Electric Actuators and Actuator Controls: Measurements in Imperial and Metric Units
Electric Actuators and Actuator Controls: Measurements in Imperial and Metric Units
Electric Actuators
and Actuator Controls
Measurements in Imperial and Metric Units
Warner Linear is dedicated to designing and manufacturing the
broadest selection of rugged service electromechanical actuators
that serve the…
light-duty, general-duty,
or rugged-duty applications.
All are engineered for maintenance-free, long-life service, providing maximum value for our customers.
Our electric actuators are engineered and produced using quality components from ISO registered key
suppliers.
Warner Linear provides a full line of actuator controls well suited for a broad range of application needs.
They range from simple to use switch box controls for basic extend/retract function, to state-of-the-art
microprocessor based digital electronic controls using SMT design and manufacturing processes.
Controls – Input Voltage (vdc): Input Voltage (vdc): Input Voltage (vdc):
BTc P2-DC...........................68 12, 24 12, 24 12, 24
Stand. Stroke Length in. (mm) Stand. Stroke Length in. (mm) Stand. Stroke Length in. (mm) Stand. Stroke Length in. (mm) Stand. Stroke Length in. (mm)
2 to 12 in 2” increments 2 to 24 in 2” increments 2 to 24 in 2” increments 4 to 24 in 2” increments 4 to 24 in 2” increments
(50 to 300 in 50 mm (50 to 600 in 50 mm (50 to 600 in 50 mm (100 to 600 in 50 mm (100 to 600 in 50 mm
increments) increments) increments) increments) increments)
Input Voltage (vdc): Input Voltage (vdc): Input Voltage (vdc): Input Voltage (vac): Input Voltage (vac):
12, 24 12, 24, 36, 48, 90 12, 24, 36, 48, 90 115, 230 115, 230
Typical Applications: Typical Applications: Typical Applications: Typical Applications: Typical Applications:
• Fertilizer Gate Control • Residential Mower Decks • Paving Outriggers • Engine Lifts • Indoor Applications
• Mower Decks • Gate & Valve Operation • Commercial Mower Decks • Tables • Machine Tools
• Gate Openers • Snow Blowers • Spray Booms • Indoor Applications • HVAC
• Scooter & Cycle Lifts • Spouts & Chutes • ATV Dump Box Lifts • Machine Tools • Hood Lifts
• Pull Behind Implement Lifts • Engine Lifts • Boat Engine Lifts • Egg Rotation • Tables
• Tables • Hydraulic Cylinder
• Wagon Lifts Replacement
• Combine Concaves • Construction Equipment
Pg 24-27 Pg 28-31 Pg 36-39 Pg 32-35 Pg 40-43
Applications and Performance Features
Dependable Operation
Compact design
A Warner Linear actuator with a two inch stroke can provide
up to 2800 pounds (12455 N) of force capacity in a compact
package.
Maintenance-free
Units are lubricated for life during assembly. There are no adjustments or maintenance
required for units after they have left the factory. Consistent performance is provided for
the entire life of the actuator.
Efficient operation
Warner Linear actuators consist of an electric motor combined with a high efficiency
gear train and lead screw. This direct conversion of electrical to mechanical energy
results in effective, economic linear movement. Units are completely self-contained and
require minimal installation hardware or wiring.
Advantages
• No hydraulic pumps, hoses, valves, or leaks
• Holds load when power is off
• Overload clutches prevent damage due to excess weight
• Simple to install and use
• Easily adaptable for position
control
• Integrated sensors provide
electrical position signals
Key Features
• Compact size
Integral end of stroke
• Efficient design
limit switches standard.
• Easy to use and install Thermal overloads in windings
No clutch required.
protect the motor
Standard Models
M1
Lightweight aluminum
extension rod
How To Select
Step 1 – Determine Load and Stroke length requirements Important Unit Restrictions
Use the Quick Selection guide to identify the model that will
Side loading and shock loads must be considered in actuator
provide the load capacity and stroke length needed for your
applications. Side loading and cantilevered mounting should
application.
be eliminated through proper machine design. Side loading
Step 2 – Identify motor type and voltage will dramatically reduce unit life. While actuators can withstand
Select DC motor and motor voltage. limited shock loads, it is recommended that shock loading be
avoided wherever possible. (See General Mounting Information
Step 3 – Confirm Speed and Current draw requirements on page 71)
Using the charts provided, confirm that unit speed and current
draw is appropriate for the intended use. Step 5 – Unit Options
M-Track units include end-of-travel limit switches as a standard
Step 4 – Confirm the application Duty Cycle feature. For positional feedback, a 12K linear membrane
At full load capacity, actuators have a 25% duty cycle. potentiometer can be factory installed. The changing
potentiometer value provides unit movement feedback for units
on-time
Duty cycle is the amount of that are not visible to the machine operator.
on-time + off-time
A unit that runs for 15 seconds should be off for 45 seconds.
M-Track Configurator
M1 – D012 – 0050 – A 02 – L P
Note: Not all load ratings are Note: Not all stroke lengths are
standard for all units. standard on all units. Consult
Consult unit page for details. unit page for details.
Scan to watch!
Linear Actuator Basic Selection Video
https://p.widencdn.net/ydtpk6
Specifications
Specifications
Load Capacity 25 lbs. (111 N) 50 lbs. (222 N) 100 lbs. (445 N) 165 lbs. (734 N)
Speed at Full Load 1.75 in. (45 mm)/sec 0.80 in. (20 mm)/sec 0.45 in. (11 mm)/sec 0.25 in. (6 mm)/sec
Input Voltage 12 or 24 volt DC for all models
Static Load Capacity 300 lbs. (135 N) for all models
Stroke Length 1, 2, 4, 6, 8, 10 and 12 in. (50, 100, 150, 200, 254, 300 mm) for all models
Clevis Ends .25 in. (6.4 mm) diameter
Duty Cycle 25% for all models
Operation Temperature Range -20º F to +150º F (-26º to + 65º C) for all models, -40º F to +185º F (-40º C to +80º C) available
Environment IP65 Dynamic, IP69K and Temporary Immersion with Protective Boot
Limit Switch Fixed end of stroke limit switches standard for all units
Potentiometer Linear membrane potentiometer optional on all units
Dimensions
in. mm in. mm in. mm in. mm in. mm in. mm
7 Stroke 6 2 50 5 4 100 6 4 150 8 200
3 10 254 2 12 300 1
M-Track A (w/o POT) 6.22 158.0 8.23 209.0 10.24 260.1 12.24 310.9 14.25 362.0 16.26 413.0
A (POT) 7.55 191.8 9.57 243.1 11.57 293.9 13.58 344.9 15.58 395.7 17.58 446.5
Note: Special lengths available; metric stroke length for reference only
["A"]
"A" RETRACTED
[ 355
304 ]
STROKE TOLERANCE
IS +/-.078 [1.98]
14.0 [ 7.7 ]
[ 38.2 ] 12.0 .30 [ 8.3 ]
1.50 .33
[ 9.1 ]
[ 19.1 ] [
19.94 - 00.051 ] .36
[ 33 ]
1.30 [ 16.4 ]
.75
Ø .785 +.000
- .002 .65
[ 73.3 ]
2.89 [ 52.1 ]
[ 38.10 ]
2.05
[ 6.58
6.43 ] [ 6.579
6.426 ]
Ø 1.500
Ø .259
.253
THRU 2X Ø .259 THRU
[ 29.5 ] [ 9.5 ] .253
1.16 DELPHI PACKARD MALE CONNECTOR .38
8911773 BODY [ 37.4 ]
6294511 TERMINALS (2) [ 106.2 ]
1.47 4.18
CONNECT (+) TO & (-) TO BLACK
ALL DIMENSIONS ARE NOMINAL TO EXTEND ACTUATOR
UNLESS OTHERWISE SPECIFIED
NO CONNECTOR ON POTENTIOMETER UNIT
Measurements in inches, metric in brackets.
• Stroke and its tolerance are based on a unit with no • Mounting points in the applicationCREATEDTuesday, must allow the
June 26, 2007 8:32:43actuator
AM
attached load operating at rated voltage +/-.5VDC, 70° F to reach full-extend and full-retract DRAWN to ensureNAME
the
DATE
TWC 3/17/2014
internal limit
BEAR LINEAR
controlled temperature environment. Note normal wear, switches are activated. If this
PROPRIETARY AND CONFIDENTIAL
is not possible
CHECKED
ENG APPR.
another
JRZ 3/17/2014 TITLE
method
M-TRACK OUTLINE
temperature changes and load variations all affect the stroke for shutting off the actuator must
THE INFORMATION CONTAINED IN THIS be employed.
MFG APPR.
Q.A.
MATERIAL
Typical Applications
Light load and short distance applications
such as:
• UTV differential locks
• Transmission Shifting
Dimensions
in. mm in. mm in. mm in. mm in. mm in. mm
M-Track
8 7 6 5 4 3 2 1
Stroke 2 50 4 100 6 150 8 200 10 254 12 300
with
M TRACK FOR RUBBER A
Boot LN/LP 9.48 241 9.48 241 11.48 292 13.48 342 15.48 393 17.48 444
BELLOW APPLICATION B 11.48 292 13.48 342 17.48 444 21.48 546 25.48 647 29.48 749
Note: Special lengths available D
D
SPECIAL LENGTHS AVAILABLE
"A" RETRACTED
"B" EXTENDED
7.7
38.2 .30 8.3
1.50 ACTUATOR .33
9.5 BREATHER TUBE USED
BODY WIDTH
19.1 .38 (APPROX.) FOR PROPER VENTING
9.5
.75 33 .38
1.30 16.4
.65
C C
65
2.56 BOOT
[73.3]
73.3
2.892.89 ACTUATOR
ACTUATOR (APPROX.)
BODY BODY HEIGHT 52.2
HEIGHT
2.05
19.9
.79 ROD 6.50
45.7 6.35
ALL DIMENSIONS ARE NOMINAL 1.80 BOTH SIDES
38.1 2X .256 THRU
.250
1.50
UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets. 106.2
B 4.18 B
8 4 1
5
M-Track 1
Speed Performance Graphs Imperial
Current Draw
Measurements*
*Performance Chart Measurements are Nominal
M1-D012-0025
Load Capacity 25 lbs. Nominal Performance M1-D024-0025 Nominal Performance
For Metric Measurements, see page 12.
M1-D012-0025 Current Draw Speed M1-D024-0025 Current Draw Speed
2 1.74 1 1.74
1.71 1.71
1.75 0.875
Current Draw - Amps
Speed - IPS
Speed - IPS
1.5 0.75
1.65 1.65
1.25 0.625
1.62 1.62
1 0.5
1.59 1.59
M1-D012-0050
Load Capacity 50 lbs. Nominal Performance M1-D024-0050 Nominal Performance
For Metric Measurements, see page 12.
M1-D012-0050 Current Draw Speed M1-D024-0050 Current Draw Speed
1 1
2 1
Current Draw - Amps
0.995 0.995
Speed - IPS
Speed - IPS
1.5 0.99 0.75 0.99
0.98 0.98
0.5 0.25
0.975 0.975
0 0.97 0 0.97
0 10 20 30 40 50 0 10 20 30 40 50
Load - lbs Load - lbs
M1-D012-0100
Load Capacity 100 lbs.Nominal Performance M1-D024-0100 Nominal Performance
For Metric Measurements, see page 12.
M1-D012-0100 Current Draw Speed M1-D024-0100 Current Draw Speed
3.5 1.75
Speed - IPS
Speed - IPS
3 0.62 1.5 0.62
2.5 1.25
2 0.58 1 0.58
1.5 0.75
0.54 0.54
1 0.5
0.5 0.5 0.25 0.5
0 20 40 60 80 100 0 20 40 60 80 100
Load - lbs Load - lbs
Speed - IPS
2 0.4 1 0.4
M1-D012-0025
Load Capacity 111 N Nominal Performance M1-D024-0025 Nominal Performance
For Imperial Measurements, see page 11.
M1-D012-0025 Current Draw Speed M1-D024-0025 Current Draw Speed
2 44 1 44
1.75 43 0.875 43
Current Draw - Amps
Speed - MMPS
1.5 42 0.75 42
1.25 41 0.625 41
1 40 0.5 40
0.75 39 0.375 39
0 22 45 67 89 111 0 22 45 67 89 111
Load - N Load - N
M1-D012-0050
Load Capacity 223 N Nominal Performance M1-D024-0050 Nominal Performance
For Imperial Measurements, see page 11.
M1-D012-0050 Current Draw Speed M1-D024-0050 Current Draw Speed
Speed - MMPS
25.2 25.2
1.5 0.75
25.1 25.1
25 25
1 0.5
24.9 24.9
M1-D012-0100
Load Capacity 445 N Nominal Performance M1-D024-0100 Nominal Performance
For Imperial Measurements, see page 11.
