MFP TB 1599R2
MFP TB 1599R2
: CCE-1764R
Technical Report
MFP-TB-1599R2
Correction and addition of the modification items in ” ROM UPGRADE..... (9) ~ (10)”
announced in MFP-TB-1599R issued on May 22nd, 2017
Caution for firmware upgrade: Make sure to turn off the main power once. Then turn on the power
and upgrade the firmware.
- If the firmware update procedure is executed while MFP is still operating, the operation panel
becomes black after the firmware upgrade and MFP may not be able to start up in some rare cases.
- If upgrading from the version older than 04.01.Z1.00, 04.01.K1.00 you won’t be able to
restore original version.
- If "Google drive" is used with the version older than 04.01.Z1.00, 04.01.K1.00 it will no
longer be used after firmware upgrade.
In that case, go into System Settings > Cloud Connect Settings and enable "Google
drive" for usage.
Desti- ROM
Model control BUNDLE ICU ASIC PCU SCU SPF E-Manual
nation No.
MX-3050N
MX-3550N
0601K100_
MX-4050N 0600K100 0600Z100 0601Z100 0500Z100 - 0240K100
17051000
MX-5050N
MX-6050N Except
MX-3060N for
MX-3560N Taiwan, F01 -
MX-4060N South
MX-3070N Africa 0601Z100_
0600Z100 0600Z100 0601Z100 0500Z100 0240Z100
MX-3570N 17051000
MX-4070N 0500Z100
MX-5070N
MX-6070N
Item of change 㸸
Correction of H3-02 (Fusing section high temperature trouble (Upper sub)(TH_US1))
Main unit
1 which may occur on the low speed model
control
(MX-3050N/3550N/4050N/3060N/3560N/4060N/3070N/3570N/4070N)
Upgrade of ICU,ASIC,PCU,SCU,SPF-ROM, E-Manual 㺃㺃㺃(9)
From May 2017 production
Desti- ROM
Model control BUNDLE ICU ASIC PCU SCU SPF E-Manual
nation No.
MX-3050N
MX-3550N
0600K100_
MX-4050N 0600K100 0600Z100 0600Z100 0500Z100 - 0240K100
17041700
MX-5050N
MX-6050N Except
MX-3060N for
MX-3560N Taiwan, F00 -
MX-4060N South
MX-3070N Africa 0600Z100_
0600Z100 0600Z100 0600Z100 0500Z100 0240Z100
MX-3570N 17041700
MX-4070N 0500Z100
MX-5070N
MX-6070N
Item of change 㸸See the separate page
ROM Version Combination History Table
Model : MX-3050N/3550N/4050N/5050N/6050N
ROM
No. Destination Control BUNDLE ICU ASIC PCU SCU FAX E-Manual Action T/R No
No.
0513K100_ 2017/1
(8) E03 0512K100 0510Z100 0501Z100 0400Z100 - 0230K100 CCE-1697
16122000 Mid
0512K100_ 2016/12
(7) E02 0511K100 0510Z100 0501Z100 0400Z100 - 0230K100 CCE-1685
16112900 Mid
0511K100_
(6) ALL E01 0511K100 0510Z100 0500Z100 0400Z100 - 0230K100
16111601 2016/11 CCE-
0510K100_ Mid 1666R
(5) E00 0510K100 0510Z100 0500Z100 0400Z100 - 0230K100
16110700
0400K100_
(3) D00 0101Z100 0400Z100 0400Z100 0300Z100 - 0220K100 2016/6 CCE-1605
16061400
North
B01
America
0201K100_ 2016/2
(2) Except for 0201Z100 0200Z100 0200Z100 0201K100 0100Z100 0130K100 CCE-1515
16011400 Mid
North A01
America
0200Z100_ 2015/12
(1) ALL B00 0200K100 0200Z100 0200Z100 0200Z100 0100Z100 0130K100 CCE-1507
15121800 Mid
Model : MX-3060N/3560N/4060N
ROM
No. Control BUNDLE ICU ASIC PCU SCU SPF E-Manual Action T/R No
No.
