OPTIKA Balances Catalogue
OPTIKA Balances Catalogue
B A L A N C E S
I T A L Y
4
Index
Legend
Electromagnetic Force Restoration. Coil in a Accumulator. Balance has internal accumulator or can
N S permanent magnet for the the most accurate weighings be used with optional external accumulator
EM-FR ACCU
High Resolution Load Cell. Strain gauge measure the Battery Operating. Balance can work using AA
deformation as change in electrical resistance AA batteries
LC-HR BATTERY
RS232 Data Interface. To connect the balance to Statistics Function. Shows Min, Max, Sum, Average,
printer, PC, peripheral devices. Standard deviation
RS 232 STAT
Measuring Units. Select the measuring unit that Gross-Net-Tare. Function shows simultaneousily gross,
balance will use to display weight net weight and tare.
UNITS NET
Piececounting. Function to count identical items, Database. Internal database to store data and drying
reference quantities are selectable. methods
PCS DATABASE
Checkweighing. Upper and lower limits can be set Textile Function. Determines the title of a thread,
- + individually, for dosing and portioning. measuring units: Tex, Td, Nm, Nc.
LIMITS TEXTILE
Percentual Weighing. Function calculates the variation Drying Modes: different temperature profiles are
% of a sample from reference value (100%) available for drying process
% WEIGH MODES
Totalization Function. Measures cumulative weight of Infrared Sensors. Touchless, to call TARE or PRINT
multiple items. Shows total and current weight functions without touching the balance
ADD SENSE
Animal Weighing. Accurate readings under unstable Touchscreen Display. 5 inch resistive display, user
conditions such moving laboratory animals. friendly, easy to use and intuitive.
TOUCH
ANIMAL
Density Determination. This function accurately 0.000000 LCD Display. Standard 8 digit LCD display with
determines density of a solid object or a liquid backlight
DENSITY LCD
Max Load (Peak hold). This function retains the peak 06.05.17
Graphic Display Text/graphical LCD dot matrix display
value in a series of consecutive weights
0.000000
with backlight.
PEAK GRAPHIC
Glp Setup. Allows storing identification data of balance, ION Ioniser. Integrated ioniser on the back of the balances
project and user. Date and Time
GLP IONISER
Date & Time. Balance shows current date and time Bluetooth. It is possible to connect bluetooth devices
CLOCK BLUETOOTH
Initial verification. According to 2014/31/EU available Memory. It is possible to store up to 5 different drying
VERIFIED
for balance with EC(/OIML) Type approval MEMORY programs
5
OPTIKA quick finder
M Internal External
Resolution Weighing Range Family Name Page Windshield
Verification Calibration Calibration
0,01mg 62g...220g SM 14 ■ ■
0,001g 520g...1200g CG 22 ❑ ❑ ■ ❑
0,001g 210g...420g EH 27 ❑ ■ ■
0,001g 210g...420g H 34 ■ ■
0,01g 4200g...6200g D 24 ❑ ❑ ■
0,01g 4200g...6200g DG 25 ❑ ❑ ■
0,01g 1000g...5200g F 30 ❑ ❑ ■
0,01g 1000g...5200g FG 31 ❑ ❑ ■
0,01g 620g...4200g I 35 ■
0,01g 200g...420g M 37 ■
0,1g 4500g...10000g G 32 ■
0,1g 4500g...10000g GG 33 ■
0,1g 3200g...6500g L 36 ■
0,1g 420g...2200g M 37 ■
Moisture Balances
Resolution Weighing Range Family Name Page Thermometer Calibration Halogen Infrared Lamp
6
OPTIKA quick finder
Touch
Graphic Integrated Multi
Lcd Display Screen Rs232 Units Glp Hook Power Bank
Display Ioniser Language
display
■ ▲ ■ ■ ■ ■
■ ▲ ■ ■
■ ▲ ■ ■ ■ ■
■ ▲ ■ ■ ■ ■
■ ▲ ■ ■
■ ▲ ■ ■ ■ ■
■ ▲ ■ ■
■ ▲ ■ ■ ■ ■
■ ■ ■ ■ ■ ▲
■ ■ ■ ▲
■ ■ ■ ■
■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■
■ ■ ■ ▲ ❑
■ ■ ■ ■ ■ ▲ ❑
■ ■ ■ ▲ ❑
■ ■ ■ ■ ■ ▲ ❑
■ ■ ■ ❑
■ ■ ■ ■
■ ■ ■ ■ ■ ❑
■ ■ ■ ■
■ ■ ■ ■ ■ ■
■ ■ ■ ▲ ❑
■ ■ ■ ■ ■ ▲ ❑
■ ■ ■ ■ ❑
■ ■ ❑
■ ■ ■ ■ ■ ■
■ ■ ■ ■ ❑
■ ■ ■ ■ ■ ■ ❑
■ ■ ■ ■ ❑
■ ■ ❑
▲ ▲ ▲ ■ ■ ▲ ▲ ■ ❑
Touch Internal
Graphic Multi Password
Screen Rs232 Units Glp Database,
Display Language protection
Display Save results
■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■
■ ■ ■ ■ ■
7
TS/TSI SERIES - Resolution 0,01mg SemiMicro Balances
N S % - + ₹ A
EM-FR USB PASSWORD TOUCH RS 232 UNITS PCS % WEIGH LIMITS ADD ANIMAL DENSITY STAT GLP LANG RECIPE TEXTILE DATABASE
8
Balance technical data
• Span drift (+ 10...+ 30 °C): +/– 2ppm/°C
• Dimensions LxWxH (mm): 345x215x345
• Weighing chamber dimensions LxWxH (mm):
162x171x225
• Power supply 110-230Vac, 50/60Hz; output
24V 500mA 13VA
• Net Weight: 6,7 Kg
• Net Weight -ION models: 7,2 Kg
Accessories
• Portable ioniser Ion-A15 (CNS0371)
ION • Serial Printer TLP-50, with date/time (CNS054)
IONISER
• Serial Printer DPP-250 (CNS007)
• Density KIT for solids and liquids (CNS002)
TSI models equipped with integrated • Serial to USB converter (CNS1002)
Ioniser on the back of the balance. • Serial cable for serial output to printer or PC (CNS743)
The ioniser has two way of operating: • Stylus pen for touchscreen (CNS021)
2 minutes or continuosily for max 8 • Factory Calibration certificate (CNS0333)
hours.
