pressure is 200 psig. Maximum inlet temperature is 150 F
■ Port availability NPT for BSP, add B to part number (eg. HNKTD210XB)

Ordering Information – Annual Maintenance Kit*


Models Part Number
HNKTD200X through HNKTD230X HNKHFMK73-12M
HNKTD300X through HNKTD400X HNKHFMK73-24M
HNKTD500X through HNKTD510X HNKHFMK73-28M
* Annual Maintenance Kit includes:
■ 4 replacement coalescing elements
■ 2 replacement automatic drains F
■ 2 bowl o-rings
79
GAS HANDLING EQUIPMENT
GAS GENERATORS
Coalescing Filter Assemblies

Modular Ultra Filter Systems


Choose one or more of these modular filters to create your
own high-pressure/high-flow filtration system, based on
your lubricated or unlubricated compressed air needs.

Typical Applications
■ General Purpose Applications such as Plant Compressed Air
Single stage filtration. Use a particulate filter
■ Instrument Air and other Critical Air Requirements
Two stage filtration is necessary. Use aparticulate filter
and oil removal filters
■ Removal of Trace Compressor Oil Vapor
Use a particulate, oil removal filter and an oil vapor removal filter
www.praxair.com/specialtygases

Features and Benefits


■ All sizes up to 1-1/2" have a sight glass
■ ISO Standard 8573-1 for compressed air quality standards
■ Connections are NPT female
■ Metal bowls
■ Automatic float drain
■ Differential pressure indicates required filter change
■ Maximum pressure is 250 psig; temperature is 150 oF
Please see Praxair’s
■ Particulate filter separates water downstream of aftercoolers,
NEW membrane air dryers
rated to 3 microns
(page F79) and membrane
■ Oil removal coalescing filter creates oil-free air. nitrogen modules
Rated to 0.01 micron (page F76)
■ Oil vapor removal filter is used for food, drug and other

applications requiring removal of oil vapors and odors.


Rated to 0.003 ppm
1-877-PRAXAIR

■ Connector block kit lets you easily connect and disconnect


modular components for fast installation and maintenance

Specifications and Ordering Information


Particulate Oil Removal Oil Vapor
Filters Coalescing Filters Removal Filters
Pipe Maximum Overall Size Part Number Replacement Part Number Replacement Part Number Replacement
Size scfh HxW Part Number Part Number Part Number
1/4" 35 1-13/16" x 4-1/8" HNKPF7-12-3DGL HNKE7-12 HNKPF5-12-3DGL HNKE5-12 HNKPF1-12-3 HNKE1-12
3/8" 35 1-13/16" x 4-1/8" HNKPF7-16-3DGL HNKE7-16 HNKPF5-16-3DGL HNKE5-16 HNKPF1-16-3 HNKE1-16
1/2" 60 13-15/16" x 4-1/8" HNKPF7-20-4DGL HNKE7-20 HNKPF5-20-4DGL HNKE5-20 HNKPF1-20-4 HNKE1-20
3/4" 100 15-3/8" x 5-1/4" HNKPF7-24-6DGL HNKE7-24 HNKPF5-24-6DGL HNKE5-24 HNKPF1-24-6 HNKE1-24
1" 170 19-5/8" x 5-1/4" HNKPF7-28-8DGL HNKE7-28 HNKPF5-28-8DGL HNKE5-28 HNKPF1-28-8 HNKE1-28
1-1/4" 250 22-3/16" x 6-7/16" HNKPF7-32-8DGL HNKE7-32 HNKPF5-32-8DGL HNKE5-32 HNKPF1-32-8 HNKE1-32
1-1/2" 375 22-5/16" x 6-7/16" HNKPF7-36-12DGL HNKE7-36 HNKPF5-36-12DGL HNKE5-36 HNKPF1-36-12 HNKE1-36
2" 485 31" x 7-5/8" HNKPF7-40-16DGL HNKE7-40 HNKPF5-40-16DGL HNKE5-40 HNKPF1-40-16 HNKE1-40
2-1/2" 780 42-7/8" x 7-5/8" HNKPF7-48-20DGL HNKE7-48 HNKPF5-48-20DGL HNKE5-48 HNKPF1-48-20 HNKE1-48

F
80
GAS HANDLING EQUIPMENT
PURIFIERS/FILTERS
Stainless Steel In-Line Filters

High Pressure, High Purity, Stainless Steel In-Line Filters


Models SG6112, SG6113, SG6114
These in-line filters have a pleated wire mesh element which is easily
cleaned by flushing the filter in the opposite direction to normal flow.
Flow may be in either direction. All metal welded construction makes
these filters ideal for use in high purity and ultra high purity gas systems. SG6112/13 Filter SG6114 Filter

Specifications
■ Maximum Operating Pressure ■ Pressure Drop (to atmosphere) ■ Pressure Drop (to atmosphere) ■ Dimensions
6000 psig SG6112: SG6113 and SG6114: SG6112 and SG6113:
■ Operating Temperature Range 10 psi at 156 slpm Air 10 psi at 140 slpm Air 1-3⁄4" x 1" hex
-320 °F to +900 °F 50 psi at 433 slpm Air 50 psi at 389 slpm Air SG6114: 2-1⁄32" x 1" hex
■ Maximum Differential Pressure 100 psi at 768 slpm Air 100 psi at 691 slpm Air ■ Approximate Weight
100 psi 4 oz

1-877-PRAXAIR
Materials Ordering Information
■ Body ■ Pleated Mesh Element Part Number Inlet and Outlet Connections* Nominal Filtration Rating
Type 316 Stainless Steel SG6112: Type 316 Stainless Steel ADVSG6112 1⁄4" MPT by 1⁄4" FPT 15 micron
■ Retainer Screens SG6113 and SG6114: ADVSG6113 1⁄4" MPT by 1⁄4" FPT 2 micron
Type 316 Stainless Steel Type 304 Stainless Steel ADVSG6114 1⁄4" male VCR® (both ends) 2 micron

Brass In-Line Filters


www.praxair.com/specialtygases
High Pressure, Brass In-Line Filters (Models SG6120, SG6121, SG6122)
These in-line filters feature a sintered 316 stainless steel element which is easily re- SG6120
moved for cleaning or replacement making these filters convenient for use upstream of Filter
pressure regulators. These filters will protect a regulator from particulate contamination
which can build up and eventually cause seat leakage and regulator failure.

Specifications Materials
■ Maximum Operating Pressure ■ Dimensions ■ Connections ■ Body: Brass
3000 psig 2-1/4" x 3⁄4" hex 1/4" FPT (in) x ■ Spring, Element and Gasket
■ Operating Temperature Range ■ Approximate Weight 1/4" FPT (out) Type 316 Stainless Steel
-15 °F to + 400 °F 3 oz ■ Seal: Viton®

Ordering Information Optional Equipment – Replacement Element (Includes Seal and Spring)
Part Number Nominal Filtration Rating Part Number Description
ADVSG6120 10 micron ADVSG6120R 10 micron
ADVSG6121 5 micron ADVSG6121R 5 micron
ADVSG6122 1 micron ADVSG6122R 1 micron

Low Flow, In-Line Filters

Low flow, 2-Micron, In-Line Filters


(Models FM4741, FM4746)
Models FM4741 and FM4746 in-line filters feature a sintered stainless FM4741 Filter
steel element with a 2 micron filtration rating. The element is easily
removed for cleaning. Model FM4741, with an aluminum housing, is
designed for non-corrosive gas service. The FM4746, with a Type 316
stainless steel housing, is suitable for corrosive service. The 1⁄8" NPT
inlet and outlet connections make these filters convenient for use in
conjunction with many of Praxair’s variable area flowmeters.

Specifications Materials Ordering Information


■ Filtration Rating ■ Filter Element Maximum Operating
2 micron Type 316 Stainless Steel Part Number Body Pressure at 70 °F Temperature
■ Dimensions ■ Spring F
ADVFM4741 Aluminum 3500 psig 180 oF
2-13/32" x 1/2" hex Type 302 Stainless Steel 81
■ Approximate Weight ■ Seals ADVFM4746 Type 316 Stainless Steel 5000 psig 350 oF
1.5 oz Viton ®
GAS HANDLING EQUIPMENT
PURIFIERS/FILTERS
Filters for Specialty Gases and Liquids

Gas and liquid sample analyzer filters help protect analyzers from
sample impurities by removing solids and liquids from gases with
99.99% efficiency at 0.01 micron. Sample filters offer liquid
filtration efficiency to 2 micron or lower.

Typical Applications
■ Gas and liquid sample analyzers
■ Cylinder gas filtration

Features and Benefits


■ Remove liquids and solids from gas samples
■ Remove solids and gas bubbles from liquid samples
■ Coalesce and separate two liquid phases
www.praxair.com/specialtygases

■ Filter solids and liquids from gases with 99.99% efficiency


at 0.01 micron
■ Inert to most gases and liquids
■ Temperature resistance to 300 oF (150 oC)
■ Low pressure drop
■ Long life between filter element changes
■ All filters are CRN registered across Canada

Filter Cartridge Description


■ Q-Type Cartridges ■ Gas Filtration at 0.01µm
Used for solids and trace amounts of liquids in gases. 99.99%
Provide excellent chemical resistance, temperature resistance ■ Liquid Filtration at 2µm
to 300 oF (150 oC), and good mechanical handling properties 98%

Specifications and Ordering Information


1-877-PRAXAIR

Model BLS95S6 BLS37/12 BLS37/25 BLS27/35-3000 BLS27/80-3000


■ Flow Rate (100/3000 psig) 10/260 scfm 22/579 scfm 55/1447 scfm 129/3380 scfm 195/5000 scfm
■ Inlet and Outlet Ports 1/8" NPT 1/2" NPT 1/2" NPT 1" NPT 1" NPT
■ Drain Port 1/8" NPT 1/8" NPT 1/8" NPT 1/4" NPT 1/4" NPT
■ Maximum Temperature 400 oF (204 oC) 400 oF (204 oC) 400 oF (204 oC) 400 oF (204 oC) 400 oF (204 oC)
■ Maximum Pressure (1) 5000 psig 4000 psig 4000 psig 3000 psig 3000 psig
■ Shipping Weight 1 lb (0.4 kg) 6 lb (3 kg) 10 lb (5 kg) 25 lb (11 kg) 25 lb (11 kg)
■ Dimensions 1.8" D x 4" L 2.8" D x 5.8" L 2.8" D x 10" L 4.0" D x 16" L 4.0" D x 27" L
(4.6 cm x 10.1 cm) (7.1 cm x 14.7 cm) (7.1 cm x 25.4 cm) (10.1 cm x 40.6 cm) (10.1 cm x 68.6 cm)

Materials
Model BLS95S6 BLS37/12 BLS37/25 BLS27/35-3000 BLS27/80-3000
■ Head, Bowl, Internals(2) 316SS 316SS 316SS 316SS 316SS
■ Seals Viton® Viton Viton Viton Viton
(1) (2)
Maximum pressure ratings are for temperatures to Constructed of materials which comply with NACE specification MR-01-75.
200 oF (93 o C). Please consult Praxair for maximum Request certificate of compliance.
pressure ratings at elevated temperatures.

Option
Filter Model BLS95S6 BLS37/12 BLS37/25 BLS27/35-3000 BLS27/80-3000
Support core, required for liquid filtration Included BLSSS-100-12 BLSSS-100-25 BLSSS-200-35 BLSSS-200-80
Filter cartridges (box of 10) BLS050-11-BQ BLS100-12-BQ BLS100-25-BQ BLS200-35-BQ BLS200-80-BQ
F Please refer to page F80 for information about coalescing filters

82
GAS HANDLING EQUIPMENT
PURIFIERS/FILTERS
Thermal Gas Purifiers

Introducing Restek’s line of re-engineered thermal gas purifiers.


This line of purifiers works by producing a chemical reaction between impurities in the
carrier gas stream and the getter material. Because the reaction is non-reversible, there
is no possibility of contaminants breaking through the thermal gas purifier.
Gas purification is very economical when using a thermal gas purifier. After initial
installation cost, getter tubes only require changing once every year; heavy use and
very impure feed gas may require more frequent getter tube replacement.

Features and Benefits


■ Removes oxygen, water, carbon mon- ■ Welded end-fittings on getter tubes
oxide, carbon dioxide and hydrocarbons eliminate leaks
■ Purity in ppb levels ■ Packed with reactor-grade, pure getter
■ Mass Spec. purity carrier gas produced material for maximum efficiency and
■ Dual-tube model purifiers double no contamination. Restek Dual-Tube Thermal Gas Purifier

1-877-PRAXAIR
capacity at less than double the price

Ordering Information
Restek Single-Tube Thermal Gas Purifier, 110 V Replacement Straight Getter Tubes*
REK21496 1/8" Fittings (each) REK21661 1/8" Fittings (each) Replacement Straight Getter Tubes
REK21497 1/4" Fittings (each) REK21660 1/4" Fittings (each)
Restek Dual-Tube Thermal Gas Purifier, 110 V * Inlet pressure rating 146 psig (10 bar)
REK21498 1/8" Fittings (each)
REK21499 1/4" Fittings (each)


www.praxair.com/specialtygases
Super-Clean™ Gas Filters

Restek’s® line of Super-Clean™ gas filters is the latest in cartridge gas filtration. Cartridge
systems make changing gas filters quick and easy. The system uses a baseplate that allows
cartridges to be exchanged without introducing oxygen. Spring-loaded check valves seal
when a filter is removed and open only when a new filter has been locked in place. There is
no longer a need for loosening and tightening fittings every time a trap is changed, and your
system will not get contaminated during the process. Also available are 2- or 3-position
baseplates, you can purify all GC gas streams at one location. Any combination is possible 2- and 3-position
because any Super-Clean™ filter cartridge can be used with any baseplate. baseplates

Features and Benefits


■ High-purity output ensures 99.9999% pure lab gas
■ Features a “quick connect” for easy, leak-free cartridge change
■ Full glass/metal design is durable

Ordering Information
Part Type of Outlet Maximum Usable for Indicator H 2O (g) Capacity Hydrocarbon Estimated
Number Filter Gas Quality Pressure Color Damage O2 (ml) Lifetime (years)
REK22028 Moisture >99.9999 160 psig (11 bar) Inert carrier gas Brown to White 7.2 N/A N/A >2 years
REK22029 Oxygen >99.9999 160 psig (11 bar) Inert carrier gas Green to Grey N/A 1000 N/A >2 years
REK22030 Hydrocarbons >99.9999 160 psig (11 bar) Inert carrier gas No Indicator N/A N/A not specified >2 years
Air – Hydrogen
REK22022 Fuel Gas Filter >99.9999 160 psig (11 bar) Inert carrier gas Brown to White 3.6 N/A not specified >1.5 years
Air – Hydrogen
REK22020 Triple >99.9999 160 psig (11 bar) Inert carrier gas Brown to White 1.8 500 not specified >1 year
(Moist/O2/HC) Green to Grey

Optional Equipment
Part Number Option Description
REK22019 Carrier Gas Cleaning Kit Includes mounting baseplate, 1/8" inlet/outlet fittings, and oxygen/moisture/hydrocarbon triple filter.
REK22021 FID Fuel Gas Filter Kit One fuel gas filter and one single-position baseplate.
REK22031 Filter Bundle Kit Two fuel gas filters for FID fuel gases and one Triple Filter for carrier gas.
REK22025 Single-Position Baseplate * Single-Position baseplate.
REK22026 2-Position Baseplate * 2-Position baseplate. F
REK22027 3-Position Baseplate * 3-Position baseplate.
REK22023 Replacement O-Rings For filter cartridge baseplates (20-pack – 10 large and 10 small). 83
* All baseplates fittings are 1/8". To adapt for 1/4" fittings, use a 1/8" to 1/4" tube-end union (5 pack). Part number REK21833.
GAS HANDLING EQUIPMENT
PURIFIERS/FILTERS
Gas Specific Purifier and Contaminant Traps Purifiers

Gas specific purifier modules are designed to be placed in-line with


the Gas Chromatograph (GC) carrier gas supply or the GC detector
gas supply. There are three groups of contaminants that impact gas
chromatography: moisture, hydrocarbons and oxygen. The Gas
Specific Purifiers remove the three contaminant groups from analy-
tical gases prior to entering the GC. Proprietary absorptive materials
capture and retain contaminants for the operating life of the purifier.
The new gas specific purifier modules offer dramatic reductions in
most contaminant levels (from many parts per million to levels that
are below the lower limit of analytical detection) and absorb a larger
number and variety of contaminants than other competitive products.
The performance is optimized by incorporating a multiple bed form so
that each successive bed functions at a lower contaminant concen-
tration. The result is a series of contaminant concentration gradients Inlet gas containing oxygen, High purity
across the length of the purifier module. When these advanced ma- moisture and hydrocarbons outlet gas
terials and design features are combined with a known gas contami-
www.praxair.com/specialtygases

nant concentration, the following performance should be achieved.


Gas purifiers are designed to help insure the purity of your analytical
gases at the point of use. Even though you may be purchasing ultra-
high purity gases, your delivery system may be compromising the
level of gas purity you require. The best way to make sure your instr-
uments are receiving the highest level of gas purity is to utilize point By combining several beds of specialized sorbent materials, a contaminant
of use purification. gradient is formed across the entire length of the purifier. This successive
bed format achieves the highest purity gas commercially available.

Features and Benefits 20000

18000
■ Decrease Baseline Noise and Increase GC/MS Sensitivity Plot A – Chromatography Designed to deliver gases
16000 grade helium prior to purifier
■ Reduce Gas lmpurities from High ppm to Low ppb Levels at the point of use that
14000 are at least as pure as
■ The Ultimate Purification Technology
what was purchased in
Abundance

12000
the cylinder. Point of use
10000
Specifications purification is the best way
8000 to help insure that your

■ Length ■ Pressure Drop, 827 kPa application is receiving the


6000
21" (52.3 cm) (120 psig) inlet, at a flow of Plot B – Chromatography highest level of gas purity
1-877-PRAXAIR

■ Diameter 0 to 500 ml/min 4000 grade helium with purifier


possible.
1.5" (3.8 cm) <2.1 kPa (0.30 psig) 2000
■ Maximum Inlet Pressure ■ Compression End Connections
0
300 psig (2070 kPa) 1/8" or 1/4"
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4
■ Maximum Recommended Flow ■ Shipping Weight Min.
500 ml/min 1.76 lb (800 g) Mass scan range, 10-425 amu

Ordering Information
Product Description Part Number Fitting CO CO2 O2 H2 O Sulfur NMHC*
Compounds
Helium Purifier MATP-100-1 1/8" <1 <1 <1 <1 <1 <3
MATP-100-2 1/4"
Hydrogen Purifier MATP-200-1 1/8" <1 <1 <1 <1 <1 <3
MATP-200-2 1/4"
Nitrogen Purifier MATP-300-1 1/8" <1 <1 <1 <1 <1 <3
MATP-300-2 1/4"
Air Purifier MATP-400-1 1/8" <1 <3
MATP-400-2 1/4"
Moisture Trap MATT-100-1 1/8" <1
MATT-100-2 1/4"
Hydrocarbon Trap MATT-200-1 1/8" <3
MATT-200-2 1/4"
Oxygen Trap MATT-300-1 1/8" <1 <1
MATT-300-2 1/4"
Sulfur Trap MATT-400-1 1/8" <1 <1
Methane MATT-500-1 1/8" <1 <1 <1 <1 <1 <3
F
Note: Above values are expressed as ppb levels. * NMHC stands for non-methane hydrocarbons.
84 Guide assumes inlet gas supply less than 50 ppm (contaminents)
GAS HANDLING EQUIPMENT
PURIFIERS/FILTERS
High Pressure Purifier (Model SG6140)

Praxair’s SG6140 purifier is designed to remove water and/or oil from gas or liquid streams.
It protects sensitive instruments, prolongs service life and provides more accurate, reproducible
test results. This purifier may be used with non-corrosive gases compatible with brass and Viton®
at pressures up to 3000 psig. Three different purifying elements are available (see Ordering
Information and Optional Equipment). These elements can be replaced without removing the
purifier from the process line.

Specifications
■ Maximum Operating Pressure ■ Dew Point Obtainable ■ Dimensions
3000 psig 4A/13X Molecular Sieve: 5-11/16" H x 2" D
■ Pressure Drop -100 oF ■ Mounting Holes (2)
1.0 psi at 56 slpm Air, 2.4 psi ■ Inlet & Outlet Connections 1/4" 20UNC x 3/8" deep
at 85 slpm Air 1/4" FPT ■ Approximate Weight: 3 lb SG6140 Purifier Element

Materials

1-877-PRAXAIR
■ Purifier ■ Purifier Element ■ Purifier Element ■ Purifier Element
Body and Cap: Brass Housing: Electrolytic Tin-Plated Retainer: Polyester Felt Backed Desiccant: 4A, 13X or
O-Ring Seal: Viton® Cold-Rolled Steel Type 316 SS Screen Activated Charcoal as ordered

Ordering Information Optional Equipment


Part Element Used for Water Capacity at Flow Part Replacement Elements
Number Type* Removing Rate of 2 scfm at 80 oF Number and O-Ring
ADVSG6140 None N/A N/A ADVSG6141 Type 13X Molecular Sieve
ADVSG6140-1 Type 13X Molecular Sieve Oil and Water 5.5 grams ADVSG6142 Type 4A Molecular Sieve


ADVSG6140-2 Type 4A Molecular Sieve Water 6.0 grams ADVSG6143 Activated Charcoal
ADVSG6140-3 Activated Charcoal Oil and Heavy Hydrocarbons** N/A ADV0202-3268 Replacement Viton® O-Ring

www.praxair.com/specialtygases
* Elements are shipped in individually packed, hermetically sealed cans to prevent deterioration. They must be installed before using the purifier.
** Will remove trace amounts of Acetone in Acetylene.

Low Pressure, High Flow Purifier (Model AG6170)

Praxair’s AG6170 purifier protects sensitive instruments from water and/or oil contamination which
ensures more accurate, reproducible test results and prolongs the instrument’s service life. This purifier
(capable of removing up to 20 times more water than our Model SG6140), may be used with non-corrosive
gases compatible with aluminum and neoprene at inlet pressures up to 350 psig. Three different purifying
elements are available (see Ordering Information and Optional Equipment). These elements can be
replaced without removing the purifier from the process line.

Specifications
■ Maximum Operating Pressure ■ Pressure Drop ■ Dimensions
350 psig 0.12 psi at 85 slpm air 15-5/8" H x 4-3/4" D
■ Operating Temperature Range 1 psi at 226 slpm air ■ Approximate Weight
o o
-40 F to +200 F ■ Dew Point Obtainable 7 lb
■ Maximum Flow Capacity (4A and 13X M.S.):
280 slpm for short periods -100 oF (1.5 ppm)
(<15 mins), 85 slpm for ■ Inlet & Outlet Connections AG6170 Purifier,
continuous service 1/4" MPT Element and Gaskets

Materials
■ Purifier ■ Purifier ■ Purifier Element ■ Purifier Element
Shell and Flange Plate: Strainer Assembly: Housing: Electrolytic Tin-Plated Desiccant: 4A, 13X or
Aluminum Monel and Brass Cold-Rolled Steel Activated Charcoal as ordered
Seals: Neoprene Retainer: Polyester Felt Backed
by Type 316 SS Screen

Ordering Information Optional Equipment


Part Number Element Type Used for Removing Water Capacity Part Number Replacement Element
ADVAG6170 None N/A N/A (includes replacement gaskets)
ADVAG6170-1 Type 4A Molecular Sieve Water 134 grams ADVSG6171 Type 4A Molecular Sieve
ADVAG6170-2 Type 13A Molecular Sieve Oil and Water 126 grams ADVSG6172 Type 13X Molecular Sieve
ADVAG6170-3 Activated Charcoal Oil and Heavy Hydrocarbons** N/A ADVSG6173 Activated Charcoal F
* Elements are shipped in individually packed, hermetically sealed cans to prevent deterioration.
They must be installed before using the purifier. 85
** Not suitable for Acetylene service.
GAS HANDLING EQUIPMENT
PURIFIERS/FILTERS
Glass Encased, Low Pressure, High Purity Moisture Trap

These traps (Models SG6190 and SG6191) consist of a silanized,


borosilicate glass tube which is filled with Type 13X Molecular Sieve
and Type 4A Indicating Molecular Sieve for removal of moisture
from the gas stream. The Type 4A indicating sieve will undergo a
color change (from blue to buff) to alert when the adsorbent requires
replacement. The glass housing has been encapsulated in a secon-
SG6191 Moisture Trap
dary clear plastic outer tube to provide protection from potential
glass breakage.

Standard Features
■ Borosilicate glass inner housing eliminates contamination ■ Sintered type 316 stainless steel inlet and outlet filters
from diffusion or out-gassing commonly associated with retain the adsorbent within the column.
purifiers made of plastic. ■ Pre-purged and pressure tested with ultra-high purity
■ Transparent housing permits quick observation of the helium to insure integrity.
adsorbent’s condition. ■ Available in two different sizes.
www.praxair.com/specialtygases

Specifications Materials
■ Maximum Operating Pressure ■ Water Capacity ■ Housing ■ Filters, 40 micron
125 psig Model SG6190: 11 grams Inner Tube: Type 316 Stainless Steel
■ Maximum Operating Model SG6191: 16 grams Silanized Borosilicate Glass ■ Adsorbent Material
Temperature: 212 oF ■ Inlet and Outlet Connections Outer Tube: Type 13X Molecular Sieve
■ Efficiency 1/4" compression (standard). Polycarbonate Plastic and 4A Indicating Molecular
To <50 ppb water with inlet Optional 1/4" x 1/8" tube ■ Seals Sieve
levels of 30 ppm or less reducers available Zytel-A Nylon Resin
■ Maximum Flow Capacity ■ Approximate Weight ■ Fittings
32 slpm at 125 psi inlet 2 lb Nickel-Plated Brass

Ordering Information Optional Equipment


Part Number Size Part Number Description
ADVSG6190 1-3/4" diameter x 10" long ADVSG6195 Absorbent Refill Kit*
ADVSG6191 1-3/4" diameter x 12-1/2" long ADV0202-3027 1/4" x 1/8" Compression Tube Reducer** (2 required)
* Kit contains enough adsorbent to refill three (3) SG6190 traps or two (2) SG6191 traps. ADVMC-3 Mounting Clip with Screws (2 required)

** If selected, these items are not installed on the trap. They are shipped as separate items.
1-877-PRAXAIR

Hydrocarbon Trap

Praxair’s Model SG6130 Refillable Hydrocarbon Trap is designed to


remove trace levels of organics from carrier gases such as Helium,
Argon, Nitrogen, Hydrogen and Air. The Model SG6130 is packed
with a baked coconut shell based activated carbon to effectively
remove alcohols, aromatics, chlorinated hydrocarbons, ethers,
hydrocarbons, ketones, mercaptans, and organic acids. SG6130 Hydrocarbon Trap
Service life of these traps will vary depending on the incoming hydro-
carbon level in the carrier gas. However it is estimated that 1000 ft3 Standard Features
(3-4 cylinders) of carrier gas can be purified before the absorbent ■ Sintered type 316 stainless steel inlet and outlet filters
needs replacing. protect against adsorbent migration
■ Pre-purged and pressure tested with ultra-high purity
The all metal construction eliminates potential contamination from
outgassing or diffusion (a phenomena commonly associated with helium to insure integrity
plastic body traps).
Specifications Materials
Ordering Information Optional Equipment
■ Maximum Operating Pressure ■ Body and Caps
Part Inlet and Outlet Part Description 250 psig Aluminum
Number Connections Number ■ Maximum Operating ■ Seals
ADVSG6130-8 1/8" compression ADVSG6135 Absorbent Refill Kit* Temperature Viton ®
212 oF ■ Fittings
ADVSG6130-4 1/4" compression ADVMC-3 Mounting Clip
■ Maximum Flow Capacity Brass
* Kit contains enough adsorbent to refill two traps. 35 slpm at 120 psi ■ Filters (40 micron)
F ■ Dimensions Type 316 Stainless Steel
1-1/2" OD x 14" long ■ Absorbent Material
86 ■ Approximate Weight Baked Coconut Shell
1 lb Based Activated Carbon
GAS HANDLING EQUIPMENT
PURIFIERS/FILTERS
Disposable Oxygen Traps

Praxair’s SG6160 Series Oxygen Traps are designed to remove trace


levels of Oxygen from carrier gases such as Argon, Carbon Dioxide,
Carbon Monoxide, Helium, Hydrogen, Methane or Nitrogen. These
traps are also ideal for use with argon-methane mixtures (i.e. P-5 or
P-10 mixtures), commonly used with gas chromatographs utilizing SG6160 Oxygen Trap
electron capture detectors.
These traps incorporate a highly reactive, metal reagent, which is MC-1 Optional Mounting Clip
supported on an inert substrate, coupled with molecular sieves.
Oxygen is removed by chemical reaction with the reagent to form a
metal oxide. Oxygen levels can be effectively reduced to less than
5 ppb when starting levels are 10 ppm or less.
Service life of these traps will vary depending on the incoming Oxygen SG6162 Oxygen Trap
level in the carrier gas. However, it is estimated that when the starting
Oxygen level is <10 ppm, the Model SG6160 can purify four cylinders
(1200 ft3) of carrier gas, while the Model SG6162 can typically purify Specifications
thirty-five cylinders (10,500 ft3 ) or more. We also recommend, where ■ Maximum Operating Pressure ■ Maximum Flow Capacity

1-877-PRAXAIR
the application’s flow rates permit, using these traps upstream of our Model SG6160: 125 psig Model SG6160:
SG6150 Series Indicating Oxygen Traps (below) to provide a visual Model SG6162: 250 psig 5 slpm nitrogen at 125 psig
indication of Oxygen breakthrough, thus alerting of the need to ■ Efficiency Model SG6162-4:
replace the trap. To <5 ppb Oxygen when 20 slpm nitrogen at 80 psig
inlet levels are 10 ppm or less Model SG6162-2:
Ordering Information Optional Equipment ■ Oxygen Capacity 60 slpm nitrogen at 80 psig
Part Inlet and Outlet Part Mounting Model SG6160: ■ Dimensions
Number Connections Number Clip 260 cm3 (345 mg) SG6160: 1-1/4" D x 10" L
Model SG6162: SG6162: 2-3/8" D x 18" L
ADVSG6160-4 1/4" compression ADVMC-1 For Model SG6160


3 liters (3200 mg) ■ Approximate Weight
ADVSG6160-8 1/8" compression ADVMC-5-2 For Model SG6162
SG6160: 12 oz

www.praxair.com/specialtygases
ADVSG6162-2 1/2" compression (Set of 2)
SG6162: 3 lb
ADVSG6162-4 1/4" compression

Note: Oxygen Traps are not recommended as a replacement for the Materials
use of proper high purity gases. Rather, they are designed to provide ■ Body ■ Filters (40 micron)
additional protection from oxygen contamination which might result Aluminum Type 316 Stainless Steel
from system leaks or diffusion, or to achieve further reduction in oxygen ■ Inlet and Outlet Fittings
impurity levels for extremely sensitive instrumentation or processes. Brass

Glass Encased, Indicating Oxygen Traps

Models SG6150 and SG6151 Indicating Oxygen Traps are normally


recommended for use downstream of non-indicating oxygen traps SG1650 Trap
(where application flow rates permit) to provide a visual indication of with MC-2
oxygen breakthrough. Breakthrough is indicated via a color change in Optional
the adsorbent from gray to a deep brown. Because of their relatively Mounting Clip
small capacity, Indicating Oxygen Traps should be used by them-
selves only in low volume applications.
These traps consist of a silanized borosilicate glass tube filled with a
molecular sieve base and activated getter material. Oxygen and a
wide range of oxides react with the getter material to form a manga- SG6151 Trap
nese oxide. The glass tube is enclosed in a clear plastic outer shell to (O2 breakthrough
provide protection from glass breakage while still allowing for a visual indicated)
indication of the trap’s condition.

Specifications Materials
■ Maximum Operating Pressure ■ Dimensions ■ Housing ■ Seals
100 psig SG6150: Inner Tube: Zytel-A Nylon Resin
■ Maximum Operating 1-1/4" D x 9-1/2" L Silanized Borosilicate Glass ■ Fittings
Temperature: 212 oF SG6151: Outer Tube: Nickel-Plated Brass
■ Efficiency: 1-3/4" D x 10-3/8" L Polycarbonate Plastic ■ Filters (40 micron)
To <1 ppb oxygen with ■ Approximate Weight Type 316 Stainless Steel
inlet levels of 10 ppm or less 1 lb

Ordering Information Optional Equipment


Part Number Inlet and Outlet Connections Oxygen Capacity Maximum Flow Capacity Part Number Mounting Clip with screws
ADVSG6150-4 1/4" compression 22.5 cm3 (30 mg) 10 slpm at 100 psi ADVMC-2 For Model SG6150 F
ADVSG6150-8 1/8" compression 22.5 cm3 (30 mg) 10 slpm at 100 psi ADVMC-3 For Model SG6151 87
ADVSG6151-4 1/4" compression 75 cm3 (100 mg) 21.5 slpm at 100 psi
GAS HANDLING EQUIPMENT
PURIFIERS/FILTERS
Molecular Sieves

Molecular sieves are synthetically produced crystalline metal alu- Molecular sieves are
mino silicates that have been activated for adsorption by removing available in a variety of
their water of hydration. Unlike other adsorbents, molecular sieves package sizes from
have a precise uniform size and molecular dimension. According to 1/2 lb up to
the size of these pores, molecules may be readily adsorbed, slowly 50 lb
adsorbed or completely excluded. This sieve-like selectivity, based
on molecular size, plus a selectable preference for polar or polor-
izable molecules, gives molecular sieves an extremely high level of
adsorption efficiency, and permits close tailoring of the adsorbent
to the specific use. Pore sizes vary by the type of molecular sieve;
for example, Type 4A has a uniform pore size of 4 angstroms. Mole-
cular sieves are available in a variety of forms which include powder,
pellets, mesh and beads:
Powders are white finely divided free-flowing particles with an
average diameter of 4-5 microns.
www.praxair.com/specialtygases

Pellets are cylindrically formed products whose diameters are Table 1 – Common Screen Sizes and Openings
controlled (1/16" or 1/8" as specified).
Mesh are granular shaped products. Screen Sizes 4 8 12 14 30
Beads are spherically shaped products. Opening (mm) 4.760 2.380 1.680 1.410 0.595
The sizes of both Mesh and Bead are specified jointly by the screen ■ Molecular sieves are available in a variety of package sizes
sizes that the material will pass through and be retained by. For from 1/2 lb up to 50 lb.
example, a 14 x 30 mesh product will pass through a 14 mesh ■ Molecular sieve types AW-300 and AW-500 are available
screen, and be retained by a 30 mesh screen. The following chart upon request. Please contact your Praxair representative
lists the screen openings for some common screen sizes: for more information.

Packaging Type 3A Type 4A Type 5A Type 13X


CAS No. K2 O 12136-45-7 Na2O 1313-59-3 CaO 1305-78-8 Na2O 1313-59-3
Na2O 1313-59-3 Al2O3 1344-28-1 Na2O 1313-59-3 Al2O3 1344-28-1
Al2O3 1344-28-1 SiO2 7631-86-9 Al2O3 1344-28-1 SiO2 7631-86-9
SiO2 7631-86-9 MgO 1309-48-4 SiO2 7631-86-9
Application For commercial dehydra- For static dehydration in a closed For separating normal For general gas drying;

tion of unsaturated hydro- or liquid system. Used in packag- paraffins from branched- air plant feed purification
carbon streams such as ing of drugs, electronic compo- chain and cyclic hydro- (simultaneous removal of
1-877-PRAXAIR

cracked gas, propylene, nents, and perishable chemicals; carbons through a selec- H2O and CO2); and liquid
butadiene and acetylene. and as a water scavenger in paint tive adsorption process. hydrocarbon and natural
Also used for drying polar and plastic systems. Also used gas sweetening (H2S and
liquids such as methanol commercially in drying saturated mercaptan removal)
and ethanol hydrocarbon streams
Powder 1/2 lb ADVMS 1001 ADVMS 1069 ADVMS 1179 ADVMS 1328
2 lb ADVMS 1003 ADVMS 1071 ADVMS 1181 ADVMS 1330
12 lb ADVMS 1005 ADVMS 1073 ADVMS 1183 ADVMS 1332
30 lb ADVMS 1006 ADVMS 1074 ADVMS 1184 ADVMS 1333
Pellets 1 lb ADVMS 1028 ADVMS 1096 ADVMS 1206 ADVMS 1355
1/8" 5 lb ADVMS 1030 ADVMS 1098 ADVMS 1208 ADVMS 1357
25 lb ADVMS 1032 ADVMS 1100 ADVMS 1210 ADVMS 1359
50 lb ADVMS 1034 ADVMS 1102 ADVMS 1212 ADVMS 1361
Pellets 1 lb ADVMS 1014 ADVMS 1082 ADVMS 1192 ADVMS 1341
1/16" 5 lb ADVMS 1016 ADVMS 1084 ADVMS 1194 ADVMS 1343
25 lb ADVMS 1018 ADVMS 1086 ADVMS 1196 ADVMS 1345
50 lb ADVMS 1020 ADVMS 1088 ADVMS 1198 ADVMS 1347
Beads 1 lb ADVMS 1138 ADVMS 1362
4x8 5 lb ADVMS 1140 ADVMS 1364
25 lb ADVMS 1142 ADVMS 1366
50 lb ADVMS 1144 ADVMS 1368
Beads 1 lb ADVMS 1124 ADVMS 1369
8 x 12 5 lb ADVMS 1126 ADVMS 1371
25 lb ADVMS 1128 ADVMS 1373
50 lb ADVMS 1130 ADVMS 1375
Beads 1 lb ADVMS 1152
8 x 12 with 5 lb ADVMS 1154
Indicator 25 lb ADVMS 1156
F Mesh 1 lb ADVMS 1110
14 x 30 5 lb ADVMS 1112
88 25 lb ADVMS 1114
50 lb ADVMS 1116
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Overview – Life Sciences

Solutions from Discovery to


Production
For Life Science companies concerned with
GMP and FDA compliance, Praxair provides
reliable gas delivery, consistent product
quality and complete equipment solutions
for all gas-related applications from the
research and discovery phase through to
production.
■ Growing Cultures
■ Analytical Research
■ Clinical Trials
■ Storing Cells/Molecules

1-877-PRAXAIR
■ Regulatory Compliance
■ Quality Assurance
■ Quality Control


We have adapted our offerings to accom- ■ GMP – FDA Compliance ■ New innovative product development

www.praxair.com/specialtygases
modate the requirements of small biotech ■ A supplier who is predictable and acts aimed directly at specific industry
companies, working with our customers as a trusted partner applications services that enable facilities
through the rapid growth progression to management to cost effectively manage
■ Demonstrated MOC (management of
large fortune 500 companies. This is why so expansions and build-outs, laboratory
change) process
many Biotechnology and Pharmaceutical renovations, repository systems
companies choose Praxair: ■ One Stop Shop – complete and
comprehensive solutions

Gases Equipment Services


■ Cryogenic Gases ■ Cryobiological Equipment ■ Preventative Maintenance
■ Bulk Supply ■ Storing/Archiving Freezers ■ Emergency Response
■ Microbulk ■ Dry Shippers for Sample ■ Service Calls/Support
■ Liquid Containers Transportation ■ System Design Consulting
■ Laboratory/Instrument Gases ■ Dry Ice Bins and Packages ■ Site Gas Management
■ FDA Regulated Gases ■ VJP Piping ■ E-Business Options
■ Incubation Gases – ■ Gas Delivery Solutions ■ Site Evaluations
Biological Atmospheres ■ Gas Regulation Equipmentt ■ Remote Liquid Level Monitoring
■ Dry Ice ■ Gas Generator/Membrane Options ■ Training and Education
■ Gas Generator/Membrane Options (outright purchase) ■ Technical Support
(rental) ■ Safety and Gas Detection

Cryobiological Equipment – Time, Temperature and Viability


To fully realize the benefit of biological re- We are staffed with market, sales, and
search, the protection of valuable samples research personnel dedicated to the
is paramount. We can provide critical in- pharmaceutical and biotech markets.
formation, which is sure to benefit anyone Combined with our strategic alliances,
with an interest in the long-term storage and we can assist you with principles such as:
maintenance of biologicals, for example: ■ Mechanisms and bio physics of
■ Minimizing damage throughout the freezing biologicals
freezing process ■ Critical temperatures
■ Maximizing viability throughout the ■ Storage repository design and practice
F
storage period
89
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Cryogenic Gas Systems Integration

The Viability Imperative

Cryobiology applications require the most Safety by Design low temperature alarms etc. When an alarm
thermally efficient storage and distribution is detected by the E-Stop Control System,
A major consideration in any piping system
systems. Vacuum jacketed piping plays the valve at the bulk supply point is closed,
design is safety.
a significant role in achieving optimal effi- preventing additional ingress of nitrogen into
ciency. Chart and Praxair’s combined years In addition to providing relief systems to the hazard area.
of cryogenic experience provide the added safely vent vaporized liquid, all vacuum
Oxygen deficiency monitoring is a vital
assurance the system will be designed jacketed piping systems are specified with
component of the safety system. The
and installed to ideally suit the application. an automatic, hydraulic shut-off system
PointGuard™ Oxygen Deficiency Monitor
Thermal efficiency and pressure manage- designed to close down the liquid supply
from Draeger is a very high quality system
ment of cryogenic gases liquids are the at the bulk tank, in the event of an alarm
with outputs compatible with the Chart
most critical variables. Our approach to associated with an excess LN2 condition.
E-Stop System. The units can be net-
cryobiology piping system design is holistic,
The E-Stop Control System from Chart worked and calibrated and form a flexible,
examining the entire application before sub-
accepts interfaces from alarm systems accurate safe system.
www.praxair.com/specialtygases

mitting a design. These designs ensure


such as oxygen monitors, high level and
flexibility for future expansion potential.
From engineering and layout to system in-
stallation and start up Praxair can provide
a single point of contact.

