3-color display
Digital Flow Switch for Water
                                      Series PF3W
                                                                                                                                                                                            ®
                                                                                                                                                                                 RoHS
                                                                           How to Order
                Remote sensor unit Output specification/Temperature sensor                                                          Remote sensor unit/Unit printed on label
                                               OUT1                     OUT2                Temperature                              Symbol Instantaneous flow rate Temperature
                                  Symbol
 For how to order of                         Flow rate               Temperature              sensor                                   Nil        L/min                oC
 remote monitor unit,               1     Analog 1 to 5 V                 —                                                                       L/min
                                                                                                None                                   G                             oC/oF
 refer to page 18.                  2    Analog 4 to 20 mA                —                                                                    (gal/min)
                                   1T     Analog 1 to 5 V           Analog 1 to 5 V      With temperature sensor                     Under the New Measurement Law, units other
                                   To use in combination with remote monitor (PF3W3 series),                                         than SI (symbol “Nil”) cannot be used in Japan.
                                   select analog output of 1 to 5 V of flow rate (output symbol                                     Note) G: Made to Order
                                   “-1” or “-1T”).                                                                                     Reference: 1 [L/min]        0.2642 [gal/min]
                                  Note) Analog output of 4 to 20 mA with temperature sensor is                                                     1 [gal/min]       3.785 [L/min]
                                        made to order. (Refer to page 10.)                                                                         oF = 9/5oC + 32
          Remote
        sensor unit                PF3W 5 04                                              03 1T
        Integrated
          display                  PF3W 7 04                                              03 AT                              M
                                                Type
                                 5 Remote sensor unit                                                                                                       Made to Order
                                 7 Integrated display                                 Thread type                                                          X109 Seal material EPDM
                                                                                       Nil    Rc                                                           X128 Analog 4 to 20 mA 2 output type Note)
                           Rated flow range (Flow range)                                N    NPT                                                           X143 Piping material brass
                                  Symbol Rated flow range                               F    G                                                           Note) Applicable only for remote type with
                                   04     0.5 to 4 L/min                              ISO228 equivalent                                                        temperature sensor (Refer to page 10.)
                                   20     2 to 16 L/min                                          Port size                                            Calibration certificate (Only flow sensor)
                                   40     5 to 40 L/min                  Port   Rated flow range                                                        Nil                  None
                                   11 10 to 100 L/min             Symbol
                                                                         size 04 20 40 11 21                                                             A         With calibration certificate
                                   21 50 to 250 L/min              03    3/8  $ $ — — —                                                               The certificate is written in both English and
                  Flow adjustment valve                            04    1/2  — $ $ — —                                                               Japanese. Integrated display type with
          With/without flow  Rated flow range                      06    3/4  — — $ $ —                                                               temperature sensor can only display flow rate.
Symbol                                                             10    1/1  — — — $ —
          adjustment valve 04 20 40 11 21                                                                                          Bracket (Option)
    Nil       None          $ $ $ $ $                              12 1 1/4 — — — — $                                                Nil                                None
    S          Yes          $ $ $ — —                              14 1 1/2 — — — — $                                                                                  Bracket
Note 1) 100 and 250 L/min types with flow adjustment
         valves are not available.                      Integrated display Output specification/Temperature sensor
Note 2) The flow adjustment                                                                                                           R
                                         OUT1                             OUT2                        Temperature
         valve of this product is Symbol                                                                  sensor
                                         Flow rate       Flow rate                  Temperature
         not suitable for
                                    A     NPN               NPN                           —
         applications which
         require constant           B     PNP               PNP                           —                                     Note) With bracket is not available for 250
         adjustment of flow rate.   C     NPN         Analog 1 to 5 V                     —                                           L/min type.
                                    D     NPN      Analog 4 to 20 mA                      —
                                                                                                          None             Integrated display/Unit specification
Note 1) External input: The         E     PNP         Analog 1 to 5 V                     —
        accumulated value, peak                                                                                          Symbol Instantaneous flow rate Accumulated flow Temperature
                                    F     PNP      Analog 4 to 20 mA                      —
        value, and bottom value                                                                                            M         L/min                    L            oC
                                    G     NPN      External input Note 1)                 —
        can be reset.                                                                                                      G       gal/min                   gal           oC
                                    H     PNP      External input Note 1)                 —
Note 2) For units with                                                     Note 2)                                         F       gal/min                   gal            oF
                                   AT     NPN              (NPN)                         NPN
        temperature sensor,                                                Note 2)                                         J         L/min                    L             oF
        OUT2 can be set as         BT PNP                  (PNP)                         PNP
                                                                                                           With
                                                     (Analog 1 to 5 V) Note 2) Analog 1 to 5 V                            Under the New Measurement Law, units other
        either temperature output CT NPN                                                              temperature
                                                                           Note 2)                                        than SI (symbol “M”) cannot be used in Japan.
        or flow rate output.       DT NPN           (Analog 4 to 20 mA)            Analog 4 to 20 mA
                                                                                                         sensor          Note) G, F, J: Made to Order
        Setting when shipped is    ET PNP            (Analog 1 to 5 V) Note 2) Analog 1 to 5 V
                                                                           Note 2)
                                                                                                                            Reference: 1 [L/min]    0.2642 [gal/min]
        for temperature output.    FT PNP           (Analog 4 to 20 mA)            Analog 4 to 20 mA                                    1 [gal/min]   3.785 [L/min]
                                                                                                                                        oF = 9/5oC + 32
Options/Part No.                                                                                                     Lead wire
When optional parts are required separately, use the following part numbers to place an order.                                 Nil                                                 N
                                                                                                                     With lead wire with M8                    Without lead wire
      Description         Part no.    Qty.                           Note
                                                                                                                     connector                                 with M8
                            ZS-40-K    1      For PF3W704/720/504/520 With 4 tapping screws (3 x 8)                  (3 m)                                     connector
     Bracket Note)          ZS-40-L    1          For PF3W740/540       With 4 tapping screws (3 x 8)
                            ZS-40-M    1          For PF3W711/511       With 4 tapping screws (4 x 10)
Lead wire with M8 connector ZS-40-A    1                    Lead wire length (3 m)
Note) For units with flow adjustment valve, 2 brackets are required.
1