0% found this document useful (0 votes)
25 views14 pages

Characteristics Series CE, CP, C

The document provides detailed specifications for 2-way slip-in cartridge valves from the Series CE, CP, and C, designed for hydraulic control and compact installation. It outlines features such as installation patterns, poppet shapes, spring options, and the various combinations available for directional and pressure functions. Additionally, it includes ordering codes, dimensions, and technical data for performance and compatibility with hydraulic systems.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
25 views14 pages

Characteristics Series CE, CP, C

The document provides detailed specifications for 2-way slip-in cartridge valves from the Series CE, CP, and C, designed for hydraulic control and compact installation. It outlines features such as installation patterns, poppet shapes, spring options, and the various combinations available for directional and pressure functions. Additionally, it includes ordering codes, dimensions, and technical data for performance and compatibility with hydraulic systems.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 14

Catalogue MSG11-3500/UK 2-Way Slip-In Cartridge Valves

Characteristics Series CE, CP, C

2-way slip-in cartridge valves are hydraulically controlled


seat valves that are designed for compact block installa-
tion. Slip-in cartridge, cover, and pilot system are valve
elements that permit single and combined functions.
Series CE offers poppet and sleeve combinations for
directional functions. Series CP offers a cartridge for
pressure functions and has to be combined with cor-
responding covers.

Features
CE C*B
• Installation cavity and mounting pattern according to
ISO 7368
• 5 poppet shapes
• 5 poppet springs
• Optional seal between ports B and C
• Cover with adjustable stroke limitation
• Cover with mounting pattern for pilot valve assembly
• Combinations for complex functions
• Normally open cartridge (CE*F*)

C*A C*C

Pilot control for directional functions

C*C
C016C to C040C

8
P A B T
Pilot control valves
for C*C and C*W
have to be ordered
separately
3 1 2 4
X Z1 C Z2 Y
P A B T C050C to C100C
Cover C M
P A B T P A B T
3 1 2 4 3 1 2 4
M
1 1
3 2 1 4
X Z1 C Z2 Y X Z1 C Z2 Y X Z1 C Z2 Y X Z1 C Z2 Y X Z2 C Z1 Y
C*A C*B C*V C*W C*C

Cartridge C C C C
valve CE

normally closed
a B B a B a B
a

A A A A
CE*01 CE*04 CE*07 CE*08 a see ordering code
for details
C C C C

normally open B B B B

A A A A
CE*F01 CE*F04 CE*F07 CE*F08
CE-C UK.INDD 06.01.23

8-4 Parker Hannifin Corporation


Catalogue MSG11-3500/UK 2-Way Slip-In Cartridge Valves
Characteristics Series CE, CP, C

Cartridge valve for directional function


normally closed

1:1 1 : 1.67 1 : 1.04 1 : 1.67


AA = AC AA = 0.6 AC AA = 0.96 AC AA = 0.6 AC
AB = 0.4 AC AB = 0.4 AC
dampening poppet

Normally open

1:1
AA = AC
1 : 1.67
AA = 0.6 AC
1 : 1.04
AA = 0.96 AC
1 : 1.67
AA = 0.6 AC
8
AB = 0.4 AC AB = 0.4 AC
dampening poppet

Cartridge valve for Pilot control for pressure function


pressure function
Pilot control valves
for C*C and C*G
have to be ordered
separately

NG16, 25, 32 NG16, 25, 32 NG40 NG50, 63


P A B T P A B T P A B T
2

2 1 3
3 1 4 3 1 2 4 3 2 1 4
X Z1 C Z2 Y X Z1 C Z2 Y X Z1 C Z2 Y X Z2 C Z1 Y
C*F C*G C*C C*C

1 : 1.04 C
AA = 0.96 AC
Cartridge
normally closed
valve CP
a B

A
Characteristic curves see complete valves pressure function.
CP*07
CE-C UK.INDD 06.01.23

8-5 Parker Hannifin Corporation


Catalogue MSG11-3500/UK 2-Way Slip-In Cartridge Valves
Ordering Code Series CE, CP, C

