0% found this document useful (0 votes)
781 views23 pages

Vimec s11

The document is a technical file for the S11+ wiring diagram, detailing the functional drawings, connection diagrams, and safety devices for the system. It includes information on power supplies, inputs, outputs, control panels, and alarm settings. Additionally, it provides instructions for insulation testing and maintenance procedures.

Uploaded by

dejandizala
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
781 views23 pages

Vimec s11

The document is a technical file for the S11+ wiring diagram, detailing the functional drawings, connection diagrams, and safety devices for the system. It includes information on power supplies, inputs, outputs, control panels, and alarm settings. Additionally, it provides instructions for insulation testing and maintenance procedures.

Uploaded by

dejandizala
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 23

S11+

78502005
rev. 0
ENGLISH

410Z

03/09/2021 Approved: Benassi


VIMEC reserves the right to make any modification and change to its products at any time in compliance with the technical developments.
TABLE OF CONTENTS CAPTIONS
SHEET DESCRIPTION SYMBOL DESCRIPTION
AL 1 28V-7A POWER SUPPLY
2-5 Functional drawing BATT 1/2 AUXILIARY POWER BATTERIES
2 Drive BUZ BUZZER
3 Power supplies BUZ_EXT EXTERNAL BUZZER
C BELL BUTTON
4 Inputs and safety devices C.B. POWER SUPPLY AND BATTERY CHARGER MANAGEMENT CIRCUIT
5 Outputs and controls CH CONTROL PANEL ACTIVATION KEY
CSB+ ON-BOARD SLIDING CONTACT FOR PLATFORM MICROSWITCH BYPASS
6-19 Connection and assembly drawings
CSBY SLIDING BLOCK ON STRUCTURE FOR PLATFORM MICROSWITCH BYPASS
6 Control board connection diagram – Schneider CTSB+ ON-BOARD SLIDING CONTACT FOR FLOOR 0 OR 1 LOCK ACTIVATION
7 Control board connection diagram – Fuji CTS0 SLIDING BLOCK ON STRUCTURE FOR FLOOR 0 LOCK
8 Main structure connection diagram CTS1 SLIDING BLOCK ON STRUCTURE FOR FLOOR 1 LOCK
D_B ON-BOARD DOWNWARD RECALL
9 Cabin connection diagram
D_P DOWNWARD FROM FLOOR RECALL
10 Main structure and cabin general diagram EM EMERGENCY MAIN SWITCH
11 Floor connection general diagram FEM ELECTROMAGNETIC BRAKE
12 Floor connection diagram, door INCLINO ON-BOARD LOAD DETECTOR
K1,K2 RUN GENERAL RELAY
13 Floor connection diagram, gate
KD DOWNWARD RELAY
14 Photocells connection diagram KFEM BRAKE CONTROL RELAY
15 Main structure wiring diagram KS UPWARD RELAY
16 Carriage wiring diagram KP0 RELAY FOR MOTOR-OPERATED DOOR CONTROL AT FLOOR 0
KP1 RELAY FOR DOOR/MOTOR-OPERATED GATE CONTROL AT FLOOR 1
17 Platform wiring diagram L_CAB CABIN LIGHT
18 Control panel wiring diagram L_EM EMERGENCY MODE PILOT LIGHT ON
19 Magnet layout diagram L_OL OVERLOAD PILOT LIGHT
LT1 PIT BLINKING LIGHT
M1 MAIN ELECTRIC DRIVING MOTOR
20 Insulation tests M2 ELECTRIC MOTOR FOR EMERGENCY DOWNWARD OPERATION
MP0 MOTOR FOR MOTOR-OPERATED GATE CONTROL AT FLOOR 0
21 Alarms, signals and settings MP1 MOTOR FOR MOTOR-OPERATED GATE CONTROL AT FLOOR 1
P0 DOOR CONTACT AT FLOOR 0
P0A ON-BOARD GATE CONTACT
P1 DOOR CONTACT AT FLOOR 1
Q0 LOCK CONTACT AT FLOOR 0
Q1 LOCK CONTACT AT FLOOR 1
Q2 UPWARD LIMIT SWITCH SENSOR
Q3 DOWNWARD LIMIT SWITCH SENSOR
Q4 GUARD BOARD MICROSWITCH
Q45 PIT STAKE MICROSWITCH
Q4P ON-BOARD GATE LOCK MICROSWITCH
Q5 PLATFORM BOTTOM SAFE EDGE MICROSWITCH
Q6,Q6L OVER-RUN MICROSWITCH, OVER-RUN LOW POSITION
Q8 NUT OR SAFETY GEAR MICROSWITCH
Q9 PHOTOCELLS CONTACT
QME EMERGENCY OPERATION SAFETY MICROSWITCH
R1 EMERGENCY MODE ACTIVATION RELAY
R2,R3 EMERGENCY OPERATION CONTROL RELAY
R+,R- EMERGENCY OPERATION CONTROL RELAY
RFEM+,RFEM- BRAKE CONTROL RELAY DURING EMERGENCY OPERATION
S_B ON-BOARD UPWARD RECALL
S_P UPWARD FROM FLOOR RECALL
SB1 EMERGENCY OPERATION ACTIVATION BUTTON
SB22 EMERGENCY STOP IN PIT
YA0 DRIVE LOCK COIL AT FLOOR 0
YA1 DRIVE LOCK COIL AT FLOOR 1