Main functions page for easy working Live color indication for check weighing
Manual tare input Clear and easy input for GLP function
9
TS/TSI SERIES - Resolution 0,1mg Analytical Balances
N S - + % ₹ A
EM-FR USB PASSWORD TOUCH DATABASE RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK GLP LANG RECIPE TEXTILE
10
Balance technical data
• Span drift (+ 10...+ 30 °C): +/– 2ppm/°C
• Dimensions LxWxH (mm): 345x215x345
• Weighing chamber dimensions LxWxH (mm):
162x171x225
• Power supply 110-230Vac, 50/60Hz; output
24V 500mA 13VA
• Net Weight: 6,7 Kg
• Net Weight -ION models: 7,2 Kg
Accessories
• Portable ioniser Ion-A15 (CNS0371)
ION • Serial Printer TLP-50, with date/time (CNS054)
IONISER
• Serial Printer DPP-250 (CNS007)
• Density KIT for solids and liquids (CNS002)
TSI models equipped with integrated • Serial to USB converter (CNS1002)
Ioniser on the back of the balance. • Serial cable for serial output to printer or PC (CNS743)
The ioniser has two way of operating: • Stylus pen for touchscreen (CNS021)
2 minutes or continuosily for max 8 • Factory Calibration certificate (CNS0333)
hours.
Main functions page for easy working Easy selection for density function
Live color indication for check weighing Main page with easy access to the menus
11
TS SERIES - Resolution 0,001g - 0,01g - 0,1g Precision Balances
(1) (2)
N S - + % ₹ A
EM-FR LC-HR USB PASSWORD TOUCH DATABASE RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK GLP LANG RECIPE TEXTILE UNDER
12
Balance technical data
• Span drift (+ 10...+ 30 °C): +/– 2ppm/°C
• Dimensions LxWxH (mm): 345x215x345
• Weighing chamber diameter-Height (mm)
0,001g res. models: 150x70
• Power supply M models 110-230Vac, 50/60Hz;
output 24V 500mA 13VA
• Power supply L models 110-230Vac, 50/60Hz;
output 9V 1,2A 10VA
• Net Weight: 6,7 Kg
Accessories
• Portable ioniser Ion-A15 (CNS0371)
• Serial Printer TLP-50, with date/time (CNS054)
• Serial Printer DPP-250 (CNS007)
• Density KIT for solids and liquids (CNS002) 0,001g res.
• Density KIT for solids and liquids (CNS004) 0,01/0,1g res.
• Serial to USB converter (CNS1002)
• Serial cable for serial output to printer or PC (CNS743)
• Stylus pen for touchscreen (CNS021)
• Factory Calibration certificate (CNS0333)
Main page with easy access to the menus Qwerty touch keypad for easy input
13
SM SERIES - Resolution 0,01mg SemiMicro Balances
I-Model
ION
IONISER
Accessories
• Ioniser Ion-A15 (CNS0371)
• Serial Printer TLP-50, with date/time (CNS054)
• Serial Printer DPP-250 (CNS007)
• Density KIT for solids and liquids (CNS002)
• Serial to USB converter (CNS1002)
• Serial cable for serial output to printer or PC (CNS743)
• Calibration certificate (CNS0333)
14
SMG SERIES - Resolution 0,01mg SemiMicro Balances
I-Model
ION
IONISER
N S
EM-FR RS 232 UNITS PCS I- models equipped with integrated Ioniser on the
%
back of the balance. The ioniser has two way of
- + ₹ A
06.05.17
15
A SERIES - Resolution 0,0001g Analytical Balances
ION
IONISER
16
AG SERIES - Resolution 0,0001g Analytical Balances
I Model
ION
IONISER
N S - +
EM-FR RS 232 UNITS PCS LIMITS
% ₹ A
I- models are equipped with integrated Ioniser on
06.05.17
0.000000
the back of the balance. The ioniser has two way of
% WEIGH ADD ANIMAL DENSITY PEAK GLP CLOCK LANG RECIPE GRAPHIC operating: 2 minutes or continuosily for max 8 hours.
17
B SERIES - Resolution 0,0001g Analytical Balances
I Model
ION
IONISER
(1)
(1)
To order Verification please
add -M to name, e.g. B214Ai-M
18
BG SERIES - Resolution 0,0001g Analytical Balances
I Model
ION
IONISER
N S
EM-FR RS 232 UNITS PCS
(1)
- + % ₹ A
I- models equipped with integrated Ioniser on the back
06.05.17
0.000000
of the balance. The ioniser has two way of operating:
LIMITS % WEIGH ADD ANIMAL DENSITY PEAK GLP CLOCK LANG RECIPE VERIFIED GRAPHIC 2 minutes or continuosily for max 8 hours.
