mV transmitter
2261
– Load cell amplifier
– mV to current / voltage conversion
– Front-programmable / LED display
– Relative calibration of input span
– NPN / PNP input for external taring
– Supply for standard transducers
Advanced features
Applications
• A multifunction user interface consisting of three pushbuttons and
a 3-digit LED display for programming.
Application
• The 2261 converts bipolar mV signals from transducers supplied
directly by the device to standard current / voltage signals.
• The 2261 is suitable for load cell application as well as other
applications such as tank filling and draining, weighing with a
taring function, measurement of cable tensile force, level control,
signal conversion / amplification etc.
Technical characteristics
• Front error LED.
• The analog input can be programmed for voltage in the range -
40...100 mVDC.
• The digital signal can be selected as either NPN or PNP.
• Taring can either be by way of the digital input or from the front
interface.
• The analog output can be programmed to current in the range
0...20 mA or voltage in the range 0...10 VDC.
• Transducer supply which can be programmed to 5...13 VDC from
the front. It is up to the customer to ensure a max. load of 230 mA
(e.g. 6 parallel 350 Ω load cells).
• Sense input (with transducer supply used) for compensation for
cable resistance to the transducer.
• Mounting for a standard 11-pole socket which can be adapted for
DIN rail or plate use with PR’s 7023 adaptor and 7024 mounting
keying.
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions Output specifications
Operating temperature................................... -20°C to +60°C Current output
Calibration temperature................................. 20...28°C Signal range................................................... 0...20 mA
Relative humidity............................................ < 95% RH (non-cond.) Min. signal range............................................ 5 mA
Protection degree........................................... IP50 Load (@ current output)................................. ≤ 600 Ω
Load stability.................................................. ≤ 0.01% of span / 100 Ω
Mechanical specifications Current limit.................................................... < 23 mA
Dimensions (HxWxD)..................................... 80.5 x 35.5 x 84.5 mm (D is
without pins) Voltage output through internal
Weight approx................................................ 130 g shunt.............................................................. See manual for details
of span........................................................... = of the presently selected
Common specifications range
Supply
Observed authority requirements
Supply voltage............................................... 19.2...28.8 VDC
EMC............................................................... 2014/30/EU
Max. required power...................................... 7.2 W
RoHS.............................................................. 2011/65/EU
Internal power dissipation.............................. 2.2 W
EAC................................................................ TR-CU 020/2011
Response time
Response time (programmable).................... 0.06...999 s
Signal / noise ratio......................................... Min. 60 dB
Updating time................................................. 20 ms
Signal dynamics, input................................... 17 bit
Signal dynamics, output................................. 16 bit
Effect of supply voltage change..................... < ±0.002% of span / %V
Temperature coefficient................................. < ±0.01% of span / °C
Linearity error................................................. < 0.1% of span
Auxiliary voltage: Transducer
supply............................................................. 5...13 VDC
Load (max.).................................................... 230 mA
EMC immunity influence................................ < ±0.5% of span
Input specifications
Common input specifications
Max. offset...................................................... 70% of selec. max. value
Voltage input
Measurement range....................................... -40...100 mV
Min. measurement range (span).................... 10 mV
Input resistance.............................................. > 10 MΩ
Overrange...................................................... 0...999% of selected
measurement range
NPN, digital input........................................... Pull up 24 VDC / 6.9 mA
PNP, digital input........................................... Pull down 0 VDC / 6.9 mA
Trig level low, NPN/PNP................................ < 6 VDC
Trig level high, NPN/PNP............................... > 10.5 VDC
Pulse length................................................... > 30 ms
2261-022525