M1-D012-0100 Current Draw Speed M1-D024-0100 Current Draw Speed
4.5 18 2.25 18
4 2
17 17
Current Draw - Amps
3.5 1.75
Speed - MMPS
Speed - MMPS
3 16 1.5 16
2.5 1.25
2 15 1 15
1.5 0.75
14 14
1 0.5
0.5 13 0.25 13
0 89 178 267 356 445 0 89 178 267 356 445
Load - N Load - N
M1-D012-0165
Load Capacity 734 N Nominal Performance M1-D024-0165 Nominal Performance
For Imperial Measurements, see page 11.
M1-D012-0165 Current Draw Speed M1-D024-0165 Current Draw Speed
3.5 11 1.75 11
Speed - MMPS
2 10.25 1 10.25
1.5 10 0.75 10
Dimensions
in. mm in. mm in. mm in. mm in. mm
S-Track Stroke 4 102 6 152 8 203 10 254 12 305
A 9.32 236.7 11.32 287.5 13.32 338.3 15.32 389.1 17.32 439.9
["A"]
"A" RETRACTED
STROKE TOLERANCE
IS +/-.078 [1.98]
[ 7.9 ] [ 181.1 ]
[ 51.6 ] .31 7.13
2.03 [9]
[ 14.5 ] .36
[ 43.9 ] .57
[ 11 ]
1.73 VENT FOR .125" [3.18] [ 37 ] .43
BREATHER TUBE 1.46
[ 32.2 ]
1.27
[19.92±0.13] [ 19.8 ]
Ø .784±.005 .78
[ 106.4 ]
4.19
[ 9.65
9.53 ]
Ø .380
.375 THRU
BOTH ENDS
MALE METRIPACK 150 (SHOWN)
MATES TO ACTUATOR HOUSING
[ 35.4 ] USE 16AWG WIRES
1.39 PIN A: LIVE POWER (+)
PIN B: EXTEND LIMIT OUTPUT ALL DIMENSIONS ARE NOMINAL
[ 69 ]
2.72 PIN C: LIVE INPUT UNLESS OTHERWISE SPECIFIED
PIN D: LIVE POWER (-) Measurements in inches, metric in brackets.
PIN E: RETRACT LIMIT OUTPUT
PIN F: POTENTIOMETER OUTPUT
PIN G: LIVE GROUND
PIN H: SIGNAL GROUND
S-Track Configurator
S1 P1 G11 – 12V – DN – 08 – 1
SIZE P
POT output and Limit G17 .50" 18 .375 - 8 screw WITHOUT THE WRITTEN PERMISSION OF TOLERANCES
C
Blank– STD
BEAR LINEAR IS PROHIBITED.
SCALE 2
Switches G26 .33" 18 .375 - 12 screw
7 6 5 4 R90 – 90
G35 .25" 18 .375 - 16 screw
K1 – Key Pad Control
Scan to watch!
Linear Actuator Basic Selection Video For Protective Boot
https://p.widencdn.net/ydtpk6 Consult factory for ordering details.
S Track G07-12VDC Current Draw Speed S Track G07-24VDC Current Draw Speed
4 1.07 2 1.07
Current Draw - Amps
Speed - IPS
3 1.03 1.5 1.03
2 0.99 1 0.99
6 0.83 3 0.83
0.77 0.77
4 2
Speed - IPS
Speed - IPS
0.74 0.74
3 1.5
0.71 0.71
2 1
0.68 0.68
1 0.65 0.5 0.65
0 0.62 0 0.62
0 25 50 75 100 125 150 175 0 25 50 75 100 125 150 175
Load - lbs Load - lbs
6 0.63 3 0.63
Speed - IPS
Speed - IPS
3 0.54 1.5 0.54
2 0.51 1 0.51
0 0.45 0 0.45
0 25 50 75 100 125 150 175 200 225 0 25 50 75 100 125 150 175 200 225
Load - lbs Load - lbs
4 0.52 2 0.52
Current Draw - Amps
Speed - IPS
Speed - IPS
2 0.46 1 0.46
0 0.4 0 0.4
0 25 50 75 100 125 150 175 200 225 250 0 25 50 75 100 125 150 175 200 225 250
Load - lbs Load - lbs
6 0.34 3 0.34
0.33 0.33
5 2.5
Current Draw - Amps
Speed - IPS
0.32 0.32
Speed - IPS
4 2
0.31 0.31
3 1.5
0.3 0.3
2 1
0.29 0.29
6 3
0.25 0.25
Current Draw - Amps
5 2.5
Speed - IPS
Speed - IPS
4 0.23 2 0.23
0 0.17 0 0.17
0 50 100 150 200 250 300 350 400 0 50 100 150 200 250 300 350 400
Load - lbs Load - lbs
4 27 2 27
Current Draw - Amps
Speed - MMPS
Speed - MMPS
3 26 1.5 26
2 25 1 25
1 24 0.5 24
0 111 223 334 445 556 0 111 223 334 445 556
Load - N Load - N
6 21 3 21
5 2.5
20 20
Current Draw - Amps
Speed - MMPS
4 2
19 19
3 1.5
18 18
2 1
17 17
1 0.5
0 16 0 16
0 111 223 334 445 556 668 779 0 111 223 334 445 556 668 779
Load - N Load - N
6 16 3 16
5 2.5
15 15
Current Draw - Amps
Speed - MMPS
4 2
14 14
3 1.5
13 13
2 1
12 12
1 0.5
0 11 0 11
0 111 223 334 445 556 668 779 890 1001 0 111 223 334 445 556 668 779 890 1001
Load - N Load - N
13 13
4 2
Current Draw - Amps
Speed - MMPS
12.5 12.5
Speed - MMPS
3 12 1.5 12
2 11.5 1 11.5
11 11
1 0.5
10.5 10.5
0 10 0 10
0 111 223 334 445 556 668 779 890 1001 1113 0 111 223 334 445 556 668 779 890 1001 1113
Load - N Load - N
6 8.5 3 8.5
8.25 8.25
5 2.5
Current Draw - Amps
Speed - MMPS
Speed - MMPS
8 8
4 2
7.75 7.75
3 1.5
7.5 7.5
2 1
7.25 7.25
1 7 0.5 7
0 223 445 668 890 1113 1335 0 223 445 668 890 1113 1335
Load - N Load - N
7 7 3.5 7
6 6.5 3 6.5
Current Draw - Amps
Speed - MMPS
5 2.5
Speed - MMPS
6 6
4 2
5.5 5.5
3 1.5
5 5
2 1
0 4 0 4
0 223 445 668 890 1113 1335 1558 1780 0 223 445 668 890 1113 1335 1558 1780
Load - N Load - N
Features
• Models available in 12VDC and 24VDC.
• Loads up to 200 lbs thrust.
• In-line design reduces base footprint.
• Releasing clutch allows rod to float with
clutch power-off. Clutch power is separate
from motor power.
• Clutch also acts as over-load protection.
• Motor thermal for added motor protection.
• Optional Potentiometer output scaled to
stroke.
Up to 200 lbs. (890 N) Rated Load
• Can be driven by PWM (not supplied)
Up to 1 in. (25 mm)/sec. Travel Speed controller to achieve multiple velocities.
I-Track is a general duty inline actuator suited for applications needing a • Can be mounted at the body by trunnions
power-off releasing the rod into a float mode. This unit utilizes a ball screw (shoulder bolts) or as traditional clevis.
and planetary drive for long life in a compact space. Models can be fitted • Rod end mounts are configurable.
with a potentiometer that is directly coupled to the rod that will provide
• Ball screw and nut for long life.
position feedback regardless if the rod is in float or locked mode. It can
be driven by PWM to control velocity. For controlling the float and locked • Operating temperatures -40° F to +185° F
rod setting there is a separate input independent of the motor connection. (-40° C to 85° C).
The rod can also be configured to be permanently locked for applications • Steel rod for durability.
where a floating rod is not required. The unit incorporates a ratchet-free
overload slip clutch to protect the drive system. • Nitrile impregnated gaskets for superior
sealing.
• Black powder coat for 250 hour salt spray
protection.
Specifications • Nitrotec® coated steel components for
Operating Voltage 9-15VDC or 22-26VDC 250 hour Salt Spray Protection.
Passed EMI Immunity • IP69K Static; IP66 Dynamic. Rod bellow
ISO 11452-4 Certified
Testing will allow for temporary operation IP67
Operating Load 200 lbs. (890 N) Thrust, 800 lbs. (3,559 N) Static submersion.
Stroke Length 2, 4, 6, 8, 10 and 12
Duty Cycle 25% max.
Typical Applications
No-Load Speed 1.1"/SEC (27.94 mm/sec) • Throttle controls
Floating Rod Design • Mobility lifts for vehicles requiring manual
Operation Temperatures operation in emergency situations
-40° F to 185° F (-40° C to 85° C)
Range • Hydraulic flow controls
Potentiometer 560-10K Optional
• Bus Door Operator
Environment IP69K Static, IP66 Dynamic
• Hatch lift applications
• Handicap Van Lifts
• Engine Controls
• Emergency Door (lock and unlock via VDC)
Imperial Measurements*
I Track G05-12VDC
I Track Operating Nominal Performance
Load 200 Lbs. I1XG05-24VDC Nominal Performance
G05-12VDC G05-24VDC Current Draw Speed
Amps
Draw -- Amps
7 3.5
Draw --Amps
1 1
IPS
IPS
Speed - IPS
6 3
Speed -- IPS
0.9 0.9
Current Draw
Current Draw
5 2.5
Speed
Speed
0.8 0.8
4 2
Current
Current
0.7 0.7
3 1.5
2 0.6 1 0.6
Metric Measurements*
I Track G05-12VDC
I Track Operating Load 890 N Nominal Performance I1XG05-24VDC Nominal Performance
G05-12VDC G05-24VDC Current Draw Speed
9 28 4.5 28
8 26 4 26
Amps
Amps
Draw -- Amps
7 3.5
Draw --Amps
24 24
MMPS
Speed - MMPS
Speed - MMPS
6 3
22 22
Current Draw
Current Draw
5 2.5
20 20
Speed
Speed
4 2
Current
Current
18 18
3 1.5
2 16 1 16
1 14 0.5 14
0 111 223 334 445 556 668 779 890 0 111 223 334 445 556 668 779 890
Load
Load --NN Load - N
Load
I-Track Configurator
Scan to watch!
Linear Actuator Basic Selection Video
https://p.widencdn.net/ydtpk6
E±0.50
E±.02
"A"±0.51
D±0.50
+0.25 "A"±.02
AA 9.53 - 0.25 D±.02 EE
+0.76
.01 22.86 - 0.51
+
.38 .01
- C±0.50 .03
2x Ø .27 .78 .90 +.02
M8X1.25 - 6H .63 C±.02 -
BB 31.81 FF
(Both Sides) B±0.50
1.25
B±.02
Retracted GG
DD
CC
+0.13 HH
9.55 0 Integral Connector Mates To Tyco
.005 Connector Part Number:
Ø .376 +.000 M10 X 1.5-6g
- 776494-1 8 Position, Socket Housing, Key Position 1 II
Connections: 15.75
Port 1= Motor (Connect-12vdc Tp Retract) .62 FLATS JJ
Port 2= Clutch (-12vdc) For Mounting
Port 3= Optional Potentiometer Input Vdc
+0.60
ALL DIMENSIONS ARE NOMINAL Port 4= Optional Potentiometer Input Vdc 36.97 - 0.20
Port 5= Optional Vent Tube (Consult Factory)
UNLESS OTHERWISE SPECIFIED Port 6= Optional Potentiometer Output Vdc .02
1.46 +.01
-
Measurements in inches, metric in brackets. Port 7= Clutch (+12vdc)
Port 8= Motor Connect (+12vdc To Retract)
Dimensions
in. mm in. mm in. mm in. mm in. mm in. mm in. mm
I1XG05-12V-XX
Stroke 2 50 3 75 4 100 6 150 8 200 10 254 12 300
OPERATING VOLTAGE: 9-15VDC FOR A12VDC NOMINAL
2.00 50.80 3.00 76.20 4.00 101.60 6.00 152.40 8.00 203.20 10.00 254.00 12.00 304.80
22-26VDC FOR 24VDC NOMINAL
I-Track -40 B TO1601.69F (-40 42.93
OPERATING TEMPERATURE: C TO 71 C)
2.69 68.33 3.69 93.73 5.69 144.53 7.69 195.33 9.69 246.13 11.69 296.93
ENVIRONMENT: IP66 OPERATING IP69K STATIC
PASSED EMI IMMUNITY TESTING C 7.65 194.31 8.65 219.71 9.65 245.11 11.65 295.91 13.65 346.71 15.65 397.51 17.65 448.31
OPERATING LOAD: 200 LBS THRUST 800 LBS STATIC
NO-LOAD SPEED: 1.1"/SEC D 13.29 337.57 14.29 362.97 15.29 388.37 17.29 439.17 19.29 489.97 21.29 540.77 23.29 591.57
FLOATING ROD DESIGN
OPTIONAL POTENTIOMETER E 14.42 366.27 15.42 391.67 16.42 417.07 18.42 467.87 20.42 518.67 22.42 569.47 24.42 620.27
Note: Special lengths available
AA
[ 36.49
+0.50
-0.20 ] DD
1.36±.02
HH
[29.54
+0.60
- 0.10 ] Monday, October 24, 2011 2:00:58 PM
DRAWN
NAME
JRZ
DATE
[ ]
1.44 +0.02 +0.02 CHECKED JRZ 9/10/2014 TITLE
DIMENSIONAL OUTLINE
+0.50 1.16
PROPRIETARY AND CONFIDENTIAL
ENG APPR.