■ Safety
(associated with liquid nitrogen)
■ Temperature
(cell viability and critical temperatures
of biological materials)
■ Security
(of samples stored)
■ Cost
(overall cost of ownership)

1-877-PRAXAIR

F
90
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Cryogenic Gas Systems Integration

Temperature ciated with liquids at cryogenic temperature The properly designed vacuum jacketed
necessitates a unique approach. The lower piping system minimizes the infiltration of
Liquid Nitrogen:
the pressure the more cooling capacity pro- heat into the system as a whole, which
-196 Deg C. In terms of cryobiology,
vided to the application, therefore the first reduces operating costs and provides liquid
there is no such thing as too cold.
and by far the most important area is pres- on demand, every time. Chart vacuum
The most important element of a low- sure management. Given the low pressure insulated piping is the result of 30 years of
temperature storage system is ensuring a requirements of the cryobiology storage continuous design and build improvement
constant range of temperatures below a application, thermal management and in the pursuit of manufacturing excellence.
minimum critical threshold. What is the pressure drop across the system are also The inner pipe in the system utilizes the
critical temperature of the material you wish very critical. same multi-layer component super insu-
to store? Critical temperature -150 Deg C lation which gives our cryogenic tanks world
is required for Cells, Bacteria, Blood and Security for Samples leading performance. Chart also pioneered
Algae. Materials such as proteins and nuc- bayonet type connections throughout Cryo-
The success of any liquid system starts
leic acids that can nominally be stored at Bio applications, giving tight seals and
at the point of use, or the application and
-20 Deg C will be as stable, or even more higher performance with low LN2 usage.

1-877-PRAXAIR
works its way back to the cryogenic liquid
stable at lower temperatures. See table 1 The T304 stainless inner – internal bellows
storage.
below for details. vacuum pipe we offer is an industrial/
The Praxair and Chart team of engineers commercial grade built to the same rigid
From a cryobiology point of view, the
will conduct a total site survey performed requirements as ASME piping. Internal
sample must be stored at a temperature
with a multitude of thought provoking bellows eliminate contraction of the outer
sufficiently below the critical temperature so
questions to make sure all situations are jacket, meaning no convoluted hosing is
that normal operation of the storage system
considered for sample security. The Chart required.
will ensure the samples will not inadvertently
freezers offer full function alarm systems
rise above that temperature. Additionally,


for low and high liquid level, high and low Cost
the failure mode of the system should allow
temperature for each of the 2 RTD probes,

www.praxair.com/specialtygases
for sufficient time for remedial action to be We recognize that managing costs have
LN2 supply, valve failure and power failure.
taken in the event of such a failure, within required companies to improve operating
Additional controller options allow for
normal working conditions. efficiencies.
battery back-up systems for protection
The movement of cryogenic liquids at the against electrical supply interruptions. The A “cost of ownership (COO)” analysis is the
extremely cold temperatures required for hot gas bypass system vents incoming gas best way to understand the impact of your
cryobiology applications is demanding and until the liquid reaches the valve, minimizing purchasing decisions. Praxair can provide
complex. The special requirements asso- the normal losses associated with filling various COO models to help you evaluate
from liquid containers. the best gas, equipment and system deci-
sions for your facility; examples include:
Table 1 ■ Analyzing your current and future liquid
Material to Volume Container Inventory Critical and gas volume requirements will deter-
be Stored Configuration Temperature mine the most cost effective mode(s) of
Algae 0.5 - 1.0 m Cryovial Boxes or canes -150 oC supply, dewars, microbulk, bulk tank,
Bacteria 0.5 - 1.0 ml Cryovial Boxes or canes -80 oC membrane or high pressure cylinders
Bacteriophage 0.5 - 1.0 ml Cryovial/Eppendorf Tube Boxes or canes -80 oC ■ Facility layout and logistics will impact
Blood 0.5 - 500 ml Cryovial/Blood Bag Boxes or canes/ -150 oC piping system decisions
bag rack ■ Mechanical freezers (energy, mainte-
Cells nance, life) vs. cryogenic storage
Animals/Human 0.5 - 1.0 ml Cryovial Boxes or canes -150 oC
At your request Praxair can work directly
Plant 0.5 - 1.0 ml Cryovial Boxes or canes -150 oC
Embryos Straw Canes -150 oC with architectural or consulting engineers
for large expansions and new construction.
Fungi
Gas-handling equipment and delivery sys-
Mycelium 0.5 - 1.0 ml Cryovial Boxes or canes -150 oC
Spores 0.5 - 1.0 ml Cryovial Boxes or canes -80 oC tems can be purchased directly from
Hybridomas 0.5 - 1.0 ml Cryovial Boxes or canes -150 oC Praxair, eliminating extra costs typically
associated with contractor purchases.
Nucleic Acids
DNA milli/micro grams Cryovial/Eppendorf Tube Boxes >-20 oC System design services are available from
RNA milli/micro grams Cryovial/Eppendorf Tube Boxes >-20 oC the simplest to the most complex projects
in addition to full turnkey packages.
Phage
Libraries 0.5 - 1.0 ml Cryovial Boxes or canes -150 oC The rewards of bringing innovative techno-
Plasmids milli/micro grams Cryovial/Eppendorf Tube Boxes -80 oC logies into your business can be tremen-
Proteins Boxes >-20 oC
dous and will give your company an edge in
Protozoa 0.5 - 1.0 ml Cryovial Boxes or canes -150 oC
an increasingly competitive global market-
Viruses: Animal place. The Praxair/Chart team is ready to
Cell-Free 0.5 - 1.0 ml Cryovial Boxes -80 oC
show you what it means to have a uniquely F
In Cells 0.5 - 1.0 ml Cryovial Boxes or canes -150 oC
capable, enthusiastic, and resourceful 91
Plant 0.5 - 1.0 ml Cryovial Boxes -80 oC
supplier working on your behalf.
Source: F. Simeone, American Type Culture Collection, Manassas, VA
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Liquid Nitrogen High Efficiency Freezers

MVE’s HE Series
■ Only freezer on the market specifically designed for
vapor storage.
■ Unequaled quality of vacuum with industry leading
5 year warranty.
■ Efficient thermal design ensures 95% of system surface
area enclosed by vacuum compared to typical 60% in
standard freezers.
■ Lowest under lid temperature in the industry at minus 190 oC.
This ensures an increased safety margin below the Glass
Transition Temperature and better long term sample viability.
■ Lowest liquid usage – typically 40% below equivalent standard
tanks of similar capacity. Note that NER’s for competitive tanks
are calculated before the addition of the vapor sleeve, which will
www.praxair.com/specialtygases

increase consumption of LN2 by 50% or more.


A Offset neck design to maintain
■ No artificial aids required to lower and maintain temperature as -190 oC in vapor storage and
with competitive tanks. HE gives lowest running cost/sample. provide low liquid nitrogen con-
■ Liquid reservoir below sample platform will maintain temperature sumption with standard racks
for more than 14 days typically. B Durable metal lid – designed
■ Validated to maintain temperature of samples for at least for longer life
C Rotating interior tray provides
two (2) hours with the lid removed.
easy access to cryobiological
■ Compact design means highest number of vials stored samples
per square foot of laboratory space. D Low maintenance, all-stainless
■ Differential pressure level measurement – seamless measurement steel construction
is important in vapor systems as the LN2 level is a small range – E Annular filling lines reduce
frost and ice formation near lid
typically 4 to 8 inches only.
F Super-tough, durable casters
■ Temperature measurement by RTD, the most accurate system G Rack stand
available. 2 point calibration ensures compliance with GLP H Step-up platform
and GMP. (MVE 1520HE, 1830HE)

1-877-PRAXAIR

Specifications
Model MVE 810HE MVE 1520HE MVE 1830HE Unit Capacities - MVE 810HE - Blood Bags
Part Number* MVE10753022 MVE10784056 MVE10734690 Part Number Frame Ht (in/mm) Bags/Frame No. Frames Total Bags
Liquid Nitrogen Capacity (Liters) 370 756 1,612 MVE4R9951 25.5 (648) 6 104 624
Liquid Nitrogen Capacity Under 52 133 260 MVE4R9953 26 (660) 4 88 352
Platform (Liters) MVE4R9955 26 (660) 4 68 272
Neck Opening (in/mm) 12.5 (318) 17.5 (445) 25 (635) MVEDF200 26 (660) 4 52 208
Useable Internal Height (in/mm) 28.8 (731) 28.6 (726) 28.6 (726) MVEDF700 N/A N/A N/A N/A
Inner Diameter (in/mm) 28.5 (724) 38.5 (978) 56.3 (1,430) MVEC7005 23.5 (597) 3 68 204
Overall Height (in/mm) 47.3 (1,201) 53.2 (1,351) 58.4 (1,483) MVEC7400 28.5 (724) 3 68 204
Outer Diameter (in/mm) 32 (813) 42 (1,067) 60 (1,524)
Weight Empty (lb/kg) 475 (216) 600 (272) 1,500 (681) Unit Capacities - MVE1520HE - Blood Bags
Part Number Frame Ht (in/mm) Bags/Frame No. Frames Total Bags
Unit Capacities – Vials
MVE4R9951 25.5 (648) 6 192 1,152
1.2 and 2ml Vials MVE4R9953 26 (660) 4 176 704
(Internally Threaded) MVE4R9955 26 (660) 4 140 560
Number of Racks (100 cell boxes) 12 24 54 MVEDF200 26 (660) 4 108 432
Number of Racks (25 cell boxes) 4 16 30 MVEDF700 26 (660) 4 56 224
Number of Stages per Rack 12 13 13 MVEC7005 23.5 (597) 3 144 432
Total Vial Capacity 15,600 36,400 79,950 MVEC7400 28.5 (724) 3 144 432
5ml Vials
(Internally Threaded) Unit Capacities - MVE1830HE - Blood Bags
Number of Racks (100 cell boxes) 12 24 54 Part Number Frame Ht (in/mm) Bags/Frame No. Frames Total Bags
Number of Racks (25 cell boxes) 4 16 30 MVE4R9951 25.5 (648) 6 456 2,736
Number of Stages per Rack 7 8 8 MVE4R9953 26 (660) 4 390 1,560
Total Vial Capacity 9,100 22,400 49,200 MVE4R9955 26 (660) 4 276 1,104
* Part numbers refer to full auto control freezers. Basic models or freezers with MVEDF200 26 (660) 4 210 840
battery back-up and gas bypass systems are available. Please consult your local MVEDF700 26 (660) 4 126 504
F Praxair representative. MVEC7005 23.5 (597) 3 276 828
92 MVEC7400 28.5 (724) 3 276 828
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Liquid Nitrogen Freezers

MVE’s Stock Series


The Stock Series tanks from MVE are pri-
marily designed for storage of either vials or
straws on canes in liquid nitrogen. Dual lids,
and in the case of the XLC 1830, a rotating
tray, are provided to ensure easy access to
the units, making multiple sample retrieval
ergonomically efficient. The units are built
with long life and durability in mind and
provide secure long-term storage for your
samples.

Accessories
Square racks – stainless or aluminum

1-877-PRAXAIR

■ Cardboard boxes (81 cell)


■ Plastic boxes (25 cell and 100 cell)
■ SUC boxes
■ Canes and protectors
■ Cryogenic gloves


Specifications
Model MVE 140 MVE 810 MVE 1370 MVE 1830 MVE 18302T

www.praxair.com/specialtygases
Part Number* MVE9918669 MVE10752871 MVE10751676 MVE10752097 MVE10752177

Maximum Storage
Capacity
Number of 1.2 and 2.0 ml – 11,700 24,400 – –
vials in racks
Number of racks (100 vials) – 12 (9/2 rack) 28 (8/2 rack) – –
Number of racks (25 vials) – 4 (9/2 rack) 8 (8/2 rack) – –
Total number of racks – 16 36 – –
Number of blood bags stored – N/A N/A N/A N/A
(Fenwal 4R-5461)
Number of SUC-1 canisters 22 76 152 306 561
(2.5" x 2.5" x 11")
Number of 1.2 & 2.0 ml 3,696 14,136 28,272 56,916 104,346
vials on canes
Number of 1/2 cc straws 6,820 23,560 47,120 94,680 187,550
(10/cane) A Metal lid construction –
designed for longer life
Performance
B Tough, durable hinges
Liquid nitrogen capacity
(liters) 39 230 482 860 1400 C Annular filling lines to reduce frost
Power supply – 24 VDC 24 VDC 24 VDC 24 VDC and ice formation
D Maintains -125 oC under the lid
Dimensions temperature in vapor phase storage;
Neck Opening (in/mm) 16.0 (406) 25.0 (635) 35.5 (902) 25.0 (635) 25.0 (635)
-196 oC liquid phase storage
Usable height (in/mm) 12.0 (305) 21.4 (544) 19.4 (492) 13.0 (330) 2’ x 3' (610 x 914)
E Low maintenance, all
Overall height (in/mm) 17.5 (445) 41.5 (1054) 44.0 (1172) 40.9 (991) 53.9 (1368)
Outside diameter (in/mm) 18.0 (457) 31.0 (787) 42.0 (1067) 60.0 (1524) 60.0 (1528) stainless steel construction
Internal diameter (in/mm) 16.0 (406) 28.2 (716) 39.5 (1003) 56.0 (1422) 56.3 (1430) F Tough, durable casters
Weight empty (lb/kg) 48.0 (22) 250 (114) 410 (186) 984 (447) 1184 (538) G Optional vapor platform
Weight full (lb/kg) 117 (53) 660 (300) 1269 (577) 2517 (1144) 3700 (1682)
* Part numbers refer to full auto control freezers (with the exception of the MVE 140 model).
Basic models or freezers with battery back-up and gas bypass systems are available.
Please consult your local Praxair representative.

F
93
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Liquid Nitrogen Freezers

MVE’s 600/1400 Series


The MVE 600 and 1400 Cryo-Preservation Systems are designed
to provide storage of biological products in liquid or vapor. The large
neck opening provides easy access to all samples. The tanks large
storage capacities hold 16,900 to 26,650 vials. Combined with
a low maintenance design and the TEC 2000 electronics, the
MVE 600 and 1400 Series set the standard for low temperature
storage.

Accessories
■ Inventory frames and cassettes
■ Square racks – stainless or aluminum
■ Cardboard boxes (81 cell)
www.praxair.com/specialtygases

■ Plastic boxes (25 cell and 100 cell)


■ Cryogenic gloves
■ Transfer hose (standard)
■ Magnetic reference guide
(Standard on MVE 600 and MVE 1400 only)

Options
■ Battery back-up
■ Gas bypass

Specifications
Model MVE 600 MVE 1400
Part Number* MVE11499661 MVE11561516

Maximum Storage Capacity


1-877-PRAXAIR

Number of 1.2 & 2.0 ml vials in racks 16,900 26,650


Number of racks (100 vials) 12 18
Number of racks (25 vials) 4 10
Total number of racks 16 28
Number of 1.2 & 2.0 ml vials on canes - -
Number of 1/2 cc straws (10/cane) - -

Performance
Liquid nitrogen capacity ( liters ) 236 375
Power supply 24 VDC 24 VDC
A Durable, metal lid –
Dimensions
designed for longer life
Neck opening (in/mm) 25.13 (638) 31.75 (958) B Advanced gasket design restricts
Usable height (in/mm) 29.06 (738) 28.9 (735) ambient air flow into freezer
Overall height (in/mm) 40.38 (1026) 40.38 (1026) C Industrial-strength hinges
Outside dimensions (in/mm) 28 x 35.13 (711 x 892) 34.75 x 41.13 (882 x1044) D Aluminum cabinet
E Lowered deck height for
Internal diameter (in/mm) 25.13 (638) 31.75 (958)
easy access
Weight empty (lb/kg) 330 (150) 530 (240) F Annular filling lines to reduce
Weight full (lb/kg) 751 (341) 1198 (543) frost and ice formation
* Part numbers refer to full auto control freezers, which come standard with 115 VDC/60 Hz. G Tough, durable casters
Basic models or freezers with battery back-up and gas bypass systems are available. H Optional vapor platform
Please consult your local Praxair representative.

Unit Capacities – Blood Bags MVE 600 MVE 1400


Part Frame Ht Bags/ Number Total Number Total
F Number (in/mm) Frame Frames Bags Frames Bags
94 MVE4R8951 25.5 (648) 6 106 636 156 936
MVE4R9953 26.0 (660) 4 86 344 136 544
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Liquid Nitrogen Freezers

MVE Cryo-Preservation Systems


The MVE Cryo-Preservation systems are
designed for the user who needs either va-
por storage or liquid storage. A large neck
opening and stainless steel construction
provides the most durable environment for
your biological samples. With advanced
features and storage from 5,200 vials to
39,000 vials, the MVE series is the cryo-
logical choice.

1-877-PRAXAIR
Optional Features
■ Battery back-up. This option will atmosphere. Once the line is sufficiently
provide fill operation for 72 hours in cold, the vent valve closes and the fill to
the event of power supply failure. the freezer begins. This reduces losses
■ Gas by-pass. Monitors the tempera- due to warm gas boiling off liquid already
ture in the fill line at the start of the filling in the tank, and in conjunction with the
process. Until the line temperature falls one fill, all fill feature of the TEC2000


below a level determined by the user will optimize fill efficiency.

www.praxair.com/specialtygases
(usually -130 oC) the fill line is vented to

Accessories
■ Square racks – stainless or aluminum ■ SUC boxes
■ Cardboard boxes (81 cell) ■ Canes and protectors
■ Plastic boxes (25 cell and 100 cell) ■ Cryogenic gloves

Specifications A Metal lid construction –


designed for longer life
Model MVE XLC 230 II MVE XLC 511 MVE XLC 1211 MVE XLC 1841
B Tough, durable hinges
Part Number* MVE11004349 MVE10752767 MVE10751369 MVE10800790
C Annular filling lines to reduce
Maximum Storage Capacity frost and ice formation
Number of 1.2 and 2.0 ml vials in racks 5,200 10,400 23,400 39,000 D Maintains -125 oC under the lid
Number of racks (100 vials) 4 (13/2 rack) 7 ( 13/2 rack ) 17 (13/2 rack ) 28 (13/2 rack)
temperature in vapor phase storage,
Number of racks (25 vials) – 4 (13/2 rack ) 4 (13/2 rack ) 8 (13/2 rack)
-196 oC liquid phase storage
Total number of racks 4 11 21 36
Number of blood bag stored 132 224 480 856 E Low maintenance, all
(Fenwal 4R-5461) stainless steel construction
F Tough, durable casters
Performance G Optional vapor platform
Liquid nitrogen capacity (liters) 89 158 354 669
Power supply 24 VDC 24 VDC 24 VDC 24 VDC

Dimensions
Neck opening (in/mm) 16.0 (408) 20.8 (528) 31.0 (788) 39.5 (1003)
Usable height (in/mm) 26.9 (683) 28.6 (726) 28.6 (726) 33.3 (846)
Overall height (in/mm) 45.25 (1150) 44.2 (1123) 48.0 (1219) 48.0 (1219)
Outside diameter (in/mm) 18.0 (457) 22.75 (579) 33.0 (838) 42.0 (1067)
Internal diameter (in/mm) 16.0 (408) 20.8 (528) 31.0 (788) 39.5 (1003)
Weight empty (lb/kg) 125 (57) 242 (110) 460 (209) 675 (306)
Weight full (lb/kg) 283 (129) 524 (238) 1091 (495) 1867 (847)
* Part numbers refer to full auto control freezers. Basic models or freezers with battery back-up
and gas bypass systems are available. Please consult your local Praxair representative.

F
95
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Liquid Nitrogen Aluminum Freezers

MVE’s XC Series
With available capacities of 700 - 5000 straws, 150 to over 1000
vials, the ideal tank for any requirement is available. Manufactured to
a world class level of excellence and backed by an industry leading
5 year vacuum warranty, these durable, lightweight units can be relied
on to perform in the most demanding environments.
The XC series is designed for the user who requires large capacity
storage and low liquid nitrogen consumption in a convenient light-
weight package. By integrating features requested by customers with
the widest variety of holding times and storage capacities, MVE XC
aluminum freezers are the units of choice.

Accessories
www.praxair.com/specialtygases

■ Caster Base
■ Canister
■ Spare Corks
■ Liquid Level Measuring Stick
■ Transfer Hose
A Durable, tamper-proof lid design G Advanced chemical vacuum
■ Phase separator
B Easy maintenance lid design retention system – designed for
■ Square Racks C Superior strength, lightweight superior vacuum performance
(47/11-6 Model only) aluminum construction over the life of the product
■ Plastic Boxes D High strength neck tube H Spider design – for easy
■ Liquid Level Alarm reduces liquid nitrogen loss retreival and insertion of
E Locking tab product canisters
F Color-coded canister/lid J Insulation – MVE’s advanced
numbering system insulation system provides
maximum thermal performance

Specifications
1-877-PRAXAIR

Model XC Millennium XC 21/6 XC 22/5 XC 32/8 XC 33/22 XC 34/18 XC 35/12 XC 43/28 XC 47/11-6 SQ XC 47/11-6 XC 47/11-10
20
Part Number* MVE11082646 MVE9920579 MVE9918539 MVE9918449 MVE9918069 MVE10743027 MVE10854940 MVE9918039 MVE10811464 MVE10719924 MVE10725435

Maximum Storage Capacity


Number/size of canisters 6/11" 9/5" 6/11" 9/11" 6/11" 6/11" 10/11" 6/11" 6 Sq./2" 6/11" 10/11"
No. of 1/2 cc straws 720 N/A 2,400 2,520 1,260 2,100 2,800 1,260 – 4,500 3,500
(10/cane)
No. of 1/2 cc straws 1,122 3,870 3,666 3,960 1,764 3,000 4,400 1,764 – 6,216 5,000
(1 Level Bulk)
No. of 1.2 & 2.0 ml vials 210 N/A 810 855 360 630 950 360 – 1,320 1,050
(5/cane)
No. of Racks (25 Vials) – – – – – – – – 750 – –
Performance
Liquid nitrogen capacity 20.5 21 22.4 32 33.4 34.8 34.8 42.2 47.4 47.4 47.4
(liters)
Static evaporation rate 0.095 0.25 0.35 0.35 0.14 0.18 0.24 0.14 0.39 0.39 0.39
(liters/day)**
Normal working duration 140 53 40 57 154 123 90 193 76 76 76
(days)***
Unit Dimensions
Neck opening (in/mm) 2.18 (55.4) 3.5 (89) 3.81 (97) 3.81 (97) 2.75 (70) 3.5 (89) 4.0 (102) 2.75 (70) 5 (127) 5 (127) 5 (127)
Overall height (in/mm) 25.7 (652) 17.2 (438) 22 (559) 21.5 (546) 26 (660) 26.6 (675) 25 (635) 26.4 (670) 26.5 (673) 26.5 (673) 26.5 (673)
Outside diameter (in/mm) 14.5 (368) 18.2 (464) 14.5 (368) 18.2 (464) 18.2 (464) 18.2 (464) 18.25 (456) 20 (508) 20 (508) 20 (508) 20 (508)
Canister height (in/mm) 11.0 (279) 5.0 (127) 11.0 (279) 11.0 (279) 11.0 (279) 11.0 (279) 11.0 (279) 11.0 (279) – 11.0 (279) 11 (279)
Canister diameter (in/mm) 1.65 (41.9) 2.75 (70) 3.09 (79) 2.62 (67) 2.22 (56) 2.81 (71) 2.6 (66) 2.22 (56) – 4 (102) 2.81 (71)
Weight empty (lb/kg ) 23 (10.5) 30.0 (13.6) 26 (11.8) 30 (13.6) 34 (15.4) 34 (15.4) 34 (15.4) 36 (16.4) 42 (19) 42 (19) 42 (19)
Weight full (lb/kg) 59.5 (27) 62.5 (28.3) 66 (30) 87 (39.5) 94 (42.5) 96 (43.5) 95 (43.1) 111 (50.5) 120.4 (54.6) 120.4 (54.6) 120.4 (54.6)
* Part numbers includes the freezer and the number/size of canisters specified. ***Normal working duration is an arbitrary reference, to estimate container performance under
F For example: MVE11082646 includes six 11" canisters. normal operating conditions. Actual working time may vary due to current atmospheric
96 **Static evaporation rate and static holding time are nominal. Actual rate and holding time will be conditions, container history, manufacturing tolerances and any individual patterns of use.
affected by the nature of container use, atmospheric conditions, and manufacturing tolerances.
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Liquid Nirogen Aluminum Freezers

MVE’s SC Series
MVE offers the widest range of compact aluminum storage tanks
available on the market today. Whatever the application you will find
the perfect solution within the XC and SC product lines. Over the past
40 years these product designs have benefited from customer input
and have evolved into a unique selection of units. Each unit is
perfectly designed for various applications.

Accessories
■ Caster Base
■ Canister
■ Spare Corks
■ Liquid Level Measuring Stick

1-877-PRAXAIR
■ Transfer Hose
■ Phase separator
■ Level Alarm

A Durable, tamper-proof lid design G Advanced chemical vacuum


B Easy maintenance lid design retention system – designed for


C Superior strength, lightweight superior vacuum performance

www.praxair.com/specialtygases
aluminum construction over the life of the product
D High strength neck tube H Spider design – for easy
reduces liquid nitrogen loss retreival and insertion of
E Locking tab product canisters
F Color-coded canister/lid J Insulation – MVE’s advanced
numbering system insulation system provides
maximum thermal performance

Specifications
Models SC 3/3 SC 8/5 SC 11/ 7 SC 16/11 SC Millennium 20 SC 20/20 SC 36/32 SC 33/26
Part Number* MVE9918009 MVE9917989 MVE9918499 MVE9918519 MVE11082638 MVE10725451 MVE10829621 MVE10743035
Maximum Storage Capacity
Number/size of canisters 6 /5" 6/5" 6/11" 9/5" 6/11" 6/11" 6/11" 6/11"
No. of 1/2 cc straws - - 540 - 540 540 540 540
(10/cane )
No. of 1/2 cc straws 732 732 732 1098 780 780 780 780
(1 Level Bulk)
No. of 1.2 & 2.0 ml vials - - 150 - 150 150 150 150
(5/cane)
Performance
Liquid nitrogen capacity 3.6 8.4 11.0 16.4 20.5 20.5 36.5 33
(liters)
Static evaporation rate 0.12 0.15 0.15 0.14 0.095 0.09 0.10 0.13
(liters/day)**
Normal working duration 19 35 46 74 135 142 224 182
(days)***
Dimensions
Neck opening (in/mm) 2 (51) 2 (51) 2 (51) 2 (51) 2 .18 (55.4) 2 (51) 2 (51) 2 (51)
Overall height (in/mm) 16 (406) 18.5 (470) 21.6 (549) 17.5 (444) 25.7 (652) 27.2 (690) 25.9 (657) 25.9 (657)
Outside diameter (in/mm) 8.7 (222) 10.2 (260) 10.2 (260) 17.2 (438) 14.5 (368) 14.5 (368) 18.2 (464) 18.2 (464)
Canister height (in/mm) 5 (127) 5 (127) 11 (279) 5 (127) 11 (279) 11 (279) 11 (279) 11 (279)
Canister diameter (in/mm) 1.5 (38) 1.5 (38) 1.5 (38) 1.5 (38) 1.5 (38) 1.5 (38) 1.5 (38) 1.5 (38)
Weight empty (lb/kg) 8 (3.6) 12 (5.3) 17 (7.7) 14 (6.4) 23 (10.5) 26 (11.8) 34 (15.4) 34 (15.4)
Weight full lb (lb/kg) 14.4 (6.5) 27 (12.1) 36.6 (16.6) 43 (19.6) 59.5 (27) 100(44.8) 93.4 (42.4) 93.4 (42.4)
* Part numbers includes the freezer and the number/size of canisters specified. ***Normal working duration is an arbitrary reference, to estimate container performance under
For example: MVE9918009 includes six 5" canisters. normal operating conditions. Actual working time may vary due to current atmospheric F
** Static evaporation rate and static holding time are nominal. Actual rate and conditions, container history, manufacturing tolerances and any individual patterns of use.
holding time will be affected by the nature of container use, atmospheric conditions,
97
and manufacturing tolerances.
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Liquid Nitrogen Storage Containers

Lab Series
The Lab Series of cryogenic dewars earned their name from their
acceptance in laboratories and medical offices worldwide. These
high-efficiency, super insulated dewars are the most convenient,
economical way to store and dispense liquid nitrogen. Many lab
units can be fitted with pouring spouts, pressurized dispensing
devices or dippers to aid in the transfer of liquid nitrogen.

Accessories
■ Transfer hose ■ Dipper
■ Phase separator ■ Spare corks
■ Pouring spout ■ Pressurized discharge device
■ Swivel dipper ■ Caster base
www.praxair.com/specialtygases

A Easy maintenance lid design


B High strength neck tube
reduces liquid nitrogen loss
Please ask your local
C Advanced chemical vacuum
Praxair representative about retention system – designed
our cryogenic gases, for superior vacuum perfor-
delivery solutions and services. mance over the life of the
(See page F89) product
D Superior strength, lightweight
aluminum construction
E Insulation – MVE’s advanced

insulation system provides


maximum thermal performance
1-877-PRAXAIR

Specifications and Ordering Information


Model LAB 4 LAB 5 LAB 10 LAB 20 LAB 30 LAB 50 SS Transfer Unit
Part Number MVE9922219 MVE9918079 MVE10740281 MVE10756338 MVE9918099 MVE9918109 MVE11014070

Net Capacity (liters) 4 5 10 21 32 50 5

Performance
Static Evaporation 0.19 0.15 0.18 0.18 0.22 0.49 N/A
Rate (liters/day)

Dimensions
Neck opening (in/mm) 1.4 (35.5) 2.2 (56) 2.2 (56) 2.0 (51) 2.5 (64) 2.5 (64) 6.0 (152)
Usable height (in/mm) 7.8 (198) 10.5 (266) 13.5 (343) 13.7 (348) 14.9 (378) 22.0 (559) 14.0 (356)
Overall height (in/mm) 16.8 (426) 18.2 (462) 21.5 (546) 24.7 (627) 24.1 (611) 30.7 (779) 16.5 (419)
Outside diameter (in/mm) 7.3 (185) 8.8 (222) 10.3 (260) 14.5 (368) 17.0 (432) 17.0 (432) 8.0 (203)
Internal diameter (in/mm) 5.5 (139) 6.5 (165) 8.3 (210) 11.4 (289) 14.0 (356) 14.0 (356) 6.0 (152)
Weight empty (lb/kg) 6.0 (2.7) 8.0 (4) 13.0 (6) 19.0 (9) 27.0 (12) 34.0 (15) 11.0 (5)
Weight full (lb/kg) 13.0 (6) 17.0 (8) 31.0 (14) 56.0 (26) 84.0 (38) 123 (56) 20.0 (9)

F
98
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Vapor Shipment and Liquid Storage Containers

MVE’s Doble Series 2001 Dual Use Tanks


The Doble™ Series tanks from MVE are the first units to be designed for both vapor shipment,
and liquid storage. A unique absorbent layer in the base of the storage tanks enable them
to be charged with nitrogen and employed as dry shippers with hold times of up to 30 days.
Once at the final destination, the tanks can be filled with liquid nitrogen and used for long
term storage.

Features and Benefits


■ Reduce Investment. No need to ■ High Capacity. Reduce the number of
purchase dedicated shipping tanks in shipments with vapor shipments of up
addition to storage units. to 3,500 straws.
■ Optimize Investment. Inventory is ■ Flexibility. The units can be used as a
more flexible, since tanks can be used vapor shipper for export shipment and

1-877-PRAXAIR
for either/or both purposes. simply filled with liquid on arrival, to
■ 40 Years of Technology. The MVE become a high-quality liquid storage
Doble hybrid tanks utilize the same tank for on-site use and resale.
components and vacuum technology ■ Safety and Integrity of Shipment.
which make our current range the The vapor shipping method reduces the
best selling breeder units on the possibility of spillage accidents and in
world market. addition, the unique design of the Doble
■ 3 Year Warranty. Our faith in our pro- units ensures the tank will maintain
temperature for up to 30 days before


duct is your guarantee of performance.
requiring a recharge.
■ Up to 30 Days of Hold Time.

www.praxair.com/specialtygases
Compare to lower cost systems. ■ Simple decontamination.
MVE’s exclusive hydrophobic absorption
■ Rugged Construction. The same
material not only guarantees optimum
durability for shipment and storage –
performance at all times (with no down
no short-term investment, these tanks
time to dry out the tank) but enables
are designed to last on the plane, truck
water-soluble solvents and disinfectants
or farm.
to be used for decontamination.

Specifications
Model Doble-11 Doble-20 Doble-28 Doble-34 Doble-38 Doble-47 Doble-47-10
Part Number* MVE110507886 MVE11492151 MVE11527730 MVE11497948 MVE11521792 MVE11498684 MVE11554308

Maximum Storage Capacity


Number/size of canisters 6/11" 6/11" 6/11" 6/11" 10/11" 6/11" 10/11"
No. of 1/2 cc Straws (10/cane) 480 660 2400 2100 3500 4500 3500

Performance
Liquid Nitrogen Capacity (liters) 10 18.5 28 32 38 46 46
Vapor Capacity (liters) 3.4 3.4 8.4 6.7 10 8.4 9.6
Static Evaporation Rate (liters/day) 0.17 0.1 0.3 0.2 0.4 0.4 0.4
Normal Working Duration (days for liquid) 42 125 50 100 55 74 72
Normal Working Duration (days for vapor) 21 21 24 30 21 21 24

Dimensions
Neck Opening (in/mm) 2.0 (51) 2.18 (53) 3.81 (97) 3.5 (89) 5 (127) 5 (127) 5 (127)
Overall Height (in/mm) 21.6 (549) 25.7 (653) 22 (559) 26.6 (676) 24.5 (622) 26.5 (673) 26.5 (673)
Outside Diameter (in/mm) 10.2 (269) 14.5 (368) 18.2 (462) 18.2 (462) 20 (508) 20 (508) 20 (508)
Canister Height (in/mm) 11 (279) 11 (279) 11 (279) 11 (279) 11 (279) 11 (279) 11 (279)
Canister Diameter (in/mm) 1.5 (38) 1.65 (42) 3.09 (78) 2.81 (71) 2.81 (71) 4 (102) 2.81 (71)
Weight Empty (lb/kg) 19 (8.6) 25.2 (11.5) 34 (15.5) 39.2 (17.8) 45 (20.5) 47 (21.4) 48 (21.8)
Weight Charged (vapor lb/kg) 24 (10.9) 30.2 (13.7) 49 (22.3) 51 (23.2) 59 (26.8) 63 (28.6) 64 (29.1)
Weight Full (liquid lb/kg) 36 (16.4) 60 (27.2) 84 (38.2) 95 (43.2) 105 (47.7) 125 (56.8) 120 (54.5)
# of Cabosil 1 1 2.5 2 3 2.5 3.4
* Part number includes the container and number/size of canisters specified. Note: In order to ensure stated hold time in vapor phase, it is important that the correct
For example: MVE110507886 includes six 11" canisters. charging procedure is followed. The tank must be completely filled with liquid nitrogen for
24 hours prior to use. After 24 hours the excess liquid can be poured off and the unit is
ready for use as a vapor shipper. Patents Pending.
F
99
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Vapor Shippers

MVE’s Vapor Shipper containers are designed for the safe transpor-
tation of biological samples at cryogenic (-150 oC) temperatures.
Fabricated from durable, lightweight aluminum, they contain a hydro-
phobic absorbent that contains the liquid nitrogen. The absorbent
also repels moisture and humidity, assuring the maximum holding
time. A protective shipping carton is available for all models (except
the SC 20/12 V) which protects the container from being placed on
its side and helps in withstanding the rigors of transportation. These
containers can be used to ship your samples with a “non-hazardous”
classification throughout the world, thus reducing costs and helping
to assure sample viability.

Accessories
■ Shipping Carton
www.praxair.com/specialtygases

■ Canisters
■ Spare Corks
A Lightweight aluminum design E Superior hydrophobic absorbent
■ Cryo-Shipper Frame reduces shipping costs – repels moisture and humidity
B All models come with locking while maintaining a -150 oC
tab for shipments chamber environment
C Neck Tube – High strength F Insulation – MVE’s advanced
neck tube reduces liquid insulation system provides
nitrogen loss maximum thermal performance
D Advanced chemical vacuum One model designed and
retention system provides approved to meet IATA and
superior vacuum performance U.N. requirement for the ship-
for the life of the product ment of infectious substances

Specifications
Model SC 2/1V SC 4/2 V SC 4/3V SC 20/12V XC 20/3V(1) Mini Cryo Cryo Cryo
Moover Moover Shipper Shipper XC

Part Number* MVE9922339 MVE9918479 MVE10817330 MVE11005317 MVE11016649 MVE10667790 MVE10647692 MVE10508967 MVE11015195
1-877-PRAXAIR

Maximum Storage Capacity


Number/size of canisters 1/5" 1/11" 1/11" 6/11" 4 + 1 Center 1/11" 7/11" 1 Rack –
No. of 1/2 cc straws - 280 120 540 2,500/2,000* 60 3080 – –
(10/cane)
No. of 1/2 cc straws 88 440 210 780 3,750/3,000* 88 4354 – –
(1 Level Bulk)
Number of 1/4 cc straws 182 938 452 150 750/600* 20 945 – –
(1 Level Bulk)
No. of 1.2 & 2.0 ml vials 9 106 48 180 900/720* 24 1134 500 966 (Bulk)
(6/cane)
Number of blood bag – – – – – – – 10 10
stored (4R9953)

Performance
Liquid nitrogen capacity 1.5 3.6 4.3 12.3 6.8 2.9 4.2 8.5 10
(liters)
Static evaporation rate 0.19 0.26 0.20 0.09 0.3 0.20 0.35 0.85 0.7
(liters/day)**
Static holding time 8 14 21 85 23 14 12 10 14
(days)

Unit Dimensions
Neck opening (in/mm) 1.4 (35) 2.75 (70) 2.0 (51) 2.0 (51) 3.81 (96.7) 1.4 (35) 3.8 (97) 8.5 (216) 8.5 (216)
Overall height (in/mm) 13.5 (343) 18.4 (468) 19.4 (492) 25.7 (652) 25.0 (635) 19.5 (495) 22.0 (558) 21.5 (546) 23 (584)
Outside diameter (in/mm) 7.25 (184) 8.7 (222) 8.7 (222) 14.5 (368) 14.5 (368) 7.2 (184) 18.3 (464) 14.5 (369) 15 (381)
Canister height (in/mm) 5.0 (127) 11.0 (278) 11.0 (278) 11.0 (279) 11.0 (278) 11.0 (278) 11.0 (278) – 12.5 (317.5)***
Canister diameter (in/mm) 1.2 (31) 2.62 (67) 1.81 (46) 1.5 (38) 3.2 (80) 1.2 (31) 3.1 (79) – –
Weight empty (lb/(kg) 6.0 (2.7) 11.0 (5) 13.0 (5.9) 30.0 (13.6) 23.0 (10.5) 8.0 (3.6) 30.5 (13.8) 24.0 (10.9) 30 (13.6)
Weight full (lb/kg) 8.8 (4) 18.0 (8.1) 20.6 (9.3) 52.0 (23.6) 35.0 (15.9) 11.6 (5) 38.0 (17.2) 37.5 (17) 47 (21.4)
(1)
With center absorbent canister (3 week holding time) ** Static evaporation rate and static holding time are nominal. Actual rate and
F * Part number includes the shipper and number/size of canisters specified. holding time will be affected by the nature of container use, atmospheric conditions,
100 For example: MVE9922339 includes one 5" canister. and manufacturing tolerances.
***Useable height
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Extra Capacity – IATA Cryo-Shipper

MVE’s IATA Dewar


The Cryo-Shipper Extra Capacity - IATA Dewar has been indepen-
dently tested and approved to meet current United Nations (UN)
and the International Air Transport Association (IATA) regulations
concerning the transportation of potentially infectious substances.