Features
• Electromagnetic force restoration weighing
system
• External or automatic internal calibration
• LCD with backlight with adjustable contrast
• Round glass windshield
• Plastic protection cover
• Under hook weighing (1)
(2)
N S - + % (1)
0.000000
EM-FR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK UNDER STAT LCD VERIFIED
(2)
To order Verification please
(1)
Not available for verified models
add -M to name, e.g. B214Ai-M
20
CH SERIES - Resolution 0,001g Precision Balances
Features
• Electromagnetic force restoration weighing
system
• External or automatic internal calibration
• LCD with backlight with adjustable contrast
• Large glass draught shield with 3 sliding
doors for easy access to the items being
weighed
• Plastic protection cover
• Under hook weighing (1)
(2)
N S - + % 0.000000
EM-FR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK UNDER STAT LCD VERIFIED
Accessories
• Ioniser Ion-A15 (CNS0371)
• Serial Printer TLP-50, with date/time (CNS054)
• Serial Printer DPP-250 (CNS007)
• Density KIT for solids and liquids (CNS002)
• Serial to USB converter (CNS1002)
• Serial cable for output to printer/PC (CNS743)
• Calibration certificate (CNS0333)
• Conformity Declaration (Verification(2))
• Comunication KIT for balances (CNS0476)
(2)
To order Verification please add
-M to name, e.g. B214Ai-M
21
CG SERIES - Resolution 0,001g Precision Balances
(2)
N S - + % ₹ A
(1) 06.05.17
0.000000
EM-FR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK GLP CLOCK LANG RECIPE UNDER VERIFIED GRAPHIC
(2)
To order Verification please
(1)
Not available for verified models
add -M to name, e.g. B214Ai-M
22
CGH SERIES - Resolution 0,001g Precision Balances
(2)
N S - + % ₹ A
06.05.17
0.000000
EM-FR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK GLP CLOCK LANG RECIPE UNDER VERIFIED GRAPHIC
Accessories
• Ioniser Ion-A15 (CNS0371)
• Serial Printer TLP-50, with date/time (CNS054)
• Serial Printer DPP-250 (CNS007)
• Density KIT for solids and liquids (CNS002)
• Serial to USB converter (CNS1002)
• Serial cable for serial output to printer or PC
(CNS743)
• Calibration certificate (CNS0333)
• Conformity Declaration (Verification(2))
(2)
To order Verification please add
-M to name, e.g. B214Ai-M
23
D SERIES - Resolution 0,01g Precision Balances
Features
• Electromagnetic force restoration weighing
system
• External or automatic internal calibration
• LCD with backlight with adjustable contrast
• Plastic protection cover
• Under hook weighing (1)
• PQ models have a rectangular pan
175x195mm
%
(2)
(1)
N S - + 0.000000
EM-FR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK UNDER STAT LCD VERIFIED
(2)
To order Verification please
(1)
Not available for verified models
add -M to name, e.g. B214Ai-M
24
DG SERIES - Resolution 0,01g Precision Balances
Features
• Electromagnetic force restoration weighing
system
• External or automatic internal calibration
• Recipe database: 99 recipes can be stored,
each with up to 20 ingredients
• Large Graphic display allows efficient and
easy operations
• Multilanguage: EN-DE-FR-IT-ES-PT
• GLP/ISO record keeping of weight values
with date, time and serial number
• Plastic protection cover
• Under hook weighing (1)
• PQ models have a rectangular pan
175x195mm
(2)
N S - + % ₹ A
(1)
06.05.17
0.000000
EM-FR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK GLP CLOCK LANG RECIPE UNDER VERIFIED GRAPHIC
(2)
To order Verification please add
(1)
Not available for verified models
-M to name, e.g. B214Ai-M
25
E SERIES - Resolution 0,001g Precision Balances
Features
• High resolution load cell weighing system
• External or automatic internal calibration
• LCD with backlight with adjustable contrast
• Round glass windshield
• Plastic protection cover
• Under hook weighing (1)
(2)
- + % (1)
0.000000
LC-HR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK UNDER ACCU STAT LCD
(1)
Only for external calibration (2)
Optional external battery pack
model (CNS015)
26
EH SERIES - Resolution 0,001g Precision Balances
Features
• Large glass draught shield with 3 sliding
doors for easy access to the items
• High resolution load cell weighing system
• External or automatic internal calibration
• LCD with backlight with adjustable contrast
• Plastic protection cover
• Under hook weighing (1)
(2)
- + % 0.000000
LC-HR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK UNDER ACCU STAT LCD
Accessories
• Ioniser Ion-A15 (CNS0371)
• Serial Printer TLP-50, with date/time (CNS054)
• Serial Printer DPP-250 (CNS007)
• Portable rechargeable battery pack (CNS015)
• Density KIT for solids and liquids (CNS002)
• Serial to USB converter (CNS1002)
• Serial cable for serial output to printer or PC (CNS743)
• Calibration certificate (CNS0333)
• Comunication KIT for balances (CNS0476)
(2)
Optional external battery pack
(CNS015)
27
EG SERIES - Resolution 0,001g Precision Balances
Features
• High resolution load cell weighing system