- 0.20
THE INFORMATION CONTAINED IN THIS DIMENSIONS ARE IN MM
EE
Q.A.
DRAWING IS THE SOLE PROPERTY OF TOLERANCES:
INLINE ACTUATOR
COMMENTS:
+0.02 [30.31±0.51]
BB
[ 19.35
+0.40
-0.20 ] 3.62
- 0.01
II
1.16±.02
[ ] [ ]
+0.02
.76 +0.40 +0.40
-0.01 75.79 60.63
FF - 0.20 JJ - 0.20
+0.02 +0.02
CC
[
68.66
+0.40
-0.20 ] 2.98
- 0.01
2.39
- 0.01
+0.02 [19.91±0.25]
2.70 GG
-0.01 Ø .78±.01
How To Select
Step 1 – Determine Load and Stroke length requirements Step 6 – Select Nut Type
Use the Quick Selection guide to identify the model family that Select nut for unit selected. (K2x are all ball bearing).
will provide the load capacity and stroke length needed for your
application. Step 7 – Select Stroke Length
Choose standard lengths from chart. For special length
Step 2 – Determine Gear Ratio consult factory.
Select gear ratio from performance charts for allowable current
draw and needed load. Step 8 – Select end fitting orientation
Leave blank for standard orientation.
Step 3 – Identify motor type and voltage
Select DC motor and motor voltage.
B-Track Configurator
Motor Type
M – Ignition Protected Motor
For standard motor, leave blank.
Scan to watch!
Linear Actuator Basic Selection Video
https://p.widencdn.net/ydtpk6 CL CL LOCATION
OF CLEVIS PIN
K2vL units feature Nitrotec® corrosion protection on end fittings and • Bin and tank cover lifts
rods, high performance powder coat paint on cover tubes and gear • Remote engine clutch engagement
box covers, providing a totally sealed, weatherproof, and durable
finish for years of trouble-free service.
K2VLG05-12VDC
Load Capacity 200 lbs.Nominal Performance K2VLG05-24VDC Nominal Performance
For Metric Measurements, see page 26.
K2vlG05-12VDC Current Draw Speed K2vlG05-24VDC Current Draw Speed
3 3
20 10
Current Draw - Amps
Speed - IPS
Speed - IPS
15 7.5
2.5 2.5
10 5
2.25 2.25
5 2.5
2 2
0 1.75 0 1.75
0 25 50 75 100 125 150 175 200 0 25 50 75 100 125 150 175 200
Load - lbs Load - lbs
1.3 1.3
20 10
Current Draw - Amps
1.2 1.2
Speed - IPS
Speed - IPS
15 7.5
1.1 1.1
10 5
1 1
5 2.5
0.9 0.9
0 0.8 0 0.8
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Load - lbs Load - lbs
0.7 0.7
20 10
Current Draw - Amps
0.65 0.65
Speed - IPS
Speed - IPS
15 0.6 7.5 0.6
10 0.55 5 0.55
0.5 0.5
5 2.5
0.45 0.45
0 0.4 0 0.4
0 100 200 300 400 500 600 0 100 200 300 400 500 600
Load - lbs Load - lbs
K2VLG05-12VDC
Load Capacity 890 N Nominal Performance K2VLG05-24VDC Nominal Performance
For Imperial Measurements, see page 25.
K2vlG05-12VDC Current Draw Speed K2vlG05-24VDC Current Draw Speed
25 85 12.5 85
80 80
20 10
Current Draw - Amps
Speed - MMPS
Speed - MMPS
15 70 7.5 70
65 65
10 60 5 60
55 55
5 2.5
50 50
0 45 0 45
0 111 223 334 445 556 668 779 890 0 111 223 334 445 556 668 779 890
Load - N Load - N
K2VLG10-12VDC
Load Capacity 1335 N Nominal Performance K2VLG10-24VDC Nominal Performance
For Imperial Measurements, see page 25.
K2vlG10-12VDC Current Draw Speed
K2vlG10-24VDC Current Draw Speed
25 35 12.5 35
32.5 32.5
20 10
Current Draw - Amps
30 30
Speed - MMPS
Speed - MMPS
15 7.5
27.5 27.5
10 5
25 25
5 2.5
22.5 22.5
0 20 0 20
0 223 445 668 890 1113 1335 0 223 445 668 890 1113 1335
Load - N Load - N
K2VLG20-12VDC
Load Capacity 2670 N Nominal Performance K2VLG20-24VDC Nominal Performance
For Imperial Measurements, see page 25.
K2vlG20-12VDC Current Draw Speed K2vlG20-24VDC Current Draw Speed
25 18 12.5 18
17 17
20 10
Current Draw - Amps
16 16
Speed - MMPS
Speed - MMPS
15 15 7.5 15
10 14 5 14
13 13
5 2.5
12 12
0 11 0 11
0 445 890 1335 1780 2225 2670 0 445 890 1335 1780 2225 2670
Load - N Load - N
Dimensions
in. mm in. mm in. mm in. mm in. mm in. mm
B-Track
Stroke 2 51 4 102 6 152 8 203 10 254 12 305
K2vl
A 8.32 211.3 10.32 262.1 12.32 312.9 14.32 363.7 16.32 414.5 18.32 465.3
Note: Special lengths available
["A" ±3.18]
"A"±.125 RETRACTED
STROKE TOLERANCE
[78.63±0.38] IS +/- .060 [1.52]
3.08±.015
[11.43±0.38] [13.46±0.38]
.450±.015
[39.51±0.13] [50.80 +0.30
0 ]
.530±.015
1.54±.005 [16.63±1.52]
[28.58 -0.08
0
] .655±.060 Ø 2.000 +- .012
.000
[14.87±0.56]
.585±.022
Ø 1.125 +- .000
.003 (ROD)
[25.40±0.38]
[148.88±0.43] Ø 1.000±.015
5.861±.017
[109.76±0.30]
[12.93
12.78 ]
BARE WIRES
4.321±.012 Ø .509 THRU
.503
BOTH ENDS
[ 63.5 +0.3
-1.3 ]
Ø 2.50 +.01
- .05
10"/[254] LEAD WIRE LENGTH [24.24±0.46]
CONNECT (+) TO GRAY WIRE .954±.018
& (-) TO BLACK WIRE TO EXTEND
THE ACTUATOR [175.86±5.08]
ALL DIMENSIONS ARE NOMINAL PACKARD 56 CONNECTOR 6.924±.200
UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
8 7 6 5 4 1
The K2 uses a solid bronze or Delrin® nut with a rolled hybrid Acme style Typical Applications
screw yielding high impact capability and long screw life. Heavy-duty • Heavy duty platform and engine lifts
double-ended ball bearing motors, hardened gears, O-ring seals and an • Deck and implement lifts for tractors and
mobile applications
extension rod bearing system that provides best in class capabilities.
• Table positioning
Now Available Optional Adjustable Limit Switch These easy to use • Wheelchair and scooter lifts
adjustable switches are mounted in a channel on the cover tube with • Bin and tank cover lifts
custom cap for protection. They are easily moved to enable the end-user • Flow gate open/close
the flexibility of setting the stroke length at any position within the full Scan to watch!
stroke capability. Just pop the cap off, loosen the set screw and slide the How to Adjust the Limit Switches for a K2 or
K2X Actuator with External or EP Limit Switches
switch into the desired position. https://p.widencdn.net/imzc9v
K2G05-12VDC
Load Capacity 300 lbs.Nominal Performance K2G05-24VDC Nominal Performance
For Metric Measurements, see page 30.
K2G05-12VDC Current Draw Speed
K2G05-24VDC Current Draw Speed
25 3 12.5 3
2.75 2.75
20 10
Current Draw - Amps
Speed - IPS
2.5 2.5
Speed - IPS
15 7.5
2.25 2.25
10 5
2 2
5 2.5
1.75 1.75
0 1.5 0 1.5
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Load - lbs Load - lbs
20 1.3 10 1.3
Current Draw - Amps
Speed - IPS
15 1.1 7.5 1.1
10 0.9 5 0.9
0 0.5 0 0.5
0 100 200 300 400 500 600 0 100 200 300 400 500 600
0.7 0.7
20 10
Current Draw - Amps
0.64 0.64
Speed - IPS
Speed - IPS
15 0.58 7.5 0.58
10 0.52 5 0.52
0.46 0.46
5 2.5
0.4 0.4
0 0.34 0 0.34
0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200
0.44 0.44
20 10
Current Draw - Amps
0.42 0.42
Speed - IPS
Speed - IPS
10 0.38 5 0.38
0.36 0.36
5 2.5
0.34 0.34
0 0.32 0 0.32
0 300 600 900 1200 1500 0 300 600 900 1200 1500
Load - lbs Load - lbs
K2G05-12VDC
Load Capacity 1335 NNominal Performance K2G05-24VDC Nominal Performance
For Imperial Measurements, see page 29.
K2G05-12VDC Current Draw Speed
K2G05-24VDC Current Draw Speed
25 76 12.5 76
70 70
20 10
Current Draw - Amps
Speed - IPS
15 7.5
58 58
10 5
52 52
5 2.5
46 46
0 40 0 40
0 223 445 668 890 1113 1335 0 223 445 668 890 1113 1335
Load - N Load - N
K2G10-12VDC
Load Capacity 2670 NNominal Performance K2G10-24VDC Nominal Performance
For Imperial Measurements, see page 29.
K2G10-12VDC Current Draw Speed
K2G10-24VDC Current Draw Speed
25 40 12.5 40
35 35
20 10
Current Draw - Amps
Speed - MMPS
30 30
15 7.5
25 25
10 5
20 20
5 2.5
15 15
0 10 0 10
0 445 890 1335 1780 2225 2670 0 445 890 1335 1780 2225 2670
Load - N Load - N
K2G20-12VDC
Load Capacity 5340 NNominal Performance K2G20-24VDC Nominal Performance
For Imperial Measurements, see page 29.
K2G20-12VDC Current Draw Speed
K2G20-24VDC Current Draw Speed
25 20 12.5 20
18 18
20 10
Current Draw - Amps
Speed - MMPS
16 16
15 7.5
14 14
10 5
12 12
5 2.5
10 10
0 8 0 8
0 890 1780 2670 3560 4450 5340 0 890 1780 2670 3560 4450 5340
Load - N Load - N
K2G30-12VDC
Load Capacity 6675 NNominal Performance K2G30-24VDC Nominal Performance
For Imperial Measurements, see page 29.