Table of contents and captions S11+ wiring diagram technical file

FOGLIO 1 DI 21
MAIN CONTROL BOARD

EMERGENCY
CONTROL PANEL
EMERGENCY
OPERATION BOX

INVERTER

JPEB Safety
devices line

* Connections on when the motor-


operated emergency operation is not
provided

Power supplies and drive S11+ wiring diagram technical file


Functional drawing
FOGLIO 2 DI 21
Floor controls – door/gate operators

Logic power input

Positive pole downstream the safety line, for:


- brake
- general relay for running
- relay for on-board emergency operation

Power supplies S11+ wiring diagram technical file


Functional drawing
FOGLIO 3 DI 21
MAIN CONTROL BOARD

Inputs and safety devices S11+ wiring diagram technical file


Functional drawing
FOGLIO 4 DI 21
MAIN CONTROL BOARD

P1 door/gate opening P0 door/gate opening


control control

Outputs and controls S11+ wiring diagram technical file


Functional drawing
FOGLIO 5 DI 21
Remote control

INVERTER
Description

Brake
24V-7A power supply

Description
Upward
Mains

Downward

Common inputs

Control board connection diagram S11+ wiring diagram technical file


- Schneider
FOGLIO 6 DI 21
FUJI
INVERTER

Description

Brake
24V-7A power supply

Description
Upward
Downward
Mains

Common inputs

Remote control

Description

Control board connection S11+ wiring diagram technical file


diagram - Fuji
FOGLIO 7 DI 21
Down
Up
Downward on-board control
Upward on-board control
Downward limit switch
Upward limit switch
Only with door at floor 0

Unit ready to start


Cabin light

black

Opening control
Upward run control from the floor

Upward on-board control


Downward on-board control

Emergency pilot light


Downward run control from the floor

Bell
Inclinometer
grey Overload pilot light

Opening control

Main structure connection S11+ wiring diagram technical file


diagram
FOGLIO 8 DI 21
Signal

Inclinometer

Cabin connection diagram S11+ wiring diagram technical file

FOGLIO 9 DI 21
MAIN STRUCTURE CABIN
Photocells
Cabin control panel
Option - motor-operated Telephone dial pad
emergency operation (option)

Electromagnetic brake 24V DC


Emergency control GSM
(option)
panel

No motor-operated
emergency
operation

Only with gate on board

Only with gate


on board

Only with Q4 (option)


black grey closed shaft

Mains
Inclinometer
Option (option)
Only with open
shaft
Closed shaft
(option in
open shaft)

Main structure and cabin S11+ wiring diagram technical file


Installation general diagram
FOGLIO 10 DI 21
MANUAL OR MOTOR-OPERATED DOOR/GATE

Additional remote call, as option

Option column
unit, as option
F
L
Only with motor-operated door
O
O
R
1

Only with motor-operated gate

ON-BOARD GATE MANUAL OR MOTOR-OPERATED DOOR/GATE


Remote call Additional remote call, as option

Option column
unit, as option Option column
unit, as option

F
L
O Only with motor-operated door

O
R
0
Pre-wired
connector
2255871 Only with
motor-operated gate

Floors S11+ wiring diagram technical file


Installation general diagram
FOGLIO 11 DI 21
Only with motor-operated door
DOOR CONNECTIONS

+24V
Button
GND

Floor connections S11+ wiring diagram technical file


Doors
FOGLIO 12 DI 21
GATE CONNECTIONS

Only with motor-operated gate

Right gate
Left gate
right

JF0/1
+24V
Button
GND

left

Floor connections S11+ wiring diagram technical file


Doors
FOGLIO 13 DI 21
4-6 photocells 2 photocells

TX red TX red

TX white TX white

3 photocells 1 photocell

TX red TX red

TX white TX white

Photocells S11+ wiring diagram technical file

FOGLIO 14 DI 21
Main structure wiring diagram S11+ wiring diagram technical file

FOGLIO 15 DI 21
WITH ON-BOARD GATE

FRONT VIEW

only with on-board gate

low overrun microswitch


(option for closed shaft)