CE
Cartridge Nominal Design Poppet Spring Orifice Seal Design
size area ratio series
(not required
for ordering)
Code Size
016 NG16 Code Seal
025 NG25 N NBR
032 NG32 V FPM
040 NG40
050 NG50 Code Size Poppet Orifice 4)
063 NG63 without orifice,
99 all all
080 NG80 open
100 NG100 NG16-NG50 01, 04 closed bottom
NG16-NG50 07 plug
00 NG16-NG32 closed bottom
Code Normal position Description 08
NG40-NG50 plug
C Closed No poppet sealing NG63-NG100 all plug
S 1) Closed With poppet sealing
F 2) 3) Open No poppet sealing Code Spring
L Opening pressure 0.1 bar
Code Poppet area ratio N Opening pressure 0.5 bar
01 AA = AC S Opening pressure 1.6 bar
04 AA = 0.6AC, AB = 0.4AC T Opening pressure 2.5 bar
07 3) AA = 0.96AC U Opening pressure 4.0 bar
AA = 0.6AC, AB = 0.4AC
08
with dampening

1) Only for spring S, T and U. Not for poppet code 01 (NG16 to NG63).
2) Only with spring code L, only with closed bottom.
3) Not for NG80 and NG100.

8 4) Orifice size in 1/10 mm, eg. 1.2 mm orifice - code 12. Thread size 1/16 NPTF.

CP 07

Cartridge Nominal Design Poppet Spring Orifice Seal Design


size area ratio series
AA = 0.96AC (not required
for ordering)
Code Size
016 NG16
Code Seal
025 NG25
N NBR
032 NG32
V FPM
040 NG40
050 NG50
Code Orifice 1)
063 NG63
00 Plug
09 0.9 mm for NG16
Code Normal position Description
11 1.1 mm for NG25
C Closed No poppet sealing
12 1.2 mm for NG32
S Closed With poppet sealing
13 1.3 mm for NG40
14 1.4 mm for NG50
Code Spring
15 1.5 mm for NG63
S Opening pressure 1.6 bar
T Opening pressure 2.5 bar
U Opening pressure 4.0 bar For spare parts see "Accessories" in
this chapter.
For orifice recommendations see "Com-
1) Recommended diameter. bination Examples" in this chapter.

CE-C UK.INDD 06.01.23

8-6 Parker Hannifin Corporation


Catalogue MSG11-3500/UK 2-Way Slip-In Cartridge Valves
Technical Data / Performance Curves Series CE, CP

Technical data
General
Design type 2-way slip-in cartridge valves according to ISO 7368
Actuation hydraulic
Mounting position unrestricted
Ambient temperature [C°] -20....+60
MTTFD value [years] 150
Nominal size NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
Weight cartridge [kg] 0.3 0.6 1.1 1.7 3.7 5.5 12.8 27
Hydraulic
Operating pressure slip-in valve [bar] 420
valve cover [bar] 350
port A, B, X, Z1, Z2 [bar] 350
port Y [bar] max. 350 (depending on pmax of pilot valves)
Nominal flow at ∆p 5 bar poppet 01, 04, 07 [l/min] 250 450 900 1350 1800 3600 5250 8000
poppet 08 [l/min] 230 400 800 1250 1625 3400 5000 7500
Pilot volume requirement at poppet 01 [cm3] 2.0 6.5 10.2 17.4 34.5 77.4 190.1 342.6
at poppet 04 2.0 6.5 12.2 20.3 39.4 94.6 190.1 363.4
at poppet 07 2.0 6.5 10.2 17.4 34.5 77.4 — —
at poppet 08 2.0 7.4 15.3 23.2 49.2 111.8 217.3 415.3
Poppet 01 / 07 spring: L = 0.1 N = 0.5 S = 1.6 T = 2.5 U = 4.0
Opening pressure flow direction A → B [bar]
Poppet 04 / 08 spring: L = 0.2 N = 0.9 S = 2.7 T=4 U = 6.6
Poppet 01 / 07 not possible
Opening pressure flow direction B → A [bar]
Poppet 04 / 08 spring: L = 0.3 N = 1.3 S = 4.0 T = 6.3 U = 10.0
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [C°] -20...+70 (NBR: -25...+70)
Viscosity, permitted [mm2/s] 20...400
recommended [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13

Performance curves (without spring and poppet seal, C-chamber unloaded)


Poppet 01, 04, 07 Poppet 08
8

Poppet 01, 04, 07 Poppet 08

All characteristic curves measured with HLP46 at 50 °C.