• External or automatic internal calibration
• Recipe database: 99 recipes can be stored,
each with up to 20 ingredients
• Large Graphic display allows efficient and
easy operations
• Multilanguage: EN-DE-FR-IT-ES-PT
• GLP/ISO record keeping of weight values
with date, time and serial number
• Round glass windshield
• Plastic protection cover
• Under hook weighing (1)
(2)
- + % ₹ A
06.05.17
0.000000
LC-HR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK GLP CLOCK LANG RECIPE UNDER ACCU GRAPHIC
Accessories
• Ioniser Ion-A15 (CNS0371)
• Serial Printer TLP-50, with date/time (CNS054)
• Serial Printer DPP-250 (CNS007)
• Density KIT for solids and liquids (CNS002)
• Portable rechargeable battery pack (CNS015)
• Serial to USB converter (CNS1002)
• Serial cable for serial output to printer or PC
(CNS743)
• Calibration certificate (CNS0333)
(2)
Optional external battery pack
(CNS015)
28
EGH SERIES - Resolution 0,001g Precision Balances
Features
• Large glass draught shield with 3 sliding
doors for easy access to the items
• High resolution load cell weighing system
• External or automatic internal calibration
• Recipe database: 99 recipes can be stored,
each with up to 20 ingredients
• Large Graphic display allows efficient and
easy operations
• Multilanguage: EN-DE-FR-IT-ES-PT
• GLP/ISO record keeping of weight values
with date, time and serial number
• Plastic protection cover
• Under hook weighing (1)
(2)
- + % ₹ A
06.05.17
0.000000
LC-HR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK GLP CLOCK LANG RECIPE UNDER ACCU GRAPHIC
Accessories
• Ioniser Ion-A15 (CNS0371)
• Serial Printer TLP-50, with date/time (CNS054)
• Serial Printer DPP-250 (CNS007)
• Density KIT for solids and liquids (CNS002)
• Portable rechargeable battery pack (CNS015)
• Serial to USB converter (CNS1002)
• Serial cable for serial output to printer or PC
(CNS743)
• Calibration certificate (CNS0333)
• Comunication KIT for balances (CNS0476)
(2)
Optional external battery pack
(CNS015)
29
F SERIES - Resolution 0,01g Precision Balances
Features
• High resolution load cell weighing system
• External or automatic internal calibration
• LCD with backlight with adjustable contrast
• Plastic protection cover
• Under hook weighing (1)
(4) (2)
- + % (3)
(1)
0.000000
LC-HR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK UNDER ACCU STAT LCD VERIFIED
Accessories
Capacity Resolution Response Verification
Model Pan (mm) Repeatibility (g) Linearity (g)
(g) (g) time (sec.) (optional(2))M
• Ioniser Ion-A15 (CNS0371) F1002i 1000 0,01 Ø 160 0,01 ± 0,02 ≤3 M
• Serial Printer TLP-50, with date/time (CNS054)
• Serial Printer DPP-250 (CNS007) F2202i 2200 0,01 Ø 160 0,01 ± 0,03 ≤3 M
• Portable rechargeable battery pack (CNS015) F3202i 3200 0,01 Ø 160 0,01 ± 0,03 ≤3 M
• Density KIT for solids and liquids (CNS004)
F4202i 4200 0,01 Ø 160 0,01 ± 0,04 ≤4 –
• Serial to USB converter (CNS1002)
• Serial cable for serial output to printer or PC (CNS743)
• Calibration certificate (CNS0333) Only Verified (M) Version
• Conformity Declaration (Verification(2))
Capacity Resolution Response
• Comunication KIT for balances (CNS0476) Model Pan (mm) Repeatibility (g) Linearity (g)
(g) (g) time (sec.)
F3102i-M 3100 0,01 Ø 160 0,01 ± 0,03 ≤3
(3)
Only for external calibration
(1)
Not available for verified models
model
(2)
To order Verification please (4)
Optional external battery pack
add -M to name, e.g. F1002i-M (CNS015)
30
FG SERIES - Resolution 0,01g Precision Balances
(4) (2)
- + % ₹ A
06.05.17
(3) 0.000000
(1)
LC-HR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK GLP CLOCK LANG RECIPE UNDER ACCU GRAPHIC VERIFIED
Features
• High resolution load cell weighing system
• External calibration
• LCD with backlight with adjustable contrast
• Plastic protection cover
• Under hook weighing
%
(1) (2)
- + 0.000000
LC-HR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK UNDER ACCU STAT LCD
Accessories
• Serial Printer TLP-50, with date/time (CNS054)
• Serial Printer DPP-250 (CNS007)
• Portable rechargeable battery pack (CNS015)
• Serial to USB converter (CNS1002)
• Serial cable for serial output to printer or PC (CNS743)
• Calibration certificate (CNS0333)
• Comunication KIT for balances (CNS0476)
(1)
Optional external battery pack
(CNS015)
32
GG SERIES - Resolution 0,1g Precision Balances
Features
• Large Graphic display allows efficient and
easy operations
• High resolution load cell weighing system
• External calibration
• Recipe database: 99 recipes can be stored,
each with up to 20 ingredients
• Multilanguage: EN-DE-FR-IT-ES-PT
• GLP/ISO record keeping of weight values
with date, time and serial number
• Plastic protection cover
• Under hook weighing
%
(1)
- +
06.05.17
₹ A 0.000000
LC-HR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK GLP CLOCK LANG RECIPE UNDER ACCU GRAPHIC
Accessories
• Serial Printer TLP-50, with date/time (CNS054)
• Serial Printer DPP-250 (CNS007)
• Portable rechargeable battery pack (CNS015)