Specifications
Model Cryo-Shipper Extra Capacity – IATA
Part Number* MVE10777411

Maximum Working Cavity Dimensions 8-1/2" diameter x 8-3/4" deep


IATA Secondary Container Dimensions 7-3/8" diameter x 8-3/4" deep

Maximum Storage Capacity

1-877-PRAXAIR
Number of secondary containers 1
Number of 1 ml vials 450 (5 level bulk)
Number of 2 ml vials 350 (4 level bulk)
Number of 3 ml vials 250 (3 level bulk)
Number of 4 ml vials 250 (3 level bulk)
Number of blood bags stored (4R9951) 22

Performance
Liquid nitrogen capacity (liters) 11.8
Static evaporation rate (liters/day) 0.80


Static holding time (days) 14
Required Accessories – IATA approved shipping vials

www.praxair.com/specialtygases
Unit Dimensions
Neck opening (in/mm) 8.5 (216) Part Number Description
Overall height (in/mm) 24.0 (610) MVE10778810 1 ml (100 vials)
Outside diameter (in/mm) 15.0 (381) MVE10778828 2 ml (100 vials)
Weight empty (lb/kg) 29.0 (13.1) MVE10778836 3 ml (100 vials)
Weight full (lb/kg) 50.5 (22.9) MVE10777438 4 ml (100 vials)
* Includes the Cryo-Shipper Extra Capacity-VSS (MVE9921809), a protective MVE10777446 IATA approved absorbent cloth
shipping carton (MVE10741726), and a secondary container (MVE10862106). (100 sheets per bag)

Cryo-Shipper Mini

MVE’s Cryo-Shipper Mini


The unique cryo-block inserts enable the user to optimize hold time
and capacity. Available in three sizes 1, 1.5, and 2 inches each pair
of blocks provides a specific hold time between 2 and 8 days.

Specifications
Model Cryo-Shipper Mini
Part Number MVE11037386

Performance
Liquid nitrogen capacity (liters) 5.9
Static evaporation rate (liters/day) 0.84
Static holding time (days) 7

Unit Dimensions
Neck opening (in/mm) 8.5 (216)
Overall height (in/mm) 20.0 (508)
Outside diameter (in/mm) 11.63 (295)
Weight empty (lb/kg) 16.5 (7.5)
Weight full (lb/kg) 34.25 (15.6)

F
101
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Control Rate Freezer

Planer Kryo 560


The Planer Kryo 560 is a 16-fully featured tissue bank freezer for
cryopreservation of bone marrow, stem cells, skin, cord blood and
other critical high volume samples.

Features and Benefits


■ Designed for freezing of ■ Unique forced laminar flow
samples in bags, ampoules system ensures efficient,
and straws. even cooling.
■ Controller displays demand, ■ Standard operating features:
sample and chamber tem- ■ Start above ambient
peratures, program stage and ■ Controlled heating

current temperature graphic. ■ Data printing


www.praxair.com/specialtygases

■ Menu driven controller, simple (integral printer)


to program and operate. ■ Port for PC connection

■ Fast cooling rates


■ Protocol stage trigger on
■ Multiple safety features
sample or chamber tempera-
ture or time.

Specification Overview System Specifications


■ Chamber Volume ■ Lower Temperature Limit ■ Range ■ Storage Temperature
16 liters -180 oC 86 oF to -292 oF 14 oF to 158 oF
■ Capacity ■ Cooling Rates (+30.0 oC to -180 oC) (-10 oC to +50 oC)
11 x 250/500 ml bags, -0.01 to -50 oC/Min ■ Heating Rates ■ Storage Humidity
horizontally or vertically ■ Controlled Heating Rates 0.01 oC/min to 10 oC/min 5% to 95% relative humidity
in chamber 0.01 to 10 oC/Min ■ Cooling Rates non-condensing.
■ Ampoule Capacity ■ System Controller: MRV -0.01 oC/min to -50 oC/min ■ Operating Temperature
726 x 2 ml in baskets ■ Accuracy 41 oF to 104 oF
■ System Pump: LNP4 (5 oC to +40 oC)

o
■ Straw Capacity ± (0.3 + 0.005 x TM) C
608 x 2 ml on canes ■ System Dewar: LAB 30 (where TM is the magnitude ■ Operating Humidity
1-877-PRAXAIR

(horizontal) ■ PC Software: Delta T of the temperature). 5% to 90% relative humidity


non-condensing

Controller Specifications Chamber Specifications


■ Dimensions ■ Keypad ■ Weight ■ 50ml blood bags
3.2" H x 8.7" W x 13.8" D 20 key membrane keypad 50 lb (23 kg) 22
(80 x 220 x 350 mm) ■ Programmable Cooling ■ Capacity ■ 250ml blood bags
■ Weight Rate Range 16 liters 11
5.7 lb (2.6 kg) approximate -0.01 oC/min to -99.9 oC/min. ■ Chamber Dimensions ■ 500ml blood bags
■ Display ■ Number of Profiles 13.8" H x 58.4" W x 58.4" D 11
240 x 64 LCD with 10 (350 x 230 x 230 mm) ■ Power Requirements
CCFL backlight ■ Steps per Profile ■ 0.25ml straws (Includes MRV Controller)
■ Printer 32 608 horizontal, 250 vertical 115 V ~ 50/60 Hz
320/640 dot thermal printer ■ Number of Stored Runs ■ 0.5ml straws 1500 VA/230 V ~ 50/60 Hz
5 608 1500 VA

■ 2ml ampoules
726

Ordering Information
Please contact your local Praxair representative for part numbers and pricing.

F
102
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Control Rate Freezer

Planer Kryo 750-30


The Planer Kryo 750-30 is a flexible cryosystem designed for freezing
bone marrow, stem cells, pharmaceutical cell lines, skin, cord blood
and other critical samples in high volumes.

Features and Benefits


■ Designed for freezing of ■ Top or front opening for
samples in bags, ampoules easy loading.
and straws. ■ Heated door seal prevents
■ Unique 2 button operation. freezing shut at cryogenic
■ Standard PC software temperatures.
enables password protected ■ Inner chamber removable
multiple protocols. for sterilization.

1-877-PRAXAIR
■ Protocol stage trigger on ■ Standard operating features:
sample or chamber temper- ■ Start above ambient

ature, or time. ■ Controlled heating


■ Port for PC connection
■ Unique forced laminar flow
■ Fast cooling rates
cooling system ensures most
efficient, even cooling.

Specification Overview


■ Chamber Volume ■ Ampoule Capacity ■ Cooling Rates ■ System Pump

www.praxair.com/specialtygases
29 liters 1452 x 2 ml -0.1 to -50 oC/min Cylinder
■ Capacity ■ Straw Capacity ■ Controlled Heating Rates ■ System Dewar
20 x 250/500 ml blood bags, 1216 x 2 ml 0.1 to 10 oC/min N/A
horizontally/vertically in ■ Lower Temperature Limit ■ System Controller ■ PC Software
chamber, or 40 x 50 ml blood -256 oF (-160 oC) Integral Delta T
bags, horizontally/vertically
in chamber

System Specifications
■ Dimensions ■ Dimensions
Front Loading External Internal Top Loading External Internal
Height 21.6" (55 cm) 10.2" (26 cm) Height 18.9" (48 cm) 9.8" (25 cm)
Width 31.1" (79 cm) 18.3" (46.5 cm) Width 31.1" (79 cm) 18.3" (46.5 cm)
Depth 18.9" (48 cm) 9.8" (25 cm) Depth 21.6" (55 cm) 10.2" (26 cm)

■ Weight ■ Heater ■ Programmable Cooling ■ Recorder Scaling


99 lb (45 kg) (including 1000 W Rate Range OV = -200 oC, +5V = +100 oC
o o
packaging) approximate ■ Sensors -0.01 C/min to -99.9 C/min ■ Standards
■ Capacity Control and sample: ■ Operating Positions Designed to comply with
■ 1452 x 2 ml ampoules, or 4-wire Platinum resistance ther- Vertical or horizontal BSEN 61010,
1216 x 0.5 ml straws mometer. Sensors are linearised in ■ Thermal Cutout CSA22.2 No.125-M1984,
(horizontal or vertical), or software to international standards 120 oC cutout CSA22.2No.151-M1986,
■ 1216 x 0.25 ml straws that utilize a 4096-point lookup EN50082-2, EN50081-2
(horizontal or vertical), or table based on BS1904:1984 ■ Power
103-126VAC 50/60Hz 1200VA ■ Storage Temperature
■ 40 x 50 ml blood bags, or Table 1. Calibration facility 14 oF to 158 oF
■ 20 x 250 ml blood bags, or provided (max.) (470VA freezing only,
with seal and bearing heaters (-10 oC to +70 oC)
■ 20 x 500 ml blood bags ■ Accuracy operating). ■ Storage Humidity
■ Circulation ±0.5 oC at a hold at 0 oC 207-253VAC 50Hz 1200VA Up to 95% non-condensing
Horizontal laminar flow (dynamic accuracy depends (max.) (470VA freezing only,
on actual program, i.e., rate ■ Operating Temperature
■ Temperature Range with seal and bearing heaters 41 oF to 104 oF
o
+212 F to -256 F o of change of temperature) operating). The freezer may be (5 oC to +40 oC)
(+100 oC to -160 oC) ■ Heating Rates damaged by voltage surges in
0.01 oC/min to 10 oC/min excess of 15% above nominal ■ Operating Humidity
■ Cooling Medium Less than 90%
Liquid Nitrogen 22 ± 2 psi ■ Cooling Rates ■ Chart Sensitivity
-0.01 oC/min to -10 oC/min 16.7mV/oC
Nominal impedance >10K
F
Ordering Information 103
Please contact your local Praxair representative for part numbers and pricing.
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Liquid Level Controller

Praxair Replacement Liquid Level Controller


The Praxair Replacement Liquid Level Controller provides accurate control of liquid nitrogen
levels in cryogenic refrigerators. This unit can be substituted as a drop in replacement for
older controls in existing refrigerators. All system components are built to fit in all sizes of
cryogenic refrigerators.
The controller utilizes time proven thermistor based level sensing technology. The level of
the liquid nitrogen is maintained between the 2nd and 3rd sensor pods. The first sensor pod
provides a Low Level Alarm and the 4th sensor pod provides a High Level Alarm. The control
continuously monitors the status of the system including liquid level, temperature, system
events, and alarms. All information is displayed on a 2-line liquid crystal display. All data on
temperature, system events, and alarms is sent to the RS-232 serial port and is also recorded
in battery backed memory on the controller. The controller provides audible, visual and remote
alarm relay for all alarms.
www.praxair.com/specialtygases

Features and Benefits


■ 24 volt AC Power –
■ Error logging – Provides audit record ■ Quick-Chill – Opens the solenoid valve
No UL approval required. Safe. for any errors that have occurred in for a user selectable amount of time
■ User friendly menu system – Provides the system when the lid is closed. This cools the
front panel access to control settings ■ System logging – Provides audit record freezer more quickly. (For units with a
■ Thermistor-based liquid level sensing –
of any system events that have occurred lid switch)
Time proven reliable method in the system ■ Remote alarm relay output – A relay
■ Temperature monitoring – Provides
■ Defog – Opens the solenoid valve for a closure occurs if an error lasts for
temperature display on the front panel user selectable amount of time to clear 30 minutes
■ Temperature logging – Provides audit the fog when the lid is opened. ■ Temperature recorder output – A signal
record of temperatures in the freezer (For units with a lid switch) of 10 mV per 1 oC is provided for a
at user determined intervalsand stores ■ Serial output – Provides capability to chart recorder
the data in internal memory download data to a printer or a computer ■ 2-year warranty

Ordering Information Optional Equipment


Part Number Description ■ Battery backup option – Provides battery ■ External mount box – Can be used for

PCR2LSYS Replacement Level Controller power to operate the control system. The bigger freezers or mounting control away
1-877-PRAXAIR

control can run 3-7 days in battery power mode. from the freezer.

Automated Liquid Nitrogen Supply Tank Switcher

The new MVE® Tank Switch enables two liquid nitrogen supply tanks to be connected to
one or more cryogenic freezers. When the primary supply cylinder is exhausted, the switch
automatically selects liquid delivery from the auxiliary cylinder and warns the user that the
primary cylinder requires replacement.
This unattended switching ensures that supply integrity is maintained to the storage system.
A visual alarm shows when the primary tank has been switched. Audible and visual alarms
indicate to laboratory personnel when both tanks are empty.
The tank switch operates by monitoring pressure in the transfer line, indicating both the
demand for and supply of liquid cryogen. This method eliminates the necessity for hard-
wired electrical connections to the cryogenic freezer control system avoiding the potential
for electrical interference within the freezer control system. This method of operation also
ensures a simple installation. Although designed primarily for cryogenic freezers, the tank
switch can be utilized to supply any device using liquid nitrogen at low pressure and at a
rate similar to liquid nitrogen freezers.

Features and Benefits


■ Automatic, unattended switching ■ Maximizes usage of liquid nitrogen –
between two supply tanks. primary cylinder only needs to be
■ Audible and visual alarm modes. replaced when empty.
■ Simple installation with no hard wire ■ Backup tank increases sample security. Ordering Information
F
connections to freezer unit. ■ Remote monitoring via contact closure Part Number Description
104
notification (NC/NO).
MVE11207040 Auto LN2 Switcher
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Accessories

Boxes are available for all racks.


Part Number Description
MVE9719649 Plastic 2" 100 Cell
MVE9719629 Plastic 2" 25 Cell
MVE9719659 Plastic 3" 100 Cell
MVE9719639 Plastic 3" 25 Cell
MVE9714099 Cardboard 2" 81 Cell
MVE9714109 Cardboard 3" 81 Cell

1-877-PRAXAIR
Inventory Racks

Inventory storage racks are available for liquid nitrogen freezers


from all suppliers. Manufactured from either stainless steel or
aluminum the racks are built to last.
Part Number Description Material Configuration


MVE10544301 7-3 Rack Aluminum 100/81 Cell
MVE10544343 8-3 Rack Aluminum 100/81 Cell Many systems are available for the storage of blood bags – for

www.praxair.com/specialtygases
MVE10544407 11-2 Rack Aluminum 100/81 Cell more information please contact your local Praxair representa-
tive. Cane storage is effected using SUC – 1 boxes.
MVE10544423 12-2 Rack Aluminum 100/81 Cell
Part Number Description
MVE10544440 13-2 Rack Aluminum 100/81 Cell
MVE9710491 SUC Box (2.5" x 2.5" x 11")
MVE10544298 7-3 Rack Stainless 100/81 Cell
MVE10544335 8-3 Rack Stainless 100/81 Cell
MVE10544394 11-2 Rack Stainless 100/81 Cell
MVE10544415 12-2 Rack Stainless 100/81 Cell
MVE10544431 13-2 Rack Stainless 100/81 Cell
MVE10544554 7-3 Rack Aluminum 25 Cell Mini
MVE10544597 8-3 Rack Aluminum 25 Cell Mini
MVE10544651 11-2 Rack Aluminum 25 Cell Mini
MVE10544677 12-2 Rack Aluminum 25 Cell Mini
MVE10544693 13-2 Rack Aluminum 25 Cell Mini
MVE10544546 7-3 Rack Stainless 25 Cell Mini
MVE10544589 8-3 Rack Stainless 25 Cell Mini
MVE10544642 11-2 Rack Stainless 25 Cell Mini Canes
MVE10544669 12-2 Rack Stainless 25 Cell Mini
MVE10544685 13-2 Rack Stainless 25 Cell Mini

Accessories for cane storage.

Platforms are available for vapor phase storage. These raise Part Number Description
the stored racks 6 inches above the base of the freezer. MVE9717009 Cane for 1ml vials (6 per cane)
Part Number Freezer Size (ID) Part Number Freezer Size (ID) MVE9717029 Cane for 1.2ml vials (6 per cane)
MVE10544837 16 inch MVE10544888 31 inch MVE9717089 Cane for 2 ml vials (5 per cane)
MVE10544853 21 inch MVE10544909 39 inch MVE9710899 Cane sleeve to protect vials (box 100)

Please see
liquid transfer hoses, F
page F107 105
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Accessories

The Cryoclaw is designed for easy retrieval of samples Phase separators enable liquid to be dispensed into
www.praxair.com/specialtygases

which have fallen loose into liquid nitrogen. non-pressurized environments with less chance of splashing.
Part Number Description Part Number Description
MVE11068705 Cryoclaw MVE10615869 Phase separator 1-5/8" diameter x 4" long
MVE10615877 Phase separator 1-5/16" diameter x 3" long
MVE10615885 Phase separator 1-11/16" diameter x 1-1/2" long
Dippers are available for simple transfer of liquid from MVE10784443 T piece valve assembly
dewars to point of use.
Part Number Description
MVE9711569 Rigid Dipper 15" Handle Vacuum insulated transfer dewars can be used for
MVE9711589 Rigid Dipper 18" Handle transporting small quantities of LN2 or for work
MVE9711619 Rigid Dipper 19" Handle where a small reservoir of LN2 is required on the bench.

MVE9711669 Rigid Dipper 28" Handle Part Number Description

MVE9711679 Swivel Dipper MVE11014070 Stainless 5 Liter Transfer Vessel


MVE11048940 Stainless 2.5 Liter Transfer Vessel

MVE11053301 Stainless 1.5 Liter Transfer Vessel


MVE11066283 Basket
1-877-PRAXAIR

Open stainless steel dewars are also available as custom in virtually any size.
Please contact your local Praxair representative for details.

Face Shield
FIBF-400
Safety Equipment with clear
Part Number Description window
MVE9717119 Cryo gloves midarm medium
MVE9717129 Cryo gloves midarm large
MVE9717139 Cryo gloves midarm extra large
MVE9717149 Cryo gloves elbow length medium
MVE9717159 Cryo gloves elbow length large
High Performance Face Shield Headgear and Window*
MVE9717169 Cryo gloves elbow length extra large
Part Number Description
MVE10464394 Cryo Apron
FIBF-400 Standard 3-C headgear
Part Number Size Color
FIB4178 CLR 8" W x 16 1/2" H window Clear
FIB4199 CLR 9-3/4" W x 19" H window Clear
* Face shield headgear and window must be ordered separately.

F
106
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Cryogenic Transfer Hoses

All-Stainless Steel Liquid Transfer Hoses


Offering Outstanding Flexibility, Performance,
Safety, and Service Life
Liquid transfer hoses are designed to be highly flexible in cryogenic
applications. Constructed with close pitch stainless steel corrugated
bore, specially woven stainless steel braid, and exterior floppy armor
casing. ISO 10380 certified for bend cycle life. Available with machi-
ned stainless steel tube ends and flares for CGA 295 inert applica-
tions and CGA 440 oxygen applications. Options include 3/8" MPT
one end.

Features
■ Type 321 stainless steel - 4.8 inch dynamic bend radius Designed to be highly flexible

1-877-PRAXAIR
■ 1,160 psi working pressure - 6,104 psi burst pressure in cryogenic applications
■ T-321 stainless steel core
■ Special stainless steel braid
■ Stainless steel armor casing for safety
■ Stainless steel flare or NPT ends
■ Cleaned and bagged to CGA standards
■ Standard lengths are 36" and 72". Custom lengths Stainless steel


available upon request cryogenic elbows

www.praxair.com/specialtygases
Option
■ Stainless Steel Cryogenic Elbows
Long radius design relieves bending stress on hose

Ordering Information
Part Number Description
UNSUF21-IN3 Inert service, 3 ft – CGA 295 each end
UNSUF21-IN3NP Inert Service, 3 ft – 3/8" MPT one end
UNSUF21-IN6 Inert Service, 6 ft – CGA 295 each end
UNSUF21-IN6NP Inert Service, 6 ft – 3/8" MPT one end
UNSUF21-OX3 Oxygen Service, 3 ft – CGA 440 each end
Custom lengths are
UNSUF21-OX3NP Oxygen service, 3 ft – 3/8" MPT one end available upon request
UNSUF21-OX6 Oxygen Service, 6 ft – CGA 440 each end
UNSUF21-OX6NP Oxygen service, 3 ft – 3/8" MPT one end
Note: Standard lengths are 36" and 72". Custom lengths are available
upon request. Specify length with part number (Example UNSUF21-OX3)

Optional Equipment
Part Number Option Description
UNSSSL-CR90-8 SS Cryogenic Elbows 1/2" Tube,
CGA 295 M x F ends
UNSSSL-CR90-10 SS Cryogenic Elbows 5/8" Tube,
CGA 440 M x F ends

F
107
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Dry Ice ThermoSafe™ Storage Containers

Non-electrical low temperature maintenance for a wide variety of laboratory and


field applications. Ideal for demanding cryogenic and laboratory testing as well as
for the transporting and storage of temperature sensitive specimens.

Model 301 – 3.75 cu ft Model 450 – Model 390 – 1.2 cu ft – meets Model 309 – Model 422 – 0.7 cu ft –
www.praxair.com/specialtygases

shown with optional dolly 1.8 cu ft WHO/UNICEF standard E4/CB4 1.0 cu ft bench-top dry ice keeper
for short range vaccine

Specifications/Ordering Information
Model/Part Number PPA301 PPA450 PPA390 PPA309 PPA422
Volume 3.75 cu. ft. 1.8 cu. ft. 1.2 cu. ft. 1.0 cu. ft. 0.7 cu. ft.
Dry Ice Capacity* 235 lb 90 lb 100 lb 54 lb 50 lb
Average Holding Time 15 days 6 days 22 days 5.5 days 10 days
Wall Thickness 2 in 2 in 2 1/4 in 2 in 1-3/4 in
Dimensions ID (in) 22-13/16 x 13-1/2 x 21 15 x 14 x 15-1/4 16-11/16 x 10-1/4 x 12-1/16 12 x 12 x 11-1/2 11-5/16 x 10-3/8 x 10-5/8
Dimensions OD (in) 28-1/8 x 19-1/8 x 25-1/4 18-1/4 x 16-13/16 x 18-3/4 21-5/16 x 14-7/8 x 13-13/16 16 x 16 x 15-1/2 15 x 14-1/16 x 13-3/8
Empty Weight 39 lb 22 lb 22 lb 7 lb 10 lb
Construction Polyethylene casing Polyethylene casing Polyethylene casing Laminated fiberboard Polyethylene casing
with urethane foam with urethane foam with urethane foam exterior and EPS with urethane foam
insulation insulation insulation foam interior insulation
Hardware Lid hinge with stay Lid hinge with stay and Lid hinge with stay Carrying strap – N/A
and 2 latches 2 latches; 2 spring loaded and 2 latches; No handles

handles carrying handle


Accessories Dolly (Model PPA376) N/A Stacking Basket N/A Carrying strap
1-877-PRAXAIR

Stacking Basket (Model PPA378) (Model PPA385)


(Model PPA378)
* Weight calculated using pelletized dry ice.

Electronic Temperature Data Loggers

■ Ensure peace of mind by electronically


recording the temperature profile of
every shipment
■ Reads in degrees Fahrenheit, Celsius,
or Kelvin.
■ High and low time/temperature alarm
with LED indicator
■ Precision thermistor temperature sensor
■ Long-life lithium battery
■ Reporting software available
■ Measures just 3.4 x 1.97 x 0.63 inches, EDL – Reusable, -40 o to +160 oF CTMPDLT – Single use (7 or 30 day),
weighs only 1.85 ounces temperature range -114 o to +86 oF temperature range

Ordering Information Comments


Model/Part Number PPAEDL PPA2CTMPDLT7 Required: Model PPAEDLSOFT reporting
Type Reusable; 17 hours to 360+ days Single use; 7 day software; Model PPAEDLCABL
Data Storage 32,000 readings; programmable 7,800 readings; fixed intervals serial cable
interval 2 sec to 30 min Optional: Model PPAEDLSP16
Range -40 oF to +160 oF (-40 oC to +72 oC) -40 oF to +160 oF (-40 Co to +72 oC) external temperature probe
Accuracy +/- 0.18 oF (0.1 oC) at 68 oF (20 oC) +/- 0.4 oF (0.2 oC) at 68 oF (20 oC) Required: Reporting software and serial cable
F (provided with case pack purchase)
Resolution 0.25 oF (0.1 oC) 0.25 oF (0.1 oC)
108 Spreadsheets Yes Yes Optional: Model PPAEDLSP16 external
Unit per Case 1 20 temperature probe
GAS HANDLING EQUIPMENT
CRYOGENIC PRODUCTS
Dry Ice Machine

Insta Ice™ Dry Ice Machines


Ideal for tissue preservation, specimen shipping, biological manufacturing, industrial
processes, metal fabrication, and classroom demonstrations.
Creates 1 lb dry ice blocks in two minutes or less at your convenience. Simple to
operate – no batteries, accessories, or secondary operations required. Includes every-
thing needed to make uniform, ready-to-use dry ice blocks except the CO2 supply.
Required cylinders of liquid CO2, complete with siphon, are readily available from
Praxair. Built-in safety valve automatically vents excess gas pressure. One year
warranty on all parts.

Ordering Information and Specifications


■ Part Number ■ Dry Ice Block

1-877-PRAXAIR
PPA460 Dimensions: 3 x 1 7/8 x 7 in
■ Yield from 50-lb CO2 cylinder Weight: 1 lb ±10%
9-11 blocks ■ Insta-Ice machine
Dimensions: 4 -3/4 x 4-3/4 x 8-1/2 in
Weight: 5 lb

Comments
■ A 50-lb CO2 cylinder at room temperature contains approximately 42-43 lbs. of usable


liquid CO2. The balance is vapor that does not convert to solid dry ice.

www.praxair.com/specialtygases
■ Maximum yield of solid dry ice can be obtained from 320 lb liquid CO2 cylinders.
This size is generally more economical and provides optimum dry ice production.
Yield can be significantly increased at lower temperatures (e.g., at 0 oF, approximately
1/3 more blocks will be produced).

CO2 Snow Horn

CO2 Snow Horn


The WIL 100 snow horn, hose and pistol grip valve provides a convenient way to obtain
CO2 snow using either a high pressure CO2 siphon cylinder or a liquid cylinder designed
for liquid withdrawal. The standard assembly comes complete with a CGA 320 nut and
gland and supply of Teflon® washers for easy connection to a siphon CO2 or liquid cyl-
inder complete with liquid withdrawal. The six-foot flexible hose is stainless steel con-
struction and the pistol grip valve is brass construction covered with plastic grips. The
valve automatically shuts off when the trigger is released. The assembly incorporates a
1500 psig safety relief valve in the event CO2 liquid is trapped in the hose.

Features
■ High-flow snow horn ■ All metal parts are stainless steel and
■ Pistol grip valve with auto shutoff brass construction
■ Safety relief valve

Specifications
■ CGA 320 brass connections ■ 3/8' inlet 1/4" outlet pistol grip valve
■ 6' x 1/4" braided stainless steel hose rated at 4000 psig
■ 24" plastic snow horn ■ 1500 psig safety relief valve

Ordering Information
Part Number Description
WIL100 Pistol grip snow horn, with stainless steel flex hose assembly F
WIL102 Low velocity replacement horn for the WIL 100 109
GAS HANDLING EQUIPMENT
ACCESSORIES
Diaphragm Valves

533 Series Diaphragm Valves


The 533 Series diaphragm valves are ideal for use as the primary 533 Series
flow control in high purity or corrosive gas systems. Springless Diaphragm
design and low wetted surface area combine to minimize particle Valve
generation and the completely swept path minimizes entrapment.
The unique design of the 533 Series allows low torque operation
with gas flow in either direction. Flow control is accomplished
with the multi-turn model while the 1/4 turn model is quick acting
and indicates on/off position.

Specifications Materials
■ Maximum Inlet Pressure ■ Helium Leak Integrity ■ Bodies and Fittings ■ Seats
5500 psig (240 bar) 1 x 10-8 scc/sec Brass barstock or KEL-F®
www.praxair.com/specialtygases

■ Temperature Range ■ Cv 316L stainless steel ■ Seals


-40 oF to 140 oF 0.17 ■ Diaphragms Metal to metal
(-40 oC to 60 oC) ■ Weight Elgiloy®
0.66 lb (0.3 kg)

Ordering Information – Series CON533ABC


A B C
Flow Control Material Inlet Connections
0: Multi-Turn 2: Brass 0: 1/4" FPT x 1/4" FPT
1: 1/4 Turn 4: 316L Stainless Steel 2: 1/4" Tube x 1/4" Tube
9: Chrome-Plated Brass 3: 1/4" MPT (Extended Leg) x 1/4" Tube
4: 1/4" MPT x 1/4" MPT
8: 1/4" MPT (Extended Leg) x 1/4" Tube
9: 1/4" MPT (Extended Leg) x 1/4" FPT
For example, a CON533140 is a bare body, 316L stainless steel diaphragm valve controlled by a 1/4 turn handle.

1-877-PRAXAIR

Needle Valves Needle Valves

500 Series Miniature Needle Valves


The 500 Series miniature needle valves are forged from brass,
316L stainless steel, or Monel®. They are designed for fine flow
control in a variety of applications in the chemical process and 500 Series
petroleum industries, as well as laboratories and hospitals.
The ground and polished stem and Teflon ® packing make them
suitable for controlling the flow of liquids or gases from vacuum
to 3000 psig.

Specifications Materials
■ Maximum Inlet Pressure ■ Weight ■ Bodies and Fittings ■ Seats
3000 psig (210 bar) 0.7 lb (0.3 kg) Brass barstock or KEL-F®
■ Temperature Range 316L stainless steel ■ Seals
-65 oF to 450 oF ■ Diaphragms Metal to metal
(-54 oC to 232 oC) Elgiloy®

Ordering Information – Series 500


Part Number End Fittings Body Stem Packing
CON5500067 1/4" MPT x 1/4" MPT Forged Chrome-Plated Brass 303 Stainless Steel Teflon®/Chrome-Plated Brass
CON5339002 1/4" MPT x 1/4" MPT Forged Brass 303 Stainless Steel Teflon®/Brass
CON5553225 1/4" MPT x 1/4" MPT Forged Chrome-Plated Brass 303 Stainless Steel Teflon®/Chrome-Plated Brass
F CON5339304 1/4" MPT x 1/4" MPT Forged 316 Stainless Steel 316 Stainless Steel Teflon®/316 Stainless Steel
110 CON5339408 1/4" MPT x 1/4" MPT Forged Monel® Monel ® Teflon®/Monel®
GAS HANDLING EQUIPMENT
ACCESSORIES
Excess Flow Shut-off Valves

Diffusion-Resistant, Diaphragm Seal,


Excess Flow Shut-off Valves (FS Series)
FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the
delivery of gas in a line if the flow exceeds a preset limit. They are commonly used as a
safety device to protect a system from excess flow in the event of equipment failure or to
protect personnel and property in the event of a line rupture. The capability of operating
from 10 to 3500 psi allows them to be used either in high or low pressure applications.
The Excess Flow Limit Valve is a 2-position valve. In the “Open (Reset)” position, the
valve provides a direct passage from inlet to outlet. In the other position, “Auto Shut-Off”,
the valve is set to sense the flow and automatically shuts off the passage if the flow
exceeds a preset value (flow limit). The valve will stay shut-off until it has been reset.
Six flow ranges are offered and the actual flow shut-off value for each range is depen- FS Series
dent upon the operating pressure. The graph below indicates, for each range, the re- Valve

1-877-PRAXAIR
lationship between operating pressure and the actual flow limit. It is suggested that the
range selected provide shut-off at 2-6 times the anticipated flow rate to allow for short
term flow surges not connected with equipment failure.
Note: Piping systems, cylinders and other equipment can contribute rust or other par-
ticulate contamination that could cause the device to fail. Therefore it is highly recom-
mended that all gases be filtered before they enter the FS Series Valve. See Optional
Equipment for additional information .


Standard Features Specifications Flow Range Selection Chart

www.praxair.com/specialtygases
■ Type 316L stainless steel construction ■ Maximum Inlet Pressure
provides maximum corrosion resistance. 3500 psig
■ Elgiloy® diaphragm minimizes diffusion of ■ Minimum Inlet Pressure
air into valve and maintains gas purity. 10 psig
■ High pressure design allows for use ■ Differential Pressure at Flow Limit
between a gas cylinder and the inlet to Ranges A , B, C and D: 5 psig
Ranges E and F: 12 psig
a pressure regulator.
■ Threaded holes on bottom of valve ■ Operating Temperture Range
-10 oF to +150 oF
permit front panel mounting.
■ Inlet and Outlet Connections
1/4" NPT female
Optional Features
■ Approximate Weight
■ High purity inlet filter provides protection 10 oz.
from particulate contamination. ■ Surface Finish
15–20 Ra micro inch or less

Materials
■ Body ■ Seat ■ Spring
Type 316L stainless steel bar stock PCTFE Hastelloy C-22®
■ Bonnet ■ Diaphragm ■ Other Metal Parts Exposed to Gas
Type 316L stainless steel Elgiloy® (or equivalent) Type 316L stainless steel

Ordering Information Optional Equipment


Part Nominal Flow Limit Value for Nominal Flow Limit Value for Part Number Description
Number Nitrogen at 1000 psig Inlet Nitrogen at 30 psig Inlet ADVSG-6113i High purity stainless steel
ADVFS-A 4.8 slpm 0.4 slpm inlet filter (installed)
ADVFS-B 9.1 slpm 1.7 slpm
ADVFS-C 21.8 slpm 3.9 slpm
ADVFS-D 39.5 slpm 9.0 slpm
ADVFS-E 72.3 slpm 14.4 slpm
ADVFS-F 120.6 slpm 22.5 slpm
F
111
GAS HANDLING EQUIPMENT
ACCESSORIES
Ultra-Fine, Low Flow, Metering Valves

Models SG5340, SG5350


Designed for extremely low flow gas and liquid applications, these valves provide smooth,
non-pulsing flow control which is always proportional and absolutely constant at any given
setting. They are particularly suited to the most precise control requirements of gas
chromatography.
Six different needle tapers offer a wide choice of flow ranges (see Ordering Information). Ultra-Fine
Fifteen revolutions of the adjusting handle (“fully opened” to “fully closed”) provide excellent Metering Valve
resolution. The valves will shut off bubble-tight and cannot be damaged by overtightening.
Two models are available. Model SG5340 has a nickel-plated brass body for non-corrosive
service, and model SG5350 has a type 316 stainless steel body for corrosive applications.
These valves are provided standard with mounting nuts for panel mounting applications.

Specifications Materials
www.praxair.com/specialtygases

■ Maximum Operating Pressure ■ Inlet and Outlet Connections ■ Internal Parts Exposed to Gas
Model SG5340: 600 psig at 70 oF 1/8" FPT Model SG5340:
Model SG5350: 1,000 psig at 70 oF ■ Approximate Weight Brass, Delrin® and Stainless Steel
■ Maximum Operating Temperature 5 oz Model SG5350:
Model SG5340: 180 oF Type 316 Stainless Steel and Vespel®
Model SG5350: 250 oF ■ Seals: Viton®

Ordering Information Table 1 – Flow Capacity


Part Number Body Material Needle Taper Flow Flow Capacity (sccm)*
ADVSG5340-( ) Nickel-Plated Brass Number Coefficient (Cv) Helium Air Water
ADVSG5350-( ) Type 316 Stainless Steel 1 0.00029 300 150 4
Where “( )” is indicated above, insert the applicable 2 0.00066 700 350 10
needle taper number from Table 1 to complete the 3 0.0013 1,400 600 20
part number. Example: ADVSG5350-2. 4 0.0057 6,000 2,400 80
5 0.017 18,000 6,800 200

6 0.052 55,000 27,000 650


1-877-PRAXAIR

Miniature Forged Metering Valves

SG5400 Series
These economical valves are used to control gas flow in a wide variety of
applications such as instrument air lines, control panels and gas chroma- Miniature Forged
tography. They are available with either brass or type 316 stainless steel Metering Valve
bodies and have Teflon® packing. Angle Pattern

Specifications Materials
■ Maximum Operating Pressure: 3000 psig ■ Stem
■ Operating Temperature Range Type 316 stainless steel
-65 oF to +165 oF ■ Packing
■ Flow Coefficient: Cv = 0.35 Teflon®

■ Approximate Weight: 5 oz

Ordering Information
Miniature Forged
Brass Body Type 316 Inlet and Outlet Pattern
Part Number Stainless Steel Connections Metering Valve
Body Part Number Straight Pattern
ADVSG5400 — 1/8" MPT Straight
ADVSG5402 — 1/8" MPT Angle
ADVSG5404 ADVSG5424 1/4" MPT Straight
F ADVSG5434 ADVSG5425 1/4" MPT Angle
112 ADVSG5407 ADVSG5427 1/4" compression Straight
GAS HANDLING EQUIPMENT
ACCESSORIES
Check Valves (CV5600 Series)

Check valves ensure that gases or liquids flow in one direction only.
When used on the outlet line of pressure regulators, they prevent
back flow of fluids into the regulator. When used in cylinder pigtails,
they prevent gas flow from one cylinder into another on the same
manifold. They also stop air from entering the pigtail and manifold
when a cylinder is removed.
These check valves are bubble-tight against any back pressure.
Note: Check valves are also available housed within a CGA
connection – see page F116 for additional information.

Specifications Materials
1/4" Compression 1/4" FPT
■ Approximate Weight ■ Spring/Poppet
4 oz Type 316 Stainless Steel Check Valve Check Valve

Ordering Information

1-877-PRAXAIR
Part Maximum Operating Cracking Connections Body Seal Flow
Number Pressure (psig) Pressure (psig) Inlet Outlet Material Material Coefficient (Cv)
ADVCV5651 3000 1.0 1/4" NPT male 1/4" NPT male Brass Viton® 0.5
ADVCV5652 3000 1.0 1/4" NPT female 1/4" NPT female Brass Viton® 0.5
ADVCV5653 3000 1.0 1/4" compression 1/4" compression Brass Viton® 0.5
ADVCV5654 3000 5.0 1/4" NPT male 1/4" NPT female Brass Viton® 0.5
ADVCV5660 6000 1.0 1/4" NPT male 1/4" NPT male 316 SS Buna-N ® 0.5
ADVCV5661 6000 1.0 1/4" NPT male 1/4" NPT male 316 SS Viton® 0.5


ADVCV5663 6000 1.0 1/4" NPT female 1/4" NPT female 316 SS Viton® 0.5
ADVCV5665 6000 1.0 1/4" NPT female 1/4" NPT female 316 SS Buna-N ® 0.5

www.praxair.com/specialtygases
ADVCV5666 6000 1.0 1/4" compression 1/4" compression 316 SS Viton® 0.5
ADVCV5667 3000 1.0 1/4" compression 1/4" compression 316 SS Kalrez® 0.42
ADVCV5668 6000 1.0 1/4" compression 1/4" compression 316 SS Buna-N ® 0.5
ADVCV5669 6000 5.0 1/4" NPT male 1/4" NPT female 316 SS Viton® 0.5
ADVCV5670 3000 1.0 1/4" compression 1/4" NPT male Brass Viton® 0.5
ADVCV5672 6000 1.0 1/4" compression 1/4" NPT male 316 SS Viton® 0.5
ADVCV5674 3000 1.0 1/4" male vacuum* 1/4" male vacuum* 316L SS Viton® 0.36
ADVCV5675 3000 1.0 1/4" male vacuum* 1/4" male vacuum* 316L SS Kalrez® 0.36

Relief Valves (RV5571, RV5572, RV5580 Series)

Relief valves are commonly used downstream of pressure regulators


to protect the regulator, delivery pressure gauge and downstream
system from damage due to overpressurization caused by a regulator
failure. They may be used with hazardous gases because they have
1⁄4" NPT outlets which permits vented gas to be piped to a safe
disposal system.

Specifications
■ Reseat Pressure ■ Outlet Connection
70% of set pressure Model RV5572: 1/4" MPT
■ Inlet Connection ■ Approximate Weight
1⁄4" MPT Model RV5580: RV5571
■ Outlet Connection 8 oz Relief Valve RV5572 RV5580
Models RV5571, RV5580: Models RV5571 and RV5572: Relief Valve Relief Valve
1/4" FPT 2 oz

Ordering Information – Relief valves, adjustable prior to installation Ordering Information – Field adjustable relief valves
Part Adjustable Body Seal Flow Part Adjustable Body Seal Flow
Number Range (psig) Material Material Coefficient (Cv) Number Range Material Material Coefficient (Cv)
ADVRV5571-20 10-20 Brass Viton® 0.37 ADVRV5580-225 10–225 316 SS Viton® 0.60
ADVRV5571-100 20-100 Brass Viton® 0.37 ADVRV5580-350 50–350 316 SS Viton® 0.41
ADVRV5571-250 100-250 Brass Viton® 0.37 ADVRV5580-750 350–750 316 SS Viton® 0.41
ADVRV5571-500 250-500 Brass Viton® 0.37 ADVRV5580-1500 750–1500 316 SS Viton® 0.41
ADVRV5572-50 20-50 Brass Teflon® 0.37 ADVRV5580-2250 1500–2250 316 SS Viton® 0.41
ADVRV5572-100 50-100 Brass Teflon® 0.37 ADVRV5580-3000 2250–3000 316 SS Viton® 0.41
ADVRV5572-250 100-250 Brass Teflon® 0.37 ADVRV5580-4000 3000–4000 316 SS Viton® 0.41 F
ADVRV5572-500 250-500 Brass Teflon® 0.37 ADVRV5580-5000 4000–5000 316 SS Viton® 0.41 113
ADVRV5572-800 500-800 Brass Teflon® 0.37 ADVRV5580-6000 5000–6000 316 SS Viton® 0.41
GAS HANDLING EQUIPMENT
ACCESSORIES
Compression Type Tube Fittings

Compression type tube fittings are the most commonly used in Where compression fitting size is indicated in Ordering Information,
gas handling systems. Suitable for high vacuum and high pressure it designates the outside diameter of the tubing it will accept.
applications, they require no special tools, soldering or welding for For example, 1/8" compression will accept 1/8" OD tubing.
installation, and can be remade repeatedly. Used on thin or heavy
walled tubing, these fittings are available in both brass or Type 316
Stainless Steel.