CE-C UK.INDD 06.01.23

8-7 Parker Hannifin Corporation


Catalogue MSG11-3500/UK 2-Way Slip-In Cartridge Valves
Ordering Code / Dimensions Series C*A, Cover w/o Auxiliary Functions

C A A

Cover Nominal Cover with Without Orifice Seal Design


size X-connection auxilliary series
and gauge function (not required
port G¼" for ordering)
Code Size
Code Seal
016 NG16
N NBR
025 NG25
V FPM
032 NG32
040 NG40
050 NG50 Code Orifice
063 NG63 99 Without orifice, open
080 NG80
M
100 NG100

For orifice recommendations, bolt and seal X Z1 C Z2 Y


kits see "Accessories" in this chapter. Orifice position

Dimensions
NG16 to NG63 NG80 to NG100
Gauge port G¼" Gauge port G¼"
L

8 X Orifice Y X Orifice Y

Z1
Z1
B

X Y X Y

Z2
Z2

B
B

Ports Y, Z1 and Z2: O-ring recess diameter on valve body

Size B L Orifice thread Weight [kg]


NG16 65 36 1/16 NPT 0.9
NG25 85 45 1/16 NPT 1.9
NG32 102 50 1/16 NPT 2.9
NG40 125 60 1/8 NPT 5.3
NG50 140 70 1/8 NPT 8.5
NG63 180 85 1/8 NPT 16.6
NG80 Ø 250 105 1/8 NPT 34
NG100 Ø 300 120 1/8 NPT 58

CE-C UK.INDD 06.01.23

8-8 Parker Hannifin Corporation


Catalogue MSG11-3500/UK 2-Way Slip-In Cartridge Valves
Ordering Code / Dimensions Series C*B, Cover with Stroke Limiter

C B N

Cover Nominal Cover with Adjustment Orifice Seal Design


size X-connection screw/ series
and stroke spindle (not required
limiter for ordering)
Code Size
Code Seal
016 NG16
N NBR
025 NG25
V FPM
032 NG32
040 NG40
050 NG50 Code Orifice
063 NG63 99 Without orifice, open

M
1

For orifice recommendations, bolt and seal X Z1 C Z2 Y


kits see "Accessories" in this chapter. Orifice position

Please note: stroke limiter must not be used for shutting off the cartridge valve. Blocking the cartridge valve in closed
position can cause mechanical damage to the stroke limiter and malfunction of the valve.

Dimensions NG16 - NG25


max.L 2

Gauge port
8
L1

X Y
Orifice

Z1
B

1cm

M16

X Y
Z2

4 B

Ports Y, Z1 and Z2: O-ring recess diameter on valve body

Size B L1 L2 max. Gauge port Orifice thread Weight [kg]


NG16 65 36 72 G⅛" M6 0.9
NG25 85 45 72 G¼" M6 1.9

CE-C UK.INDD 06.01.23

8-9 Parker Hannifin Corporation


Catalogue MSG11-3500/UK 2-Way Slip-In Cartridge Valves
Dimensions Series C*B, Cover with Stroke Limiter

Dimensions NG32 - NG50

Ports Y, Z1 and Z2: O-ring recess diameter on valve body

Dimensions NG63

1cm
L2

8
L1

Gauge port

X Y

Orifice

Z1
B

X Y

Z2

4 B

Ports Y, Z1 and Z2: O-ring recess diameter on valve body

Size B L1 L2 max. Gauge port Orifice thread Weight [kg]


NG32 102 50 48 G¼" 1/16 NPT 2.91
NG40 125 60 50 G¼" 1/16 NPT 5.39
NG50 140 70 50 G¼" 1/16 NPT 8.41
NG63 180 85 65 G¼" 1/8 NPT 15.1