0513Z100_ 2017/1
(8) E03 0512Z100 0510Z100 0501Z100 0400Z100 - 0230Z100 CCE-1697
16122000 Mid
0512Z100_ 2016/12
(7) E02 0511Z100 0510Z100 0501Z100 0400Z100 - 0230Z100 CCE-1685
16112900 Mid
0511Z100_
(6) E01 0511Z100 0510Z100 0500Z100 0400Z100 - 0230Z100
16111601 2016/11 CCE-
0510Z100_ Mid 1666R
(5) E00 0510Z100 0510Z100 0500Z100 0400Z100 - 0230Z100
16110700
0400Z100_
(3) D00 0101Z100 0400Z100 0400Z100 0300Z100 0300Z100 0220Z100 2016/6 CCE-1605
16061400
0201Z100_ 2016/2
(2) B01 0201Z100 0201Z100 0200Z100 0200Z100 0100Z10a 0150Z100 CCE-1515
16011400 Mid
0200Z100_ 2015/12
(1) B00 0200Z100 0200Z100 0200Z100 0100Z10a 0101Z100 0150Z100 CCE-1507
15121800 Mid
Model : MX-3070N/3570N/4070N/5070N/6070N
ROM
No. Control BUNDLE ICU ASIC PCU SCU SPF E-Manual Action T/R No
No.
0513Z100_ 2017/1
(8) E03 0512Z100 0510Z100 0501Z100 0400Z100 0400Z100 0230Z100 CCE-1697
16122000 Mid
0512Z100_ 2016/12
(7) E02 0511Z100 0510Z100 0501Z100 0400Z100 0400Z100 0230Z100 CCE-1685
16112900 Mid
0511Z100_
(6) E01 0511Z100 0510Z100 0500Z100 0400Z100 0400Z100 0230Z100
16111601 2016/11 CCE-
0510Z100_ Mid 1666R
(5) E00 0510Z100 0510Z100 0500Z100 0400Z100 0400Z100 0230Z100
16110700
0401Z100_ 2016/8 CCE-
(4) D01 0401Z100 0400Z100 0401Z100 0300Z100 0300Z100 0220Z100
16080400 Mid 1634R2
0400Z100_
(3) D00 0101Z100 0400Z100 0400Z100 0300Z100 0300Z100 0220Z100 2016/6 CCE-1605
16061400
0201Z100_ 2016/2
(2) B01 0201Z100 0201Z100 0200Z100 0200Z100 0100Z10a 0150Z100 CCE-1515
16011400 Mid
0200Z100_ 2015/12
(1) B00 0200Z100 0200Z100 0200Z100 0100Z10a 0101Z100 0150Z100 CCE-1507
15121800 Mid
䛆Description䛇 䕿䠙applied
Model
MX-3060N
MX-3560N
MX-3050N
No. Item Description MX-4060N MX-5050N MX-5070N
MX-3550N
MX-3070N MX-6050N MX-6070N
MX-4050N
MX-3570N
MX-4070N
Implementation of following features to erase cache information on
authentication for cloud connection in User Control -> User List
Main unit
1 䕿 䕿 䕿 䕿
control
- Delete Your Information for External Connect
- Delete All Information for External Connect
Addition of a mode which shows toner quantity in MIB until it turns “Empty”
using values while toner quantity is “Low”
Main unit SIM26-69 H (MIB TONER LOW INDIXATION)
2 䕿 䕿 䕿 䕿
control 0: Retrieves information on toner quantity with value (Default)
1. Retrieves “Low” status (-3)
* “Toner Low” is not indicated with default condition.
Implementation of a Soft SW which turns on/off the confirmation message
displayed when Blank Page Skip feature is enabled.
