0% found this document useful (0 votes)
30 views1 page

Section X-X: See Truss Detail

The document contains architectural drawings and specifications for a proposed 2-storey commercial and residential building. It includes details such as dimensions, door and window schedules, and sections of the building. Additionally, it emphasizes the protection of intellectual property rights related to the architectural designs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views1 page

Section X-X: See Truss Detail

The document contains architectural drawings and specifications for a proposed 2-storey commercial and residential building. It includes details such as dimensions, door and window schedules, and sections of the building. Additionally, it emphasizes the protection of intellectual property rights related to the architectural designs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ROOF APEX

1100
SEE TRUSS DETAIL
TOP OF ROOF BEAM
3000

2450
900
800 600

300
7800

SECOND FLOOR LINE

1200

2100

2100

2100
KITCHEN
3200

900
FINISH FLOOR LINE FINISH FLOOR LINE
D-1 D-2 D-3 D-4
500

NATURAL GROUND LINE


GI ROLL-UP DOOR SOLID PANEL TYPE DOOR SOLID PANEL TYPE DOOR PVC DOOR
1 SET 2 SETS 2 SETS 2 SETS
SECTION X-X
SCALE 1 : 100 MTS.

2450 1200 1800


1200
500

300
ROLL-UP DOOR

600

600
1200

1200

1200
ROOF APEX
1100

SEE TRUSS DETAIL

1500

1500
TRB

900

900

900
FINISH FLOOR LINE
W-1 W-2 W-3 W-4 W-5
3000

BEDROOM ANALOK TYPE SLIDING ANALOK TYPE SLIDING ANALOK TYPE SLIDING ANALOK TYPE SLIDING ANALOK TYPE SLIDING
WINDOW W/ ROLL-UP DOOR WINDOW W/ CANOPY WINDOW W/ CANOPY WINDOW W/ CANOPY WINDOW W/ CANOPY
1 SET 5 SETS 3 SETS 1 SET 2 SETS
7800

SFL

WATER
KITCHEN SCHEDULE OF DOORS & WINDOWS
3200

SCALE 1 : 100 MTS.


STATION

FFL
500

NGL

SECTION Y-Y
SCALE 1 : 100 MTS.

CIVIL ENGINEER: DESIGNED BY: REVISIONS: DATE: PROJECT TITLE: OWNER : R.A. 9266 Article 3 Section 20 SHEET CONTENTS: SHEET NO:
engr. rcm Drawings and specifications duly signed, stamped or sealed as instruments of service
CADD BY:
PROPOSED 2-STOREY COMMERCIAL/ are the properties and documents of the architect whether the object for which they are made
is executed or not. It shall be unlawful for any person, without the written consent of the
RESIDENTIAL BUILDING
RITCHIE C. MALASAN
CHECKED BY:
engr. rcm

PROJECT LOCATION: ADDRESS:


architect or author of said documents to duplicate or to make copies of said documents for use
in the repitition of and for other projects or building, whether executed partly or in whole.
AS SHOWN
A-3
PRC REG NO.:

VALIDITY:
PTR NO.:

DATE ISSUED: DATE: DATE APPROVED:


PRESIDENTIAL DECREE NO. 49
"Protection of Intellectual Property" November 14, 1972
Works of art, architecture, models and designs are creative work and considered
3 9
TIN: PLACE ISSUED: considered as part of the inllectual property of the author duly protected under P.D. 49.

You might also like