Model: 13EOZ 60 Hz
11EFOZ 50 Hz
1-Phase Diesel
Marine Generator Set
Engine Features
D Diesel power
D Three cylinder
D Four cycle
D Closed cooling system
D Heat exchanger
D Lifting eyes
D Fuel lift pump
Generator Features
D Remote start connection availability
D Class F insulation
D Multivoltage adjustability
D 60/50 Hz capability
D Voltage regulation of ±2%
D Frequency regulation of ±5%
D Radio suppression
Optional Accessories
Generator Weights and Dimensions D Remote start and meter panel kit
D Seawater strainer
Without With D Siphon break
Sound Shield Sound Shield
D Sound shield
Weight, kg (lb.)
Wet 303 (669) 339 (750)
Dry 297 (654) 332 (735)
Length, mm (in.)
12 volt 931 (36.65)
1048 (41.25)
24 volt 944 (37.15)
Width, mm (in.) 563 (22.17) 654 (25.75)
Height, mm (in.) 661 (26.01) 692 (27.25)
See the drawings on the last page for detailed dimensions.
Generator Ratings
25_C (77_F) 25_C (77_F)
Model Series Voltage Hz Amps kW/kVA Ph
100/200 60 130/65 13/13 1
13EOZ
120/240 60 108.4/54.2 13/13 1
100/200 50 110/55 11/11 1
110/220 50 100/50 11/11 1
11EFOZ
220 50 50 11/11 1
240 50 45.8 11/11 1
RATINGS: Marine continuous ratings per ISO 3046, ISO 8528-1, and Kohler ISO rating guideline
2.14. Obtain technical information bulletin (TIB-101) on ratings guidelines for complete ratings
definitions.
Availability is subject to change without notice. Kohler Co. reserves the right to change the design or
specifications without notice and without any obligation or liability whatsoever. Contact your local
Kohler generator distributor for availability.
G2-61 (13EOZ) 3/02c
Application Data
Engine Operation Requirements
Engine Specifications 60 Hz 50 Hz Air Requirements 60 Hz 50 Hz
Manufacturer Yanmar Engine combustion air requirements,
L/min. (cfm) 1246 (44) 1048 (37)
Model 3TNE88
Engine/generator cooling requirements,
Type 4 cycle L/min. (cfm) 5946 (210) 4955 (175)
Cylinder, quantity 3 Fuel Consumption 60 Hz 50 Hz
Displacement, L (cu. in.) 1.64 (100.2) Diesel, Lph (gph) at % load
Bore and stroke, mm (in.) 88 x 90 (3.46 x 3.54) 100% 4.3 (1.14) 4.0 (1.06)
Compression ratio 18:1 75% 3.2 (0.85) 2.6 (0.71)
Combustion system Direct injection 50% 2.6 (0.68) 2.0 (0.55)
Rated rpm 1800 1500 25% 1.7 (0.46) 1.3 (0.35)
Max. power at rated rpm, HP 23.0 18.1 Note: The fuel consumption of the 60 Hz model is based on 13EOZ,
and the fuel consumption of the 50 Hz model is based on 11EFOZ.
Cylinder block material Cast iron
Cylinder head material Cast iron
Piston rings: quantity, type 2 compression/1 oil Engine Features
Crankshaft material Stamped forging
D One-side serviceability of fuel system, lubrication system,
Connecting rod material Forged carbon steel seawater pump, and air cleaner
Governor, type Centrifugal, mechanical D Low oil pressure cutout
D High water and high exhaust temperature cutouts
Engine Electrical
D Focused vibromounts
Engine Electrical System 60 Hz 50 Hz
D Belt guard
Battery, voltage 12 volt (standard)
24 volt (optional) D Disposable oil filter
Battery, charging 40-amp alternator D Oil drain valve and hose
Battery, minimum recommendation 500 CCA, 100 amp hr. D Air intake heater circuit for cold starting (optional)
Starter motor 1.8 kW Bendix, D Overspeed safety shutdown (optional)
gear-reduction
automotive type
Controller Features
Cooling D Rubber-mounted to isolate vibration
Cooling System 60 Hz 50 Hz D Safety shutdowns:
Capacity, L (qt.), approx. 4.4 (4.6) d Engine overheat
Heat exchanger type Yanmar, integral with
d Low oil pressure
water-cooled manifold
Seawater pump type Yanmar, belt-driven d Overspeed safety shutdown (optional)
Heat rejected to cooling water at rated D External 6-pin connector for remote panel harness
kW, wet exhaust, kW (Btu/min.) 13.7 (782) 11.6 (658) D Hourmeter for scheduling maintenance
Engine water pump flow, Lpm (gpm) 36.0 (9.5) 30.7 (8.1) D Start/stop switch
Seawater pump flow, Lpm (gpm) 22.7 (6.0) 18.9 (5.0) D Starter interlock to prevent reengagement of starter
whenever engine is running
Fuel D Plug/receptacle controller connections
Fuel System 60 Hz 50 Hz D Terminal connections:
Fuel shutoff solenoid Electric
d Clearly identified
Fuel pump Electric, rotary vane
d Corrosion resistant
Fuel pump priming Electric
d Possibility of misconnection eliminated
Maximum recommended fuel lift, m (ft.) 1.2 (4.0)
D Quick disconnect equipped on 22-pin wiring harness
Lubrication D Voltage/frequency adjustable PowerBoostt voltage
regulator
Lubricating System 60 Hz 50 Hz
Oil pan capacity with filter, L (qt.) 4.7 (5.0)
Type Pressure, trochoid pump
G2-61 (13EOZ) 3/02c
Application Data
Generator Features
D Brushless, rotating field design permits power to be
obtained from stationary leads.
