0% found this document useful (0 votes)
30 views29 pages

User Manual: All Rights Reserved. Specification Are Subject To Change Without Notice

This user manual outlines the features and operation of a battery-powered digital multimeter with a one-year warranty. It includes safety instructions, product specifications, and detailed measurement methods for various electrical parameters such as voltage, current, resistance, and temperature. Users are advised to follow safety precautions to avoid electric shock and ensure accurate measurements.

Uploaded by

diomarrs
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views29 pages

User Manual: All Rights Reserved. Specification Are Subject To Change Without Notice

This user manual outlines the features and operation of a battery-powered digital multimeter with a one-year warranty. It includes safety instructions, product specifications, and detailed measurement methods for various electrical parameters such as voltage, current, resistance, and temperature. Users are advised to follow safety precautions to avoid electric shock and ensure accurate measurements.

Uploaded by

diomarrs
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 29

User Manual

All rights reserved.


Specification are subject to change without notice.
LIMITED WARRANTY
AND LIMITATION OF
LIABILITY
Customers enjoy one-year warranty
from the date of purchase.
This warranty does not cover fuses,
disposable batteries, damage from
misuse accident, neglect, alteration,
contamination, or abnormal conditions
of operation or handling, including
failures caused by use outside of the
product's specifications, or normal wear
and tear of mechanical components.
catalogue

Title page

summary........................................................1
safety instruction.................................1
product description..............................3
LCD.....................................................3
Function KEYS....................................5
rotary switch........................................6
input port.............................................9
measuring method.......................................10
Measure DC voltage..........................10
Measure AC voltage..........................10
Measure the ACcurrent&DCcurrent...11
Measure resistance...........................12
Measure continuity............................12
Measure diode..................................13
Measure capacitance........................13
Measure frequency...........................14
Measure duty cycle...........................14
Measure temperature........................15
Meas u re in duc tanc e..... ..............1 5
N C V n o n - c o n t a c t d e t e c t i o n .........16
Tritrode hFE value measurement.... 1 6
Maintenance................... ....................................17
Clean products........................................17
Replace the battery................................18
Change the fuse..........................................18
Technical indicators............................................19
General technical indicators......................19
Mechanical technical indicators..................19
Environmental technical indicators.............20
Electrical and technical indicators.......................21
Summary
This product is a battery-powered, manual range
digital multimeter with true rms.The instrument
has a 6000 counts display, using an LCD display
with a backlight function for clear readings.
Safety Instructions
To avoid possible electric shock, fire, and personal
injury, please read the safety precautions before
use.Use the product only for its intended purpose,
otherwise the protection provided by the product may
be impaired.
• Please check the case before using the product.
Check for cracks or plastic defects.Please double
check the insulators near the input port.
• Please follow this "User Manual", use the correct
input port and the correct gear setting, and measure
within the range specified in this "User Manual".
• Do not use this product around explosive gases and
vapors or in humid environments.

1
• Please keep your fingers behind the guard of the test
lead probe
• When this product is connected to the circuit under
test, do not touch the unused input port.
• Please disconnect the test lead and the circuit before
changing the measure gear.

• When the DC voltage to be measured is higher than

36V, or the AC voltage is higher than 25V, it may

cause serious injury to the human body, and the user

should pay attention to avoid electric shock.

• Please select the correct measure gear and range to

avoid instrument damage or personal injury. When the

measured parameter exceeds the range of the

instrument, the screen will display“ ”

• When the battery voltage is low, it may affect the

accuracy of the test results. Please replace the battery

in time. Do not use this product without the battery

cover closed properly.

2
product description
LCD
② ① ③ ⑤⑥⑧⑦ ⑩ ⑫ ⑪

④ ⑬

⑲ ⑪

⑱ ⑭


① The product automatically selects the
range with the best resolution
② User manually selects the range

Relative value measurement: When entering


③ REL mode, the display screen will save the
current reading as a reference value, which
will be automatically subtracted from each
subsequent measurement.