Part Numbers Description/Tube Fitting Part Numbers Description/Tube Fitting

Brass Type 316 SS Brass Type 316 SS

Male Connector – For connecting Union – For joining tubing


female pipe threads to tubing ADVSG6780 ADVSG6790 1⁄16" compression
ADVSG6705 ADVSG6715 1⁄16" NPT(M) x (both ends)
1⁄8" compression ADVSG6781 ADVSG6791 1⁄8" compression
ADVSG6700 ADVSG6710 1⁄8" NPT(M) x (both ends)
www.praxair.com/specialtygases

1⁄16" compression ADVSG6782 ADVSG6792 1⁄4" compression


ADVSG6701 ADVSG6711 1⁄8" NPT(M) x (both ends)
1⁄8" compression
ADVSG6702 ADVSG6712 1⁄8" NPT(M) x Reducing Union – For joining tubing
1⁄4" compression of different sizes
ADVSG6703 ADVSG6713 1⁄4" NPT(M) x
1⁄8" compression ADVSG6840 ADVSG6850 1⁄8" compression x
ADVSG6704 ADVSG6714 1/4" NPT(M) x 1⁄16" compression
1⁄4" compression ADVSG6841 ADVSG6851 1⁄4" compression x
1⁄8" compression
Female Connector – For connecting
male pipe threads to tubing Bulkhead Union – For connecting
ADVSG6721 ADVSG6731 1⁄8" NPT(F) x tubing through a panel or bulkhead
1⁄8" compression ADVSG6801 ADVSG6811 1⁄8" compression
ADVSG6722 ADVSG6732 1⁄8" NPT(F) x (both ends)
1⁄4" compression ADVSG6802 ADVSG6812 1⁄4" compression
ADVSG6723 ADVSG6733 1⁄4" NPT(F) x (both ends)

1⁄8" compression
ADVSG6724 ADVSG6734 1⁄4" NPT(F) x Union Tee – For joining tubing in
1-877-PRAXAIR

1⁄4" compression “T” configurations

Male Elbow – For connecting female ADVSG6820 ADVSG6830 1⁄8" compression


pipe threads to tubing at right angles (all ends)
ADVSG6821 ADVSG6831 1⁄4" compression
ADVSG6740 ADVSG6750 1⁄8" NPT(M) x (all ends)
1⁄16" compression
ADVSG6741 ADVSG6751 1⁄8" NPT(M) x
1⁄8" compression
ADVSG6742 ADVSG6752 1⁄8" NPT(M) x Reducer – For reducing the size of
1⁄4" compression a compression fitting
ADVSG6743 ADVSG6753 1⁄4" NPT(M) x ADV0202-3027 – 1⁄4" O.D. Tube x
1⁄8" compression 1⁄8" compression
ADVSG6744 ADVSG6754 1⁄4" NPT(M) x
1⁄4" compression
Tube End Male Adapter – For converting
Female Elbow – For connecting male female pipe threads to tubing
pipe threads to tubing at right angles – ADVSG6871 1⁄8" NPT(M) x
ADVSG6761 ADVSG6771 1⁄8" NPT(F) x 1⁄4" O.D. Tube
1⁄8" compression – ADVSG6870 1⁄4" NPT(M) x
ADVSG6762 ADVSG6772 1⁄8" NPT(F) x 1⁄4" O.D. Tube
1⁄4" compression
ADVSG6764 ADVSG6773 1⁄4" NPT(F) x Compression Nut and Ferrule
1⁄8" compression ADVSG6940 ADVSG6950 1⁄16" compression
ADVSG6765 ADVSG6774 1⁄4" NPT(F) x ADVSG6941 ADVSG6951 1⁄8" compression
1⁄4" compression ADVSG6942 ADVSG6952 1⁄4" compression

F
114
GAS HANDLING EQUIPMENT
ACCESSORIES
Pipe Fittings

Pipe fittings are typically used to join components together in a gas The measurements specified in the Tables below conform to
handling system – such as attaching a flowmeter to a regulator, or National Pipe Thread (NPT) designations, and may be either female
installing a relief valve. They are also used in systems which have (internal) type connections, or male (external) type connections –
been constructed using rigid pipe, as opposed to tubing. abbreviated as NPT(F) or NPT(M) accordingly. All pipe fittings
shown have a maximum operating pressure of at least 3000 psig.

Part Number Description/Pipe Fittings Part Number Description/Pipe Fittings

Brass Type 316 SS Brass Type 316 SS

Male Elbow – For joining female Male Hex Nipple – For joining
pipe threads at a right angle female pipe threads
ADV0202-5172 ADV0202-5173 1⁄4" NPT(M) x ADV0202-5186 ADV0202-5187 1⁄8" NPT(M) x
1⁄4" NPT(M) 1⁄8" NPT(M)
ADV0202-5104 – 3⁄8" NPT(M) x ADV0202-5092 ADV0202-5091 1⁄4" NPT(M) x
3⁄8" NPT(M) 1⁄4" NPT(M)

1-877-PRAXAIR
Female Elbow – For joining male Reducing Adapter – Used to
pipe threads at a right angle reduce the size of male pipe thread
ADV0202-5112 ADV0202-5114 1⁄8" NPT(F) x ADV0202-5350 ADV0202-5351 1⁄4" NPT(F) x
1⁄8" NPT(F) 1⁄8" NPT(M)
ADV0202-5113 ADV0202-5115 1⁄4" NPT(F) x
1⁄4" NPT(F) Male Hex Reducing Nipple –
For joining female pipe threads
Street Elbow – For joining female of different dimensions


to male pipe threads at a right angle ADV0202-5185 ADV0202-5108 1⁄4" NPT(M) x

www.praxair.com/specialtygases
ADV0202-5095 ADV0202-5127 1⁄8" NPT(M) x 1⁄8" NPT(M)
1⁄8" NPT(F) ADV0202-5094 – 1⁄2" NPT(M) x
ADV0202-5096 ADV0202-5122 1⁄4" NPT(M) x 1⁄4" NPT(M)
1⁄4" NPT(F)
Male Hex Long Nipple – For joining female
Female Tee – To make a 3-way pipe threads at extended dimensions
connection of male pipe threads – ADV0202-5184 1⁄8" NPT(M) x
ADV0202-4987 ADV0202-4299 1⁄4" NPT(F) x 1⁄8" NPT(M)
1⁄4" NPT(F) x (3" Length)
1⁄4" NPT(F) ADV202-5105 ADV0202-5107 1⁄4" NPT(M) x
1⁄4" NPT(M)
Male Branch Tee – To make a (3" Length)
3-way connection of male by male ADV0202-5106 – 1⁄4" NPT(M) x
by female pipe threads 1/8" NPT(M)
ADV0202-4984 ADV0202-5116 1⁄4" NPT(F) x (3-1⁄2" Length)
1⁄4" NPT(F) x
1⁄4" NPT(M) Female Hex Coupling – To join male
pipe threads
Street Tee – To make a 3-way ADV0202-5182 ADV0202-5183 1⁄8" NPT(F) x
connection of male by female by 1⁄8" NPT(F)
male pipe threads ADV0202-5120 ADV0202-5121 1⁄4" NPT(F) x
ADV0202-5098 – 1⁄8" NPT(F) x 1⁄4" NPT(F)
1⁄8" NPT(M) x ADV0202-5103 – 3⁄8" NPT(F) x
1⁄8" NPT(F) 1⁄4" NPT(F)
ADV0202-5117 ADV0202-5118 1⁄4" NPT(F) x
1⁄4" NPT(M) x Reducing Bushing – Used to
1⁄4" NPT(F) reduce the size of female pipe thread
ADV0202-5181 ADV0202-5102 1⁄4" NPT(M) x
Pipe Cross – To make a 4-way 1⁄8" NPT(F)
connection of male pipe threads ADV0202-5097 ADV0202-5133 1⁄2" NPT(M) x
ADV0202-5188 ADV0202-5190 1⁄8" NPT(F) 1⁄4" NPT(F)
ADV0202-5189 ADV0202-5099 1⁄4" NPT(F)
Pipe Plug (Hollow Hex) – To plug a
female pipe thread
ADV0202-3140 ADV0202-3147 1⁄8" NPT(M)
ADV0202-3143 ADV0202-3023 1⁄4" NPT(M)

F
115
GAS HANDLING EQUIPMENT
ACCESSORIES
Cylinder Connections

Cylinder connections are used for connecting various items of gas handling apparatus
(such as pressure regulators or pigtails) directly to high pressure gas cylinders. The
actual connection varies depending on the gas in the cylinder and is designated by a
three digit code (CGA Connection Number) as set forth in Compressed Gas Association
publication V-1. Cylinder connections consist of a CGA nut and CGA nipple and in some
cases require a washer for sealing purposes.
Praxair offers cylinder connections in a variety of configurations and materials. One
configuration, available in either brass or type 316 stainless steel, features a check valve
housed within the CGA nipple. This configuration restricts flow to only one direction, and
prevents “backflow” from the process to the cylinder.
Also offered are special type 316L stainless steel cylinder connections which end
in a male vacuum-type face seal fitting for use in systems utilizing VCR® or VCR®
compatible type fittings.

Specifications Materials
www.praxair.com/specialtygases

■ Pressure Range Part Number CGA Nipple CGA Nut Check Valve Seat
CGA 347, 680, 695 and 701: ADVSG6650-(CGA) Brass Brass NA
3001–5500 psig ADVSG6650-(CGA)CV Brass Brass EPDM
CGA 677, 702 and 703: ADVSG6651-(CGA) Type 316 Stainless Steel Type 303 Stainless Steel NA
5501–7500 psig ADVSG6651-(CGA)CV Type 316 Stainless Steel Type 303 Stainless Steel Viton®
CGA 290, 510, 678 and 679: ADVSG6651-(CGA)VM Type 316L Stainless Steel Type 303 Stainless Steel NA
0–500 psig ADVSG6652-(CGA) Monel Monel NA
All Others: 0–3000 psig
“(CGA)” shown above indicates that the various CGA connections, listed in the Ordering Information,
are used to make up complete part numbers.

Ordering Information – Brass and Monel


Brass Brass with Check Valve Monel Teflon® Washers
CGA Part Number Outlet Part Number Outlet Part Number Outlet (Package of 25)
Number Connection Connection Connection Part Number
170 ADVSG6650-170* 1/8" NPT male – – – – ADVSG3542
180 ADVSG6650-180 1/8" NPT male – – – – ADVSG3541
320 ADVSG6650-320 1/4" NPT male ADVSG6650-320CV 1/4" NPT male ADVSG6652-320 1/4" NPT male ADVSG6076
326 ADVSG6650-326 1/4" NPT male ADVSG6650-326CV 1/4" NPT male – – –

330 – – – – ADVSG6652-330 1/4" NPT male ADVSG6076


346 ADVSG6650-346 1/4" NPT male ADVSG6650-346CV 1/4" NPT male – – –
1-877-PRAXAIR

350 ADVSG6650-350 1/4" NPT male ADVSG6650-350CV 1/4" NPT male – – –


500 ADVSG6650-500* 1/4" NPT male – – – – –
510 ADVSG6650-510 1/4" NPT male ADVSG6650-510CV 1/4" NPT male – – –
540 ADVSG6650-540 1/4" NPT male ADVSG6650-540CV 1/4" NPT male – – –
580 ADVSG6650-580 1/4" NPT male ADVSG6650-580CV 1/4" NPT male – – –
590 ADVSG6650-590 1/4" NPT male ADVSG6650-590CV 1/4" NPT male – – –
660 ADVSG6650-660 1/4" NPT male – – ADVSG6652-660 1/4" NPT male ADVSG6075
670 – – – – ADVSG6652-670 1/4" NPT male ADVSG6075
* Connection is chrome-plated brass.

Ordering Information – Cylinder Connections (Stainless Steel)


Type 316 Stainless Steel Type 316 SS with Check Valve Type 316L Stainless Steel Teflon Washers
CGA Part Number Outlet Part Number Outlet Part Number Outlet (Package of 25)
Number Connection Connection Connection Part Number
180 ADVSG6651-180 1/8" NPT male – – – – ADVSG3541
320 ADVSG6651-320 1/4" NPT male ADVSG6651-320CV 1/4" NPT male ADVSG6651-320VM 1/4" male Vacuum* ADVSG6076
326 ADVSG6651-326 1/4" NPT male ADVSG6651-326CV 1/4" NPT male ADVSG6651-326VM 1/4" male Vacuum* –
330 ADVSG6651-330 1/4" NPT male ADVSG6651-330CV 1/4" NPT male ADVSG6651-330VM 1/4" male Vacuum* ADVSG6076
346 ADVSG6651-346 1/4" NPT male ADVSG6651-346CV 1/4" NPT male ADVSG6651-346VM 1/4" male Vacuum* –
350 ADVSG6651-350 1/4" NPT male ADVSG6651-350CV 1/4" NPT male ADVSG6651-350VM 1/4" male Vacuum* –
510 ADVSG6651-510 1/4" NPT male ADVSG6651-510CV 1/4" NPT male ADVSG6651-510VM 1/4" male Vacuum* –
540 ADVSG6651-540 1/4" NPT male ADVSG6651-540CV 1/4" NPT male ADVSG6651-540VM 1/4" male Vacuum* –
580 ADVSG6651-580 1/4" NPT male ADVSG6651-580CV 1/4" NPT male ADVSG6651-580VM 1/4" male Vacuum* –
590 ADVSG6651-590 1/4" NPT male ADVSG6651-590CV 1/4" NPT male ADVSG6651-590VM 1/4" male Vacuum* –
660 ADVSG6651-660 1/4" NPT male ADVSG6651-660CV 1/4" NPT male ADVSG6651-660VM 1/4" male Vacuum* ADVSG6075
670 ADVSG6651-670 1/4" NPT male ADVSG6651-670CV 1/4" NPT male ADVSG6651-670VM 1/4" male Vacuum* ADVSG6075
677 ADVSG6651-677 1/4" NPT male ADVSG6651-677CV 1/4" NPT male – – –
678 ADVSG6651-678 1/4" NPT male – – ADVSG6651-678VM 1/4" male Vacuum* ADVSG6077
679 ADVSG6651-679 1/4" NPT male – – ADVSG6651-679VM 1/4" male Vacuum* ADVSG3543**
680 ADVSG6651-680 1/4" NPT male – – – – –
695 ADVSG6651-695 1/4" NPT male – – – – –
702 ADVSG6651-702 1/4" NPT male – – – – –
F 703 ADVSG6651-703 1/4" NPT male – – – – –
116 705 ADVSG6651-705 1/4" NPT male – – – – ADVSG6078
* Connection is compatible with 1/4" VCR® fittings.
** Washers are constructed of lead and can also be used with CGA 110 connections.
GAS HANDLING EQUIPMENT
ACCESSORIES
High Pressure Flexible Hoses

High Pressure Flexible Hoses


316 SS high pressure flexible metal hoses are designed for strong,
safe and flexible operation in demanding specialty gas environ-
ments. Zero permeation characteristics do not allow gas or atmo-
sphere to pass through its wall in either pressure or vacuum applica-
tions. Ideal for flammable, toxic, high purity and small molecule gases.
1/4" Style S (shown with SS Male NPT and Armor Casing)
■ SS core, double SS braid. Style S - 3,850 psi
■ SS core, double SS braid. Style H - 4,800 psi 316L SS 316L SS corrugated inner core.
TIG weld Very close pitch for extreme flexibility,
argon purge high flow, and longer hose life.
Monel® Inner, Stainless Steel Braid
~20 convolutions/inch, 2x the
Monel high pressure flexible metal hoses with SS braid are ideal for industry standard
oxygen service where particle impingement failure is a concern. The
SS braid is more economical and allows higher working pressures

1-877-PRAXAIR
than Monel braid.
■ Monel core, double SS braid. Style M - 4,200 psi
■ Available with Monel or SS fittings.
316L SS One piece 304 SS Double layer of
Armor Casing end fitting weld and casing crimp 304 SS braid –
ferrule for superior 3850 psi working
For hoses that are constantly handled and flexed, armor casing
connection to armor pressure
protects against kinking, braid abrasion or stress at the end fittings.
casing. Reduces stress
The smooth surface also provides additional handling protection for


at weld joint.
operators, plus the capability to support a 600 lb load under tension.

www.praxair.com/specialtygases
Armor casing is protected under a special 3 year limited warranty.

1/4" Style M (shown with Monel Female NPT and SS Armor Casing)
Specifications
Hose Style S H M Monel Smooth Monel 400-series inner core and
TIG weld transition from double braid ~20 convolutions/
Size I.D. (in) 0.285 0.285 0.285 argon purge hose to fitting inch, for extreme flexibility and up
Size O.D. w/o Armor (in) 0.445 0.445 0.445 to twice the hose life. 3000 psi
Size O.D. w/ Armor (in) 0.725 0.725 0.725 working pressure.

Inner Core Wall Thickness 0.010 0.010 0.010


MAWP (psig) 3,850 4,800 4,200
Minimum Burst Pressure (psig) 15,400 19,200 16,800
Minimum Bend Radius w/o Armor (in) 2.5 2.5 2.5
Minimum Bend Radius w/ Armor (in) 2.7 2.7 2.7
Weight Per Foot w/o Armor (lb) 0.29 0.29 0.33 Monel end One piece extra long 304 SS
fitting for superior weld and casing collar interlocked armor
Weight Per Foot w/ Armor (lb) 0.49 0.49 0.53
corrosion eliminates stress at casing fully
Temperature Range (oF) Cryo to Cryo to Cryo to resistance end fitting protects hose
1,500 1,500 1,500
Conductive (Yes/No) Yes Yes Yes

Ordering Information – Series FCOABCDEFGH


A B C D E F G H
Hose Style Fitting Fitting Fitting Material Safety Oxygen CGA Length*
1st End 2nd End Both Ends Option Clean (in)
S 3: 1/4" MPT 3: 1/4" MPT S: 316 SS A: Armor O Specify 18
H 6: 1/4" MPT 6: 1/4" MPT M: Monel ** 24
M 36
* Custom lengths available.
Inquire about our
** M hose style only.
full line of hose styles,
end-fittings, safety and
productivity options available
to meet your specific needs.
F
117
GAS HANDLING EQUIPMENT
ACCESSORIES
Brass Flash Arrestor

Flash arrestor (Model SG6546)


Flash Arrestors are designed to provide protection against flashback of
fuel gas and oxygen. The Model SG6546 Flash Arrestor functions in three
beneficial ways by: stopping gas back-flow, extinguishing flashbacks and
stopping all gas flow to the process at time of activation.
They are commonly installed downstream of regulators and on supply
lines where flammable gases are used. The Model SG6546 meets OSHA
requirements, NFPA codes and is factory mutual approved when used at or Model SG6546
below the maximum service pressures listed below in Ordering Information.

Standard Features Specifications Materials


■ Prevents back flow of gas into regulator or supply line. ■ Flow Coefficient ■ Body
■ Extinguishes flashback within housing and prevents flame 0.07 Brass
from reaching gas supply
www.praxair.com/specialtygases

■ Inlet & Outlet Connections ■ Seat and Seals


■ Stops gas flow at time of activation and eliminates feeding 1/4" FPT Butyl Rubber
gas to any residual sparks or fire. ■ Dimensions ■ Other Metal Parts Exposed
■ Provides minimal gas flow restrictions since there are 2" Max O.D. x 3-1/2" long to Gas
no porous filters to clog. ■ Approximate Weight Brass and Steel
2 lb
Ordering Information
Part Number Gas Service/Maximum Pressure (psig)
ADVSG6546 Acetylene (15), Natural Gas (15), Hydrogen (50),
Propane (50), Oxygen (150)

Stainless Steel Flash Arrestor

Stainless Steel Flash Arrestor (Model SG6547)


The SG6547 Series flash arrestors are designed for oxidizer and flammable
1-877-PRAXAIR

gas applications that require stainless steel construction with Viton®


elastomers. These arrestors are compact in design and provide the following
safety elements when used in a delivery system: 100 micron filtration, reverse
flow check valve, flame barrier and thermal cut-off valve.
Flash arrestors are commonly installed downstream of regulators and on
supply lines. The SG6547-F is designed for fuel gases and the SG6547-O is Model SG6547
designed for use with oxidizer gases. The SG6547 Series flash arrestors are
listed by Underwriter Laboratories to U/L 23Y5 and meet the requirements of
safety standards BAM, EN730 and ISO 5175 Class.

Standard Features Specifications Materials


■ 100 micron stainless steel inlet filter helps prevent contaminants ■ Maximum Service Pressure ■ Body
from blocking check valve and provides extended service life 285 psig. See Ordering 316L Stainless Steel
■ Check valve prevents hazardous back flow of gas into Information for U/L 23Y5 ■ Seat and Seals
standard limits Viton ® (other elastomers
regulator or supply line
■ Flame barrier extinuishes flashback within housing and ■ Inlet Connection available on special order)
prevents flame from reaching gas supply 1/4" FPT ■ Other Metal Parts Exposed
■ Thermal cut-off valve positively shuts off gas flow in the event ■ Outlet Connection to Gas
of downstream fire reaching the flash arrestor. 1/4" MPT Stainless Steel
■ Dimensions
1-1/4" Max O.D. x 3-7/8" long
Ordering Information and U/L 23Y5 Standard Flashback Limits
■ Approximate Weight: 12 oz
Part Number Gas Service Working Pressure (psig)
ADVSG6547-F Acetylene 15
Hydrogen 50 Table 1 – Flow Capacity
LPG 50
Inlet Pressure (psig) 7 14 22 36 73
F ADVSG6547-O Oxygen 145
Air Flow (scfh) 230 465 725 1,040 1,935
118
GAS HANDLING EQUIPMENT
ACCESSORIES
Carbon Dioxide and Nitrous Oxide Gas Heaters (Model SG6500)

Praxair’s model SG6500 gas heater is designed for use with either carbon dioxide or nitrous
oxide to prevent regulator freeze-up under high flow conditions. Installed between the cylinder
valve and a suitable regulator, the heater warms the gas stream allowing for flow rates up to
160 scfh without regulator freeze-up.
The gas heater is thermostatically controlled at 160oF to prevent overheating of the gas.
The heating element, encased in a polymeric body, efficiently radiates heat to the gas stream.
The outer jacket of the heater provides insulation to allow the operator to install or remove
the heater under warm conditions. The Model SG6500 Heater may be used in conjunction SG6500
with any regulator that is suitable for carbon dioxide or nitrous oxide use. Heater

Specifications Materials
■ Maximum Operating Pressure ■ Thermostat Setting ■ Inlet and Outlet Connections
3000 psig 160 oF ±5 oF Brass
■ Voltage: 110 VAC ■ Power Cord Length ■ Other Metal Parts

1-877-PRAXAIR
■ Power 5-1/2 feet Exposed to Gas
120 watts, 1 amp ■ Dimensions (approximate) Brass

■ Maximum Flow Rate 6-1/2" x 2-1/2" x 1-3/4" ■ Heater Block


160 scfh (CO2) ■ Approximate Weight: 2 lb Epoxy, Polymer

Ordering Information
Part Number Gas Service Inlet Connection Outlet Connection


ADVSG6500-320 Carbon Dioxide CGA 320 CGA 320 Adapter*
ADVSG6500-326 Nitrous Oxide CGA 326 CGA 326 Adapter*

www.praxair.com/specialtygases
* Suitable for direct mounting of a pressure regulator with specified CGA.

Electric High Flow Heaters for Compressed Gases (Model SG7500)

Praxair’s model SG7500 electric heater is designed for use with nonflammable liquefied
compressed gases to prevent regulator freeze-up and to assure uniform temperature under
high flow conditions. Connected between the cylinder valve and a suitable regulator, the heater
warms the gas stream allowing for flow rates up to 1000 scfh* (CO2) without regulator freeze-up.
The heater is designed with a dry heat exchange medium made of aluminum and continuous
high pressure stainless steel tubing with no internal joints.

Standard Features Optional Featues


■ Heavily insulated cabinet ■ Flow can be in either direction ■ Manifold adapter block SG7500
remains “cool”. without loss of efficiency. provides means to install Heater
■ Heater can be left on inde- ■ Mounting bracket provides heater between gas cylinder
finitely, even under no-flow for convenient, wall mounted and regulator with CGA
conditions, without resultant installation. connections.
damage. ■ C.S.A. approved

Specifications Materials
■ Maximum Operating Pressure ■ Voltage 120 VAC ■ Tubing: 5/16" O.D. x .049 ■ Inlet and Outlet Connections
3600 psig ■ Power: 1000 watts, 8.3 amps wall x 7 in long Type 316 Stainless Steel
■ Maximum Flow Rate ■ Thermostat Setting ■ Dimensions ■ Tubing
1000 scfh for CO2* 170 oF ±5 oF 11" H x 5-1/2" W x 4-1/4" D Type 304 Stainless Steel
(at initial gas temperature ■ Power Cord ■ Mounting Holes ■ Cabinet
0 oF and 170 oF outlet) 6 ft., 3-wire UL/CSA listed 3 inch O/C Metal enclosure
* Capacities for other gases will vary, ■ Inlet and Outlet Connections ■ Approximate Weight
depending of their specific heat. 1/4" MPT 11 lb

Ordering Information Optional Equipment


Part Number Description Part Number Manifold Block
F
ADVSG7500 SG7500 Electric heater ADV14-SS-320 CGA 320 x CGA 320 adapter
ADV14-SS-326 CGA 326 x CGA 326 adapter 119
ADV14-SS-580 CGA 580 x CGA 580 adapter
GAS HANDLING EQUIPMENT
ACCESSORIES
Regulator Gauges

550 Series Regulator Gauges


These 550 Series regulator gauges allow
you to monitor pressure in systems. They
are available in 2" diameter brass or 316L
stainless for the 400 Series regulators, and
2" chrome-plated brass with or without 316
stainless steel wetted parts for 300 Series
regulators. For the 200 Series regulators
2-1/2" chrome-plated brass gauges
are used.
For convenient mounting 550 Series are
1/4" NPT bottom mount, UL listed, and
cleaned for oxygen service, ANSI B40.1. 2" Inch Gauges 2 1/2" Inch Gauges
www.praxair.com/specialtygases

Ordering Information – Series CON550 Regulator Gauges, 400 Series Regulators


2" Brass 2" Brass 2" Brass 2" 316 SS 2" 316 SS 2" 316 SS
Pressure Range psig/kPa bar/psig Pressure Range psig/kPa bar/psig
30"-0-30 psig CON550-0201 CON550-0300 30"-0-30 psig CON550-0221 CON550-0320
30"-0-100 psig CON550-0202 CON550-0302 30"-0-100 psig CON550-0222 CON550-0322
30"-0-200 psig CON550-0203 CON550-0303 30"-0-200 psig CON550-0223 CON550-0323
0-300 psig CON550-0204 CON550-0304 0-300 psig CON550-0224 CON550-0324
0-400 psig CON550-0205 CON550-0305 0-400 psig CON550-0225 CON550-0325
0-1000 psig CON550-0206 CON550-0306 0-1000 psig CON550-0226 CON550-0326
0-4000 psig CON550-0208 CON550-0308 0-4000 psig CON550-0228 CON550-0328
0-6000 psig CON550-0209 CON550-0309 0-6000 psig CON550-0229 CON550-0329

Ordering Information – Series CON550 Regulator Gauges, 300 Series Regulators


2" Chrome-Plated 2" Chrome-Plated 2" Chrome-Plated 2" Chrome-Plated 2" Chrome-Plated 2" Chrome-Plated
Brass Brass Brass Brass, SS Internals Brass, SS Internals Brass, SS Internals
1-877-PRAXAIR

Pressure Range psig/kPa bar/psig Pressure Range psig/kPa bar/psig


30"-0-30 psig CON550-0267 CON550-0367 30"-0-30 psig CON550-0621 CON550-0720
30"-0-100 psig CON550-0268 CON550-0368 30"-0-100 psig CON550-0622 CON550-0722
30"-0-200 psig CON550-0269 CON550-0369 30"-0-200 psig CON550-0623 CON550-0723
0-300 psig CON550-0273 CON550-0373 0-300 psig CON550-0624 CON550-0724
0-400 psig CON550-0270 CON841-0545 0-400 psig CON550-0625 CON550-0725
0-1000 psig CON550-0271 CON550-0371 0-1000 psig CON550-0626 CON550-0726
0-4000 psig CON550-0263 CON841-0546 0-4000 psig CON550-0628 CON550-0728
0-6000 psig CON550-0272 CON550-0372 0-6000 psig CON550-0629 CON550-0729

Ordering Information – Series CON550 Regulator Gauges, 200 Series Regulators


2-1/2" Chrome-Plated 2-1/2" Chrome-Plated 2-1/2" Chrome-Plated
Brass Brass Brass
Pressure Range psig/kPa bar/psig
0-30 psig CON550-0241 CON550-0291
0-60 psig CON550-0242 CON550-0292
For information on
0-200 psig CON550-0243 CON550-0293
Praxair regulators,
0-400 psig CON550-0245 CON550-0295
please see
0-600 psig CON550-0250 CON550-0299
pages F1 to F34.
0-1000 psig CON550-0246 CON841-0296
0-4000 psig CON550-0248 CON550-0298
0-6000 psig CON550-0249 CON550-0297
0-30 psig (Redline) CON550-0240 CON550-0290
F
120
GAS HANDLING EQUIPMENT
ACCESSORIES
Electronic Cylinder Scale

Accurate and reliable weight measurement


of liquefied process gases enables the gas
measurement system to maintain the high
standards of product purity required by
today’s customer. As gas vapor is with-
drawn from the cylinder, non-volatile im-
purities remain behind in liquid state, which
becomes progressively less pure as the
cylinders contents are depleted. Therefore,
cylinders are routinely changed with some Panel Mount Display
minimum level of product (typically 10-25%
of contents) which is accomplished using
an electronic cylinder scale. Typical pro-
blems associated with reduced reliablility
of present scale designs have been

1-877-PRAXAIR
addressed by this unit.
Issues such as:
■ Signal drift due to thermal hysteresis
from ambient temperature changes
■ RFI/EMI induced signal fluctuations
■ Mechanical failure caused by lateral
Box Mount Display
stresses to the load cell from cylinder


movement

www.praxair.com/specialtygases
Specifications
■ Capacity ■ Repeatability ■ EMI/RFI Immunity
300 lb FS (136 kg) +0.1% FS @ 68 oF (20 oC), C.E. labeled per emission
■ Maximum Overload +0.25% over operating Test spec: EN50081-2 1994 – Heavy
150% FS temperature range Industrial Standard and Immunity Test
■ Long Term Drift-Stability Spec: EN50082-2 1995 – Heavy Industrial
■ Dimensions Standard 10 volts/meter
Height: 1.33" (3.4 cm) +0.25 pounds per 30 days
Platform: 9.25" x 9.25" (+0.08% FS/month) ■ Relative Humidity
(23.5 cm x 23.5 cm) ■ Zero Shift 0-95% R.H. non-condensing

■ Material +0.10 mA per 30 days ■ Electrical Output


Platform: Stainless steel (+0.625% FS/month) 2 wire 4-20 mA
Base: Stainless steel ■ Connections Location ■ Input
Load cell: Stainless steel 10 ft (3 m) pigtail center 12-30 VDC
■ Accuracy rear of platform ■ Zero/Span Port Location
+0.1% FS @ 68 oF (20 oC), ■ Operating Temperature Accessible at front of platform
o o
+0.25% over operating 14 F to 150 F ■ Environmental
temperature range (-10 oC to 65 oC) Water Resistant
(wash down – not submerged)

Ordering Information – Series AUGLCS-ABC


A B C
Pressure Range Output Display
0300: 300 lb (136 kg) B: 4 to 20 mA 0: No Display
0060: 60 lb (27 kg) 1: Panel Mount Display
2: Standard Box Display

Hydraulic cylinder
scales are also
available upon
request

F
121
GAS HANDLING EQUIPMENT
ACCESSORIES
Portable Headspace Analyzer

Food Applications
The 901 Series portable headspace analyzer has proven itself in hundreds of installations for food applications
such as meats, fresh produce, pasta, nuts, snack-foods, dairy products and coffee. The sensor is unaffected
by high levels of background gases such as nitrogen or carbon dioxide. The 901 Series can also be used for
applications where the oxygen level is very high (50 to 100%), without overloading the sensor. It is unaffected
by trace hydrocarbons or high levels of CO 2, which can poison other types of sensors. The 901 Series is a
battery-operated, portable oxygen analyzer used for the measurement of residual oxygen in gas-flushed
(CAP/MAP) food packages. This hand-held unit can be used by non-technical personnel where you need it,
in the lab or at the packaging line, or it can be easily transported to other locations. The 901 Series is powered
by Ni-Cad re-chargeable batteries, which provide 8 hours of operation before recharging is required.
Easy Sampling Analysis
The 901 Series portable headspace analyzer sample probe is tipped with a particulate filter and luer fit syringe
needle with side-port holes to prevent plugging. The sample is drawn through the probe and tubing and then to
the oxygen sensor when the pump is turned on. The pump is electronically timed to draw in the precise amount
of sample required for the analysis, and then turns itself off after the pre-set sampling time (5 to 10 seconds).
The oxygen concentration is read on the display. It is a cost effective, reliable alternative to other analyzers. Not
www.praxair.com/specialtygases

only is the initial cost much lower, but operating and maintenance costs are lower as well. When service is
required, units are generally repaired and returned the same day as received to minimize down-time.
Principle of Operation
The 901 Series uses a syringe needle sampling assembly to pierce the package and draw a sample into the
analyzer sensor for oxygen measurement. The sensor signal is converted to percent concentration and displayed
on the LCD screen. The oxygen sensor used in the 901 Series was specifically designed for gas-flushed pack-
aging measurements. The sensor is a proprietary electrochemical design which is inexpensive, quick to respond,
requires minimal power and has excellent zero and span stability. Unlike zirconia sensors which are heated to
500-600 oC, the 901 analyzer will not crack when exposed to liquid water droplets and is unaffected by trace
hydrocarbon gases.

Specifications Ordering Information


■ Range ■ Battery Life Part Number Description
0.1 to 100% oxygen Eight hours before recharging QUN901 Portable Headspace Analyzer
■ Resolution ■ Size
0.1% Oxygen 8" x 4" x 1.8" Optional Equipment
■ Sample Pump (20 cm x 10 cm x 4.6 cm) Part Number Description

Internal, with adjustable timer ■ Weight QUNCS100 Container Sampler


■ Sensor 1 lb (450 g) QUN9001 Foam Seal Pads
1-877-PRAXAIR

Electrochemical cell ■ Power Supply QUN9003 Package Of Needles, Side Hole


■ Sampling Assembly Rechargeable “AA” (4) bat- QUN9005 QUN Particulate Sample Filters
Probe-male luer connection teries auto shut-off, after 45 QUN9007 QUN Sample Probe Assembly
(side-port needle) PTFE tubing minutes idle. Charger included QUN9024 Operating Manual
QUN9015 Package with Needles, Filters and Foam Seal Pads

Oxygen/Carbon Dioxide Analyzer

The headspace analyzer is used for the analysis of oxygen, carbon dioxide, and combination O2/CO2 headspace
in flexible or rigid packages. It incorporates a new technology which alerts the operator in the event of a blockage
of gas flow from the package to the analyzer. The headspace analyzers are used in production, quality control,
and R & D applications to assess package integrity. This instrument is certified traceable to NIST.

Features
■ Small sample size ■ Flo-Smart™ technology ■ Auto sample pump
■ Fast response time ■ Ease of use ■ Liqui-Blok™ filter

Typical Applications
■ Snack foods ■ Meats and Cheeses ■ Modified atmosphere ■ Coffee, juice and
■ Bakery ■ Pharmaceutical vials and packaging carbonated beverages
pouches ■ Produce

Specifications Ordering Information


■ Sensor – ■ Ambient Operating Temperature Part Number Description
Solid State Zirconium Oxide 41 oF to 104 oF MOC001-198 Auto-Sampling headspace analyzer for measuring O2
■ Internal Sampling Pump or (5 oC to 40 oC)
F Manual Option ■ Range MOC001-253 Auto-Sampling headspace analyzer for measuring CO 2

122 ■ Minimum 2cc Sampling Size Oxygen – 0 ppm to 100% MOC001-114 Auto-Sampling headspace analyzer for measuring O 2/CO2
■ RS 232 Included for Carbon Dioxide – 0% to 100%
Data Collection
GAS HANDLING EQUIPMENT
GAS DETECTION SYSTEMS
Overview

Gas Detection Equipment


In many industrial applications, hazards The DrägerTubes® are specifically calibrated
can have several origins, e.g., the release to the flow characteristics of the Draeger
of toxic gases, oxygen deficiency or enrich- pumps.
ment, as well as the presence of combus-
The Draeger Chip-Measurement-System
tible gases and vapors. When detected at
(CMS) combines an electronic based analy-
an early stage, countermeasures can be
zer with substance specific chips. Designed
initiated to protect personnel, workplaces
for the measurement of more than 50 hazar-
and equipment.
dous gases and vapors in the work place
Praxair, working together with Draeger, pro- environment, the Draeger® CMS™ system
vides a full range of fixed and portable moni- does not require calibration (specific infor-
toring and warning systems, for short- and mation is stored on a bar code on each
long-term measurements, both for area and chip) and a digital display provides the
personal monitoring. measurement results.

1-877-PRAXAIR
Portable Detection Systems Fixed Gas Detection Systems
Draeger offers a wide range of portable gas The DrägerSensor® electrochemical, cata-
Most popular models include:
detection systems, from single to multiple lytic combustion and infrared sensors are
■ Draeger® Polytron™ 2 XP Ex –
gas detectors, using electrochemical cata- the key elements of Draeger’s detector
for combustible gases and vapors
lytic bead and infrared detectors. Draeger’s transmitters and controllers. These intelli-
(page F124)
Pac III™, MiniWarn ™ and Multiwarn II™ moni- gent sensors can transmit information such
■ Draeger® Polytron™ 2 XP Tox –
tors are the most popular. See pages F131- as alarm levels, calibration details, variation


for toxic gases and oxygen deficiency
F133 for details. of gas concentration and temperature.
(page F125)

www.praxair.com/specialtygases
Draeger’s new Accuro® pump is the cor- Draeger’s detectors and analyzers/trans- ■ Draeger® Polytron™ IR CO2 detector –
nerstone of the DrägerTubes® gas detec- mitters are designed to work independently for carbon dioxide (page F127)
tion system (see page F130). Its low-main- and/or feedback information to central ■ Draeger® PointGard® II – for toxic gases
tenance, one-handed operation provides controllers housed in a safe working area. and oxygen deficiency (page F126)
quicker analysis and better accuracy. They can detect over 300 gases using ■ Draeger® QuadGard™ and Regard-1™
DrägerSensor® technology. detector controllers (page F128)

Selected gases detectable with Draeger’s Gas Detection and Monitoring Systems
Gas Formula Gas Formula Gas Formula
Acetylene C2 H2 Ethylene C2H 4 Monomethylamine CH3NH2
Ammonia NH3 Ethylene oxide C2H 4O Nitric oxide NO
Arsine AsH3 Ethylmercaptan C2 H 5 SH Nitrogen dioxide NO2
Boron trichloride BCI3 Fluorine F2 Nitrogen trifluoride NF3
Boron trifluoride BF3 Germanium hydride GeH 4 Organic Vapors OV
Bromine Br2 Germanium tetrafluoride GeF 4 Oxygen O2
Butadiene-1.3 (C2H3) 3 Hydrazine N2H 4 Ozone O3
Butylamine,sec. C4H9NH2 Hydrogen H2 Phosphine PH3
Butylmercaptan,tert. C4H4SH Hydrogen bromide HBr Propylene C3H 6
Carbon dioxide CO2 Hydrogen chloride HCI n-Propylmercaptan C3H 7SH
Carbon monoxide CO Hydrogen cyanide HCN Silane SiH4
Chlorine Cl2 Hydrogen fluoride HF Silicon tetrachloride SiCI4
Chlorine dioxide ClO2 Hydrogen peroxide H2O 2 Silicon tetrafluoride SiF4
Diborane B2H6 Hydrogen sulfide H2S Sulfur Dioxide SO2
Dichlorsilane SiH2CI2 i-Propanol (CH3)2 CHOH Trichlorosilane SiHCI3
Diethylamine (C2H5)2 NH Isopropylamine (CH3)2 CHNH2 Triethylamine (C2H5) 3N
Dimethylamine (CH3)2 NH Isopropylmercaptan (CH3) 2 CHSH Trimethylamine (CH3)3N
Dimethylethylamine (CH3)2 C2H5N Methanol CH3OH Trimethylborane B(CH3)3
Dimethyl sulfide (CH3)2 S Methylmercaptan CH3SH Tungsten hexafluoride WF6
Ethanol C2H5OH Methyl methacrylate C2H2 (CH3 )COOCH3 Vinyl chloride C3H3 Cl
F
For gases not listed above, please contact your Praxair representative. 123
GAS HANDLING EQUIPMENT
GAS DETECTION SYSTEMS
Combustible Gas Detector Transmitter

Draeger® Polytron™ 2 XP Ex Gas Detector Transmitter


The Draeger® Polytron™ 2 XP Ex from Draeger is an explosion proof, catalytic
bead gas detector transmitter for continuous monitoring of combustible gases
and vapors in ambient air. The transmitter uses state-of-the-art microprocessor
technology to convert the signal from a catalytic combustion DrägerSensor ® to
a 4 to 20 mA analog or a HART® or RS485 digital signal output.
The unit is designed for one-man calibration, and offers a variety of diagnostics
and self test features. The configuration and calibration of the transmitter is menu
guided and easy to perform, using either the infrared remote control, the built in
push buttons or a HART® hand held terminal. With the optional on-board relays,
Draeger® Polytron 2 XP Ex can be operated as a ‘stand alone’ unit.