• Serial to USB converter (CNS1002)
• Serial cable for serial output to printer or PC
(CNS743)
• Calibration certificate (CNS0333)
(1)
Optional external battery pack
(CNS015)
33
H SERIES - Resolution 0,001g Precision Balances
Features
• High resolution load cell weighing system
• Small footprint
• External calibration
• LCD with backlight with adjustable contrast
• Round glass windshield
• Plastic protection cover
%
(1)
- + 0.000000
LC-HR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK ACCU STAT LCD
Accessories
• Ioniser Ion-A15 (CNS0371)
• Serial Printer TLP-50, with date/time (CNS054)
• Serial Printer DPP-250 (CNS007)
• Density KIT for solids and liquids (CNS002)
• Serial to USB converter (CNS1002)
• Serial cable for serial output to printer or PC (CNS743)
• Calibration certificate (CNS0333)
• Comunication KIT for balances (CNS0476)
• Rechargeable battery pack external (CNS015)
(1)
Optional external battery pack
(CNS015)
34
I SERIES - Resolution 0,01g Precision Balances
Features
• High resolution load cell weighing system
• Small footprint
• External calibration
• LCD with backlight with adjustable contrast
• Under hook weighing
• Plastic protection cover
%
(1) (2)
- + 0.000000
LC-HR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK UNDER ACCU STAT LCD
Accessories
• Ioniser Ion-A15 (CNS0371)
• Serial Printer TLP-50, with date/time (CNS054)
• Serial Printer DPP-250 (CNS007)
• Density KIT for solids and liquids (CNS004)
• Serial to USB converter (CNS1002)
• Serial cable for serial output to printer or PC (CNS743)
• Calibration certificate (CNS0333)
• Comunication KIT for balances (CNS0476)
• Rechargeable battery pack external (CNS015)
(1)
Optional external battery pack
(CNS015)
35
L SERIES - Resolution 0,1g Precision Balances
Features
• High resolution load cell weighing system
• Small footprint
• External calibration
• LCD with backlight with adjustable contrast
• Under hook weighing
• Plastic protection cover
%
(1) (2)
- + 0.000000
LC-HR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK UNDER ACCU STAT LCD
• Power supply 110-230Vac, 50/60Hz; L3201 3200 0,1 150x140 0,05 ± 0,2 ≤2
output 9V 1,2A 10VA L5201 5200 0,1 150x140 0,05 ± 0,2 ≤2
• Net Weight: 1,4Kg L6501 6500 0,1 150x140 0,05 ± 0,2 ≤2
Accessories
• Serial Printer TLP-50, with date/time (CNS054)
• Serial Printer DPP-250 (CNS007)
• Serial to USB converter (CNS1002)
• Serial cable for serial output to printer or PC (CNS743)
• Calibration certificate (CNS0333)
• Comunication KIT for balances (CNS0476)
• Rechargeable battery pack external (CNS015
• Density KIT for solids and liquids (CNS004)
(1)
Optional external battery pack
(CNS015)
36
M SERIES - Resolution 0,01g-0,1g Precision Balances
Features
• High resolution load cell weighing system
• Small footprint, portable
• External calibration
• LCD with backlight
• Operates also with AA batteries (not
included)
• Plastic protection cover
(1)
%
5
- + AA
0.000000
Accessories
• Calibration certificate (CNS0333)
(1)
Optional external battery pack
(CNS015)
37
TS-HC SERIES - Resolution 0,01g - 0,1g - 0,5g - 1g High Capacity
Main features
• Electromagnetic force restoration weighing
system (for 0,01g resolution)
• High readability load cell weighing system
(for 0,1g resolution)
• External calibration
• Large 5’’ color touchscreen 800x480 display
• Selectable and customizables measuring units
• Internal Database
• GLP/ISO record of last stored calibration data
• Multi Languages (EN-DE-FR-IT-SP-PT)
• Multi-user with password protection
• USB port for import/export database data
• RS232 serial interface
• Advanced piececounting function with Sta-
tistcs report
• Textile function to measure fibers with Sta-
tistics report
• Formulation (Recipe)
• Checkweighing
%
(1)
- + • Percentual weighing
• Weights adding
• Animal weighing
LC-HR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK UNDER ACCU STAT TOUCH DATABASE
External Calibration
Technical data
Resolution Response
• Span drift (+ 10...+ 30 °C): +/- 6ppm/°C Model Capacity (g)
(g)
Pan (mm) Repeatibility (g) Linearity (g)
time (sec.)
• Dimensions LxWxH (mm): 360x355x130 TS-HC8001 8000 0,1 320x220 0,05 ± 0,2 ≤3
• Power supply 110-230Vac, 50/60Hz;
TS-HC16001 16000 0,1 320x220 0,05 ± 0,3 ≤3
output 9V 1,2A 10VA
• Power supply 110-230Vac, 50/60Hz; TS-HC25001 25000 0,1 320x220 0,1 ± 0,3 ≤4
output 24V 1A 13VA (0,01g res) TS-HC32001 32000 0,1 320x220 0,1 ± 0,4 ≤4
• Net Weight: 8Kg (0,01 res), 7,5 kg TS-HC32001.5 32000 0,5 320x220 0,5 ± 0,4 ≤3
TS-HC32000 32000 1 320x220 0,5 ±1 ≤3
TS-HC32001D 4500/32000 0,1/1 320x220 0,05/0,5 ± 0,2/ ± 1 ≤3
(1)
Optional external battery pack
(only for 9V models) (CNS015)
38
High Capacity
Features
• Electromagnetic force restoration weighing
system (for 0,01g resolution)
• High readability load cell weighing system
(for 0,1g resolution)
• Dot Matrix graphical display
• External calibration
• GLP/ISO record of last stored calibration
data
