www.limatherm.
com
                                                                           N-L3625
                                                                          Updated 15.07.2019
                     APPLICATION MANUAL
                             Flameproof Ex d
                    Universal Instrument Housing Type:
                    XD-SI, XD-SIwin, XD-SILwin,
   Contents:
   1. Destination.
   2. Flameproof joints.
   3. Carried out tests.
   4. Temperature classes, ambient temperature, power dissipation.
   5. Earth and protection terminals.
   6. Cover locking.
   7. Protection degree.
   8. Way of fixing.
   9. Marking.
NOTES OF SAFETY
The XD-SI, XD-SIwin, XD-SILwin series are designed to accommodate different electronic
instruments or devices. If used incorrectly it is possible that application-related dangers
may arise.
The XD-SI, XD-SIwin, XD-SILwin universal instrument housing may be used by qualified
and authorized company and people only, under strict observance of these application
manual and relevant standards, legal requirements, and, where appropriate the certificate.
Only the empty XD-SI... instrument housing is certified. When used as part of an end
product assembly, subsequent approval of the end use equipment assembly is required.
                                                                                         page 1 / 6
Limatherm S.A., ul. Tarnowska 1, 34-600 Limanowa, Poland, tel +48 18 337 98 20, fax +48 18 337 98 25
www.limatherm.com
1. DESTINATION
                                                                              N-L3625
    •     Marking                                      •  Service temperature
          2014/34/UE               IECEx                                  Tserv               Tserv
                                                    Housing type     o-ring VMQ           o-ring FKM
                                Ex db I Mb                              rubber              rubber
        I M2 Ex db I Mb
                               Ex db IIC Gb         XD-SI           -50 to +150°C        -20 to +200°C
        II 2G Ex db IIC Gb                          XD-SIwin
                               Ex tb IIIC Db                         -50 to +85°C         -20 to +85°C
        II 2D Ex tb IIIC Db                         XD-SILwin
    • Standards:                                           •     Possible zone application
    ATEX 2014/34/UE                                                 Zone             Protection Code
    EN 60079-0, EN 60079-1, EN 60079-31,                                         Ex d + Ex ia, Exd
                                                               Zone 0, Zone 20
    IEC 60079-0, IEC 60079-1, IEC 60079-31                                       +machanical separation
                                                               Zone 1, Zone 21 Ex d
                                                               Zone 2, Zone 22 Ex d
!  The empty enclosure can be used for electrical equipment designed for ambient
temperatures not exceed range -50°C to +85°C !
! An apparatus installed inside of the empty enclosure can has any lay-out, which ensures,
that in any cross-section area will be at least 40% of area free for group IIC and 20% for
group I Mb !
! A circuit breakers or contactors containing oil filling are not allowed to be installed inside
of the empty enclosure !
2. FLAMEPROOF JOINTS
Flameproof joints are designed for volume 500 < V ≤ 2000 cm3 group II C enclosures.
                                                                                            page 2 / 6
Limatherm S.A., ul. Tarnowska 1, 34-600 Limanowa, Poland, tel +48 18 337 98 20, fax +48 18 337 98 25
www.limatherm.com
                                                                            N-L3625
                               Requirements of
Lp.     Connection type                                              Achieved values
                                  60079-1
                              threads engaged ≥ 5   9
 1    M100×2 6H/6g            depth of
                                                    18,5mm
                              engagement ≥ 8 mm
                                                          6g of male thread should be
                              fit of thread                                                     6H/6g
                                                          ensured by customer
                 M20×1.5 6H                               should be ensured by
                 M24×1.5 6H   threads engaged ≥ 5   l1    customer, possible to reach:   L1     6,5
                 M25×1.5 6H                               11
                                                          should be ensured by
                              depth of
                                                          customer, possible to reach:          10mm
                              engagement ≥ 8 mm
                                                          17mm
                                                          6g of male thread should be
                              fit of thread                                                     6H/6g
      D1                                                  ensured by customer
 2    proces                                              should be ensured by
      opening                 threads engaged ≥ 5         customer, possible to reach:          5
                 M27×2 6H                           l1                                   L1
                                                          8,5
                                                          should be ensured by
                              depth of
                                                          customer, possible to reach:          10mm
                              engagement ≥ 8 mm
                                                          17mm
                                                          9
                              threads provided on
                                                          male part should be ensured           -
                              each part ≥ 5
                 ½NPTmod                                  by customer
                                                    l1                                   L1
                 ¾NPTmod                                  should be ensured by
                              threads engaged             customer, possible to reach:          5
                                                          5,0 ÷ 5,5
                                                          6g of male thread should be
                              fit of thread                                                     6H/6g
                                                          ensured by customer
                                                          should be ensured by
                 M20×1.5 6H
                              threads engaged ≥ 5   l2,   customer, possible to reach:   L2,    6,5
                 M24×1.5 6H
                                                    l3    11                             L3
                 M25×1.5 6H
                                                          should be ensured by
      D2, D3                  depth of
                                                          customer, possible to reach:          10mm
 3    conduit                 engagement ≥ 8 mm
                                                          17mm
      openings
                                                          9
                              threads provided on
                                                          male part should be ensured           -
                              each part ≥ 5
                 ½NPTmod                            l2,   by customer                    L2,
                 ¾NPTmod                            l3    should be ensured by           L3
                              threads engaged             customer, possible to reach:          5
                                                          5,0 ÷ 5,5
                                  min. length of joint
 4    Cemented joint                                   11mm
                                  10mm
NPT threads are modified to reach 5÷5,5 engaged threads and can create flameproof joint with threaded
male part with standard cutting tolerance.