Features and Benefits


www.praxair.com/specialtygases

■ Poison resistant catalytic bead ■ Multidrop capability


■ Fast, accurate response ■ Optional relays on board Draeger® Polytron™ 2 XP Ex
■ DrägerSensor® technology ■ UL, CSA, CENELEC approved Gas Detector Transmitter
■ Backlit LCD Display ■ CE marking
■ 4 to 20 mA analog, HART® or
RS 485 digital signal output

Technical Data
■ Type ■ Output ■ Ambient Conditions
Explosion proof transmitter Warning signal: Temperature:
■ Gases and Ranges Fault signal every 10 sec for 1 second -40 to +167 oF (-40 to +80 oC)
Combustible gases and vapors, Maintenance signal: Pressure: 700 to 1300 mbar
0 to100% LEL 4 mA ±1 mA, 1 Hz modulation Humidity: 0 to 100% r.h., non condensing
Fault signal: 3.2 mA ■ Size
■ Display
■ Relays (optional) 7" H x 5.25" W x 5.25" D

Backlit LCD 2 lines, 20 characters;


resolution 1% LEL menu structure and Two alarm relays, one fault relay, (180 mm x 135 mm x 135 mm)
1-877-PRAXAIR

messages in real text SPDT; user programmable ■ Weight


Rating: 5 lb (2.3 kg)
■ Enclosure 5A 230 VAC, 5A 30 VDC
NEMA 4 & 7, IP 65; ■ Approvals
3/4"NPT female conduit entry ■ Supply Voltage UL, CSA: Class I, Div 1, Group B, C, D
10 to 32 VDC CENELEC EEx d IIC T6;
■ Output
Analog: 4 to 20 mA, 3-wire ■ Power Input T4 -40 to +80 oC, T6 -40 to +40 oC
Digital: HART®, RS 485 Normal operation: 180 mA @24 VDC CE marking: Electromagnetic compatibility
Inrush current: (directive 89/336/EWG)
900 mA for 0.5 msec @24 VDC

Ordering Information
Part Number Description
DRG4543005 Polytron 2 XP Ex with sensor, without relays; UL version
Please refer to
DRG4543000 Polytron 2 XP Ex with sensor and relays; UL version
page F128 for
DRG4543060 Polytron 2 XP Ex with sensor, without relays; CENELEC/CSA version
Gas Detection
DRG4543059 Polytron 2 XP Ex with sensor and relays; CENELEC/CSA version
Controllers
DRG4543052 Polytron 2 XP Infrared Remote Control UL; UL version
DRG4543053 Polytron 2 XP Infrared Remote Control; CENELEC version
Note: Remote sensor kits available upon request
The Draeger® Polytron™ 2 XP Ex measures a wide range of combustible gases and vapors.
Contact your local Praxair representative for specific information on measurement capabilities.

F
124
GAS HANDLING EQUIPMENT
GAS DETECTION SYSTEMS
Toxic Gases and Oxygen Detector Transmitter

Draeger® Polytron™ 2 XP Tox Toxic Gases and Oxygen Detector Transmitter


The Draeger® Polytron™ 2 XP Tox is an explosion proof gas detector for continuous
monitoring of toxic gases and oxygen in ambient air. The transmitter uses state-of-
the-art microprocessor technology to convert the signal from an electrochemical
DrägerSensor® to a 4 to 20 mA analog or a HART® or RS 485 digital signal output.
The unit is designed for one-man calibration, and offers a variety of diagnostics and
self test features. The configuration and calibration of the transmitter is menu guided
and easy to perform, using either the infrared remote control, the built in push buttons
or a HART® hand held terminal. With the optional on board relays, the Draeger®
Polytron™ 2 XP Tox can be operated as a ‘stand alone’ unit.

Features and Benefits

1-877-PRAXAIR
■ DrägerSensor® technology ■ Backlit LCD Display
■ 20 different sensors for up to ■ 4 to 20 mA analog, HART® or RS 485
100 different gases digital signal output
■ Fast, accurate response ■ Multidrop capability
Bigger sensor, longer life Draeger® Polytron™ 2 XP Tox Toxic Gases
■ ■ Optional relays on board
and Oxygen Detector Transmitter
■ Temperature effects compensated ■ UL, CSA, CENELEC approved
between -40 and 149 oF (-40 and 65 oC) ■ CE marking


Technical Data

www.praxair.com/specialtygases
■ Type ■ Output ■ Ambient Conditions
Explosion proof transmitter Warning signal: Temperature:
■ Gases and Ranges Fault signal every 10 sec for 1 sec -40 to +149 oF (-40 to +65 oC)
Toxic gases and Oxygen, ranges user Maintenance signal: Pressure: 700 to 1300 mbar
adjustable (see sensor data sheet) 4mA ±1mA, 1Hz modulation Humidity:
Fault signal: 3.2 mA 0 to 100% r.h. (see sensor data sheet)
■ Display
Backlit LCD 2 lines, 20 characters; ■ Relays (option) ■ Enclosure
resolution varies with the range Two alarm relays, one fault relay SPDT; NEMA 4 & 7, IP 65;
(see sensor data sheet) user programmable 3/4" NPT female conduit entry
Menu structure and messages in real text Rating: 5A 230 VAC, 5A 30 VDC Size: 10.75" H x 5.75" W x 5.25" D
■ Supply Voltage (275 mm x 145 mm x 135 mm)
■ Weight
5.5 lb (2.5 kg) 10 to 32 VDC ■ Approvals
■ Power Input UL, CSA: Class I, Div 1, Group B, C, D
■ Output CENELEC EEx d [ia] IIC T6; T6 -40 to + 65 oC
Analog: 4 to 20 mA, 3-wire Normal operation: 100 mA @ 24 VDC
Inrush current: CE marking: electromagnetic compatibility
Digital: HART®, RS 485 (directive 89/336/EWG)
750 mA for 10 µsec @ 24 VDC

Ordering Information
Part Number Description Please refer to
DRG4543070 Polytron 2 XP Tox without relays (does not include sensor) page F128 for
DRG4543200 Polytron 2 XP Tox with relays (does not include sensor) Gas Detection
DRG4543052 Polytron 2 XP Infrared Remote Control UL, UL version Controllers
DRG4543053 Polytron 2 XP Infrared Remote Control CENELEC version

Ordering Information – Electrochemical DrägerSensors® for Polytron XP Tox Detector Trasmitter


Part Number Description Part Number Description Part Number Description
DRG6809375 Acidic Compounds (AC) L DRG6809685 Hydrogen (H2) DRG6809655 Nitrogen Dioxide (NO2)
DRG6809680 Ammonia (NH3) - LC DRG6809640 Hydrogen Chloride (HCl) DRG6809310 Nitrogen Trifluoride (NF3)
DRG6809645 Ammonia (NH3) - HC DRG6809650 Hydrogen Cyanide (HCN) DRG6809615 Organic Vapors (OV)
DRG6809605 Carbon Monoxide (CO) DRG6809705 Hydrogen Peroxide (H 2O2) - LC DRG6809720 Oxygen (O2)
DRG6809620 Carbon Monoxide (CO) - LS DRG6809070 Hydrogen Peroxide (H 2O2) - HC DRG6809630 Oxygen (O2) - LS
DRG6809665 Chlorine (Cl 2) DRG6809610 Hydrogen Sulfide (H2S) - LC DRG6810290 Ozone (O3)
DRG6810180 Hydrazine (N2H 4) DRG6809710 Hydrogen Sulfide (H2S) - HC DRG6809695 Phosphine (PH3)/Arsine (AsH 3)
DRG6809635 Hydride DRG6809625 Nitric Oxide (NO) - LC DRG6809660 Sulfur Dioxide (SO2)
F
DRG6809980 Hydride SC (Semiconductor) DRG6809715 Nitric Oxide (NO) - HC DRG6809930 Phosgene (COCl2) 125
HC = High Concentration LC = Low Concentration LS = Long-term Stability
GAS HANDLING EQUIPMENT
GAS DETECTION SYSTEMS
Single Point Gas Detection Monitor

Draeger® PointGard® ll Single Point Gas Detection Monitor


The Draeger® PointGard® ll is a microprocessor-based stand-alone gas detector for continu-
ous monitoring of toxic gases and oxygen in ambient air. Gas concentration is displayed using
bright LEDs, while the horn and two strobes provide alarm annunciation where it is needed
most: at the point of the hazard.
The heart of the Draeger® PointGard® ll is the electrochemical DrägerSensor®, the latest
development in gas sensing technology. The DrägerSensor® is designed for accuracy,
stability, and long life. Temperature compensation has been optimized and cross sensitivity
to other gases minimized, ensuring an accurate reading of the target gas concentration.
Installation is easy: just mount the unit on a wall, install the sensor, and plug the line cord into
a 110 or 220 VAC outlet. Sensors are pre-calibrated before shipment, so calibration is not
necessary at start-up. The simple menu guided user interface can be accessed through
3 buttons on the front panel of the instrument.
www.praxair.com/specialtygases

Features and Benefits


■ Economical, stand-alone gas monitor ■ Easy installation and operation
■ DrägerSensor® technology ■ One–man calibration
■ Local alarm annunciation

Draeger® PointGard® ll Single Point


Technical Data Gas Detection Monitor
■ Type ■ Horn
General purpose gas monitor Volume adjustable from 75 to
(not to be used in classified areas) 100 db at one foot
■ Gases and Ranges ■ Relays
Toxic gases (20/50/100 ppm H2S, Two alarm relays, one fault relay;
100/300/500 ppm CO, 300 ppm NH3, normally energized, SPDT.
5 ppm Cl2, 20 ppm SO2, 20 ppm NO2 Rating: 5A 230 VAC,5 A 30 VDC.
10 ppm H2O2, 50 ppm EtO) and User-configurable latching and

O2 (25 volume %) acknowledge ability functions.


1-877-PRAXAIR

■ Display ■ Supply Voltage


3 digit LED display resolution varies 110/220 VAC or 24 VDC
with the range (see sensor data sheet) ■ Ambient Conditions
■ Outputs Temperature:
Analog: 4 to 20 mA +14 to +122 oF (-10 to +50 oC)
Maintenance Signal: 4mA ± 1mA modulation Pressure: 700 to 1300 mbar
or steady 3 mA (user-selectable) Humidity:
Fault signal: 2 mA 5 to 95% r.h. (see sensor data sheet)
■ Alarms ■ Enclosure
2 alarms (A1 and A2). NEMA 4X, IP 65; lockable
User-configurable for 2 rising alarms, ■ Size
2 falling alarms, or 1 rising/1 falling. 12.75" W x 7.25" H x 5.1" D
(324 mm x 184 mm x 130 mm)

Ordering Information
Part Number Description
DRG4543310 PointGard ll (does not include sensor)

Ordering Information – Electrochemical DrägerSensors® for PointGard® II Gas Detectors


Part Number Chemical Part Number Chemical
DRG6809680 Ammonia (NH3) - LC DRG6809705 Hydrogen Peroxide (H2O2) - LC
DRG6809645 Ammonia (NH3) - HC DRG6809610 Hydrogen Sulfide (H2S) - LC
DRG6809605 Carbon Monoxide (CO) DRG6809655 Nitrogen Dioxide (NO2)
DRG6809665 Chlorine (Cl 2) DRG6809630 Oxygen (O2) - LS
DRG6809615 Ethylene Oxide (C2H2O) - EtO DRG6809660 Sulfur Dioxide (SO2)
F LC = Low Concentration LS = Long-term Stability
126 HC = High Concentration
GAS HANDLING EQUIPMENT
GAS DETECTION SYSTEMS
CO2 Gas Analyzer/Transmitter

Draeger® Polytron™ IR CO2 Gas Analyzer/Transmitter


The Draeger® Polytron™ IR CO2 is a gas detector used for continuous monitoring
of carbon dioxide. It offers all benefits of fail-safe IR measurement technology for
applications in rough environments.
The transmitter uses microprocessor technology to convert the signal to a 4 to 20 mA
analog output. The unit is designed for one-man calibration and offers a variety of
diagnostics and self test features.
The configuration and calibration of the transmitter is menu guided and easy to per-
form, using the build in push buttons. According to the explosion protection CENELEC
EEx em [ib] d IIB + H2 T4, Draeger® Polytron™ IR CO2 can be used in hazardous areas.

Features and Benefits Draeger® Polytron™ IR CO2


Minimum maintenance required Linear output signal independent of Gas Analyzer/Transmitter

1-877-PRAXAIR
■ ■

■ Fast and accurate response temperature and humidity


■ No moving parts ■ Adjustable measurement ranges from
2000 ppm up to 30 vol%

Technical Data
■ Type ■ Output ■ Enclosure
Transmitter with infrared Analog: 4 bis 20 mA GRP IP 65/NEMA 4,


sensor technology Maintenance signal: Pg 13.5 cable gland
4 mA ±1 mA, 1 Hz Modulation

www.praxair.com/specialtygases
■ Gases and Range ■ Size
Carbon Dioxide Warning signal: 8" W x 4.7" H x 3.5" D
0 to 1...30 vol %; 3 mA for 1 sec every 10 sec (205 mm x 120 mm x 90 mm)
0 to 2000...9999 ppm Fault signal: < 3.2 mA
■ Weight
■ Long-term Drift ■ Power Supply 4.2 lb (1.9 kg)
< 0.03 vol % 13 to 30 V DC; < 2 W
■ Approvals
(Measuring range 0 to 1 vol %) ■ Ambient Conditions CENELEC EEx em [ib] d IIB + H2 T4
■ Repeatability Temperature: (available upon request) CE marking:
< 0.05 vol % -5 oF to 150 oF (-20 oC to 65 oC) RFI compatibility (directive 89/336/EEC)
(Measuring range 0 to 1 vol %) (-40 oF (-40 oC) available on request)
Humidity:
■ Response Time 0 to 100% r.f., non condensing
T90 < 40 s

Ordering Information Please refer to


Part Number Description page F128 for
DRG8316037 Transmitter IR CO2 with display and sensor Gas Detection
Upon request Non display and CENELEC EEx Controllers
Note: Remote sensor kits available upon request.

F
127
GAS HANDLING EQUIPMENT
GAS DETECTION SYSTEMS
Gas Detection Controllers

Draeger® QuadGard™ Gas Detector Controller


The Draeger® QuadGard™ gas detector controller is a state-of-the-art microprocessor-driven
4-channel gas monitoring system in one wall mount enclosure. The system can be custom-
ized to the specific application requirements. It is fully configurable for all types of transmitters
and gases, using the on-board push buttons. The easy to use menu structure is password
protected. The gas concentration is displayed on a 2 line 20 character LCD display and status
LED’s which allow a quick overview on the condition of the gas monitoring system (power on,
alarm tripped, fault condition recognized).

Features and Benefits


■ Measuring for Tox, Ex or O2
■ Suitable for all 2/3 wire
Draeger® QuadGard™
transmitters and pellistors
Gas Detector Controller
www.praxair.com/specialtygases

■ Fully configurable

Technical Data Ordering Information


■ Control Unit ■ Outputs (system) Part Number Description
Low profile wall mounting enclosure MA 1, MA 2, MA 3 and common DRG4205800 QuadGard IP 54 (CSA)
Local alphanumeric display fault voted, common or single
Front panel membrane push buttons alarm configurations DRG4205810 QuadGard IP 65 (CSA)
Front panel LED’s ■ Input modules DRG4205808 QuadGard NEMA 4 (UL)
Internal alarm 2/3 wire 4-20 mA transmitters DRG4205916 Input module mA (CE)
■ Ingress Protection 3 wire pellistor DRG4205917 Input module SE Ex (CE)
IP 54, IP 65 and NEMA 4 ■ Outputs (per input) DRG4205805 Input module mA (UL), (CSA)
■ Power Supply A 1, A 2, and fault alarm relays
110 V/230 V AC, 50-60 Hz Repeat 4-20 mA DRG4205806 Input module SE Ex (UL)
5 W (100 W maximum) ■ Approvals
24 V DC, 2A EMC EN50081-1 and 50082-2
LVD EN 61010-1

1-877-PRAXAIR

Draeger® Regard-1™ Gas Detector Controller


The Draeger® Regard-1™ is a single point, wall mounting gas detection controller.
The different styles of enclosure allow for mounting either indoors or outdoors.
The control unit is fully configurable to match the parameters of an associated
gas detector.

Features and Benefits


■ Single point control unit ■ Simple operation
■ Suitable for all 2/3 wire transmitters ■ Continuous display
■ Detection of Cl2, Ex, Tox and 02 ■ Password protected
■ Fully configurable
Draeger® Regard-1™
Technical Data Gas Detector Controller
■ Control Unit ■ Input
Low profile wall mounting enclosure 2/3 wire 4-20 mA transmitters Ordering Information
Local alphanumeric display Remote reset Part Number Description
Front panel push buttons ■ Outputs
Front panel LED’s DRG4206661 Regard-1 IP43
A1, A2, F/A3 relays
■ Ingress Protection Repeat 4-20 mA DRG4207630 Regard-1 IP65
IP 54, IP 65 and NEMA 4 ■ Approvals
■ Power Supply EMC EN50081-1 and 50082-2
110 V/230 V AC, 50-60Hz LVD EN 61010-1 Please refer to
24 V DC, 2 A
pages F124, F125 and
F F127 for Gas Detection
128 Transmitters
GAS HANDLING EQUIPMENT
GAS DETECTION SYSTEMS
Portable Gas Monitors

Draeger® CMS® Gas Monitor


Accurate gas measurements are made The CMS does not require gas calibration.
easier with the Draeger® CMS®. This new All measurement and calibration information
generation of spot-check detection is lit- is stored on a bar code on the CMS Chip.
erally as easy as 1-2-3 to operate. Simply An electronics and leak check is performed
insert the CMS Chip and follow the instruc- before each measurement so you are as-
tions on the display as to when to move the sured of accurate indications every time.
slide switch. TWA levels are typically ana- Operating on 4 “AA” cells, the CMS will de-
lyzed in 1-2 minutes. Upon completion of liver about 200 measurements per battery
this process, the concentration is indicated change. An optional remote sampling sys-
on the LCD display. Every chip uses the tem makes the CMS an ideal choice for
exact same procedure so training is confined space entry applications.
minimal.
The on-board data-recorder stores up to
The system is based on Draeger’s 60+ 50 measurements with the gas/concentra-

1-877-PRAXAIR
years of dry chemical reaction technology tion and date/time. The recorder can be set
used in DrägerTubes®. However, the CMS up to record manually or automatically, and
includes mass flow controllers to take a previous measurements can be called up
precise air sample and the color change is on demand.
Draeger® CMS®
measured with a photo-electric eye elimi-
The CMS is currently used extensively in the Gas Monitor
nating any human interpretation or objec-
petrochemical, transportation, and utilities
tivity. Accuracies of +/- 4 to 10% of mea-
industries as well as the fire service and
sured values are achieved for most gases
government regulatory agencies. Popular


and vapors.
applications include TWA screening, confin-

www.praxair.com/specialtygases
ed space entry and emergency response.

Specifications Ordering Information Optional Equipment


■ Size Part Number Description Part Number Description
3.6 x 8.0 x 1.7 in (92 x 205 x 45 mm) DRG6405300 CMS Analyzer DRG6405060 Remote Sample System
■ Weight (does not include chip) DRG8313025 Telescopic Probe
25.6 oz. (730 g) DRG4056455 CMS Indoor Air Quality Kit DRG6405080 Leather Case Carrying,
■ Approvals DRG4055711 CMS Emergency Analyzer
UL: Class I, Division 1, Groups A-D, T4 Response Kit
CSA: Class I, Division 1, Groups A-D, T4 DRG4594631 Nylon Transport Case
MSHA: Permissible Gas Detector Note: Order CMS Chip from list below. DRG9092086 Tube/CMS Handbook
CENELEC: EEx ib IIC T4

Ordering Information – CMS Chip for Draeger


Part Number Chemical Range Part Number Chemical Range Part Number Chemical Range
DRG6406330 Acetic Acid 2.0 - 50.0 ppm DRG6406140 Hydrochloric Acid 20.0 - 500 ppm DRG6406200 Petroleum 20.0 - 500 ppm
DRG6406470 Acetone 40.0 - 600 ppm DRG6406100 Hydrocyanic Acid 2.0 - 50.0 ppm Hydrocarbons
DRG6406550 Ammonia 0.20 - 5.0 ppm DRG6406440 Hydrogen Peroxide 0.20 - 2.0 ppm DRG6406270 Petroleum 100 - 3,000 ppm
DRG6406130 Ammonia 2.0 - 50.0 ppm DRG6406520 Hydrogen Sulfide 0.20 - 5.0 ppm Hydrocarbons
DRG6406020 Ammonia 10.0 - 150 ppm DRG6406050 Hydrogen Sulfide 2.0 - 50.0 ppm DRG6406340 Phosgene 0.05 - 2.0 ppm
DRG6406570 Ammonia 100 - 2,000 ppm DRG6406150 Hydrogen Sulfide 20.0 - 500 ppm DRG6406400 Phosphine 0.10 - 2.50 ppm
DRG6406030 Benzene 0.20 - 10.0 ppm DRG6406220 Hydrogen Sulfide 100 - 2,500 ppm DRG6406410 Phosphine 1.0 - 25.0 ppm
DRG6406160 Benzene 0.50 - 10.0 ppm DRG6406390 Iso-Propanol 40.0 - 1,000 ppm DRG6406420 Phosphine 20.0 - 500 ppm
DRG6406280 Benzene 10.0 - 250 ppm DRG6406360 Mercaptan 0.25 - 6.0 ppm DRG6406500 Phosphine 200 - 5,000 ppm
DRG6406460 Butadiene 1.0 - 25.0 ppm DRG6406380 Methanol 20.0 - 500 ppm DRG6406310 Propane 100 - 2,000 ppm
DRG6406190 Carbon Dioxide 200 - 3,000 ppm DRG6406510 Methylene Chloride 10.0 - 200 ppm DRG6406560 Styrene 2.0 - 40.0 ppm
DRG6406070 Carbon Dioxide 1,000 - 25,000 ppm DRG6406530 Methyl Teriary 10.0 - 200 ppm DRG6406110 Sulfur Dioxide 0.40 - 10.0 ppm
DRG6406210 Carbon Dioxide 1.0 - 20.0 vol% Butyl Ether (MTBE) DRG6406180 Sulfur Dioxide 5.0 - 150 ppm
DRG6406080 Carbon Monoxide 5.0 - 150 ppm DRG6406120 Nitrogen Dioxide 0.50 - 25.0 ppm DRG6406250 Toluene 10.0 - 300 ppm
DRG6406010 Chlorine 0.20 - 10.0 ppm DRG6406060 Nitrous Gases 0.50 - 15.0 ppm DRG6406290 Training Chip Simulation
DRG6406370 Ethanol 100 - 2,500 ppm DRG6406240 Nitrous Gases 10.0 - 200 ppm DRG6406320 Trichloroethylene 5.0 - 100 ppm
DRG6406580 Ethylene Oxide 0.40 - 5.0 ppm DRG6406490 Oxygen 1.0 - 25.0 vol% DRG6406170 Vinyl Chloride 0.30 - 10.0 ppm
DRG6406540 Formaldehyde 0.20 - 5.0 ppm DRG6406430 Ozone 25.0 - 1,000 ppb DRG6406230 Vinyl Chloride 10.0 - 250 ppm F
DRG6406090 Hydrochloric Acid 1.0 - 25.0 ppm DRG6406040 Perchloroethylene 5.0 - 150 ppm DRG6406450 Water Vapor 0.40 - 10.0 mg/L 129
DRG6406260 Xylene 10.0 - 300 ppm
GAS HANDLING EQUIPMENT
GAS DETECTION SYSTEMS
Portable Gas Monitors

DrägerTubes® Gas Detector


The world has counted on DrägerTubes® tubes. Not only do you get the benefit of
more than any other gas and vapor mea- quicker analysis, the larger sample volume
surement device to tell them when the air provides statistically better accuracy. Once
is safe to breathe, to identify an unknown the sample is taken, the larger diameter
hazard, or to check on process gases. For DrägerTubes® and well spaced gradua-
more than 60 years, Draeger has been the tion marks enable distinct and decisive
leader in detector tube technology with measurement readings.
more accurate measurements, a wider
Reagents used in the DrägerTubes® are DrägerTubes®
range of gases and vapors measured, more
chosen to provide not only the most ac- Gas Detector
designs of tubes and more accessories to
curate, but also the most specific results.
meet specific gas and vapor measurement
Use of chemical pre-layers on many tubes
applications.
(like benzene) remove potentially interfering
Though many DrägerTubes® require more gases (e.g. aromatic hydrocarbons) so you
www.praxair.com/specialtygases

than one pump stroke, the sampling time is only measure the targeted chemical, get-
usually faster than the advertised one-stroke ting only the results you want.

accuro® Pump accuro® 2000 Pump Quantimeter™ 1000 Pump


The cornerstone of the DrägerTubes® The measuring ranges of various For routine sampling or extending the mea-
system is the accuro® pump. It draws a DrägerTubes® can be extended to lower suring ranges of various DrägerTubes® in
calibrated 100 ml sample of air through the levels if additional pump strokes are taken. atmospheres requiring an intrinsically safe
DrägerTubes® with each stroke. The one- The accuro® 2000 pump is an electronic pump, the Quantimeter™ is the best choice.
handed operation is simple and allows you pump that can take up to 199 strokes. It provides up to 1,000 strokes using a re-
to reach places that a piston pump can not chargeable battery. Up to 199 strokes can
go. A built-in stroke counter tells you exactly Specifications be programmed into the unit.
how many strokes have been taken. The
visual end-of-stroke indicator definitely ■ Size
Specifications
identifies the conclusion of a pump stroke. 7.4" x 10.6" x 3.9"
(190 x 270 x 100 mm) ■ Size
■ Weight 6.5" x 7.1" x 2.4"

Ordering Information (165 x 180 x 62 mm)


5.3 lb (2.4 kg)
1-877-PRAXAIR

Part Number Description ■ Weight


DRG6400000 accuro® Pump 4.0 lb (1.8 kg)
Ordering Information
DRG4053473 Soft-Sided accuro Pump Kit
Part Number Description
DRG4056443 Hard-Sided accuro Pump Kit Ordering Information
DRG4500200 accuro® 2000 Pump Kit*
DRG6400077 Extension Hose, 3 m Part Number Description
DRG6400000 accuro® Pump
DRG6400078 Extension Hose, 10 m DRG4500231 Quantimeter™ 1000
* accuro pump required (sold separately)
DRG6400079 Extension Hose, 15 m DRG6806430 Universal Charger
DRGCH00214 Motor Vehicle Exhaust Probe
DRGCH00213 Hot Air Probe
DRG6400010 Deluxe Tube Opener

Ordering Information – DrägerTubes®


Part Number Description Part Number Description Part Number Description
DRG6722101 Acetic Acid 5/a 5-80 ppm DRGCH29501 Hydrochloric Acid 1/a 0.5-25 ppm DRG6733181 Ozone 0.05/b 0.05-1.4 ppm
DRGCH22901 Acetone 100/b 100-12,000 ppm DRG6728181 Hydrochloric Acid 50/a 50-5,000 ppm DRG8101501 Perchloroethylene 2/a 2-300 ppm
DRG6728591 Acrylonitrile 0.5/a 0.5-20 ppm DRGCH25701 Hydrocyanic Acid 2/a 2-150 ppm DRG8101691 Petroleum Hydrocarbons 10/a 10-300 ppm
DRG8101631 Alcohol 25/a Range differs by type of alcohol DRG8103251 Hydrogen Fluoride 0.5/b 0.5-90 ppm DRG6730201 Petroleum Hydrocarbons 100/a 10-2,500 ppm
DRG8101711 Ammonia 0.25/a 0.25-3 ppm DRG8101041 Hydrogen Peroxide 0.1/a 0.1-3 ppm DRGCH31101 Phosphine 0.1/a 0.1-40 ppm
DRG6733231 Ammonia 2/a 2-30 ppm DRG8101991 Hydrogen Sulfide 0.2/b 0.2-6 ppm DRGCH28401 Polytest Qualitative Screening Tube +B24
DRGCH20501 Ammonia 5/a 5-700 ppm DRG6728041 Hydrogen Sulfide 0.5/a 0.5-75 ppm DRG6728491 Sulfur Dioxide 0.5/a 0.5-25 ppm
DRG8101841 Benzene 0.5/c 0.5-10 ppm DRG8101831 Hydrogen Sulfide 1/d 1-200 ppm DRGCH31701 Sulfur Dioxide 1/a 1-25 ppm
DRGCH23501 Carbon Dioxide 0.1%/a 0.1-6 VOL % DRGCH29101 Hydrogen Sulfide 100/a 100-2,000 ppm DRG6728781 Sulfuric Acid 1/a 1-5 mg/m3
DRG8101811 Carbon Dioxide 100/a 100-3,000 ppm DRGCH29801 Hydrogen Sulfide 5/b 5-600 ppm DRG8101661 Toluene 5/b 50-300 ppm/5-80 ppm
DRGCH20601 Carbon Monoxide 10/b 10-3,000 ppm DRG6728981 Mercaptan .5/a 0.5-5 ppm DRG6728541 Trichlorethylene 2/a 2-200 ppm
DRG6733051 Carbon Monoxide 2/a 2-300 ppm DRG8101671 Methyl Bromide 0.5/a 5-30 ppm/0.5-5 ppm DRG8101721 Vinyl Chloride 0.5/b 0.5-30 ppm
DRGCH25601 Carbon Monoxide 5/c 5-700 ppm DRG6728311 Nitric acid 1/a 1-50 ppm DRG8101781 Water Vapor 1/b 20-40 mg/l /1-15 mg/l
F DRGCH24301 Chlorine 0.2/a 0.2-30 ppm DRGCH30001 Nitrogen Dioxide 0.5/c 0.5-25 ppm DRG6733161 Xylene 10/a 10-400 ppm
130 DRG6733081 Formaldehyde 0.2/a 0.2-5 ppm DRGCH29401 Nitrous Fumes 0.5/a 0.5-10 ppm

Other tubes are available upon request. Please contact your local Praxair representative.
GAS HANDLING EQUIPMENT
GAS DETECTION SYSTEMS
Portable Gas Monitors

Draeger® Pac III™ Monitor


The Draeger® Pac III™ Monitor delivers the most of any single gas monitor Draeger® Pac III™
available. Very comfortable and easy to be worn on ones belt, lapel, or breast Monitor
pocket all day. The robust polymer housing withstands the use and abuse
expected in demanding industrial applications. A loud audible alarm and bright
visual alarm alert the user of hazardous levels of gas. Two levels of alarm in-
dicate increasing concentrations. The exact concentration of gas is displayed
on the LCD readout. This instrument is operated with only two buttons making
it extremely simple and easy to use.
Applications for the Draeger® Pac III™ monitor include the protection of
workers and contractors at chemical plants, steel mills, and mines.

1-877-PRAXAIR
Specifications
■ Sensors Accepted ■ Size ■ Approvals
See Ordering Information below 2.6" W x 4.3" H x 1.3 D" (67 x 116 x 32 mm) UL: Class I, Division 1, Groups A-D, T6
■ Weight CSA: Class I, Division 1, Groups A-D, T6
7.0 oz. (200 g) MSHA: Permissible Gas Detector


CENELEC: EEx ia IIC T4/T6

www.praxair.com/specialtygases
Ordering Information Optional Equipment
Part Number Description Part Number Description Part Number Description
DRG4530010 Pac III Standard DRG4530337 Pac III Basic CO DRG4530286 Leather Carrying Case
DRG4530011 Pac III Hygiene DRG4530338 Pac III Basic H2S DRG4594631 Nylon Transport Case
DRG4530311 Pac III Hygiene Kit DRG4530339 Pac III Basic O2
The Draeger® Pac III™ Standard and Hygiene will The Draeger® Pac III™ Basic will only accept the
accept any of the different DrägerSensors® listed three sensor types listed. Versions listed above
below. Versions listed above come standard with come standard with a 9-Volt alkaline battery pack
a 9-Volt alkaline battery pack. Sensors must be and PS-2 DraegerSensors® noted.
ordered separately.

Ordering Information – DrägerSensors® XS for Draeger® Pac III™ Monitors


Description Measuring Installed Description Measuring Installed
Range Part Number Range Part Number
Amines 0 - 100 ppm DRG4595422 Hydrogen Peroxide (H 2O2) 0 - 20.0 ppm DRG4595415
Ammonia (NH3) 0 - 200 ppm DRG4595407 Hydrogen Sulfide (H2S) 0 - 100 ppm DRG4595434
Carbon Dioxide (CO 2) 0 - 5.0 %Vol. DRG4595414 Hydrogen Sulfide (H2S) – HC 0 - 1,000 ppm DRG4595403
Carbon Monoxide (CO) 0 - 2,000 ppm DRG4595433 Nitric Oxide (NO) 0 - 100 ppm DRG4595404
Carbon Monoxide (CO) – HC 0 - 10,000 ppm DRG4595431 Nitrogen Dioxide (NO2) 0 - 50.0 ppm DRG4595405
Chlorine (Cl 2) 0 - 20.0 ppm DRG4595409 Odorant (Mercaptan) 0 - 40.0 ppm DRG4595424
Hydrazine (N2H 2) 0 - 3.00 ppm DRG4595439 Organic Vapors (OV) 0 - 200 ppm DRG4595410
Hydrides (Phosphine, etc.) 0 - 20.0 ppm DRG4595412 Organic Vapors-A 0 - 200 ppm DRG4595411
Hydrogen (H 2) 0 - 2,000 ppm DRG4595423 Oxygen (O2) 0 - 25.0 %Vol. DRG4595435
Hydrogen Cyanide (HCN) 0 - 50.0 ppm DRG4595408 Phosphine (PH3) – HC 0 - 1,000 ppm DRG4595413
Hydrogen Fluoride (HF) 0 - 30.0 ppm DRG4595430 Sulfur Dioxide (SO2) 0 - 100 ppm DRG4595406
Hydrogen Chloride (HCl) 0 - 30.0 ppm DRG4595430
HC = High Concentration

F
131
GAS HANDLING EQUIPMENT
GAS DETECTION SYSTEMS
Portable Gas Monitors

Draeger® MiniWarn™ Monitor


The Draeger® MiniWarn™ Monitor is a multi- easy to take into a confined space or wear
ple gas-measuring device that is well suited on one’s body all day. The rugged polymer
to a wide variety of industrial gas detection housing is lighter than metal and resists
applications. The flexibility of the Draeger® dirt and liquids as well as many corrosive
MiniWarn ™ product line allows every user to chemicals that one may encounter in an
optimally configure an instrument to meet industrial environment. All joints and open-
their needs. Choose from over 25 different ings are sealed or have gaskets to prevent Draeger® MiniWarn™
plug-and-play DrägerSensors®, 3 inter- the ingress of dirt or water. Monitor
changeable battery packs, and a wide var-
The 360o visual red alarm light and loud
iety of options and accessories to meet
audible alarm provide an attention getting
your exact gas monitoring requirements.
warning that gas concentrations have re-
The most important feature of the Draeger® ached hazardous levels. The large easy-to-
MiniWarn ™ monitor is the ease-of-operation. read display quickly indicates the gases,
www.praxair.com/specialtygases

The three buttons on the front of the unit their concentrations, and other relevant
turn it ON and OFF, acknowledge alarms, data to the user.
and access frequently required features
Confined space entry is the most popular
such as battery levels and fresh-air calibra-
application for the Draeger® MiniWarn ™
tion. All other functions and features are
monitor such as those occurring in the
accessed through plain text password-
utilities, petrochemical plants, and under-
protected menus.
ground mines. Such applications are espe-
The small profile of the Draeger® MiniWarn ™ cially convenient with Draeger® MiniWarn™
monitor (even when equipped with its ex- monitor’s easily attached and compact
ternal 30 ft draw sample pump) makes it motorized remote sample draw pump.

Specifications
■ Sensors Accepted ■ Size ■ Approvals
See Ordering Information below 3.1" W x 5.6" H x 2.3" D (78 x 143 x 58 mm) UL: Class I, Division 1, Groups A-D, T4
■ Weight CSA: Class I, Division 1, Groups A-D, T4

15.8 oz. (450 g) MSHA: Permissible Gas Detector


CENELEC: EEx ia d IIC T4
1-877-PRAXAIR

Ordering Information Optional Equipment


Part Number Description Part Number Description
DRG4552693 Draeger® MiniWarn™ Ex/O2 DRG6408112 Remote Sample Pump
DRG4552692 Draeger® MiniWarn™ Ex/O 2/H2S DRG6408134 Leather Carrying Case
DRG4552691 Draeger® MiniWarn™ Ex/O2/CO DRG4552746 Nylon Carrying Case
DRG4552690 Draeger® MiniWarn™ Ex/O2/CO/H2S DRG4523069 Pelican Carrying Case
Note: The Draeger® MiniWarn™ Kits listed above include the MiniWarn monitor with NiCd DRG6408116 Alkaline Battery Pack
battery pack, noted sensors, single-unit battery charger system, calibration adapter, and
instruction manuals. For other sensor selections refer to the table below.

Ordering Information – DrägerSensors® XS for MiniWarn™ Monitors


Description Measuring Installed Description Measuring Installed
Range Part Number Range Part Number
Amines 0 - 100 ppm DRG4595422 Hydrogen Sulfide (H2S) – HC 0 - 1,000 ppm DRG4595403
Ammonia (NH3) 0 - 200 ppm DRG4595407 Nitric Oxide (NO) 0 - 100 ppm DRG4595404
Carbon Dioxide (CO 2) 0 - 5.0 %Vol. DRG4595414 Nitrogen Dioxide (NO2) 0 - 50.0 ppm DRG4595405
Carbon Monoxide (CO) 0 - 2,000 ppm DRG4595433 Odorant (Mercaptan) 0 - 40.0 ppm DRG4595424
Carbon Monoxide (CO) – HC 0 - 10,000 ppm DRG4595431 Organic Vapors (OV) 0 - 200 ppm DRG4595410
Chlorine (Cl 2) 0 - 20.0 ppm DRG4595409 Organic Vapors-A 0 - 200 ppm DRG4595411
Hydrides (Phosphine, etc.) 0 - 20.0 ppm DRG4595412 Oxygen (O2) 0 - 25.0 %Vol. DRG4595435
Hydrogen (H 2) 0 - 2,000 ppm DRG4595423 Phosphine (PH3) – HC 0 - 1,000 ppm DRG4595413

F Hydrogen Cyanide (HCN) 0 - 50.0 ppm DRG4595408 Sulfur Dioxide (SO2) 0 - 100 ppm DRG4595406

132 Hydrogen Sulfide (H2S) 0 - 100 ppm DRG4595434


HC = High Concentration
GAS HANDLING EQUIPMENT
GAS DETECTION SYSTEMS
Portable Gas Monitors

Draeger® MultiWarn II™ Monitor


The Draeger® MultiWarn™ II Monitor The strong enclosure with stands the
combines electrochemical, catalytic oxi- toughest industrial environments, including
dation and infrared (IR) sensing technology the elements like rain and extreme tempera-
for a total of up to 5 sensors. You are able tures. A loud audible and bright visual alarm
to choose between over 25 different sends a strong warning to the user that
DrägerSensors®, 2 different catalytic sen- hazardous levels of gas are present.
sors and 2 different IR sensors. It is the
Another strength is the optional IR Sensor.
smallest gas monitor that is able to utilize
The infrared combustible gas (IR-Ex) sensor Draeger® MultiWarn™ II Monitor
all of these technologies in one package.
measures a wide range of hydrocarbons.
The multiple gas measurement and internal
However, unlike catalytic sensors, the IR
pump make this unit an ideal choice for and propane can be measured from ppm
sensor will measure hydrocarbons in inert
confined space entry applications like those to 100 % LEL to 100 %Vol. which makes it
backgrounds (without oxygen). It can also
found in chemical plants, utility passage well suited to the gas industry.
measure heavier hydrocarbons (like turpen-

1-877-PRAXAIR
ways, and paper mills.
tine, kerosene and jet fuels) from ppm to The IR-CO2 sensor makes the Draeger®
The Draeger® MultiWarn II monitor includes % LEL levels. Poisoning gases like H2S, MultiWarn II monitor the right choice for bre-
many “strengths”. The strong internal pump halogenated hydrocarbons and silicones weries, carbonated beverage bottlers, and
can draw gases from over 100 ft (30 m). have no affect on the IR-Ex Sensor, making bulk gas handlers who need to measure
This is useful for deep ship holds, large it ideal for industries that make or use these Carbon Dioxide. Detection capabilities are
storage silos or reaction towers in a refinery. types of compounds. Gases like methane from low ppm levels to 25 %Vol. of CO2 .