K2G30-12VDC Current Draw Speed
K2G30-24VDC Current Draw Speed
25 12 12.5 12
11.5 11.5
20 10
Current Draw - Amps
11 11
Speed - IPS
Speed - IPS
7 6 5 4 3 2 1
in. mm in. mm in. mm in. mm in. mm in. mm
B-Track K2 Stroke 14 356 16 406 18 457 20 508 22 559 24 610
A 20.32 516.1 22.32 566.9 24.32 617.7 29.32 744.7 31.32 795.5 33.32 846.3
Note: Special lengths available
["A"] ±3.18
"A" ±.125 RETRACTED
NOMINAL STROKE IS .091 [2.31]
LONGER THAN ADVERTISED
[78.23±0.38] TOLERANCE IS +.036/-.005 [+.91/-.13]
3.080±.015 [11.43±0.38] [13.46±0.38]
.450±.015 .530±.015
[39.12±0.13]
[18.31±1.52] [50.80 +0.30
0 ] [14.87±0.56]
1.540±.005
[ 28.58 -00.08 ] .721±.060
Ø 2.000 +-.012 .585±.022
.000 .000
Ø 1.125 +-.003 (ROD)
[25.40±0.38]
[148.88±0.43] Ø 1.000±.015
5.861±.017 [ 12.93
12.78]
[109.76±0.30] Ø .509 THRU
.503
4.321±.012 BOTH ENDS WIRES PROTECTED WITH [ 63.5 +0.3
-1.3 ]
BLACK SPIRAL WRAP
Ø 2.50 +.01
- .05
10" [254] LEAD WIRE LENGTH
[24.24±0.46]
CONNECT (+) TO GRAY WIRE .954±.018
& (-) TO BLACK WIRE TO EXTEND
THE ACTUATOR
PACKARD 56 CONNECTOR [177±5.08]
ALL DIMENSIONS ARE NOMINAL 6.969±.200
UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
7 6 5 4
8 7 6 5 4 3 2 1
["A" ±3.18]
"A" ±.125 RETRACTED
NOMINAL STROKE IS .091
LONGER THAN ADVERTISED
[78.23±0.38] TOLERANCE IS +.036/-.005
[11.11±0.38] [13.46±0.38]
3.080±.015 .438±.015 .530±.015
[39.12±0.13]
0 [31.18±1.52] [50.80 +0.30
0 ] [14.87±0.56]
1.540±.005
[ 28.58 -0.08 ] 1.228±.060 Ø 2.000 +.012
- .000
.585±.022
Ø 1.125 +.000 (ROD)
-.003
[25.40±0.38]
[156.39±0.43] Ø 1.000±.015
6.157±.017 [12.93
12.78 ]
[117.28±0.30] .509
Ø .503 THRU
4.617±.012
BOTH ENDS
23.5" [597] CABLE W/18AWG WIRES
HOT TO RED WIRE TO EXTEND [24.2±0.46]
HOT TO BLACK WIRE TO RETRACT
.954±.018
WHITE WIRE IS NEUTRAL
GROUND TO GREEN WIRE
86.9 +-1.3
0.3
[ ]
ALL DIMENSIONS ARE NOMINAL
Ø 3.42 .01
+
UNLESS OTHERWISE SPECIFIED - .05
[320.68±5.08]
Measurements in inches, metric in brackets. 12.625±.200
8 7 6 5 4 1
K2G10-115VAC
Load Capacity 500 lbs.Nominal Performance K2G10-230V Nominal Performance
For Metric Measurements, see page 35.
K2G10-115Vac Current Draw Speed
K2G10-230Vac Current Draw Speed
Speed - IPS
Speed - IPS
2.8 1.45
1.02 1.02
2.7 1.4
1 1
2.6 1.35
0.98 0.98
2.5 1.3
2.4 0.96 1.25 0.96
K2G20-115VAC
Load Capacity 750 lbs.Nominal Performance K2G20-230VAC Nominal Performance
For Metric Measurements, see page 35.
Current Draw Speed Current Draw Speed
K2G20-115Vac K2G20-230Vac
2.7 0.6 1.35 0.6
2.65 1.325
0.58 0.58
Current Draw - Amps
2.6 1.3
Speed - IPS
Speed - IPS
2.55 0.56 1.275 0.56
2.5 1.25
2.45 0.54 1.225 0.54
2.4 1.2
0.52 0.52
2.35 1.175
2.3 0.5 1.15 0.5
0 150 300 450 600 750 0 150 300 450 600 750
Load - lbs Load - lbs
K2G30-115VAC
Load Capacity Nominal Performance
1100 lbs. K2G30-230VAC Nominal Performance
For Metric Measurements, see page 35.
K2G30-115Vac Current Draw Speed
K2G30-230Vac Current Draw Speed
1.24
2.45 0.38 0.38
Speed - IPS
Speed - IPS
1.22
2.4 0.37 0.37
1.2
2.35 0.36 0.36
1.18
2.3 0.35 1.16 0.35
K2G10-115VAC
Load Capacity 2225 N Nominal Performance K2G10-230VAC Nominal Performance
For Imperial Measurements, see page 34.
K2G10-115Vac Current Draw Speed
K2G10-230Vac Current Draw Speed
Speed - MMPS
Speed - MMPS
2.8 1.45
26 26
2.7 1.4
25.5 25.5
2.6 1.35
25 25
2.5 1.3
2.4 24.5 1.25 24.5
2.3 24 1.2 24
0 445 890 1335 1780 2225 0 445 890 1335 1780 2225
Load - N Load - N
K2G20-115VAC
Load Capacity 3338 N Nominal Performance K2G20-230VAC Nominal Performance
For Imperial Measurements, see page 34.
Current Draw Speed Current Draw Speed
K2G20-115Vac K2G20-230Vac
2.7 15 1.35 15
2.65 1.325
14.5 14.5
Current Draw - Amps
2.6 1.3
Speed - MMPS
Speed - MMPS
2.55 14 1.275 14
2.5 1.25
2.45 13.5 1.225 13.5
2.4 1.2
13 13
2.35 1.175
2.3 12.5 1.15 12.5
0 668 1335 2003 2670 3338 0 668 1335 2003 2670 3338
Load - N Load - N
K2G30-115VAC
Load Capacity 4895 N Nominal Performance K2G30-230VAC Nominal Performance
For Imperial Measurements, see page 34.
K2G30-115Vac Current Draw Speed
K2G30-230Vac Current Draw Speed
2.5 10 1.26 10
Current Draw - Amps
Speed - MMPS
2.45
9.6 1.22 9.6
2.4
9.4 1.2 9.4
2.35
9.2 1.18 9.2
2.3 9 1.16 9
K2XG05-12VDC
Load Capacity 600 lbs.Nominal Performance K2XG05-24VDC Nominal Performance
For Metric Measurements, see page 38.
K2XG05-12VDC Current Draw Speed K2XG05-24VDC Current Draw Speed
2.5 2.5
20 10
Current Draw - Amps
Speed - IPS
Speed - IPS
15 2 7.5 2
10 1.75 5 1.75
1.5 1.5
5 2.5
1.25 1.25
0 1 0 1
0 100 200 300 400 500 600 0 100 200 300 400 500 600
Load - lbs Load - lbs
K2XG10-12VDC
Load Capacity Nominal Performance
1200 lbs. K2XG10-24VDC Nominal Performance
For Metric Measurements, see page 38.
K2XG10-12VDC Current Draw Speed
K2XG10-24VDC Current Draw Speed
20 1.4 10 1.4
Current Draw - Amps
Speed - IPS
15 1.2 7.5 1.2
10 1 5 1
0 0.6 0 0.6
0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200
Load - lbs Load - lbs
K2XG20-12VDC
Load Capacity Nominal Performance
2200 lbs. K2XG20-24VDC Nominal Performance
For Metric Measurements, see page 38.
K2XG20-12VDC Current Draw Speed
K2XG20-24VDC Current Draw Speed
0.7 0.7
20 10
Current Draw - Amps
0.6 0.6
Speed - IPS
Speed - IPS
15 7.5
0.5 0.5
10 5
0.4 0.4
5 2.5
0.3 0.3
0 0.2 0 0.2
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Load - lbs Load - lbs
K2XG30-12VDC
Load Capacity Nominal Performance
2800 lbs. K2XG30-24VDC Nominal Performance
For Metric Measurements, see page 38.
0.45 0.45
20 10
Current Draw - Amps
0.43 0.43
Speed - IPS
Speed - IPS
10 0.39 5 0.39
0.37 0.37
5 2.5
0.35 0.35
0 0.33 0 0.33
0 400 800 1200 1600 2000 2400 2800 0 400 800 1200 1600 2000 2400 2800
Load - lbs Load - lbs
K2XG05-12VDC
Load Capacity 2670 N Nominal Performance K2XG05-24VDC Nominal Performance
For Imperial Measurements, see page 37.
K2XG05-12VDC Current Draw Speed K2XG05-24VDC Current Draw Speed
25 70 12.5 70
20 60 10 60
Current Draw - Amps
Speed - MMPS
15 50 7.5 50
10 40 5 40
5 30 2.5 30
0 20 0 20
0 445 890 1335 1780 2225 2670 0 445 890 1335 1780 2225 2670
Load - N Load - N
K2XG10-12VDC
Load Capacity 5340 N Nominal Performance K2XG10-24VDC Nominal Performance
For Imperial Measurements, see page 37.
K2XG10-12VDC Current Draw Speed K2XG10-24VDC Current Draw Speed
25 40 12.5 40
20 35 10 35
Current Draw - Amps
Speed - MMPS
15 30 7.5 30
10 25 5 25
5 20 2.5 20
0 15 0 15
0 890 1780 2670 3560 4450 5340 0 890 1780 2670 3560 4450 5340
Load - N Load - N
K2XG20-12VDC
Load Capacity 9790 N Nominal Performance K2XG20-24VDC Nominal Performance
For Imperial Measurements, see page 37.
K2XG20-12VDC Current Draw Speed K2XG20-24VDC Current Draw Speed
25 20 12.5 20
18 18
20 10
Current Draw - Amps
16 16
Speed - MMPS
Speed - MMPS
15 14 7.5 14
10 12 5 12
10 10
5 2.5
8 8
0 6 0 6
0 890 1780 2670 3560 4450 5340 6230 7120 8010 8900 9790 0 890 1780 2670 3560 4450 5340 6230 7120 8010 8900 9790
Load - N Load - N
K2XG30-12VDC
Load Capacity Nominal Performance
12,460 N K2XG30-24VDC Nominal Performance
For Imperial Measurements, see page 37.
K2XG30-12VDC Current Draw Speed K2XG30-24VDC Current Draw Speed
25 12 12.5 12
11.5 11.5
20 10
Current Draw - Amps
11 11
Speed - MMPS
Speed - MMPS
10 10 5 10
9.5 9.5
5 2.5
9 9
0 8.5 0 8.5
0 1780 3560 5340 7120 8900 10680 12460 0 1780 3560 5340 7120 8900 10680 12460
Load - N Load - N
7 6 5 4 3 2
["A"±3.18]
"A" ±.125 RETRACTED
NOMINAL STROKE IS .091 [2.31]
LONGER THAN ADVERTISED
[78.23±0.38] TOLERANCE IS +.036/-.005 [+.91/-.13]
3.080±.015
[11.43±0.38] [13.46±0.38]
.450±.015 .530±.015
[39.12±0.13]
1.540±.005 [18.51±1.52]
[
50.80 +0.30
0 ]
[ 0
]
28.58 - 0.08 .729±.060 .012
Ø 2.000 +.000
-
[14.87±0.56]
.585±.022
+.000
Ø 1.125 - .003 (ROD)
[25.40±0.38]
[148.88±0.43] Ø 1.000±.015
5.861±.017
[109.76±0.30] [ 12.93
12.78 ]
4.321±.012
Ø .509 THRU
WIRES PROTECTED WITH
BLACK SPIRAL WRAP
[63.5 +0.3
- 1.3 ]
.503
BOTH ENDS Ø 2.50 +.01
- .05
[24.24±0.46]
10" [254] LEAD WIRE LENGTH .954±.018
CONNECT (+) TO GRAY WIRE
& (-) TO BLACK WIRE TO EXTEND
THE ACTUATOR [177±5.08]
PACKARD 56 CONNECTOR 6.969±.200
7 6 5 4
K2XG05-115VAC
Load Capacity 500 lbs. Nominal Performance K2XG05-230VAC Nominal Performance
For Metric Measurements, see page 42.
Current Draw Speed
K2xG05-115Vac Current Draw Speed K2xG05-230Vac
3.25 1.8 1.7 1.8
1.6 1.7
1.7
3
Current Draw - Amps
Speed - IPS
Speed - IPS
2.75 1.4
1.5 1.5
1.3
2.5
1.4 1.4
1.2
2.25 1.3
1.3 1.1
2 1.2 1 1.2
0 100 200 300 400 500 0 100 200 300 400 500
Load - lbs Load - lbs
K2XG10-115VAC
Load Capacity 1000 lbs.Nominal Performance K2XG10-230VAC Nominal Performance
For Metric Measurements, see page 42.
K2xG10-115Vac Current Draw Speed K2xG10-230Vac Current Draw Speed
Speed - IPS
2.8 1.02 1.4 1.02
2.7 1 1.35 1
K2XG20-115VAC
Load Capacity 1500 lbs.Nominal Performance K2XG20-230VAC Nominal Performance
For Metric Measurements, see page 42.
Current Draw Speed Current Draw Speed
K2xG20-115Vac K2xG20-230Vac
2.7 0.56 1.36 0.56
Speed - IPS
2.55 0.53 0.53
1.27
2.5 0.52 0.52
1.24
2.45 0.51 0.51
K2XG30-115VAC
Load Capacity 2000 lbs.Nominal Performance K2XG30-230VAC Nominal
For MetricPerformance
Measurements, see page 42.
K2xG30-115Vac Current Draw Speed K2xG30-230Vac Current Draw Speed
1.24
2.45 0.38 0.38
Speed - IPS
Speed - IPS
1.22
2.4 0.37 0.37
1.2
2.35 0.36 0.36
1.18
2.3 0.35 1.16 0.35
K2XG05-115VAC
Load Capacity 2225 N Nominal Performance K2XG05-230VAC Nominal Performance
For Imperial Measurements, see page 41.