Carriage wiring diagram S11+ wiring diagram technical file

FOGLIO 16 DI 21
only with front guard board

only with on-board gate

Platform wiring diagram S11+ wiring diagram technical file

FOGLIO 17 DI 21
Telephone dial pad
(option)

GSM Photocell card


Control panel
(option)

green
yellow

brown
white

Control panel wiring diagram S11+ wiring diagram technical file

FOGLIO 18 DI 21
“A0” view Front view

Floor 1
Floor level

Floor 0
Floor level

Magnet layout S11+ wiring diagram technical file

FOGLIO 19 DI 21
INSTRUCTIONS FOR INSULATION TESTING POWER SUPPLY AND POWER
1) Stop the cabin between two floors; 1) By applying a voltage of 500Vdc, check that the resistance between the power cables is ≥ 0.5
2) Open the main switch; MOhm (2256179 wiring):
3) Disconnect connectors JQN, JQG, JQM, JA, M3 from 20640001 board; - L (brown) and N (blue)
4) Disconnect the 2 connectors (JRAL and JAL) from power supply 8882028; - L (brown) and earth
5) Check that the inverter is power supplied and wait for 3 minutes, then disconnect from the inverter - N (blue) and earth
the contacts to the terminals L (or L1) and N (2256179 wiring), U, V and W (2255879 wiring).

2) By applying a voltage of 500Vdc, check that the resistance between the power cables is ≥ 0.5
MOhm (2255879 wiring):
- U (black) and earth
- V (brown) and earth
- W (grey) and earth
- U (black) and V (brown)
- U (black) and W (grey)
- V (brown) and W (grey)

SAFETY DEVICES LINE


On connectors JQG and JQN from the main wiring:
1) Check the earth insulation of terminal N8B, by applying a voltage of 500Vdc and verifying that
the resistance is ≥ 0.5 MOhm.
2) Check the earth insulation of terminal G4A, by applying a voltage of 500Vdc and verifying that the
resistance is ≥ 0.5 MOhm.
24V-7A power supply

Insulation tests S11+ wiring diagram technical file

FOGLIO 20 DI 21
ALARMS AND SIGNALS: SETTINGS:

ALARM DESCRIPTION WARNING SOUND 1) Activating/deactivating the lock at floor 0:


A0 Emergency button pressed or bell button pressed Continuous sound The procedures for lock activating and deactivating are the same. By performing this procedure, if the
A1 The door or gate remained open (90-second delay) Cyclic: 1s ON - 1s OFF - 10s break
lock was deactivated (default setting) then it is activated, on the contrary if it was activated, it is then
A2 The door or gate do not open (30-second delay) Cyclic: (1s ON - 1s OFF) x2 - 10s break
deactivated.
A3 Person stuck in Cyclic: (1s ON - 1s OFF) x3 - 10s break
a) Switch off the panel power supply by pressing the emergency button
A4 Maintenance in pit alarm Cyclic: 1s ON - 1s OFF
b) Place the magnets on Q2 and Q3
A5 Buttons 0-1 pressed simultaneously Close beeps until the situation persists
c) Switch on the panel power supply with the magnets properly placed, two close “BEEPs”
A6 230Vac power supply failing or inverter in alarm No sound (only emergency pilot light ON)
indicate that the lock (which was activated) deactivation is completed
Signal for safety device open (photocells, platform bottom
A7
safe edge or open door) upon trying to start
3 close beeps d) Return the magnets to their proper position
A8 Run activation safety circuit failure Cyclic: (2 close beeps + 0.5s break) x2 - 3s break

Overload detected at floor (only with optional inclinome-


Continuous sound until a call button is pressed.
(overload pilot light ON even when no call button is
2) Calibrating the tilt sensor for overload detection:
A9
ter) pressed) If the inclinometer for overload detection is provided, it has to be calibrated:
a) Move the platform to floor 0 and remove any load
b) Set JP1 in position 2
c) Move the platform up to floor 1
d) Set JP1 in position 1
e) After a few seconds, set JP1 in position 2.
At this point, the zero calibration of the tilt sensor should now be completed.

If the inclinometer is not provided, set JP1 in position 1.

3) Maintenance in pit alarm reset:


Upon opening the door lock at floor 0, if the platform is not at floor zero, the system locks up
completely. It is a procedure to preserve the safety of the person who is accessing the space below
the platform.
After completing the maintenance operations under the platform, a reset procedure must be carried
out:
a) Make sure that no person nor object has remained under the platform. Then close the door
lock at floor 0.
b) Press the mushroom head emergency button, wait for 8 seconds then keep pressed both up
and down buttons and release the emergency button. Keep these buttons pressed until hearing
close BEEPs coming from the main panel.
The alarm is now reset.

Alarms, signals and settings S11+ wiring diagram technical file

FOGLIO 21 DI 21