• Multi Languages (EN-DE-FR-IT-SP-PT)
• RS232 serial interface
• Formulation (Recipe)
• Checkweighing
• Percentual weighing
• Weights adding
• Animal weighing
• Max load determination (Peak hold)
• Plastic protection cover
• Under hook weighing
%
(1)
- +
06.05.17
0.000000
LC-HR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK UNDER ACCU STAT GRAPHIC
Technical data
• Span drift (+ 10...+ 30 °C): +/- 6ppm/°C
• Dimensions LxWxH (mm): 360x355x130
External Calibration • Power supply 110-230Vac, 50/60Hz;
Resolution Response output 9V 1,2A 10VA
Model Capacity (g) Pan (mm) Repeatibility (g) Linearity (g)
(g) time (sec.) • Power supply 110-230Vac, 50/60Hz;
HCG8001 8000 0,1 320x220 0,05 ± 0,2 ≤3 output 24V 1A 13VA (0,01g res)
HCG16001 16000 0,1 320x220 0,05 ± 0,3 ≤3 • Net Weight: 8Kg (0,01 res), 7,5 kg
HCG25001 25000 0,1 320x220 0,1 ± 0,3 ≤4
HCG32001 32000 0,1 320x220 0,1 ± 0,4 ≤4
HCG32001.5 32000 0,5 320x220 0,5 ± 0,4 ≤3
HCG32000 32000 1 320x220 0,5 ±1 ≤3
HCG32001D 4500/32000 0,1/1 320x220 0,05/0,5 ± 0,2/ ± 1 ≤3
Accessories
• Ioniser Ion-A15 (CNS0371)
HCG6202 6200 0,01 195x175 0,01 ± 0,03 ≤4
• Serial Printer TLP-50, with date/time (CNS054)
HCG8202 8200 0,01 195x175 0,01 ± 0,03 ≤4 • Serial Printer DPP-250 (CNS007)
HCG10102 10100 0,01 195x175 0,01 ± 0,03 ≤4 • PC data collection software (CNS0476)
• Serial to USB converter (CNS1002)
HCG12102 12100 0,01 195x175 0,01 ± 0,03 ≤4 • Serial cable for serial output to printer or PC
(CNS743)
• Portable rechargeable battery pack (CNS015)
• Factory Calibration certificate (CNS0333)
(1)
Optional external battery pack
(only for 9V models) (CNS015)
39
HC SERIES - Resolution 0,01g - 0,1g - 0,5g - 1g High Capacity
Features
• Electromagnetic force restoration weighing
system (for 0,01g resolution)
• High readability load cell weighing system
(for 0,1g resolution)
• External calibration
• LCD with backlight with adjustable contrast
• Plastic protection cover
• Under hook weighing
%
(1)
- + 0.000000
LC-HR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK UNDER ACCU STAT LCD
(1)
Optional external battery pack
(CNS015)
40
TG SERIES - Resolution 0,0001g-0,001g-0,01g Moisture Analyzers
(2)
N S
EM-FR LC-HR RS 232 UNITS GLP CLOCK DATABASE MODES TOUCH USB GRAPH PASSWORD
Accessories
• Thermometer calibration KIT (CNS02)
• Serial Printer TLP-50, with date/time (CNS054)
• TEST pans (Ø 100mm x 0,5mm) (CNS753)
• Ioniser Ion-A15 (CNS0371)
• Calibration certificate (CNS0333)
• Touchscreen Stylus pen (CNS021)
• Fiber glass test panz Ø 90 (CNS026)
41
Moisture Analyzers
Features
• Electromagnetic force restoration weighing
system (A64M and 163M)
• High resolution load cell weighing system
(163L and 62L)
• Halogen-infrared lamp
Export/import • External calibration
results • Large 5’’ color touchscreen 800x480 display
and database to • RS232 serial interface
USB • Drying resolution 0,001% (-A64M), 0,01%
(-163M and -163L), 0,1% (-62L)
• Drying modes:Time mode (1-99 min.),
Autostop % or absolute autostop in grams,
Manual
• Live Graph of humidty content changing
• Temperature range: 35-160°C, step of 1°C
• Temperature Profiles: Standard, fast, mild,
steps
• Results in: Humidity%, Dry residue%,
ATRO%, Weight
• Test results complete of full drying cycle
Graph
• Up to 10 hot keys for fast recall of drying
cycles from internal database
• Default database stored already with more
than 30 products
• Saving results with test reports and drying
graphic up to 300 records, for each user.
• Customizable settings for up to 10 users
with the possibility of password protection.
• Serial output for connection to printer, USB
port for export or import database, test
results, etc.
Main functions page for easy working Live color indication for check weighing
Manual tare input Clear and easy input for GLP function
42
T GRAPHIC SERIES - Resolution 0,0001g-0,001g-0,01g
The new T GRAPHIC - Series are rugged
instruments for moisture determination of
raw materials and finished samples in the
food, cosmetics, ceramics, agriculture and
construction industry.
The Dot Matrix graphical display with backlite
makes much easier and friendly using the
instrument and gives easy and intuitive
guidance through the operating process
thanks also to his advanced software. On
the display are shown all the parameters
regarding the drying process and all the
relative results, all viewable at once.
This instrument brings features such as one
key pressing for starting automatically the
last drying cycle memorized or the default
one, possibility to print the drying session by
interval time set by the user, automatic session
starting just by closing the heater etc...
Drying readability are 0,001%, 0,01% and
0,1%. Possibility of calibrating the internal
thermometer (with optional KIT CNS02).
N S ₹ A
06.05.17
0.000000
External Calibration
Technical data
Capacity Resolution Moisture Repeatibility Precision Response
Model
(g) (g) Resolution
Pan (mm)
(g)
Linearity (g)
(2g) time (sec.)