K2xG05-115Vac Current Draw Speed K2xG05-230Vac Current Draw Speed
3.25 45 1.7 45
1.6
3 42.5 42.5
Current Draw - Amps
Speed - MMPS
Speed - MMPS
2.75 40 1.4 40
2 32.5 1 32.5
0 445 890 1335 1780 2225 0 445 890 1335 1780 2225
Load - N Load - N
K2XG10-115VAC
Load Capacity 4450 N Nominal Performance K2XG10-230VAC Nominal Performance
For Imperial Measurements, see page 41.
3 27 1.5 27
Current Draw - Amps
Speed - MMPS
2.8 26 1.4 26
2.6 25 1.3 25
2.4 24 1.2 24
0 890 1780 2670 3560 4450 0 890 1780 2670 3560 4450
Load - N Load - N
K2XG20-115VAC
Load Capacity 6675 N Nominal Performance K2XG20-230VAC Nominal Performance
For Imperial Measurements, see page 41.
K2xG20-115Vac Current Draw Speed K2xG20-230Vac Current Draw Speed
2.65 14 1.33 14
Current Draw - Amps
Speed - MMPS
1.3
2.55 13.5 13.5
1.27
2.5 13.25 13.25
1.24
2.45 13 13
K2XG30-115VAC
Load Capacity 8900 N Nominal Performance K2XG30-230VAC Nominal Performance
For Imperial Measurements, see page 41.
K2xG30-115Vac Current Draw Speed K2xG30-230Vac Current Draw Speed
2.55 10 1.28 10
1.24
Speed - MMPS
Speed - MMPS
["A" ±3.18]
"A" ±.125 RETRACTED
NOMINAL STROKE IS .091
LONGER THAN ADVERTISED
[11.11±0.38] TOLERANCE IS +.036/-.005 [+.91/-.13]
[78.23±0.38] [13.46±0.38]
3.080±.015 .438±.015 .530±.015
[39.12±0.13]
1.540±.005
[ 0
28.58 -0.08 ] [31.30±1.52] [50.80 +0.30
0 ] [14.87±0.56]
+.000 1.232±.060 .585±.022
Ø 1.125 -.003 (ROD) Ø 2.000 +-.012
.000
[25.40±0.38]
Ø 1.000±.015
[156.39±0.43]
6.157±.017 [ ]
12.93
12.78
[117.28±0.30] Ø .509
.503
THRU
4.617±.012
BOTH ENDS
23.5" [597] CABLE W/18AWG WIRES
HOT TO RED WIRE TO EXTEND [24.24±0.46]
.954±.018
HOT TO BLACK WIRE TO RETRACT
WHITE WIRE IS NEUTRAL
[86.9 +-1.3
0.3
]
ALL DIMENSIONS ARE NOMINAL GROUND TO GREEN WIRE Ø 3.42 +.01
- .05
UNLESS OTHERWISE SPECIFIED [320.68±5.08]
Measurements in inches, metric in brackets. 12.625±.200
8 7 6 5 4 1
ROD END
.72 OPTION #4
.45
STANDARD Warner Linear offers a broad range of standard actuators
3.04 to suit many
D
ROD END needs. We realize though, that often special application parameters dictate
special actuator configurations and modifications. Warner1.36
Linear actuators
Ø .509
.503 THRU
are designed with this in mind, asR.75
many of our products can be readily
customized to suit specific requirements. Ø1
Our products
1.36
are built on modules that can be mixed and matched in final
assembly. Our final assembly operations
Ø .63 THRU are configured to provide flexible
5/8-18 THREADS Ø .509
.503 THRU
ROD END assembly to accommodate custom orders, quickly and cost effectively.
OPTION #1
C
If your application has a special need that our standard catalog products
8 7
1/2-20 UNF-2A
6 are unable to fit,
5 please contact 4your Warner Linear3 .53
representative or2
X .88 DEEP
Examples of special consult with our technical specialists so we can configure
(2) a product to fit
request features ROD END FLATS .44 ROD END
8
.72
7 your6 need. 5
OPTION #4 4 3
OPTION
2
#5 1.27
.45 ROD END
A few of our standard special offerings: 1.27 RO
3.04
ROD END
STANDARD .72 1.36 OPTION #4 Ø 1.00 OPT
D
ROD END .45
OPTION
• Special pin to pin lengths and stroke #6
lengths .44
1.36 3.04 1.2
STANDARD ROD END
D
Ø .509
ROD END OPTION #2 • Special endR.75
fittings and mounting configurations
.503 THRU 1.36 .509
.44
B
5/8-18 UNF-2A • Special paints and motor lead wire lengths and connectors Ø .503 THRU
Ø 1.00 1.23
R.75
Ø .509
.503 THRU
X .75 DEEP
1.36 Ø 1.00
B-Track Rod End Mounting Options Ø .63 THRU 5/8-18 THREADS
Dimensions are in inches
Ø .509
.503
.72
THRU
ROD
7 END 6 5 3.04 4 2 1.20
8
1.36 3 1
8 7 6
Rod End
5 4 3 Rod End 2
.45
1
Ø .509
OPTION #1 Ø .63 THRU Option 6 5/8-18ROD
THREADS .503 THRU
8 7 6 Option5 3 ROD
ROD
4 END
END 3 2
ROD END END 1 1.20
C
ROD END1/2-20 UNF-2A 1.36 ROD END OPTION
STANDARD .45
.72
.72OPTION #1 X .88 DEEP
OPTION
OPTION
ROD END #4#4 .53 OPTION
ROD END #5#5
R.66 OPTION
(2) #7
Rod End .45 .72
C OPTION #43.04 OPTION1.27#5
TANDARD 1/2-20 UNF-2A 3.04 FLATS
FLATS 1.27
.44 CREATED
NDARD .45 ROD ENDX .88 DEEP .53 Ø .38 THRU D
ROD END
D END A 3.04 (2).44.44 1.271.27 D
NDARD OPTION #3 1.36
DRAWN
8 6 5 4 1.36 FLATS
2 .44 D
CHECKED
D END 7
R.75 ROD END
3
.44
PROPRIETARY AND CONFIDENTIAL 1 UNLESS NOTED: ENG APPR.
OPTION #6
TOLERANCES:
R.75
FINISH:
.509 OPTION 1/2-20
#4 THREADS ROD END Ø 1.00
REPRODUCTION IN PART OR AS A WHOLE
OPTION #5
.X = +/-.060" & MAX FINISH 250 Ra
1.36 3.04 3
ARD 1.36 8 7 6 5 .509 .509
B
ROD END5/8-18 UNF-2A Rod End
Ø .63 THRU 5/8-18 THREADS Ø
Ø
.509 .503 THRU
THRUØ .503 THRU 1.23 D
ND Rod End 1.36
OPTION #2 X .75 DEEP Ø .63 THRU
Option 4 5/8-18 THREADS .503 .44 1.20
DOD END
END Option 1 Ø .63 THRU
1.36
5/8-18 THREADS Ø .509
.503 THRU 1.20.509
PTION
ON #1#1
B
5/8-18 UNF-2A R.75 Ø .503 THRU
1.20 1.23
END Ø .509
.503 THRU X .75 DEEP .72 C
ON #1 1/2-20 UNF-2A
1/2-20 XUNF-2A 3.04 .53 Rod ØEnd 1.00
C
RodUNF-2A
1/2-20 End Option 5 Ø D1.00 JRZ
DOD END
CHECKED 4/22/2014 TITLE
BASEAugust
CLEVIS
END Option
X .88 DEEP2 ROD 1.36END OPTION #6.44 .53 PROPRIETARY AND CONFIDENTIAL
Ø .38 THRU DIMENSIONS ARE IN INCHES
UNLESS NOTED:
CREATEDWednesday,
ENG APPR.
18
PTION
ON #2#2 A (2) THE INFORMATION CONTAINED IN THIS TOLERANCES:
MFG APPR.
W
NAME
MATERIAL DATE
R.75 5/8-18 UNF-2A THRU FLATS .509 THRU.44 REPRODUCTION WARNER LINEAR. ANY .XX = +/-.010" & MAX FINISH 125 Ra
B JRZ 4/22/2014 TITLE
Ø .503
CHECKED
.509 1.23
IN PART OR AS A WHOLE
FINISH:
ON #2
.X = +/-.060" & MAX FINISH 250 Ra
5/8-18 XUNF-2A 1/2-20 THREADS Ø .503 THRU 1.23
PROPRIETARY AND CONFIDENTIAL
WITHOUT THE WRITTEN PERMISSION OF ANGULAR: +/- 3 UNLESS NOTED: B ENG APPR.
Ø .50 THRU 1.23 WARNER LINEAR. ANY .XX = +/-.010" & MAX FINISH 125 Ra
SCALE 1:2
OPTION #6
WARNER LINEAR IS PROHIBITED. GEOMETRIC TOLERANCING PER ANSI Y14.9
.72 BREAK ALL CORNERS .010" NO SHARP BURRS
B Base
3.04 .72
Ø7 .509 4
SCALE 1:2
XR.66
.75 DEEP 1.36
OPTION
OPTION #7#7 C
Rod End Mounting .53
R.66 Option Examples ROD END
OPTION #7 options)
CREATEDWednesday, August 18, 2010 10:35:10 AM 1
ROD END
D END (Available for B-Track
R.66 (2) models only, consult factory for more Ø .38 THRU
Ø .38 THRU 6
CREATEDWednesday, August 18, 2010 10:35:10 AM
NAME
W ARNER L INEAR
DATE
A
PTION #3 FLATS .44 TAJ
W 2010 L INEAR
NAME DATE4/22/2014
.72
DRAWN
CREATEDWednesday, TAJ JRZ August 18, ARNER 10:35:10 AM A
ON #3 3JRZ
DRAWN 4/22/2014
D END
4/22/2014 TITLE
3.04 Ø .38 THRU
CHECKED
4/22/2014 BASE CLEVIS OPTIONS
TITLE
1.27 PROPRIETARY AND CONFIDENTIAL
W ARNER L INEAR
CHECKEDENG APPR.NAME DATE
UNLESS NOTED:
BASE CLEVIS OPTIONS
1. 1/2" Threaded rod end 5. 1" Extended rod end A
PROPRIETARY AND CONFIDENTIAL
ON #3 THE.45
UNLESSDIMENSIONS TAJ
NOTED: ARE IN INCHES ENG APPR.
DRAWN MFG APPR.
4/22/2014 MATERIAL
INFORMATION CONTAINED IN THIS TOLERANCES:
DIMENSIONS ARE IN INCHES
JRZ
MFG APPR.
CHECKED 4/22/2014 MATERIAL
TITLE
BASE CLEVIS OPTIONS
DRAWING CONTAINED
THE INFORMATION IS THE SOLEINPROPERTY
THIS OF TOLERANCES:.XXX = +/-.005" & MAX FINISH 60 Ra Q.A.
ROD
Ø .50
Ø .50 THRU END
THRU
Ø 1.00
PROPRIETARY
DRAWING ISAND CONFIDENTIAL
THEWARNER
SOLE LINEAR. OF
PROPERTY ANY .XX = +/-.010"
.XXXNOTED:
UNLESS = +/-.005" & MAX 60
& MAX FINISH FINISH
Ra 125 Ra Q.A.
ENG APPR.
FINISH:
OPTION
WITHOUT
REPRODUCTION
THE INFORMATION THE WRITTEN
IN PART OR AS IN
CONTAINED PERMISSION
A WHOLE
THIS OF TOLERANCES: ANGULAR:&+/-
.X = +/-.060" MAX3 FINISH 250 Ra
THREADS
SIZE DRAWING NUMBER REV.
WITHOUT IS WARNER
THE SOLELINEAR
WRITTEN IS PROHIBITED.
PERMISSIONOF OF =GEOMETRIC
+/- 3&TOLERANCING
MAX FINISH 60PERRa ANSI Y14.9
DRAWING THE PROPERTY ANGULAR:
.XXX +/-.005" Q.A.
B Base Options NW
OPTION #7
SIZE DRAWING NUMBER
Ø .50 THRU
REV.
WARNER
WARNERLINEAR IS PROHIBITED.
LINEAR. ANY .XX =BREAK
GEOMETRIC ALL&CORNERS
TOLERANCING PER.010"
125NO
ANSI RaSHARP BURRS
Y14.9
+/-.010" MAX FINISH
B Base Options NW
R.66
FINISH: SCALE 1:2 SHEET 3 OF 3
REPRODUCTION IN PART OR AS A WHOLE BREAK
.X =ALL CORNERS .010"FINISH
NO SHARP
250 RaBURRS
3. 1/2" Spherical 7.
+/-.060" & MAX
8
8
7
7 rod end
1/2-20 THREADS
6
3/8"
6 Rod end insert 5
WITHOUT THE WRITTEN PERMISSION OF
4
WARNER LINEAR IS PROHIBITED.
4
ANGULAR: +/- 3
GEOMETRIC TOLERANCING PER 3
3
ANSI Y14.9
CREATEDWednesday,
2
2 August 18, 2010
B Base Options
SCALE 1:2
1
SIZE DRAWING NUMBER
10:35:10 AM 1 NW
SHEET 3 OF 3
REV.