Process opening can be used for mounting sensor (e.g. level, flow sensor) or thermowell.
Conduit openings can be used to equip it with appropriate certificated Ex d flameproof cable
glands, fill sealing fittings, flexible couplings or thermowells.
Each D1, D2 and D3 opening can be plugged.
                                                                                               page 3 / 6
Limatherm S.A., ul. Tarnowska 1, 34-600 Limanowa, Poland, tel +48 18 337 98 20, fax +48 18 337 98 25
www.limatherm.com
                                                                                  N-L3625
3. CARRIED OUT TESTS
a) IMPACT TEST
Enclosurew was tested for lower mechanical strength for mines area (I M2 Ex db I Mb) 4J.
b) OVERPRESSURE TEST
Enclosure was verified by overpressure static test 41 bar / 10s (reference pressure 10,07 bar) for
types XD-SI and XD-SIwin and 34 bar (reference pressure: 8,32 bar) for type XD-SILwin.
4. TEMPERATURE CLASSES, AMBIENT TEMPERATURE, MAX. POWER
     DISSIPATION
                                         Maximum power dissipation [W]
                                       For all variety of                                  For all variety of
              Temp. class T6,
                                          enclosures           Temp. class T5,      or        enclosures
   Tamb     or surface temp. 85º
                                           Position              surface temp. 100ºC           Position
                     C
                                     horizontally/vertically                             horizontally/vertically
   40ºC         ∆ 0 ≤ 40 K                 20,0 / 15,0               ∆ 0 ≤ 55 K               29,0 / 24,0
   55ºC         ∆ 0 ≤ 25 K                  11,0 / 8,5               ∆ 0 ≤ 40 K               20,0 / 15,0
   70ºC         ∆ 0 ≤ 10 K                   3,6 / 3,1               ∆ 0 ≤ 25 K               11,0 / 8,5
   85ºC            N/A                                               ∆ 0 ≤ 10 K                3,6 / 3,1
  5. EARTH AND PROTECTION TERMINALS
                                 Cable cross section
                                            2
  Place        Type                     [mm ]
                             Stranded wire    Solid wire
             Protection
  Inside                           1.5            2.5
              terminal
 Outside   Earth terminal          4.0            6.0
   6. COVER LOCKING
Cover is locked by screw with hex socked
using hex spanner with across flat 2 [mm].
                                                                                                   page 4 / 6
Limatherm S.A., ul. Tarnowska 1, 34-600 Limanowa, Poland, tel +48 18 337 98 20, fax +48 18 337 98 25
www.limatherm.com
7. PROTECTION DEGREE
                                                                           N-L3625
There are three connections of assembled device deciding about IP degree:
1 – cover,
2 – process opening,
3 – conduit openings.
                                                                                         page 5 / 6
Limatherm S.A., ul. Tarnowska 1, 34-600 Limanowa, Poland, tel +48 18 337 98 20, fax +48 18 337 98 25
www.limatherm.com
                                                                                        N-L3625
    Threaded connection             Possible                     If IP for each connection        IP of assembled
            sealing                    IP                                                              device
                                                             1              2                 3
Without sealing - standard
                                        54                                         54                  IP 54
accuracy class thread
Use of a sealant, e.g. Loctite                               68                    66                  IP 66
                                        68                                         68                  IP 68
577
Thread tightened
                                        68
with O-ring
                                                      ! ATTENTION !
              It is required min IP65 protection for instruments designed for dust zones.
              (Besides zone 22, non-conductive dust, where min IP54 protection is required)
    8. WAY OF FIXING
    9. MARKING
Limatherm label with marking is put inside the housing.
The label can be glued on the outside or inside surface, it’s up to customer.
Producer of assembled instrument should apply additional own label with the marking of complete
sensor or transfer valuable information from Limatherm’s label to instrument nameplate.
                                                                                                    page 6 / 6
Limatherm S.A., ul. Tarnowska 1, 34-600 Limanowa, Poland, tel +48 18 337 98 20, fax +48 18 337 98 25