SIM55-3 SW No.44
Main unit
3 Data 2 (Copy) 䕿 䕿 䕿 䕿
control
Data 3 (Image Send)
0: Display (Default)
1: Do not display
Main unit Implementation of an error lamp setting in Device Settings with selections of
4 䕿 䕿 䕿 䕿
control “Not Use”, “Blink Only” and “Light & Blink”
Main unit Implementation of selection whether to execute auto registration of user
5 䕿 䕿 䕿 䕿
control information in “User Control” -> “Default Settings” on main unit
Changing authentication setting for home directory during user registration
Main unit
6 from “Use Login Name And Password for User Authentication” to “Use Login 䕿 䕿 䕿 䕿
control
Name for User Authentication”
Modification of behavior during Toner near end status as follows:
- The alert on toner low is notified via E-RIC when an e-mail address is
entered or “Toner Low” is selected on management web page. This won’t be
Main unit
7 affected whether SIM26-69 is set to A or C. 䕿 䕿 䕿 䕿
control
SIM26-69 (Operating condition during toner near end)
A: Whether to display a message to prompt preparation of toner
C: Whether to display a message to notify toner near end
Main unit Correction of problem with touch panel which does not work in low
8 䕿 䕿 䕿 䕿
control temperature environment
Main unit
9 Correction of failure to reboot MFP after firmware update 䕿 䕿 䕿 䕿
control
Main unit Collecting all log data in one folder in thumb drive when SIM56-99 (batch log
10 䕿 䕿 䕿 䕿
control data collection) is executed.
Correction of machine lockup which may occur when authentication using
Main unit
11 an IC card is executed while primarily requesting the authentication to an 䕿 䕿 䕿 䕿
control
authentication server
Main unit Correction of machine lockup which occurs while searching an address in
12 䕿 䕿 䕿 䕿
control the Address Book
Correction of failure with keyboard
Main unit
13 The operating “CAPS” key on software keyboard turns on the Num Lock on 䕿 䕿 䕿 䕿
control
external keyboard being connected, illuminating the LED.
Main unit
14 Correction of recording unnecessary logs in Active Directory environment 䕿 䕿 䕿 䕿
control
Main unit Correction of MPF reboot after execution of User Control -> User Count ->
15 䕿 䕿 䕿 䕿
control Save User Count -> Print and Delete the Data
䛆Description䛇 䕿䠙applied
Model
MX-3060N
MX-3560N
MX-3050N
No. Item Description MX-4060N MX-5050N MX-5070N
MX-3550N
MX-3070N MX-6050N MX-6070N
MX-4050N
MX-3570N
MX-4070N
Main unit Correction of fuser motor keeps running with low speed after opening Right
16 䕿 䕿 䕿 䕿
control cover
Main unit
17 Modification of software control to prevent H3 trouble due to overshoot. 䕿 䕿 䕿 䕿
control
Correction of F1-00 error (Communication error between Finisher and PCU
Main unit PWB)
18 䕿 䕿 䕿 䕿
control This error may occur when a staple job is immediately followed by a non-
staple job.
Main unit
19 Modification of failure to clinch staple properly 䕿 䕿 䕿 䕿
control
Fusing belt unit for MX-5050N/5070N/6050N/6070N series was
changed from May 2017 production. For the purpose to avoid the
low temperature offset, the fusing temperature control function has
been added to Soft SW and the default value has been changed.
For machines before May 2017 production, the modification has
been made so that the set value does not automatically change
even when updating the firmware to this version.
If the set value is manually changed from 0 to 1, the high
temperature offset may occur.
In addition, if the setting of Soft SW is changed from 0 to 1 while the
fusing belt unit before May 2017 production is installed, the high
temperature offset may occur.
*Changed fusing unit is supplied as the service parts. This will be
announced on Service Information later.
Main unit
20 NA NA 䕿 䕿
control
SIM55-1 SW No.22 Data 8
MX-5150FN/6150FN/5170FN/6170FN series
0: Not control the temperature
1: Control the temperature (Default)
MX-
3050N/3550N/4050N/3060N/3560N/4060N/3070N/3570N/4070N
series
0: Not control the temperature
1: Not control the temperature (Default)