4. Slide Blower onto PVC Pipe. Lower until the stop WARNING : RISK OF ELECTRIC SHOCK - Install at least 5 feet (1.5 m) from tub water
tabs make contact with the PVC pipe. using nonmetallic plumbing. Install blower no less than 1 foot (305 mm) above the maximum water level
or with an approved Hartford loop configuration as outlined in section 2 “Plumbing” to prevent water from
5. Blower should be installed vertically, away from contacting electrical equipment. Install in accordance with the installation instructions.
direct sunlight. To minimize the risk of severe injury or death the To Reduce the Risk of Injury -
6. Do not glue or otherwise permanently attach the appliance should not be subjected to the piping a) The water in a spa should never exceed 104°F
system pressurization test. Local codes may (40°C). Water temperatures between 100°F (38°C)
blower to plumbing. 2" PVC require the pool piping system to be subjected to a and 104°F (40°C) are considered safe for a healthy
7. Do not remove the blower check valve diaphragm. pressure test. These requirements are generally not adult. Lower water temperatures are recommended
intended to apply to the pool equipment. Zodiac® for young children and when spa use exceeds 10
8. Drill two (2) 1/8" pilot holes through the textured fastener safe area pool equipment is pressure tested at the factory. minutes.
marked on the blower body. The holes should be drilled through the blower However, if the WARNING cannot be followed and
b) Since excessive water temperatures have a high
body and PVC pipe. The holes should be oriented 180° pressure testing of the piping system must include
potential for causing fetal damage during the early
the appliance, BE SURE TO COMPLY WITH THE
from one another. FOLLOWING SAFETY INSTRUCTIONS:
months of pregnancy, pregnant or possibly preg-
WARNING nant women should limit spa water temperatures to
9. Install one (1) 1/2” 8-18 thread forming screw into - Check all clamps, bolts, lids, lock rings and
100°F (38°C).
each of the previously drilled pilot holes. The screws and Do not use chemical adhesives to system accessories to ensure they are properly
installed and secured before testing. c) Before entering a spa or hot tub, the user should
pipe should not interfere with the normal travel of the affix the blower to the air inlet line.
Fumes from chemical adhesives - RELEASE ALL AIR in the system before testing measure the water temperature with an accurate
check valve diaphragm. - Test water pressure must NOT EXCEED 35 PSI. thermometer since the tolerance of water tempera-
may accumulate in the piping and ture-regulating devices varies.
- Water temperature for test must NOT EXCEED
10. The blower also comes equipped with a mounting explode causing property damage,
100°F (38°C). d) The use of alcohol, drugs, or medication before
bracket which can be used to secure the blower to a serious injury or death. Limit test to 24 hours. After test, visually check or during spa or hot tub use may lead to uncon-
vertical surface system to be sure it is ready for operation. sciousness with the possibility of drowning and can
such as a wall or NOTICE: these parameters apply to Zodiac greatly increase the risk of fatal hyperthermia.
post. Flat equipment only. For non-Zodiac equipment, consult e) Obese persons and persons with a history of
equipment manufacturer. heart disease, low or high blood pressure, circula-
11. If not used Installation must be done in accordance with the tory system problems, or diabetes should consult a
the bracket can National Electrical Code (“NEC ” or NFPA-70 )
® ® ®
physician before using a spa.
be removed and Diaphragm in the US, the Canadian Electrical Code (“CEC” or
f) Persons using medication should consult a
stored. C22.1) in Canada, and/or any other local and national
physician before using a spa or hot tub since some
installation codes.
Stop Tabs medication may induce drowsiness while other
RISK OF ELECTRIC SHOCK, FIRE, PERSONAL medication may affect heart rate, blood pressure,
INJURY, OR DEATH. When required by applicable and circulation.
Fastener
local codes and/or by the Authority having jurisdiction
Safe Area g) People with infectious diseases should not use a
Fastener (AHJ); Connect only to a branch circuit that is
Safe Area Flexed spa or hot tub.
protected by a ground-fault circuit interrupter (GFCI).
Diaphragm Contact a qualified electrician if you cannot verify that h) Exercise care when entering or exiting the spa
Travel the circuit is protected by a GFCI. Make sure such a or hot tub.
1/8" Bit
Distance GFCI is provided by the installer and should be tested i) Water temperature in excess of 100°F (38°C)
on a routine basis. To test the GFCI, push the test may be injurious to your health.
Air Blower
Blower Body indicating the possibility of electrical shock. Do l) Do not permit any electric appli-
not use the device. Disconnect the device and ance (such as a light, telephone,
have the problem corrected by a qualified service radio, or television) within five 5 feet
representative before using. (1.5m) of a spa or hot tub.
CAUTION - To reduce the risk of injury, do not permit
Blower must be affixed to the plumbing using the fasteners children to use this product. Attention installer: This manual contains important
recommended in these instructions. Failure to do so may - Jandy Blowers are powered by high-voltage
Models:
allow the blower to come free of the plumbing during oper- electric motors and must be installed by a licensed information about the installation, operation and safe use
ation which could damage equipment and prevent proper or - certified electrician or a qualified swimming pool of this product. This information should be given to the
blower operation. service technician. owner/operator of this equipment.
240V Wiring
3″ damage that could result INJURY OR DEATH. Before attempting installation, ensure that all
0.27
8 Factor in electrocution causing BELOW GRADE INSTALLATION power to the device is disconnected/turned off at the circuit breaker.
Be careful not to damage or abrade any wiring or other components.
1.2 ″ 0.15 Total Airflow severe injury or death.
Jet 0.1 SCFM Wate
r Jet
(Standard Cubic Feet Per Minute) From Blower Motor
Power Center Line 1 Line 2
Determine Blower Needed ON ON