• Span drift (+ 10...+ 30 °C): +/- 3ppm/°C
[TA64MG]; +/- 4ppm/°C [other models]
100mm • Dimensions LxWxH (mm): 345x215x235
TA64MG 60 0,0001 0,001% 0,0001 ± 0,0003 0,18% ≤3
Samples Pan
• Maximum dimension of container on the
pan: 100mm (Ø) x 25mm (height)
100mm
T203MG 200 0,001 0,01% 0,001 ± 0,003 0,18% ≤3 • Power supply: AC 220-240 V (at request
Samples Pan
AC 110 Volt) 50/60Hz; plugs EU,UK
100mm • Heater: 230V AC 50/60Hz, 400Watt
T163LG 160 0,001 0,01% 0,001 ± 0,003 0,20% ≤4
Samples Pan • Net Weight: 6,1Kg (TA64MG and
T163MG)
100mm
T62LG 60 0,01 0,1% 0,01 ± 0,03 0,50% ≤3
Samples Pan
Accessories
• Portable ioniser Ion-A15 (CNS0371)
• Thermometer calibration KIT (CNS02)
• Serial Printer TLP-50, with date/time (CNS054)
• Serial Printer DPP-250 (CNS007)
• Serial to USB converter (CNS1002)
• Serial cable for output to printer/PC (CNS743)
• Test pans (Ø 100mm x 0,5mm) (CNS753)
• Fiber glass test pans Ø 90mm (CNS026)
• Factory Calibration certificate (CNS0333)
43
Moisture Analyzers
Features
• Electromagnetic force restoration weighing
system (TA64MG and T163MG)
• High readability load cell weighing system
(T163LG and T62LG)
• Halogen-infrared lamp
• Large Graphic display allows efficient and
easy operations
• Date and time indication
• Multilanguage: EN-DE-FR-IT-ES-PT
• GLP/ISO record of last stored calibration
data
• Two heating modes: standard and rapid
• Pre-heating on/off
• Time (1-99 min) and Autostop operating
modes
• Temperature range: 35-160°C/1°C
• Moisture, dry residue in percentage and
ATRO indications
• RS232 serial interface
• View and print the moisture analyzer and
heater’s last stored calibraion data
• Measuring unit g or mg
• Automatic starting of sessions by closing
the heater
• Plastic protection cover
Easy set up of the heater parameters Moisture analyzer calibration data overview
All the parameters all visible at once during Clear and detailed results view
drying session
44
TS-iDens - Balance for Density Index
TS-iDens is a Balance for density calculation,
in particular it is designed to easily determine
the Density Index of a solid sample without
need of any computer software or external
database.
All-in-one product
With TS-iDens, calculating the density index
is easy and fast. Without the necessity to
connect the balance to computer for using
a specific software, all the data and results
can be seen directly in the large screen of the
balance, with the possibility to print also all
the data with an optional printer.
Database
As reference liquid for the density
etermination of the solid sample, the balance
has already stored in the database the density
values (at different temperatures) of distilled
water or Ethanol so that one less thing for the
user to care about; of course the user can use
whatever other liquid as reference, provided
its density value is known or calculated (thanks
to the optional liquid density kit).
N S ₹ A
Density values of the reference liquid (distilled
EM-FR RS 232 UNITS GLP DATABASE USB PASSWORD DENSITY LANG
water or Ethanol) used during density
etermination of the solid sample are stored
in the internal database. The user can choose
Automatic internal calibration another liquid as reference, provided its
density value is known or he calculates (thanks
Capacity Resolution Pan Repeatibility Linearity Response
Model
(g) (g) (mm) (g) (g) time (sec.)
to the optional liquid density kit).
46
JW SERIES - Resolution 0,001ct / 0,001g-0,01g Jewelry Balances
Features
• Electromagnetic force restoration weighing
system
• External or automatic internal calibration
• g/ct swapping button on keypad
• Glass draught shield with 3 sliding doors for
easy access to the items being weighed
• 0,01 resolution models are not provided
with glass draught shield
• Plastic protection cover
N S - + % 0.000000
EM-FR RS 232 UNITS PCS LIMITS % WEIGH ADD ANIMAL DENSITY PEAK UNDER LCD
Response
Model Capacity Resolution Pan (mm) Repeatibility Linearity
time (sec.) Technical data
• Dimensions LxWxH (mm): 345x215x290
Carat series - Automatic internal calibration (models 0,1mg and 1mg)
JW124Ai 600ct/120g 0,001ct Ø 80 0,001ct ± 0,003ct ≤4 • Weighing chamber LxWxH (mm):
162x171x170 (models 0,1mg and 1mg)
JW214Ai 1050ct/220g 0,001ct Ø 80 0,001ct ± 0,003ct ≤4
• Dimensions LxWxH (mm): 345x215x100
Gold series - Automatic internal calibration (models 0,01g)
JW723i 720g 0,001g Ø 110 0,001g ± 0,002g ≤2 • Power supply 110-230Vac, 50/60Hz;
JW4202i 4200g 0,01g Ø 160 0,01g ± 0,04g ≤2
output 24V 500mA 13VA
Accessories
• Portable ioniser Ion-A15 (CNS0371)
• Serial Printer TLP-50, with date/time (CNS054)
• Serial Printer DPP-250 (CNS007)
• Serial to USB converter (CNS1002)
• Serial cable for serial output to printer or PC
(CNS743)
• Factory Calibration certificate (CNS0333)
47
PT Series - Complete system for pipette checking
Pipettes are widely used instruments in
laboratories and their proper maintenance
is essential to ensure correct and reliable
results. Each laboratory should establish
a regular verification program, in order to
carry out their preventive maintenance or (re)
calibration, if necessary.
Pipette check
This series of balances is designed for the ver-
ification of piston pipettes using the gravimet-
ric method.
The embedded “Pipette Check” software al-
lows you to test the correct operation of a pi-
pette by selecting a verification method.
At the end, a detailed report is generated with
the overall test result (compliant or not-com-
pliant pipette) and the relative partial values.
