0% found this document useful (0 votes)
19 views1 page

Schedule of Columns:: Maintenance Area Maintenance Area Typical Beam Details

The document outlines structural details for a construction project, including specifications for various components such as CEE purlins, tubular rafters, and footings. It provides dimensions, reinforcement schedules, and material specifications for different areas including a boiler room, maintenance area, and guard house. Additionally, it includes notes on construction standards and approvals from relevant authorities.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
19 views1 page

Schedule of Columns:: Maintenance Area Maintenance Area Typical Beam Details

The document outlines structural details for a construction project, including specifications for various components such as CEE purlins, tubular rafters, and footings. It provides dimensions, reinforcement schedules, and material specifications for different areas including a boiler room, maintenance area, and guard house. Additionally, it includes notes on construction standards and approvals from relevant authorities.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

50 X 100 X 1.

2 MM CEE PURLINS
SPACED @ 600 MM.O.C
50 X 150 X 2MM
8000 8000 TUBULAR RAFTER

2300 3475 2225 2300 3475 2225


C2a-F1a C2a-F1a C2a-F1a
WF1 WF1 RB2 RB2

2200
2200
WF1

WF1

3500

RB2

RB2
3500

RB2
WF1

WF1

1225
1225
C2a-F1a C2a-F1a C2a-F1a
WF1 WF1 RB2 RB2

8500
8500

RB2
WF1

5000

RB1

5075
WF1
5000

WF1

RB2
5075
10 mm DIA. STIRRUPS (SEE SCHEDULE)
MAIN REINFORCEMENT (SEE SCHEDULE)

C2a-F1a C1a-F1a 100 MM THK SLAB ON FILL


C2a-F1a
WF1 WF1 SPACED 400 MM.O.C. B.W. RB2 RB1

MID
SUPPORT
3000 5075 3000 5075

TYPICAL BEAM DETAILS


MAINTENANCE AREA MAINTENANCE AREA

50 X 75 X 1.2 MM CEE PURLINS SPACED


@ 600 MM.O.C
SCHEDULE OF COLUMNS : ( f'c = 21 MPa , fy = 275 MPa )

50 X 100 X 2MM

1107
C-1a C-2a C-3a
1107

TUBULAR RAFTER

2800 1500 2800 1500


C3a-F2a C3a-F2a 200mm
WF1 WF1 RB3 300mm 200mm

FOOTING TO ROOF BEAM

400mm
300mm

300mm
C3a-F2a

2400
RB3
WF1

2400
WF1

RB3
1300

RB3
1300

RB3

WF1 C3a-F2a C3a-F2a

RB3 RB3 SIZE: 300mm x 300mm SIZE: 200mm x 400mm SIZE: 150mm x 300mm
WF1 WF1 VERT.BARS: VERT.BARS: VERT.BARS:
C3a-F2a 100 MM THK SLAB ON FILL TIES: 1 SET TIES: 1 SET TIES: 1 SET
4300 4300
SPACED 400 MM.O.C. B.W.
NOTES :
GUARD HOUSE GUARD HOUSE
50 X 100 X 1.2 MM CEE PURLINS
SPACED @ 600 MM.O.C
50 X 150 X 2MM
TUBULAR RAFTER
3000 3000 3000 3000
100 mm CHB
C2a-F1a C2a-F1a
WF1 RB2
1500

F.F.L.
1500

WF1

C2a-F1a
WF1 RB2

3500
3500
WF1

RB2

N. G. L.
2000

C2a-F1a
2000

RB2
WF1

C2a-F1a C2a-F1a C2a-F1a

WF1 WF1 100 MM THK SLAB ON FILL RB2 RB2

SPACED 400 MM.O.C. B.W.

6000 6000

BOILER & COMPRESSOR ROOM BOILER & COMPRESSOR ROOM 125 mm CHB

N.G.L.

TYP. COL. FTG. DETAILS

SCHEDULE OF FOOTINGS ( ASSUMED SBC = 35 KPa )

SIZE
(mm) THICKNESS DEPTH OF
REINFORCEMENTS
WALL FTG. DETAILS SCHEDULE OF BEAMS : ( f'c = 21 MPa , fy = 275 MPa )
MARK (mm) EXCAVATION ALONG WIDTH ALONG LENGTH REMARKS
WIDTH LENGTH (mm)
TOP BOTTOM TOP BOTTOM SECTION REINFORCEMENTS
(mm) BAR SIZE
MARK AT SUPPORT AT MIDSPAN REMARKS
F1a 1200 1200 300 1200 - - ISOLATED
WIDTH DEPTH TOP BOTTOM TOP BOTTOM
F2a 1000 1000 250 1200 - - ISOLATED
ROOF LEVEL
RB1 200 400 16 4 3 4 3 A

RB2 200 300 16 2 2 2 2 A

RB3 150 300 12 2 2 2 2 A

NOTES :
A - 1 @ 50mm, 2 @ 100mm, 3 @ 150mm, REST @ 300mm O.C.
Project Title : Prepared & Submitted By: Reviewed and Checked By : Approved By: Sheet Content: Sheet No. :

FOUNDATION PLANS -
Republic of the Philippines

D:\projects\my_projects\minalin feedmill\PRDP-LOGO.png
DEPARTMENT OF AGRICULTURE
PHILIPPINE RURAL DEVELOPMENT PROJECT D:\projects\my_projects\minalin feedmill\MINALIN-LOGO.jpg
AQUA FEED MILL
FEDERICO L. REYES
Civil Engineer
Address: Brgy. San Jose, City of San Fernando, Pampanga
ENGR. EDEN M. SANTOS
MUNICIPAL ENGINEER

Recommending Approval :
BOILER & COMPRESSOR ROOM
MAINTENANCE AREA
GUARD HOUSE
ROOF FRAMING PLANS -
BOILER & COMPRESSOR ROOM
S8
Province of Pampanga HON. EDGARDO G. FLORES MAINTENANCE AREA
Project Location: PRC No: 0111348 Validity: 02-28-23 GUARD HOUSE
Municipality of Minalin Municipal Mayor
BRGY. BULAC, MINALIN, PAMPANGA
PTR No: 0551408
Issued at: City of San Fernado, Pampanga
Date Issued: 01-08-2021
TIN: 270-774-770
Engr. Eduardo M. Rivera
Mun. Planning Development Officer
SCHEDULE OF FOOTINGS , COLUMNS & BEAMS