CE-C UK.INDD 06.01.23

8-10 Parker Hannifin Corporation


Catalogue MSG11-3500/UK 2-Way Slip-In Cartridge Valves
Ordering Code / Dimensions Series C*C, Cover f. Pilot System Mounting

C C A
1 2 3 4
Cover Nominal Cover Without Orifice / Seal Design
size for pilot auxilliary choke series
system function (not required
mounting for ordering)
Code Size
Code Seal
016 NG16
N NBR
025 NG25
V FPM
032 NG32
040 NG40
050 NG50 Code Orifice
063 NG63 99 Without orifice, open
080 NG80 00 Plug
100 NG100 NG16 to NG40
P A B T

Attention:
For NG50 and larger: 3 1 2 4
If pilot system NG06 should be used, mount adapter plate X Z1 C Z2 Y
PADA 1007/A-B/B-A or PADA 1007/A-A/B-B (NG10 to NG50 to NG100
NG06) see "Accessories" in this chapter. P A B T

For orifice recommendations, bolt and seal kits see


"Accessories" in this chapter. 3 2 1 4
X Z2 C Z1 Y
Orifice position

8
Dimensions NG16
Section A-A Section B-B Section C-C
A B T P
Gauge Gauge
port port
40

X Y Z1 Z2
5 6 1 2 4
B C

Z1

T
X B Y
65

A A
A
P

Z2
B C
79

CE-C UK.INDD 06.01.23

8-11 Parker Hannifin Corporation


Catalogue MSG11-3500/UK 2-Way Slip-In Cartridge Valves
Dimensions Series C*C, Cover f. Pilot System Mounting

Dimensions NG25 to NG40

Dimensions NG50 to NG63

CE-C UK.INDD 06.01.23

8-12 Parker Hannifin Corporation


Catalogue MSG11-3500/UK 2-Way Slip-In Cartridge Valves
Dimensions Series C*C, Cover f. Pilot System Mounting

Dimensions NG80 to NG100

8
Orifice thread
Size B L Gauge port Weight [kg]
1 2 3 4 5 6
NG16 79 1) 40 G⅛" 1.0 M5 M5 M5 M5 M5 M5
NG25 85 45 G¼" 1.9 M5 M5 M6 M6 M6 M6
NG32 102 50 G¼" 2.9 M5 M5 M6 M6 M6 M6
NG40 125 60 G¼" 5.3 M5 M5 M6 M6 M6 M6
NG50 140 70 G¼" 8.5 M6 M6 M8 M8 M8 M8
NG63 180 85 G¼" 15.3 M6 M6 M8 M8 M8 M8
NG80 Ø 250 105 G¼" 34 1/16 NPT 1/16 NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/8 NPT
NG100 Ø 300 120 G¼" 60 1/16 NPT 1/16 NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/8 NPT

1) Width 65 mm.

CE-C UK.INDD 06.01.23

8-13 Parker Hannifin Corporation


Catalogue MSG11-3500/UK 2-Way Slip-In Cartridge Valves
Ordering Code / Dimensions Series C*F, Cover with Pressure Valve

C F
1 2 3

Cover Nominal Cover with Pressure Pressure Orifice / Seal Design


size pressure range adjustment choke series
relief valve (not required
for ordering)
Code Size
016 NG16
Code Seal
025 NG25
N NBR
032 NG32
V FPM

Pressure range
Code Code Orifice
[bar]
07 75 99 Without orifice, open
10 105
17 175
21 210
2 1 3
25 250
35 350 X Z1 C Z2 Y
Orifice position
Code Adjustment
S Hand knob (standard)
A Acorn nut with lead seal

For orifice recommendations, bolt and seal kits see


"Accessories" in this chapter.