④ Display freezes current reading

⑤ The display shows the maximum reading

⑥ Diode test

⑦ The display shows the minimum reading

⑧ Continuity test

3
⑨ Automatic shutdown display symbol

⑩ Secondary Display Screen

⑪ Duty cycle test

⑫ Temperature Test - Fahrenheit

⑬ Frequency Test (Hertz)

⑭ Temperature Test - Celsius

⑮ Analog bar chart

The product can accurately measure


⑯ alternating current that conforms to the
sine wave waveform and does not
conform to the sine wave waveform
⑰ Main Display Screen

⑱ The battery is low, please replace the


battery
⑲ AC

⑳ DC

Units of measurement

4
function button
① ② ③ ④

Selection key:Pressing this key can switch between the gear


modes currently indicated by the knob switch, as follows:
1. Diode/Continuity Test
2. DC current (A)/AC current (A)
3. DC current (mA)/AC current (mA)
4. DC current (μA)/AC current (μA)
① 5. Press and hold for 2 seconds to turn on the flashlight, and
press and hold again to turn off the flashlight.

measurement key: Press this key in the capacitance, triode,


② voltage, current measurement mode to enter the relative value
measurement mode; if you need to cancel, press it again to exit

measurement key: Press this key once to enter the maximum


value measurement mode, press it again to switch to the
③ minimum value measurement mode; press and hold for 2
seconds or switch gears to exit.

Press this key briefly to keep the current reading on the screen,
and press it again briefly to cancel the hold; press and hold this
④ key for 2 seconds to turn on the screen backlight, and press and
hold again to turn off the backlight.

5
knob switch

Turn off the product in gear this position.


• If there is no function switching or knob operation
within 15 minutes after turning on, this product
will automatically shut down.
• One minute before the automatic shutdown, the
product's built-in buzzer will sound five "beeps" to
remind.

• If you want to restart the instrument after


automatic shutdown, turn the dial switch to
restart.
• To disable the auto shutdown function, press
and hold the SEL key before turning on the
device. If the cancellation is successful, the built-
in buzzer will sound four "beep" tones, and the
clock icon " " on the screen will disappear.

6
Non-contact voltage detection

DC voltage≤600mV

DC voltage≤6V

DC voltage≤60V
DC voltage≤600V
DC voltage≤1000V
AC voltage≤750V
AC voltage≤600V
AC voltage≤60V
AC voltage≤6V
AC voltage≤600mV
DC current mode:≤6000uA
AC current mode:≤6000uA
DC current mode:≤60mA
AC current mode:≤60mA
DC current mode:≤600mA
AC current mode:≤600mA

7
DC current mode:≤20A
AC current mode:≤20A
Celsius:-20~1000
Fahrenheit:-4~1832

Low voltage high frequency gear,


duty cycle gear:1%~99%
Inductance gear: ≤60H,
automatic range
Diode gear: more than 3.3V will
display “ ”
Continuity gear: the buzzer
sounds when it is less than 50Ω
Resistance gear:≤600Ω

Resistance gear:≤6KΩ

Resistance gear:≤60KΩ

Resistance gear:≤600KΩ

Resistance gear:≤6MΩ

Resistance gear:≤60MΩ

Capacitance gear: ≤60mF,


automatic range
Transistor hFE value
measurement gear: 0~1000β
8
input port

Input port for current measurement (≤20A)

Input port for current mA/uA and inductance


measurement
mA≤600mA,uA≤6000uA
Inductance automatic measurement ≤60H

Common port for all measurements


Input ports for the following measurements:
AC/DC voltage
resistance
capacitance
frequency
temperature
Continuity
diode

9
Measurements Instruction
Measure DC Voltage
1. Insert the black test lead into the COM port and the red test lead
into the port.
2. Rotate the knob to the DC voltage range, and select the
appropriate measurement range (there are five ranges from
600mV to 1000V) based on the magnitude of the signal being
measured.Touch the probes to the correct test points of the
circuit to measure the voltage.
3. Make sure to use the test leads to make contact with the correct
testing point on the circuit.
4. Read the voltage value displayed on the screen.

Measure AC Voltage
1. Insert the black test lead into the COM port and the red test lead
into the port.
2. Rotate the knob to the AC voltage range and select the
appropriate measurement range (there are five ranges from
600mV to 750V) based on the magnitude of the signal being
measured.Touch the probes to the correct test points of the
circuit to measure the voltage.
3. Make sure to use the test lead probe to make contact with the
correct testing point on the circuit.
4. Read the voltage value displayed on the screen.
*Do not measure a voltage that exceeds the maximum rated
testing value, as doing so may damage the instrument and
potentially cause harm to yourself.
*When measuring high-voltage circuits, it is necessary to avoid
touching the high-voltage circuits.

10
Measure AC/DC Current
1. Rotate the knob to the current measurement area, and the current

range indicator light will light up.

2. Select the appropriate measurement range based on the type and

magnitude of the current being measured (with a range of 6000uA to

20A, divided into 5 ranges). Press the SEL button to switch between

AC and DC current measurement.