Main features:
• 5 inch color touch-screen display (800x480)
• Draftshield with 3 sliding doors
• RS232 serial output
• Selectable measuring units
• On-board Software functions: Pipette Check, Piece counting, Check weighing, Percentage weighing, Statistics,
Animal weighing, Peak hold, Density determination, Recipe, Textile
• Multi-user with password protection, Multi-language
• GLP protocol
• Internal Database
• USB port to import/export data of database
Verification methods:
• ISO8655
• 4x (100% 10%): 4 samples at 100% and 10% of the nominal volume
• 4x (100%): 4 samples at 100% of the nominal volume
• Custom: number of samples and percentage of the volume of your choice
48
PT - Complete system for pipette checking
ISO8655 compliance
It is possible to identify whether a pipette needs maintenance or (re)
calibration by assessing its performance according to the specifications
given by the ISO8655 directive, which describes exactly the procedure
and the results that must be obtained to consider a pipette compliant.
The messages on the balance’s screen guide the user through the
required steps to carry out the test in complete compliance with the
requirements of the directive.
Verification methods
Customized control methods can also be defined: the volumes to be
checked and the number of samples can be entirely defined by the
user. Two predefined methods are available: 100% and 10% volume
test with 4 samples each or only 100% volume test with 4 samples.
Internal laboratory procedures can use these control methods for
faster daily checks.
However, the balances of this series can always be used for normal laboratory weighing operations; in the case of -PT models, the evaporation
trap is easily removable.
49
ACCESSORIES
CNS007
Portable thermal printer DPP-250 (cable version)
DPP-250 and printer is a small footprint portable printer that can be used with OPTIKA laboratory balances.
Weight values are printed quickly and sharply. The internal rechargeable battery grants mobility.
Printer DPP-250 is supplied with connection cable to be connected directly to OPTIKA balances.
CNS030
Dot-matrix serial printer
TX-110 is a high-speed dot-matrix printer suitable for long-term data retention. It is compliant with ISO/
GLP procedures, it is equipped with a bright OLED display and has various operating modes:
Features:
• DIRECT. Prints out current weight value
• TARE/NET/GROSS. Prints out these values separately
• SUM. Prints out the total value of samples
• AVERAGE. Prints out the average of samples
• FORMULATION. Print out each sample’s weight independently when mixing samples
• PIPETTE CALIBRATION. Calibrate capacity of pipette
• USER DEFINED. Operator can set a multiplicative coefficient
• COMPARATOR. Prints out weight value only when inside a defined range
• AUTOMATIC TIMING. Prints out weight value at defined time intervals
50
ACCESSORIES
CNS054
Line thermal dot printer TLP-50
TLP-50 printer is a compact printer that can be used with OPTIKA laboratory balances.
This printer has internal clock so it can print date/time together with weight values. Paper type is label.
CNS010-CNS011-CNS012-CNS031
CODE MODEL
CNS010 Roll of 54x24mm labels (500) for CNS054
51
ACCESSORIES
CNS027
Draft Shield rear panel with integrated ioniser
To neutralize static charges on samples to weigh.
The user can easily and quickly mount this panel on a balance already in his possession, upgrading the
balance with an integrated ioniser. The ioniser is easily activated by pressing a button.
There are two ways of operating: 2 minutes or continuously for max 8 hours.
Includes:
rear panel with integrated ioniser, power supply.
CNS0371
Ioniser model ION-A15, for all balances
Static charges accumulate in many kind of samples that are being weighed during the laboratory routine.
By blowing ions, the portable Ionizer ION-A15 neutralizes static electricity on charged samples like plastic
parts, containers or films. Within seconds the sample is ready to be weighted free from static charges
giving the operator accurate results.
The Ionizer ION-A15 is small and light, easy to transport and use everywhere in the laboratory.
Weight 310 g
CNS02
Thermometer calibration KIT
Small, fast-response thermometer for verify and calibrate the heating source of OPTIKA
moisture Analyzers T Series & TG Series. A calibrated moisture analyzer’s heater allows to have
always accurate results. Essential for application where are required certified results.
Resolution 1°C
Precision +/-2°C
Diameter Ø 46 mm
52
ACCESSORIES
CNS0476
Comunication KIT for balances
Complete kit to connect OPTIKA balances to a computer. It allows data collection, Statistics, creation of
graphs and export results to Excel file.
The software included allows to perform all the functions of the balance from the PC such as Piececount,
Density, Peak hold, Limits set etc...from your computer.
CNS015
Portable rechargeable battery pack
Portable Li-Ion rechargeable battery pack. Can connect and power balances for outdoor use or for
enhance the portability of the balance.
Input 9/12V
Battery duration 40 hours about (depends on use and on the device connected)
Capacity 10000mAh/37Wh
Dimensions 120x80x23mm
Weight 304g
It contains:
2 Glass graduated Beaker: height 150mm Ø 50mm 250ml and height 95mm Ø 65 mm 250ml
Glass Plummet
53
ACCESSORIES
CNS753
Aluminum Test pans for moisture analyzers
Aluminium sample dishes are essential for using with moisture analyzers.
Reusable, diameter 100mm, thickness 0.5mm.
One box contains 80 pans.
CNS026
Glass fiber discs for moisture analyzers
Glass fibre discs are used when analysing liquids and semi solid samples.
They are used in conjunction with the aluminium test disc code CNS753 (see photo on left).
It ensures accurate results when testing samples that contain large amounts of liquid and
prevent liquid splashing during the sample drying process.
It also facilitate a better distribution of heat throughout the sample.
Diameter 90mm.
One box contains 200 discs.
CNS1002 - CNS743
Comunication cables
CODE MODEL
CNS1002 RS232/USB converter balance/PC
CNS743 Serial cable 9pins M/M for serial output printer/PC
Protection cover
Protection covers replacement are available on request for all the models.
54
ACCESSORIES
CALIBRATION WEIGHTS
55
Distributor