5
ND Ø .38 THRU BREAK ALL CORNERS .010" NO SHARP BURRS
SCALE 1:2 SHEET 3 OF 3
W ARNER L INEAR
NAME DATE
7
UNLESS NOTED: ENG APPR.
DIMENSIONS ARE IN INCHES MFG APPR. MATERIAL
1/2-20 THREADS .72 WITHOUT THE WRITTEN PERMISSION OF ANGULAR: +/- 3 SIZE DRAWING NUMBER REV.
Standard
WARNER LINEAR IS PROHIBITED. GEOMETRIC TOLERANCING PER ANSI Y14.9
BREAK ALL CORNERS .010" NO SHARP BURRS
B Base Options NW
SCALE 1:2 SHEET 3 OF 3
8 7 .45 6 5
4 3 2 1
44 Warner Linear 800-825-6544 ..... P-1581-WL 8/17
ROD END
Custom Actuator Solutions
We recognize how critical our actuators are to the overall Warner Linear routinely provides actuators modified to
performance of your equipment. Working closely with your meet specific customer application requirements
engineering and development staff, we strive for an early
understanding of how you want your linear actuator to Some common versions of these are shown as our K2PL/
perform. K2XPL and K2JS/K2XJS families.
Building a direct communication line from our engineer to
your engineer provides a number of significant benefits. Additional common modifications are:
• A teaming of creative resources
• Joint understanding of our actuator capabilities and how
they can be tailored to your application
Modified Seal design for expanded
contamination protection
• An understanding of the lowest cost solution to meet your
actuator requirements
5 • Providing a complete solution that includes controls as
4 3 2 1
required
Tube/Trunnion Mount F
"XI"
(Customer To Specify Full Retract)
Modified Seal
.67
DRAWN 5/12/2010
SPHERICAL
SPHERICAL
SIZE PART NUMBER REV.
REPRODUCTION IN PART OR AS A WHOLE
C trunnnion mount NW
Ø 1.00 Ø 1.00 WITHOUT THE WRITTEN PERMISSION OF
BEAR LINEAR IS PROHIBITED.
Ø .63
BASE5/8-18
5/8-18
SCALE 1:1 SHEET 1 OF 1
Ø 1.00 Ø 1.00
LUNT
ASE
LUNT
5 4 Ø .63
THREADED BASEØ .635/8-18 Ø .63
BASE
1
SPHERICAL
BASE 5/8-18 5/8-18 UNF-2A
ASE
Ø 1.00 B SPHERICAL X .62 DEEP
ASE
Ø 1.00
BASE 5/8-185/8-18 THREADS
5/8-18 THREADS
Ø .63
5/8-18 THREADS
Ø .63
5/8-18 THREADS BASE 5/8-18
BASE 5/8-18
1.48 1.48 5/8-18 UNF-2A
1.48 1.48 5/8-18 THREADS X .62 DEEP
B 5/8-18 THREADS
3.36 3.36 1.48 1.48
3.36 1.483.36
3.36
3.36
P-1581-WL 8/17.... 6 NAME DATE Warner Linear
NAME DATE
800-825-6544
BEAR LINEAR
1.48 45
BEAR LINEAR
DRAWN NAME TAJ DATE4/22/2014 NAME DATE
BEAR
4/22/2014 LINEAR BEAR LINEAR
DRAWN TAJ 4/22/2014
DRAWN CHECKED TAJ JRZ
4/22/2014
4/22/2014
DRAWN TAJ
TITLE
Performance Graphs
Dimensions
in. mm in. mm in. mm in. mm in. mm in. mm
B-Track
Stroke 4 102 6 152 8 203 10 254 12 305 14 356
K2pl
A 7.03 178.6 9.03 229.4 11.03 280.2 13.03 331.0 15.03 381.8 17.03 432.6
Note: Special lengths available
["A" ±3.18]
B-Track K2pl
"A" ±.125 RETRACTED
NOMINAL STROKE IS .091 [2.31]
[78.23±0.38] LONGER THAN ADVERTISED
3.080±.015 TOLERANCE IS +.036/-.005 [+.91/-.13]
[22.2]
.88 [62.6]
[39.12±0.13] [11.43±0.38]
1.540±.005 (MTG STUD)
[ 0
28.58 -0.08 ] .450±.015 [18.5]
2.46 E
10" [254] LEAD WIRE LENGTH WIRES PROTECTED WITH Ø 2.50 +.01
CONNECT (+) TO GRAY WIRE BLACK SPIRAL WRAP -.05
& (-) TO BLACK WIRE TO EXTEND [31.99]
8 [31.8] 7 THE ACTUATOR
6 5 4 3 2 1.260 1
1.25 PACKARD 56 CONNECTOR
(MTG STUD) [184.76±5.08]
[63.5] 7.274±.200
2.50 4X #10-32 UNF-2B
(MTG STUD) BOLTS FOR MOUNTING
INCLUDES LOCK NUTS ALL DIMENSIONS ARE NOMINAL C
B-Track K2xpl
["A" ±3.18]
"A" ±.125 RETRACTED
NOMINAL STROKE IS .091 [2.31]
LONGER THAN ADVERTISED B
[12.93
12.78 ]
Q.A.
KODIAK ACTUATOR
5.861±.017 THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
BEAR LINEAR. ANY
COMMENTS:
Ø .509 THRU
C K2PL Dimensions
[109.76±0.30] NW
[ ]
WITHOUT THE WRITTEN PERMISSION OF
63.5 +0.3
BEAR LINEAR IS PROHIBITED. SCALE 1:1 SHEET 1 OF 1
8 4.321±.012
7 6 5 .503 4
-1.3 1
8 7 6 5 4 1
B-Track K2js / K2xjs
Jack Stand Actuator DC Motor – Acme or Ball Screw
Features
• Protective coatings and O-ring seals
throughout
• Efficient in-line ball screw system
• Integral load holding brake on K2x model
• Ball detent overload clutch
• Stroke lengths 8 to 16 inches
(200 to 400 millimeters)
• Load capacities up to 2,800 pounds
(12455 N)
• Speeds up to 2.1 inches (53.34
Shown with optional millimeters)/sec. travel
switch box, direct drive
manual override, and • Thermal overload incorporated
footpad. into the motor
• Heavy wall construction
• Double ball bearing motors
Up to 2,800 lbs. (12455 N) Rated Load • Heat treated gears
Up to 2.1 in. (53.34 mm)/sec. Travel Speed • Rugged extension rod bearing support
• Custom mounting options available
The B-Track Jack Stand actuator incorporates a large diameter
extension rod providing the maximum offset load capability within the
Typical Applications
K2 family. The extension rod is slightly smaller than the cover tube and
®
slides on Teflon bearings within the cover tube. This feature makes • Trailer jack stands
the K2js suitable for high-load, free-standing use. • Trailer and vehicle outriggers
• Implement lifts
A number of mounting options are available including trunnion
mounts, or with standard flange plate (as shown). These units can be • Machine height adjustment
customized with an integral switch box, direct drive manual override, or • Camper lifts
pivoting footpad. • Load Levelers
Dimensions
in. mm in. mm in. mm in. mm in. mm
B-Track K2js/
Stroke 8 203 10 254 12 305 14 356 16 406
K2xjs
A 20.98 532.9 22.98 583.7 24.98 634.5 26.98 685.3 28.98 736.1
Note: Special lengths available
["A" ±3.18]
"A" ±.125 RETRACTED
B-Track K2js
NOMINAL STROKE IS .091 [2.31]
LONGER THAN ADVERTISED
[78.23±0.38] TOLERANCE IS +/-.060 [+/-1.52]
3.080±.015 [13.46±0.38]
[19.1] .530±.015
[39.12±0.13] .75
[27.3]
[
50.80 0
+0.30
]
1.540±.005 [14.87±0.56]
[44.22±0.38] 1.08 Ø 2.000 +.012 .585±.022
- .000
1.741±.015
[25.40±0.38]
[148.88±0.43] Ø 1.000±.015
5.861±.017
[109.76±0.30]
[12.93
12.78 ]
4.321±.012 Ø .509
.503 THRU
WIRES PROTECTED WITH
BLACK SPIRAL WRAP
[63.5 +0.3
-1.3 ]
BOTH ENDS Ø 2.50 +.01
- .05
NON-ROTATING ROD
[24.24±0.46]
10" [254] LEAD WIRE LENGTH .954±.018
8 7 6
CONNECT (+) TO GRAY WIRE5 4 3 2 1
& (-) TO BLACK WIRE TO EXTEND [177±5.08]
ALL DIMENSIONS ARE NOMINAL THE ACTUATOR 6.969±.200
UNLESS OTHERWISE SPECIFIED PACKARD 56 CONNECTOR
Measurements in inches, metric in brackets.
B-Track K2xjs
OVER-RIDE MATERIAL
[44.5] PROPRIETARY AND CONFIDENTIAL
MFG APPR.
Q.A.
5.861±.017 7 6
1.75
5 4
[109.76±0.30] [ ]
12.93
12.78
4.321±.012 Ø .509
.503
THRU WIRES PROTECTED WITH
[63.5 +0.3
-1.3 ]
BLACK SPIRAL WRAP +.01
Ø 2.50 -.05
10" [254] LEAD WIRE LENGTH NON-ROTATING ROD
CONNECT (+) TO GRAY WIRE [32.39]
& (-) TO BLACK WIRE TO EXTEND 1.275
THE ACTUATOR [185.03±5.08]
PACKARD 56 CONNECTOR 7.285±.200
ALL DIMENSIONS ARE NOMINAL
UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
Features
• Protective coatings and O-ring seals
throughout
• Efficient in-line load system
• Ball detent overload clutch
• Speeds up to 850 RPM
• Thermal overload incorporated
into the motor
• Heavy wall construction
Optional Configurations • Double ball bearing motors
• Heat treated gears
• Rugged output bearing support
Shown with extended • Customized mounting configurations
gear box screws for
ease of attachment. available
• Optional 24 vdc motor available to
provide more speed selections
20 800 10 800
Amps
Amps
Draw --Amps
Draw --Amps
RPM
RPM
Speed -- RPM
Speed -- RPM
15 700 7.5 700
Current Draw
Current Draw
Speed
Speed
10 600 5 600
Current
Current
5 500 2.5 500
0 400 0 400
0 5 10 15 20 25 30 0 5 10 15 20 25 30
Load in-lbs
Load in-lbs Load
Load in-lbs
in-lbs
K2RAG10-12VDC
Load Capacity 60 in-lbs.Nominal Performance K2RAG10-24VDC Nominal Performance
For Metric Measurements, see page 53.
K2raG10-12VDC Current Draw Speed K2raG10-24VDC Current Draw Speed
400 400
20 10
Amps
Amps
Draw --Amps
Draw --Amps
350 350
RPM
RPM
Speed -- RPM
Speed -- RPM
15 7.5
Current Draw
Current Draw
300 300
Speed
Speed
10 5
Current
Current
250 250
5 2.5
200 200
0 150 0 150
0 10 20 30 40 50 60 0 10 20 30 40 50 60
Load in-lbs
Load in-lbs Load
Load in-lbs
in-lbs
20 200 10 200
Amps
Amps
Draw --Amps
Draw --Amps
RPM
RPM
Speed - RPM
Speed - RPM
15 175 7.5 175
Current Draw
Current Draw
Speed
Speed
10 150 5 150
Current
Current
0 100 0 100
0 20 40 60 80 100 120 0 20 40 60 80 100 120
Load in-lbs
Load in-lbs Load
Load in-lbs
in-lbs
130 130
20 10
Amps
Amps
Draw --Amps
Draw --Amps
110 110
RPM
RPM
Speed - RPM
Speed - RPM
15 7.5
Current Draw
Current Draw
90 90
Speed
Speed
10 5
Current
Current
70 70
5 2.5
50 50
0 30 0 30
0 20 40 60 80 100 120 140 160 180 0 20 40 60 80 100 120 140 160 180
Load in-lbs
Load in-lbs Load
Load in-lbs
in-lbs
20 800 10 800
Amps
Amps
Draw --Amps
Draw --Amps
RPM
RPM
Speed --RPM
Speed --RPM
15 700 7.5 700
Current Draw
Current Draw
Speed
Speed
10 600 5 600
Current
Current
5 500 2.5 500
0 400 0 400
0.0 0.6 1.1 1.7 2.3 2.8 3.4 0.0 0.6 1.1 1.7 2.3 2.8 3.4
Load N-m
Load N-m Load N-m
Load N-m
K2RAG10-12VDC
Load Capacity 6.8 N-mNominal Performance K2RAG10-24VDC Nominal Performance
For Imperial Measurements, see page 52.