3. Black test lead should be inserted into the COM port. When measuring

current in the range <600mA, the red test lead should be inserted into

the mAuA port. If the measured current is in the range of 600mA~20A,

the red test lead should be inserted into the 20A port.

4. Disconnect the circuit path to be measured, and insert the meter

probes into the

5. To read the current value displayed on the screen.

* The measured current should not exceed the maximum rated


test value, otherwise there is a risk of damaging the instrument
and endangering personal safety.
* If the magnitude of the current to be measured is unknown, it
should be tested and determined using the 20A range first. Then,
according to the displayed value, select the corresponding test
terminal and current range.
* Do not input voltage in this gear position.
11
Measure Resistance
1. Insert the black test lead into the COM port, and the
red test lead into the port.
2. Turn the knob to the resistance range, and rotate the
knob switch to select the appropriate range
(0Ω~60MΩ, divided into 6 ranges) according to the
resistance value to be measured.
3. Connect the test leads to the desired test points in the
circuit.
3. Read the resistance value displayed on the screen.
*Before measuring resistance, it is necessary to confirm
that all power sources of the circuit being tested are turned
off, and all capacitors have been completely discharged. It
is strictly forbidden to apply voltage in this mode.
Measure continuity
1. Insert the black probe into the COM port and the red probe
into the port.

2. Turn the knob switch to the gear, and press the SEL
key to enter the continuity test mode
3. Connect the test leads to the two points of the circuit being
tested.
4. If the resistance value is less than 50Ω, the buzzer will sound,
indicating a short circuit. If there is no response, it means an
open circuit..

*Do not input the voltage in this gear position.


12
Test Diodes
1. Insert the black test lead into the COM port and the red
test lead into the port.
2. Turn the knob switch to the
3. Use the red test probe to connect to the positive pole of
the diode being tested, and the black test probe to
connect to the negative pole of the diode being tested.
4. Read the forward voltage displayed on the screen.

*Do not input the voltage in this gear state.


*Before testing, the power should be disconnected
and all high-voltage capacitors should be
discharged.

Measure Capacitance
1. Insert the black test lead into the COM port and the red test lead into
the port.
2. Turn the knob switch to the gear.
3. Connect the red test lead to the positive terminal of the capacitor to be
measured, and connect the black test lead to the negative terminal of
the capacitor. The instrument will automatically select the appropriate
range based on the measured capacitance value
4. After the reading is stable, read the capacitance value displayed on the
screen..

*If you want to measure a high-voltage capacitor,


you should discharge it before testing.

13
Measure Frequency
1. Insert the black test lead into the COM port, and
insert the red test lead into the port.
2. Turn the knob switch to "measure low-voltage
high-frequency" mode, or when measuring in AC
voltage/current mode, the secondary display will
show the frequency reading value (for high-voltage
low-frequency measurement).
3. Use the test probe of the meter to contact the circuit
test point you want to test..
4. Read the frequency value displayed on the screen..

Measure Duty Cycle

1. Insert the black test lead into the COM port and the
red test lead into the port.
2. Turn the knob switch to the gear ,
press the Hz %
button once to toggle to the Duty Cycle Mode .
3. Use the test probes to touch the desired test point in
the circuit.
4. Read the duty cycle value displayed on the
secondary screen.
14
Measure Temperature
1. Insert the black plug of the thermocouple into the COM port
and insert the red plug into the port.
2. Turn the knob switch to the mode for measuring
temperature. At this time, the screen will display ambient
temperature by default, with the primary display in Celsius (℃)
and the secondary display in Fahrenheit (℉).
3. Use the temperature measuring probe of the thermocouple
to contact the point to be measured.
4. Read the temperature value displayed on the
screen.

*Do not input the voltage in this gear position.


*When measuring high temperature, it is prohibited
to touch the test point with the human body to
avoid burns

Measure inductance
1. Insert the black test lead into the COM port, and insert the red
test lead into the "mAuA/Lx" port.

2. Turn the knob switch to the "L" inductance mode.


3. Use the red and black test leads to respectively detect the two
ends of the inductor to be tested. The instrument will
automatically select the appropriate range based on the
measured inductance value.

4. After the reading is stable, read the inductance value displayed on


the screen.

• Do not input the voltage in this gear position.


15
Test NCV
1. Turn the rotary switch to .
2. Hold the product and move it around, the built- in
beeper will beep when the inner sensor
detects AC voltage nearby. The stronger the voltage
is, the quicker the beeper beeps.

3. If the red test pen is inserted into the " " end alone,
and the test probe of the test pen is used to contact the
detection power plug respectively, if the buzzer alarms
strongly, it is the live wire; otherwise, it is the neutral wire
or ground wire.