Specifications


■ Sensors Accepted ■ Size ■ Approvals

www.praxair.com/specialtygases
See Ordering Information below 2.2" H x 4.3" W x 2.6" D (55 x 110 x 65 mm) MSHA: Permissible Gas Detector
■ Infrared Sensors Installed ■ Weight CENELEC: EEx ia d s IIC T4
Combustible Gases (Ex) or 2.2 lb (1.0 kg) (without IR Sensor)
Carbon Dioxide (CO2) CENELEC: EEx ia d s IIB + H2 T4
■ Approvals (with IR Sensor)
UL: Class I, Division 1, Groups A-D, T4
CSA: Class I, Division 1, Groups A-D, T4

Ordering Information Optional Equipment


Part Number Description Part Number Description Part Number Description
DRG4523040 Draeger® MultiWarn™ II Ex/O2 DRG4523004 Draeger® MultiWarn™ II IR-CO 2 DRG6408134 Leather Carrying Case
DRG4523041 Draeger® MultiWarn™ II Ex/ DRG4523054 Draeger® MultiWarn™ IR-CO2/O2 DRG4594631 Nylon Transport Case
O2/CO DRG4523003 Draeger® MultiWarn™ II IR-Ex DRG4523069 Pelican Transport Case
DRG4523042 Draeger® MultiWarn™ II Ex/ DRG4523048 Draeger® MultiWarn™ II IR-Ex/O 2
O2/H2S
DRG4523049 Draeger® MultiWarn™ II IR-Ex/
DRG4523043 Draeger® MultiWarn™ II Ex/ O2/CO/H2S
O2/CO/H2S
Kits include the Draeger ® MultiWarn™ monitor with NiCd battery pack, noted sensors, single-unit battery charger
system, calibration adapter, and instruction manuals. For other sensor selections, see below.

Ordering Information – DrägerSensors® XS for Draeger® MiniWarn ™ Monitors


Description Measuring Installed Description Measuring Installed
Range Part Number Range Part Number
Amines 0 - 100 ppm DRG4595422 Hydrogen Sulfide (H2S) – HC 0 - 1,000 ppm DRG4595403
Ammonia (NH3) 0 - 200 ppm DRG4595407 Nitric Oxide (NO) 0 - 100 ppm DRG4595404
Carbon Dioxide (CO 2) 0 - 5.0 %Vol. DRG4595414 Nitrogen Dioxide (NO2) 0 - 50.0 ppm DRG4595405
Carbon Monoxide (CO) 0 - 2,000 ppm DRG4595433 Odorant (Mercaptan) 0 - 40.0 ppm DRG4595424
Carbon Monoxide (CO) – HC 0 - 10,000 ppm DRG4595431 Organic Vapors (OV) 0 - 200 ppm DRG4595410
Chlorine (Cl 2) 0 - 20.0 ppm DRG4595409 Organic Vapors-A 0 - 200 ppm DRG4595411
Hydrides (Phosphine, etc.) 0 - 20.0 ppm DRG4595412 Oxygen (O2) 0 - 25.0 %Vol. DRG4595435
Hydrogen (H 2) 0 - 2,000 ppm DRG4595423 Phosphine (PH3) – HC 0 - 1,000 ppm DRG4595413
Hydrogen Cyanide (HCN) 0 - 50.0 ppm DRG4595408 Sulfur Dioxide (SO2) 0 - 100 ppm DRG4595406
F
Hydrogen Sulfide (H22) 0 - 100 ppm DRG4595434
133
HC = High Concentration
GAS HANDLING EQUIPMENT
SAFETY APPARATUS
Cylinder Handling

Cylinder Wall Bracket


All steel construction cylinder support products share many quality construction features.
Heavy 11 gauge steel construction. All surfaces coming in contact with cylinders are
protected with edge guarding to help maintain your cylinders. Steel parts powder painted. FIRG-100
All support straps are 1.5 inch (3.8 cm) wide with cinch buckle. Supports cylinders from
4.0 to 12.0 inch (10 to 30 cm) diameter.
Part Description Dimensions Weight
Number (W x D x H) lb/kg
FIRG-100 Single Cylinder Wall Bracket 8" x 2.25" x 4.25" (20 x 6 x 11 cm) 3/1.4
FIRG-200 Dual Cylinder Wall Bracket 24" x 2.25" x 4.25" (61 x 6 x 11 cm) 8/3.6
FIRG-300 Triple Cylinder Wall Bracket 36" x 2.25" x 4.25" (91 x 6 x 11 cm) 11/5.0 FIRG-200

Single Cylinder Adjustable Bracket


www.praxair.com/specialtygases

Molded from reinforced polypropylene, this bracket can be adjusted to cradle any cylinder
from 4 to 14 inch (10 to 36 cm) diameter. Unit is set to designated cylinder diameter.
Recessed set screws lock in width position, mounts to wall. Includes both strap and
security chain sets.
FIRG-110
Part Description Dimensions Weight
Number (W x D x H) lb/kg
FIRG-110 Single Cylinder Adjustable Bracket 9" x 4" x 5" (23 x 10 x 13 cm) 3.0/1.4

Cylinder Bench Mount Bracket


This bench mount single cylinder bracket uses dual 3/8 inch diameter mounting
posts to clamp to bench or table tops from 3/8 inch to 1-3/4 inch thick. FIRG-150
Standard strap to secure cylinder.
Part Description Dimensions Weight
Number (W x D x H) lb/kg

FIRG-150 Single Cylinder Bench Mount Bracket 8" x 4.25" x 4.25" (20 x 11 x 11 cm) 3.0/1.4
1-877-PRAXAIR

FIRG-250 Dual Cylinder Bench Mount Bracket 24" x 4.25" x 4.25" (61 x 11 x 11 cm) 26/11.8

Single Cylinder Floor Stand


Safely supports cylinders 4 to 10 inch (10 to 25 cm) diameter. Uses adjustable compression
bar and standard cylinder straps for excellent security. Floor mounting holes included.
Part Description Dimensions Weight
Number (W x D x H) lb/kg FIRG-181
FIRG-181 Single Cylinder Floor Stand 16" x 16" x 15" (41 x 41 x 38 cm) 21/9.5

SNAP CAP
Designed to fit most North American high and low pressure gas cylinders, the SNAP CAP
cylinder safety device meets DOT standards. The SNAP CAP denies access to the main
cylinder control and regulator attachment, rendering the cylinder, it’s contents, and your
regulator useless to anyone but your designated personnel. At less than the cost of a cylinder
refill and much less than a regulator, the value is obvious. Welded steel construction and
powder coated provides many years of use.
Part Number Size/Description Weight lb/kg
FIRG-2501 6.5" x 3-1/8" x 11UN, High Pressure Fine Thread 4.0/1.8
FIRG-2502 6.5" x 3-1/2" x 11UN, Low Pressure Fine Thread 4.0/1.8
FIRG-2503 6.5" x 3-1/8" x 11UN, High Pressure Course Thread 4.0/1.8
FIRG-2504 6.5" x 3-1/2" x 11UN, Low Pressure Course Thread 4.0/1.8
F Note: Padlock Included
134
GAS HANDLING EQUIPMENT
SAFETY APPARATUS
Cylinder Handling

Cylinder Wall/Floor Stand


Support for storage from two to four cylinders up to 12 inch (30 cm) diameter each.
Straps secure cylinders. Epoxy powder paint finish. Mounts to wall or floors. FIRG-275

Part Description Dimensions Weight


Number (W x D x H) lb/kg
FIRG-275 Two Cylinder Wall/Floor Stand 28" x 10" x 30" (71 x 25 x 76 cm) 41/19
FIRG-375 Three Cylinder Wall/Floor Stand 40" x 10" x 30" (102 x 25 x 76 cm) 56/26
FIRG-475 Four Cylinder Wall/Floor Stand 52.5" x 10" x 30" (133 x 25 x 76 cm) 66/30

Cylinder Process Station


Similar in features to the cylinder wall/floor stands, these units add an elevated panel to

1-877-PRAXAIR
attach regulators and control panels. Shipped partially assembled (FIRG-277 and FIRG-377)
for freight savings.
FIRG-277
Part Description Dimensions Weight
Number (W x D x H) lb/kg
FIRG-277 Two Cylinder Process Station 28" x 12" x 72" (71 x 30 x 183 cm) 61/28
FIRG-377 Three Cylinder Process Station 40" x 12" x 72" (102 x 30 x 183 cm) 78/36
FIRG-477 Four Cylinder Process Station 51.75" x 14" x 72" (131 x 36 x 183 cm) 160/73


www.praxair.com/specialtygases
Cylinder Floor Stand
Designed and built for the safe storage of industrial and commercial use gas cylinders up
to 12 inches diameter, these stationary racks and process stations are constructed from
11 gauge and heavier plate steel. Four-, six- and eight-cylinder capacity racks share the FIRG-600
1.5 inch polypropylene straps and steel cinch buckles used in our brackets. Fully welded
construction and quality epoxy powder paint finishes provide structural integrity and long
service life. As with our cylinder brackets, surfaces coming into direct contact with the
cylinders are protected with steel reinforced vinyl edge guards, protecting your equipment.
Part Description Dimensions Weight
Number (W x D x H) lb/kg
FIRG-400 Four Cylinder Floor Stand 36.5" x 24" x 30" (93 x 61 x 76 cm) 69/31
FIRG-600 Six Cylinder Floor Stand 48.5" x 24" x 30" (123 x 61 x 76 cm) 81/37
FIRG-800 Eight Cylinder Floor Stand 64" x 24" x 30" (163 x 61 x 76 cm) 93/42

Cylinder Process Station


Similiar in features to the cylinder floor stands, these units add an elevated panel to attach
regulators and control panels.
Part Description Dimensions Weight
FIRG-400P
Number (W x D x H) lb/kg
FIRG-400P Four Cylinder Process Station 36.5" x 24" x 72" (93 x 61 x 76 cm) 98/45
FIRG-600P Six Cylinder Process Station 48.5" x 24" x 72" (123 x 61 x76 cm) 119/54
FIRG-800P Eight Cylinder Process Station 64" x 24" x 72" (163 x 61 x 76 cm) 141/64

F
135
GAS HANDLING EQUIPMENT
SAFETY APPARATUS
Cylinder Handling

Tube Style Cylinder Racks


Tube style racks are recommended where cylinders may be exposed to vehicular traffic or
material handling equipment collisions. These racks fully surround cylinders with 2 inch square
steel heavy gauge (.125" wall) tubes welded and sealed with epoxy powder paint. Two levels
of welded steel chains with snaps on each end make cylinder racking easy and convenient.
All feature fully welded arms and backs, and quickly bolt together, saving half the freight cost
over fully assembled units. We will ship units fully assembled on request. All racks are
available in standard and custom configurations from one to 16 or more cylinder capacity.
Process station versions available. All listed units meet or exceed requirements for UFC,
NFPA, CGA, and OSHA, as well as Seismic Zone 4 requirements.
FIRG-STD-1X2 FIRG-STD-2X2
Part Number Description Dimensions (W x D x H) Weight (lb/kg)
FIRG-STD-1X1 1 Cylinder Tube Rack, 1 cyl wide x 1 deep 16" x 16" x 30" (41 x 41 x 76 cm) 90/41
FIRG-STD-1x2 2 Cylinder Tube Rack, 1 cyl wide x 2 deep 16" x 26" x 30" (41 x 66 x 76 cm) 105/48
FIRG-STD-1x3 3 Cylinder Tube Rack, 1 cyl wide x 3 deep 16" x 38" x 30" (41 x 97 x 76 cm) 120/55
www.praxair.com/specialtygases

FIRG-STD-1x4 4 Cylinder Tube Rack, 1 cyl wide x 4 deep 16" x 50" x 30" (41 x 127 x 76 cm) 135/61
FIRG-STD-2x1 2 Cylinder Tube Rack, 2 cyl wide x 1 deep 30" x 16" x 30" (76 x 41 x 76 cm) 132/60
FIRG-STD-2x2 4 Cylinder Tube Rack, 2 cyl wide x 2 deep 30" x 28" x 30" (76 x 71 x 76 cm) 150/68
FIRG-STD-2x3 6 Cylinder Tube Rack, 2 cyl wide x 3 deep 30" x 38" x 30" (76 x 97 x 76 cm) 168/76
FIRG-STD-2X4 8 Cylinder Tube Rack, 2 cyl wide x 4 deep 30" x 50" x 30" (76 x 127 x 76 cm) 186/85
FIRG-STD-3x1 3 Cylinder Tube Rack, 3 cyl wide x 1 deep 42" x 16" x 30" (107 x 41 x 76 cm) 167/76
FIRG-STD-3x2 6 Cylinder Tube Rack, 3 cyl wide x 2 deep 42" x 28" x 30" (107 x 71 x 76 cm) 214/97
FIRG-STD-3x3 9 Cylinder Tube Rack, 3 cyl wide x 3 deep 42" x 40" x 30" (107 x 102 x 76 cm) 261/119
FIRG-STD-3x4 12 Cylinder Tube Rack, 3 cyl wide x 4 deep 42" x 52" x 30" (107 x 132 x 76 cm) 308/140
FIRG-STD-4x1 4 Cylinder Tube Rack, 4 cyl wide x 1 deep 58" x 16" x 30" (147 x 41 x 76 cm) 194/88 The G-STD Series racks come standard
FIRG-STD-4x2 8 Cylinder Tube Rack, 4 cyl wide x 2 deep 58" x 28" x 30" (147 x 71 x 76 cm) 249/113 with bolt-on rear panels offering great
FIRG-STD-4x3 12 Cylinder Tube Rack, 4 cyl wide x 3 deep 58" x 40" x 30" (147 x 102 x 76 cm) 294/134 freight savings and superior flexibility.
FIRG-STD-4x4 16 Cylinder Tube Rack, 4 cyl wide x 4 deep 58" x 52" x 30" (147 x 132 x 76 cm) 339/154 We will fully assemble units on request.

Four Wheel One Cylinder Hand Truck


Industrial quality hand trucks for gas cylinders up to 12 inch (30 cm) diameter. These durable
units are configured for one cylinder with 8 inch semi-pneumatic wheels (model G-903) or

10.5 inch fully pneumatic (model G-909) for safe, convenient transport of medical, industrial,
and commercial use gases. Construction is of heavy 11 and 10 gauge HR Steel with 3/16
1-877-PRAXAIR

inch thick steel supports and 1.0 inch diameter x 14 gauge round steel tube with heavy poly FIRG-904
straps with steel cinch buckles. Swing-down steel carriages allow use of rear swivel casters
for additional safety and control. Units are epoxy powder coated for durability.
Part Description Dimensions Weight
Number (W x D x H) lb/kg
FIRG-903 Four wheel one cylinder hand truck – 19"x 19" x 47" (48 x 48 x 119 cm) 44/20
semi-pneumatic wheels
FIRG-904 Four wheel one cylinder hand truck – 19"x 21"x 47" (48 x 50 x 119 cm) 44/20
fully pneumatic wheels

Four Wheel Two Cylinder Hand Truck


Designed to safely transport two cylinders up to 12 inch (30 cm) diameter.
FIRG-953
Two swivel casters fold down into place when needed. Gray powder paint for years
of service. 10.5 inch (27 cm) fully pneumatic main wheels and 3 inch (7.5 cm) swivel
casters give excellent all surface control
Part Description Dimensions Weight
Number (W x D x H) lb/kg
FIRG-953 Four Wheel Two Cylinder Hand Truck 29" x 18" x 47" (74 x 46 x 119 cm) 55/25

Cylinder Wheeled Cart


Will transport from four to six cylinders up to 10 inches (25 cm) in diameter. Two levels of
strap support, four swivel casters (two locking) for interior floor transport. Ships partially FIRG-430
assembled for freight savings.
Part Description Dimensions Weight
F Number (W x D x H) lb/kg
136 FIRG-430 Four Cylinder Wheeled Cart 40" x 24" x 72" (102 x 61 x 183 cm) 130/59
FIRG-630 Six Cylinder Wheeled Cart 52" x 24" x 72" (132 x 61 x 183 cm) 140/64
GAS HANDLING EQUIPMENT
TECHNICAL DATA
Materials Compatibility

Gas Compatibility Key to Materials Compatibility


The compatibility data* shown on the following pages has S – Satisfactory for use with the intended gas.
been completed by Praxair to assist in evaluating the appro- U – Unsatisfactory for use with the intended gas.
priate materials to use in handling various gases. It is ex-
C1 thru C7 –
tremely important that all gas control equipment be compat- Conditionally acceptable for use with the intended gas as follows:
ible with the gas being passed through it. The use of a device
C1 – Satisfactory with brass having a low (65-70% maximum)
that is not compatible with the gas being used may damage
copper content. Brass with higher copper content is
the unit and cause a leak that could result in property dam-
age or personal injury. To reduce potentially dangerous unacceptable.
situations, always check for the compatibility of materials C2 – Satisfactory with acetylene; however, cylinder acetylene is
before using any gases in your gas control equipment. packaged dissolved in a solvent (generally acetone) which
may be incompatible with these elastomers.
Since combinations of gases are virtually unlimited, mixtures
C3 – Compatibility varies depending on specific Kalrez®
(except for Praxair’s Oxyfume®, Medifume™ and Carboxide®
compound used. Consult E. I. DuPont for information on
sterilizing gas mixtures) are not listed in the Compatibility

1-877-PRAXAIR
specific applications.
Chart. Before using a gas mixture or any gas not listed in
the chart, we strongly urge you to contact Praxair for C4 – Satisfactory with brass, except where acetylene or acetylides
information. are present.
C5 – Generally unsatisfactory, except where specific use conditions
Directions have proven acceptable.
To use this chart, proceed as follows: C6 – Satisfactory below 1000 psig.
1 Locate the gas you are using in the first column. C7 – Satisfactory below 1000 psig where gas velocities do not
exceed 30 ft /sec.


2 Compare the materials of construction for the equipment you
I– Insufficient data available to determine compatibility with
intend to use with the “Materials of Construction” shown in the

www.praxair.com/specialtygases
the intended gas.
Compatibility Chart. Then use the “Key to Materials Compati-
bility” to determine compatibility. * This chart has been prepared for use with dry (anhydrous) gases at normal
operating temperature of 70 oF (21 oC). Information may vary if different
operating conditions exist. Systems and equipment used in oxidizer gas
service (e.g., Oxygen or Nitrous Oxide) must be cleaned for oxidizer service.

Important
This information is for experienced operators who know the general and it is offered solely as a convenience to its customers. While
principles and the safety precautions to be observed in handling Praxair believes that this information is accurate and factual as of
specialty gases and associated equipment. If you are not certain the date of this publication, this information is intended to be used
you fully understand these safety precautions, we urge you to ob- only as a guide in providing general information with respect to the
tain and read the applicable Material Safety Data Sheet (MSDS) products mentioned; and, therefore, it is not to be taken as a warr-
and Equipment Instruction Booklet. We also urge you to obtain anty or representation for which Praxair assumes legal responsibility.
and read Praxair’s booklets, “Condensed Safety Information, Com- Since the user’s product formulation, specific use application, and
pressed Gases and Cryogenic Liquid” (P-12-237) and “Guidelines conditions of use are all outside Praxair’s control, Praxair makes
for Handling Compressed Gas Cylinders and Cryogenic Liquid no warranty or representation regarding the result which may be
Containers” (P-14-153). These publications are available from obtained by the user. It shall be the responsibility of the user to
your Praxair representative. determine the suitability of the user’s gas control equipment for
use with the products mentioned.
The information contained in the Compatibility Chart has been
compiled by Praxair from what it believes are authoritative sources

F
137
GAS HANDLING EQUIPMENT
TECHNICAL DATA
Materials Compatibility

Materials of Construction

Metals Plastics Elastomers

Stainless Steel

Polycarbonate

Polyurethane
Carbon Steel

Aluminum

Neoprene
Buna-N
Copper

Kalraz
Monel

Teflon

Kynar
Tefzel
Brass

Kel-F

Viton
Zinc

PVC
Common Chemical
Name Formula

Acetylene C2 H2 C1 S S S U U S S S S S I I S C2 C2 C2 C2

Air – S S S S S S S S S S S S S S S S S S

Ammonia NH3 U S S S U U S S S S U S U C3 U S S U
www.praxair.com/specialtygases

Argon Ar S S S S S S S S S S S S S S S S S S

Arsine AsH3 S S S C5 I S S S S S S S I S S S S U

Boron Trichloride BCl3 U S S U I S S S S S S S I C3 I I I I

Boron Trifluoride BF3 S S S C5 I S S S S S S S I C3 I I I I

1,3-Butadiene C4 H6 S S S S S S S S S S S S U S S U S U

Butane C4H10 S S S S S S S S S S S S U S S S S S

1-Butene C4 H8 S S S S S S S S S S S S U S S S S S

Cis-2-Butene C4 H8 S S S S S S S S S S S S U S S S S S

Trans-2-Butene C4 H8 S S S S S S S S S S S S U S S S S S

Carbon Dioxide CO2 S S S S S S S S S S S S S S S S S S


Carbon Monoxide CO S S S S S S S S S S S S S S I S S S
1-877-PRAXAIR

Carboxide ®/ – C4 S S I I U I S S I I U U C3 U U U U
Medifume™

Chlorine Cl2 U S S U U U S S S S S U U S S U U U

Deuterium D2 S S S S S S S S S S S S I S S S S S

Diborane B2H6 S S S S I S S S S S S S I S I I I I

Dichlorosilane H2SiCl2 S S S U I S S S S S S I I S I I I I

Dimethyl Ether C2H6O S S S S S S S S S S S S U S S S S I

Dimethylamine (CH3)2NH U S S U U U S S S I U S I I U U S I

Disilane Si2H6 S S S I I S S S S S S S U I S I S I

Ethane C2 H6 S S S S S S S S S S S S I S S S S S

Ethyl Chloride C2H5Cl S S S U I S S S S S S U U S S S S U

Ethylene C2 H4 S S S S S S S S S S S I I S S S S I

Ethylene Oxide C2H4O C4 S S C5 I U I S S I I U U C3 U U U U

Halocarbon 14 CF4 S S S S I S S S S S S U U C3 S S S S

Halocarbon 22 CHCIF2 S S S C5 I S S S S S S U U C3 U U S U

Halocarbon 23 CHF3 S S S C5 I S S S S S S U U C3 I I I S

Halocarbon 116 C 2 F6 S S S S S S S S S S S U U C3 I I I S

Halocarbon 134A CH2FCF3 S S S C5 I S S I I I I I I I I U U I

Halocarbon 218 C 3 F8 S S S C5 I S S S S S I I I I I I I I
F
Helium He S S S S S S S S S S S S S S S S S S
138
Hydrogen H2 S S S S S S S S S S S S S S S S S S
GAS HANDLING EQUIPMENT
TECHNICAL DATA
Materials Compatibility

Materials of Construction

Metals Plastics Elastomers

Stainless Steel

Polycarbonate

Polyurethane
Carbon Steel

Aluminum

Neoprene
Buna-N
Copper

Kalraz
Monel

Teflon

Kynar
Tefzel
Brass

Kel-F

Viton
Zinc

PVC
Common Chemical
Name Formula

Hydrogen Bromide HBr U S S U U U S S S I S S I I S U U I

Hydrogen Chloride HCl U S S U U U S S S S S S U S S U U U

1-877-PRAXAIR
Hydrogen Fluoride HF U S S U U U S S S I S S I I S U U I

Hydrogen Sulfide H2 S U S S S I I S S S S S S S S U S S S

Isobutane C4H10 S S S S S S S S S S S S U S S S S S

Isobutylene C4 H8 S S S S I S S S S S S S I S S S S I

Krypton Kr S S S S S S S S S S S S S S S S S S

Methane CH4 S S S S S S S S S S S S I S S S S S


Methyl Bromide CH3Br C5 S S U I U U S S I I I I I S U U I

www.praxair.com/specialtygases
Methyl Chloride CH3Cl S S S U U S S S S S S I I S S U U U

Monomethylamine CH3NH2 U S S C5 U U S I S I U I I I S S S I

Natural Gas (Dry) – S S S S S S S S S S S S I S S S S S

Neon Ne S S S S S S S S S S S S S S S S S S

Nitric Oxide NO U S S S I S S S S S I S I S I I S I

Nitrogen N2 S S S S S S S S S S S S S S S S S S

Nitrogen Dioxide NO2 U S S S I U S S S S I U I S U U U U

Nitrogen Trifluoride NF3 C5 C5 S U U C5 S S S I S I I I I I I I

Nitrous Oxide N2 O S S C6 C6 S S S S C5 S S S I C3 S S S S

Oxygen O2 S C7 C7 C7 S S S S C5 S S S S C3 S U U S
®
Oxyfume Mixtures – C4 S S I I U I S S I I U U C3 U U U U

Phosphine PH3 S S S S I I S S S S I I I S I I I I

Phosphorous PF5 I S S I I I S S S I S I I S S S S S
Pentafluoride

Propane C3 H8 S S S S S S S S S S S S U S S S S S

Propylene C3 H6 S S S S S S S S S S S S U S S U U U

Refrigerant Gases – See Halocarbons

Silane SiH4 S S S S I S S S S S S S I S S S S S

Silicon Tetrachloride SiCl4 I S S U I U S S S I I U I C3 I I I I

Silicon Tetrafluoride SiF4 S S S S I S S S S S S S I C3 S S S S

Sulfur Dioxide SO2 U S S C5 U U S S S S S S U S S U U S

Sulfur Hexafluoride SF6 S S S S I S S S S S S S I C3 S S S S

Trichlorosilane HSiCl3 S S S U I I S S S I I U I C3 I I I I

Trimethylamine (CH3)3N U S S U U U S S S S U S I I U U S I
F
Tungsten Hexafluoride WF6 U C5 S U U U S I S S S S I I U U U I
139
Xenon Xe S S S S S S S S S S S S S S S S S S
GAS HANDLING EQUIPMENT
TECHNICAL DATA
Conversion Factors

Density To Obtain
3
g/ml kg/m lb/ft3 lb/in3 lb/U.S. gal

Multiply By

g/ml – 1000 62.428 0.0361273 8.3454


kg/m3 0.001 – 0.062428 3.61273 x 10-5 0.0083454
lb/ft 3 0.0160185 16.018463 – 5.78704 x 10-4 0.13368
lb/in3 27.679905 27,679.9 1728 – 231
lb/U.S. gal 0.1198264 119.8264 7.4805195 0.004329 –

Flow To Obtain
www.praxair.com/specialtygases

3 3 3
cm /min cm /sec ft /hr ft3/min m3/hr m3/min L/hr L/min

Multiply By

cm3/min – 0.0166667 0.0021189 0.0000353 0.00006 0.000001 0.06 0.001


cm3/sec 60 – 0.127134 0.0021189 0.0036 0.00006 3.6 0.06
ft3/hr 471.9474 7.86579 – 0.0166667 0.0283168 0.0004719 28.31685 0.4719474
ft3/min 28,316.85 471.9474 60 – 1.699008 0.0283168 1699.008 28.31685
m3/hr 16,666.67 277.7778 35.31467 0.5885777 – 0.0166667 1000 16.66667
m3/min 1,000,000 16,666.67 2118.876 35.31467 60 – 60,000 1000
L/hr 16.66667 0.2777778 0.0353147 0.0005885 0.001 0.0000167 – 0.0166667
L/min 1000 16.66667 2.118876 0.0353147 0.06 0.001 60 –

Length To Obtain

Å cm ft in m mm micron yd
1-877-PRAXAIR

Multiply By
-8 -10
Å – 1 x 10 3.2808399 x 10 3.3937008 x 10-9 1 x 10-10 0.0000001 0.0001 1.0936133 x 10-10
8
cm 1 x 10 – 0.0328084 0.3937008 0.01 10 10,000 0.0109361
ft 3.048 x 109 30.48 – 12 0.3048 304.8 304,800 0.3333333
in 2.54 x 108 2.54 0.0833333 – 0.0254 25.4 25,400 0.0277778
m 1 x 1010 100 3.2808399 39.3700787 – 1,000 1,000,000 1.0936133
mm 10,000,000 0.1 0.00328084 0.03937008 0.001 – 1,000 0.0010936
micron 10,000 0.0001 3.2808399 x 10-6 3.9370079 x 10-5 0.0000010 0.001 – 1.0936133 x 10-6
9
yd 9.144 x 10 91.44 3 36 0.9144 914.4 914,400 –

Pressure To Obtain

micron mm of Hg atm psi bar kg/cm2 kPa ft of H2O in of H2O in of Hg


(µm Hg) at 0 oC (torr) at 60 oF at 60 oF at 0 oC

Multiply By
-3 -6 -5
micron (µm Hg) – 1.0 x 10 1.31579 x 10 1.9337 x 10 1.33 x 10-6 1.30 x 10-6 1.333 x 10-4 4.4603 x 10-5 5.3524 x 10-4 3.937 x 10-5
o
mm of Hg (0 C) (torr) 1,000 – 0.00132 0.019337 0.001333 0.001360 0.133322 0.044603 0.535240 0.03937
atm 760,000 760 – 14.696 1.01325 1.0332 101.3171 33.932 407.1827 29.921
psi 51,714 51.715 0.06805 – 0.068948 0.070307 6.89465 2.3089 27.70851 2.0360
bar 750,187 750.062 0.98692 14.50368 – 1.019716 100 33.4883 401.8596 29.530
kg/cm2 769,231 735.5592 0.96787 14.22334 0.980665 – 98.03922 32.8084 393.7008 28.95903
kPa 7,501.87 7.5006 0.00987 0.14504 0.010 0.01020 – 0.33456 4.01472 0.2613
ft of H2 O (60 oF) 22,420 22.4198 0.02947 0.433107 0.029891 0.03048 2.9890 – 12 0.882646
F
in of H2O (60 oF) 1,868.32 1.86832 0.00246 0.03609 0.002499 0.00254 0.249089 0.083333 – 0.073556
140
in of Hg (0 oC) 25,400 25.4 0.03342 0.49115 0.033664 0.034532 3.376895 1.1340 13.6 –
GAS HANDLING EQUIPMENT
TECHNICAL DATA
Conversion Factors

Temperature To Obtain
o
Celsius, C Fahrenheit, oF Kelvin, oK Rankine, oR

Multiply By

Celsius, oC – o
F = (oC x 1.8) + 32 o
K = oC + 273.16 o
R = (oC + 273.16) x 1.8
Fahrenheit, oF o
C = (oF - 32)/1.8 – o
K = ((oF -32)/1.8) + 273.16 o
R = oF + 459.69
Kelvin, oK o
C = oK - 273.16 o
F = ((oK - 273.16) x 1.8) + 32 – o
R = oK x 1.8
Rankine, oR o
C = (oR/1.8) - 273.16 o
F = oR - 459.69 o
K = oR/1.8 –

Volume Obtain
3 3 3
cm * ft in m3 gal (U.S. Liquid) L gal (Imperial)

1-877-PRAXAIR
Multiply By

cm3* – 0.00003531 0.0610237 0.000001 0.0002641 0.001 0.0002199


ft3 28,316.847 – 1728 0.02831685 7.480519 28.316847 6.229
in3 16.387064 0.0005787 – 0.00001637 0.0043290 0.0163871 0.003605
m3 1,000,000 35.31467 61,023.74 – 264.172 1000 220.0
gal (U.S. Liquid) 3785.4123 0.13368056 231 0.00378541 – 3.785412 0.8327


L 1000 0.03531467 61.02374 0.001 0.2641721 – 0.2200
gal (Imperial) 4546.10 0.1605 277.40 0.004546 1.201 4.546 –

www.praxair.com/specialtygases
* 1 cm3 = 1 ml

Mass and Weight To Obtain

mg g kg oz* lb* ton (short, U.S.) ton (long, metric)

Multiply By

mg – 0.001 0.000001 3.5274 x 10-5 2.2046 x 10-8 1.102 x 10-9 1 x 10-9


-8
g 1000 – 0.001 0.0352740 0.0022046 1.102 x 10 1 x 10-6
kg 1,000,000 1000 – 35.273962 2.2046226 0.0011023 1 x 10-3
-5
oz* 28,349.5 28.34952 0.0283495 – 0.0625 3.125 x 10 2.83 x 10-5
lb* 453,592 453.59237 0.4535924 16 – 0.0005 4.535 x 10-4
8
ton (short, U.S.) 9.07185 x 10 907.185 907.18474 32,000 2000 – 0.907
ton (long, metric) 1 x 109 1 x 106 1000 35,274 2205 1.102 –
*avoirdupois

Concentration Equivalents Exponential Equivalents


Concentration Equivalent Concentration Equivalent Scientific Equivalent Scientific Equivalent
1,000,000 ppm = 100.00% 1,000 ppb = 1 ppm Notation Notation Notation

100,000 ppm = 10.0% 100 ppb = 0.1 ppm 1 x 1010 10,000,000,000 1 x 10 0 1

10,000 ppm = 1.0% 10 ppb = 0.01 ppm 1 x 109 1,000,000,000 1 x 10 -1 0.1

1,000 ppm = 0.1% 1 ppb = 0.001 ppm 1 x 108 100,000,000 1 x 10 -2 0.01

100 ppm = 0.01% 1 x 107 10,000,000 1 x 10 -3 0.001


1,000 ppt = 0.001ppm
10 ppm = 0.001% 1 x 106 1,000,000 1 x 10 -4 0.0001
100 ppt = 0.0001ppm
1 ppm = 0.0001% 1 x 105 100,000 1 x 10 -5 0.00001
10 ppt = 0.00001ppm
1 x 104 10,000 1 x 10 -6 0.000001
1 ppt = 0.000001ppm
1 x 103 1,000 1 x 10 -7 0.0000001
1,000 ppt = 1 ppb 1 x 102 100 1 x 10 -8 0.00000001
100 ppt = 0.1 ppb 1 x 101 10 1 x 10 -9 0.000000001
10 ppt = 0.01 ppb 1 x 100 1 1 x 10 -10 0.0000000001 F
1 ppt = 0.001 ppb 141
GAS HANDLING EQUIPMENT
TECHNICAL DATA
CGA Connections

Name Chemical CGA High Name Chemical CGA High


Formula Integrity Formula Integrity
Acetylene C 2H 2 510 – Hydrogen bromide HBr 330 634
Air N/A 590 – Hydrogen chloride HCl 330 634
Ammonia NH3 240/705, 720 Hydrogen fluoride HF 670 638
660
Hydrogen sulfide H 2S 330 722
Argon Ar 580 718
Isobutane CH(CH3)3 510 –
Arsine AsH3 350 632
Isobutylene (CH3)2 C:CH2 510 –
Boron trichloride BCl3 660 634
Krypton Kr 580 718
Boron trifluoride BF3 330 642
Methane CH4 350 –
Butadiene, 1,3- CH2:CHCH:CH2 510 –
Methyl bromide CH3Br 330 –
www.praxair.com/specialtygases

Butane, n- C4H10 510 –


Methyl chloride CH3Cl 660 –
Butene, 1- CH3CH2 CH:CH2 510 –
Monomethylamine CH3NH2 240/705 –
Butene, 2- cis CH3CH:CHCH3 510 –
Natural gas N/A 350 –
Butene, 2- trans CH3CH:CHCH3 510 –
Neon Ne 580 718
Carbon dioxide CO2 320 716
Nitric oxide NO 660 –
Carbon monoxide CO 350 724
Nitrogen N2 580 718
Chlorine Cl2 660 728
Nitrogen dioxide NO2 660 –
Deuterium D2 350 –
Nitrogen trifluoride NF3 670, 330 640
Diborane B 2H 6 350 632
Nitrous oxide N 2O 326 712
Dichlorosilane SiH2Cl2 678 636
Oxygen O2 540 714
Dimethyl ether (CH3)2O 510 –

Phosphine PH3 350 632


Dimethylamine (CH3)2NH 240/705 –
Phosphorous PF5 330, 660 642
1-877-PRAXAIR

Disilane (SiH3)2 350 632 pentafluoride


Ethane C 2H 6 350 – Propane C 3H 8 510 –
Ethyl chloride CH3CH2Cl 300 – Propylene CH2 :CHCH3 510 –
Ethylene CH2:CH2 350 – Silane SiH4 350 632
Ethylene oxide C 2H 4O 510 – Silicon tetrachloride SiCl4 330 636
Halocarbon-14 CF4 320 716 Silicon tetraflouride SiF4 330 642
Halocarbon-22 CHClF2 660 – Sulfur dioxide SO2 660 634
Halocarbon-23 CHF3 320 716 Sulfur hexafluoride SF6 590 716
Halocarbon-116 C 2F 6 320 716 Trichlorosilane SiHCl3 678 636
Halocarbon-134A CF3CH2F 660 – Trimethylamine (CH3)3N 240/705 –
Halocarbon-218 C 3F 8 660 716 Tungsten hexafluoride WF6 670 638
Helium He 580 718 Xenon Xe 580 718
Hydrogen H2 350 724

F
142
G

SAFETY INFORMATION
SAFETY In this section . . .
INFORMATION
■ Material Safety Data Sheets

■ Personal protective equipment

■ Receiving cylinders and containers

■ Testing for leaks

■ Moving cylinders and containers

■ Storing cylinders and containers


Safe Practices
Specific guidelines

■ Opening and closing valves

FAX ON DEMAND!!
MSDS’s NOW AVAILABLE,
FAST AND EASY BY CALLING
1-800-PRAXAIR!!
or
VISIT OUR WEBSITE
www.praxair.com/msds
SAFETY

GENERAL SAFETY INFORMATION

Material Safety Data Sheets Personal Protective ■ Cylinders with neck threads should have
a cap in place over the valve. Remove
Equipment
A Material Safety Data Sheet (MSDS) is a the cap by hand. Never use a screwdriv-
er, crowbar, or other leverage device to
fact sheet that lists the characteristics and
The type of personal protective equipment remove the cap. You could accidentally
hazards of a specific hazardous industrial
required at a particular location depends open the valve or damage it.
material. MSDSs tell how to handle, store,
on the products handled at that location.
and ship the material safely and in accor- ■ Check the cylinder valve to be sure it is
For personal protective equipment recom-
dance with regulations. They also give not bent or damaged. A damaged
mendations, read the MSDS for each prod-
emergency and first aid procedures for valve could leak or fail, or it might not
uct handled at your location. Personal pro-
dealing with injuries, fires, leaks, spills, make a tight connection when the cylin-
tective equipment, available from local
and other incidents involving the material. der is placed into use. Make sure the
safety equipment suppliers, should be
Praxair MSDSs also provide additional valve is free of dirt and oil, which could
selected in accordance with standards
information such as ratings under various contaminate the gas. Dirt particles pro-
established by OSHA or NIOSH.
hazard identification systems, listing by pelled in a high- velocity gas stream
certain states, and valve connection data. could cause a spark, igniting a flamma-
Receiving Cylinders and ble gas. Oil and grease can react with
Under the OSHA Hazard Communication Containers oxygen and other oxidizers, causing an
Standard, manufacturers of hazardous explosion.
materials must prepare and make available External Inspection
Personnel responsible for receiving cylin- ■ If any cylinder is received with missing
an MSDS for each hazardous material
or unreadable labels and markings; visi-
sold. In addition, those purchasing these ders and containers should perform an
ble damage; an unstable base; a miss-
materials must maintain a file of MSDSs in external inspection on all packages before
ing cap; or a bent, damaged, or dirty
the work place so they are available to moving them to the point of use or to the
valve, do not use the cylinder. Contact
their employees. storage area. Basic guidelines for perform- your supplier and ask for instructions.
ing this inspection are as follows:
Precautionary information on the safe han-
■ Read the cylinder labels to be sure that
Testing for Leaks
dling of gases listed in this catalog is pro-
vided on Material Safety Data Sheets the gas is what you ordered and that
(MSDS), which are issued to customers for you understand the hazards associated After completing the external inspection,
each product sold. with the product. Remember, the label is proceed as follows:
the only means of identifying the product
in the cylinder. Never identify the prod- ■ Test the cylinder valve for leaks using the
We strongly urge you to read and thor-
uct by the color of the cylinder. leak test method approved by your
oughly understand the information con-
tained in the applicable MSDS before employer. If you detect leakage, follow
■ Check the TC/DOT cylinder markings to your employer's procedures for handling
using any of the gases in this catalog.
be sure you understand the pressures leaking cylinders.
contained in the cylinders.
We also suggest you obtain and read
NOTE: It is normal for cryogenic liquid
Praxair's pamphlets "CONDENSED
■ Thoroughly inspect the cylinders for any containers to vent through their relief valves
SAFETY INFORMATION, Compressed
obvious damage. The cylinder surface to relieve excess pressure build up due to
Gases and Cryogenic Liquids" (Form
should be clean and free from defects heat leak. This venting is not a leak.
P-12-237), and 'GUIDELINES for Handling such as cuts, gouges, burns and obvious
Compressed Gas Cylinders and Liquid dents. Such damage could weaken the ■ If no leakage is detected, secure the
Containers" (Form P-14-153). cylinder metal, creating a danger of fail- cylinder valve cap in place before
Copies of MSDS's and the pamphlets can ure, or it could make the cylinder unsta- moving the cylinder to the point
be obtained thru your Sales Representative, ble and more likely to tip over. Make of use or to the storage area.
by calling Praxair at 1-800-PRAXAIR or sure the cylinder stands steady on its
visiting our website at base and does not wobble.
www.praxair.com/msds.