K2raG10-12VDC Current Draw Speed K2raG10-24VDC Current Draw Speed
400 400
20 10
Amps
Amps
Draw --Amps
Draw --Amps
350 350
RPM
RPM
Speed -- RPM
Speed -- RPM
15 7.5
Current Draw
Current Draw
300 300
Speed
Speed
10 5
Current
Current
250 250
5 2.5
200 200
0 150 0 150
0.0 1.1 2.3 3.4 4.5 5.7 6.8 0.0 1.1 2.3 3.4 4.5 5.7 6.8
Load N-m
Load N-m Load N-m
Load N-m
20 200 10 200
Amps
Amps
Draw --Amps
Draw --Amps
RPM
RPM
Speed -- RPM
Speed -- RPM
15 175 7.5 175
Current Draw
Current Draw
Speed
Speed
10 150 5 150
Current
Current
0 100 0 100
0.0 2.3 4.5 6.8 9.0 11.3 13.6 0.0 2.3 4.5 6.8 9.0 11.3 13.6
Load N-m
Load N-m Load N-m
Load N-m
130 130
20 10
Amps
Amps
Draw --Amps
Draw --Amps
110 110
RPM
RPM
Speed -- RPM
Speed -- RPM
15 7.5
Current Draw
Current Draw
90 90
Speed
Speed
10 5
Current
Current
70 70
5 2.5
50 50
0 30 0 30
0.0 2.3 4.5 6.8 9.0 11.3 13.6 15.8 18.1 20.3 0.0 2.3 4.5 6.8 9.0 11.3 13.6 15.8 18.1 20.3
Load N-m
Load N-m Load N-m
Load N-m
B-Track K2ra
Dimensions
[99.3]
3.91
Ø .250±.005 [6.35±0.13] THRU [11.1]
.44
[63.5]
2.50 Ø .751 [19.08] 1.000 [25.40]
[ 50.80 +0.30
0 ] [10.9]
(MTG STUD) +.012
Ø 2.000 -.000 [
28.52
0
]
- 0.08
.43 STUD
LENGTH
+.000
PILOT Ø 1.123
-.003
WIRES PROTECTED WITH
[44.5] BLACK SPIRAL WRAP [25.40±0.38]
1.75
(MTG STUD) Ø 1.000±.015
[148.88±0.43]
5.861±.017
[109.76±0.30]
4.321±.012
[63.5 +0.3
-1.3 ] #10-32 STUD
10" [254] LEAD WIRE LENGTH +.01
CONNECT (+) TO GRAY WIRE Ø 2.50 4 PLACES
& (-) TO BLACK WIRE TO EXTEND -.05
THE ACTUATOR
PACKARD 56 CONNECTOR [16.5]
[39.12±0.13] .65
1.540±.005
[169.28]
6.664
[78.23±0.38]
3.080±.015
ALL DIMENSIONS ARE NOMINAL
UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
DRAWN
NAME
TWC
DATE
3/17/2014
BEAR LINEAR
CHECKED TAJ 3/17/2014 TITLE
ENG APPR.
PROPRIETARY AND CONFIDENTIAL MFG APPR. MATERIAL
Q.A.
THE INFORMATION CONTAINED IN THIS K2 ROTARY ACTUATOR
DRAWING IS THE SOLE PROPERTY OF COMMENTS:
BEAR LINEAR. ANY
REPRODUCTION IN PART OR AS A WHOLE SIZE PART NUMBER
WITHOUT THE WRITTEN PERMISSION OF C K2RA Dimensions
BEAR LINEAR IS PROHIBITED. SCALE 1:1.5
8 7 6 5 4 3 2 1
They range from simple to use • Integrated actuator sensors are protected
from the environment
switch box controls for basic extend/
retract function, to state-of-the-art • Solid-state electronic components and
microprocessor based digital electronic non-contact sensors (Hall effect)
controls using SMT design and • Actuator mounted or remote mountable
manufacturing processes.
Easy To Use
• Simple plug-and-play switch box controls are hassle-free – just plug in
Offered functions: and connect the power clips.
• B
asic position controls are integrated with the actuators to simplify
• Basic extend and retract ease of use and maintain the rugged duty capabilities of Warner Linear
actuators. They are easy to use and plug-and-play ready.
• Electric switch and electronic
• Advanced microprocessor based controls are also available. They
stroke limits employ digital electronics using SMT processes and offer a broad
range of intelligent actuator control options. Consult your Warner Linear
• End of stroke outputs technical specialist on how advanced controls might suit your needs.
• Position feedback potentiometer Warner Linear BTc controls are specifically designed for use with the
and encoder outputs B-Track line of actuators. Some controls and options are also suitable for
use with the M-Track models.
• Electronic current limit –
fixed and programmable
• Signal follower
NOTE: All power supply designs are provided with a one foot long cable for connection to
actuator. Accessory cables are available in lengths of 5, 10, 20, 25 foot (1.524, 3.048,
6.096, 7.62mm) length.
Controls
End of Travel Limit Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 61-62
Factory set/not adjustable (P1) . . . . . . . . . . . . . . . . . . . . . Pages 63-64
Field Adjustable (EP1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 65
SBC-DC
Power: Compatible with 12, 24 and 48 volt DC actuators
Function: Extend, Retract, Off via DPDT momentary toggle switch
Enclosure: ABS plastic enclosure 4.7” L x 3.2” W x 2.2” H (119.38mm L x 81.28mm W x 55.88m H)
Input Cable: 12ft. (3.66m), 2 wire, 14AWG cable with alligator clip ends
Output Cable: 1ft. (.30m) cable provided. Designate connector appropriate to actuator being used
Optional extension cables are available in 5-25ft (1.524 - 7.62m) lengths
SBC – DC 3 – 10
SBC-AC
Power: Compatible with 115 or 230 volt VAC input
Function: Extend, Retract, Off via DPDT momentary contact switch
Enclosure: 4.72” L x 4.72” W x 3.15” (119.89mm L x 119.89mm W x 80.01mm H) long dust tight
enclosure
Protection: Externally mounted 5 Amp fuse on outside of enclosure for easy replacement
Input Cable: 6ft. (1.829m) open ended tinned AC input cable provided
Output Cable: Sealed cable gland included for customer supplied output cable
SBC – AC – A
Accessory cables may be ordered in lengths of 5, 10, 20 and 25 feet (1.524, 3.048, 6.096 and 7.62 meters) with the appropriate
connector for the actuator selected. (mini-packard, Packard 56, Weatherpack, Deutsch)
Live Power (LP) cables are required to provide constant power to BTc Limit switch or potentiometer feedback circuits mounted on the
actuator. LP cables provide two connectors.
Signal Cables (SC) provide the LP cable with two additional connectors for use with limit switch or potentiometer feedback.
Output Cable: 1ft. (.30m) length cable with 2-pin Packard 56 (for M-Track 1)
Optional extension cables can be ordered in 5-25ft. (1.524-7.62m) lengths
Operating
Temperature: -30º F to 140º F (-34º C to 60º C)
Ratings: CE, TUV, UL/cUL Conducted EMI meets EN55022 and ROHS
Output Cable: Standard 1 ft. (.30m) cable: specify connector to match actuator:
1. Mini Packard standard for M-Track actuators
2. Packard 56 standard on K2 and K2x model actuators
3. Packard WeatherPack optional on K2 and K2x model actuators
4. Deutsch DT06-2S optional on K2 and K2x model actuators
5. Optional extension output cables can be ordered in 5-25 ft.
(1.524-7.62m) lengths
Live Power
Option: When used with BTc control options (limit switch, potentiometer
feedback) the Live Power option is required. Live power option
provides a constant output power source for external control
components regardless of output power to the actuator. (See
Extension Cable selection to select the correct cable for this option.)
Example:
SBC Model No. Output Power Input Wire Style Live Power
AC Power Supply 24V – 24VDC Blank– 6' (1.829m) Open (3) Strand (Required on P1.2 and
12V – 12VDC (S-Track Wire P2.0 Control Systems)
and I-Track Only) A – 6' (1.829m) Long 3 Prong Blank=No Live Power
Plug (Plug only available on
Input Power 115 VAC input)
AC – 115 VAC input Connector Style:
AC2 – 230 VAC input Switch
(Female Gender) AMP Output
2– Packard 56 (B-Track) S – Rocker Switch
Blank– Standard 12 Amp Output Blank– No Switch
3– WeatherPack (B-Track) H – High Current 20 AMP Output
4– Deutsch DT06-2S (B-Track) (Can run 2 actuators from same
5– S-Track power supply. B-Track Only)
6– I-Track
Any of Warner Linear’s K2 or K2x actuators can be provided with Hall effect or reed switches to be used by the customer
to control actuator start/stopping & positioning. The Hall effect and reed switches are both non-contact, and use a magnet
mounted on the screw inside the actuator tube to activate. Actuators can have 2-4 switches dependent on stroke length.
Hall Effect Switch Part Numbers Available, with K2e or K2xe Note 1: Consult factory for other options if needed
actuator product: Note 2: Units with 3 switches can be no shorter than 4” and
SO2H – 2 end limit switches units with 4 switches can be no shorter than 6”.
SO3W – 2 wheel position switches & home end limit switch
SO3H – 2 end & 1 mid limit switches Reed
SO4W – 2 wheel position switches & 2 end limit switches
SO4H – 2 end & 2 mid limit switches Supply Voltage: Up to 200 VDC max. O switch
Up to 175 VDC max. C switch
Note 1: Consult factory for other options if needed Switching 1.2 Amps max. O switch
Note 2: Units with 3 switches can be no shorter than 4” and Current: 1.5 Amps max. C switch
units with 4 switches can be no shorter than 6”. Contact Rating: 10 Watts max. O switch
5 Watts max. C switch 1K/5K ohm
1K/5K ohm
Lead Wires: 24 AWG
Hall Effect
Operating -40° C to +105° C
Supply Voltage: 4.75 to 24 VDC
Temperature:
Output: Current sinking, max. of 25mA
Housing: Hermetically sealed
Lead Wires: 24 AWG
Operating -40° C to +85° C
Temperature:
SO2O Normally Open Reed
Protection: Reverse polarity protected Adjustable
Switch
Housing: Rugged thermoplastic, sealed
Switch
SO2H Hall Effect Cable
Connector
DT04-3P
Switch Deutsch
Cable
Pin C: Green, Extend Switch Output
Connector
Supply Power Pin B: White, Retract Switch Output
DT06-4S
Deutsch Pin 4: Green, Extended Output, 20mA max. 4.5 to 24VDC Pin A: Black, Switch Inputs
Pin 3: Red, Supply Power 1K/5K ohm
Options
P1.0 Standard Stoke Limit Control
P1.1 Same as P1.0 with two LEDs on the
outside of the control module. LEDs
indicate when end of travel has been
reached.
P1.2 Same as P1.0 with two 12/24 volt,
0.5 Amps outputs that can be used to
signal an external switch, relay, lamp or
PLC input.
P1.2LE Two +5 VDC 25ma outputs plus a
ground to provide a signal when end
of travel is reached. This output can be
The P1.x Limit Switch control provides end of travel used to power LEDs.
positioning through the use of a Hall effect sensor and
motor mounted relay.
Wiring Diagrams
P1 Module
P1.0-DC12/24
Switch Fuse
Connector
Momentary DPDT 24VDC 15A
2-wire, 14awg
Center Off 12VDC 30A
Packard 56
Black
12 or 24VDC
Gray Power Supply
Input
P1 Actuator Extend = Gray +, Black -
Control Actuator Retract = Gray -, Black +
Operation
When the “Customer Supplied Switch” is held in the When the switch is held in the opposite direction so the
direction allowing positive 12 or 24VDC to the gray wire positive lead of the 12 or 24VDC signal is on the black
and 12 or 24VDC ground to the black wire, the actuator wire and the 12 or 24VDC ground is on the gray wire, the
will extend until it reaches the end of stroke. At the end of actuator will retract until it returns to the full home position
stroke, which is determined by the factory set location of which is determined by the factory set location of the
the Hall effect switches inside the actuator cylinder, power second Hall effect switch.
will be removed to the actuator by the P1.0 control. The
actuator will no longer move in that direction even if the If the actuator does not stop when at either end then
customer supplied switch is held. something in the actuator or P1.0 control may be damaged.
Please call the factory for further analysis.
Gray + Ext
Connector Switch Power Supply
Gray + Ret 12 or 24VDC
14-2 AWG Momentary DPDT Input
Black - Packard 56 Center Off + _
Gray
P1.2 Fuse
Control 24VDC 15A
12VDC 30A
Connector
DT04 - 4P
Deutsch
Operation
When the “Customer Supplied Switch” is held in the Apply +12 VDC (for 12VDC unit) or +24 VDC (for @24VDC
direction allowing positive 12 or 24VDC to the gray wire unit) to the red wire of the Deutsch (DT04-4P) 4 pin
and 12 or 24VDC ground to the black wire, the actuator connector and ground to the black wire. This supply needs
will extend until it reaches the end of stroke. At the end of to be the same supply as the actuator and will require less
stroke the “Extend Output” (green wire) will have +12 or 24 than 500mA.