Dimensions
8 Z1 Acorn nut
with lead seal
B

X Y

Hand knob
Z2
L1 L2
L3
H

X C Y
2 1 3

Ports Z1 and Z2: O-ring recess diameter on valve body

Orifice thread
Size B H L1 L2 max. L3

NG16 65 1) 40 32.5 114 117 M5 M4 M5


NG25 85 45 42.5 102 105 M5 M5 M5
NG32 102 50 51 95 97.5 M6 M6 M6
1) Width 79 mm.
CE-C UK.INDD 06.01.23

8-14 Parker Hannifin Corporation


Catalogue MSG11-3500/UK 2-Way Slip-In Cartridge Valves
Ordering Code / Dimensions Series C*G, Cover with Pressure Valve

C G
1 2 3 4

Cover Nominal Cover with Pressure Pressure Orifice / Seal Design


size pressure range adjustment choke series
relief valve (not required
and pilot for ordering)
Code Size
system
016 NG16 mounting Code Seal
025 NG25
N NBR
032 NG32
V FPM

Pressure range
Code Code Orifice
[bar]
07 75 99 Without orifice, open
10 105 P A B T
17 175 2
21 210
25 250
3 1 4
35 350
X Z1 C Z2 Y
Code Adjustment Orifice position
S Hand knob (standard)
A Acorn nut with lead seal

For orifice recommendations, bolt and seal kits see


"Accessories" in this chapter.
Dimensions
Z1
T
Acorn nut
with lead seal 8
A
B

X Y

Hand knob
Z2
L1 L2
L3

2
A
H

X C Y
3 1 4
Ports Z1 and Z2: O-ring recess diameter on valve body

Orifice thread
Size B H L1 L2 max. L3

NG16 65 1) 40 32.5 114 117 M5 M5 M4 M5


NG25 85 45 42.5 102 105 M5 M5 M5 M5
NG32 102 50 51 95 97.5 M6 M6 M6 M6
1) Width 79 mm.
CE-C UK.INDD 06.01.23

8-15 Parker Hannifin Corporation


Catalogue MSG11-3500/UK 2-Way Slip-In Cartridge Valves
Ordering Code / Dimensions Series C*V, Cover with Shuttle Valve

Ordering code
C V A
1 2 3 4

Cover Nominal Cover with w/o Orifice / Seal Design


size shuttle additional choke series
valve option (not required
for ordering)
Code Size
016 NG16
Code Seal
025 NG25
N NBR
032 NG32
V FPM
040 NG40
050 NG50
063 NG63 Code Orifice
99 Without orifice, open
P A B T

For orifice recommendations, bolt and seal kits see 3 1 2 4


"Accessories" in this chapter.

Dimensions X Z1 C Z2 Y
Orifice position
Section A-A

4 3
1 2
A T B P
H

8
X C Y

Z1
B

X Y
A A

Z2
4 L1

Port Z2: O-ring recess diameter on valve body

Orifice thread
Size B H L1

NG16 65 86.5 85 M5 M5 M5 M5
NG25 85 91.5 85 M5 M5 M5 M5
NG32 102 96.5 102 M5 M5 M5 M5
NG40 125 106.5 125 M6 M6 M6 M6
NG50 140 126.5 140 M8 M8 M8 M8
NG63 180 141 180 M8 M8 M8 M8

CE-C UK.INDD 06.01.23

8-16 Parker Hannifin Corporation


Catalogue MSG11-3500/UK 2-Way Slip-In Cartridge Valves
Ordering Code / Dimensions Series C*W, Cover with Shuttle Valve

C W A
1 2 3 4

Cover Nominal Cover with w/o Orifice / Seal Design


size shuttle additional choke series
valve and option (not required
pilot system for ordering)
Code Size
mounting
016 NG16
Code Seal
025 NG25
N NBR
032 NG32
V FPM
040 NG40
050 NG50
063 NG63 Code Orifice
99 Without orifice, open
P A B T
3 1 2 4
For orifice recommendations, bolt and seal kits see
"Accessories" in this chapter.
X Z1 C Z2 Y

Orifice position
Dimensions

Port Z2: O-ring recess diameter on valve body

Orifice thread
Size B H L1

NG16 65 40 77.5 M5 M5 M5 M5
NG25 85 45 85 M5 M5 M5 M5
NG32 102 50 102 M5 M5 M5 M5
NG40 125 60 125 M6 M6 M6 M6
NG50 140 70 140 M8 M8 M8 M8
NG63 180 85 180 M8 M8 M8 M8

CE-C UK.INDD 06.01.23

8-17 Parker Hannifin Corporation

You might also like