G
1
SAFETY

GENERAL SAFETY INFORMATION

Moving Cylinders and ■ Gloves to protect the hands against com- NOTE: Valve caps must always be in
mon pinching injuries. place while moving or transporting cylin-
Containers
ders or when they are in storage.
■ Safety glasses to protect the eyes
Cylinders and containers must always be against injuries associated with pressure While moving full or empty cylinders,
moved carefully. Mishandling that results release.
in a damaged valve or ruptured cylinder ■ Always use carts or hand trucks
can expose personnel to the hazards asso- ■ Safety shoes with metatarsal supports to designed for this purpose.
ciated with these gases. In addition, most protect against foot injuries from falling
gas cylinders are heavy and bulky. A cylinders. ■ Never drop cylinders or allow them to
cylinder striking someone or pinching a fin- strike each other violently.
ger, toe, or other extremity is a common Before moving a cylinder to the storage
cause of injury. For these reasons, all area or point of use or before returning the ■ Never lift cylinders by the cap or with
cylinder handlers must always wear certain cylinder to the supplier, ensure the follow- a lifting magnet.
minimum personal protective equipment ing:
prescribed by OSHA: After moving a cylinder to its point of use,
■ The outlet valve is fully closed. secure the cylinder in place. Use cylinder
stands, clamps, or other securing devices
■ The outlet valve dust plug or pressure recommended by your supplier.
cap is on tight for cylinders equipped
with these protection devices.

■ The valve protection cap is properly


secured in place on cylinders with neck
threads.

Storing Cylinders and Safe Practices Keep stored cylinders out of high traffic
areas. Do not store them near the edges of
Containers
In general, store cylinders so they can’t be platforms. Avoid storage in areas where
easily toppled over. Remember, danger there are activities that could damage or
Storage of compressed gas cylinders and
exists not only from accidental release of contaminate the cylinders. Electric arc
cryogenic liquid containers is governed by
gas by cylinders damaged in a fall but welding can destroy the integrity of cylin-
codes of the National Fire Protection
also from their striking someone and caus- der metal if a welder carelessly strikes an
Association (NFPA). Local codes may also
ing injury. Store cylinders upright in com- arc on a cylinder. Overhead hoists can
apply. Know and obey codes governing
pact groups, interlocking them so that each drip oil or grease on cylinders, contaminat-
storage at your location.
cylinder physically contacts those around it. ing them. Never store cylinders with flam-
Do not stand cylinders loosely or in a hap- mable materials.
hazard manner. A single cylinder that top-
ples over can create a domino effect caus-
ing other cylinders to fall. Single cylinders
should be secured in place or on a cylinder
cart so they can’t be readily knocked over.

G
2
SAFETY

GENERAL SAFETY INFORMATION

Specific Guidelines ■ Nonflammable, Non-corrosive, Low Toxicity (Table 1)


■ Flammable, Non-corrosive, Low Toxicity (Table 2)
The compressed gases and cryogenic liq- ■ Flammable, Corrosive, and/or Toxic (Table 3)
uids presented on the following pages are ■ Toxic and/or Corrosive, Nonflammable (Table 4)
organized in product categories having ■ Spontaneously Flammable (Table 5)
similar health hazards and storage require- ■ Toxic (Table 6)
ments. These categories are as follows:

Table 1
Nonflammable, Non-corrosive, Low Toxicity Air Halocarbon 116 Note: Nonflammable, Non-corrosive, Low
Store these products in well-ventilated areas or in Argon Halocarbon 218 Toxicity products listed in Table 1 can be
covered outdoors areas, keeping them off the Banana Gas 32 Halocarbon 134A safely stored together with Toxic and/or
ground and away from radiant heat sources. Carbon Dioxide Helium Corrosive, Nonflammable products listed in
Cylinder temperatures should not exceed Clinical Blood Gas Mixtures Krypton Table 4.
125°F (52°C). P-5 Electron Capture Mixture Neon
Electron Capture Mixture, Nitrogen
8.5% Hydrogen/Helium Nitrous Oxide
Halocarbon 14 Oxygen
Halocarbon 22 Sulfur Hexafluoride
Halocarbon 23 Xenon

Table 2
Flammable, Non-corrosive, Low Toxicity Acetylene Isobutane Note: Flammable, Non-corrosive, Low
Store these products in well-ventilated areas Butane Isobutylene Toxicity products listed in Table 2 can be
equipped with electrical equipment in accor- Deuterium Methane safely stored together with Flammable,
dance with Article 500 of the National Electrical Ethane Propane Corrosive, and /or Toxic products listed in
Code. These products may also be stored in cov- Ethylene Propylene Table 3.
ered outdoor areas, but keep them off the ground Hexane Toluene
and away from radiant heat sources. Keep all 1-Hexene Xylenes(o-,m-,p-)
ignition sources and combustible materials out of Hydrogen
the storage area. Cylinder temperature should
not exceed 125°F (52°C).

Table 3
Flammable, Corrosive, And/Or Toxic 1,3-Butadiene Ethylene Oxide Note: Flammable, Corrosive, and/or
Store these products in well-ventilated areas Carbon Monoxide Hydrogen Sulfide Toxic products listed in Table 3 can be
equipped with electrical equipment in accor- Carboxide, 10% Ethylene Methyl Bromide safely stored together with Flammable,
dance with Article 500 of the National Electrical Oxide – 90% Carbon Methyl Chloride Non-corrosive, Low Toxicity products listed
Code. These products may also be stored in cov- Dioxide Mixture Monomethylamine in Table 2.
ered outdoor areas, but keep them off the ground Dichlorosilane TEOS
and away from radiant heat sources. Keep all Dimethylamine Trichlorosilane
ignition sources and combustible materials out of Ethyl Chloride Trimethylamine
the storage area. Cylinder temperature should
not exceed 125°F (52°C).

G
3
SAFETY

GENERAL SAFETY INFORMATION

Table 4
Toxic And/Or Corrosive, Nonflammable Ammonia Sulfur Dioxide Note: Toxic and/or Corrosive, Nonflammable
Store these products in well-ventilated areas or in Boron Trichloride Hydrogen Fluoride products listed in Table 4 can be safely stored
covered outdoor areas, but keep them off the Boron Trifluoride Nitrogen Trifluoride together with Nonflammable, Non-Corrosive,
ground and away from radiant heat sources. Boron11 Trifluoride Nitrous Oxide Low Toxicity products listed in Table 1.
Cylinder temperature should not exceed 125°F Chlorine Phosphorous
(52°C). Hydrogen Bromide Pentafluoride
Hydrogen Chloride Silicon Tetrachloride

Table 5
Spontaneously Flammable Disilane WARNING: Do not store Spontaneously
Store these products in well-ventilated areas or in Silane Flammable products with products in any other
covered outdoor areas, but keep it off the ground Trimethylboron hazard category.
and away from radiant heat sources. Keep com-
bustible materials out of the storage area.
Cylinder temperatures should not exceed 125°F
(52°C).

Table 6
Toxic Arsine Germanium Tetraflouride WARNING: Do not store Toxic products with
These products are very toxic. The slightest Chlorine Trifluoride Hydrogen Selenide products in any other hazard category.
exposure to these products can kill. Preferably, Diborane Nitric Oxide
store these toxic gases outdoors in a fenced-in Diethyltelluride- Nitrogen Dioxide
area that has been locked and posted. This area Hydrogen Mixtures Phosphine
must be covered with the cylinders kept off the Germane Tungsten Hexafluoride
ground and away from radiant heat sources. If
stored indoors, toxic gas cylinders must be kept
in well-ventilated areas.

In addition to being toxic, arsine, diborane, and


phosphine are also flammable. The storage area
for flammable toxic gases should have electrical
equipment conforming to Article 500 of the
National Electrical Code.
Space all ignition sources and combustible mate-
rials out of storage areas.

G
4
SAFETY

GENERAL SAFETY INFORMATION

Opening and Closing Valves gradually adjust to full pressure. Stop turn- Packed Stem Valve 30 to 40 ft-lb
Observing a few simple rules when opening ing as soon as there is any resistance. Diaphragm Seal Valve 85 to 96 in-lb
and closing valves can prevent damage to Turning the valve handle or stem too far in Pressure Seal Valve 60 to 85 in-lb
valves and equipment and add years of the open position can jam the stem causing Pin-Indexed Valve 20 to 25 in-lb
useful service life to the valves. The proper damage and leaks and preventing later
way to open any cylinder valve is to first closure. Likewise, overtightening when
crack the valve, then open it slowly by turn- closing a valve can damage or permanent-
ing the handle or stem counterclockwise ly distort the seat and result in leakage.
(see Figure 1). This allows equipment to Typical closing torques are as follows:

Figure 1

G
5
SAFETY

GET TO KNOW PRAXAIR SPECIALTY GASES

Get to know
Praxair Specialty
Gases &
Equipment
Comprehensive, High
Quality Product Line
A full range of certified gases,
mixtures, gas handling equip-
ment and related services.

Application-Based
Solutions
Sales, production and research
capabilities and the ability to
supply end use customers,
OEMs and research institutes
with a safe, accurate and pre-
cise product worldwide.

Reliable Production and


Distribution Network
Seventeen specialty gases labo-
ratories and production centers,
more than 600 distribution
locations in North America and
Praxair’s own delivery fleet —
all serving you with the gases
you need when you need them.

Outstanding Technical
Support
A highly trained team of field
sales representatives, technical
service personnel and produc-
tion chemists, in concert with
dedicated market specialists
who quickly provide the guid-
ance and support our prospects
and customers need to resolve
regulatory, technical and safety
application issues.

Worldwide Coverage
Application-based research and
development at five internation-
al technical centers, combined
with specialty gases production
and distribution in over 40
countries.

G
6
TECHNICAL DATA
H
TECHNICAL In this section . . .
DATA
■ Materials Compatibility

■ Conversion Factors
Density
Flow
Length
Pressure
Temperature
Volume
Mass Weight
Concentration Equivalents

■ Dew Points

■ Miscellaneous physical constants

■ Physical properties

■ CGA connections

■ Glossary
TECHNICAL DATA

MATERIALS COMPATIBILITY

Gas Compatibility Directions


The compatibility data *shown on the To use this chart, proceed as follows:
following pages has been completed by 1. Locate the gas you are using in the first
Praxair to assist in evaluating the column.
appropriate materials to use in handling 2. Compare the materials of construction
various gases. It is extremely important for the equipment you intend to use with
that all gas control equipment be com- the “materials of construction” shown in
patible with the gas being passed the Compatibility Chart. Then use the
“Key to Materials Compatibility” to
through it. The use of a device that is
determine compatibility.
not compatible with the gas being used
may damage the unit and cause a leak Key to Materials Compatibility
that could result in property damage or
personal injury. To reduce potentially S - Satisfactory for use with the intended gas. C4-Satisfactory with brass, except where
dangerous situations, always check for U - Unsatisfactory for use with the intended gas. acetylene or acetylides are present.
the compatibility of materials before C1 thru C7 - Conditionally acceptable for C5-Generally unsatisfactory, except where
using any gases in your gas control use with the intended gas as follows: specific use conditions have proven
acceptable.
equipment. C1-Satisfactory with brass having a low
(65-70% maximum) copper content. C6-Satisfactory below 1000 psig.
Since combinations of gases are Brass with higher copper content is C7-Satisfactory below 1000 psig where
virtually unlimited, mixtures (except unacceptable. gas velocities do not exceed 30 ft /sec.
for Oxyfume®, MedifumeTM and C2-Satisfactory with acetylene; however, I - Insufficient data available to determine
Carboxide® sterilizing gas mixtures) cylinder acetylene is packaged dis- compatibility with the intended gas.
solved in a solvent (generally acetone)
are not listed in the Compatibility *This chart has been prepared for use with dry
which may be incompatible with these
Chart. Before using a gas mixture or (anhydrous) gases at normal operating temperature
elastomers. of 70OF (21OC). Information may vary if different
any gas not listed in the chart, we operating conditions exist. Systems and equipment
C3-Compatibility varies depending on
strongly urge you to contact Praxair used in oxidizer gas service (e.g., Oxygen or
specific Kalrez® compound used. Nitrous Oxide) must be cleaned for oxidizer service.
for information. Consult E. I. DuPont for information
on specific applications.

Important
This information is for experienced opera- Compressed Gas Cylinders and Cryo- information with respect to the products
tors who know the general principles and genic Liquid Containers” (P-14-153). mentioned; and, therefore, it is not to be
the safety precautions to be observed in These publications are available from taken as a warranty or representation for
handling specialty gases and associated your Praxair representative. which Praxair assumes legal responsibility.
equipment. If you are not certain you fully The information contained in the Compati- Since the user’s product formulation, spe-
understand these safety precautions, we bility Chart has been compiled by Praxair cific use application, and conditions of
urge you to obtain and read the applica- from what it believes are authoritative use are all outside Praxair’s control,
ble Material Safety Data Sheet (MSDS) sources and it is offered solely as a con- Praxair makes no warranty or representa-
and Equipment Instruction Booklet. We venience to its customers. While Praxair tion regarding the result which may be
also urge you to obtain and read Praxair’s believes that this information is accurate obtained by the user. It shall be the
booklets, “Condensed Safety Information, and factual as of the date of this publica- responsibility of the user to determine the
Compressed Gases and Cryogenic Liquid” tion, this information is intended to be suitability of the user’s gas control equip-
(P-12-237) and “Guidelines for Handling used only as a guide in providing general ment for use with the products mentioned.

H
1
TECHNICAL DATA

MATERIALS COMPATIBILITY

Compatibility Chart Materials of Construction


Metals Plastics Elastomers

Polycarbonate
Stainless Steel

Polyurethane
Carbon Steel

Aluminum

Neoprene
Buna-N
Copper

Kalraz
Monel

Kynar
Teflon
Brass

Tefzel

Viton
Kel-F
Zinc
Common Name Chemical

PVC
Formula

Acetylene C2H2 C1 S S S U U S S S S S I I S C2 C2 C2 C2

Air ----- S S S S S S S S S S S S S S S S S S

Ammonia NH3 U S S S U U S S S S U S U C3 U S S U

Argon Ar S S S S S S S S S S S S S S S S S S

Arsine AsH3 S S S C5 I S S S S S S S I S S S S U

Boron Trichloride BCl3 U S S U I S S S S S S S I C3 I I I I

Boron Trifluoride BF3 S S S C5 I S S S S S S S I C3 I I I I

1,3-Butadiene C4H6 S S S S S S S S S S S S U S S U S U

Butane C4H10 S S S S S S S S S S S S U S S S S S

1-Butene C4H8 S S S S S S S S S S S S U S S S S S

Cis-2-Butene C4H8 S S S S S S S S S S S S U S S S S S

Trans-2-Butene C4H8 S S S S S S S S S S S S U S S S S S

Carbon Dioxide CO2 S S S S S S S S S S S S S S S S S S

Carbon Monoxide CO S S S S S S S S S S S S S S I S S S

Carboxide®/MedifumeTM ----- C4 S S I I U I S S I I U U C3 U U U U

Chlorine Cl2 U S S U U U S S S S S U U S S U U U

Deuterium D2 S S S S S S S S S S S S I S S S S S

Diborane B2H6 S S S S I S S S S S S S I S I I I I

H
2
TECHNICAL DATA

MATERIALS COMPATIBILITY

Compatibility Chart Materials of Construction


Metals Plastics Elastomers

Polycarbonate
Stainless Steel

Polyurethane
Carbon Steel

Aluminum

Neoprene
Buna-N
Copper

Kalraz
Monel

Kynar
Teflon
Brass

Tefzel

Viton
Kel-F
Zinc
Common Name Chemical

PVC
Formula

Dichlorosilane H2SiCl2 S S S U I S S S S S S I I S I I I I

Dimethyl Ether C2H6O S S S S S S S S S S S S U S S S S I

Dimethylamine (CH3)2NH U S S U U U S S S I U S I I U U S I

Disilane Si2H6 S S S I I S S S S S S S U I S I S I

Ethane C2H6 S S S S S S S S S S S S I S S S S S

Ethyl Chloride C2H5Cl S S S U I S S S S S S U U S S S S U

Ethylene C2H4 S S S S S S S S S S S I I S S S S I

Ethylene Oxide C2H4O C4 S S C5 I U I S S I I U U C3 U U U U

Halocarbon 14 CF4 S S S S I S S S S S S U U C3 S S S S

Halocarbon 22 CHCIF2 S S S C5 I S S S S S S U U C3 U U S U

Halocarbon 23 CHF3 S S S C5 I S S S S S S U U C3 I I I S

Halocarbon 116 C2F6 S S S S S S S S S S S U U C3 I I I S

Halocarbon 134A CH2FCF3 S S S C5 I S S I I I I I I I I U U I

Halocarbon 218 C3F8 S S S C5 I S S S S S I I I I I I I I

Helium He S S S S S S S S S S S S S S S S S S

Hydrogen H2 S S S S S S S S S S S S S S S S S S

Hydrogen Bromide HBr U S S U U U S S S I S S I I S U U I

Hydrogen Chloride HCl U S S U U U S S S S S S U S S U U U

H
3
TECHNICAL DATA

MATERIALS COMPATIBILITY

Compatibility Chart Materials of Construction


Metals Plastics Elastomers

Polycarbonate
Stainless Steel

Polyurethane
Carbon Steel

Aluminum

Neoprene
Buna-N
Copper

Kalraz
Monel

Kynar
Teflon
Brass

Tefzel

Viton
Kel-F
Zinc
Common Name Chemical

PVC
Formula

Hydrogen Fluoride HF U S S U U U S S S I S S I I S U U I

Hydrogen Sulfide H2S U S S S I I S S S S S S S S U S S S

Isobutane C4H10 S S S S S S S S S S S S U S S S S S

Isobutylene C4H8 S S S S I S S S S S S S I S S S S I

Krypton Kr S S S S S S S S S S S S S S S S S S

Methane CH4 S S S S S S S S S S S S I S S S S S

Methyl Bromide CH3Br C5 S S U I U U S S I I I I I S U U I

Methyl Chloride CH3Cl S S S U U S S S S S S I I S S U U U

Monomethylamine CH3NH2 U S S C5 U U S I S I U I I I S S S I

Natural Gas (Dry) ----- S S S S S S S S S S S S I S S S S S

Neon Ne S S S S S S S S S S S S S S S S S S

Nitric Oxide NO U S S S I S S S S S I S I S I I S I

Nitrogen N2 S S S S S S S S S S S S S S S S S S

Nitrogen Dioxide NO2 U S S S I U S S S S I U I S U U U U

Nitrogen Trifluoride NF3 C5 C5 S U U C5 S S S I S I I I I I I I

Nitrous Oxide N2O S S C6 C6 S S S S C5 S S S I C3 S S S S

Oxygen O2 S C7 C7 C7 S S S S C5 S S S S C3 S U U S

Oxyfume® Mixtures ----- C4 S S I I U I S S I I U U C3 U U U U

H
4
TECHNICAL DATA

MATERIALS COMPATIBILITY

Compatibility Chart Materials of Construction


Metals Plastics Elastomers

Polycarbonate
Stainless Steel

Polyurethane
Carbon Steel

Aluminum

Neoprene
Buna-N
Copper

Kalraz
Monel

Kynar
Teflon
Brass

Tefzel

Viton
Kel-F
Zinc
Common Name Chemical

PVC
Formula

Phosphine PH3 S S S S I I S S S S I I I S I I I I

Phosphorous
Pentafluoride PF5 I S S I I I S S S I S I I S S S S S

Propane C3H8 S S S S S S S S S S S S U S S S S S

Propylene C3H6 S S S S S S S S S S S S U S S U U U

Refrigerant Gases ----- See Halocarbons

Silane SiH4 S S S S I S S S S S S S I S S S S S

Silicon Tetrachloride SiCl4 I S S U I U S S S I I U I C3 I I I I

Silicon Tetrafluoride SiF4 S S S S I S S S S S S S I C3 S S S S

Sulfur Dioxide SO2 U S S C5 U U S S S S S S U S S U U S

Sulfur Hexafluoride SF6 S S S S I S S S S S S S I C3 S S S S

Trichlorosilane HSiCl3 S S S U I I S S S I I U I C3 I I I I

Trimethylamine (CH3)3N U S S U U U S S S S U S I I U U S I

Tungsten
Hexafluoride WF6 U C5 S U U U S I S S S S I I U U U I

Xenon Xe S S S S S S S S S S S S S S S S S S

H
5
TECHNICAL DATA

CONVERSION FACTORS

Density To Obtain
3 3
g/ml kg/m lb/ft lb/in3 lb/U.S. gal

Multiply By

g/ml ---- 1000 62.428 0.0361273 8.3454


kg/m3 0.001 ---- 0.062428 3.61273 x 10
-5
0.0083454
3
lb/ft 0.0160185 16.018463 ---- 5.78704 x 10-4 0.13368
lb/in3 27.679905 27,679.9 1728 ---- 231
lb/U.S. gal 0.1198264 119.8264 7.4805195 0.004329 ----

Flow To Obtain
3 3 3 3 3 3
cm /min cm /sec ft /hr ft /min m /hr m /min L/hr L/min

Multiply By

cm3/min ---- 0.0166667 0.0021189 0.0000353 0.00006 0.000001 0.06 0.001


cm3/sec 60 ---- 0.127134 0.0021189 0.0036 0.00006 3.6 0.06
3
ft /hr 471.9474 7.86579 ---- 0.0166667 0.0283168 0.0004719 28.31685 0.4719474
3
ft /min 28,316.85 471.9474 60 ---- 1.699008 0.0283168 1699.008 28.31685
m3/hr 16,666.67 277.7778 35.31467 0.5885777 ---- 0.0166667 1000 16.66667
3
m /min 1,000,000 16,666.67 2118.876 35.31467 60 ---- 60,000 1000
L/hr 16.66667 0.2777778 0.0353147 0.0005885 0.001 0.0000167 ---- 0.0166667
L/min 1000 16.66667 2.118876 0.0353147 0.06 0.001 60 ----

Length To Obtain
Å cm ft in m mm micron yd

Multiply By

Å ---- 1 x 10-8 3.2808399 x 10-10 3.3937008 x 10-9 1 x 10-10 0.0000001 0.0001 1.0936133 x 10-10
cm 1 x 108 ---- 0.0328084 0.3937008 0.01 10 10,000 0.0109361
ft 3.048 x 109 30.48 ---- 12 0.3048 304.8 304,800 0.3333333
8
in 2.54 x 10 2.54 0.0833333 ---- 0.0254 25.4 25,400 0.0277778
m 1 x 1010 100 3.2808399 39.3700787 ---- 1,000 1,000,000 1.0936133
mm 10,000,000 0.1 0.00328084 0.03937008 0.001 ---- 1,000 0.0010936
-6 -5 -6
micron 10,000 0.0001 3.2808399 x 10 3.9370079 x 10 0.0000010 0.001 ---- 1.0936133 x 10
yd 9.144 x 109 91.44 3 36 0.9144 914.4 914,400 ----

H
6
TECHNICAL DATA

CONVERSION FACTORS

Pressure To Obtain
micron mm of Hg atm psi bar kg/cm2 kPa ft of H2O in of H2O in of Hg
(µm Hg) at 0°C (torr) at 60°F at 60°F at 0°C
Multiply By

-3 -6 -5 -6 -6 -4 -5 -4 -5
micron (µm Hg) ---- 1.0 x 10 1.31579 x 10 1.9337 x 10 1.33 x 10 1.30 x 10 1.333 x 10 4.4603 x 10 5.3524 x 10 3.937 x 10
mmof Hg(0°C)(torr) 1,000 ---- 0.00132 0.019337 0.001333 0.001360 0.133322 0.044603 0.535240 0.03937
atm 760,000 760 ---- 14.696 1.01325 1.0332 101.3171 33.932 407.1827 29.921
psi 51,714 51.715 0.06805 ---- 0.068948 0.070307 6.89465 2.3089 27.70851 2.0360
bar 750,187 750.062 0.98692 14.50368 ---- 1.019716 100 33.4883 401.8596 29.530
2
kg/cm 769,231 735.5592 0.96787 14.22334 0.980665 ---- 98.03922 32.8084 393.7008 28.95903
kPa 7,501.87 7.5006 0.00987 0.14504 0.010 0.01020 ---- 0.33456 4.01472 0.2613
ft of H2O (60°F) 22,420 22.4198 0.02947 0.433107 0.029891 0.03048 2.9890 ---- 12 0.882646
in of H2O (60°F) 1,868.32 1.86832 0.00246 0.03609 0.002499 0.00254 0.249089 0.083333 ---- 0.073556
in of Hg (0°C) 25,400 25.4 0.03342 0.49115 0.033664 0.034532 3.376895 1.1340 13.6 ----

Temperature To Obtain
Celsius, oC Fahrenheit, o F Kelvin, o K Rankine, o R

Multiply By

Celsius, o C — o
F = (o C x 1.8) + 32 o
K = o C + 273.16 o
R = (o C + 273.16) x 1.8

Fahrenheit, o F o
C = (o F - 32)/1.8 — o
K = ((o F -32)/1.8) + 273.16 o
R = o F + 459.69

Kelvin, o K o
C = o K - 273.16 o
F = ((o K - 273.16) x 1.8) + 32 — o
R = o K x 1.8

Rankine, o R o
C = (o R/1.8) - 273.16 o
F = o R - 459.69 o
K = o R/1.8 —

To Obtain
Volume gal gal
cm *
3
ft3 in3 m3 (U.S. Liquid) L (Imperial)

Multiply By

cm3* ---- 0.00003531 0.0610237 0.000001 0.0002641 0.001 0.0002199


ft3 28,316.847 ---- 1728 0.02831685 7.480519 28.316847 6.229
3
in 16.387064 0.0005787 ---- 0.00001637 0.0043290 0.0163871 0.003605
3
m 1,000,000 35.31467 61,023.74 ---- 264.172 1000 220.0
gal (U.S. Liquid) 3785.4123 0.13368056 231 0.00378541 ---- 3.785412 0.8327
L 1000 0.03531467 61.02374 0.001 0.2641721 ---- 0.2200
gal (Imperial) 4546.10 0.1605 277.40 0.004546 1.201 4.546 ----

3
*1 cm = 1ml

H
7
TECHNICAL DATA

CONVERSION FACTORS

Mass and To Obtain


Weight ton ton
mg g kg oz* lb* (short, U.S.) (long, metric)
Multiply By

mg ---- 0.001 0.000001 3.5274 x 10-5 2.2046 x 10-8 1.102 x 10-9 1 x 10-9
-8 -6
g 1000 ---- 0.001 0.0352740 0.0022046 1.102 x 10 1 x 10
-3
kg 1,000,000 1000 ---- 35.273962 2.2046226 0.0011023 1 x 10
-5 -5
oz* 28,349.5 28.34952 0.0283495 ---- 0.0625 3.125 x 10 2.83 x 10
-4
lb* 453,592 453.59237 0.4535924 16 ---- 0.0005 4.535 x 10
ton (short, U.S.) 9.07185 x 108 907.185 907.18474 32,000 2000 ---- 0.907
1 x 109 6
ton (long, metric) 1 x 10 1000 35,274 2205 1.102 ----

*avoirdupois

Concentration Equivalents Exponential Equivalents

Concentration Equivalent Scientific Equivalent Scientific Equivalent


Notation Notation Notation

1,000,000 ppm = 100.00%


100,000 ppm = 10.0% 1 x 1010 10,000,000,000 1 x 100 1
9
10,000 ppm = 1.0% 1 x 10 1,000,000,000 1 x 10-1 0.1
1,000 ppm = 0.1% 1 x 108 100,000,000 1 x 10-2 0.01
100 ppm = 0.01% 1 x 107 10,000,000 1 x 10-3 0.001
6
10 ppm = 0.001% 1 x 10 1,000,000 1 x 10-4 0.0001
1 ppm = 0.0001% 1 x 105 100,000 1 x 10-5 0.00001
1 x 104 10,000 1 x 10-6 0.000001
3 -7
1,000 ppb = 1 ppm 1 x 10 1,000 1 x 10 0.0000001
2
100 ppb = 0.1 ppm 1 x 10 100 1 x 10-8 0.00000001
10 ppb = 0.01 ppm 1 x 101 10 1 x 10-9 0.000000001
1 ppb = 0.001 ppm 1 x 100 1 1 x 10-10 0.0000000001

1,000 ppt = 0.001ppm


100 ppt = 0.0001ppm
10 ppt = 0.00001ppm
1 ppt = 0.000001ppm

1,000 ppt = 1 ppb


100 ppt = 0.1 ppb
10 ppt = 0.01 ppb
1 ppt = 0.001 ppb

H
8
TECHNICAL DATA

DEW POINT

Dew Point vs. Parts per Million*


Dewpoint Dewpoint Dewpoint

°F °C ppm °F °C ppm °F °C ppm

-130 -90.0 0.10 -73 -58.0 13.3 -38 -38.9 144


-120 -84.0 0.25 -72 -58.0 14.3 -37 -38.3 153
-110 -79.0 0.63 -71 -57.0 15.4 -36 -37.8 164
-105 -76.0 1.00 -70 -57.0 16.6 -35 -37.2 174
-104 -76.0 1.08 -69 -56.0 17.9 -34 -36.7 185
-103 -75.0 1.18 -68 -56.0 19.2 -33 -36.1 196
-102 -74.0 1.29 -67 -55.0 20.6 -32 -35.6 210
-101 -74.0 1.40 -66 -54.0 22.1 -31 -35.0 222
-100 -73.0 1.53 -65 -54.0 23.6 -30 -34.4 235
-99 -73.0 1.66 -64 -53.0 25.6 -29 -33.9 250
-98 -72.0 1.81 -63 -53.0 27.5 -28 -33.3 265
-97 -72.0 1.96 -62 -52.0 29.4 27 -32.8 283
-96 -71.0 2.15 -61 -52.0 31.7 -26 -32.2 300
-95 -71.0 2.35 -60 -51.0 34.0 -25 -31.7 317
-94 -70.0 2.54 -59 -51.0 36.5 -24 -31.1 338
-93 -69.0 2.76 -58 -50.0 39.0 -23 -30.6 358
-92 -69.0 3.00 -57 -49.0 41.8 -22 -30.0 378
-91 -68.0 3.28 -56 -49.0 44.6 -21 -29.5 400
-90 -68.0 3.53 -55 -48.0 48 -20 -28.9 422
-89 -67.0 3.84 -54 -48.0 51 -19 -28.4 448
-88 -67.0 4.15 -53 -47.0 55 -18 -27.8 475
-87 -66.0 4.50 -52 -47.0 59 -17 -27.2 500
-86 -66.0 4.78 -51 -46.0 62 -16 -26.7 530
-85 -65.0 5.3 -50 -46.0 67 -15 -26.1 560
-84 -64.0 5.7 -49 -45.0 72 -14 -25.6 590
-83 -64.0 6.2 -48 -44.0 76 -13 -25.0 630
-82 -63.0 6.6 -47 -44.0 82 -12 -24.4 660
-81 -63.0 7.2 -46 -43.0 87 -11 -23.9 700
-80 -62.0 7.8 -45 -42.8 92 -10 -23.3 740
-79 -62.0 8.4 -44 -42.2 98 -9 -22.8 780
-78 -61.0 9.1 -43 -41.7 105 -8 -22.2 820
-77 -61.0 9.8 -42 -41.1 113 -7 -21.7 870
-76 -60.0 10.5 -41 -40.6 119 -6 -21.1 920
-75 -59.0 11.4 -40 -40.0 128 -5 -20.6 970
-74 -59.0 12.3 -39 -39.4 136 -4 -20.0 1,020

* @ 760 Torr

H
9
TECHNICAL DATA

MISCELLANEOUS PHYSICAL CONSTANTS

Miscellaneous Physical Constants


NUMERICAL CONSTANT VALUE UNITS
Avogadro’s Number 6.022045x1023 Molecules/g-mole
Gas-Law Constant R 1.98719 cal/(g-mole)(˚K)
1.98719 Btu/(lb-mole)(˚R)
82.0568 (cm3)(atm)/(g-mole)(˚K)
0.0820568 (liter)(atm)/(g-mole)(˚K)
10.7314 (ft3)(lb)/(in2)(lb-mole)(˚R)
0.730228 (ft3)(atm)/(lb-mole)(˚R)
8.314510 (kPa) (L) / (g-mol) (˚K)
8314.5100 (Pa) (L) / (g-mol) (˚K)
0.0831451 (bar) (L) / (g-mol) (˚K)

*Unless otherwise noted mol=g-mol

Volume of Ideal Gas


Conditions Volume, L Volume, m3

0 O C, 1 atm. 22.414 0.022414


15 O C, 1 atm. 23.645 0.023645
70 O F, 1 atm. 24.146 0.024146
NTP (U.S.) 70 O F, 1 atm.
STP (U.S.) 0 O C, 1 atm.

V T n atm psi mm Hg cm Hg in Hg in H2O ft H2O


ft 3
˚K mol 0.00290 0.0426 2.20 0.220 0.0867 1.18 0.0982

lb-mol 1.31 19.31 999 99.9 39.3 535 44.6

˚R mol 0.00161 0.02366 1.22 0.122 0.0482 0.655 0.0546

lb-mol 0.730 10.73 555 55.5 21.8 297 24.8

cm3 ˚K mol 82.05 1,206 62,400 6,240 2,450 33,400 2,780

lb-mol 37,200 547,000 2.83E+07 2.83E+06 1.11E+06 1.51E+07 1.26E+06

˚R mol 45.6 670 34,600 3,460 1,360 18,500 1,550

lb-mol 20,700 304,000 1.57E+07 1.57E+06 619,000 8.41E+06 701,000

L ˚K mol 0.08205 1.206 62.4 6.24 2.45 33.4 2.78

lb-mol 37.2 547 28,300 2,830 1,113 15,140 1,262

˚R mol 0.0456 0.670 34.6 3.46 1.36 18.5 1.55

lb-mol 20.7 304 15,700 1,570 619 8,410 701

This table gives the appropriate value of R for use in the ideal gas equation, PV=nRT, when the
variable are expressed in other units.

*Unless otherwise noted mol=g-mol


H
10
TECHNICAL DATA

PHYSICAL PROPERTIES OF GASES

Physical Properties of Gases

Physical Property Equivalents of Gases

H
11
H
12
Gas Density Boiling Point Critical Press Critical Temp Specific Volume Specific Gravity
Name #/ft3 kg/m3 °F °C psia kg/cm2 °F °C Mole Wt. ft3/# m3/kg (air=1)

Acetylene 0.0733 a 1.17 a-119.2 -84.0 897.8 63.1 95.36 35.20 26.04 14.43 0.901 0.9080
Air 0.0807 a 1.29 a-317.8 -194.4 547.4 38.5 -221.08 -140.60 28.85 13.30 0.830 1.0000
Ammonia 0.0450 0.72 -28.1 -33.4 1636.1 115.0 270.32 132.40 17.03 22.60 1.411 0.5970
Argon 0.1034 1.66 -302.6 -189.4 705.4 49.6 -188.32 -122.40 39.95 9.67 0.604 1.3780
TECHNICAL DATA

Arsine 0.2000 3.20 -80.5 -62.5 957.0 67.3 211.82 99.90 77.95 5.00 0.312 2.6900
PHYSICAL PROPERTIES

Boron trichloride 0.3030 4.85 54.3 12.4 561.4 39.5 353.84 178.80 117.17 3.30 0.206 4.0300
Boron trifluoride 0.1777 2.85 -147.6 -99.8 723.0 50.8 10.04 -12.20 67.81 5.60 0.350 2.3870
Butadiene, 1,3- 0.1516 a 2.43 a 24.1 -4.4 627.5 44.1 305.60 152.00 54.09 6.90 0.431 1.8780
Butane, n- 0.1588 2.54 31.1 -0.5 550.7 38.7 305.60 152.00 58.12 6.40 0.400 2.1100
Butene, 1- 0.1477 b 2.37 b 20.7 -6.3 583.4 41.0 295.52 146.40 56.12 6.70 0.418 2.0000
Butene, 2- (cis) 0.1502 2.41 38.7 3.7 609.9 42.9 324.32 162.40 56.12 6.70 0.418 1.9970
Butene, 2- (trans) 0.1502 2.41 33.6 0.9 595.2 41.8 311.90 155.50 56.12 6.70 0.418 1.9970
Carbon dioxide 0.1140 a 1.83 a -109.1 -78.4 1070.6 75.3 87.80 31.00 44.01 8.76 0.5471. 1.5220
Carbon monoxide 0.0781 a 1.25 a -312.7 -191.5 507.4 35.7 -220.36 -140.20 28.01 13.80 0.862 0.9670
Chlorine 0.1859 2.98 -29.3 -34.1 1118.4 78.6 291.20 144.00 70.91 5.40 0.337 2.4900
Deuterium 0.0112 0.18 -417.1 -249.5 239.2 16.8 -390.82 -234.90 4.03 95.90 5.987 0.1497
Diborane 0.0715 1.15 -134.5 -92.5 581.0 40.8 40.80 62.10 27.67 13.98 0.873 0.9500
Dichlorosilane 0.2601 4.17 46.8 8.2 678.2 47.7 348.80 176.00 101.01 3.83 0.239 3.5200
Dimethyl ether 0.1198 b 1.92 b -12.6 -24.8 764.2 53.7 260.42 126.90 46.07 8.40 0.524 1.6210
Dimethylamine 0.1151 b 1.84 b 44.4 6.9 770.1 54.1 328.28 164.60 45.09 8.60 0.537 1.5570
Disilane 0.1790 2.87 6.3 -14.3 747.2 52.5 303.53 150.85 62.22 6.21 0.388 2.3800
Ethane 0.0775 b 1.24 b -127.5 -88.6 712.8 50.1 90.32 32.40 30.07 12.80 0.799 1.0480
Ethyl chloride 0.1649 b 2.64 b 54.1 12.3 764.2 53.7 368.96 187.20 64.52 6.00 0.375 2.2300
Ethylene 0.0787 a 1.26 a -154.7 -103.7 742.1 52.2 49.82 9.90 28.05 13.80 0.862 0.9750
Ethylene oxide 0.1121 1.80 50.9 10.5 1043.0 73.3 384.44 195.80 44.05 8.78 0.548 1.4900
Halocarbon-14 0.2280 3.65 -198.3 -127.9 542.4 38.1 -49.90 -45.50 88.00 4.39 0.274 3.0380
Halocarbon-22 0.2335 3.74 -41.0 -41.0 721.9 50.8 204.80 96.00 86.47 4.40 0.275 3.1100
Halocarbon-23 0.1820 2.92 -115.6 -82.0 697.0 49.0 78.26 25.70 70.01 5.50 0.343 2.2636
Halocarbon-116 0.3608 5.78 -108.8 -78.2 432.0 30.4 67.50 24.30 138.01 2.80 0.175 4.7730
Halocarbon-134A 0.4683 b 7.50 b -15.7 -26.5 589.6 41.5 213.98 101.10 102.03 2.14 0.134
Halocarbon-218 0.5000 8.01 -34.1 -36.7 388.7 27.3 161.42 71.90 188.02 2.02 0.126 6.6900
Helium 0.0103 0.16 -452.1 -268.9 33.2 2.3 -450.40 -268.00 4.00 96.60 6.031 0.1380

Note: Density: a = 0°C b = 25°C All others at NTP


Gas Density Boiling Point Critical Press Critical Temp Specific Volume Specific Gravity
Name #/ft3 kg/m3 °F °C psia kg/cm2 °F °C Mole Wt. ft3/# m3/kg (air=1)