D Rotor and stator are vacuum impregnated and coated with
high-bond epoxy varnish. Varnish helps prevent corrosion
in high-humidity areas.
D Rotors are dynamically balanced to minimize vibration.
D Copper windings ensure minimal heat buildup. Insulation
meets NEMA standards for class F insulation.
D Direct connected to the engine, the generator has sealed
precision ball bearings with a precision-machined steel
sleeve in the end bracket to prevent shaft misalignment and
extend bearing life.
D The generator is mounted on a dripproof tray.
D The generator is equipped with a four-lead reconnectable
stator.
Accessories
Sound Shield Remote Start and Two-Meter Panel Kit
Provides for highly effective silencing, ease of access for Allows starting/stopping from a location remote from the
engine/generator servicing, low maintenance, excellent generator set. The illuminated gauges include an engine
durability, and safety. oil pressure gauge and a water temperature gauge.
Overall dimensions are 152 mm (6 in.) by 152 mm (6 in.)
Siphon Break with a minimum mounting depth of 70 mm (2 3/4 in.).
Mandatory kit on generators installed below the waterline. Requires remote connection/extension harness and
Prevents the siphoning of flotation water into the engine. sender kit.
Line Circuit Breakers Remote Start and Four-Meter Panel Kit
Protect the generator from extreme overload. Allows starting/stopping from a location remote from the
generator set. The illuminated meters/gauges include a
Preheat Kit DC voltmeter, engine oil pressure gauge, water
temperature gauge, and an hourmeter that records total
Provides improved starting in cold climates. generator set operating hours. Overall dimensions are
229 mm (9 in.) by 152 mm (6 in.) with a minimum
Overspeed Shutdown Kit mounting depth of 102 mm (4 in.). Requires remote
Provides additional protection from overspeed damage. connection/extension harness and sender kit.
Seawater Strainer Sender Kit
Equipped with a clear viewing jar allowing for easy Provides senders necessary to make remote meter panel
cleaning and maintenance of the strainer for a more gauges functional.
efficient and longer-lived generator.
Remote Connection/Extension Harness
Ship-to-Shore Switch Provides additional wiring between all remote panels and
Allows immediate switching to Kohlerr generator set the controller connector. One required for each remote
power or shore power protecting the electrical system start and meter panel kit. Extension limited to a total of
from the possibility of simultaneous connection of both four kits and 23 m (75 ft.). Available in 4.6 m (15 ft.) and
power sources. Available as a three-pole ship-to-shore 7.6 m (25 ft.) lengths.
switch.
12-Inch Remote Wiring Harness
Remote Start Panel Equipped with a 6-pin connector on one end that is keyed
Allows starting/stopping from a location remote from the to a controller box connector. Equipped on the other end
generator set. Supplied with a 101 mm (4 in.) connection with pigtails for connection to a customer-supplied start
harness. Overall mounting dimensions are 128 mm switch, generator ON light, hourmeter, etc.
(5.04 in.) by 70 mm (2.76 in.) with a minimum mounting
Fuel Attachment Block
depth of 57 mm (2 1/4 in.).
Allows connection to the fuel inlet and return from one
point.
G2-61 (13EOZ) 3/02c
KOHLER CO., Kohler, Wisconsin 53044 USA
Phone 920-565-3381, Fax 920-459-1646
For the nearest sales and service outlet in the
US and Canada, phone 1-800-544-2444
KohlerPowerSystems.com
ADV-6512A-C
ADV-6512B-C
DISTRIBUTED BY:
NOTE: Dimensions in [ ] are inch equivalents.
NOTE: This drawing is provided for reference only and is not
intended for installation planning. Contact your local
distributor for more detailed information.
E 1999, 2000, 2001, 2002 by Kohler Co. All rights reserved.
G2-61 (13EOZ) 3/02c