Test triode hFE value

1. Turn the rotary switch to

2. Determine whether the triode to be measured is


NPN or PNP type, respectively insert the base (B),
emitter (E), and collector (C) into the triode
measurement socket.

3. Read the approximate hFE value on the display


(range 0~1000β).

16
Maintenance
Except for battery and fuse replacement, please do not
attempt to repair or modify the circuit of the product
unless you have the appropriate qualifications,
calibration, performance testing, and maintenance
instructions.
Cleaning instructions:
Please use a damp cloth and mild cleaning agent to
clean the exterior of the product. Do not use corrosive
agents or solvents. Dust or moisture on the test ports
may affect the accuracy of the readings.
*Before cleaning the product, please remove all input
signals.

17
Replace the Batteries
When the symbol “ ”appears on the display screen, the
battery should be replaced. Please follow the steps below:
1. Before replacing the battery, please disconnect the test
leads and turn off the unit.
2. Unscrew the screw that secures the battery cover and
open the battery door.
3. Remove the old battery and replace it with a new one of
the same type.
4. Install the battery door and tighten the screw.

Replace the Fuses


When the fuse is blown or faulty, follow the steps below to
replace it:
1. Before replacing the fuse, remove the test leads and
turn off the device.
2. Unscrew the four screws on the back cover and one
screw that secures the battery door. Remove the back
cover.
3. Replace the old fuse with a new fuse of the same
model.
4. Reattach the back cover and battery door, and tighten
the screws.

18
Specifications
General Specifications
Display (LCD) 6000 counts
Ranging Auto/Manual
Material ABS/PVC
Update Rate 3 times/second
Ture RMS √
Data Hold √
Backlight √
Low Battery √
Indication
Auto Power Off √

Mechanical Specifications
Dimension 176*91*47mm
Weight 330g(no battery)
Battery Type 1.5V AA Battery * 3
Warranty One year

19
Environmental Specifications
Temperature 0~40℃
Operating
Humidity <75%
Temperature -20~60℃
Storage
Humidity <80%

20
Electrical Specifications

Function Range Resolution Accuracy


600.0mV 0.1mV
DC Voltage 6.000V 0.001V
(V) 60.00V 0.01V ±(0.5%+3)
(mV)
600.0V 0.1V
1000V 1V
600.0mV 0.1mV
AC Voltage
(V) 6.000V 0.001V
(mV) ±(1.0%+3)
60.00V 0.01V
600.0V 0.1V
750V 1V

DC Current
20.00A 0.01A ±(1.2%+3)
(A)

21
Function Range Resolution Accuracy

DC Current 60.00mA 0.01mA


(mA)
600.0mA 0.1mA ±(1.2%+3)

DC Current
6000μA 1μA
(μA)

AC Current
20.00A 0.01A
(A)

AC Current 60.00mA 0.01mA ±(1.5%+3)


(mA)
600.0mA 0.1mA

AC Current
6000μA 1μA
(μA)
600.0Ω 0.1Ω
6.000kΩ 0.001kΩ
60.00kΩ 0.01kΩ ±(0.5%+3)
Resistance
600.0kΩ 0.1kΩ
6.000MΩ 0.001MΩ
60.00MΩ 0.01MΩ ±(1.5%+3)
22
Function Range Resolution Accuracy
9.999nF 0.001nF ±(5.0%+20)
99.99nF 0.01nF
999.9nF 0.1nF
9.999μF 0.001μF ±(2.0%+5)
Capacitance
99.99μF 0.01μF
999.9μF 0.1μF
9.999mF 0.001mF
±(5.0%+5)
60.00mF 0.01mF
9.999Hz 0.001Hz
99.99Hz 0.01Hz
999.9Hz 0.1Hz

Frequency 9.999kHz 0.001kHz ±(0.1%+2)


99.99kHz 0.01kHz
999.9kHz 0.1kHz
9.999MHz 0.001MHz
Duty Cycle 1%~99% 0.1% ±(0.1%+2)
23
Function Range Resolution Accuracy
(-20~1000)℃ 1℃
Temperature ±(2.5%+5)
(-4~1832)℉ 1℉
Diode √
Continuity √
NCV √
Triode hFE approximation value
0~1000β

Function Range Resolution Accuracy


6.000mH 0.001mH ±(5.0%+50)
60.00mH 0.01mH
inductan 600.0mH 0.1mH ±(3.0%+10)
ce
6.000H 0.001H
60.00H 0.01H ±(5.0%+50)

24