Volts to ground, indicating it is at the end. This signal can When the switch is held in the opposite direction so the
be used to light a Lamp, signal a relay coil, or an isolated positive lead of the 12 or 24VDC signal is on the black
PLC input that only requires 500mA or less. This output wire and the 12 or 24VDC ground is on the gray wire, the
will only be on as long as power is maintained from the actuator will retract until it returns to full home position. At
“Customer Supplied Switch”. the full home position, the “Retract Output” (white wire) will
However, if the output needs to be on even if the have +12 or 24 volts to ground.
“Customer Supplied Switch” is not activated then the “Live CAUTION Do not reverse polarity at live power input
Power input” can be used. This will provide power all the (i.e. 22GA red & black wires) or damage will occur.
time for the output to remain on whenever the Actuator is at
either travel end.
Specifications
Power: 25 Amps max. @ 12 volts
12.5 Amps max. @ 24 volts
Operating
Temperature: -20º F to +150º F (-29º C to 66º C)
Options
EP1.0 Standard Stoke Limit Control
EP1.1 Same as P1.0 with two LEDs on the
outside of the control module. LEDs
indicate when end of travel has been
reached.
EP1.2 Same as P1.0 with two 12/24 volt,
0.5 Amps outputs that can be used to
signal an external switch, relay, lamp or
PLC input.
EP1.2LE Two +5 VDC 25ma outputs plus a
ground to provide a signal when end
of travel is reached. This output can be
The EP1.x Limit Switch control provides end of travel
used to power LEDs.
positioning through the use of a magnetic switch and
EP1.4 Same as P1.0, end limit stopping with
motor mounted relay.
0-10K ohm potentiometer output.
The EP1 limit switches are mounted in a channel on the
EP1.5 End limit stopping with end limit outputs
actuator cover tube accessible below a durable cover. and 0-10K potentiometer outputs.
(For factory set limit switches see P1.0 designs). The EP1
switches are field adjustable.
Scan to watch!
The Electronic Stroke control package consists of the How to Adjust the Limit Switches for a K2 or
magnetic sensors and a motor mounted relay within an K2X Actuator with External or EP Limit Switches
https://p.widencdn.net/imzc9v
enclosure suited for harsh environments.
A Zener diode suppression is used on both input and
outputs for added protection from electrical spikes.
Unit reversing is achieved by reversing input power polarity
to the motor.
ø 2.62 (66.55)
2.13 (54.10)
ADDED TO
MOTOR LENGTH
9.10 (231.14)
The PQS is a bi-directional current limit control. The control ø 2.62 (66.55)
monitors current during actuator motion and quickly
stops the actuator if an object gets in the way or at the
end of stroke. The actuator will remain off until power is 2.13 (54.10)
reapplied. The current limit setting is adjustable with two ADDED TO
potentiometers that are accessible through two plugged MOTOR LENGTH
holes on the side of the housing. 9.10 (231.14)
Features
Quick Stop: Field adjustable potentiometers limit the amount
of current through the motor in one or both directions. Both Adjusting Extend &/or Retract Trip Current
potentiometers are factory set to the maximum actuator • Remove access plugs on the side of control.
current unless otherwise specified. Potentiometers field
adjustable also. • Rotate trim pot counter clockwise for min. load.
Motor Power: Switched by on board relay. The relay allows • Rotate trim pot clockwise for max. load.
power to the motor as long as the actuator is not being • Adjust the Retract pot to control closing force.
commanded to go past the end limits.
• Adjust the extend pot to control lifting force.
Faster Stopping: Electronic dynamic braking, (EDB) is applied
• Adjust as viewed with
after every move for more accurate and faster stops.
extension rod pointing up. LOAD
Load Limit Trip Outputs: These outputs indicate when the
• Reinstall access plugs.
current limit has been exceeded in either direction. They are
active low transistor outputs. - +
RETRACTED EXTENDED
Enclosure: Attaches to back of motor or other surface and is FORCE FORCE
potted to work in harsh environments. ADJUST ADJUST
Protection: Zener diode suppression on the input and output
for extra protection in noisy environments.
PQS-12V/24V Module
Switch Fuse
Connector Momentary DPDT 24VDC 15A
2-wire, 14awg Center Off 12VDC 30A
Packard 56
Black
+ 12 or 24VDC
Gray Power Supply
PQS.2-12V/24V Module
Switch Fuse
Connector Momentary DPDT 24VDC 15A
2-wire, 14awg Center Off 12VDC 30A
Packard 56
Black
+
12 or 24VDC
Gray Power Supply
PQS – Input
Control
Connector Extend Lamp
DT04-4P Relay, or isolated
Deutsch Pin 4: Green, Extend Load Limit Trip Output, 150mA max. – PLC input +
Pin 3: Red, Supply Power + (12VDC or 24VDC)
Pin 2: White, Retract Load Limit Trip Output, 150mA max.
Extend Lamp
Pin 1: Black, Supply Power Ground – Relay, or isolated +
PLC input
Load Limit Trip Output Wiring
-outputs are active low
All dashed lines are customer supplied connections
Live power is needed to maintain the 0-10VDC analog output 9.10 (231.14)
signal even when the “Customer Supplied Switch” is not
activated. This feature has to be connected to ensure position
is saved. The power has to be the same as the switched
power supplied to the actuator and requires less than 100mA.
Switch Power Supply
Connector
12 or 24VDC
14-2 AWG Momentary DPDT Input
Black - Packard 56 Center Off + _
Wiring Diagram
P2 Module Gray +
Gray + Ext Fuse
P2.0-DC12/24 P2 Gray - Ret 24VDC 15A
Control All dashed lines are customer 12VDC 30A
supplied connections
Connector
DT04-6P Pin 6 Orange 0 - 10V
Deutsch
Isolated PLC Input
Pin 5 Blue +0 - 1V Or Other Device
Model Selection
Maximum
Input Voltage Output Current
Model No. (vdc) (Amps) Features
P2.0 (DC12) 12 25 Base = Electronic Stroke Limits with 0 to + 10V Analog Output and EDB
P2.0 (DC24) 24 12.5 Base = Electronic Stroke Limits with 0 to + 10V Analog Output and EDB
Typical Wiring
All dashed lines are customer supplied connections Actuator Extend = Orange +12VDC
Actuator Retract = Green +12VDC
Control Operation
Apply 12 VDC to the main power input. Use the same 12 The auxiliary power output is used to power additional
VDC supply to apply positive voltage to the orange wire to 12VDC items as needed. The power is the same as the
extend the actuator rod. When done extending, remove the “Main Power Input” applied by the customer to the 2-pin
positive 12 VDC from the orange wire and apply to the green Packard 56 connector. The total power available is based
wire to retract the actuator. on the customer supplied Power Input provided. The fuse
should then be sized to 135% of the total power needed.
Specifications
Power: 12/24 VDC
Maximum
Current: 20 Amps single, 10 Amps dual
Operating
Temperature: -20º F to +150º F (-28º C to 66º C)
Operating
Frequency: 915 MHz
Enclosure: IP67
Replaceable CR2032, life expectancy dependent on
Remote Battery: use, but should last approx. 2 years
Models Available
SBC-S12V-WR: 20 Amp, Single Output
Typical Wiring
Fuse
Connector 24VDC 15A
2-wire, 14awg 12VDC 30A
Packard 56
Black
Power Supply
Gray
Input
Warner Linear actuators are quickly and easily mounted Scan to watch!
by slipping pins through the holes at each end of the unit Proper Steps and Best Practices for Mounting
and into the brackets on the machine frame and load to be of Warner Linear Actuators Video
https://p.widencdn.net/k3etry
moved.
X Right Wrong
Actuator
Axis
Mounting pins must be parallel to each other as shown Loads should act along the axis of the actuator.
above. Pins which are not parallel can cause excess Off-center loads may cause binding and lead to
vibration or actuator binding. premature unit failure.
Cantilever
Yoke Mount Mount
Right Wrong
Ensure that mounting pins are supported at both ends. Do not attempt to mount M-Track actuators by the cover
Cantilevered mounting is unacceptable. Failure to provide tube. The tube is not designed to support the forces
proper support will shorten unit life. required for tube mounting.
Axial load
A load along the axis of the actuator screw (see figure 1).
Back drive
Force applied on a ball bearing nut that causes rotational torque to reverse
Figure 1 Axial load direction. A force sufficient to cause a unit to change direction.
BTc
B-Track control family.
Cantilevered mount
A mounting where the mounting pin is not supported on both sides. Cantilevered
mounts are common causes of failure (see figure 2).
Clevis mount
A U-shaped metal piece that has the ends drilled to accept a pin or bolt
(see figure 3).
Figure 2 Cantilevered mount
Compression load
Compression loading will press on the unit (see figure 4).
Cover tube
The outer tube or cover that encloses the screw and extension tube for an
actuator.
Figure 3 Clevis mount
Current vs. load
The load on the motor is measured by amperes (current). Current draw will
increase as load increases.
COMPRESSION
LOAD
Cycle
Movement from a fully retracted to fully extended position and back to fully
retracted.
Duty cycle
The amount of ‘on-time’ vs total time. A 25% duty cycle means that a unit
operates for 10 seconds out of 40 seconds, or 4 seconds out of 16 seconds.
Extension rate
The rate of speed at which the actuator extends or retracts. This will vary based
on loading (impact of load on speed is greater on DC units than on AC units).
ESL
Electronic Stroke Limit magnetically activated Hall effect switches that turn power
off at end of stroke.
Extended length
X
The overall length of the actuator from the center of the rear clevis to the center
of the extension tube pin hole when the unit is at full extension (see figure 6).
Load
X
The force, measured in pounds, that is applied as an axial load on the actuator.
Figure 7 Pin mount
Load holding
The ability of the actuator to hold a load stationary when power is off.
Peak load
The maximum dynamic load that will be applied to the actuator, or that the
actuator is capable of moving.
Radial load
A load applied to the side of the extension tube or across the body of the actuator.
Normally radial loading will have a negative impact on unit life (see figure 8).
Restraining torque
The torque required to prevent torque within the unit from causing rotation on the Figure 9 Restraining torque
body or extension tube of the unit (see figure 9).
Retracted length
The overall length of the actuator from the center of the rear clevis to the center of
the extension tube pin hole when the unit is at full retracted position (see figure 10).
Side load
See radial loading (see figure 8).
Figure 10 Retracted length
Static load
The maximum non-operating (or non-moving) load. Static load is the load holding
capability of an actuator.
Synchronous position
Having more than one actuator extend and retract together maintaining ± 0.20
position relative to each other.
Tension load
A load that will tend to pull on the unit (see figure 11).
TENSION
LOAD
Thermal overload
A switch within the motor that will open if the motor exceeds a predetermined
heat level.
Figure 11 Tension load
Title Phone ( )
Project Specifications
Load Movement_________________________________
In dumping applications, when load first acts to compress
_________________________________ screw and then to retract screw (or vice versa)
_________________________________
Gearbox Mount_________________________________
_________________________________ Input Voltage______________________________________
_________________________________
San Marcos, TX - USA New Hartford, CT - USA Nuttall Gear and Warren, MI - USA
1 -800-458-0887 1-800-800-6445 Delroyd Worm Gear 1-800-348-0881– Press #1
For application assistance:
Universal Joints, Drive Shafts, Worm Gear and
Matrix International 1-800-348-0881 – Press #2
Mill Gear Couplings Helical Speed Reducers
Electromagnetic Clutches Niagara Falls, NY - USA
Erie, PA - USA and Brakes, Pressure Operated Marland Clutch
1-920-593-2444 Clutches and Brakes
1-716-298-4100
Roller Ramp and Sprag Type
Brechin, Scotland Overrunning Clutches
Heavy Duty and Backstops
Bibby Turboflex +44 (0) 1356 602000 Clutches and Brakes
Disc, Gear, Grid Couplings, New Hartford, CT - USA South Beloit, IL - USA
Overload Clutches Industrial Clutch 1-800-216-3515
1-800-825-6544
Dewsbury, England Pneumatic and Oil Immersed
+44 (0) 1924 460801 Clutches and Brakes Stieber Clutch
Warner Electric
Boksburg, South Africa Waukesha, WI - USA Overrunning Clutches
Electromagnetic Clutches
+27(0) 11 918 4270 and Brakes 1-262-547-3357 and Holdbacks
www.warnerlinear.com
31 Industrial Park Road 7, rue Champfleur, B.P. 20095
New Hartford, CT 06057 - USA St. Barthelemy d'Anjou - France
815-389-3771 +33 (0) 2 41 21 24 24
Fax: 815-389-2582 Fax: +33 (0) 2 41 21 24 70 P-1581-WL 8/17