Hydrogen 0.0050 0.08 -423.0 -252.8 188.1 13.2 -399.82 -239.90 2.02 191.70 11.968 0.0696
Hydrogen bromide 0.2080 3.33 -88.1 -66.7 1234.5 86.8 193.64 89.80 80.92 4.80 0.300 2.7700
Hydrogen chloride 0.0950 1.52 -121.0 -85.0 1197.7 84.2 124.52 51.40 36.46 10.60 0.662 1.2680
Hydrogen fluoride 0.0520 0.83 67.1 19.5 940.5 66.1 370.40 188.00 20.01 19.30 1.205 0.6900
Hydrogen sulfide 0.0890 1.43 -76.5 -60.3 1306.5 91.9 212.72 100.40 34.08 11.23 0.701 1.1890
Isobutane 0.1553 2.49 10.9 -11.7 529.1 37.2 275.00 135.00 58.13 6.50 0.406 2.0640
Isobutylene 0.1440 b 2.31 b 19.6 -6.9 580.2 40.8 292.46 144.70 56.12 6.70 0.418 1.9470
Krypton 0.2170 3.48 -244.1 -153.4 796.5 56.0 -82.84 -63.80 83.80 4.61 0.288 2.8990
Methane 0.0448 a 0.72 a -258.7 -161.5 673.1 47.3 -115.78 -82.10 16.04 23.70 1.480 0.5550
Methyl bromide 0.2464 b 3.95 b 38.4 3.6 757.0 53.2 381.20 194.00 94.94 4.10 0.256 3.3550
Methyl chloride 0.1319 b 2.11 b -11.6 -24.2 2438.1 171.4 289.58 143.10 50.49 7.60 0.474 1.7840
Monomethylamine 0.0813 b 1.30 b 20.7 -6.3 1081.6 76.0 314.42 156.90 31.06 12.10 0.755 1.0800
Natural gas 17.66 24.00 1.498
Neon 0.0520 0.83 -411.0 -246.1 394.7 27.8 -379.66 -228.70 20.18 19.21 1.199 0.6960
Nitric oxide 0.0767 b 1.23 b -241.2 -151.8 949.4 66.7 -135.22 -92.90 30.01 13.00 0.812 1.0360
Nitrogen 0.0725 1.16 -320.4 -195.8 492.2 34.6 -237.82 -149.90 28.01 13.80 0.862 0.9670
Nitrogen dioxide 0.2119 3.39 70.2 21.2 1469.6 103.3 316.76 158.20 46.01 4.70 0.293 2.6200
Nitrogen trifluoride 0.1860 2.98 -200.2 -129.0 657.2 46.2 -38.74 -39.30 71.00 5.40 0.337 2.4600
Nitrous oxide 0.1150 1.84 -127.3 -88.5 1052.2 74.0 97.52 36.40 44.01 8.70 0.543 1.5300
Oxygen 0.0828 1.33 -297.4 -183.0 731.4 51.4 -181.48 -118.60 32.00 12.10 0.755 1.1050
Phosphine 0.0875 1.40 -125.9 -87.7 947.9 66.6 124.88 51.60 34.00 11.40 0.712 1.1840
Phosphorous pentafluoride 0.3340 5.35 -120.1 -84.5 492.3 34.6 66.20 19.00 125.97 3.10 0.194 4.4600
Propane 0.1166 1.87 -43.8 -42.1 618.7 43.5 206.24 96.80 44.11 8.50 0.531 1.5500
Propylene 0.1114 1.79 -53.9 -47.7 667.1 46.9 197.24 91.80 42.08 9.06 0.566 1.4800
Silane 0.0837 1.34 -168.7 -111.5 702.5 49.4 25.88 -3.40 32.12 12.04 0.752 1.1140
Silicon tetrachloride 0.4420 7.08 135.7 57.6 573.3 40.3 454.82 234.90 169.90 2.28 0.142 5.8000
Silicon tetraflouride 0.2684 4.30 -130.4 -90.2 539.0 54.6 6.40 -14.20 104.08 3.70 0.231 1.5900
Sulfur dioxide 0.1666 2.67 14.0 -10.0 1143.5 80.4 315.68 157.60 64.06 5.90 0.368 2.2630
Sulfur hexafluoride 0.3845 6.16 -82.8 -63.8 545.2 38.3 113.90 45.50 146.05 2.50 0.156 5.1100
Trichlorosilane 0.3500 b 5.61 b 89.6 32.0 597.3 42.0 402.08 205.60 135.45 2.85 0.178 4.7000
Trimethylamine 0.1628 2.61 37.2 2.9 590.7 41.5 320.20 160.10 59.11 6.40 0.400 2.0870
Tungsten hexafluoride 0.7930 12.70 67.1 19.5 629.5 44.3 339.44 170.80 297.84 1.24 0.077 10.8000
Xenon 0.3420 5.48 -162.6 -108.1 846.7 59.5 61.88 16.60 131.30 2.90 0.181 4.5600

Note: Density: a = 0°C b = 25°C All others at NTP


PHYSICAL PROPERTIES

H
13
TECHNICAL DATA
TECHNICAL DATA

PHYSICAL PROPERTIES

Chemical 1998 TLV Flammable Range IDLH


Name Formula ppm mg/m3 LEL air UEL air Odor ppm
Acetylene C2H2 Simple Asphyxiant 2.5 100 Ethereal

Air N/A N/A N/A N/A N/A None

Ammonia NH3 25 17 16 25 Pungent, Irritating 300

Argon Ar Simple Asphyxiant Nonflammable None

Arsine AsH3 0.05 0.16 5.1 78 Garlic-like 3

Boron trichloride BCl3 None Established Nonflammable Pungent, Irritating 100

Boron trifluoride BF3 C 1.0 C 2.8 Nonflammable Pungent, Suffocating 25

Butadiene, 1,3- CH2:CHCH:CH2 2.00 4.40 2.0 11.5 Mildly Aromatic 2000

Butane, n- C4H10 800 1900 1.9 8.5 Natural Gas-like

Butene, 1- CH3CH2CH:CH2 None Established 1.6 10.0 Natural Gas-like

Butene, 2- (cis) CH3CH:CHCH3 None Established 1.7 9.0 Natural Gas-like

Butene, 2- (trans) CH3CH:CHCH3 None Established 1.8 9.7 Natural Gas-like

Carbon dioxide CO2 5000 9000 Nonflammable None 40000

Carbon monoxide CO 25 29 12 75 None 1200

Chlorine Cl2 0.50 1.50 Nonflammable Pungent, Irritating 10

Deuterium D2 Simple Asphyxiant 5.0 75 None

Diborane B2H6 0.10 0.15 0.8 98 Repulsive 15

Dichlorosilane SiH2Cl2 None Established 4.7 99 Pungent, Suffocating 100

Dimethyl ether (CH3)2O None Established 3.4 27 Ethereal

Dimethylamine (CH3)2NH 5.00 9.20 2.8 14.4 Fish-like 500

Disilane (SiH3)2 None Established* Unknown, Pyrophoric Repulsive, Choking

Ethane C2H6 Simple Asphyxiant 3.0 12.5 None

Ethyl chloride CH3CH2Cl 100 264 3.8 15.4 Pungent, Ethereal 3800

Ethylene CH2:CH2 Simple Asphyxiant 2.7 36 Sweet

Ethylene oxide C2H4O 1.00 1.80 3.0 100 Ethereal 800

Halocarbon-14 CF4 None Established Nonflammable None

Halocarbon-22 CHClF2 1000 3540 Nonflammable Nearly Odorless

Halocarbon-23 CHF3 None Established Nonflammable None

Halocarbon-116 C2F6 None Established Nonflammable None

Halocarbon-134A CF3CH2F None Established Nonflammable Slight Ethereal

Halocarbon-218 C3F8 None Established Nonflammable Slightly Sweet

Helium He Simple Asphyxiant Nonflammable None

Hydrogen H2 Simple Asphyxiant 4.0 75 None

*Praxair recommends compliance with the 5ppm TLV-TWA for silane

H
14
TECHNICAL DATA

PHYSICAL PROPERTIES

Chemical 1998 TLV Flammable Range IDLH


Name Formula ppm mg/m3 LEL air UEL air Odor ppm
Hydrogen bromide HBr C 3.0 C 9.9 Nonflammable Irritating 30

Hydrogen chloride HCl C 5.0 C 7.5 Nonflammable Pungent, Suffocating 50

Hydrogen fluoride HF C 3.0 C 2.5 Nonflammable Sharp, Irritating 30

Hydrogen sulfide H2S 10 14 4.3 46 Rotten Eggs 100

Isobutane CH(CH3)3 None Established 1.8 8.4 Slight

Isobutylene (CH3)2C:CH2 None Established 1.8 9.6 Coal Gas

Krypton Kr Simple Asphyxiant Nonflammable None

Methane CH4 Simple Asphyxiant 5.0 15 None

Methyl bromide CH3Br 1.00 4.00 10 14.5 Chloroform-like 250

Methyl chloride CH3Cl 50 103 8.1 17.4 Faintly, Sweet Ethereal 2000

Monomethylamine CH3NH2 5.00 9.22 4.9 20.7 Fish-like 100

Natural gas N/A None Established 3.8 17 Natural Gas

Neon Ne Simple Asphyxiant Nonflammable None

Nitric oxide NO 25 31 Nonflammable Slightly Irritating 100

Nitrogen N2 Simple Asphyxiant Nonflammable None

Nitrogen dioxide NO2 3.00 5.60 Nonflammable Irritating 20

Nitrogen trifluoride NF3 10 29 Nonflammable Mold-like 1000

Nitrous oxide N2O 50 90 Nonflammable Slightly Sweet

Oxygen O2 N/A N/A Nonflammable None

Phosphine PH3 0.30 0.42 1.6 98 Garlic-Like 50

Phosphorous pentafluoride PF5 None Established Nonflammable Irritating

Propane C3H8 2500 4510 2.1 9.5 Natural Gas-like 2100

Propylene CH2:CHCH3 Simple Asphyxiant 2.0 11.1 Slightly Sweet

Silane SiH4 5.00 6.60 1.4 96 Choking

Silicon tetrachloride SiCl4 None Established Nonflammable Pungent, Suffocating 100

Silicon tetrafluoride SiF4 None Established Nonflammable Suffocating

Sulfur dioxide SO2 2.00 5.20 Nonflammable Sharp, Pungent 100

Sulfur hexafluoride SF6 1000 5973 Nonflammable None

Trichlorosilane SiHCl3 None Established 7.0 83 Pungent, Suffocating 100

Trimethylamine (CH3)3N 5.00 12 2.0 11.6 Fish-like

Tungsten hexafluoride WF6 None Established Nonflammable None 30

Xenon Xe Simple Asphyxiant Nonflammable None

H
15
TECHNICAL DATA

CGA CONNECTIONS

Chemical High
Name Formula CGA Integrity

Acetylene C2H2 510

Air N/A 590

Ammonia NH3 240/705, 660 720

Argon Ar 580 718

Arsine AsH3 350 632

Boron trichloride BCl3 660 634

Boron trifluoride BF3 330 642

Butadiene, 1,3- CH2:CHCH:CH2 510

Butane, n- C4H10 510

Butene, 1- CH3CH2CH:CH2 510

Butene, 2- cis CH3CH:CHCH3 510

Butene, 2- trans CH3CH:CHCH3 510

Carbon dioxide CO2 320 716

Carbon monoxide CO 350 724

Chlorine Cl2 660 728

Deuterium D2 350

Diborane B2H6 350 632

Dichlorosilane SiH2Cl2 678 636

Dimethyl ether (CH3)2O 510

Dimethylamine (CH3)2NH 240/705

Disilane (SiH3)2 350 632

Ethane C2H6 350

Ethyl chloride CH3CH2Cl 300

Ethylene CH2:CH2 350

Ethylene oxide C2H4O 510

Halocarbon-14 CF4 320 716

Halocarbon-22 CHClF2 660

Halocarbon-23 CHF3 320 716

Halocarbon-116 C2F6 320 716

Halocarbon-134A CF3CH2F 660

Halocarbon-218 C3F8 660 716

Helium He 580 718

Hydrogen H2 350 724

*Typically offered/Available upon request.

H
16
TECHNICAL DATA

CGA CONNECTIONS

Chemical High
Name Formula CGA Integrity

Hydrogen bromide HBr 330 634

Hydrogen chloride HCl 330 634

Hydrogen fluoride HF 670 638

Hydrogen sulfide H2S 330 722

Isobutane CH(CH3)3 510

Isobutylene (CH3)2C:CH2 510

Krypton Kr 580 718

Methane CH4 350

Methyl bromide CH3Br 330

Methyl chloride CH3Cl 660

Monomethylamine CH3NH2 240/705

Natural gas N/A 350

Neon Ne 580 718

Nitric oxide NO 660

Nitrogen N2 580 718

Nitrogen dioxide NO2 660

Nitrogen trifluoride NF3 670, 330 640

Nitrous oxide N2O 326 712

Oxygen O2 540 714

Phosphine PH3 350 632

Phosphorous pentafluoride PF5 330, 660 642

Propane C3H8 510

Propylene CH2:CHCH3 510

Silane SiH4 350 632

Silicon tetrachloride SiCl4 330 636

Silicon tetraflouride SiF4 330 642

Sulfur dioxide SO2 660 634

Sulfur hexafluoride SF6 590 716

Trichlorosilane SiHCl3 678 636

Trimethylamine (CH3)3N 240/705

Tungsten hexafluoride WF6 670 638

Xenon Xe 580 718

*Typically offered/Available upon request.

H
17
TECHNICAL DATA

CGA CONNECTIONS

H
18
TECHNICAL DATA

ABBREVIATIONS & SYMBOLS

Symbol Definition Symbol Definition

A G
Å Angstrom(s) g gram(s)
AA Atomic Absorption gal gallon(s)
abs absolute GC Gas Chromatography or Chromatograph
ACGIH American Conference of GMIS Gas Manufacturers Intermediate Standard
Governmental Industrial Hygienists GPA Gas Processors Association
ASTM American Society for Testing Materials
atm atmosphere(s) H
avg average Hall Electrolytic Conductivity Detector
HAP Hazardous Air Pollutants
B HID Helium Ionization Detector
bp boiling point hr hour
Btu British thermal unit(s) Hz hertz

C I
CAA Clean Air Act ICP Inductively Coupled Plasma (Spectroscopy)
cal calorie(s) ID identification or inside diameter
CAS Chemical Abstract Services in,ins inch(es)
ccm cubic centimeter(s) per minute in3, cu in cubic inch(es)
ccs cubic centimeter(s) per second
CEM Continuous Emission Monitor J
cf cubic feet J joule
CFCs Chlorofluorocarbons
CFR Code of Federal Regulations K
CGA Compressed Gas Association K Kelvin
cm centimeter(s) kg kilogram(s)
cm2 square centimeter kPa Kilopascal(s)
o
cm3, cc cubic centimeter K degree(s) Kelvin
COA Certificate of Analysis
COC Certificate of Conformance L
CP Chemically Pure L liter(s)
Cp specific heat at constant pressure lb pound(s)
Cv specific heat at constant volume LC Liquid Chromatography
Cv coefficient of flow Lpm liters per minute
o
C degree(s) Celsius
M
D µ micron(s), 10–6 m
DID Discharge Ionization Detector m3 cubic meter(s)
DIN Deutsche Industrie Normen mA milliampere
(German Industrial Standards) max maximum
DISS Diameter Index Safety System mg milligram(s)
DOT Department of Transportation min minute(s)
ml milliliter(s)
E mm millimeter(s)
ea each MNPT Male National Pipe Thread
ECD Electron Capture Detector mol.wt. molecular weight
EPA Environmental Protection Agency MOS Metal Oxide Semiconductor
MPT Male Pipe Thread
F mp melting point
FID Flame Ionization Detector MS Mass Spectrometry
FNPT Female National Pipe Thread MSD Mass Selective Detector
F.O.B. Freight on Board MVCR Male VCR
FPD Flame Photometric Detector MVFS Male Vacuum Face Seal
FPT Female Pipe Thread MW molecular weight
ft foot, feet
ft3, cu ft cubic foot (feet) N
FTIR Fourier Transform Infrared Spectrometer or Spectroscopy N/A not applicable
FIFRA Federal Insecticide, Fungicide, nbp normal boiling point
o
and Rodenticide Act NDIR Non–Dispersive Infrared Analyzer
F degree(s) Fahrenheit NDUV Non–Dispersive Ultraviolet Analyzer
NER normal evaporation rate
NF National Formulary
NFPA National Fire Protection Association H
19
TECHNICAL DATA

ABBREVIATIONS & SYMBOLS

Symbol Definition Symbol Definition

NIST National Institute of Standards and S


Technology scc standard cubic centimeters
nm nanometer(s) sccm standard cubic centimeters per minute
No number sccs standard cubic centimeters per second
nom nominal scfh standard cubic feet per hour
NOS not otherwise specified scfm standard cubic feet per minute
NPD Nitrogen/Phosphorous Detector scfs standard cubic feet per second
NPT National Pipe Thread sec second(s)
NTP Normal temperature and pressure SFC Supercritical Fluid Chromatography
NTRM NIST Traceable Reference Material SFE Supercritical Fluid Extraction
NMR Nuclear Magnetic Resonance slpm standard liters per minute
Spectroscopy sp. gr. specific gravity
sp. vol. specific volume
O SRM Standard Reference Materials
OD outside diameter SS Stainless Steel
Ohm–cm ohms centimeter Stn. Stl. Stainless Steel
OSHA Occupational Safety and STEL Short Term Exposure Limit
Health Administration STP standard temperature and pressure
oz ounce(s)
T
P TCD Thermal Conductivity Detector
Pa pascal(s) TEA Transversely Excited Atmosphere
PID Photo Ionization Detector THC Total Hydrocarbon Content
ppb part(s) per billion TLV Threshold Limit Value
ppba part(s) per billion atomic tp triple point
ppbv part(s) per billion by volume TPH Total Petroleum Hydrocarbons
ppbw part(s) per billion by weight TWA Time Weighted Average
ppm part(s) per million
ppma part(s) per million atomic U
ppmv part(s) per million by volume UHP Ultra High Purity
ppmw part(s) per million by weight UN United Nations
ppt part(s) per trillion USP United States Pharmacopoeia
ppta part(s) per trillion atomic
pptv part(s) per trillion by volume V
pptw part(s) per trillion by weight VAC volts alternating current
psi pound(s)–force per square inch VDC volts direct current
psia pound(s)–force per square inch VOC Volatile Organic Compounds
absolute vol volume
psig pound(s)–force per square inch vol% volume percent
gauge
W
R w.c. water column pressure
Ra Roughness average wt. weight
RFO restricted flow orifice wt% weight percent
oR degree(s) Rankine wt. ppm weight parts per million

Y
yd yard(s)

> greater than


< less than

H
20
TECHNICAL DATA

GLOSSARY

ABSOLUTE PRESSURE - A quantity of pressure BALANCED POPPET (BALANCED VALVE; BAL- CATALYST - A substance that initiates a chemical reac-
measured with respect to total vacuum. Equal to the ANCED STEM) - A valve which has been tion and allows it to proceed under different conditions
sum of a pressure gauge reading and atmospheric designed to be pressure balanced; hence the valve than otherwise possible.
pressure. spring provides the shutoff force. Used essentially
to reduce or minimize decaying inlet pressure CGA NUMBER - Cylinder/container valve outlet
ABSOLUTE ZERO - The minimum point in thermo- effect. connection number assigned by the Compressed
dynamic temperature scale Gas Association. CGA numbers are detailed in
(-273.1 6oC or -459.69oF) BOILING POINT - The temperature at which the CGA Standard V-1.
vapor pressure of the liquid is equal to the prevail-
ABSORPTION - The penetration of matter in bulk ing pressure of the atmosphere. The normal boiling CHEMICAL ABSTRACT SERVICES (CAS) - CAS numbers
into other matter, as in the dissolving of a gas in point is the temperature at which the vapor pres- represent chemical substances recorded in the CAS
liquid. sure of the liquid is 14.7 psia (1 atm). Chemical Registry System. This numbering system identifies
chemical substances by an unambiguous computer lan-
ACCURACY - The degree of agreement of a measured BONNET (SPRING HOUSING) - The part of a guage description of its molecular structure, including all
value with the true or expected value of the quantity of regulator which houses the control spring. stereo-chemical detail. The CAS number, which has no
concern. chemical significance, is simply a number assigned in
BOURDON TUBE - A curved metal tube, sealed sequential order to each substance as it enters the Registry
ADSORPTION -Adherence of the atoms, ions or mole- at one end, which flexes to a known degree when System. All specific substances reported in the worldís scien-
cules of a gas or liquid to the surface of another sub- pressurized internally. tific and technical literature and indexed in Chemical
stance, called the adsorbent. Molecular Sieves are Abstracts, (CA) since 1965 (when the Registry System
adsorbents. BRASS - Brass - copper/zinc alloys of varying composi- began) are included in this master file.
tion. Some brass also contains low percentages of other
AMERICAN CONFERENCE OF GOVERNMENTAL elements such as manganese, aluminum, silicon, lead CHEMILUMINESCENCE - A species which chemi-
INDUSTRIAL HYGIENISTS (ACGIH) - This and tin. cally absorbs and emits light (usually at low tem-
Conference is a professional society, not an official peratures).
Government Agency. It is an organization devoted to BRITISH THERMAL UNIT (BTU) - The quantity of heat
CHROMATOGRAM - The record produced by the gas liq-
the development of administrative and technical aspects required to raise the temperature of one pound of water
uid chromatograph. It is also a measure of instrument per-
of worker protection. one degree F at or near its point of maximum density
formance.
(39.1oF).
ANHYDROUS - A descriptive term meaning without
COEFFICIENT OF FLOW (Cv) - Defined as the
water. BURSTING DISK (FRANGIBLE DISK) - A
actual flow performance in U.S. gallons of water per
metal disk which is part of a safety device, and
minute at 60oF when inlet pressure (P1) is 1 psig and
ANNEALING GAS - A hydrogen and nitrogen which is intended to burst and allow gas to escape
outlet pressure (P2) is atmospheric (14.7 psia).
mixture used to provide a reducing atmosphere within predetermined pressure limits to prevent rup-
during heating of metals to render them less brittle ture of the device it is installed on. Similar in func-
COLUMN - Part of the gas chromatography system
on cooling. tion to a safety relief valve, except it has no reseal
where the separation of the sample takes place (can
capability.
be packed or capillary).
ASPHYXIANT GAS - A gas which has little or no
positive toxic effect but which can bring about BURST PRESSURE - A design test pressure which allows COMBUSTION - An exothermic oxidation reaction which
unconsciousness and death by replacing air and for permanent deformation and leakage, but parts must may occur with any organic compound, as well as with cer-
thus depriving an organism of oxygen. remain assembled (i.e., no sudden ruptures). Normal indus- tain elements.
try standard is 4 times (400%) of maximum operating pres-
ATTACHED POPPET (TIED-SEAT; TIED- sure. See also “PROOF PRESSURE” and “MAXIMUM COMPRESSED GAS - (1) A gas or mixture of gases hav-
DIAPHRAGM) - A feature of certain regulators OPERATING PRESSURE.” ing, in a container, an absolute pressure exceeding 40 psi
whereby the stem (poppet) is physically attached to the at 70oF; or (2) a gas or mixture of gases having, in a con-
diaphragm. CALIBRATION - Comparison of a measurement stan- tainer, an absolute pressure exceeding 104 psi at 130oF
dard or instrument with another standard or instrument regardless of the pressure at 70oF or (3) a liquid flamma-
ATOMIC WEIGHT - The relative weight of an to report or eliminate by adjustment any variation (devi- ble material having a vapor pressure exceeding 40 psi at
atom of an element, compared to carbon-12. ation) in the accuracy of the item being compared. 100oF as determined by ASTM D-323-72.
Equivalent to the sum of protons and neutrons in
the nucleus. CALIBRATION GAS - A gas or gas mixture of COMPRESSED GAS ASSOCIATION (CGA) - This is
accurately known composition used as a compara- a nonprofit technical association whose membership
AZEOTROPIC MIXTURE (AZEOTROPE) - tive standard in analytical instrumentation. includes many corporations active in all phases of the
A liquid mixture of two or more substances which compressed gas industries. Founded in 1913, the CGA
behaves like a single substance in that the vapor CALORIE - The amount of heat required to raise uses experience and knowledge of its members to pro-
produced by partial evaporation of liquid has the the temperature of one gram of water one degree mote industry wide standards and procedures for safety
same composition as the liquid. The constant boiling Celsius. in the manufacture, storage, transport and use of
mixture exhibits either a maximum or minimum boil- compressed gases.
ing point as compared with that of other mixtures of CARRIER GAS - Gas used with a gas chromatogra-
the same substances. phy to carry the sample through the system.

BACK PRESSURE REGULATOR - A pressure reg-


ulator which controls upstream (inlet) pressure.
Similar in function to a relief valve.

H
21
TECHNICAL DATA

GLOSSARY

CORROSIVE - The ability of a chemical com- DEPARTMENT OF TRANSPORTATION (DOT) - ■ “Delayed (Chronic) Health Hazard” including
pound to attack and produce irreversible damage This is a government agency whose Title 49, Code of carcinogens and other hazardous chemicals
to human tissues, such as eyes, skin or mucous Federal Regulations regulates the transport of haz- which cause an adverse effect to a target
membranes. Also, the ability of a chemical com- ardous materials. organ which manifests itself after a long peri-
pound to attack and eat away rubber, metal and od of time following or during repeated con-
other substances. DEWAR - Vessel which contains cryogenic liquefied tacts with the substance.
gases. ■ “Fire Hazard” including flammable, com-
CRACKING PRESSURE - A term used in back pressure bustible pyrophoric, and oxidizer.
control only (e.g., back pressure regulators, relief valves), DEW POINT - The temperature at which the ■ “Sudden Release of Pressure Hazard includ-
for determining the inlet pressure at which flow starts. liquefaction of vapor begins; the term is usually ing explosive and compressed gas.
applied to condensation of moisture from the water ■ “Reactive Hazard” including unstable reactive,
CREEP - Any increase in outlet pressure of a pres- vapor in the atmosphere. organic peroxide, and water reactive.
sure regulator subsequent to lockup. Usually seen
as a long term slow pressure increase. This gener- DIAMETER INDEX SAFETY SYSTEM (DISS) - DISS EXPOSURE LIMITS - Concentrations of substances
ally indicates a seat leak which is an abnormal outlet valves are generally used with high-purity prod- (and conditions) under which it is believed that
condition. ucts, toxics, and corrosives. Valves equipped with DISS nearly all workers may be repeatedly exposed day
outlet assignment provide a metal-to-metal seal that cre- after day without adverse effects. ACGIH limits are
CRITICAL DENSITY - The density of a pure materi- ates low particle generation, a permeation-free environ- called TLV and OSHA exposure limits are called
al at its critical temperature and critical pressure. ment, and good leak integrity. PEL. See “THRESHOLD LIMIT VALUE.”

CRITICAL POINT - The transition point at which DOPANT - An impurity usually added in small FILLING DENSITY - The percent ratio of the weight
the liquid and gaseous states of a substance merge amounts to a pure substance to alter its properties. of gas in a container to the weight of water that the
into each other. It is the temperature above which container will hold at 60oF.
a substance cannot exist in two phases, no matter DOT ID NUMBERS - These are product identi-
how great the pressure. See also “CRITICAL fication numbers, assigned by the Department of FIRE HAZARD - See “EPA HAZARD
TEMPERATURE” and “CRITICAL PRESSURE.” Transportation (DOT) to assist members of fire and CATEGORIES.”
police departments in using the DOT Emergency
CRITICAL PRESSURE - At the critical temperature, Response Guidebook. DOT ID numbers contain FLAMMABLE GAS - (1) A gas that, at ambient temper-
the highest pressure at which a pure material can two letters followed by four digits. The prefix UN ature and pressure, forms a flammable mixture with air
exist as a gas in equilibrium with its liquid. (for United Nations) identifies products recognized at a concentration of 13% by volume or less; or (2) a
throughout the world. Gaseous nitrogen, for exam- gas that, at ambient temperature and pressure, forms a
CRITICAL TEMPERATURE - The temperature above ple, is identified as UN 1066. range of flammable mixtures with air wider than 12% by
which a gas cannot be liquefied by pressure alone. At volume regardless of the lower limit.
this temperature, there is no distinction between liquid DROOP - The decrease in outlet set pressure of a
and vapor, both having the same density and consti- pressure regulator which results from an increase in FLAMMABLE LIMITS - The concentration of flammable
tuting one homogenous system. flow rate. Essentially the reverse of lockup. See also vapor in air, oxygen, or other oxidant that will propa-
“LOCKUP.” gate flame upon contact when provided with a source of
CRYOGENIC LIQUID - A liquid having a normal boil- ignition. The lower explosive limit (LEL) is the concentra-
ing point below -240oF (-151.11oC). EDUCTOR (LIQUID DELIVERY) TUBE - A tube tion below which a flame will not propagate; the upper
inside a cylinder or container attached to the cylinder explosive limit (UEL) is the concentration above which a
CRYOGENIC LIQUID CONTAINER - An insulat- valve which allows liquid product withdrawal from the flame will not propagate. A change in temperature or
ed container designed to store, handle and trans- cylinder. pressure may vary the flammable limits.
port liquids having boiling points below –130oF.
EFFLUENT SPLITTER - The part of the analytical instru- FLAMMABLE RANGE - The range over which a
CYLINDER - A container designed to hold compressed ment that splits the effluent stream into multiple detectors gas at NTP will form a flammable mixture with air.
gases or liquefied compressed gases. Cylinders are man- or some to vent for a lower volume of effluent.
ufactured and tested according to DOT/CTC/MEX speci- FLASH POINT - The lowest temperature at which a
fications. ENVIRONMENTAL PROTECTION AGENCY flammable liquid will give off enough vapor at or near
(EPA) - This is a government agency that establishes its surface to form an ignitable mixture with air.
DEHYDRATION - Removal of one or more molecules environmental standards within the United States.
of water from a chemical compound. FLOW CAPACITY - The maximum flow capability of a
EPA HAZARD CATEGORIES - The hazard cate- control device established at a specific set of conditions.
DELAYED (CHRONIC) HEALTH HAZARD - See “EPA gories used throughout this catalog as defined
HAZARD CATEGORIES.” under EPA SARA Title III and 1910.1200 of Title FLUID - Any material or substance that changes shape
29 of the Code of Federal Regulations are as fol- uniformly in response to an external force imposed
DELIVERY PRESSURE - See “OUTLET PRESSURE.” lows: upon it. The term applies to liquids, gases and finely
divided solids.
DENSITY - The ratio of the amount of anything per unit ■ “Immediate (Acute) Health Hazard” including
volume; e.g., mass of any substance per unit volume at highly toxic, corrosive, toxic, irritant, sensitiz- FREEZING POINT - The temperature at which a
any definite temperature. It is usually expressed in er, and other hazardous chemicals which liquid solidifies. It is the temperature at which the
pounds per cubic foot (lbs/ft3). See also “SPECIFIC cause an adverse effect to a target organ liquid and solid states of a substance are in equilib-
GRAVITY.” which manifests itself within a short period of rium at a given pressure (usually atmospheric). For
time following a one-time, high exposure to pure substances, it is identical with the melting point
the substance. of the solid form.

H
22
TECHNICAL DATA

GLOSSARY

GROSS WEIGHT - The weight of a package plus LIQUID DENSITY - The ratio of the mass of a liquid per NORMAL TEMPERATURE AND PRESSURE
the weight of its contents. unit volume at any definite temperature. It is usually (NTP) - A gas industry reference base. Normal temperature is
expressed in pounds per gallon or pounds per cubic foot. 70oF. Normal pressure is one atmosphere or 14,696 psia.
HALOCARBONS - Any hydrocarbon combined
with any of the five (F2, Cl2, Br, I, At) elements in LOCKUP - The increase in outlet pressure of OCCUPATIONAL SAFETY AND HEALTH
the V11A group of the periodic table. a pressure regulator that occurs when flow is ADMINISTRATION (OSHA) - An organization
stopped. Essentially the reverse of droop. within the U.S. Department of Labor which sets
HEAT OF ADSORPTION - The total heat involved standards for employers to ensure safe and health-
in the adsorption process from zero adsorbate loading LOWER EXPLOSIVE LIMIT (LEL) - The minimum ful working conditions for employees.
to some final adsorbate loading at a constant temper- percent by volume of a gas which, when mixed with
ature (also called isothermal integral heat of air at normal temperature and pressure, will form a OUTLET PRESSURE (P2; DELIVERY PRESSURE;
adsorption). flammable mixture. See “FLAMMABLE GAS.” DOWNSTREAM PRESSURE) - The pressure of the
fluid from the discharge connection of a control device.
HEAT OF FUSION - The heat energy required to MANIFOLD - A series of connectors to a common
transform one mole of substance from the liquid outlet allowing several cylinders to be used OXIDIZER - A chemical reagent which causes oxi-
phase to the vapor phase at one atmosphere of simultaneously. dation of other substances and is thereby reduced.
pressure.
MATERIAL SAFETY DATA SHEET (MSDS) - PARTIAL PRESSURE - In any gas mixture the total
HEAT OF VAPORIZATION - Heat required to An MSDS is a substance fact sheet containing charac- pressure is equal to the sum of the pressures (par-
convert a substance from the liquid to the gaseous teristics and hazards of specific hazardous industrial tial) which each gas would exert were it alone in
state with no temperature change. material. Also, these data sheets provide precautionary the volume occupied by the mixture.
information on safe handling of the material as well as
HYDROCARBON - An organic compound emergency and first aid procedures. PARTS PER MILLION (PPM) - A convenient means
containing carbon and hydrogen. for expressing low concentrations. As applied to
MAXIMUM OPERATING PRESSURE - The maxi- gases, PPM stands for moles per million moles. PPM
IMMEDIATE (ACUTE) HEALTH HAZARD - mum allowable use pressure for which a system is by weight is expressed as pounds per million pounds.
See “EPA HAZARD CATEGORIES.” designed. Also referred to as “working pressure.” PPM by volume is usually expressed in cubic feet per
million cubic feet.
INERT - A material which, under normal temper- MELTING POINT - The temperature at which the
atures and pressures, does not react with other solid and liquid phase of a substance are in equi- PERMISSIBLE EXPOSURE LIMITS (PEL) -
materials. librium (normally specified at one atm). See “EXPOSURE LIMIT.”

INHIBITOR - A compound (usually organic) that MICRON - One millionth of a meter. PHYSICAL HAZARD - Descriptive of a chemical for
retards or stops an undesired chemical reaction which there is scientifically valid evidence that it is a
such as corrosion, oxidation or polymerization. MIXTURE - Any combination of two or more combustible liquid, a compressed gas, explosive,
chemicals if the combination is not, in whole or in flammable, an organic peroxide, an oxidizer,
INLET PRESSURE (P1; SUPPLY PRESSURE; part, the result of a chemical reaction. pyrophoric, unstable reactive or water reactive.
UPSTREAM PRESSURE) - The pressure of the
fluid to the supply connection of a control device. MOLE - The weight of a substance equal numer- POISON - A substance that in relatively small
ically to its molecular weight. A gram-mole is the doses has an action, when it is ingested by, injected
INORGANIC SUBSTANCE - Substances that do weight in grams equal to the molecular weight; a into, inhaled or absorbed by, or applied to a living
not contain carbon in their chemical structure. pound-mole is the weight in pounds equal to the organism, that either destroys life or impairs serious-
molecular weight. ly the function of one or more organs or tissues.
IRRITANT - The ability of a chemical, which is not
corrosive, to cause a reversible inflammatory effect MOLECULAR WEIGHT - The sum of the atomic POLYMERIZATION - A chemical reaction, usually
on living tissue by chemical action at the site of weights of all the constituent atoms in the molecule carried out with a catalyst, heat or light, and often
contact. of an element or a compound. under high pressure, in which a large number of rela-
tively simple molecules combine to form a chain-like
ISOTOPES - Forms of an element that differ from one NANOGRAM (ng) - One billionth of a gram (10-9). macromolecule.
another in the mass of their atoms and in the properties
dependent on that mass. Having the same atomic number NANOMETER (nm) - One billionth of a meter (10-9). PROOF PRESSURE - A test pressure applied to
and the same number of valence electrons, isotopes occu- control devices to verify structural integrity. No
py the same position in the periodic table and have iden- NATIONAL FORMULARY (NF) - A supplement to deformation or excessive leakage is permitted at
tical properties. They are distinguishable only by the small the United States Pharmacopoeia. this pressure and the control device must function
differences in atomic weight or by radioactive transforma- normally subsequent to this test. Normal industry
tions. NORMAL BOILING POINT (nbp) - The temper- standard is 1.5 times (150%) of working pressure.
ature at which the vapor pressure of a liquid See also “BURST PRESSURE” and “MAXIMUM
KELVIN (K) - A unit of temperature related to the reaches 760 mm of mercury. OPERATING PRESSURE.”
triple point of water.
NORMAL EVAPORATION RATE (NER) -
LIQUEFIED COMPRESSED GAS - A gas which, The degree of product loss from a cryogenic liquid
under the charged pressure, is partially liquid at a container due to heat leak into the container as
temperature of 70oF (21.1oC). designed. The NER is checked by measuring the
amount of product loss over a specified time and
serves to confirm whether the insulation is still
good or not. H
23
TECHNICAL DATA

GLOSSARY

PYROPHORIC - The ability of a chemical to ignite SPECIFIC GRAVITY (Sp. Gr.) - The ratio of the THRESHOLD LIMIT VALUE - TIME WEIGHTED
spontaneously in air at a temperature of 130OF or weight of one substance compared to the weight AVERAGE (TLV-TWA) - Refers to the time-weighted
below. of an equal volume of another substance which is average concentration for a normal 8 hour work-
used as a standard. Usually gases are compared day and a 40 hour workweek to which nearly all
PYROPHORIC GAS - A gas that can spontaneously to air (air =1) while liquids and solids are com- workers may be repeatedly exposed, day after
self-ignite when exposed to normal atmospheric pared to water (H2O = 1). day, without adverse effect.
conditions.
SPECIFIC HEAT - Amount of heat required to TIED-DIAPHRAGM - See “ATTACHED POPPET.”
RARE GAS - Refers to those constituents of air which raise a unit mass of a substance one degree of
comprise less than 1% of air and are generally con- temperature at either constant pressure (Cp) or TIED-SEAT - See “ATTACHED POPPET.”
sidered inert such as argon, helium, krypton, neon constant volume (Cv).
and xenon. TOTAL HYDROCARBON CONTENT (THC) -
SPECIFIC HEAT RATIO - The ratio of specific THC is used to describe the quantity of the hydro-
REACTIVE HAZARD - See “EPA HAZARD.” heat at constant pressure (Cp) to the specific heat carbon impurities present. Usually expressed as
at constant volume (Cv). methane equivalents.
RELIEF VALVE - A type of pressure relief device
which is designed to relieve excessive pressure, and SPECIFIC VOLUME (Sp. Vol.) - Volume occupied by TOXIC - A substance that has the ability to
to reclose and reseal to prevent further flow of gas a unit mass of a substance at a given temperature. It is produce injurious or lethal effects through its
from the cylinder after reseating pressure has been usually expressed in cubic feet per pound or gallons per chemical interaction with the body.
achieved. pound.
TRIPLE POINT (tp) - The definite temperature
SPRING HOUSING - See “BONNET.” and pressure for a pure substance at which the
RESTRICTIVE FLOW ORIFICE (RFO) - A safety three phases (solid, liquid and vapor) coexist in
device place in the outlet of a cylinder valve that is STAINLESS STEEL - Alloy steels containing high equilibrium as an invariant system.
intended to limit the release rate of a hazardous percentages of chromium, from less than 10% to
gas to a maximum specified range in the event of more than 25%. UNITED NATIONS (UN) - See “DOT” ID
the inadvertent opening of the valve or failure of NUMBERS.
the system downstream of the valve outlet. STANDARD TEMPERATURE AND PRESSURE
(STP) - An internationally accepted reference base. UNITED STATES PHARMACOPOEIA (USP) -
SAFETY RELIEF DEVICE - A safety device usually Standard temperature is OOC. Standard pressure is The official publication for drug product standards.
incorporated in a cylinder valve and actuated by one atmosphere or 14.6960 psia.
excessive pressure or temperature, or both, at prede- UNSTABLE REACTIVE - The ability of a chemical
termined limits to avoid failure of the pressure vessel. SUBLIMATION - The direct passage of a sub- in the pure state, or as produced or transported, to
stance from solid to vapor without appearing in vigorously polymerize, decompose, condense, or
SELF-RELIEVING (SELF-VENTING) - A feature the intermediate (liquid) state. An example is solid become self-reactive under conditions of shock,
incorporated in certain pressure reducing regula- carbon dioxide (dry ice) which vaporizes at room pressure or temperature.
tors which enables the unit to relieve the outlet temperature.
pressure when adjusted in the decrease direction. UPSTREAM PRESSURE - See “INLET PRESSURE.”
SUDDEN RELEASE OF PRESSURE HAZARD -
SENSITIZER - The ability of a chemical to cause See “EPA HAZARD CATEGORIES.” VAPOR PRESSURE - The pressure characteristic at
a substantial proportion of exposed people or any given temperature of a vapor in equilibrium with
animals to develop an allergic reaction in normal TARE WEIGHT - The weight of an empty cylinder its liquid or solid form.
tissue after repeated exposure to the chemical. without cap and valve.
WATER REACTIVE - The ability of a chemical
SHORT TERM EXPOSURE LIMIT (STEL) - THRESHOLD LIMIT VALUE (TLV) - TLV’s are to react with water to release a gas that is either
See “THRESHOLD LIMIT VALUE - SHORT TERM measures of toxicity established by ACGIH. The flammable or presents a health hazard.
EXPOSURE LIMIT.” TLV of a substance refers, in general, to airborne
concentrations at or below which nearly all work- WORKING PRESSURE - See “MAXIMUM
SKIN - The “SKIN” designation, used with the ers may be repeatedly exposed without adverse OPERATING PRESSURE.”
terms TLV-TWA and OSHA-PEL, indicates that effect.
cutaneous absorption may contribute to the ZERO GAS - Gases which are used as a
overall exposure. THRESHOLD LIMIT VALUE - CEILING (TLV- reference point to “zero” an analyzer.
CEILING) - Refers to an airborne concentration
SOLVENT - A substance capable of dissolving that should not be exceeded even instantaneously.
another substance (solute) to form a uniformly dis-
persed mixture (solution) at the molecular or ionic THRESHOLD LIMIT VALUE - SHORT TERM
size level. EXPOSURE LIMIT (TLV-STEL) - Refers to a 15
minute time-weighted average exposure which
SPAN GAS - Gases which are used as a refer- should not be exceeded at any time during a work-
ence point to span an analyzer. day even if the time-weighted average is within the
TLV. It supplements the 8 hour TLV-TWA for certain
substances that produce acute effects on high,
short term exposure.